Features

  • Provides motor overload, ground fault and short-circuit protection. When used in circuits subject to surge currents such as those caused by motors, transformers and other inductive components, these fuses can be sized close to full load amps to give maximum overcurrent protection.
  • Permits the use of smaller and less costly switches. The time-delay feature makes it possible to use fuse amp ratings which are much smaller than those of non time-delay fuses. Considerable cost saving occurs by permitting the use of smaller size switches, panels and fuses themselves.
  • Provides a higher degree of short-circuit protection (greater current limitation) in circuits in which surge currents or temporary overloads occur.
  • Helps protect motors against burnout from overloads.
  • Gives motor running back-up protection to motors without extra costs. Dimensions (inches) Carton Quantity and Weight Carton W eight per Carton Amps Quantity lbs kg 1-15 10 0.40 0.18 17.5-30 10 0.50 0.28 35-60 10 3.10 1.41
  • Helps protect motors against burnout from single phasing on three-phase systems.
  • Simplifies and improves blackout prevention (selective coordination).
  • Dual-element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high-performance, short-circuit and overload protection.
  • The overload element provides protection against low level overcurrent of overloads and will hold an overload which is five times greater than the amp rating of the fuse for a minimum of ten seconds. Catalog Numbers (amps) ECSR1 ECSR7 ECSR17.5 ECSR45 ECSR2 ECSR8 ECSR20 ECSR50 ECSR3 ECSR9 ECSR25 ECSR60 ECSR4 ECSR10 ECSR30 ECSR5 ECSR12 ECSR35 ECSR6 ECSR15 ECSR40

Class RK5 600Vac, 1 to 60A Dual-Element, Time-Delay Fuses Form No. ESCR 1-60 Page 2 of 2 Data Sheet #1317 0109 BU-SB08453 Current Limitation Curves Time-Current Characteristic Curves– Average Melt The only controlled copy of this document is the electronic read-only version maintained by Cooper Bussmann. All other copies o f this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical informat ion that will help the end user with design applications. Cooper Bussmann reserves the right, without notice, to change design or construction of any prod ucts and to discontinue or limit distribution of any products. Cooper Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. Class R Fuse Blocks (600V) Catalog Data (Clip Retaining Spring Standard, Suffix “R”) Fuse Reducers For Class R Fuses Equipment Desired Fuse Catalog Number Fuse Clips (Case) Size (Pairs) 600V 60A 30A No. 663-R 100A 30A No. 216-R 60A No. 616-R 200A 60A No. 626-R Terminal Type (Suffix No.) Screw Box Lug Basic with with Catalog — Pres. — Clip Amps Poles Number Plate Cu only 1 1 R60030-1 SR PR CR — to 2 R60030-2 SR PR CR COR 30 3 R60030-3 SR PR CR COR 31 1 R60060-1 — — CR — to 2 R60060-2 — — CR — 60 3 R60060-3 — — CR —