Advanced Power Technologies ECLIPSE Monitor With ConfidenceTM  Real-Time Loading Prediction  Automatic E-mail Notifications  Integrated Condition Based Assessment for LTCs  Analog and Digital Input Data Concentrator  Real-Time “Loss-of-Life” Calculations  Automatic LTC Voltage Control  No Calibration Required, Ever A Platform for Complete Power Transformer Monitoring TM Complete Temperature Monitoring Plus:  Direct Fiber Winding Temperature  Built-In Annunciator  GIC Core Saturation Detection  Programmable Function Buttons  Ethernet SCADA Communications  Web-Based GUI Integrates Easily With:  Dissolved Gas Monitors  Bushing Monitors  Load Tap Changer Controls

A Complete Monitoring Platform Patented Dual-Algorithm LTC Condition MonitoringTM Up to 8 Analog Inputs Up to 45 Digital Inputs Patented Sensorless LTC Position MonitoringTM Monitor With Flexibility Patented Load Pickup CoolingTM Ethernet Communications Up to12 Aux CT Inputs

8 Relay Outputs

Up to 8 Direct Fiber Winding Inputs  User Programmable Names & Targets  Events Log with User Selected Events  Time Synchronization via DNP GIC Detection & Mitigation  Quantifiable Detection of Core Saturation  3 Levels of Alarm: Minor, Major, & Critical  Large Split-Core Hall-Effect Sensor - Accommodates up to a 4 inch bus bar U.S. & Foreign Patents Pending QuickMathTM QuickMathTM allows you to take full control of your mon- itoring through easily programmable logic. - Math Functions: +, - , x, ÷, ex, ln x, yx, x2, √, 1/x, ( ) - Perform Comparisons: =, >, <, ≥, ≤, ≠ - Program Your Own Condition-Based Assessment Criteria Including Loss of Life. - Automatic LTC Voltage Control - Create Your Own Set Points - Up to 16 User Equations - Up to 32 Comparison Evaluations - Include the Following Directly into QuickMath: Liquid and Winding Temperatures Analog Inputs Aux CT Inputs Constants Test Mode  Interactively test set points using temperature and current ramps Event and Data Logging Data Concentrator Collect data around your transformer for use in QuickMathTM equations, or simply communicate it back to SCADA TM E-mail Notifications  Receive e-mail notifications for user-customizable events Up to 4 Temperature Probes

Monitor EVERYTHING related to Transformer Health, including Dissolved Gas Analysis Data, Moisture, Bushing Monitor Health and more. Use that data directly in QuickMathTM equations, communicate it back to SCADA, or simply view it through real-time remote access via a Browser-Based GUI. Ethernet Simultaneously Supports  DNP 3.0 or MODBUS TCP/IP  Automatic E-Mail Notifications  Secure HTML Browser-Based GUI Access for:  Data logging and Event Data  Annunciation  Settings View/Edit  File Transfer Advanced Power Technologies Real-Time Winding Hotspot Permits Real-Time Dynamic Loading  No calibration or maintenance  High dielectric strength  Fired Phosphor Tipped Fiber  Rated for use at 765 kV  Compatible with existing Phosphor tip fiber installs  Up to 8 fiber capable Please see the ECLIPSE DFWT Datasheet for more details Visualize Your Transformer’s Health Web-Based GUI Direct Fiber Winding Temps Built-In Function Buttons The 8 built-in function buttons allow replacement of switches normally found in the transformer control cabinet for manual fan or tap chang- er control Comprehensive LTC Condition Based Assessment Apply: Dual-Algorithm LTC Condition MonitoringTM along with Sensorless LTC Position MonitoringTM for comprehensive LTC Condition Monitoring. The true value of this feature is realized through reliable predictive maintenance of your LTCs Additional Communication Options  Dedicated Fiber for DNP 3.0 or MODBUS  Wired RS-485 for DNP 3.0 or MODBUS  RS-232 Serial Communications Browser-Based Graphical User Interface For Monitoring, Annunciation, Settings, File Transfer, and Data Log Ethernet

Enclosure & Dimensions: 8.028 W x 4.882 H x 6.40 D Alodyne Aluminum Front Panel Dimensions: 8.378 W x 5.686 H Power Supply Input Operating Range: 38 VDC to 290 VDC or 120 VAC +/- 10%, 10 Watts Max Operating Temperature Range: -50 °C to +85 °C, 95% Relative Humidity (non condensing) Temperature Measurement Accuracy: Avg error over entire measurement range ± 1 °C. Absolute error at any temperature ± 1.5 °C for temperatures within the range of 23°C - 160°C. Below 23 ˚C the error is ± 3.5 °C. Output Contact Rating: 30 amps make for 250 msec, 8 amps continuous at 250VAC. Optically Isolated Inputs: Operates from 38 to 290 VDC or 24 VAC to 260 VAC. External wetting voltage required. Alarm Contact Rating: 0.4 amp continuous at 290 VDC (NEMA), 0.15 amp continuous at 290 VDC (Panel) Analog Output: Selectable, 0 to 1 mA or 4 to 20 mA. Maximum load 10,000 Ohms (0 to 1mA), 510 Ohms (4 to 20 mA). Analog Input: 0 to10 VDC or -5 to +5 VDC, Accuracy +/- 1% Auxiliary CT Inputs: 0 to 50 Amps RMS ± 3.5 % of full scale, High-Speed Channels can derive up to the 8th Harmonic Communications Interfaces: Front Panel Mounted RS-232 DB-9 Null Modem Interface Ethernet: 10/100 Base-T metallic interface with transformer isolation of 1,500 Volts AC RMS in accordance with IEEE/ANSI 802.3 Current Measurement Range: 0 to 50 A www.AdvPowerTech.com

215 State Route 10, Building 2

Randolph, NJ 07869 Phone: (973) 328-3300 Fax: (973) 328-0666 Surge Withstand/Fast Transient: Relay outputs and station battery inputs: ANSI C37.90.1 EMI Withstand: ANSI C37.90.2 Electrostatic Discharge: IEC 801-2 Rev. 20150930 Copyright 2015 Advanced Power Technologies, LLC U.S. Patent No.: 6222714, 6714022, 7323852, 7417411, 8260472, 8274769, 9018962 and Patents Pending