5W Ultraminiature Encapsulated Switching Power Supplies E C A - 5 s e r i e s WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE EUROPE: 353 51 561060 ASTRODYNE PACIFIC: 886-2-26983458 Model Number Output Voltage Output Amps(max) (pk) SINGLE OUTPUT - PCB Mount ESCA-5000 3.3 VDC 1.25A 1.56A ESCA-5001 5 VDC 1A 1.5A ESCA-5002 12 VDC 0.42A 0.63A ESCA-5003 15VDC 0.33A 0.5A ESCA-5005 24VDC 0.23A 0.35A SINGLE OUTPUT - Chassis Mount ESCC-5000 3.3 VDC 1.25A 1.56A ESCC-5001 5 VDC 1A 1.5A ESCC-5002 12 VDC 0.42A 0.63A ESCC-5003 15VDC 0.33A 0.5A ESCC-5005 24VDC 0.23A 0.35A SINGLE OUTPUT - DIN Rail Mount ESCC-5000/DRL 3.3 VDC 1.25A 1.56A ESCC-5001/DRL 5 VDC 1A 1.5A ESCC-5002/DRL 12 VDC 0.42A 0.63A ESCC-5003/DRL 15VDC 0.33A 0.5A ESCC-5005/DRL 24VDC 0.23A 0.35A DUAL OUTPUT - PCB Mount EDCA-5006 +/-12VDC +/-0.21A +/-0.26A EDCA-5007 +/-15VDC +/-0.17A +/-0.21A DUAL OUTPUT - Chassis Mount EDCC-5006 +/-12VDC +/-0.21A +/-0.26A EDCC-5007 +/-15VDC +/-0.17A +/-0.21A DUAL OUTPUT - DIN Rail Mount EDCC-5006/DRL +/-12VDC +/-0.21A +/-0.26A EDCC-5007/DRL +/-15VDC +/-0.17A +/-0.21A Universal 85-265VAC Input High Efficiency Improved EMI Performance 3000V Isolation Single and Dual Outputs UL60950-1, EN60950-1 & IEC60950-1

5W Ultraminiature Medical Grade Encapsulated Switchers E M A - 5 s e r i e s WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE EUROPE: 353 51 561060 ASTRODYNE PACIFIC: 886-2-26983458 Model Number Output Voltage Output Amps(max) (pk) SINGLE OUTPUT - PCB Mount ESMA-5000 3.3 VDC 1.25A 1.56A ESMA-5001 5 VDC 1A 1.5A ESMA-5002 12 VDC 0.42A 0.63A ESMA-5003 15VDC 0.33A 0.5A ESMA-5005 24VDC 0.23A 0.35A SINGLE OUTPUT - Chassis Mount ESMC-5000 3.3 VDC 1.25A 1.56A ESMC-5001 5 VDC 1A 1.5A ESMC-5002 12 VDC 0.42A 0.63A ESMC-5003 15VDC 0.33A 0.5A ESMC-5005 24VDC 0.23A 0.35A SINGLE OUTPUT - DIN Rail Mount ESMC-5000/DRL 3.3 VDC 1.25A 1.56A ESMC-5001/DRL 5 VDC 1A 1.5A ESMC-5002/DRL 12 VDC 0.42A 0.63A ESMC-5003/DRL 15VDC 0.33A 0.5A ESMC-5005/DRL 24VDC 0.23A 0.35A DUAL OUTPUT - PCB Mount EDMA-5006 +/-12VDC +/-0.21A +/-0.26A EDMA-5007 +/-15VDC +/-0.17A +/-0.21A DUAL OUTPUT - Chassis Mount EDMC-5006 +/-12VDC +/-0.21A +/-0.26A EDMC-5007 +/-15VDC +/-0.17A +/-0.21A DUAL OUTPUT - DIN Rail Mount EDMC-5006/DRL +/-12VDC +/-0.21A +/-0.26A EDMC-5007/DRL +/-15VDC +/-0.17A +/-0.21A Universal 85-265VAC Input High Efficiency Improved EMI Performance 4000V Isolation Single and Dual Outputs UL60601, EN60601-1 & IEC60601-1

5W Ultraminiature Encapsulated Switching Power Supplies E C A - 5 s e r i e s WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE EUROPE: 353 51 561060 ASTRODYNE PACIFIC: 886-2-26983458 INPUT SPECIFICATIONS Input Voltage Range 90-264 VAC Frequency Range 47-63 Hz Inrush Current, typ: 20A@100V, 40A@200V Input * OUTPUT SPECIFICATIONS Voltage and Current See Selection Chart Load Regulation (20%-FL) Singles: +/- 3%, Duals: +/- 3% Line Regulation Singles +/- 0.1~1%, typ Duals +/- 0.3~1%, typ Cross Regulation (Duals) 2% Preset Accuracy 1% DC Voltage Adjust (typ) +/- 10% of FS (Primary) Temperature Coefficient +/-0.03%/°C Ripple/Noise 100mV Pk-Pk, typ Over Voltage Protection Clamp, 130-150% * Over Temp. Protection Latching, Cool and Repower Short Circuit Protection Continuous, self-recovering Hold Up Time 20 mS, typ GENERAL SPECIFICATIONS Input-Out Isolation 3KVAC, (4KVAC Medical) I/P-Ground 2500VAC O/P-Ground 1000VAC Efficiency 75%~78%, typ Switching Frequency 100Khz, (fixed, typical) PHYSICAL SPECIFICATIONS Size PCB Mount 2.28L” x 1.77W” x 0.83H” Chassis Mount 3.77L” x 2.16W” x 1.0H” Case Material Rynite, 94V-0 Rated Construction Encapsulated. Soft Pot Weight PCB / CHA 4 oz (112g) / 8.5 oz (238g) ENVIRONMENTAL SPECIFICATIONS Oper. Temperature 0 to +70°C (See Derate) Storage Temperature -25 to +71°C * Relative Humidity 0 to + 95%, non-cond * EMC / EMI FCC/A, VDE 0871/A , CISPRB MTBF (Mil Std 217, 25°C) 180,000 Hrs * These are stress ratings. Exposure of the devices to any of these conditions may adversely affect long term reliability. Proper operation under conditions other than the standard operating conditions is neither warranteed nor implied. All specifications are typical at nominal input, full load, and 25°C unless other- wise noted Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.

5W Ultraminiature Encapsulated Switching Power Supplies E C A - 5 s e r i e s WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE EUROPE: 353 51 561060 ASTRODYNE PACIFIC: 886-2-26983458 OUTPUT DERATING CURVE MECHANICAL DIMENSIONS 0 10 20 30 40 50 60 70 100 Ambient Temperature, °C Load, % 0.12 [5.3] .XX ± 0.02 [0.508] Tolerance: Dimensions shown in inch [mm] 0.20 [5.1] 0.040 [1.02] DIA. TYP. 1.77 [45.0] 0.83 [21.0] 2.28 [57.9] 1.85 [47.0] 1.85 [47.00] Model Type / Pin# Single Dual

1 AC HI AC HI

2 AC LO AC LO

3 GND GND

8 No Pin Out Com

5W Ultraminiature Encapsulated Switching Power Supplies E C A - 5 s e r i e s WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE EUROPE: 353 51 561060 ASTRODYNE PACIFIC: 886-2-26983458 Model Type / Pin# Single Dual

1 AC LO AC LO

2 GND GND

3 AC HI AC HI

4 N/C N/C

9 N/C N/C

MECHANICAL DIMENSIONS - CHASSIS MOUNT DIN Rail mounting kit available for Chassis-mount modules, specify part # M-DRL-01. Kit includes mounting plate, DIN Rail cliip and assembly hardware. 0.350 [8.89] 0.100 [2.54] MECHANICAL DIMENSIONS - DIN RAIL