E2A Cylindrical Proximity Sensor 1 Cylindrical Proximity Sensor E2A Safe Mounting with Greater Sensing Distance
- Ensures a sensing distance approximately 1.5 to 2 times larger than that of any conventional OMRON Sensor. Problems such as the collision of workpieces are eliminated. Full range of standard sizes (M8, M12, M18 and M30; both long and short barrels) Modular construction simplifies customization. <READ AND UNDERSTAND THIS CATALOG> Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments.
Ordering Information
(overall length) Output configuration Operation mode NO Operation mode NC M8 Shielded 2.0 mm Pre-wired Stainless steel 27 (40) PNP E2A-S08KS02-WP-B1 2M E2A-S08KS02-WP-B2 2M NPN E2A-S08KS02-WP-C1 2M E2A-S08KS02-WP-C2 2M 49 (62) PNP E2A-S08LS02-WP-B1 2M E2A-S08LS02-WP-B2 2M NPN E2A-S08LS02-WP-C1 2M E2A-S08LS02-WP-C2 2M M12 connector Stainless steel 27 (43) PNP E2A-S08KS02-M1-B1 E2A-S08KS02-M1-B2 NPN E2A-S08KS02-M1-C1 E2A-S08KS02-M1-C2 49 (65) PNP E2A-S08LS02-M1-B1 E2A-S08LS02-M1-B2 NPN E2A-S08LS02-M1-C1 E2A-S08LS02-M1-C2 Brass 27 (43) PNP E2A-M08KS02-M1-B1 E2A-M08KS02-M1-B2 NPN E2A-M08KS02-M1-C1 E2A-M08KS02-M1-C2 49 (65) PNP E2A-M08LS02-M1-B1 E2A-M08LS02-M1-B2 NPN E2A-M08LS02-M1-C1 E2A-M08LS02-M1-C2 M8 connector (3- pin) Stainless steel 27 (39) PNP E2A-S08KS02-M5-B1 E2A-S08KS02-M5-B2 NPN E2A-S08KS02-M5-C1 E2A-S08KS02-M5-C2 49 (61) PNP E2A-S08LS02-M5-B1 E2A-S08LS02-M5-B2 NPN E2A-S08LS02-M5-C1 E2A-S08LS02-M5-C2 Non-shielded 4.0 mm Pre-wired Stainless steel 27 (40) PNP E2A-S08KN04-WP-B1 2M E2A-S08KN04-WP-B2 2M NPN E2A-S08KN04-WP-C1 2M E2A-S08KN04-WP-C2 2M 49 (62) PNP E2A-S08LN04-WP-B1 2M E2A-S08LN04-WP-B2 2M NPN E2A-S08LN04-WP-C1 2M E2A-S08LN04-WP-C2 2M M12 connector Stainless steel 27 (43) PNP E2A-S08KN04-M1-B1 E2A-S08KN04-M1-B2 NPN E2A-S08KN04-M1-C1 E2A-S08KN04-M1-C2 49 (65) PNP E2A-S08LN04-M1-B1 E2A-S08LN04-M1-B2 NPN E2A-S08LN04-M1-C1 E2A-S08LN04-M1-C2 Brass 27 (43) PNP E2A-M08KN04-M1-B1 E2A-M08KN04-M1-B2 NPN E2A-M08KN04-M1-C1 E2A-M08KN04-M1-C2 49 (65) PNP E2A-M08LN04-M1-B1 E2A-M08LN04-M1-B2 NPN E2A-M08LN04-M1-C1 E2A-M08LN04-M1-C2 M8 connector (3- pin) Stainless steel 27 (39) PNP E2A-S08KN04-M5-B1 E2A-S08KN04-M5-B2 NPN E2A-S08KN04-M5-C1 E2A-S08KN04-M5-C2 49 (61) PNP E2A-S08LN04-M5-B1 E2A-S08LN04-M5-B2 NPN E2A-S08LN04-M5-C1 E2A-S08LN04-M5-C2
2 E2A Cylindrical Proximity Sensor
Note: M30 non-shielded Models with double sensing distance and short barrels cannot be mounted due to the necessary separation distance from the surrounding metal. Standard sensing models are thus available. M12 Shielded 4.0 mm Pre-wired Brass 34 (50) PNP E2A-M12KS04-WP-B1 2M E2A-M12KS04-WP-B2 2M NPN E2A-M12KS04-WP-C1 2M E2A-M12KS04-WP-C2 2M 56 (72) PNP E2A-M12LS04-WP-B1 2M E2A-M12LS04-WP-B2 2M NPN E2A-M12LS04-WP-C1 2M E2A-M12LS04-WP-C2 2M M12 connector Brass 34 (48) PNP E2A-M12KS04-M1-B1 E2A-M12KS04-M1-B2 NPN E2A-M12KS04-M1-C1 E2A-M12KS04-M1-C2 56 (70) PNP E2A-M12LS04-M1-B1 E2A-M12LS04-M1-B2 NPN E2A-M12LS04-M1-C1 E2A-M12LS04-M1-C2 Non-shielded 8.0 mm Pre-wired Brass 34 (50) PNP E2A-M12KN08-WP-B1 2M E2A-M12KN08-WP-B2 2M NPN E2A-M12KN08-WP-C1 2M E2A-M12KN08-WP-C2 2M 56 (72) PNP E2A-M12LN08-WP-B1 2M E2A-M12LN08-WP-B2 2M NPN E2A-M12LN08-WP-C1 2M E2A-M12LN08-WP-C2 2M M12 connector Brass 34 (48) PNP E2A-M12KN08-M1-B1 E2A-M12KN08-M1-B2 NPN E2A-M12KN08-M1-C1 E2A-M12KN08-M1-C2 56 (70) PNP E2A-M12LN08-M1-B1 E2A-M12LN08-M1-B2 NPN E2A-M12LN08-M1-C1 E2A-M12LN08-M1-C2 M18 Shielded 8.0 mm Pre-wired Brass 39 (59) PNP E2A-M18KS08-WP-B1 2M E2A-M18KS08-WP-B2 2M NPN E2A-M18KS08-WP-C1 2M E2A-M18KS08-WP-C2 2M 61 (81) PNP E2A-M18LS08-WP-B1 2M E2A-M18LS08-WP-B2 2M NPN E2A-M18LS08-WP-C1 2M E2A-M18LS08-WP-C2 2M M12 connector Brass 39 (53) PNP E2A-M18KS08-M1-B1 E2A-M18KS08-M1-B2 NPN E2A-M18KS08-M1-C1 E2A-M18KS08-M1-C2 61 (75) PNP E2A-M18LS08-M1-B1 E2A-M18LS08-M1-B2 NPN E2A-M18LS08-M1-C1 E2A-M18LS08-M1-C2 Non-shielded 16.0 mm Pre-wired Brass 39 (59) PNP E2A-M18KN16-WP-B1 2M E2A-M18KN16-WP-B2 2M NPN E2A-M18KN16-WP-C1 2M E2A-M18KN16-WP-C2 2M 61 (81) PNP E2A-M18LN16-WP-B1 2M E2A-M18LN16-WP-B2 2M NPN E2A-M18LN16-WP-C1 2M E2A-M18LN16-WP-C2 2M M12 connector Brass 39 (53) PNP E2A-M18KN16-M1-B1 E2A-M18KN16-M1-B2 NPN E2A-M18KN16-M1-C1 E2A-M18KN16-M1-C2 61 (75) PNP E2A-M18LN16-M1-B1 E2A-M18LN16-M1-B2 NPN E2A-M18LN16-M1-C1 E2A-M18LN16-M1-C2 M30 Shielded 15.0 mm Pre-wired Brass 44 (64) PNP E2A-M30KS15-WP-B1 2M E2A-M30KS15-WP-B2 2M NPN E2A-M30KS15-WP-C1 2M E2A-M30KS15-WP-C2 2M 66 (86) PNP E2A-M30LS15-WP-B1 2M E2A-M30LS15-WP-B2 2M NPN E2A-M30LS15-WP-C1 2M E2A-M30LS15-WP-C2 2M M12 connector Brass 44 (58) PNP E2A-M30KS15-M1-B1 E2A-M30KS15-M1-B2 NPN E2A-M30KS15-M1-C1 E2A-M30KS15-M1-C2 66 (80) PNP E2A-M30LS15-M1-B1 E2A-M30LS15-M1-B2 NPN E2A-M30LS15-M1-C1 E2A-M30LS15-M1-C2 Non-shielded 20.0 mm Pre-wired Brass 44 (64) (See note.) PNP E2A-M30KN20-WP-B1 2M E2A-M30KN20-WP-B2 2M NPN E2A-M30KN20-WP-C1 2M E2A-M30KN20-WP-C2 2M 30.0 mm 66 (86) PNP E2A-M30LN30-WP-B1 2M E2A-M30LN30-WP-B2 2M NPN E2A-M30LN30-WP-C1 2M E2A-M30LN30-WP-C2 2M 20.0 mm M12 connector Brass 44 (58) (See note.) PNP E2A-M30KN20-M1-B1 E2A-M30KN20-M1-B2 NPN E2A-M30KN20-M1-C1 E2A-M30KN20-M1-C2 30.0 mm 66 (80) PNP E2A-M30LN30-M1-B1 E2A-M30LN30-M1-B2 NPN E2A-M30LN30-M1-C1 E2A-M30LN30-M1-C2 Size Sensing distance Connection Body material Thread length (overall length) Output configuration Operation mode NO Operation mode NC
E2A Cylindrical Proximity Sensor 3 ■Model Number Legend Example: E2A-M12LS04-M1-B1 Standard, M12, long barrel, shielded, Sn=4 mm, M12 connector, PNP-NO E2A-M08KN04-WP-B1 5M Standard, M8, short barrel, non-shielded, Sn=4 mm, pre-wired PVC cable, PNP-NO, cable length=5 m 1. Basic name E2A 2. Sensing technology Blank: Standard double distance 3. Housing shape and material M: Cylindrical, metric threaded, brass S: Cylindrical, metric threaded, stainless steel 4. Housing size 08: 8 mm 12: 12 mm 18: 18 mm 30: 30 mm 5. Barrel length K: Standard length L: Long body 6. Shield S: Shielded N: Non-shielded 7. Sensing distance Numeral: Sensing distance: e.g. 02=2 mm, 16=16 mm 8. Kind of connection WP: Pre-wired, PVC M1: M12 connector (4-pole) M3: M8 connector (4-pole) M5: M8 connector (3-pole) 9. Power source and output B: DC, 3-wire, PNP open collector C: DC, 3-wire, NPN open collector D: DC, 2-wire E: DC, 3-wire, NPN voltage output F: DC, 3-wire, PNP voltage output 10.Operation mode 1: Normally open (NO) 2: Normally closed (NC) 11.Specials (e.g., cable material, oscillating frequency) 12.Cable length Blank: Connector type Numeral: Cable type 2 3 4 5 6 7 8 9 10 111 12
4 E2A Cylindrical Proximity Sensor
■DC 3-wire Models Note 1. The response frequency is an average value. Measurement conditions are as follows: standard target, a distance of twice the standard target distance between targets, and a setting distance of half the sensing distance. 2. When using any model at an ambient temperature between −40°C and −25°C and a power voltage between 30 and 32 VDC, use a load current of 100 mA max., 3. For USA and CANADA : use class 2 circuit only. Size M8 M12 Type Shielded Non-shielded Shielded Non-shielded Item E2A-M08@S02-M1-B1 E2A-M08@S02-M1-B2 E2A-M08@S02-M1-C1 E2A-M08@S02-M1-C2 E2A-S08@S02-@@-B1 E2A-S08@S02-@@-B2 E2A-S08@S02-@@-C1 E2A-S08@S02-@@-C2 E2A-M08@N04-M1-B1 E2A-M08@N04-M1-B2 E2A-M08@N04-M1-C1 E2A-M08@N04-M1-C2 E2A-S08@N04-@@-B1 E2A-S08@N04-@@-B2 E2A-S08@N04-@@-C1 E2A-S08@N04-@@-C2 E2A-M12@S04-@@-B1 E2A-M12@S04-@@-B2 E2A-M12@S04-@@-C1 E2A-M12@S04-@@-C2 E2A-M12@N08-@@-B1 E2A-M12@N08-@@-B2 E2A- M12@N08-@@-C1 E2A-M12@N08-@@-C2 Sensing distance 2 mm ± 10% 4 mm ± 10% 4 mm ± 10% 8 mm ± 10% Setting distance 0 to 1.6 mm 0 to 3.2 mm 0 to 3.2 mm 0 to 6.4 mm Differential travel 10% max. of sensing distance Target Ferrous metal (The sensing distance decreases with non-ferrous metal.) Standard target (mild steel ST37) 8×8×1 mm 12×12×1 mm 12×12×1 mm 24×24×1 mm Response frequency (See note 1.) 1,500 Hz 1,000 Hz 1,000 Hz 800 Hz Power supply voltage (operating voltage range) 12 to 24 VDC. Ripple (p-p): 10% max. (10 to 32 VDC) Current consumption (DC 3-wire) 10 mA max. Output type -B models: PNP open collector -C models: NPN open collector Control output Load current (See note 2.) 200 mA max. (32 VDC max.) Residual voltage 2 V max. (under load current of 200 mA with cable length of 2 m) Indicator Operation indicator (Yellow LED) Operation mode (with sensing object approaching) -B1/-C1 models: NO -B2/-C2 models: NC For details, refer to the timing charts. Protection circuit Power source circuit reverse polarity protection, Surge suppressor, Short-circuit protection Output reverse polarity protection, Power source circuit reverse polarity protection, Surge suppres- sor, Short-circuit protection Ambient air temperature Operating: −40°C to 70°C, Storage: −40°C to 85°C (with no icing or condensation) Temperature in fluence (See note 2.) ±10% max. of sensing distance at 23°C within temperature range of −25°C to 70°C ±15% max. of sensing distance at 23°C within temperature range of −40°C to 70°C Ambient humidity Operating: 35% to 95%, Storage: 35% to 95% Voltage influence ±1% max. of sensing distance in rated voltage range ±15% Insulation resistance 50 MΩ min. (at 500 VDC) between current carry parts and case Dielectric strength 1,000 VAC at 50/60 Hz for 1 min between current carry parts and case Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions Shock resistance 500 m/s2, 10 times each in X, Y and Z directions 1,000 m/s 2, 10 times each in X, Y and Z directions Standard and listings (See note 3.) IEC60529: IP67, Degree of protection EN60947-5-2: EMC Connection method -WP models: Pre-wired models (Standard length: 2 m) -M1 models: M12 4-pin connector models -M5 models: M8 3-pin connector models Weight (packaged) Pre-wired model Approx. 65 g Approx. 85 g M12 connector model M12 connector models: Approx. 20 g M8 connector models: Approx. 15 g Approx. 35 g Material Case Stainless steel or brass-nickel plated Brass-nickel plated Sensing surface PBT Cable PVC Clamping nut Brass-nickel plated
E2A Cylindrical Proximity Sensor 5 ■DC 3-wire Models Note 1. The response frequency is an average value. Measurement conditions are as follows: standard target, a distance of twice the standard target distance between targets, and a setting distance of half the sensing distance. 2. When using any model at an ambient temperature between -40°C and -25°C and a power voltage between 30 and 32 VDC, use a load current of 100 mA max. 3. For USA and CANADA : use class 2 circuit only. Size M18 M30 Type Shielded Non-shielded Shielded Non-shielded Non-shielded Item E2A-M18@S08-@@-B1 E2A-M18@S08-@@-B2 E2A-M18@S08-@@-C1 E2A-M18@S08-@@-C2 E2A-M18@N16-@@-B1 E2A-M18@N16-@@-B2 E2A-M18@N16-@@-C1 E2A-M18@N16-@@-C2 E2A-M30@S15-@@-B1 E2A-M30@S15-@@-B2 E2A-M30@S15-@@-C1 E2A-M30@S15-@@-C2 E2A-M30KN20-@@-B1 E2A-M30KN20-@@-B2 E2A-M30KN20-@@-C1 E2A-M30KN20-@@-C2 E2A-M30LN30-@@-B1 E2A-M30LN30-@@-B2 E2A-M30LN30-@@-C1 E2A-M30LN30-@@-C2 Sensing distance 8 mm±10% 16 mm±10% 15 mm±10% 20 mm ±10% 30 mm ±10% Setting distance 0 to 6.4 mm 0 to 12.8 mm 0 to 12 mm 0 to 16 mm 0 to 24 mm Differential travel 10% max. of sensing distance Target Ferrous metal (The sensing distance decreases with non-ferrous metal.) Standard target (mild steel ST37) 24×24×1 mm 48×48×1 mm 45×45 ×1 mm 60 ×60×1 mm 90× 90×1 mm Response frequency (See note 1.)
500 Hz 400 Hz 250 Hz 100 Hz 100 Hz
(operating voltage range) 12 to 24 VDC. Ripple (p-p): 10% max. (10 to 32 VDC) Current consumption (DC 3-wire) 10 mA max. Output type -B models: PNP open collector -C models: NPN open collector Control output Load current (See note 2.) 200 mA max. (32 VDC max.) Residual voltage 2 V max. (under load current of 200 mA with cable length of 2 m) Indicator Operation indicator (Yellow LED) Operation mode (with sensing object ap- proaching) -B1/-C1 models: NO -B2/-C2 models: NC For details, refer to the timing charts. Protection circuit Output reverse polarity protection, Power source circuit reverse polarity protection, Surge suppressor, Short-circuit protection Ambient air temperature Operating: −40°C to 70°C, Storage: −40°C to 85°C (with no icing or condensation) Temperature influence (See note 2.) ±10% max. of sensing distance at 23°C within temperature range of −25°C to 70°C ±15% max. of sensing distance at 23°C within temperature range of −40°C to 70°C Amb ient humidity Operating: 35% to 95%, Storage: 35% to 95% Voltage influence ±1% max. of sensing distance in rated voltage range ±15% Insulation resistance 50 MΩ min. (at 500 VDC) between current carry parts and case Dielectric strength 1,000 VAC at 50/60 Hz for 1 min between current carry parts and case Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions Shock resistance 1,000 m/s2, 10 times each in X, Y and Z directions Standard and listings (See note 3.) IEC60529: IP67, Degree of protection EN60947-5-2: EMC Connection method -WP models: Pre-wired models (Standard length: 2 m) -M1 models: M12 4-pin connector models -M5 models: M8 3-pin connector models Weight (pack- aged) Pre-wired model Approx. 160 g Approx. 280 g Approx. 280 g Approx. 370 g M12 connector model Approx. 70 g Approx. 200 g Approx. 200 g Approx. 260 g Material Case Brass-nickel plated Sensing surface PBT Cable PVC Clamping nut Brass-nickel plated
6 E2A Cylindrical Proximity Sensor
Operating Range (Typical) Influence of Sensing Object Size and Materials Shielded Models Distance Y (mm) X Y −30 −20 −10 0 10 20 30 E2A-M30@S15 Sensing distance X (mm) E2A-M18@S08 E2A-M12@S04 E2A-S08@S02/ E2A-M08@S02 Shielded Models X Y −50 −40 −30 −20 −10 0 10 20 30 40 50 Non-shielded Models Distance Y (mm) Sensing distance X (mm) E2A-M30LN30 E2A-M18@N16 E2A-M12@N08 E2A-S08@N04/ E2A-M08@N04 E2A-M30KN20 0 5 10 15 20 25 Side length of sensing object d (mm) Iron @d t = 1 mmX 0.5 1.0 1.5 2.0 2.5 5.0 4.0 3.0 2.0 1.0 @d t = 1 mmX 51 0 1 5 2 0 2 5 3 0 3 5 0 1.0 2.0 3.0 4.0 5.0 7.0 8.0 6.0 10 20 30 40 50 60 @d t = 1 mmX 10 20 30 40 50 60 70 80 @d t = 1 mmX Sensing distance X (mm) Stainless steel (SUS303) Aluminum Side length of sensing object d (mm) Brass Iron Sensing distance X (mm) Stainless steel (SUS303) Aluminum Copper Side length of sensing object d (mm) Brass Iron Sensing distance X (mm)Copper Stainless steel (SUS303) Aluminum E2A-S08@S02/M08@S02 E2A-M12@S04 E2A-M18@S08 E2A-M30@S15 Side length of sensing object d (mm) Sensing distance X (mm) Iron Stainless steel (SUS303) Brass Copper Brass Copper Aluminum
E2A Cylindrical Proximity Sensor 7 Non-shielded Models 5.0 4.0 3.0 2.0 1.0 0 10 20 30 40 50 @d t = 1 mmX @d t = 1 mmX 10 20 30 40 50 @d t = 1 mmX 20 40 60 80 20 40 60 80 100 @d t = 1 mmX E2A-S08@N04/M08@N04 Side length of sensing object d (mm) Sensing distance X (mm) Iron Brass Copper Stainless steel (SUS303) E2A-M12@N08 Side length of sensing object d (mm) Sensing distance X (mm) Iron Brass Aluminum Stainless steel (SUS303) Copper E2A-M18@N16 Side length of sensing object d (mm) Sensing distance X (mm) Iron Copper Brass Aluminum E2A-M30LN30 Side length of sensing object d (mm) Sensing distance X (mm) Iron Copper Brass Aluminum Stainless steel (SUS303) Stainless steel (SUS303) Aluminum Side length of sensing object d (mm) Sensing distance X (mm) 0 20 40 60 80 100 t = 1 mm X Copper Brass Iron Aluminum Stainless steel (SUS303) E2A-M30KN20
8 E2A Cylindrical Proximity Sensor
■PNP Output Operation mode Model Timing chart Output circuit NO E2A-@-@-B1 NC E2A-@-@-B2 Sensing object (%) 100 0 Rated sensing distance Sensing zoneNon-sensing zone Proximity Sensor ON OFF ON OFF Yellow indicator Control output 2 4 31 Load Brown Black (See note 1.) Blue 0 V Note 1: With M8 connector models, there is no output reverse polarity protection diode. M12 Connector Pin Arrangement (See note 2.) M8 Connector Pin Arrangement Note 2: Terminal 2 of the M12 connector is not used. Proximity Sensor main circuits (%) 100 0 Sensing object Rated sensing distance Sensing zoneNon-sensing zone Proximity Sensor ON OFF ON OFF Yellow indicator Control output 2 4 31 Load Brown Black (See note 1.) Blue 0 V Note 1: With M8 connector models, there is no output reverse polarity protection diode. M12 Connector Pin Arrangement (See note 2.) M8 Connector Pin Arrangement Note 2: Terminal 4 of the M12 connector is not used. Proximity Sensor main circuits (M8 connector: )
E2A Cylindrical Proximity Sensor 9 ■NPN Output Operation mode Model Timing chart Output circuit NO E2A-@-@-C1 NC E2A-@-@-C2 Sensing object (%) 100 0 Rated sensing distance Sensing zoneNon-sensing zone Proximity Sensor ON OFF ON OFF Yellow indicator Control output Load Brown Black(See note 1.) Blue 0 V Note 1: With M8 connector models, there is no output reverse polarity protection diode. M12 Connector Pin Arrangement (See note 2.) 2 4 M8 Connector Pin Arrangement Note 2: Terminal 2 of the M12 connector is not used. Proximity Sensor main circuits (%) 100 0 Sensing object Rated sensing distance Sensing zoneNon-sensing zone Proximity Sensor ON OFF ON OFF Yellow indicator Control output 2 4 31 Load Brown Black(See note 1.) Blue 0 V Note 1: With M8 connector models, there is no output reverse polarity protection diode. M12 Connector Pin Arrangement (See note 2.) M8 Connector Pin Arrangement Note 2: Terminal 4 of the M12 connector is not used. Proximity Sensor main circuits (M8 connector: )
10 E2A Cylindrical Proximity Sensor
Note:All units are in millimeters unless otherwise indicated. Pre-wired Models (Shielded) Pre-wired Models (Non-shielded) 3 5 M8×1 (See note 1.) E2A-S08KS02-WP-@@ 13 6 M8×1 6 dia. E2A-S08KN04-WP-@@ 50.3 M12×1 Two, clamping nuts E2A-M12KS04-WP-@@ E2A-M12KN08-WP-@@ 50.3 17 7 9.4 dia. M12×1 M18×1 41 0 59.5 E2A-M18KS08-WP-@@ E2A-M18KN16-WP-@@ 59.5 24 10 4 15.3 dia. M18×1 E2A-M30KS15-WP-@@ 5 10 64.5 M30×1.5 Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m 2. Operation indicator (yellow) Indicator (See note 2.) (See note 1.) (See note 1.) (See note 1.) (See note 1.) (See note 1.) (See note 1.) Two, clamping nuts Indicator (See note 2.) Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm 2; insulator diameter: 1.3 mm); standard length: 2 m 2. Operation indicator (yellow) Two, clamping nuts Indicator (See note 2.) Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m 2. Operation indicator (yellow) Two, clamping nuts Indicator (See note 2.) Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m 2. Operation indicator (yellow) Two, clamping nuts Indicator (See note 2.) Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m 2. Operation indicator (yellow) Two, clamping nuts Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm 2; insulator diameter: 1.3 mm); standard length: 2 m 2. Operation indicator (yellow) Indicator (See note 2.) Two, clamping nuts Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm 2; insulator diameter: 1.3 mm); standard length: 2 m 2. Operation indicator (yellow) Indicator (See note 2.) M30×1.5 (See note 1.) Two, clamping nuts Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m 2. Operation indicator (yellow) Indicator (See note 2.) 26.6 dia. 36 5 15 10 64.5 E2A-M30KN20-WP-@@
E2A Cylindrical Proximity Sensor 11 M12×1 72.3 M12×1 72.3 747 9.4 dia. M18×1 81.5 104 81.5 24 10 4 15.3 dia. M18×1 5 10 86.5 M30×1.5 M30×1.5 26.6 dia. 105 86.5 1536 (See note 1.) (See note 1.) (See note 1.) (See note 1.) (See note 1.) (See note 1.) E2A-M12LS04-WP-@@ E2A-M18LS08-WP-@@ E2A-M12LN08-WP-@@ E2A-M18LN16-WP-@@ E2A-M30LN30-WP-@@E2A-M30LS15-WP-@@ Two, clamping nuts Indicator (See note 2.) Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m 2. Operation indicator (yellow) Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m 2. Operation indicator (yellow) Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m 2. Operation indicator (yellow) Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m 2. Operation indicator (yellow) Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm 2; insulator diameter: 1.3 mm); standard length: 2 m 2. Operation indicator (yellow) Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm 2; insulator diameter: 1.3 mm); standard length: 2 m 2. Operation indicator (yellow) Two, clamping nuts Indicator (See note 2.) Two, clamping nuts Indicator (See note 2.) Two, clamping nuts Indicator (See note 2.) Two, clamping nuts Indicator (See note 2.) Two, clamping nuts Indicator (See note 2.) Mounting Hole Cutout Dimensions F External diameter of Proximity Sensor Dimension F (mm) M18 M30 M12 8.5 dia. +0.5 12.5 dia. +0.5 18.5 dia. +0.5 30.5 dia. +0.5 3 5 M8×1 (See note 1.) E2A-S08LS02-WP-@@ 13 6 M8×1 6 dia. E2A-S08LN04-WP-@@ (See note 1.) Two, clamping nuts Indicator (See note 2.) Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m 2. Operation indicator (yellow) Two, clamping nuts Indicator (See note 2.) Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m 2. Operation indicator (yellow)
12 E2A Cylindrical Proximity Sensor
M12 Connector Models (Shielded) M12 Connector Models (Non-shielded) E2A-S08KS02-M1-@@ E2A-M08KS02-M1-@@ E2A-M12KS04-M1-@@ E2A-M12KN08-M1-@@ 3 513 M8×1 M12×1 Note: Operation indicator (yellow LED, 4×90°) E2A-S08KN04-M1-@@ E2A-M08KN04-M1-@@ 6 dia. 3 5 613 M8×1 M12×1 E2A-M18KS08-M1-@@ E2A-M18KN16-M1-@@ M12×1 M12×1 9.4 dia. M12×1 M12×1 1024 4 M18×1 M12×1 24 104 15.3 dia. M18×1 M12×1 E2A-M30KS15-M1-@@ 36 10 M30×1.5 M12×1 Note: Operation indicator (yellow LED, 4×90°) Note: Operation indicator (yellow LED, 4×90°) Note: Operation indicator (yellow LED, 4×90°) Note: Operation indicator (yellow LED, 4×90°) Note: Operation indicator (yellow LED, 4×90°) Note: Operation indicator (yellow LED, 4×90°) Two, clamping nuts Indicator (See note.) Two, clamping nuts Indicator (See note.) Two, clamping nuts Indicator (See note.) Two, clamping nuts Indicator (See note.) Two, clamping nuts Indicator (See note.) Two, clamping nuts Indicator (See note.) Two, clamping nuts Indicator (See note.) 26.6 dia. M12×1 Note: Operation indicator (yellow LED, 4×90°) 5 1536 M30×1.5 Indicator (See note.) Two, clamping nuts E2A-M30KN20-M1-@@
E2A Cylindrical Proximity Sensor 13 M8 Connector Models (Shielded) M8 Connector Models (Non-shielded) M12×1 M12×1 9.4 dia. 717 M12×1 M12×1 1024 4 M18×1 M12×1 24 104 15.3 dia. M18×1 M12×1 36 10 M30×1.5 M12×1 10515 26.6 dia. M30×1.5 Note: Operation indicator (yellow LED, 4×90°) Note: Operation indicator (yellow LED, 4×90°) Note: Operation indicator (yellow LED, 4×90°) Note: Operation indicator (yellow LED, 4×90°) Note: Operation indicator (yellow LED, 4×90°) Note: Operation indicator (yellow LED, 4×90°) E2A-M12LS04-M1-@@ E2A-M18LS08-M1-@@ E2A-M30LS15-M1-@@ E2A-M12LN08-M1-@@ E2A-M18LN16-M1-@@ E2A-M30LN30-M1-@@ Two, clamping nuts Indicator (See note.) Two, clamping nuts Indicator (See note.) Two, clamping nuts Indicator (See note.) Two, clamping nuts Indicator (See note.) Two, clamping nuts Indicator (See note.) Two, clamping nuts Indicator (See note.) E2A-S08LS02-M1-@@ E2A-M08LS02-M1-@@ 3 513 M8×1 M12×1 Note: Operation indicator (yellow LED, 4×90°) E2A-S08LN04-M1-@@ E2A-M08LN04-M1-@@ 6 dia. 3 5 613 M8×1 M12×1 Note: Operation indicator (yellow LED, 4×90°) Two, clamping nuts Indicator (See note.) Indicator (See note.) M8×1 M8×1 E2A-S08KS02-M5-@@ E2A-S08KN04-M5-@@ 6 dia. 3613 5 M8×1 M8×1 Note: Operation indicator (yellow LED, 4×90°) Note: Operation indicator (yellow LED, 4×90°) 313 Two, clamping nuts Two, clamping nuts M8×1 M8×1 E2A-S08LS02-M5-@@ E2A-S08LN04-M5-@@ 6 dia. 3613 5 M8×1 M8×1 Note: Operation indicator (yellow LED, 4×90°) Note: Operation indicator (yellow LED, 4×90°) 313
14 E2A Cylindrical Proximity Sensor
■Safety Precautions Power Supply Do not impose an excessive voltage on the E2A, otherwise it may be damaged. Do not impose AC current (100 to 240 VAC) on any DC model, otherwise it may be damaged. Load Short-circuit Do not short-circuit the load, or the E2A may be damaged. The E2A’s short-circuit protection function will be valid if the polarity of the supply voltage imposed is correct and within the rated voltage range. Wiring Be sure to wire the E2A and load correctly, otherwise it may be dam- aged. Connection with No Load Be sure to insert loads when wiring. Make sure to connect a proper load to the E2A in operation, otherwise it may damage internal ele- ments. Do not expose the product to flammable or explo- sive gases. Do not disassemble, repair, or modify the product. ■Correct Use Designing Power Reset Time The Proximity Sensor is ready to operate within 100 ms after power is supplied. If power supplies are connected to the Proximity Sensor and load respectively, be sure to supply power to the Proximity Sen- sor before supplying power to the load. Effects of Surrounding Metal When mounting the E2A within a metal panel, ensure that the clear- ances given in the following table are maintained. (Unit: mm) Note 1. In the case of using the supplied nuts. If true flash mounting is necessary, apply a free zone of 1.5 mm. 2. In the case of using the supplied nuts. If true flush mounting is necessary, apply a free zone of 4 mm. Power OFF The Proximity Sensor may output a pulse signal when it is turned OFF . Therefore, it is recommended that the load be turned OFF before turning OFF the Proximity Sensor. Power Supply Transformer When using a DC power supply, make sure that the DC power sup- ply has an insulated transformer. Do not use a DC power supply with an auto-transformer. Mutual Interference When installing two or more Sensors face-to-face or side-by-side, ensure that the minimum distances given in the following table are maintained. (Unit: mm) Type Dimension M8 M12 M18 M30 Short barrel Long barrel Shielded l 000 (See note 1.) (See note 2.) m 4.5 12 24 45 d --- --- 27 45 D 001 . 5 4 n 1 21 82 7 4 5 Non- shielded l 12 15 22 30 40 m 8 20 48 70 90 d 2 44 07 0 9 0 1 2 0 D 1 21 52 2 3 0 4 0 n 2 44 07 0 9 0 1 2 0 l m n m D d dia. l Type Dimension M8 M12 M18 M30 Short barrel Long barrel Shielded A 20 30 60 110 B 1 52 03 57 0 Non- shielded A 80 120 200 300 300 B 60 100 120 200 300
E2A Cylindrical Proximity Sensor 15 Wiring High-tension Lines Wiring through Metal Conduit: If there is a power or high-tension line near the cable of the Proximity Sensor, wire the cable through an independent metal conduit to pre- vent against Proximity Sensor damage or malfunctioning. Cable Extension Standard cable length is less than 200 m. The tractive force is 50 N. Mounting The Proximity Sensor must not be subjected to excessive shock with a hammer when it is installed, otherwise the Proximity Sensor may be damaged or lose its water-resistivity. Do not tighten the nut with excessive force. A washer must be used with the nut. Maintenance and Inspection Periodically perform the following checks to ensure stable operation of the Proximity Sensor over a long period of time. 1. Check for mounting position, dislocation, looseness, or distortion of the Proximity Sensor and sensing objects. 2. Check for loose wiring and connections, improper contacts, and line breakage. 3. Check for attachment or accumulation of metal powder or dust. 4. Check for abnormal temperature conditions and other environ- mental conditions. 5. Check for proper lighting of indicators (for models with a set indi- cator.) Never disassemble or repair the Sensor. Environment Water Resistivity Do not use the Proximity Sensor underwater, outdoors, or in the rain. Operating Environment Be sure to use the Proximity Sensor within its operating ambient temperature range and do not use the Proximity Sensor outdoors so that its reliability and life expectancy can be maintained. Although the Proximity Sensor is water resistive, a cover to protect the Prox- imity Sensor from water or water-soluble machining oil is recom- mended so that its reliability and life expectancy can be maintained. Do not use the Proximity Sensor in an environment with chemical gas (e.g., strong alkaline or acid gasses including nitric, chromic, and concentrated sulfuric acid gases). Inrush Current A load that has a large inrush current (e.g., a lamp or motor) will damage the Proximity Sensor, in which case connect the load to the Proximity Sensor through a relay. Type Torque M8 Stainless steel type 9 N·m Brass type 4 N·m M12 30 N·m M18 70 N·m M30 180 N·m
Warranties, Limitations of Liability ■WARRANTY OMRON’s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON- INFRINGEMENT, MERCHANTABILITY , OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABL Y MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. ■ LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY , NEGLIGENCE, OR STRICT LIABILITY . In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY , REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON’S ANAL YSIS CONFIRMS THAT THE PRODUCTS WERE PROPERL Y HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations ■SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer’s application or use of the products. Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will be used. Know and observe all prohibitions of use applicable to this product. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERL Y RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Disclaimers ■CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. Consult with your OMRON representative at any time to confirm actual specifications of purchased product. ■DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. In the interest of product improvement, specifications are subject to change without notice. ALL DIMENSIONS SHOW N ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. D100-E1-01B OMRON Corporation Industrial Automation Company Sensing Devices Division H.Q. Industrial Sensors Division Shiokoji Horikawa, Shimogyo-ku, Kyoto, 600-8530 Japan
2008.7 OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2008 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. Cat. No. D100-E1-01B