Simple Functions in DIN 48 × 48 mm-size Plug-in Temperature Controllers

  • Easy setting using DIP switch.
  • Models with two alarms added to Series, ideal for applications requiring alarms.
  • Universal-input (thermocouple/platinum resistance thermometer) models also available.
  • Clearly visible digital display with character height of 13.5 mm.
  • RoHS compliant. Refer to Safety Precautions for All Temperature Controllers. Refer to E5CS/E5CSV Operation for operating procedures. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Model Number Structure ■Model Number Legend Plug-in Models Note: A functional explanation is provided here for illustration, but models are not necessarily available for all possible combinations. Refer to Ordering Information when ordering. Examples
  • Relay control output, without alarm, thermocouple input, plug-in construction, light gray case: E5CS-RKJU-W
  • Relay control output, one alarm output, platinum resistance thermometer input, plug-in construction, light gray case: E5CS-R1PU-W 1 2 3 45 6 E5CS-@@@@U-W 1. Control Outputs R: Relay Q: Voltage for driving SSR 2. Alarm Outputs Blank: No alarm 1: 1 alarm 2: 2 alarms 3. Input KJ: Thermocouple P: Platinum resistance thermometer G: Thermistor T: Thermocouple/platinum resistance thermometer (universal-input) 4. Power Supply Voltage Blank: 100 to 240 VAC D: 24 VAC/VDC 5. Terminal Shape U: Plug-in 6. Case Color W: Light gray

Ordering Information

■List of Models Case Color: Light Gray, Thermocouple or Platinum Resistance Thermometer, Power Supply Voltage: 100 to 240 VAC Case Color: Light Gray, Thermocouple or Platinum Resistance Thermometer, Power Supply Voltage: 24 VAC/VDC Case Color: Light Gray, Thermistor or Universal-input, Power Supply Voltage: 100 to 240 VAC Note: There is no alarm output 2 mode switch. The default setting for alarm output 2 is for the upper limit alarm mode. To change the setting, change the alarm type for alarm output 2 in initial setting level 5. For details, refer to the “E5CSV/E5CS-U Digital Temperature Controller User’s Manual” (Cat. No. H140-E1-01). Case Color: Light Gray, Thermistor, Power Supply Voltage: 24 VAC/VDC ■Accessories (Order Separately) Socket without Alarm (8 Pins) Socket with Alarm (11 Pins) Protective Cover Size Type Control modes Alarms Outputs Model with thermocouple Model with platinum resistance thermometer E5CS-U 48 × 48 mm Plug-in ON/OFF or PID

0 Relay E5CS-RKJU-W E5CS-RPU-W

Voltage (for driving SSR) E5CS-QKJU-W E5CS-QPU-W

1 Relay E5CS-R1KJU-W E5CS-R1PU-W

Voltage (for driving SSR) E5CS-Q1KJU-W E5CS-Q1PU-W Size Type Control modes Alarms Outputs Model with thermocouple Model with platinum resistance thermometer E5CS-U 48 × 48 mm Plug-in ON/OFF or PID

0 Relay E5CS-RKJDU-W E5CS-RPDU-W

Voltage (for driving SSR) E5CS-QKJDU-W ---

1 Relay E5CS-R1KJDU-W E5CS-R1PDU-W

Voltage (for driving SSR) E5CS-Q1KJDU-W --- Size Type Control modes Alarms Outputs Model with thermistor Model with universal- input (thermocouple and platinum resistance thermometer) E5CS-U 48 × 48 mm Plug-in ON/OFF or PID

0 Relay E5CS-RGU-W E5CS-RTU-W

Voltage (for driving SSR) E5CS-QGU-W E5CS-QTU-W

1 Relay E5CS-R1GU-W E5CS-R1TU-W

Voltage (for driving SSR) E5CS-Q1GU-W E5CS-Q1TU-W (See note.) Relay --- E5CS-R2TU-W Voltage (for driving SSR) E5CS-Q2TU-W Size Type Control modes Alarms Outputs Model with thermistor E5CS-U 48 × 48 mm Plug-in ON/OFF or PID

0 Relay E5CS-RGDU-W

1 E5CS-R1GDU-W

Front Connecting Socket P2CF-08 Back Connecting Socket (flush mounting) P3G-08 Front Connecting Socket (with finger protection) P2CF-08-E Finger Safe Terminal Cover for P3G Y92A-48G Type Model Front Connecting Socket P2CF-11 Back Connecting Socket (flush mounting) P3GA-11 Front Connecting Socket (with finger protection) P2CF-11-E Finger Safe Terminal Cover for P3G Y92A-48G Type Model Hard Protective Cover Y92A-48B

■Ratings Note: Do not use an inverter output as the power supply. (Refer to Safety Precautions for All Temperature Controllers.) Supply voltage 100 to 240 VAC, 50/60 Hz

24 VAC, 50/60 Hz; 24 VDC

Operating voltage range 85% to 110% of rated supply voltage Power consumption 100 to 240 VAC: 5 VA

24 VAC: 3 VA, 24 VDC: 2 W

Sensor input Thermocouple: K, J, L Platinum resistance thermometer: Pt100, JPt100 Thermistor: E52-THE @@ Universal-input (thermocouple/platinum resistance thermometer): K, J, L, T, U, N, R, Pt100, JPt100 Control output Relay output SPDT, 250 VAC, 3 A (resistive load) Voltage output (for driving the SSR)

12 VDC, 21 mA (with short-circuit protection circuit)

Control method ON/OFF or 2-PID (with automatic PID parameter setting function) Alarm output SPST -NO, 250 VAC, 1A (resistive load) Setting method Digital setting using front panel keys Indication method 7-segment digital display (character height: 13.5 mm) and deviation indicators Other functions • Setting change prohibit (key protection)  Input shift  Temperature unit change (°C/°F)  Direct/reverse operation  Temperature range, Sensor switching (K/J/L, Pt100/JPt100)  Switching is performed between a thermocouple and platinum resistance thermometer for universal-input models.  Control period switching  8-mode alarm output  Sensor error detection (excluding thermistor models) Ambient operating temperature −10 to 55°C (with no condensation or icing); with 3-year guarantee: −10 to 50°C Ambient operating humidity 25% to 85% Storage temperature −25 to 65°C (with no condensation or icing)

■Characteristics Note: 1. The following exceptions apply to thermocouples.

  • U, L: ±2°C ±1 digit max.
  • R: ±3 °C ±1 digit max. at 200°C or less 2. The following exception applies to platinum resistance thermometers.
  • Input set values 1 for E5CS-U: 1% FS ±1 digit max. 3. The following exceptions apply to thermistors.
  • When the unit setting is °C, temperature indication ranges exceeding the set temperature range ±10% FS may not be accurate.
  • When the unit setting is °F, the temperature range for the input setting numbers 4 and 9 (609 to 630°F) and temperature indication ranges exceeding the set temperature range −5% FS to +10% FS may not be accurate. 4. Industrial electromagnetic environment (EN/IEC 61326-1 Table 2) Setting accuracy Thermocouple (See note 1.): (±1% of indication value or ±2 °C, whichever is greater) ±1 digit max. Platinum resistance thermometer (See note 2.): (±0.5% of indication value or ±1 °C, whichever is greater) ±1 digit max. Thermistor (See note 3.): (1% FS of indication value) ±1 digit max.Indication accuracy (ambient temperature of 23°C) Influence of temperature R thermocouple inputs: (±2% of PV or ±10°C, whichever is greater) ±1 digit max. Other thermocouple inputs: (±2% of PV or ±4°C, whichever is greater) ±1 digit max. Platinum resistance thermometer inputs: (±1% of PV or ±2°C, whichever is greater) ±1 digit max. Thermistor: (±2% FS) ±1 digit max. Influence of voltage Influence of EMS. (at EN 61326-1) Hysteresis (for ON/OFF control) 0.2% FS (0.1% FS for universal-input (thermocouple/platinum resistance thermometer) models) Proportional band (P) 1 to 999°C (automatic adjustment using auto-tuning/self-tuning) Integral time (I) 1 to 1,999 s (automatic adjustment using auto-tuning/self-tuning) Derivative time (D) 1 to 1,999 s (automatic adjustment using auto-tuning/self-tuning) Alarm output range Absolute-value alarm: Same as the control range Other: 0 to input setting range full scale (°C or °F) Alarm hysteresis: 0.2 °C or °F (fixed) Control period 2/20 s Sampling period 500 ms Insulation resistance 20 MΩ min. (at 500 VDC) Dielectric strength 2,000 VAC, 50/60 Hz for 1 min between current-carrying terminals of different polarity Vibration resistance Malfunction 10 to 55 Hz, 20 m/s2 for 10 min each in X, Y, and Z directions Destruction 10 to 55 Hz, 0.75-mm single amplitude for 2 hr each in X, Y, and Z directions Shock resistance Malfunction 100 m/s2 min., 3 times each in six directions Destruction 300 m/s2 min., 3 times each in six directions Life expectancy Electrical 100,000 operations min. (relay output models) Weight Approx. 110 g (Controller only) Degree of protection Front panel: Equivalent to IP50, Enclosure Category 2 (IEC 60529), Rear case: IP20; Terminals: IP00 Memory protection EEPROM (non-volatile memory) (number of writes: 1,000,000) EMC EMI Radiated: EN 55011 Group 1 Class A EMI Conducted: EN 55011 Group 1 Class A Radiated Electromagnetic Field Immunity: EN 61000-4-2: 4 kV contact discharge (level 2) 8 kV air discharge (level 3) RF-interference Immunity: EN 61000-4-3: 10 V/m (80-1000 MHz, 1.4-2.0 GHz amplitude modulated) (level 3)

10 V/m (900 MHz pulse modulated)

Conducted Disturbance Immunity: EN 61000 -4-6: 3 V (0.15 to 80 MHz) (level 2) Noise Immunity (First Transient Burst Noise): EN 61000-4-4 Burst Immunity: 2 kV power-line (level 3), 1 kV I/O signal-line (level 3) Surge Immunity: EN 61000-4-5: Power line: Normal mode 1 kV; Common mode 2 kV Output line (relay output): Normal mode 1 kV; Common mode 2 kV Voltage Dip/Interrupting Immunity: EN 61000-4-11 0.5 cycle, 100% (rated voltage) Approved standards UL 61010-1 (listing) CSA C22.2 No.1010-1 Conformed standards EN 61326-1 (See note 4.), EN 61010-1, IEC 61010-1

■Temperature Range Thermocouple Input Models Platinum Resistance Thermometer Input Models Thermistor Input Models (For details on Sensors, refer to E52.) Universal-input (Thermocouple/Platinum Resistance Thermometer) Models

  • Using Thermocouple Sensors, Control Mode Switch 5: OFF
  • Using Platinum Resistance Thermometers, Control Mode Switch 5: ON Input K J/L Temperature range (selected using switch) 1,000 900 800 700 600 500 400 300 200 100 999 600 500 500 400 400 300 300 (Default setting: 2) 200 200 0000000000 Setting number 01 23456789 Minimum setting unit 1°C1 °C Temperature range (selected using switch) Input JPt100/Pt100 500 400 300 200 100 −100 400 400 300 300 200 199.9 50 50.0 80 99.9 (Default setting: 3) 0 . 0 0 . 0 00000 0 . 0 −50 −20 Setting number 012 3456789 Minimum setting unit 1 °C0 . 1 °C1 °C0 . 1 °C1 °C0 . 1 °C Input G Temperature range (selected using switch) 6 kΩ (0°C) 6 kΩ (0°C) 30 kΩ (0°C) 550 Ω (200°C) 4 kΩ (200°C) 6 kΩ (0°C) 6 kΩ (0°C) 30 kΩ (0°C) 550 Ω (200°C) 4 kΩ (200°C) 500 400 300 200 100 −100 300 300 150 200 150 200 50 100 50 100 100 150 100 150 (Default setting: 1) 05 0 05 0 −50 −50 Setting number 0 123456789 Minimum setting unit 1°C I n p u t K J L T UNR 1,700 1,600 1,500 1,400 1,300 1,200 1,100 1,000 900 800 700 600 500 400 300 200 100 −100 1,700 Temperature range (selected using switch) 1,300 1,300 850 850 (Default setting: 0) 400 400 199.9 199.9 199.9 0.0 0.0 0.0 0 Setting number 0123456789 Minimum setting unit 1 °C0 . 1 °C1 °C0 . 1 °C1 °C0 . 1 °C1 °C Input Pt100 JPt100 Temperature range (selected using switch) 1,000 900 800 700 600 500 400 300 200 100 −100 850 500 400 400 (Default setting: 0) 199.9 200 199.9 200 99 99 0.00 00 .00 0 −99 −99 −99 −99 Setting number 0123456789 Minimum setting unit 1 °C0 . 1 °C1 °C0 . 1 °C1 °C The shaded value indicates the default setting status. 0 1 2 4567 The shaded value indicates the default setting status. 0 1 2 4567 The shaded value indicates the default setting status. 0 1 2 4567 The shaded value indicates the default setting status. 0 1 2 4567 The shaded value indicates the default setting status. 0 1 2 4567

External Connection Diagram Note: 1. The voltage output (12 VDC, 21 mA) is not electrically isolated from the internal circuits. When using a grounding thermocouple, do not connect output terminals 4 or 5 to ground. Otherwise, unwanted current paths will cause measurement errors. 2. Models with 100 to 240 VAC and 24 VAC/VDC are separate. Models using 24 VDC have no polarity. 3. Be sure to check the sensor type before using multi-output (thermocouple/platinum resistance thermometer) models. Nomenclature E5CS-U Plug-in Models Sensor Thermocouple (See note 3.) Platinum resistance thermometer (See note 3.) Thermistor Plug-in models Without alarms Voltage output models (See note 1.) Voltage output models (See note 1.) Voltage output models (See note 1.) Relay output models Relay output models Relay output models With alarms Relay output models Relay output models Relay output models

12 VDC,

(K, J) 100 to 240 VAC

24 VAC/VDC

(See note 2.) A B B 4 5 100 to 240 VAC (See note 2.) 4 5 100 to 240 VAC (See note 2.)

12 VDC, 21 mA

(See note 1.) Two alarm points (See note 1.) Two alarm points (See note 1.) 5 6 7 101112 Alarm output 100 to 240 VAC (See note 2.) A B B 5 6 7 101112 Alarm output 100 to 240 VAC (See note 2.) 5 6 7 101112 Alarm output 100 to 240 VAC (See note 2.) Output indicator Temperature display Alarm indicators Up Key Down key Deviation indicators Mode indicators Mode Key

Note: All units are in millimeters unless otherwise indicated. ■Controller Note: The external dimensions are the same for both models with and without alarms. 48 × 48 6.25 (7.75) 72.5 94.45 44.8 × 44.8 Mounting side-by-side (group mounting of N Controllers) 45+0.6 45+0.6 45+0.6 L Note: Use the P2CF-08 and P3G-08 Sockets for models without alarms, and use the P2CF-11 and P3GA-11 Sockets for models with alarms. 2 1 11 10 754 1 8 E5CS-U E5CS-U + Adapter for Flush Mounting (Enclosed) + Back Connecting Socket (Order Separately) (Without Alarms) Terminal Arrangement (Bottom View) Models without alarms E5CS-U + Adapter for Flush Mounting (Enclosed) + Back Connecting Socket (Order Separately) (With Alarms) Models with alarms Tightening screws48 1007 Adapter for flush mounting P3GA-11 Back Connecting Socket Panel Y92F-30 Adapter for flush mounting Tightening screws48 957 Adapter for flush mounting P3G-08 Back Connecting Socket Panel Y92F-30 Adapter for flush mounting Panel Cutout Dimensions

■Accessories (Order Separately) Note: Do not use any other types of Sockets. Doing so will adversely affect the accuracy. Applicable Thermistors Use Element Interchangeable Thermistors (E52-THE5A, E52- THE6D, and E52-THE6F) to connect to the E5CS-@GU. For details on Sensors, refer to E52. Hard Protective Cover The Y92A-48B Hard Protective Cover is available for the following applications.  To protect the set from dust and dirt.  To prevent the panel from being accidentally touched causing displacement of set values.  To provide effective protection against water droplets. 6 5 4 3 7 8 1 2 70 max. Two, 4.5-dia. holes Eight, M3.5 × 7.5 sems screws 7.8 20.3 max. 4.53 50 max. 35.4 ±0.2 Two, 4.5-dia. hole or two, M4 M3.5 27 dia. 4.9 43 5 6 12 8 7 8-pin Sockets without Alarms P2CF-08 Front Connecting Socket P3G-08 Back Connecting Socket Note: DIN Track mounting is also possible. Note: The P2CF-08-E Socket with finger protection is also available. Terminal Arrangement/ Internal Connections (Top View) Terminal Arrangement (Bottom View) Note: The Y92A-48G Finger Safe Terminal Cover is also available. Mounting Hole Dimensions 11-pin Sockets with Alarms P2CF-11 Front Connecting Socket 47 3 8.7 8765 2 1 11 10 27 dia. 4.516.3 6.2 25.645 8 7 6 5 10 11 1 2 70 max. 50 max. Two, 4.5-dia. holes Eleven, M3.5 × 7.5 sems screws 7.8 31.2 max. 4.53 35.4 ±0.2 Two, 4.5-dia. mounting holes P3GA-11 Back Connecting Socket Note: The P2CF-11-E Socket with finger protection is also available. Terminal Arrangement (Bottom View) Note: The Y92A-48G Finger Safe Terminal Cover is also available. Mounting Hole Dimensions Note: DIN Track mounting is also possible. Terminal Arrangement/ Internal Connections (Top View) 92A-48B92A-48B92A-48B

Refer to Safety Precautions for All Temperature Controllers. Refer to E5CS/E5CSV Operation for operating procedures. In the interest of product improvement, specifications are subject to change without notice. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. 2015.8 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2015 All Right Reserved.