Applicable All models E2C-CR8A, E2C-CR8B, E2C-X1A, E2C-CR5B sensors E2C-C1A, E2C-X1R5A Supply 90 to 264 VAC, 10 to 30 VDC 10 to 30 VDC voltage 50/60 Hz Output type Transistor Open collector NPN PNP NPN PNP and relay NPN and PNP Part number E2C-AK4A E2C-AM4A E2C-GE4A E2C-GF4A E2C-GE4B E2C-GF4B Sensor type Shielded Part number E2C-CR5B E2C-CR8A E2C-CR8B E2C-X1A E2C-C1A Miniature Inductive Prox E2C Sensor type Shielded Unshielded Size M8 M12 M18 M30 40 mm dia. Part number E2C-X1R5A E2C-X2A E2C-X5A E2C-X10A E2C-C20MA I AMPLIFIERS Socket-Mount Types Standard Sizes I SENSORS Miniature Sizes I Separate amplifier allows sensor to fit in space-confined sites, providing easy access for monitoring and remote adjustments I Detecting distance and differential travel can be adjusted to meet specific application requirements I Adjustable differential travel to set switching trigger point available on some amplifiers Cylindrical Inductive Sensors with Separate Amplifiers Provide Variable Detecting Capabilities
Ordering Information
Size Prewired Screw terminal Applicable sensors E2C-CR8A, E2C-X1A, E2C-C1A E2C-CR8A, E2C-X1A, E2C-X1R5A, E2C-X2A E2C-C1A, E2C-X1R5A Supply voltage 10 to 30 VDC, Output type NPN with alarm output Open collector NPN and PNP Part number E2C-JC4AP E2C-WH4AF Description Part number Fits M5 size sensors (supplied with each sensor) M5-MHWS Fits M8 size sensors (supplied with each sensor) M8-MHWS Fits M12 size sensors (supplied with each sensor) M12-MHWS Fits M18 size sensors (supplied with each sensor) M18-MHWS Fits M30 size sensors (supplied with each sensor) M30-MHWS Mounting hardware includes one pair of metal nuts and washers I REPLACEMENT PARTS Description Part number Mounting brackets Fits 3.5 mm and 3.8 mm dia. unthreaded sensor Y92E-F3R5 Fits M8 size threaded sensor Y92E-B8 Fits M12 size threaded sensor Y92E-B12 Fits M18 size threaded sensor Y92E-B18 Fits M30 size threaded sensor Y92E-B30 Sockets for E2C-AK4A Bottom surface or track mounting, top screw terminals P2CF-11 Panel mounting, bottom solder terminal PL11 Back mounting, for use with Y92F-30 mounting adapter, bottom screw terminalsP3G-11 E2C-AM4A Bottom surface or track mounting, top screw terminals P2CF-08 Panel mounting, bottom solder terminals PL08 Back mounting, for use with Y92F-30 mounting adapter, bottom screw terminalsP3G-08 E2C-G ❑ 4❑ Bottom surface or track mounting, top screw terminals PYF08A-E Panel mounting, bottom solder terminals PY08 Bottom surface mounting, bottom screw terminals PYF08M Panel mounting adapters Fits behind panel; ideal for side by side installation. Y92F-30 for E2C-A❑ 4A amplifiers Use P2CF- ❑❑ sockets. Installs through panel front; amplifier face fits bezel, rear of amplifier clipsY92F-70 to adapter. Use P3G-❑❑ sockets. Charcoal gray. Protective covers Hard plastic cover; not for use with Y92F-70 panel adapter Y92A-48 Soft plastic cover; not for use with Y92F-70 panel adapter Y92A-48D Mounting track DIN rail, 50 cm (1.64 ft) length PFP-50N DIN rail, 1 m (3.28 ft) length PFP-100N End plate PFP-M Spacer PFP-S for sensors amplifiers amplifier amplifier amplifiers for E2C-A❑ 4A amplifiers I ACCESSORIES
Part number E2C-CR5B E2C-CR8A E2C-CR8B E2C-X1A E2C-C1A Sensor type Inductive Type Shielded Required amplifier E2C-AK4A, E2C-AK4A, E2C-AM4A, E2C-GE4A, E2C-AM4A, E2C-GF4A, E2C-JC4AP or E2C-WH4AF E2C-GE4B or E2C-GF4B Detectable object type Metallic objects 0 to 0.5 mm 0 to 0.8 mm 0 to 1.0 mm (0 to 0.02 in) (0 to 0.03 in) (0 to 0.04 in) Usable setting distance at 0 to 0.7 mm 0 to 1.2 mm 0 to 1.5 mm 0° to 40°C (with standard target) (0 to 0.028 in) (0 to 0.047 in) (0 to 0.059 in) Standard target size 5 x 5 x 1 mm (mild steel, L x W x H) (0.20 x 0.20 x 0.04 in) Differential travel See "Differential Travel" tables Response frequency 1 kHz Materials Housing 304 stainless steel Nickel-plated brass Sensing face ABS Cable sheath Polyethylene Mounting — Optional mounting strap Two lock washers — Y92E-F3R5, order separately and M5 nuts included Connections Prewired Two-conductor cable, 3 m (9.8 ft) length UL — NEMA 1,2 1, 3, 4, 6, 12, 13 IEC 144 IP64 IP67 Approvals UL — CSA — Ambient operating temperature -25° to 70°C (-13° to 158°F) Vibration 10 to 55 Hz, 1.5 mm (0.06 in) double amplitude, 2 hours each, X and Y directions Shock 50 G's, 3 times each, X and Y directions Usable setting distance at ambient (with standard target) Enclosure ratings I MINIATURE SENSORS
Part number E2C-X1R5A E2C-X2A E2C-X5A E2C-X10A E2C-C20MA Sensor type Inductive Body Size M8 M12 M18 M30 40 mm dia. Type Shielded Unshielded Required amplifier E2C-JC4AP, E2C-AK4A or E2C-AM4A E2C-AK4A or E2C-AM4A Detectable object type Metallic objects 0 to 1.5 mm 0 to 2 mm 0 to 5 mm 0 to 10 mm 0 to 20 mm Usable setting distance 0 to 2 mm 0 to 2.5 mm 0 to 7 mm 0 to 15 mm 0 to 28 mm Standard target size 8 x 8 x 1 mm 12 x 12 x 1 mm 18 x 18 x 1 mm 30 x 30 x 1 mm 50 x 50 x 1 mm Differential travel See "Differential Travel" tables Response frequency 800 Hz 350 Hz 100 Hz 50 Hz Materials Housing Nickel-plated brass Sensing face ABS Cable sheath Polyethylene Mounting Two lock washers Two lock washers Two lock washers Two lock washers — and M8 nuts and M12 nuts and M18 nuts and M30 nuts included. Bracket included. Bracket included. Bracket included. Bracket Y92E-B8 optional. Y92E-B12 optional. Y92E-B18 optional. Y92E-B30 optional. Connections Prewired Two-conductor cable, 3 m (9.8 ft) length UL — NEMA 1, 3, 4, 6, 12, 13 IEC 144 IP67 Approvals UL — CSA — Ambient operating temperature -25° to 70°C (-13° to 158°F) Vibration 10 to 55 Hz, 1.5 mm (0.06 in) double amplitude, 2 hours each, X and Y directions Shock 50 G's, 3 times each, X and Y directions Usable setting distance at ambient (with standard target) I STANDARD SIZE SENSORS Enclosure ratings
Part number E2C-AK4A E2C-AM4A E2C-GE4A E2C-GF4A E2C-GE4B E2C-GF4B Supply voltage 90 to 264 VAC, 10 to 30 VDC 50/60 Hz Current consumption 55 mA max. 25 mA max. Differential travel See "Differential Travel" tables Control Relay Type SPDT — Max. load 2 A, 250 VAC — (p.f. = 1) Min. load 1 mA, 5 VDC — DC Type Transistor, One NPN open NPN open PNP open NPN open PNP open solid- SPST collector, one collector with collector with collector with collector with state PNP open pull-up pull-down pull-up pull-down collector Max. load 50 mA, 40 VDC 200 mA 100 mA Max. on-state 2 VDC 1.5 VDC voltage drop Indicators Output Operation (red LED) and Output Operation (red LED) Output Stability (red LED) Materials Case Plastic Mounting Requires Requires Requires PYF08A-E, PY08 or PYF08M socket P2CF-11, P2CF-08, (not included). Order separately from Accessories. PL11 or P3G-11 PL08 or P3G-08 socket (not socket (not included). Order included). Order separately from separately from Accessories. Accessories. Connections Plated steel screw terminals or solder terminals, refer to sockets in Accessories section. Enclosure UL — NEMA 1 IEC 144 IP 40 Approvals UL — CSA — Ambient operating temperature -10° to 55°C (14° to 131°F) Vibration 10 to 25 Hz, 2 mm (0.08 in) double amplitude, 2 hours each, X and Y directions Shock 10 G's, 3 times each, X and Y directions output ratings
Amplifier Sensor Differential travel part part (% of detecting distance) At minimum At maximum detecting detecting distance distance E2C-G ❑ 4A E2C-CR8A,8B 2.0 to 4.7%, 3.8 to 6.0%, fixed fixed fixed fixed fixed fixed E2C-X1R5A 1.7 to 4.2%, 2.7 to 6.0%, fixed fixed E2C-G ❑ 4B E2C-CR5B 1.6 to 17.6%, 4.4 to 19.2%, fixed fixed E2C-JC4AP, E2C-CR8A 2.0 to 4.7%, 3.8 to 6.0%, E2C-WH4AF fixed fixed fixed fixed fixed fixed E2C-X1R5A 1.7 to 4.2%, 2.7 to 6.0%, fixed fixed I DIFFERENTIAL TRAVEL E2C-AK4A and E2C-AM4A amplifiers number number Amplifier Sensor Differential travel part part (% of detecting distance) At minimum At maximum detecting detecting distance distance E2C-AK4A E2C-CR5B 1 to 5%, 1 to 5%, E2C-CR8A adjustable adjustable E2C-CR8B E2C-X1A E2C-C1A E2C-X1R5A E2C-X2A E2C-X5A E2C-X10A E2C-C20MA E2C-AM4A E2C-CR5B 1 to 5%, 1 to 5%, E2C-CR8A adjustable adjustable E2C-CR8B E2C-X1A E2C-C1A E2C-X1R5A E2C-X2A E2C-X5A E2C-X10A E2C-C20MA number number E2C-G ❑ 4A, E2C-G❑ 4B and E2C-WH4AF amplifiers Part number E2C-JC4AP E2C-WH4AF Supply voltage 10 to 30 VDC Current consumption 45 mA 25 mA Differential travel See "Differential Travel" tables Control DC Type NPN open collector One NPN open collector, one PNP open collector Max. load 100 mA 200 mA Max. on-state 1 VDC 0.7 VDC voltage drop Alarm output Type NPN open collector Not provided Max. load 50 mA — Indicators Output Operation (red LED), Output Operation (red LED) Output Stability (green LED) Materials Case Plastic Mounting DIN rail track, E39-L48 mounting bracket, DIN rail track or bottom surface with or two side through holes two through holes Connections Prewired, 4-conductor cable, 2 m (6.56 ft) length Terminal screws or direct connection to S308 sensor controller with E99-C connector (included). Weight 80 g (2.8 oz.) with cable 80 g (2.8 oz.) with cable Enclosure UL — NEMA 1 IEC 144 IP 40 Approvals UL — CSA — Ambient operating temperature -10° to 55°C (14° to 131°F) Vibration 10 to 25 Hz, 2 mm (0.08 in) double amplitude, 2 hours each, X and Y directions Shock 10 G's, 3 times each, X and Y directions output solid- state Track-Mount Type ratings
AC input, transistor and relay outputs E2C-AM4A Amplifier DC input, open collector NPN and PNP outputs Main circuit 50 mA max. 2.2Ω Output (+) Output (-) 47 V Main circuit 200 mA max. 47 V 2.2Ω 2.2Ω47 V Output 1 (NPN) Output 2 (PNP) +12 to 24 VDC 47 V 2.2Ω 200 mA max. Output when connected to S3D8 sensor controllers E2C-WH4AF Amplifier DC input, open collector NPN and PNP outputs E2C-GE4 ❑ Amplifiers DC input, NPN or PNP outputs Main circuit 47 V 2.2Ω 100 mA max. 0V Output (+) +12 to 24 VDC 3.9kΩ Main circuit +12 to 24 VDC Output 2 (NPN) Output 1 (PNP) 47 V 200 mA max. 2.2Ω 47 V E2C-GF4 ❑ Amplifiers DC input, NPN and PNP outputs Main circuit +12 to 24 VDC Output2.2Ω 47 V 3.9kΩ 100 mA max. E2C-JC4AP Amplifier DC input, open collector NPN output with alarm Main circuit 2.2Ω 3.9Ω DC 10 to 30 VDC 100 mA max. output Load Red White Black ZD ZD Alarm output 50 mA max. Yellow Z D : VZ = 40 V Operation
Shielded 2 mm dia. sensor E2C-CR5B Shielded 3.5 mm & 3.8 mm dia. sensor E2C-CR8A, E2C-CR8B Shielded M5 and 5.4 mm dia. sensors E2C-X1A, E2C-C1A Y (mm) -10 -8 -6 -4 -2 0 2 4 6 8 10 ÷ ÷E2C-X5A detecting headY (mm) -6 -4 -2 0 2 4 6 ÷ Y (mm)÷E2C-X2A detecting head 2.5 2.0 1.5 1.0 0.5 3.0 2.0 1.0 0-4 -3 -2 -1 0 1 2 3 4 ÷ ÷ Y (mm) 0.5 0.4 0.3 0.2 0.1 ÷ ÷ Y (mm) 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 ÷ ÷ Y (mm) 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 ÷ ÷E2C-X1A detecting head ÷ ÷ Shielded M8 sensor E2C-X1R5A Shielded M12 sensor E2C-X2A Shielded M18 sensor E2C-X5A Shielded M30 sensor E2C-X10A Unshielded 40 mm dia. sensor E2C-C20MA 0 -15 -10 -5 0 5 10 15 ÷ ÷E2C-X10A detecting head Y (mm) ÷ Y (mm)E2C-C20MA detecting head ÷ -20 -15 -10 -5 0 5 10 15 20 25 Detecting distance X (mm) Detecting distance X (mm) Detecting distance X (mm) Detecting distance X (mm) Detecting distance X (mm) Detecting distance X (mm) Detecting distance X (mm) Detecting distance X (mm) E2C-C1A detecting head Detecting distance (variable): 0.2 to 0.5 mm X Y 100% 50% 20% Detecting distance (variable): 0.2 to 1 mm X Y 20% 50% 100% 100% 50% 20% X Y X Y Detecting distance (variable): 0.3 to 1.5 mm 100% 50% 20% X Detecting distance (variable): 0.4 to 2 mm 100% 50% 20% X Y Detecting distance (variable): 1 to 5 mm 100% 50% 20% X Y 100% 50% 20% Detecting distance (variable): 2 to 10 mm X Y Detecting distance (variable): 4 to 20 mm 100% 50% 20% Detecting distance (variable): 0.16 to 0.8 mm Y E2C-CR5B detecting head 2 dia. E2C-CR8A detecting head E2C-X1R5A detecting head
I DETECTING DISTANCE vs. SIZE AND MATERIAL OF TARGET Shielded 2 mm dia. sensor E2C-CR5B Shielded 3.5 mm & 3.8 mm dia. sensor E2C-CR8A, E2C-CR8B Shielded M5 and 5.4 mm dia. sensors E2C-X1A, E2C-C1A Detecting distance X (mm) Detecting distance X (mm) 1.2 1.0 0.8 0.6 0.4 0.2 Size of target (mm) 0 4 8 12 16 20 24 Size of target (mm) 2 4 6 8 10 12 14 16 18 20 22 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 Size of target (mm) Detecting distance X (mm) 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 2 4 6 8 10 12 14 16 18 20 22 2.5 2.0 1.5 1.0 0.5 Shielded M8 sensor E2C-X1R5A Shielded M12 sensor E2C-X2A Shielded M18 sensor E2C-X5A Detecting distance X (mm) Size of target (mm) 2 4 6 8 10 12 14 16 18 20 Size of target (mm) Detecting distance X (mm) 3.5 3.0 2.5 2.0 1.5 1.0 0.5 2 4 6 8 10 12 14 16 18 20 22 Detecting distance X (mm) 8.0 7.0 6.0 5.0 4.0 3.0 2.0 1.0 5 10 15 20 25 30 35 40 45 Size of target (mm) Shielded M30 sensor E2C-X10A Unshielded 40 mm dia. sensor E2C-C20MA 10 20 30 40 50 60 70 80 90 100 110 Detecting distance X (mm) Size of target (mm) Detecting distance X (mm) 16.0 14.0 12.0 10.0 8.0 6.0 4.0 2.0 5 10 15 20 25 30 35 40 45 Size of target (mm) Note: If the target is a nonferrous metal, the operating distance of the proximity sensor decreases. However, with a piece of foil measur- ing about 0.01 mm (0.0004 inch) in thickness, the detecting distance is equivalent to that with a ferrous metal. Note that the proximity sensor cannot detect extremely thin evaporated films and non-conductive targets. Mild steel t = 1 mmX X t = 1 mm Mild steel Mild steel X X Mild steel Stainless steel Brass Aluminum X t = 1 mm Mild steel Stainless steel Brass Aluminum Mild steel Stainless steel Brass Aluminum t = 1 mm X t = 1 mmX Mild steel Stainless steel Brass Aluminum X t = 1 mm Mild steel Stainless steel Brass Aluminum t = 1 mm t = 1 mm
Unit: mm (inch) I SENSORS Miniature Sizes E2C-CR5B E2C-CR8A, E2C-CR8B E2C-X1A E2C-C1A 2 (0.079) dia. 3,000 (118.1) 1.2 (0.047) dia. Shielded cable 3,000 (118.1) Coaxial cable 8 (0.32) across flats 2.5 (0.098)dia. Coaxial cableM5 x 0.5 3,000 (118.1) Coaxial cable 3,000 (118.1) 13 (0.51) across flats 18 (0.71) 8.5 (0.33) dia. Standard Sizes E2C-X1R5A 17 (0.67) across flats Coaxial cable 12.5 (0.492) dia. M12 x 1 (0.59) E2C-X2A E2C-X5A E2C-X10A 24 (0.94) across flats 27 (1.06) 18.5 (0.73) dia. Coaxial cable M18 x 1 4 (0.16) dia. 36 (1.42) across flats 30.5 (1.2) dia. M30 x 1.5 5.4 (0.21) dia. Coaxial cable E2C-C20MA (0.984) (0.86) Coaxial cable M18 x 1 40 (1.57) dia. 40 (1.57) dia. 5.5 (0.22) dia. (0.59) (0.71) (0.59) A (See Note.) 15 (0.59) 2.5 (0.098) dia. (0.71) 2.5 (0.098) dia. 3,000 (118.1) 3,000 (118.1) M8 x 1 Coaxial cable2.5 (0.098) dia. (0.118) (1.18) 3,000 (118.1) (1.96) 3,000 (118.1) 2.5 (0.098) dia. (1.57) (1.46) 3,000 (118.1) 5.4 (0.21) dia. (0.71) 5.4 (0.21) dia. Note: For E2C-CR8A, A= 3.5 mm (0.14 in) For E2C-CR8B, A=3.8 mm (0.15 in)
E2C-AK4A AC type, fits 11-pin sockets E2C-AM4A DC type, fits 8-pin sockets ❑ 48 (1.89) 84.7 (3.33) 63.5 (2.5) 3.5 (0.14) (0.24) ❑ 44.8 (1.76) 14.2 (0.56) Miniature E2C-G ❑ 4❑ 20.7 (0.81) 35.5 (1.39) 4.5 (0.18)mm dia. cable, 2 m (6.56 ft) length E2C-WH4AF Connector on either side for connection to sensor controller Slot for track mounting Two 4.5 (0.18) dia. mounting holes Two M4 holes 12.5 (0.49) M3.5 Note: When E2C-WH4AF amplifier is connected to S3D8 sensor controller, using the E99-C connector supplied, the amplifier is powered by the controller and the output is connected to the sensor controller. I TRACK-MOUNT AMPLIFIERS E2C-JC4AP 40 ms OFF-delay selector switch NO/NC mode switch Apply protective sticker hereSensitivity adjuster Stability indicator Operation indicatorM2.6 2.5 (0.10) 3.5 (0.14) 12 (0.47) 0.55 Mounting bracket E39-L48 Mounting holes 27.2 (1.07) 5.4 (0.21) (1.97) (0.39) (0.19) 43 (1.69) 60 (2.36) (1.18) (2.95) (3.15) (2.6) (2.6) [7(0.28)] (0.39) 22.5 (0.89) 2-ø3.3 (0.13)
I OPTIONAL MOUNTING BRACKETS FOR STANDARD SIZE THREADED SENSORS Part Drawing dimensions Applicable ABC D EF sensor models 7.8 (0.31) Eleven M3.5 x 7.5 sems Two 4.5 (0.18) dia. mounting holes 4.5 (0.18) 4 (Top view) Mounting holes PL11 Panel mounting socket Mounting holes (Bottom view) Two 3.5 (0.14) dia. or two M3 socket mounting holes 40 (1.57) ± 0.3 3.5 (0.14) Approx. 20.5 (0.80) 4 (0.16) 1 (0.04) Two 2 dia. holes P3G-11 Back mounting socket Terminal arrangement Terminal arrangement Terminal arrangement 31 dia. hole 11-Pin Sockets for E2C-AK4A Amplifier P2CF-11 Bottom surface or track mounting socket I SOCKETS FOR AMPLIFIERS (Bottom view) 27(1.06) dia. (1.77) 4.5 (0.18) 5 (0.20) 9 (0.35) 8 (0.31) Eight M3.5 x 7.5 sems Two 4.5 (0.18) dia. mounting holes 7.8 (0.31) 20 (0.79) max. 3 (0.12) 35.4 (1.39) 4.5 (0.18) 8-Pin Sockets for E2C-AM4A Amplifier P2CF-08 Bottom surface or track mounting socket (Top view) Mounting holes Two 4.5 (0.18) dia. or two M4 socket mounting holes Terminal arrangement 70 (2.75) max. 50 (1.97) max. (0.12) 35.4 (1.39) (1.22) max. (1.57) ± 0.2 (2.00) max. (1.38) max. 26.6 (1.05) (1.77) (0.28) 70 (2.76) max. 50 (1.97) max. (1.57) 17.5 (0.69) F B E D A C number (0.16) 40 (1.57) ± 0.2 Two 4.5 (0.18) dia. socket mounting holes
8-Pin Sockets for E2C-AM4A Amplifier (continued) PL08 Panel mounting socket 30 (1.18)dia. 3.9 (0.15) P3G-08 Back mounting socket (1.06) dia. 17.5 (0.69) 9 (0.35) 8 (0.32) (Bottom view) Approx. 20.5 (0.81) Eight M3 x 8 sems (0.91) max. 4 (0.16) 35.4 (1.39) 3.4 (0.13) Two 4.2 dia. x 5 mounting holes PY08 Panel mounting socket Eight-3 x 1.2 elliptic holes Eight-3 x 1.2 elliptic holes 20 (0.79)max. PYF08M Bottom surface mounting socket Eight M3.5 sems 3.5 (0.14) dia. mounting hole 6.5 (0.26) dia. spot facing Depth: 11.5 (0.45) 40 (1.57) max. 3 (0.12)dia. 1.5 (0.06) (Bottom view) Mounting holes Two 3.5 (0.14) dia. or two M3 socket mounting holes hole Sockets for E2C-G❑ 4❑ Amplifiers PYF08A-E Bottom surface or track mounting socket (Bottom view) Two M3 or M4 or 4.5 (0.18) dia. socket mounting holes Mounting holes 59 (2.32) ± 0.3 15 (0.59) ± 0.2 (Bottom view) Panel cutout 21.4 (0.84) + 0.2 25.8 (1.02) + 0.2 (Top view) Mounting holes 3.5 (0.14) dia. socket mounting hole 3.5 (0.14) dia. or M3 socket mounting hole Terminal arrangement Terminal arrangement Terminal arrangement Terminal arrangement Terminal arrangement 50.5 (1.99) max. (1.57) 3.5 (0.14) 35 (1.38) max. (0.63) 45 (1.77) (1.77) 4.5 (0.17) (0.28) (0.24) 72 (2.83) max. 2.7 (0.11) 7.7 (0.30) 24 (0.94) max. 44.5 (1.75) max. 18 (0.71)max. 20 (0.78) ± 0.1 6 (0.24) max. 29.5 (1.16)max. 25.5 (1.00) max. 2.6 (0.10) 7 (0.28) Two 2 (0.08) dia. holes
For E2C-A❑ 4A Amplifiers Y92F-30 Mounting adapter Adapter installs behind the panel. It is ideal for side by side installation. Use P2CF-❑❑ sockets Y92F-70 Mounting adapter Charcoal gray panel adapter installs through panel front. Amplifier face fits bezel, rear of amplifier clips to adapter. Use P3G-❑❑ sockets. Note: Recommended panel thickness is 1 to 3.2 mm. (1.89) 91.4 (3.60)6 (0.24) Mounting panel Back mounting socket P3G-❑❑ Y92F-30 adapter for flush mounting 45 (1.77) ± 0.5 (3.46) (0.63) 85.4 (3.36) Mounting panel Back mounting socket P3G-❑❑ Note: With Type H3BF-8, dimension * should read as 16.7 mm (.657"). 76 (2.99) ± 0.2 Note: Recommended panel thickness is 1 to 3.2 mm. Panel cutout I PROTECTIVE COVERS For E2C-A❑ 4A Amplifiers Y92A-48 Hard plastic cover, Y92A-48D Soft plastic cover Hard plastic cover Y92A-48 and soft plastic cover Y92A-48D snap onto the front of the amplifier to protect it from dust, dirt and water drip. The Y92A-48 hard plastic cover projects 4 mm from the front of the amplifier. Y92A-48D soft plastic cover fits snugly over the front. 11 (0.43) overall depth I MOUNTING TRACK AND ACCESSORIES PFP-100N/PFP-50N DIN Rail PFP-S Spacer 1.5 (0.06) PFP-M End Plate 1.8 (0.07) 1.3 (0.05)10 (0.39) Panel cutout15 (0.59) (2.28) 45 (1.77) ± 0.5 (1.77) ± 0.15 45 (1.77) ± 0.15 58(2.28) 52 (2.05) to 53 (2.09) 4.5 (0.18) 15 (0.59) 25 (0.98) 1000 (39.37) [500 (19.68)] (0.98) 10(0.39) 15(0.59) 7.3(0.29) ± 0.15 27(1.06) ± 0.15 (1.97) 11.5 (0.45) 6.2 (0.24) 1.8 (0.07) (0.39) 4.8 (0.19) 35.3 (1.39)37.3 (1.47) 16 (0.63) 12 (0.47) 44.3 (1.74) 34.8 (1.37) 16.5 (0.65) (0.20) 50.5 (1.99) 50.5 (1.99) 10(0.39) 0.5 (0.02) R max. 0.5 (0.02) R max. Two 4.5 (0.18) dia. mounting holes for panel adapter 65 (2.56) to 66 (2.6)