ECX-34Q ECS | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 1

Technical content

Applications: X Automotive X Medical (Non Life sustaining) X COTS X Industrial X Navigation X Test Equipment PARAMETERS CONDITIONS MIN TYP MAX ECX-34Q OPERATING CONDITIONS / ELECTRICAL CHARACTERISTICS UNITS First Year Aging Operating Temperature Storage Temperature Shunt Capacitance Motional Capacitance Temperature Coefficient Frequency FO Frequency Tolerance @ +25°C Load Capacitance Drive Level Equivalent Series Resistance Turnover Temperature Specify in P/N DL Co +25°C ±3°C S Option ± 20 0.5 80K +30 -0.040 ± 3 +125 +125 +20 -0.028 -40 -55 32.768 12.5 0.1 +25 -0.034 1.1 1.13.5 KHz ppm pF µW Ω ppm/°C² pF fF ppm TOP, BOTTOM, SIDE VIEWS & LAND PATTERN PART NUMBERING GUIDE: Example ECS-.327-12.5-34QS-TR X RoHS Compliante( 2011/65/EU) X MSL: 1 X Lead Finish: Au X AEC-Q200 Qualified X TS16949 certified production X PPAP supported ECS - Frequency Abbreviation - Load Capacitance - Package Type - Tolerance - Operating Temp Range - Packaging .327 = 32.768 KHz 12.5 = 12.5 pF 9 = 9 pF 7 = 7 pF 6 = 6 pF -34Q = ECX-34Q -TR = Tape & Reel 3K/Reel N = -40 ~ +85°C S = -40 ~ +125°C Blank = ±20 ppm C = ±10 ppm +25