Programmable Digital Controller E5AR-T A new High-speed, High-precision Digital Controller that is Programmable!
- Create up to 32 programs with up to 256 segments total. Coordinated operation for up to four channels with one Digital Controller. 0 . 0 1°C High resolution for Pt input. High-speed sampling at 50 ms. Settings easily made from a computer using the CX-Thermo. RoHS compliance for world-wide application. Refer to Safety Precautions for All E5@R Models. Model Number Structure ■Model Number Legend 1. Control method Blank:Standard or heating/cooling control P: Position proportional control 2. Output 1 R: NO relay output + NO relay output Q: Pulse output/current output + pulse output C: Current output + current output 3. Output 2 R: NO relay output + NO relay output Q: Pulse output/current output + pulse output C: Current output + current output 4. Auxiliary Outputs Blank:None 4: NO relay output + NO relay output E: 5 transistor outputs + 5 transistor outputs 5. Communications Blank:None 3: RS-485 communications 6. Optional function Blank:None D: 4 event inputs M: 4 event inputs + 4 event inputs 7. Input 1 B: Universal-input and 2 event inputs F: Universal-input and FB W: Universal-input and universal-input 8. Input 2 Blank:None W: Universal-input and universal-input 9. Other FLK: CompoWay/F communications Note: The above model number legend is intended as a functional description of models. Not all possible combinations of functions are available. Confirm model availability in Ordering Information when ordering. 234 5 96781 Note: Be sure to read the precautions for correct use and other precautions in the following user's manual before using the Digital Controller. E5AR/ER Digital Controller User's Manual (Cat. No. Z182)
Ordering Information
■Digital Controllers Programmable Digital Controllers Note 1: Specify the power supply specifications when ordering. Model numbers for 100 to 240 VAC are different from those for 24 VAC/VDC. 2: These models are for 100 to 240 VAC only. 3: The outputs are transistor output. 4: Only for coordinated operation. (A separate program cannot be set for each channel.) Inspection Results If an inspection report is required, it can be ordered at the same time as the Digital Controller using the following model number. Inspection Report (Order Separately) ■Accessories (Order Separately) Terminal Cover Unit Label Sheet Rubber Packing Note: The Rubber Packing is provided with the Digital Controller. Size Control type Control mode Outputs (control/transfer) Optional functions Model Auxiliary outputs (SUB) Event inputs Serial communi- cations 96 × 96 mm Basic control (1 loop) Standard control Heating and cooling control 2 (pulse + pulse/cur- rent) 4 2 None E5AR-TQ4B 2 (current + current) E5AR-TC4B 2 (pulse + pulse/cur- rent) RS-485 E5AR-TQ43B-FLK (See note 2.) 2 (current + current) E5AR-TC43B-FLK (See note 2.) 2 (pulse + pulse/cur- rent) 10 (See note 3.)
10 E5AR-TQE3MB-FLK
(See note 2.) 2 (current + current) E5AR-TCE3MB-FLK (See note 2.) 4 (pulse + pulse/cur- rent + 2 current) E5AR-TQCE3MB-FLK 2-loop control 2-loop standard control Single-loop heating and cooling control Single-loop cascade control Single-loop control with remote SP Single-loop proportional control 2 (pulse + pulse/cur- rent) 4 4 RS-485 E5AR-TQ43DW-FLK (See note 2.) 2 (current + current) E5AR-TC43DW-FLK (See note 2.) 4 (2 pulse + pulse/2 current) 10 (See note 3.)
8 E5AR-TQQE3MW-
4-loop control 4-loop standard control 2-loop heating and cooling control (See note 4.) 4 (4 current) 10 (See note 3.)
8 RS-485 E5AR-TCCE3MWW-
4 (2 pulse + pulse/2 current) E5AR-TQQE3MWW- FLK (See note 2.) Control valve control (1 loop) Single-loop position-proportional control Relay outputs (1 open, 1 closed) 4 4 None E5AR-TPR4DF Relay outputs (1 open, 1 closed) and 1 current 10 (See note 3.)
8 RS-485 E5AR-TPRQE3MF-
Terminal Cover for E5AR E53-COV14 Model Y92S-L1 Model Y92S-P4
■Ratings Note 1: Do not use an inverter output as the power supply. (Refer to Safety Precautions for All E5@R Models.) 2: The supply voltage (i.e., 100 to 240 VAC or 24 VAC/VDC) depends on the model. Be sure to specify the required type when ordering. 3: The Controller is equipped with multiple sensor input. Temperat ure input or analog input can be selected with the input type se tting switch. There is basic insulation between power supply and input terminals, power supply and output terminals, and input and output terminals. ■Input Ranges Platinum Resistance Thermometer, Thermocouple, Current, or Voltage Input Note: The shaded area indicates the setting status at the time of purchase. Supply voltage (See note 2.) CE marking 100 to 240 VAC, 50/60 Hz 24 VAC, 50/60 Hz; 24 VDCUL certification 100 to 120 VAC, 50/60 Hz Operating voltage range 85% to 110% of rated supply voltage Power consumption 22 VA max. (with maximum load) 15 VA/10 W max. (with maximum load) Sensor input (See note 3.) Thermocouple: K, J, T, E, L, U, N, R, S, B, W Platinum resistance thermometer: Pt100 Current input: 4 to 20 mA DC, 0 to 20 mA DC (including remote SP input) Voltage input: 1 to 5 VDC, 0 to 5 VDC, 0 to 10 VDC (including remote SP input) (Input impedance: 150 Ω for current input, approx. 1 MΩ for voltage input) Control output Voltage (pulse) output 12 VDC, 40 mA max. with short-circuit protection circuit (E5AR-TQQE3MW-FLK: 21 mA max.) Current output 0 to 20 mA DC, 4 to 20 mA DC; load: 500 Ω max. (including transfer output) (Resolution: Approx. 54,000 for 0 to 20 mA DC; Approx. 43,000 for 4 to 20 mA DC) Relay output Position-proportional control type (open, closed) N.O., 250 VAC, 1 A (including inrush current) Auxiliary output Relay Output N.O., 250 VAC, 1 A (resistive load) Transistor Output Maximum load voltage: 30 VDC; Maximum load current: 50 mA; Residual voltage: 1.5 V max.; Leakage cur- rent: 0.4 mA max. Potentiometer input 100 Ω to 2.5 kΩ Event input Contact Input ON: 1 kΩ max.; OFF: 100 kΩ min. No-contact Input ON: Residual voltage of 1.5 V max.; OFF: Leakage current of 0.1 mA max. Short-circuit: Approx. 4 mA Remote SP input Refer to the information on sensor input. Transfer output Refer to the information on control output. Control method 2-PID or ON/OFF control Setting method Digital setting using front panel keys or setting using serial communications Indication method 7-segment digital display and single-lighting indicator Character Height PV display: 12.8 mm; SV display: 7.7 mm; MV display: 7.7 mm Other functions Depends on model. Ambient operating temperature −10 to 55°C (with no icing or condensation) For 3 years of assured use: −10 to 50°C (with no icing or condensation) Ambient operating humidity 25% to 85% Storage temperature −25 to 65°C (with no icing or condensation) Input type Platinum resistance thermometer Thermocouple Current Voltage Name Pt100 K J T E L U N R S B W mA V Tempera- ture range (°C) 2300 1800 1300 900 800 700 600 400 200 100 −100 −200 2300.0 20 to 20 to 0 5 to 1 5 to 0 10 to 1700.0 1700.0 1800.0 1300.0 1300.0 850.0 850.0 850.0 500.0 600.0 400.0 400.0 400.0 150.00 100.0 0.0 0.0 0.0 0.0 Setting 01 23456789 1 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 Minimum setting unit (SP and alarm) 0.1°C 0.01 °C 0.1°C (Depends on scaling and number of decimal places.) Input type setting switch Set to TC.PT. Set to ANALOG W/Re 5-26 IN1 TYPE TC.PT ANALOG IN1 TYPE TC.PT ANALOG
■Characteristics Note 1: K-, T -, or N-type thermocouple at −100°C max.: ±2°C ±1 digit max. U- or L-type thermocouple: ±2°C ±1 digit max. B-type thermocouple at 400°C max.: No accuracy specification. R- or S-type thermocouple at 200°C max.: ±3°C ±1 digit max. W-type thermocouple: (±0.3% of PV or ±3°C, whichever is greater) ±1 digit max. 2: U- or L-type thermocouple: ±1°C ±1 digit R- or S-type thermocouple at 200°C max.: ±1.5°C ±1 digit 3: “EU” (Engineering Unit) represents the unit after scaling. If a temperature sensor is used, it is either °C or °F. Indication accuracy Thermocouple input with cold junction compensation: (±0.1% of PV or ±1°C, whichever is greater) ±1 digit max. (See note 1.) Thermocouple input without cold junction compensation: (±0.1% FS or ±1°C, whichever is smaller) ±1 digit (See note 2.) Analog input: ±0.1% FS ±1 digit max. Platinum resistance thermometer input: (±0.1% of PV or ±0.5°C, whichever is greater) ±1 digit max. Position-proportional potentiometer input: ±5% FS ±1 digit max. Control mode Standard control (heating or cooling control), heating/cooling control, standard control with remote SP (2-input models only), heating/cool- ing control with remote SP (2-input models only), cascade standard control (2-input models only), cascade heating/cooling control (2-input models only), proportional control (2-input models only), positi on-proportional control (control-valve control models only) Influence of temperature Thermocouple input (R, S, B, W): (±1% of PV or ±10°C, whichever is greater) ±1 digit max. Other thermocouple input: (±1% of PV or ±4°C, whichever is greater) ±1 digit max. *K thermocouple at -100°C max.: ±10°C max. Platinum resistance thermometer: (±1% of PV or ±2°C, whichever is greater) ±1 digit max. Analog input: (±1%FS) ±1 digit max. Influence of voltage Control period 0.2 to 99.0 s (in units of 0.1 s) for time-proportioning control output Proportional band (P) 0.00% to 999.99% FS (in units of 0.01% FS) Integral time (I) 0.0 to 3,999.9 s (in units of 0.1 s) Derivative time (D) 0.0 to 3,999.9 s (in units of 0.1 s) Hysteresis 0.01% to 99.99% FS (in units of 0.01% FS) Manual reset value 0.0% to 100.0% (in units of 0.1% FS) Alarm setting range −19,999 to 99,999 EU (See note 3.) (The decimal point position depends on the input type and the decimal point position setting.) Input sampling period 50 ms Insulation resistance 20 MΩ min. (at 500 VDC) Dielectric strength 2,000 VAC, 50/60 Hz for 1 min (between charged terminals of different polarities) Vibration resistance (malfunction) 10 to 55 Hz, 20 m/s 2 for 10 min each in X, Y , and Z directions Shock resistance (malfunction) 100 m/s2, 3 times each in X, Y , and Z directions Inrush current 100 to 240-VAC models: 50 A max. 24 VAC/VDC models: 30 A max. Weight Controller only: Approx. 450 g; Mounting bracket: Approx. 60 g; Terminal cover: Approx. 30 g Degree of protection Front panel: NEMA4X for indoor use; Rear case: IP20; Terminals: IP00 Memory protection Non-volatile memory (number of writes: 100,000) Applicable standards UL 61010C-1, CSA C22.2 No. 1010-1 (Power supply voltage: 100 to 120 VAC): Pollution degree 2/Overvoltage category 2 EN 61010-1 (IEC 61010-1) (Power supply voltage: 100 to 240 VAC): Pollution degree 2/Overvoltage category 2 EMC EMI: EN61326 Radiated Interference Electromagnetic Field Strength: EN55011 Group 1 Class A Noise Terminal Voltage: EN55011 Group 1 Class A EMS: EN61326 ESD Immunity: EN61000-4-2: 4 kV contact discharge (level 2) 8 kV air discharge (level 3) Electromagnetic Immunity: EN61000-4-3: 10 V/m (amplitude-modulated, 80 MHz to 1 GHz, 1.4 GHz to 2 GHz) (level 3) Burst Noise Immunity: EN61000-4-4:2 kV power line (level 3) 2 kV output line (relay output) (level 4) 1 kV measurement line, I/O signal line (level 4) 1 kV communications line (level 3) Conducted Disturbance Immunity: EN61000-4-6: 3 V (0.15 to 80 MHz) (level 3) Surge Immunity: EN61000-4-5:1 kV line to line (power line, output line (relay output)) (level 2) 2 kV line to ground (power line, output line (relay output)) (level 3) Power Frequency Magnetic Field Immunity: EN61000-4-8: 30 A/m (50 Hz) continuous field Voltage Dip/Interrupting Immunity: EN61000-4-11: 0.5 cycle, 100% (rated voltage)
■Communications Specifications ■Program Control Functions Transmission path connection Multiple points Communications method RS-485 (two-wire, half duplex) Synchronization method Start-stop synchronization Baud rate 9,600, 19,200, or 38,400 bps Transmission code ASCII Data bit length 7 or 8 bits Stop bit length 1 or 2 bits Error detection Vertical parity (none, even, odd) Block check character (BCC): CompoWay/F CRC-16: Modbus Flow control None Interface RS-485 Retry function None Communications buffer 217 bytes Communications response send wait time 0 to 99 ms, Default: 20 ms Number of programs (patterns) 32 (with 8 segments/program) Number of segments (steps) 32 (with 8 programs) Maximum number of segments 256 Segment setting method Time setting (Segment set with set point and time.) Gradient setting (Segment set with set point, gradient, and time.) Segment times 0 h 0 min to 99 h 59 min 0 min 0 s to 99 min 59 s 0 min 00.0 s to 99 min 59.9 s Alarm group num- ber specifications Number of groups 4 Setting method Set separately for each program. Reset operation Select either stopping control or fixed SP operation. Startup operation Select continuing, resetting, manual operation, run mode, or ramp back operation. PID sets Number of sets 8 Setting method Set separately for each program (automatic PID group selection also supported). Alarm SP function Select from ramp SP and target SP . Program status control Segment operation Advance, hold, and back Program operation Program repetitions and program links Wait operation Wait method Select from waiting at segment ends and always waiting. Wait width setting Wait width upper limit and lower limit set separately for each program. Setting method ON/OFF setting for each segment Time signals Number of outputs 6 Number of ON/OFF operations 3 each per output Setting method Set separately for each program. Segment outputs Number of outputs 10 Setting method ON/OFF set for each segment. Program status output Program end output (pulse width can be set) Segment number output Program startup operation PV start Select from segment 1 set point, slope-priority PV start, and time-priority PV start. Standby Standby Operation end operation Select from resetting, continuing control at final set point, and fixed SP control. Number of event inputs 10 max.
■E5AR-T (Programmable Type) E5AR-TQ4B E5AR-TC4B E5AR-TQ43B-FLK E5AR-TC43B-FLK BE DCA KJIHGF COM SUB1 SUB2 COM SUB3 SUB4 B TCPT EV1 EV2 VI + + − − KF COM
24 VAC/DC 100 to 240 VAC
depends on model. 100 to 240 VAC or 24 VAC/DC (no polarity) Auxiliary output (Relay output) Voltage output 12 V 40 mA OUT2 OUT1 Voltage output 12 V 40 mA or Current output 4 to 20 mA DC, 500 Ω max. 0 to 20 mA DC, 500 Ω max. (Switched by output type setting.) Event input (Current) (Voltage) (Resistance temperature input sensor) (Thermocouple) BE DCA KJIHGF COM SUB1 SUB2 COM SUB3 SUB4 B − 3 − − KF EV1 EV2 COM TCPTVI depends on model. 100 to 240 VAC or 24 VAC/DC (no polarity) Auxiliary output (Relay output) OUT2 Current output 4 to 20 mA DC, 500 Ω max. 0 to 20 mA DC, 500 Ω max. (Switched by output type setting.) OUT1 Current output 4 to 20 mA DC, 500 Ω max. 0 to 20 mA DC, 500 Ω max. (Switched by output type setting.) Event input (Current) (Voltage) (Resistance temperature input sensor) (Thermocouple) + + BE DCA KJIHGF COM SUB2 COM SUB4 B TCPTVI − − K EV2 COM B(+) A(−) F 100 to 240 VAC Auxiliary output (Relay output) OUT2 Voltage output 12 V 40 mA OUT1 Voltage output 12 V 40 mA or Current output 4 to 20 mA DC, 500 Ω max. 0 to 20 mA DC, 500 Ω max. (Switched by output type setting.) Event input (Current) (Voltage) (Resistance temperature input sensor) (Thermocouple) RS-485 EV1 SUB3 SUB1 BE DCA KJIHGF TCPT EV1 EV2 VI + + − − KF COM COM COM 100 to 240 VAC Auxiliary output (Relay output) OUT2 Current output 4 to 20 mA DC, 500 Ω max. 0 to 20 mA DC, 500 Ω max. (Switched by output type setting.) OUT1 Current output 4 to 20 mA DC, 500 Ω max. 0 to 20 mA DC, 500 Ω max. (Switched by output type setting.) Event input (Current) (Voltage) (Resistance temperature input sensor) (Thermocouple) B(+) A(−) RS-485 SUB1 SUB2 SUB3 SUB4 Note The power supply voltage must be 100 to 240 VAC or 24 VAC/DC for the E5AR-T to comply with CE marking requirements. The power supply voltage must be 100 to 120 VAC or 24 VAC/DC for the E5AR-T to comply with UL requirements.
E5AR-TQE3MB-FLK E5AR-TCE3MB-FLK E5AR-TQCE3MB-FLK BE DCA KJIHGF COM B ED C F VI − − K B(+) A(−) OUT2 Voltage output 12 V 40 mA OUT1 Voltage output 12 V 40 mA or Current output 4 to 20 mA DC, 500 Ω max. 0 to 20 mA DC, 500 Ω max. (Switched by output type setting.) Event input (Current) (Voltage) (Resistance temperature input sensor) (Thermocouple) Event input Auxiliary output (Transistor output) 100 to 240 VAC SUB1(B), SUB6(C) SUB2(B), SUB7(C) SUB3(B), SUB8(C) SUB4(B), SUB9(C) SUB5(B), SUB10(C) EV3(E), EV7(D) EV4(E), EV8(D) EV5(E), EV9(D) EV6(E), EV10(D) COM COM RS-485 EV1 EV2 TCPT BE DCA KJIHGF EV3(E),EV7(D) EV4(E),EV8(D) EV5(E),EV9(D) EV6(E),EV10(D) B ED C PTIV − − K − 3 F OUT2 Current output 4 to 20 mA DC, 500 Ω max. 0 to 20 mA DC, 500 Ω max. (Switched by output type setting.) OUT1 Current output 4 to 20 mA DC, 500 Ω max. 0 to 20 mA DC, 500 Ω max. (Switched by output type setting.) B(+) A(−) Auxiliary output (Transistor output) 100 to 240 VAC Event input (Current) (Voltage) (Resistance temperature input sensor) (Thermocouple) Event input SUB1(B), SUB6(C) SUB2(B), SUB7(C) SUB3(B), SUB8(C) SUB4(B), SUB9(C) SUB5(B), SUB10(C) COM COM COM RS-485 EV1 EV2 TC Note The power supply voltage must be 100 to 240 VAC or 24 VAC/DC for the E5AR-T to comply with CE marking requirements. The power supply voltage must be 100 to 120 VAC or 24 VAC/DC for the E5AR-T to comply with UL requirements. BE DCA KJIHGF TCPTVI − − G K B ED C F depends on model. 100 to 240 VAC or 24 VAC/DC (no polarity) Voltage output 12 V 40 mA OUT2 OUT1 Voltage output 12 V 40 mA or Current output 4 to 20 mA DC, 500 Ω max. 0 to 20 mA DC, 500 Ω max. (Switched by output type setting.) OUT4 Current output 4 to 20 mA DC, 500 Ω max. 0 to 20 mA DC, 500 Ω max. (Switched by output type setting.) OUT3 Current output 4 to 20 mA DC, 500 Ω max. 0 to 20 mA DC, 500 Ω max. (Switched by output type setting.) Event input (Current) (Voltage) (Resistance temperature input sensor) (Thermocouple) Event input EV3(E), EV7(D) EV4(E), EV8(D) EV5(E), EV9(D) EV6(E), EV10(D) COM Auxiliary output (Transistor output) SUB1(B), SUB6(C) SUB2(B), SUB7(C) SUB3(B), SUB8(C) SUB4(B), SUB9(C) SUB5(B), SUB10(C) COM B(+) A(−) COM EV1 EV2 RS-485
E5AR-TQ43DW-FLK (2-loop Control) E5AR-TC43DW-FLK (2-loop Control) E5AR-TQQE3MW-FLK (2-loop Control) BE DCA KJIHGF COM SUB1 SUB2 COM SUB3 SUB4 EV6 EV5 EV4 3 B E COM VI − − VI + + − − K F 100 to 240 VAC B(+) A(−) OUT2 Voltage output 12 V 40 mA OUT1 Voltage output 12 V 40 mA or Current output 4 to 20 mA DC, 500 Ω max. 0 to 20 mA DC, 500 Ω max. (Switched by output type setting.) RS-485 Event input (Current) (Voltage) (Resistance temperature input sensor) (Thermocouple) Input 2 Input 1 Auxiliary output (Relay output) EV3 TCPT TCPT BECA KJIHGF D SUB1 SUB2 SUB3 SUB4 EV6 EV5 EV4 EV3 B E VI VI + + − − K F 100 to 240 VAC (Current) (Voltage) (Resistance temperature input sensor) (Thermocouple) Input 2 Input 1 Event input Auxiliary output (Relay output) COM COM B(+) A(−) RS-485OUT2 Current output 4 to 20 mA DC, 500 Ω max. 0 to 20 mA DC, 500 Ω max. (Switched by output type setting.) OUT1 Current output 4 to 20 mA DC, 500 Ω max. 0 to 20 mA DC, 500 Ω max. (Switched by output type setting.) COM TCPT TCPT Note The power supply voltage must be 100 to 240 VAC or 24 VAC/DC for the E5AR-T to comply with CE marking requirements. The power supply voltage must be 100 to 120 VAC or 24 VAC/DC for the E5AR-T to comply with UL requirements. BECA KJIHGF D + B ED C TCV − − V I I + + − − G K F depends on model. 100 to 240 VAC or 24 VAC/DC (no polarity) Voltage output 12 V 40 mA OUT2 OUT1 Voltage output 12 V 40 mA or Current output 4 to 20 mA DC, 500 Ω max. 0 to 20 mA DC, 500 Ω max. (Switched by output type setting.) B(+) A(−) RS-485 Voltage output 12 V 40 mA OUT4 OUT3 Voltage output 12 V 40 mA or Current output 4 to 20 mA DC, 500 Ω max. 0 to 20 mA DC, 500 Ω max. (Switched by output type setting.) Event input (Current) (Voltage) (Resistance temperature input sensor) (Thermocouple) Input 2 Input 1 EV3(E), EV7(D) EV4(E), EV8(D) EV5(E), EV9(D) EV6(E), EV10(D) COM Auxiliary output (Transistor output) SUB1(B), SUB6(C) SUB2(B), SUB7(C) SUB3(B), SUB8(C) SUB4(B), SUB9(C) SUB5(B), SUB10(C) COM PT PT TC
E5AR-TCCE3MWW-FLK (4-loop Control) E5AR-TQQE3MWW-FLK (4-loop Control) E5AR-TPR4DF E5AR-TPRQE3MF-FLK BECA KJIHGF D B ED C V VI I + + − − G F OUT4 Current output 4 to 20 mA DC, 500 Ω max. 0 to 20 mA DC, 500 Ω max. (Switched by output type setting.) OUT3 Current output 4 to 20 mA DC, 500 Ω max. 0 to 20 mA DC, 500 Ω max. (Switched by output type setting.) OUT2 Current output 4 to 20 mA DC, 500 Ω max. 0 to 20 mA DC, 500 Ω max. (Switched by output type setting.) OUT1 Current output 4 to 20 mA DC, 500 Ω max. 0 to 20 mA DC, 500 Ω max. (Switched by output type setting.) B(+) A(−) RS-485 Auxiliary output (Transistor output) SUB1(B), SUB6(C) SUB2(B), SUB7(C) SUB3(B), SUB8(C) SUB4(B), SUB9(C) SUB5(B), SUB10(C) COM Event input EV3(E), EV7(D) EV4(E), EV8(D) EV5(E), EV9(D) EV6(E), EV10(D) COM (Current) (Voltage) (Resistance temperature input sensor) (Thermocouple) Input 2(K) Input 4(J) Input 1(K) Input 3(J) TCPT TCPT J, K depends on model. 100 to 240 VAC or 24 VAC/DC (no polarity) BECA KJIHGF D + B ED C G VI VI + + − − F 100 to 240 VAC B(+) A(−)OUT2 Voltage output 12 V 21 mA OUT1 Voltage output 12 V 21 mA or Current output 4 to 20 mA DC, 500 Ω max. 0 to 20 mA DC, 500 Ω max. (Switched by output type setting.) RS-485 OUT4 Voltage output 12 V 21 mA OUT3 Voltage output 12 V 21 mA or Current output 4 to 20 mA DC, 500 Ω max. 0 to 20 mA DC, 500 Ω max. (Switched by output type setting.) COM Auxiliary output (Transistor output) SUB1(B), SUB6(C) SUB2(B), SUB7(C) SUB3(B), SUB8(C) SUB4(B), SUB9(C) SUB5(B), SUB10(C) Event input EV3(E), EV7(D) EV4(E), EV8(D) EV5(E), EV9(D) EV6(E), EV10(D) COM (Current) (Voltage) (Resistance temperature input sensor) (Thermocouple) Input 2(K) Input 4(J) Input 1(K) Input 3(J) J, K TCPT TCPT BE DCA KJIHGF V C W O I − − OUT1 F K B E depends on model. 100 to 240 VAC or 24 VAC/DC (no polarity) Relay output
250 VAC 1 A
(Current) (Voltage) (Resistance temperature input sensor) (Thermocouple) Potentiometer Event input Auxiliary output (Relay output) COM COM SUB1 SUB2 SUB3 SUB4 EV3 COM EV4 EV5 EV6 PT TC OUT2 BE DCA KJIHGF B ED C PTV C W O I + + − − F K G depends on model. 100 to 240 VAC or 24 VAC/DC (no polarity) Voltage output 12 V 40 mA OUT4 OUT3 Voltage output 12 V 40 mA or Current output 4 to 20 mA DC, 500 Ω max. 0 to 20 mA DC, 500 Ω max. (Switched by output type setting.) B(+) A(−) RS-485 OUT1 Relay output (Current) (Voltage) (Resistance temperature input sensor) (Thermocouple) Potentiometer TC Event input Auxiliary output (Transistor output) COM SUB1(B), SUB6(C) SUB2(B), SUB7(C) SUB3(B), SUB8(C) SUB4(B), SUB9(C) SUB5(B), SUB10(C) EV3(E), EV7(D) EV4(E), EV8(D) EV5(E), EV9(D) EV6(E), EV10(D) COM Note The power supply voltage must be 100 to 240 VAC or 24 VAC/DC for the E5AR-T to comply with CE marking requirements. The power supply voltage must be 100 to 120 VAC or 24 VAC/DC for the E5AR-T to comply with UL requirements.
Note: All units are in millimeters unless otherwise indicated. PV SV PRG. SEG SUB1 SUB2 SUB3 SUB4 W AIT FSP OUT1 PF1 RUN/RST PF2 CMW MANU OUT2 OUT3 OUT4 RST RSP HOLD Display No. 1 Operation Indicators Bar Graph Program Status Indicators Display No. 2 Display No. 3 Level KeyFunction Key 2Function Key 1/ Run/Reset Key Mode Key Down Key Up Key Channel Indicator E5AR-T Rear PV SV PRG. SEG SUB1 SUB2 SUB3 SUB4 WAIT FSP OUT1 PF1 RUN/RST PF2 CMW MANU OUT2 OUT3 OUT4 RST RSP HOLD 120 min. 92+0.8 92+0.8 110 min. 111 Terminal cover (E53-COV14: order separately) Crimp terminal size: M3 3 2 11.5 95 110 91 × 9196
- Recommended panel thickness is 1 to 8 mm. Group mounting is not possible. (Maintain the specified mounting space between Controllers.) When two or more Controllers are mounted, make sure that the surrounding temperature does not exceed the allowable operating temperature specified in the specifica- tions. Panel Cutouts E5AR-T
■Accessories (Order Separately) Terminal Cover Unit Label Sheet Y92S-L1 Rubber Packing Y92S-P4 (for DIN96 × 96) 28.5 10.1 E53-COV14 (for E5AR) 11.8 4.8 Order the Rubber Packing separately if it becomes lost or damaged. (Refer to page 2.) The Rubber Packing can be used to achieve an IP66 degree of protection. (Deterioration, shrinking, or hardening of the rubber packing may occur depending on the operating environment. Therefore, periodic replacement is recommended to ensure the level of waterproofing specified in NEMA4. The time for periodic replacement depends on the operating environment. Be sure to confirm this point at your site. Consider one year a rough standard. OMRON shall not be lia- ble for the level of water resistance if the customer does not perform periodic replacement.) The Rubber Packing does not need to be attached if a waterproof structure is not required. In the interest of product improvement, specifications are subject to change without notice. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
- Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
- Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations.
- Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2008.12 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2008 All Right Reserved.