All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, TruAccuracyTM and Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: 17-4 PH®, AMP®, Deutsch®, Hirschmann®, Metri-Pack®, Superseal® and VCR®. For more information, see Ashcroft Brands & Trademarks of 8 E2G Pressure Transducer ELECTRICAL SPECIFICATIONS Circuit Protection: Reverse polarity protected Output Signal: 0-5 Vdc (3 Wire) 1-5 Vdc (3 Wire) 1-6 Vdc (3 Wire) 0-10 Vdc (3 Wire) 1-11 Vdc (3 Wire) 0.1-5 Vdc (3 Wire) 0.1-10 Vdc (3 Wire) 0.5-4.5 Vdc (3 Wire) 4-20 mA (2 Wire) 20-4 mA (2 Wire) Supply Voltage: (unregulated) Min. Max:

9 Vdc 36 Vdc

14 Vdc 36 Vdc

Adjustability: ±5% of span non-interactive offset and span Supply Current: <8 mA (Vout) Curent Source/Sink for Voltage Output 1 mA (source)/ 0.1 mA (sink) MAX. Withstand/Breakdown 100 Vdc/Vac, optional 500 Vdc/Vac

FEATURES

„ Ranges vac through 20,000 psi „ IP66/67 Ingress rating „ Wide selection of electrical and process connections „ Customizable configurations „ External magnetic offset and span adjustment „ Barometric pressure ranges available (standard and custom ranges) „ SIL 3 capable TYPICAL USES „ Off-Road equipment „ Construction machinery „ HVAC/Refrigeration „ Compressor control „ Pump monitoring „ Agricultural equipment „ Diagnostic kits „ Engine monitoring „ Process automation and controls „ Hydraulic and pneumatic sensing KEY BENEFITS

  • Highly configurable
  • Easy calibration of offset and span
  • SIL Certified PERFORMANCE SPECIFICATIONS Reference Temperature: 70 °F ±3.6 °F (21 °C ±2 °C) Static Accuracy: ±0.25% of span, ±0.50% of span, ±1.0% of span, (0-1.5# Range only available in ±0.5% and 1.0% accuracy) Terminal Point Method includes: hysteresis, linearity, repeatability, offset and span Stability: ±0.25% year at reference conditions ENVIRONMENTAL SPECIFICATIONS Thermal Coefficients: Offset: ±0.005% /°F from -40 °F to 257 °F (±0.009% /°C from -40 °C to 125 °C) Span: ±0.005% /°F from -40 °F to 257 °F (±0.009% /°C from -40 °C to 125 °C) Temperature Limits: Storage: Operating: Media: -58 °F to 257 °F (-50 °C to 125 °C) -40 °F to 257 °F (-40 °C to 125 °C) -40 °F to 257 °F (-40 °C to 125 °C) Humidity: 0-100% (non-condensing) FUNCTIONAL SPECIFICATIONS Response Time (Output) 4 ms Gauge/Compound Pressure Ranges: VAC to 20,000 psig Shock: 80 g, 6 ms, Haversine Vibration: Random: 10 g RMS 20-2000 Hz Absolute Pressure Ranges: 0 to 500 psia Proof Pressure: 1.2X - 2X (See Table 1 on page 2) Burst Pressure: 3X - 8X (See Table 1 on page 2)

All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, TruAccuracyTM and Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: 17-4 PH®, AMP®, Deutsch®, Hirschmann®, Metri-Pack®, Superseal® and VCR®. For more information, see Ashcroft Brands & Trademarks of 8 EMC: Directive 2014/30/EU, and EN61326-1, EN61326-2-3 (Industrial Env.) Immunity: 61000-4-2 (ESD) ±4 kV/±8 kV (Contact/Air) 61000-4-3 (Radiated RF) 10 V/m to 1 GHZ, 3 V/m to 2 GHz, 1 V/m to 2.7 GHz 61000-4-4 (EFT/Burst) ±1 kV (5/50 ns, 5 kHz) 61000-4-5 (Surge) ±1 kV, Earth to Shield over all I/O lines 61000-4-6 (Conducted RF) 3 V/ (0.15 to 80 MHz) 61000-4-8 (Line Freq. Magnetic) 30 A/m Emissions: EN 55011 (CISPR 11) Class A, Group 1 & FCC (47 CFR 15) PHYSICAL SPECIFICATIONS Ingress Rating: IP66 (NEMA 4X) (STD.) IP67 (IP69K Consult Factory) WETTED MATERIAL Diaphragm: Sensor: A B C D Material: 17-4 PH®* Stainless steel* 316L Stainless steel 316L Stainless steel, liquid isolated A286 *"A" sensor with ranges of 10,000 psi and above include 316 Stainless steel and 17-4 PH® H900 Stainless steel (process connection). Process Connection: 316L Stainless steel NON-WETTED MATERIAL Housing: 316L Stainless steel EMC TESTING TABLE 1: PROOF & BURST PRESSURE MULTIPLIERS A Sensor - 17-4 PH® SS B Sensor -

316 LSS

Range Proof Burst Proof Burst Proof Burst Proof Burst ( psi) 1.5 3.3X 5X 5 3X 5X 10 2X 5X 15 2X 5X 30 2X 8X 1.5X 8X 2X 5X 45 1.9X 8X 1.4X 8X 3.1X 5X 50 2.9X 8X 2.2X 8X 2.8X 5X 60 2.4X 8X 1.8X 8X 2.3X 5X 75 1.9X 8X 1.5X 8X 1.9X 5X 100 2X 8X 1.5X 8X 3X 5X 150 2X 8X 1.5X 8X 2X 4X 200 2X 8X 1.5X 8X 3X 3X 300 1.9X 8X 1.5X 8X 2X 3X 500 2X 8X 1.2X 5X 3X 4X 750 1.9X 8X 1.2X 5X 1000 2X 8X 1.2X 5X 1500 1.9X 8X 1.2X 5X 2000 2X 8X 1.2X 5X 3000 1.9X 5X 1.2X 5X 5000 1.5X 5X 1.2X 5X 2.4X 5X 7500 1.5X 3X 1.6X 5X 10,000 1.2X 3X 1.2X 5X 15,000 1.7X 3X 1.7X 5X 20,000 1.3X 3X 1.3X 5X (Compound) VAC# 2X 5X V&15# 2X 5X V&30# 2X 5X V&45# 2X 8X 1.5X 8X V&60# 2X 8X 1.5X 8X 2X 5X V&100# 2X 8X 1.5X 8X V&150# 2X 8X 1.5X 8X 2X 4X V&200# 2X 8X 1.5X 8X V&300# 2X 8X 1.5X 8X 2X 3X (psia) 15 2X 5X 30 2X 5X 50 2X 5X 150 2X 4X 300 2X 3X 500 2X 3X APPROVALS CE/UKCA, UL/cUL Recognized component (UL 61010-1, CSA 22.2 61010-1), Electrical Equipment for Measurement, Control, and Laboratory Use. Ashcroft’s TruAccuracy™ specification is exclusively based on terminal point methodology instead of statistically derived schemes like ‘best fit straight line’. TruAccuracy™ means the Ashcroft E2G has ±0.25% of span accuracy out of the box. Zero and span setting errors are already included in the ±0.25% of span accuracy spec. The E2G is ready to be installed with no additional calibration adjustments required. A unit from another manufacturer advertised as ±0.25% best fit straight line may actually be a ±1.25% to ±2.25% device. Using best fit straight line method, the accuracy spec does not include zero and span setting errors, which can be as much as ±1.00% each. What Does It Mean?

All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, TruAccuracyTM and Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: 17-4 PH®, AMP®, Deutsch®, Hirschmann®, Metri-Pack®, Superseal® and VCR®. For more information, see Ashcroft Brands & Trademarks of 8 ORDERING CODE Example: E2G B 3 C F02 42 CC X 10 F 100# -XNH Model E2G - General Purpose E2G Sensor Materials - See Table 2 on page 4 for more options A - 17-4 PH® Stainless steel B - 316L Stainless steel B C - 316L Stainless steel (liquid isolated) D - A286 Accuracy 3 - 0.25% span (not available with 1.5 psi range) 3 5 - 0.50% span 7 - 1.00% span Calibration Chart N - Without calibration chart C - With calibration chart C Pressure Connections - See Table 3 on page 5 for more options F02 - (¼ NPT Female) F02 Output Type 05 - 0-5 Vdc (not available with X1L variation) 10 - 0-10 Vdc (not available with X1L variation) 11 - 1-11 Vdc 12 - 1-10 Vdc 15 - 1-5 Vdc 16 - 1-6 Vdc 42 - 4-20 mA 42 45 - 0.5-4.5 Vdc non-ratiometric 00 - Custom Electrical Connections - See Table 4 on page 6 for more options CC - (½ NPT conduit w/cable) CC Mating Connector M - With mating connector X - Without mating connector X Cable Length Max cable length of 30ft for outputs 05, 10, 11, 12, 13, 15, 16 and 45; Max cable length of 99ft for outputs 24 and 42 00 - No cable XX - 01 to 99 10 Unit of Length F - Feet F M - Meter N - Inches 0 - No cable Pressure Ranges - Coding example only, see Table 5 on page 7 for more options 100# - 100 psig 100# Options (if choosing an option(s) must include an “X”) -X__ NN - Paper tag NH - Stainless steel tag NH 6B - Cleaned for oxygen service 6W - Cleaned per ASME B40.100 Level IV, NOT marked for oxygen service 1L - SIL Certification for E2 series transdcuers Accessory Part Number Offset and Span Adjustment Magnet 266A143-01 Accessories must be ordered separately

All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, TruAccuracyTM and Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: 17-4 PH®, AMP®, Deutsch®, Hirschmann®, Metri-Pack®, Superseal® and VCR®. For more information, see Ashcroft Brands & Trademarks of 8 TABLE 2 - SENSOR PRESSURE RANGE psi Sensor Material bar Sensor Material inHg Sensor Material A 17-PH® SS B 316L SS C

316 ISO

D A286 A 17-PH® SS B 316L SS C D A286 A 17-PH® SS B 316L SS C D A286 1.5# • 5# • 400MB • 10IM • 10# • 600MB • 20IM • 15# • 1BR • 30IM • 5000# • • • 1000BR • 1000IMA • 15#A • 16BRA • 30#A • 20BRA • 50#A • 100#A • 120#A • 300#A •

All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, TruAccuracyTM and Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: 17-4 PH®, AMP®, Deutsch®, Hirschmann®, Metri-Pack®, Superseal® and VCR®. For more information, see Ashcroft Brands & Trademarks of 8 TABLE 3 - PRESSURE CONNECTION DIMENSIONS 1⁄8 NPT Male Code "M01" .72 .875 Hex. ¼ NPT Male Code "M02" .98 .875 Hex. ½ NPT Male Code "M04" 1.16 .875 Hex. 7⁄16-20 UNJF-3A Code "M76" .91 .875 Hex. O-ring 7/16 -20 UNF-2A O-ring Boss Code "MEK" .71 .875 Hex. G¼B Male Code "MG2" .87 .875 Hex. 1⁄8 NPT Female Code "F01" .47 .875 Hex. Ø.81 G½B Male Code "MG4" 1.19 1.063 Hex. gasket G¼A DIN 3852-E Code "MGA" .83 .47 .875 Hex. .80 Ø .81 7⁄16-20 UNF -2B O-Ring Boss Code "FRW" .875 Hex. ¼ VCR gland with 9⁄16-18 Female nut Code "FV2" 1.98 MAX. 1.48 .75 Hex .875 Hex. ¼ NPT Female Code "F02" .66 .875 Hex. Ø.81 ½ NPT Female Code "F04" .91 1.063 Hex. Ø 1.06 .71 Ø .875 9⁄16-18 UNF -2B Female Code "F09" 1.063 Hex. 1.48 ¼-VCR Gland with 9⁄16-18 Male Nut Code "MV2" .875 Hex. .63 Hex. 1⁄8 NPT Male Code: MO1 MAWP: 20,000 psi G½ B Male (EN837-1) Code: MG4 MAWP: 20,000 psi ¼ NPT Male Code: MO2 MAWP: 20,000 psi G¼ A-MALE (stud end DIN 3852-E G¼) Code: MGA MAWP: 10,000 psi ½ NPT Male Code: MO4 MAWP: 10,000 psi ¼-18 NPT Female Code: F02 MAWP: 10,000 psi 7⁄16-20 UNJF-3A 37 ° Flare (SAE AS4395) Code: M76 MAWP: 20,000 psi ½-14 NPT Female Code: F04 MAWP: 5,000 psi 7⁄16-20 UNJF-2A SAE- Male (SAE J1926 O-Ring Boss seal) Code: MEK MAWP: 10,000 psi 9⁄16-18 UNF-2B Female Code: F09 MAWP: 25,000 psi G¼ B-Male (EN837-1) Code: MG2 MAWP: 20,000 psi 1⁄8 -27 NPT Female Code: F01 MAWP: 10,000 psi 7⁄16-20 UNF-2B SAE J1926 Code: FRW MAWP: 9,100 psi ¼ Compatible with VCR® gland with 9⁄16-18 Female Swivel Nut Code: FV2 MAWP: 5,100 psi ¼ Compatible with VCR® gland with 9⁄16-18 Male Swivel Nut Code: MV2 MAWP: 5,100 psi

All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, TruAccuracyTM and Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: 17-4 PH®, AMP®, Deutsch®, Hirschmann®, Metri-Pack®, Superseal® and VCR®. For more information, see Ashcroft Brands & Trademarks of 8 .81 Ø.47 2.33 .75 L .78 MIL-DTL-26482 8-4 Code "B4" "B4" with Mate B A D C "HM" with Mate .66 .63 .63 1.31 .63 .98 L Mini Hirschmann Code "HM" 1.30 1.142 Hex. M20 Conduit w/ Flying Leads Code "MF" L 1.30 L .875 Hex. ½ NPT Conduit w/ Flying Leads Code "CF" 1.16 Ø 1.34 2.11 1.08 L 1.37 EN 175301-803 Form A Code "DA" "DA" with Mate 1 2 GND 1.10 L .875 Hex. ½ NPT Conduit w/ Cable Code "CC/CV" 1.36 1.01 1.75 .62 L DT04-3P Code "DT" "DT" with Mate A C B 1.31 1.02 1.77 L 1.02 .92 AMP Superseal 3-pin Code "AP" "AP" with Mate 3 2 1 1.36 "GN" with Mate 1.04 .08 B A C Ø .63 .90 Metri-pack 3-pin Code "GN" L .81 1.45 .62 1.15 L EN 175301-803 Form C Code "DC" "DC" with Mate 1 2 GND .65 Ø.75 Overmold Cable Code "FC/FV" L "EW" with Mate 1.47 Ø.71 .47 Ø.47 1.24 M12 4-pin Code "EW" L 1.10 L 1.142 Hex. M20 Conduit w/Cable Code "MC/MV" Metri-Pack ® 3-Pin Code: GN – IP67 (NEMA 4X) -40 °F to 185 °F (-40 °C to 85 °C) AMP® Superseal ® 3-Pin Code: AP – IP66 (NEMA 4X) -40 °F to 185 °F (-40 °C to 85 °C) Over-Mold Cable Code: FC, FV* – IP67 (NEMA 4X) -40 °F to 185 °F (-40 °C to 85 °C) M12 4-Pin Code: EW, RW** – IP66 (NEMA 4X) -40 °F to 185 °F (-40 °C to 85 °C) TABLE 4 - ELECTRICAL CONNECTION DIMENSIONS Maximum temperature range listed DEUTSCH ® DT04 3-Pin Code: DT – IP66 (NEMA 4X) -40 °F to 185 °F (-40 °C to 85 °C) Hirschmann ® EN 175301-803 Form A Code: DA – IP65 (NEMA 4X) -40 °F to 185 °F (-40 °C to 85 °C) Mini-Hirschmann ® Code: HM – IP65 (NEMA 4X) -40 °F to 185 °F (-40 °C to 85 °C) MIL DTL 26482 8 4-Pin Code: B4 – No IP or NEMA rating -40 °F to 221 °F (-25 °C to 105 °C) Hirschmann ® EN 175301-803 Form C Code: DC IP65 (NEMA 4X) -40 °F to 185 °F (-40 °C to 85 °C) M20 Conduit With Cable Code: MC, MV* IP67 (NEMA 4X) -40 °F to 257 °F (-40 °C to 125 °C) ½ NPT Conduit With Cable Code: CC, CV* IP67 (NEMA 4X) -40 °F to 257 °F (-40 °C to 125 °C) ½ NPT Conduit With Flying Leads Code: CF IP67 (NEMA 4X) -40 °F to 257 °F (-40 °C to 125 °C) M20 Conduit With Flying Leads Code: MF IP67 (NEMA 4X) -40 °F to 257 °F (-40 °C to 125 °C) Notes: * Indicates Vented Cable ** See EW and RW pin-outs on page 8

All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, TruAccuracyTM and Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: 17-4 PH®, AMP®, Deutsch®, Hirschmann®, Metri-Pack®, Superseal® and VCR®. For more information, see Ashcroft Brands & Trademarks of 8 TABLE 5 - PRESSURE RANGES Vac. PSI bar inHg VAC# VACBR VACIM Compound V&15# V&1BR V&30IM — V&1.6BR — V&30# V&2BR V&60IM V&45# — V&100IM V&60# V&4BR — — V&6BR — V&100# — V&200IM V&150# — — V&200# — — V&300# — — 1.5# 105MB 3IM 5# 400MB 10IM Positive Pressure (psig) — 600MB — 10# — 20IM 15# 1BR 30IM — 1.6BR 50IM 30# 2BR — — 2.5BR — 45# — — 50# — 100IM 60# 4BR 75# — — — 6BR — 100# — 200IM 150# 10BR 300IM 200# — — — 16BR — 250# — 500IM 300# 20BR — — 25BR — 500# — 1000IM — 40BR — 750# — — — 60BR — 1000# — — 1500# 100BR — 2000# 160BR — — 200BR — 2500# — — 3000# — — — 250BR — 5000# — — — 400BR — 7500# — — — 600BR — 10,000# — — 15,000# 1000BR — 20,000# — — Absolute Pressure (psia) 15#A 1BRA 30IMA — 1.6BRA 50IMA 30#A 2BRA — — 2.5BRA — 50#A — 100IMA — 4BRA — — 6BRA — 100#A — 200IMA — 10BRA 300IMA 200#A — — — 16BRA 500IMA — 20BRA — 500#A — — 3.00 .98 Ø.866 .47 ¼ NPT Male Code "M02"

4.45 Cable Length

0.875 4.34 Ø 0.87 0.875 DIMENSIONS For reference only, consult Ashcroft for specific dimensional drawings

All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, TruAccuracyTM and Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: 17-4 PH®, AMP®, Deutsch®, Hirschmann®, Metri-Pack®, Superseal® and VCR®. For more information, see Ashcroft Brands & Trademarks of 8 V+CASE GROUND V- V- EW CURRENT OUTPUT V+CASE GROUND COMMON OUTPUT EW VOLTAGE OUTPUT V+CASE GROUND V- V- EW CURRENT OUTPUT V+CASE GROUND COMMON OUTPUT EW VOLTAGE OUTPUT EW AND RW PIN-OUT DRAWINGS V+V- CASE GROUND V- RW CURRENT OUTPUT V+OUTPUT CASE GROUND COMMON RW VOLTAGE OUTPUT V+V- CASE GROUND V- RW CURRENT OUTPUT V+OUTPUT CASE GROUND COMMON RW VOLTAGE OUTPUT