E2R-A01 OMRON | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 4

Technical content

Compact Low Profile Inductive Proximity Sensor with 5 mm Sensing Distance ■ Non-contact sensing assures accurate detection regardless of target’s color or surface texture ■ Fast response time of 0.2 milliseconds (5 kHz) ■ High output current of 100 mA ■ Enclosure rating: IEC144 IP50 ■ Easy to mount package (6 mm high)

Ordering Information

■ Sensor ■ Connector Application Positioning a workpiece with sensor embedded in a conveyor system Sensing head Sensing dist ance Output configuration Part number Non-shielded 5 mm NPN, normally open E2R-A01 Appearance Cable length Part number 1 m E22-01

■ Ratings/Characteristics Note: 1. Refers to the distance from the detecting surface to the passing position of the detectable object which permits positive detection even when the sensing detecting surface is decreased due to temperature or voltage fluctuation. 2. The response frequencies for DC switching are average values measured on condition that the distance between each sensing object is twice as large as the size of the standard object and the sensing distance set is half of the maximum sensing distance. 3. Refers to a change in detecting distance when the ambient operating temperature changes within Omron’s specified range and is expressed as the rate of variation (in percentage) with the detecting distance at the rated voltage taken as 100%. 4. Refers to a change in detecting distance when the supply voltage changes within a permissible range and is expressed as the rate of variation (in percentage) with the detecting distance at the rated voltage taken as 100%. Engineering Data Supply voltage (operating voltage) 12 to 24 VDC +15%/-10%, ripple (p-p): 10% max. Current consumption 8 mA Detectable object Ferrous metals (refer to “ Engineering Data” for non-ferrous metals) Sensing distance 5 mm ±15% Setting distance (standard object) (see note 1) 0 to 3.4 mm (iron, 18 x 18 x 1 mm) Differential travel 10% of max. sensing distance Response frequency (see note 2) 5 kHz min. Operation Output transistor ON when sensing object Control output NPN open collector, 100 mA max. Indicators Operation indicator (red LED) Ambient temperature Operating: -10 to 55°C (14 to 131°F) with no freezing Ambient humidity Operating: 35% to 85% with no condensation Temperature influence (see note 3) ±20% max of sensing distance within a temperature range of -10 to 55°C (14 to 131°F) based on the sensing distance at a temperature of 23°C (73.4°F) Voltage influence (see note 4) ±2.5% max. of sensing distance within a range of ±10% of rated voltage Residual voltage 1.0 V max. (under load curr ent of 100 mA with cable length of 1 m) Insulation resistance 50 M Ω min. (at 500 VDC) between current carrying parts and case Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute between current carrying parts and case Vibration resistance Destruction: 10 to 55 Hz, 1.5 mm double amplitude for 2 hrs each in X,Y and Z directions Shock resistance Destruction: 500 m/s2 (approx. 50G) for 3 times each in X, Y and Z directions Enclosure rating IEC144 IP50 Weight Approx. 5.5 g Material Sensing Surface: PBT resin Rear cover: ABS resin

■ Output Circuit Diagram ■ Timing Chart Dimensions Unit: mm (inch) ■ E2R-A01 ■ E22-01

Effects of Surrounding Metal If there is any metal near the sensor, the metal may effect the per- formance of the E2R or the temperature of the metal may effect the sensing distance of the E2R. Make sure that the clearances given in the following illustrations are maintained for accurate sensing operation. Mutual Interference When installing two or more E2R units face to face or side by side, make sure that the minimum distances given in the following illustration is maintained. Handling and Connections The E2R incorporates a connector. Do not solder connector pins to lead wires. Use the E22-01 Connector or Molex connector (housing 010308033 and terminal 008700057) or Japan Molex connector (housing 5209-03 and terminal 5103). Do not impose external force on the terminal as shown in the fol- lowing illustration or else the terminal may be damaged. Do not connect or disconnect the connector with the E2R turned on as the E2R may be damaged. Power Supply When using a standard switching regulator with the E2R, ground the frame ground (FG) and ground (G) terminals of the switching regulator for stable operation. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, divide by 25.4 Cat. No. GC APMS-1 Printed in USA OMRON CANADA, INC.

885 Milner Avenue