Greegoo Ele ctric 11.2007 http://www.greegoo.com Motor Control Device Motor protection circuit breaker No auxiliary contacts: 0 With auxiliary contacts Integrated in the circuit-breaker: 1NO+1NC 1, 2NO 2, 2NC Application voltage up to 660V, rated operation current from 0.1A to 63A. They are used for protecting motors against overload, short-circuit and phase-failure. They can also be used for starting and stopping starters for motors, and for the circuit protection in the circuit of 0.1A-63A. Technical parameter Standard power ratings of 3-phase motors 50/60Hz in category AC-3 (kW) 0.06 0.09/0.12 0.12/0.18 0.25 0.37/0.55 0.75 1.1 1.1/1.5 1.5/2.2 2.2 4/5.5 7.5 7.5 0.37/0.55 0.75 1.1/1.5 2.2 5.5/7.5 18.5 ReferenceSetting range of thermal trips (A) 0.1-0.16 0.16-0.24 0.24-0.4 0.4-0.6 0.6-1 1-1.6 1.6-2.4 2-3.2 2.4-4 3.2-5 4-6 5-8 6-10 8-13 10-16 14-20 18-25 1-1.6 1.6-2.4 2.4-4 4-6 6-10 10-16 16-25 22-32 28-40 36-52 45-63 Thermal current Ie in (A) 0.16 0.24 0.4 0.6 1.6 2.4 3.2 1.6 2.4 Magnetic tripping current (A) 1.9 2.9 4.8 7.2 120 156 190 240 300 120 190 300 380 480 600 600 Weight (kg) 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 E3VU series circuit breakers E3VU series circuit breakers are applicable for the circuit of AC 50/60Hz, rated insulation voltage 750V, rated operating E3VU13-XB00 E3VU13-XC00 E3VU13-XD00 E3VU13-XE00 E3VU13-XF00 E3VU13-XG00 E3VU13-XH00 E3VU13-NH00 E3VU13-XJ00 E3VU13-NJ00 E3VU13-XK00 E3VU13-NK00 E3VU13-XL00 E3VU13-NL00 E3VU13-XM00 E3VU13-XN00 E3VU13-XP00 E3VU16-XG00 E3VU16-XH00 E3VU16-XJ00 E3VU16-XK00 E3VU16-XL00 E3VU16-XM00 E3VU16-XN00 E3VU16-XP00 E3VU16-XQ00 E3VU16-XR00 E3VU16-KS00 E3VU13 E3VU16

Greegoo Electric 11.2007 http://www.greegoo.com Motor Control Device Application ng current from 0.1A to 63A. They are used for preventing motors from overload and short circuit. They also can be used as direct starters to start motors and switches to changeover the circuit under the normal conditions. Motor protection circuit breaker Technical parameter Reference ReferenceSetting range of thermal trips (A) 0.1-0.16 0.16-0.25 0.25-0.4 0.4-0.63 0.63-1 1-1.6 1.6-2.5 2-3.2 2.5-4 3.2-4.5 4-6.3 5-8 6.3-10 8-12.5 10-16 14-20 1-1.6 0.16 0.25 0.4 0.63 1.6 2.5 3.2 4.5 6.3 12.5 0.16 Thermal current Ie in (A) 1.6-2.5 2.5-4 4-6.3 6.3-10 8-12.5 10-16 12.5-20 16-25 22-32 6.3-10 10-16 16-25 22-32 28-40 36-50 45-63 0.25 0.4 0.63 12.5 Rated breaking capacity of short circuit 1.5 1.5 7.5 220V 380V 660V Rated voltage (V) Rated current (A) Electric life Mechanic life 660 660 660 5000 5000 1500 4x104 4x104 2x104 E3VE series circuit breakers E3VE series circuit breakers are suitable in the circuit of AC 50/60Hz, rated operating voltage up to 660V, rated operati E3VE1 E3VE3 E3VE4 E3VE1-1B00 E3VE1-1C00 E3VE1-1D00 E3VE1-1E00 E3VE1-1F00 E3VE1-1G00 E3VE1-1H00 E3VE1-1S00 E3VE1-1J00 E3VE1-1T00 E3VE1-1K00 E3VE1-1Z00 E3VE1-1L00 E3VE1-1X00 E3VE1-1M00 E3VE1-1N00 E3VE3-1G00 E3VE3-1H00 E3VE3-1J00 E3VE3-1K00 E3VE3-1L00 E3VE3-1X00 E3VE3-1M00 E3VE3-1Y00 E3VE3-1N00 E3VE3-1P00 E3VE3-1L00 E3VE3-1M00 E3VE3-1N00 E3VE3-1P00 E3VE3-1S00 E3VE3-1R00 E3VE3-1T00 Type E3VE1 E3VE3 E3VE4-1L00 E3VE4-1M00 E3VE4-1N00 E3VE4-1P00 E3VE4-1S00 E3VE4-1R00 E3VE4-1T00 6.3-10 10-16 16-25 22-32 28-40 36-50 45-63 E3VE4 E3VE1 E3VE4 E3VE3

Greegoo Ele ctric 11.2007 http://www.greegoo.com Motor Control Device Motor protection circuit breaker Application circuit of AC 50/60Hz, rated operating voltage up to 660V, rated operating current from 0.1A to 80A, as the full- voltage starters to start and cut off motors under the AC3 load, and for the circuit protection in the circuit of 0.1A-80A. Technical parameter Dimension Thermal-magnetic motor circuit-breakers EGV2-M with built-in auxiliary contact block Standard power ratings of 3-phase motors 50/60Hz in category AC-3 Weight (kg) 0.260 0.260 0.260 0.260 0.260 0.260 0.260 0.260 0.260 0.260 0.260 0.260 0.260 0.260 0.260 ReferenceSetting range of thermal trips (A) Magnetic tripping current (A) 0.1-0.16 0.16-0.25 0.25-0.40 0.40-0.63 0.63-1 1-1.6 1.6-2.5 2.5-4 4-6.3 6-10 9-14 13-18 17-23 20-25 24-32 1.5 2.4 22.5 33.5 138 170 223 327 327 416 Thermal current Ie in (A) 0.16 0.25 0.40 0.63 1.6 2.5 6.3 220V 230V (kW) 400V 415V (kW) 440V (kW) 550V (kW) 690V (kW) 0.06 0.09 0.18 0.37 0.55 1.1 1.5 2.2 5.5 5.5 7.5 0.06 0.09 0.12 0.25 0.37 0.75 1.1 2.2 5.5 7.5 0.06 0.09 0.18 0.25 0.37 0.75 1.5 2.2 5.5 7.5 0.37 0.37 1.1 1.5 7.5 18.5 0.37 0.55 0.75 1.5 2.2 5.5 18.5 EGV2-M series circuit breakers EGV2-M series circuit breakers are mainly used for the overload and short-circuit protection for motors in the EGV2-M01 EGV2-M02 EGV2-M03 EGV2-M04 EGV2-M05 EGV2-M06 EGV2-M07 EGV2-M08 EGV2-M10 EGV2-M14 EGV2-M16 EGV2-M20 EGV2-M21 EGV2-M22 EGV2-M32 EGV2-M

Greegoo Electric 11.2007 http://www.greegoo.com Motor Control Device Motor protection circuit breaker Application circuit of AC 50/60Hz, rated operating voltage up to 660V, rated operating current from 0.1A to 80A, as the full-voltage starters to start and cut off motors under the AC3 load, and for the circuit protection in the circuit of 0.1A-80A. Technical parameter Thermal-magnetic motor circuit-breakers EGV2-ME with built-in auxiliary contact block Standard power ratings of 3-phase motors 50/60Hz in category AC-3 Weight (kg) 0.260 0.260 0.260 0.260 0.260 0.260 0.260 0.260 0.260 0.260 0.260 0.260 0.260 0.260 0.260 ReferenceSetting range of thermal trips (A) Magnetic tripping current (A) 0.1-0.16 0.16-0.25 0.25-0.40 0.40-0.63 0.63-1 1-1.6 1.6-2.5 2.5-4 4-6.3 6-10 9-14 13-18 17-23 20-25 24-32 1.5 2.4 22.5 33.5 138 170 223 327 327 416 Thermal current Ie in (A) 0.16 0.25 0.40 0.63 1.6 2.5 6.3 220V 230V (kW) 400V 415V (kW) 440V (kW) 550V (kW) 690V (kW) 0.06 0.09 0.18 0.37 0.55 1.1 1.5 2.2 5.5 5.5 7.5 0.06 0.09 0.12 0.25 0.37 0.75 1.1 2.2 5.5 7.5 0.06 0.09 0.18 0.25 0.37 0.75 1.5 2.2 5.5 7.5 0.37 0.37 1.1 1.5 7.5 18.5 0.37 0.55 0.75 1.5 2.2 5.5 18.5 Dimension EGV2-ME series circuit breakers EGV2-ME series circuit breakers are mainly used for the overload and short-circuit protection for motors in the EGV2-ME01 EGV2-ME02 EGV2-ME03 EGV2-ME04 EGV2-ME05 EGV2-ME06 EGV2-ME07 EGV2-ME08 EGV2-ME10 EGV2-ME14 EGV2-ME16 EGV2-ME20 EGV2-ME21 EGV2-ME22 EGV2-ME32 EGV2-ME

Greegoo Ele ctric 11.2007 http://www.greegoo.com Motor Control Device Motor protection circuit breaker Application /60Hz, rated operating voltage up to 660V, rated operating current from 0.1A to 80A, as the full-voltage starters to start and cut off motors under the AC3 load, and for the circuit protection in the circuit of 0.1A-80A. Technical parameter Thermal-magnetic motor circuit-breakers EGV2-RS with built-in auxiliary contact block Dimension Standard power ratings of 3-phase motors 50/60Hz in category AC-3 Weight (kg) 0.260 0.260 0.260 0.260 0.260 0.260 0.260 0.260 0.260 0.260 0.260 0.260 0.260 0.260 0.260 ReferenceSetting range of thermal trips (A) Magnetic tripping current (A) 0.1-0.16 0.16-0.25 0.25-0.40 0.40-0.63 0.63-1 1-1.6 1.6-2.5 2.5-4 4-6.3 6-10 9-14 13-18 17-23 20-25 24-32 1.5 2.4 22.5 33.5 138 170 223 327 327 416 Thermal current Ie in (A) 0.16 0.25 0.40 0.63 1.6 2.5 6.3 220V 230V (kW) 400V 415V (kW) 440V (kW) 550V (kW) 690V (kW) 0.06 0.09 0.18 0.37 0.55 1.1 1.5 2.2 5.5 5.5 7.5 0.06 0.09 0.12 0.25 0.37 0.75 1.1 2.2 5.5 7.5 0.06 0.09 0.18 0.25 0.37 0.75 1.5 2.2 5.5 7.5 0.37 0.37 1.1 1.5 7.5 18.5 0.37 0.55 0.75 1.5 2.2 5.5 18.5 EGV2-RS series circuit breakers EGV2-RS series circuit breakers are mainly used for the overload and short-circuit protection for motors in the circuit of AC 50 EGV2-RS01 EGV2-RS02 EGV2-RS03 EGV2-RS04 EGV2-RS05 EGV2-RS06 EGV2-RS07 EGV2-RS08 EGV2-RS10 EGV2-RS14 EGV2-RS16 EGV2-RS20 EGV2-RS21 EGV2-RS22 EGV2-RS32 EGV2-RS

Greegoo Electric 11.2007 http://www.greegoo.com Motor Control Device Motor protection circuit breaker Technical parameter Standard power ratings of 3-phase motors 50/60Hz in category AC-3 (kW) 0.37 0.75 1.1/1.5 2.2 5.5/7.5 18.5 ReferenceSetting range of thermal trips (A) Magnetic tripping current (A) 1-1.6 1.6-2.5 2.5-4 4-6 6-10 10-16 16-25 25-40 40-63 56-80 120 190 300 480 720 960 Thermal current Ie in (A) 1.6 2.5 Technical parameter Standard power ratings of 3-phase motors 50/60Hz in category AC-3 (kW) 0.37 0.75 1.1/1.5 2.2 5.5/7.5 18.5 Reference GV3-ME80 Setting range of thermal trips (A) Magnetic tripping current (A) 1-1.6 1.6-2.5 2.5-4 4-6 6-10 10-16 16-25 25-40 40-63 56-80 120 190 300 480 720 960 Thermal current Ie in (A) 1.6 2.5 Dimension EGV3-M series circuit breakers EGV3-M06 EGV3-M07 EGV3-M08 EGV3-M10 EGV3-M14 EGV3-M20 EGV3-M25 EGV3-M40 EGV3-M63 EGV3-M80 EGV3-ME series circuit breakers EGV3-ME06 EGV3-ME07 EGV3-ME08 EGV3-ME10 EGV3-ME14 EGV3-ME20 EGV3-ME25 EGV3-ME40 EGV3-ME63 E EGV3-M EGV3-ME

Greegoo Ele ctric 11.2007 http://www.greegoo.com Motor Control Device Motor protection circuit breaker Technical parameter Thermal-magnetic motor circuit-breakers EGV4-M with built-in auxiliary contact block Standard power ratings of 3-phase motors 50/60Hz in category AC-3 Weight (kg) 0.260 0.260 0.260 0.260 0.260 0.260 0.260 0.260 0.260 0.260 0.260 0.260 0.260 0.260 0.260 ReferenceSetting range of thermal trips (A) Magnetic tripping current (A) 0.1-0.16 0.16-0.25 0.25-0.40 0.40-0.63 0.63-1 1-1.6 1.6-2.5 2.5-4 4-6.3 6-10 9-14 13-18 17-23 20-25 24-32 1.5 2.4 22.5 33.5 138 170 223 327 327 416 Thermal current Ie in (A) 0.16 0.25 0.40 0.63 1.6 2.5 6.3 220V 230V (kW) 400V 415V (kW) 440V (kW) 550V (kW) 690V (kW) 0.06 0.09 0.18 0.37 0.55 1.1 1.5 2.2 5.5 5.5 7.5 0.06 0.09 0.12 0.25 0.37 0.75 1.1 2.2 5.5 7.5 0.06 0.09 0.18 0.25 0.37 0.75 1.5 2.2 5.5 7.5 0.37 0.37 1.1 1.5 7.5 18.5 0.37 0.55 0.75 1.5 2.2 5.5 18.5 Technical parameter Thermal-magnetic motor circuit-breakers EGV4-ME with built-in auxiliary contact block Standard power ratings of 3-phase motors 50/60Hz in category AC-3 Weight (kg) 0.260 0.260 0.260 0.260 0.260 0.260 0.260 0.260 0.260 0.260 0.260 0.260 0.260 0.260 0.260 ReferenceSetting range of thermal trips (A) Magnetic tripping current (A) 0.1-0.16 0.16-0.25 0.25-0.40 0.40-0.63 0.63-1 1-1.6 1.6-2.5 2.5-4 4-6.3 6-10 9-14 13-18 17-23 20-25 24-32 1.5 2.4 22.5 33.5 138 170 223 327 327 416 Thermal current Ie in (A) 0.16 0.25 0.40 0.63 1.6 2.5 6.3 220V 230V (kW) 400V 415V (kW) 440V (kW) 550V (kW) 690V (kW) 0.06 0.09 0.18 0.37 0.55 1.1 1.5 2.2 5.5 5.5 7.5 0.06 0.09 0.12 0.25 0.37 0.75 1.1 2.2 5.5 7.5 0.06 0.09 0.18 0.25 0.37 0.75 1.5 2.2 5.5 7.5 0.37 0.37 1.1 1.5 7.5 18.5 0.37 0.55 0.75 1.5 2.2 5.5 18.5 EGV4-M series circuit breakers box EGV4-M01 EGV4-M02 EGV4-M03 EGV4-M04 EGV4-M05 EGV4-M06 EGV4-M07 EGV4-M08 EGV4-M10 EGV4-M14 EGV4-M16 EGV4-M20 EGV4-M21 EGV4-M22 EGV4-M32 EGV4-ME series circuit breakers box EGV4-ME01 EGV4-ME02 EGV4-ME03 EGV4-ME04 EGV4-ME05 EGV4-ME06 EGV4-ME07 EGV4-ME08 EGV4-ME10 EGV4-ME14 EGV4-ME16 EGV4-ME20 EGV4-ME21 EGV4-ME22 EGV4-ME32 EGV4-M EGV4-ME

Greegoo Electric 11.2007 http://www.greegoo.com Motor Control Device Motor protection circuit breaker Technical parameter Application 750V, rated operating voltage up to 660V, rated operating current from 0.1A to 25A. It is used for protecting the motor against overload, short-circuit and phase-failure, It can be also used for starting and breaking the starter of motor and for the circuit protection in the circuit of 25A. Switching capacity 150/50KA/415V Short-circuit release, fixed setting to 14X Iu Single-phasing sensitive With screws or spring loaded terminals Comply with IEC/EN60947 Standard power ratings of 3-phase motors 50/60Hz in category AC-3 (kW) 0.06 0.09 0.12 0.25 0.55 0.75 1.5 2.2 5.5 7.5 12.5 Setting range of thermal trips (A) Norminal breaking capacity (A) 0.1-0.16 0.16-0.25 0.25-0.4 0.4-0.63 0.63-1 1-1.6 1.6-2.5 2.5-4 4-6.3 6.3-10 6.3-10 10-16 10-16 16-20 20-25 100 100 100 100 100 100 100 100 100 100 100 Thermal current Ie in (A) 0.16 0.25 0.4 0.63 1.6 2.5 6.3 6.6 Reference DZM0-32 EDZMO motor protective circuit breaker EDZMO Motor Protective Circuit Breaker is applicable for the circuit of Ac 50/60Hz, rated insulation voltage EDZM0-01 EDZM0-02 EDZM0-03 EDZM0-04 EDZM0-05 EDZM0-06 EDZM0-07 EDZM0-08 EDZM0-10 EDZM0-14 EDZM0-16 EDZM0-20 EDZM0-21 EDZM0-22 E EDZM0

Greegoo Ele ctric 11.2007 http://www.greegoo.com Motor Control Device Motor protection circuit breaker Application e circuit of AC 50/60Hz, rated operating voltage up to 660V, rated operating current from 0.11A to 25A. They can be also used for circuit protection in the circuit of 0.11A-25A. Standard power ratings of 3-phase motors 50/60Hz in category AC-3 (kW) 0.04 0.06 0.06 0.09 0.09 0.12 0.18 0.18 0.25 0.37 0.55 0.75 0.75 1.1 1.5 1.5 2.2 5.5 0.04 0.06 0.06 0.09 0.09 0.12 0.18 0.18 0.25 0.37 0.55 0.75 0.75 1.1 1.5 1.5 2.2 Short circuit breaking capacity under the condition of AC 400V 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 Setting range of thermal trips (A) Magnetic tripping current (A) 0.11-0.16 0.14-0.2 0.18-0.25 0.22-0.32 0.28-0.4 0.35-0.5 0.45-0.63 0.55-0.8 0.7-1 0.9-1.25 1.1-1.6 1.4-2 1.8-2.5 2.2-3.2 2.8-4 3.5-5 4.5-6.3 5.5-8 7-10 9-12 0.11-0.16 0.14-0.2 0.18-0.25 0.22-0.32 0.28-0.4 0.35-0.5 0.45-0.63 0.55-0.8 0.7-1 0.9-1.25 1.1-1.6 1.4-2 1.8-2.5 2.2-3.2 2.8-4 3.5-5 4.5-6.3 5.5-8 2.1 2.6 3.3 4.2 5.2 6.5 8.2 104 130 156 2.1 2.6 3.3 4.2 5.2 6.5 8.2 104 Thermal current Ie in (A) 0.16 0.2 0.25 0.32 0.4 0.5 0.63 0.8 1.25 1.6 2.5 3.2 6.3 0.16 0.2 0.25 0.32 0.4 0.5 0.63 0.8 1.25 1.6 2.5 3.2 6.3 Reference E3RV series circuit breakers E3RV series circuit breakers are mainly used for the overload, short-circuit and phase-failure protection for motors in th E3RV10 11-0AA1. E3RV10 11-0BA1. E3RV10 11-0CA1. E3RV10 11-0DA1. E3RV10 11-0EA1. E3RV10 11-0FA1. E3RV10 11-0GA1. E3RV10 11-0HA1. E3RV10 11-0JA1. E3RV10 11-0KA1. E3RV10 11-1AA1. E3RV10 11-1BA1. E3RV10 11-1CA1. E3RV10 11-1DA1. E3RV10 11-1EA1. E3RV10 11-1FA1. E3RV10 11-1GA1. E3RV10 11-1HA1. E3RV10 11-1JA1. E3RV10 11-1KA1. E3RV10 21-0AA1. E3RV10 21-0BA1. E3RV10 21-0CA1. E3RV10 21-0DA1. E3RV10 21-0EA1. E3RV10 21-0FA1. E3RV10 21-0GA1. E3RV10 21-0HA1. E3RV10 21-0JA1. E3RV10 21-0KA1. E3RV10 21-1AA1. E3RV10 21-1BA1. E3RV10 21-1CA1. E3RV10 21-1DA1. E3RV10 21-1EA1. E3RV10 21-1FA1. E3RV10 21-1GA1. E3RV10 21-1HA1. E3RV10-11 E3RV10-21

Greegoo Electric 11.2007 http://www.greegoo.com Motor Control Device Motor protection circuit breaker Standard power ratings of 3-phase motors 50/60Hz in category AC-3 (kW) 5.5 7.5 7.5 Short circuit beraking capacity under the condition of AC 400V 100 100 Setting range of thermal trips (A) Magnetic tripping current (A) 7-10 9-12.5 11-16 14-20 17-22 20-25 130 163 208 260 286 325 Thermal current Ie in (A) 12.5 The recommended data for four-phase standard electromotor under the condition of AC50Hz, 400V. What affects the product most is the factual starting data and rated data of the protected electomotor. Dimension 1. 2-pole side supplementary switch; 2. Signal switch or 4-pole side supplementary switch; 3. Supplementary releaser; 4. Transverse supplementary contact; 5. Patching slice for screw installation; 6. Punching template; 7. 35mm standard installation guide way; 8. Lock the location of breaking the diameter of the staple is 3.5mm or 4.5mm. E3RV10-11 E3RV10-21 Reference E3RV10 21-1JA1 E3RV10 21-1KA1 E3RV10 21-4AA1 E3RV10 21-4BA1 E3RV10 21-4CA1 E3RV10 21-4DA1