R Long Barrel Inductive Prox E2E2 3-Wire DC Rugged Inductive Prox Sensors Meet IP67 Requirements H Solid potted internal circuitry withstands shocks and water washdown to IP67 H Thick nickel-plated brass barrel has wrench flats for easy installation H High visibility indicator H Connector and prewired versions
Ordering Information
Type Size Sensing distance Output Part numberyp g p NO NC Shielded M12 2 mm NPN E2E2-X2C1 E2E2-X2C2 2m m PNP E2E2-X2B1 E2E2-X2B2 M18 5 mm NPN E2E2-X5C1 E2E2-X5C25m m PNP E2E2-X5B1 E2E2-X5B2 M30 10 mm NPN E2E2-X10C1 E2E2-X10C210 mm PNP E2E2-X10B1 E2E2-X10B2 Unshielded M12 5 mm NPN E2E2-X5MC1 E2E2-X5MC2Unshielded 5m m PNP E2E2-X5MB1 E2E2-X5MB2 M18 10 mm NPN E2E2-X10MC1 E2E2-X10MC2 10 mm PNP E2E2-X10MB1 E2E2-X10MB2 M30 NPN E2E2-X18MC1 E2E2-X18MC2 18 mm PNP E2E2-X18MB1 E2E2-X18MB2 J SENSORS WITH M12 CONNECTORS Type Size Sensing distance Output Part numberyp g p NO NC Shielded M12 2 mm NPN E2E2-X2C1-M1 E2E2-X2C2-M1 2m m PNP E2E2-X2B1-M1 E2E2-X2B2-M1 M18 NPN E2E2-X5C1-M1 E2E2-X5C2-M1 5m m PNP E2E2-X5B1-M1 E2E2-X5B2-M1 M30 10 mm NPN E2E2-X10C1-M1 E2E2-X10C2-M1 10 mm PNP E2E2-X10B1-M1 E2E2-X10B2-M1 Unshielded M12 NPN E2E2-X5MC1-M1 E2E2-X5MC2-M1Unshielded 5m m PNP E2E2-X5MB1-M1 E2E2-X5MB2-M1 M18 10 mm NPN E2E2-X10MC1-M1 E2E2-X10MC2-M1 10 mm PNP E2E2-X10MB1-M1 E2E2-X10MB2-M1 M30 NPN E2E2-X18MC1-M1 E2E2-X18MC2-M1 18 mm PNP E2E2-X18MB1-M1 E2E2-X18MB2-M1
E2E2 3-Wire DC E2E2 3-Wire DC J ACCESSORIES Description Part number Mounting brackets Fits M12 size sensors Fits M18 size sensors Fits M30 size sensors Y92E-B12 Y92E-B18 Y92E-B30 Silicone rubber covers for shielded sensorsFits M12 size sensors Fits M18 size sensors Fits M30 size sensors Y92E-E12-2 Y92E-E18-2 Y92E-E30-2 Connector cordsets See Y96E Connector Cordsets data sheet for details J REPLACEMENT PARTS Description Part number Mounting hardware including one pair of metal nuts and one washer Fits M12 size sensors Fits M18 size sensors Fits M30 size sensors M12-MHWS M18-MHWS M30-MHWS Specifications Part number E2E2-X2Cj/Bj E2E2-X5MCj/Bj E2E2-X5Cj/Bj E2E2-X10MCj/Bj E2E2-X10Cj/Bj E2E2-X18MCj/Bj Size M12 M18 M30 Type Shielded Unshielded Shielded Unshielded Shielded Unshielded Sensing distance 2 mm (0.08 in) ±10% 5 mm (0.20 in) ±10% 5 mm (0.20 in) ±10% 10 mm (0.39 in) ±10% 10 mm (0.39 in) ±10% 18 mm (0.71 in) ±10% Supply voltage (operating voltage range) 12 to 24 VDC, ripple (p-p): 10% max., (10 to 55 VDC) Current consumption 13 mA max. Sensing object Magnetic metals (refer toEngineering Datafor non-magnetic metals) Setting distance 0t o1 . 6m m (0 to 0.06 in) 0t o4 . 0m m (0 to 0.16 in) 0t o4 . 0m m (0 to 0.16 in) 0t o8 . 0m m (0 to 0.31 in) 0t o8 . 0m m (0 to 0.31 in) 0t o1 4 . 0m m (0 to 0.55 in) Standard object (mild steel) 12 x 12 x 1 mm (0.47 x 0.47 x 0.04 in) 1 5x1 5x1m m (0.59 x 0.59 x 0.04 in) 18 x 18 x 1 mm (0.71 x 0.71 x 0.04 in) 3 0x3 0x1m m (1.18 x 1.18 x 0.04 in) 3 0x3 0x1m m (1.18 x 1.18 x 0.04 in) 5 4x5 4x1m m (2.13 x 2.13 x 0.04 in) Differential travel 10% max. of sensing distance Operation (with sensing object approaching) B1/C1 models: Load ON B2/C2 models: Load OFF Control output (switching capacity) 200 mA max., open collector Circuit protection Reverse connection protection, surge absorber, load short-circuit protection Indicator Operation indicator (red LED) Ambient temperature Operating -- 4 0°Ct o8 5°C( - - 4 0°F to 185°F) with no icing Ambient humidity Operating 35% to 95% Temperature influence ±15% max. of sensing distance at 23°C in temperature range of - -40°Ct o8 5°C( - - 4 0°F to 185°F) ±10% max. of sensing distance at 23°C in temperature range of - -25°Ct o7 0°C( - - 1 3°F to 158°F) Voltage influence ±1% max. of sensing distance in rated voltage range±15% Residual voltage 2.0 V max. (under load current of 200 mA with cable length of 2 m) Insulation resistance 50 MΩ min. (at 500 VDC) between current carry parts and case Dielectric strength 1,000 VAC for 1 min between current carry parts and case Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude for 10 times each in X, Y, and Z axes Shock resistance 1,000 m/s2 (approx. 100G) for 10 times each in X, Y, and Z axes (This table continues on the next page.)
E2E2 3-Wire DCE2E2 3-Wire DC Specifications Table - - continued from previous page Part number E2E2-X2Cj/Bj E2E2-X5MCj/Bj E2E2-X5Cj/Bj E2E2-X10MCj/Bj E2E2-X10Cj/Bj E2E2-X18MCj/Bj Enclosure IEC IP67 rating NEMA 1, 4, 6, 12, 13 Weight 75 g 160 g 220 g Material Body Brass Sensing face PBT Operation J OUTPUT CIRCUITS E2E2-XjCj DC 3-wire Models Main circuit Brown 1 Black 4 (or 2) Blue 3 Load 100 Ω E2E2-XjBj DC 3-wire Models Main circuit Brown 1 Black 4 (or 2) Blue 3 Load 100 Ω J TIMING CHART E2E2-XjCj/Bj DC 3-wire Models NPN/PNP Open Collector Output Sensing object Control output Red indicator Yes No Lit Not lit ON OFF Engineering Data J OPERATING RANGE (TYPICAL) Shielded Models E2E2-XjCj/Bj Sensing distance X (mm) E2Ej-X2j Sensing distance X (mm) E2Ej-X10j E2Ej-X5j Y (mm) Y (mm)
E2E2 3-Wire DC E2E2 3-Wire DC E2E2-XjMCj/Bj Sensing distance X (mm) E2Ej-X5Mj Sensing distance X (mm) E2Ej-X18Mj E2Ej-X10Mj Y (mm) Y (mm) Unshielded Models J SENSING DISTANCE VS. SENSING OBJECT (TYPICAL) E2E2-X2Cj/Bj E2E2-X5Cj/Bj E2E2-X10Cj/Bj Sensing distance (mm) Side length of sensing object d (mm) Sensing distance (mm) Sensing distance (mm) Side length of sensing object d (mm) Side length of sensing object d (mm) Mild steel Stainless steel (SUS304) Brass Aluminum Mild steel Stainless steel (SUS304) Brass Aluminum Mild steel Stainless steel (SUS304) Brass Aluminum E2E2-X5MCj/Bj E2E2-X10MCj/Bj E2E2-X18MCj/Bj Sensing distance (mm) Side length of sensing object d (mm) Sensing distance (mm) Sensing distance (mm) Side length of sensing object d (mm) Side length of sensing object d (mm) Mild steel Stainless steel (SUS304) Brass Aluminum Mild steel Stainless steel (SUS304) Brass Aluminum Mild steel Stainless steel (SUS304) Brass Aluminum
E2E2 3-Wire DCE2E2 3-Wire DC Dimensions Unit: mm (inch) J PRE-WIRED SENSORS E2E2-X2jj E2E2-X5Mjj E2E2-X5jj E2E2-X10Mjj Operation indicator Two clamping nut T oothed washer M12 × 1 21 dia. (0.83) Operation indicator Two clamping nut T oothed washer 9d i a . M12 × 1 M18 × 1 T oothed washer Two clamping nut Operation indicator 14.8 dia. M18 × 1 T oothed washer Two clamping nut Operation indicator Round vinyl-insulated cable 4 dia. (0.08 dia. x 60) 2/3 cores Standard length: 2 m Round vinyl-insulated cable 4 dia. (0.08 dia. x 60) 2/3 cores Standard length: 2 m Round vinyl-insulated cable 6 dia. (0.12 dia. x 45) 2/3 cores Standard length: 2 m Round vinyl-insulated cable 6 dia. (0.12 dia. x 45) 2/3 cores Standard len gth: 2 m 60 (2.36) 55 (2.17) 21 dia. (0.83) 60 (2.36) 55 (2.17) (0.28) 29 dia. (1.14) 65 (2.56) 60 (2.36) 29 dia. (1.14) 65 (2.56) 60 (2.36) (0.39) (0.51) E2E2-X10jj E2E2-X18Mjj M30 × 1.5 T oothed washer Two clamping nut Operation indicator Round vinyl-insulated cable 6 dia. (0.12 dia. x 45) 2/3 cores Standard length: 2 m M30 × 1.5 Operation indicator Two clamping nut T oothed washer 26.8 dia. Round vinyl-insulated cable 6 dia. (0.12 dia. x 45) 2/3 cores Standard length: 2 m 42 dia. (1.65) 70 (2.76) 65 (2.56) 42 dia. (1.65) 70 (2.76) 65 (2.56)
E2E2 3-Wire DC E2E2 3-Wire DC J SENSORS WITH M12 CONNECTORS (0.28) E2E2-X2Cj-M1/Bj-M1 E2E2-X5MCj-M1/Bj-M1 E2E2-X5Cj-M1/Bj-M1 E2E2-X10MC j-M1/Bj-M1 Operation indicator Two clamping nut T oothed washer M12 x 1 M12 x 1 Operation indicator Two clamping nut T oothed washer M12 x 1 M12 x 19d i a . Operation indicator Two clamping nut T oothed washer M12 x 1 M18 x 1 M12 x 1 M18 x 1 Operation indicator Two clamping nut T oothed washer 14.8 dia. 21 dia. (0.83) 70 (2.76) 55 (2.17) 21 dia. (0.83) 70 (2.76) 55 (2.17) 29 dia. (1.14) 75 (2.95) 60 (2.36) 29 dia. (1.14) 75 (2.95) 60 (2.36) 17 4 10 17 4 10 24 4 10 24 41 010 (0.39) 65 (2.56) 80 (3.15) E2E2-X10Cj-M1/Bj-M1 M30 x 1.5 Operation indicator Two clamping nut T oothed washer M12 x 1 E2E2-X18MCj-M1/Bj-M1 M30 x 1.5 Operation indicator Two clamping nut T oothed washer M12 x 1 26.8 dia. 42 dia. (1.65) (0.51) 42 dia. (1.65) 80 (3.15) 65 (2.56) 36 51 0 36 5 10 J MOUNTING HOLES F Dimensions M12 M18 M30
E2E2 3-Wire DCE2E2 3-Wire DC Installation J PIN ARRANGEMENT E2E2-XjBj-M1 DC 3-wire Models Output configuration Applicable models Pin arrangement NO E2E2-XjB1-M1 Note: Terminal 2 is not used. Load E2E2-XjC1-M1 Note: Terminal 2 is not used. Load NC E2E2-XjB2-M1 Note: Terminal 4 is not used. Load E2E2-XjC2-M1 Note: Terminal 4 is not used. Load Precautions J MOUNTING Do not tighten the nut with excessive force. A washer must be used with the nut. Shielded Model Unshielded Model Part B Part A Part B Part A Note: The table below shows the tightening torques for part A and part B nuts. In the previous examples, the nut is on the sen- sor head side (part B) and hence the tightening torque for part B applies. If this nut is in part A, the tightening torque for part A applies instead. Type Torque M12 30 NS m (310 kgfS cm) M18 70 NS m (710 kgfS cm) M30 180 NS m (1,800 kgfS cm)
E2E2 3-Wire DC E2E2 3-Wire DC J EFFECTS OF SURROUNDING METAL When mounting the E2E2 within a metal panel, ensure that the clearances given in the table below are maintained. Failure to maintain these distances may cause deterioration in the perfor- mance of the sensor. dd i a . Type Dimension M12 M18 M30 Shielded ℓ 0m m 0m m 0m m d 12 mm 18 mm 30 mm D 0m m 0m m 0m m m 8m m 20 mm 40 mm n 18 mm 27 mm 45 mm Unshielded ℓ 15 mm 22 mm 30 mm d 40 mm 55 mm 90 mm D 15 mm 22 mm 30 mm m 20 mm 40 mm 70 mm n 36 mm 54 mm 90 mm J MUTUAL INTERFERENCE When installing two or more Sensors face to face or side by side, ensure that the minimum distances given in the following table are maintained. A B Type Dimension M12 M18 M30 Shielded A 30 mm 50 mm 100 mm B 20 mm 35 mm 70 mm Unshielded A 120 mm 200 mm 300 mm B 100 mm 110 mm 200 mm J INSTALLATION Power Reset Time The Proximity Sensor is ready to operate within 100 ms after power is supplied. If power supplies are connected to the Proximity Sensor and load respectively, be sure to supply power to the Proximity Sensor before supplying power to the load. Power OFF The Proximity Sensor may output a pulse signal when it is turned off. Turn off the load before turning off the Proximity Sensor. Power Supply Transformer When using a DC power supply, make sure that the DC power supply has an insulated transformer. Do not use a DC power supply with an auto-transformer. Target Object Metal Coating The sensing distances of the Proximity Sensor vary with the metal coating on target objects. J WIRING High-tension Lines Wiring through Metal Conduit If there is a power or high-tension line near the cable of the Proximity Sensor, wire the cable through an independent metal conduit to prevent against Proximity Sensor damage or malfunctioning. Cable Tractive Force Do not pull cables with the tractive forces exceeding these specs. Diameter Tractive force 4m md i a .m a x . 30 N max. 4 mm dia. min. 50 N max. J MOUNTING The Proximity Sensor must not be subjected to excessive shock with a hammer when it is installed, or the Proximity Sensor may be damaged or lose its water-resistance. J ENVIRONMENT Water Resistance Do not use the Proximity Sensor underwater, outdoors, or in the rain. Operating Environment Be sure to use the Proximity Sensor within its operating ambient temperature range and do not use the Proximity Sensor outdoors so that its reliability and life expectancy can be maintained. Although the Proximity Sensor is water resistant, a cover to pro- tect the Proximity Sensor from water or water-soluble machining oil is recommended so that its reliability and life expectancy can be maintained. Do not use the Proximity Sensor in an environment with chemical gas (e.g., strong alkaline or acid gasses including nitric, chromic, and concentrated sulfuric acid gases).
Schaumburg, IL 60173 NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4. 1-800-55-OMRON OMRON CANADA, INC.
885 Milner Avenue
Scarborough, Ontario M1B 5V8 416-286-6465 R OMRON ON- -LINE Global - -http://www.omron.com USA - -http://www.omron.com/oei Canada - -http://www.omron.com/oci E2E2 3-Wire DC E2E2 3-Wire DC