ED06D5_17 CRYDOM | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 6

Technical content

Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. ED Series

  • DC output Solid State Relay in an Industry standard EMR plug in package
  • Ratings of 5 Amps
  • Load voltage range of 1-48 and 1-80 VDC
  • Fits standard DIN rail & PCB mountable sockets
  • LED input status indicator
  • AC or DC control
  • cUL Recognized, IEC Rated, CE & RoHS Compliant
  • Motor Controller Rated PRODUCT SELECTION Control Voltage 5 A 5 A 5-15 VDC Control ED06D5 ED10D5 18-32 VDC Control ED06C5 ED10C5 48-72 VDC Control ED06F5 ED06E5 ED06B5 ED10F5 18-36 VAC Control ED10E5 90-140 VAC Control ED10B5 AVAILABLE OPTIONS OUTPUT SPECIFICATIONS DC Output (1) Description 5 A 5 A Operating Voltage [VDC] (2) 1-48 1-80 Maximum Load Current, UL 508 Resistive, [Adc] 5 5 Maximum Load Current, IEC 60947-4-1 DC-1, DC-3 [Adc, FLA] 5 5 Maximum Load Current UL 508 Motor Controller [FLA] (3) 2.0 2.0 Minimum Load Current [mAdc] 2.5 2.5 Maximum Off-State Leakage Current @ Rated Voltage [µA] 20 20 Maximum On-State Voltage Drop @ Rated Current and 40°C [Vdc] 0.3 0.3 Maximum Surge Current (10ms) [Adc] 60 60 Maximum PWM [Hz] (4) 500 500 Series Operational Current 5: 5 Amps Control Voltage B: 90-140 VAC C: 18-32 VDC D: 5-15 VDC E: 18-36 VAC F: 48-72 VDC ED 06 C 5 Required for valid part number For options only and not required for valid part number Output Voltage 06: 1-48 VDC 10: 1-80 VDC FDE-07-01 REV. A

Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. INPUT SPECIFICATIONS (1) EDxxB5EDxxE5EDxxF5EDxxC5EDxxD5Description Control Voltage Range 5-15 VDC 18-32 VDC 48-72 VDC 18-36 VAC 90-140 VAC Minimum Turn-On Voltage 5 VDC 18 VDC 48 VDC 18 VAC 90 VAC Minimum Turn-Off Voltage 1.3 VDC 2 VDC 4 VDC 4 VAC 11 VAC Maximum Reverse Voltage 3 VDC 3 VDC 3 VDC N/A N/A Minimum Input Current [mA] 11 10.7 10.8 12 7.3 Nominal Input Impedance [ohms] 350 1.6K 4.4K 1.5K 12.5K GENERAL SPECIFICATIONS (1) ParametersDescription Dielectric Strength, Input/Output (50/60Hz) 2500 Vrms Minimum Insulation Resistance (@ 500 V DC) 10 9 Ohms Maximum Capacitance, Input/Output 10 pF Ambient Operating Temperature Range -30ºC to 80ºC Ambient Storage Temperature Range -40ºC to 125ºC Weight (typical) 0.71 oz. (30 g) Maximum Humidity 85% non-condensing Housing Material PBT 30% GF, UL94 V-0 Terminals Material Copper w/Sulfamet Nickel finish GENERAL NOTES 1) All parameters at 25°C unless otherwise specified. 2) Maximum Rated voltage for ED06xx is 60 VDC and 100 VDC for ED10xx 3) Maximum Motor Controller current is 1.5 FLA for EDxxB5 and EDxxE5 4) PWM does not apply to EDxxB5 and EDxxE5 THERMAL DERATE INFORMATION 6.0 5.0 4.0 3.0 2.0 1.0 10 20 30 40 50 60 70 80 Ambient Temperature (ºC) Load Current (Amps) DERATING CURVE: EDxxx5 Maximum Turn-On Time [msec] (4)

Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. Above curve is based on a minimum spacing between parts of 16mm. Maximum current @ 0mm spacing is 3A. Derating Value: ED06x5, D10x5 = 0.125A per mm Derating based on Relay air gap: Example: 10mm spacing with a ED06D5 SSR 1.- Subtract spacing from the minimum required spacing of the part (16mm) to get the correction value. 16-10=6 2.- Multiply air gap derating value found above with correction value. 0.125 x 7 = 0.75A Now using this final number we can figure out what the maximum current the relay can carry with 10mm spacing @ 60°C Ambient. 3.- using the Ambient Derating Curve above find the current for the 5A model @ 60°C. In this case that calue is 2.5A. 4.- Subtract the value above (0.75A) from 2.5A. 2.5-0.75 = 1.75A The maximum current you can switch with the ED06D5 with a 10mm air gap between relays @ 60°C ambient is 1.75A WIRING DIAGRAM -VDC +VDC LED 5/A2 1/A1 Control Circuit -VDCLOAD A LOAD B +VDC LOAD CAN BE WIRED IN POSITION A or B

Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. AGENCY APPROVALS Designed in accordance with the requirements of IEC 62314 IEC 61000-4-2 : Electrostatic Discharge Level 1 – Criteria A IEC 61000-4-4 : Electrically Fast Transients Level 2 – Criteria B IEC 61000-4-5 : Electrical Surges Level 3 – Criteria B E116949 ACCESSORIES DIN Rail Mountable Socket Part no.: DRSED Fingersafe IP10 DIN rail mountable socket to mount ED series relays onto standard 35 mm DIN rail. Rated at 250 V AC/DC, 12 Amps. The DRSED includes M3 Combo screws. PC Board Mountable Socket Part no.: PCBSED PC Board mountable socket for ED series relays. Rated at 250 V AC/DC, 12 Amps. Suggested Pin-out hole diameter: 1.0 mm ED Series Accessories DRSED PCBSED MECHANICAL SPECIFICATIONS Tolerances: ±0.02 in / 0.5 mm All dimensions are in: inches [millimeters] .99 [25.0] 1.10 [27.9] .02 [0.5] .82 [20.8] .24 [6.1] .19 [4.8] .21 [5.3] .20 [5.1] 1.47 [37.4] DC Output: 5 Amps AC Control: B, E suffix DC Output: 5 Amps AC Control: C,D & F suffix .12 [3.0] .10 [2.5] .39 [9.9] 1.14 [29.0] .50 [12.7] .30 [7.6] Rev. 081017 ECN 20296

Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / 危险 HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH.

  • Disconnect all power before installing or working with this equipment.
  • Verify all connections and replace all covers before turning on power. Failure to follow these instructions will result in death or serious injury. RIESGO DE DESCARGA ELECTRICA O EXPLOSION.
  • Desconectar todos los suministros de energia a este equipo antes de trabajar con este equipo.
  • Verificar todas las conexiones y colocar todas las tapas antes de energizer el equipo. El incumplimiento de estas instrucciones puede provocar la muerte o lesiones serias. RISQUE DE DESCHARGE ELECTRIQUE OU EXPLOSION
  • Eteindre toutes les sources d'énergie de cet appareil avant de travailler dessus de cet appareil
  • Vérifier tous connections, et remettre tous couverts en olace avant de mettre sous De non-suivi de ces instructions provoquera la mort ou des lésions sérieuses sérieuses. GEFAHR EINES ELEKTRISCHE N SCHLAGES ODER EINER EXPLOSION.
  • Stellen Sie jeglichen Strom ab, der dieses Gerät versorgt, bevor Sie an dem Gerät Arbeiten durchführen
  • Vor dem Drehen auf Energie alle Anschlüsse überprüfen und alle Abdeckungen ersetzen. Unterlassung dieser Anweisungen können zum Tode oder zu schweren Verletzungen führen. 存在电击、 爆炸或电弧 闪烁危险
  • 在操作此设 备之前请先 关闭电源。 若不遵守这些说明, 可能会导致严重的 人身伤害甚至死亡。 RISCHIO DI SCOSSA ELETTRICA O DELL’ESPLOSIONE.
  • Spenga tutta l'alimentazione che fornisce questa apparecchiatura prima di lavorare a questa apparecchiatura
  • Verificare tutti i collegamenti e sostituire tutte le coperture prima dell’accensione L'omissione di queste istruzioni provocherà la morte o lesioni serie WARNING / AVERTISSEMENT / WARNUNG /ADVERTENCIA / AVVERTENZA / 警告 RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE
  • The product's side panels may be hot, allow the product to cool before touching.
  • Follow proper mounting instructions including torque values.
  • Do not allow liquids or foreign objects to enter this product. Failure to follow these instructions can result in serious injury, or equipment damage. RISQUE DE DOMMAGE MATERIEL ET DE SURCHAUFFE DU BOITIER
  • Les panneaux latéraux du produit peuvent être chauds. Laisser le produit refroidir avant de le toucher.
  • Respecter les consignes de montage, et notamment les couples de serrage.
  • Ne pas laisser pénétrer de liquide ni de corps étrangers à l'intérieur du produit. Le non-respect de cette directive peut entraîner, des lésions corporelles graves ou des dommages matériels. Die Nichtbeachtung dieser Anweisung kann Körperverletzung oder Materialschäden zur Folge haben. GEFAHR VON MATERIALSCHÄDEN UND GEHÄUSEERHITZUNG
  • Die Seitenwände können heiß sein. Lassen Sie das Produkt abkühlen, bevor Sie es berühren.
  • Beachten Sie die Montageanweisungen,
  • Führen Sie keine Flüssigkeiten oder Fremdkörper in das Produkt ein. Si no se respetan estas precauciones pueden producirse graves lesiones, daños materiales. RIESGO DE DAÑOS MATERIALES Y DE SOBRECALENTAMIENTO DE LA UNIDAD
  • Los paneles laterales del producto pueden estar calientes. Esperar que el producto se enfríe antes de tocarlo.
  • Respetar las instrucciones de montaje, y en particular los pares de apretado.
  • No dejar que penetren líquidos o cuerpos extraños en el producto. 如不能正确执行这些操作说明, 极有可能造成严重人体伤害或者设备的损坏。 材料损坏和高温外壳的危险性
  • 产品的一侧面板可能很热,在其冷却前请 不要触碰。
  • 遵照正确的安装说明,包括扭矩值。
  • 请勿让液体及其他异物进入本产品。 La mancata osservanza di questa precauzione può causare gravi rischi per l'incolumità personale o danni alle apparecchiature. RISCHIO DI DANNI MATERIALI E D'INVOLUCRO CALDO
  • I pannelli laterali dell'apparecchio possono scottare; lasciar quindi raffreddare il prodotto prima di toccarlo.
  • Seguire le istruzioni di montaggio corrette.
  • Non far entrare liquidi o oggetti estranei in questo apparecchio.

Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. ANNEX - ENVIRONMENTAL INFORMATION The environmental information disclosed in this annex including the EIP Pollution logo are in compliance with People’s Republic of China Electronic Industry Standard SJ/T11364 – 2006, Marking for Control of Pollution Caused by Electronic Information Products. Part Name Toxic or hazardous Substance and Elements Lead Mercury Cadmium Hexavalent Polybrominated Polybrominated (Pb) (Hg) (Cd) Chromium (Cr (VI)) biphenyls (PBB) diphenyl ethers (PBDE) Semiconductor die Solder 附件 - 环保信息 此附件所标示的包括电子信息产品污染图标的环保信息符合中华人民共和国电子行业标准 SJ/T11364 - 2006, 电子信息产品污染控制标识要求。 有毒有害物质或元素件部 名称 铅 汞 镉 六价铬 多溴联苯 多溴二苯醚 (Pb) (Hg) (Cd) (Cr (VI)) (PBB) (PBDE) 半导体芯片 焊接点