  • DC output Solid State Relay in an Industry standard EMR plug in package
  • Ratings of 5 & 10 Amps
  • Load voltage range of 1-48, 1-80 and 1-100 VDC
  • Fits standard DIN rail & PCB mountable sockets
  • LED input status indicator
  • AC or DC control
  • cUL Recognized, IEC Rated, CE & RoHS Compliant
  • Motor Controller Rated
  • Battery Management Systems
  • Backup Power Supplies
  • Valves
  • Vending Equipment
  • Lighting control
  • Medical Equipment
  • Test Equipment Sensata | Crydom ED Series DC Output Plug-in Solid State Relays are designed to replace industry standard 12 x 29 mm plug-in Electromechanical Relays, offering substantial performance advantages over traditional EMR switching solutions in many applications. Available in SPST N.O. configuration, the ED Series offer output ratings of 5 or 10 Amps at 1 to 100 VDC, and they are UL 508 recognized, IEC rated and CE compliant. PRODUCT SELECTION

www.sensata.comCopyright © 2021 Sensata Technologies, Inc. Input (1) Description EDxxD5 ED10D10 EDxxC5 ED10C10 EDxxF5 EDxxE5 EDxxB5 Control Voltage Range 5-15 VDC 5-15 VDC 18-32 VDC 18-32 VDC 48-72 VDC 18-36 VAC 90-140 VAC Minimum Turn-On Voltage 5 VDC 5 VDC 18 VDC 18 VDC 48 VDC 18 VAC 90 VAC Minimum Turn-Off Voltage 1.3 VDC 1.3 VDC 2 VDC 2 VDC 4 VDC 4 VAC 11 VAC Maximum Reverse Voltage 3 VDC 3 VDC 3 VDC 3 VDC 3 VDC N/A N/A Minimum Input Current [mA] 11 12 10.7 8 10.8 12 7.3 Nominal Input Impedance [ohms] 350 350 1.6K 3K 4.4K 1.5K 12.5K General (1) Description Parameters Dielectric Strength, Input/Output (50/60Hz) 2500 Vrms Minimum Insulation Resistance (@ 500 VDC) 109 Ohms Maximum Capacitance, Input/Output 10 pF Ambient Operating Temperature Range -30ºC to 80ºC Ambient Storage Temperature Range -40ºC to 125ºC Weight (typical) 0.71 oz. (30 g) Maximum Humidity 95% non-condensing Housing Material PBT 30% GF, UL94 V-0 Terminals Material Copper w/Sulfamate Nickel finish DC Output (1) Description 5 A 5 A 10 A Operating Voltage [VDC] 1-48 1-80 1-100 Maximum Load Current @ 40°C [ADC] (2) 5 5 10 Maximum Load Current UL 508 Motor Controller [FLA] (3) 2.0 2.0 N/A Minimum Load Current [mAdc] 2.5 2.5 2.5 Maximum Off-State Leakage Current @ Rated Voltage [μA] 20 20 20 Maximum On-State Voltage Drop @ Rated Current and Maximum Surge Current (10ms) [Adc] 60 60 80 Maximum PWM [Hz] (4) 500 500 25 SPECIFICATIONS

www.sensata.comCopyright © 2021 Sensata Technologies, Inc. WIRING DIAGRAM MECHANICAL SPECIFICATIONS Tolerance: ±0.02 in / 0.5 mm All dimensions are in millimeters [inches] THERMAL DERATE INFORMATION EDxxx5 ED10x10 Single unit, distance to adjacent components ≥ 16 mm Multiple units, no minimum spacing between components

www.sensata.comCopyright © 2021 Sensata Technologies, Inc. ORDERING OPTIONS Example : ED06C5 Family ED Operating Voltage 06 : 1-48 VDC 10 : 1-80 VDC (for 5 Amps) 1-100 VDC (for 10 Amps) Control Voltage B : 90-140 VAC (5 Amps only) C : 18-32 VDC D : 5-15 VDC E : 18-36 VAC (5 Amps only) F : 48-72 VDC (5 Amps only) Rated Load Current 5 : 5 Amps 10: 10 Amps ED 06 C 5 ACCESSORIES ED Series Accessories Required for valid part number For options only and not required for valid part number

+1 (877) 502 5500 sales.crydom@sensata.com Europe, Middle East & Africa +44 (1202) 416170 ssr-info.eu@sensata.com Asia Pacific sales.isasia@list.sensata.com China +86 (21) 2306 1500 Japan +81 (45) 277 7117 Korea +82 (31) 601 2004 India +91 (80) 67920890 Rest of Asia +886 (2) 27602006 ext 2808 www.sensata.com CONTACT USCopyright © 2021 Sensata Technologies, Inc. Sensata Technologies, Inc. (“Sensata”) data sheets are solely intended to assist designers (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, valuation, and judgment in designing Buyer’s systems and products. Sensata data sheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements, improvements, and other changes to its data sheets or components without notice. Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE OF THE DATA SHEETS, EXPRESS, IMPLIED, OR STATUTORY , INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY , FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATA SHEETS OR USE THEREOF. All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY , AND SAFETY-ELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA Rev. 06/01/2021 ECN 21137 FDE-07-01 Rev. B WARNINGS RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE

  • The product’s side panels may be hot, allow the product to cool before touching
  • Follow proper mounting instructions including torque values
  • Do not allow liquids or foreign objects to enter this product Failure to follow these instructions can result in serious injury, or equipment damage. HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH
  • Disconnect all power before installing or working with this equipment
  • Verify all connections and replace all covers before turning on power Failure to follow these instructions will result in death or serious injury. GENERAL NOTES (1) All parameters at 25°C unless otherwise specified. (2) See derating curves (3) Maximum Motor Controller current is 1.5 FLA for EDxxB5 and EDxxE5 (4) PWM does not apply to EDxxB5 and EDxxE5 AGENCY APPROVALS & CERTIFICATIONS Pilot Duty Rated C300 IEC 61000-4-2 : Electrostatic Discharge Level 3 – Criteria A IEC 61000-4-4 : Electrically Fast Transients Level 3 – Criteria B IEC 61000-4-5 : Electrical Surges Level 3 – Criteria A (5 Amps only)