E-1072-100 ETAL | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 4
Technical content
Features
l PLC controllable electronic switching amplifier (max. 3 A) with additional protective and control functions for DC 24 V loads (e.g. solenoids, magnetic brakes, electromagnetic clutches, monitoring and indicator lamps). l Overload and short-circuit proof double pole switching output with in-rush current and short-circuit limitation. l Electronic disconnection upon - an overload in the load circuit, - short-circuit in the load (load+/load-, load+/-US, and load-/+U S), followed by 2-pole isolation of the load circuit (via relay contacts). l Control input “In/Ctrl” with control current indication (YELLOW LED). l “O.K.” and availability indication (GREEN LED). l Short-circuit and overload indication (fault indication F and RED LED). l “Err1” group fault signalisation – all faults will be signalled: - wire breakage in the load circuit - earth fault at switching output - internal faults - overload or short circuit in the load circuit l “Err2” fault signalisation: - only overload or short circuit in the load circuit - reset required l Integral protection against reverse polarity and overvoltage for the control and load circuit.
Ordering information
Type No. E-1072 Solid State Remote Power Controller SSRPC 100 (trips only with overload or short circuit) Voltage rating of load DC 24 V Current rating 3 A E-1072 - 100 - DC 24 V - 3 A Technical data (Tambient = 25 °C, US = DC 24 V) Voltage rating UN DC 24 V Operating voltage US DC 19.2...36 V Current rating IN max. 3 A Current consumption I0 typically 24 mA (UContr = “0”) Power loss Pmax (IN=3 A) typically 3.5 W Residual ripple for all voltages max. 5 % (3 phase bridge) Reverse polarity protection US integral -> fault release, LEDs not lighting Caution: Ensure free travel of actuator button. Insulation voltage AC 500 V (control circuit, load circuit, fault indication “Err1” and “Err2”) Load Circuit Load output two pole switching output (minus and plus (term. 31-term. 32) switching), MOS transistors Max. load data DC 24 V/3 A (no derating over the entire temperature range!) Min. load data DC 24 V / 50 mA (wire break threshold 30 mA) Voltage drop at IN typically 0.9 V (Ri typically 300 mΩ) Switch times (ton / toff) typically 2 ms (resistive load) Overload disconnection approx 1.15 x IN (typically 3.45 A) Trip time (Iload= 2 x IN) typically 400 ms Short-circuit current IK typically 12 A current limitation Trip time (upon IK) typically 50 ms, 2-pole isolation of load circuit after approx. 200 ms –> RED LED indicates, fault indication F “Err1” and “Err2” Wire break monitoring with the load switched on or off; RED LED “Error” lighted, group fault signalisation “Err1” (UContr= “0”) wire break threshold Rload > 10 kΩ (UContr= “1”) minimum current Iload < 30 mA Supervision of load circuit with the load switched on, the load current is monitored via the two switching outputs GREEN LED indicates (OK signal), Iload > 30 mA Leakage current (UContr = “0”) typically 1 mA Free-wheeling circuitry integral Load current measurement no isolation of load circuit required as a (term. 33: +shunt/ 0.1 Ω/± 1 % measuring shunt is integral with term. 34: -shunt) the device. Measurement by voltmeter terminal 33 - terminal 34 (100 mV = 1 A) Isolation of load circuit 2-pole by relay contacts - by manual release of RED button - approx. 200 ms after electronic tripping due to overload or short circuit (“OFF”)
www.e-t-a.de Solid State Remote Power Controller E-1072-100 1646 Status matrixTechnical data (cont’d) Control circuit Control “In/Ctrl” internal low-level signal relay in control input (with integral free-wheeling diode) Control voltage U “0” : 0...2.4 V “1” : 18...32 V Control current I typically 5...10 mA Switching frequency fmax 10 Hz Control signal (UContr“1”) “In/Ctrl” YELLOW LED lights with I Contr flowing Protection reverse polarity protection (diode), overvoltage protection (varistor) Fault indication “Err1” group fault signalisation potential-free relay contact N/O, Fault indication “Err1” - wire breakage in the load circuit - load current < 30 mA - other faults (ground fault in load circuit or internal fault) - overload/short circuit (= “Err2”) - LED RED “Error” lighted - LED GREEN “O.K.” not lighted - relay contact “Err1” closed Signal delay typically 600 ms “Err2” fault indication potenial-free auxiliary contact, make contact N/O, Fault indication »Err2« - overload or short circuit in the load circuit - LED RED “Error” lighted - LED GREEN “O.K.” not lighted - relay contact “Err1” closed - auxiliary contact “Err2” closed - RED button “OFF” - reset required - load circuit isolated 2-pole - manual release “OFF” - reverse polarity of US (LEDs not indicating) Signal delay typically 200 ms General data Ambient Temperature 0...+50 °C (without condensation) Storage temperature -20 ...+70 °C Terminals COMBICON MSTBO 2.5/4 1x2.5 mm2 max. 16-pole Some are double terminals -> loop-through possibility (continuous load max. 6 A) Back-up protection circuit breaker for plus line for SSRPC (term. 41/42): depending on power supply capacity and number of loop-through arrangements, max. 12 A (= max. continuous load of the COMBICON terminals) Housing material PA 66-FR Mounting symmetric rail to EN 50022-35 Vibration 3 g, to IEC 60068-2-6 test Fc Degree of protection IP20 housing (IEC 529/DIN 40050) IP20 terminals EMC emitted interference EN 50081-1 interference suppression EN 61000-6-2 Mounting dimensions 22.5 x 99 x 122 mm (w x h x d) Mass approx. 130 g Typical time/current characteristics (TA = 25 °C ) trip time in ms 200 load current in A 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 3.5 4.5 5.5 6.5 7.5 8.5 9.5 10.5 11.5 current limitationtypical trip point: 1.15 x IN short-circuit disconnection in typically 50 ms Operating status Fault-free operation Short circuit/ overload in load circuit Wire break in load circuit Other faults Load output OFF 2-pol non- condutive ON 2-pole conductive OFF 2-pol non- condutive OFF 2-pol non- condutive ON 2-pole conduc- tive OFF 2-pol non- condutive Load circuit isolated 2 pole (via relay con- tacts) no no yes no no no Indication YELLOW LED »In/Ctrl« 0 1 1 0 1 0 GREEN LED »O.K.« 1 1 0 0 0 0 RED LED »Error« 0 0 1 1 1 1 relay contacts »Err1« open open closed closed closed closed auxiliary contacts »Err2« open open closed open open offen RED operating/ reset button ON ON OFF »OFF« ON ON ON Remark availability Load: >30 mA < 3 A RED button to be reset ground fault in load circuit or internal fault 1 = LED lights 0 = LED does not light Operating modes at: - reverse polarity: indication of fault “Err2”; LEDs not illuminated! - manual release “OFF” (RED button out): indication of fault “Err1” and “Err2”, additionally lighted LED RED “Error”. - with U S = 0 V: not fault indication “Err1”.
www.e-t-a.de Solid State Remote Power Controller E-1072-100 1646 Solid State Remote Power Controller E-1072-100 Dimensions Basic circuit diagram Terminal selection Connection diagram symmetrical rail to DIN 50022-35114 22.5 3.90 .315 4.49 .886 1072 -100- DC 24V/3A 21 22 23 24 11 12 13 14 31 32 33 34 41 42 43 44 In/Ctrl O.K. Error OFF Shown in OFF condition with no load (US= 0 V) and red button tripped (“OFF”) yellow -US 24232233 3234 31 43 44 41 42 43 control electronicsro OL/SC 0.1Ω shunt load-+ 11 13 14 +US +UContr -UContrred green Erroror In/Ctrl “In/Ctrl” - LED yellow “O.K.” - LED green “Error” - LED red “OFF” - red button “Err1” - relay contact “Err2” - auxiliary contact 21 22 23 24 11 12 13 14 31 32 33 34 41 42 43 44 Top side LEVEL 2 (fault indication) LEVEL 1 (control input) LEVEL 3 (load circuit) LEVEL 4 (voltage supply) Cable side (bottom)All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved. Product markings may not be exactly as the ordering codes. Errors and omissions excepted. This is a metric design and millimeter dimensions take precedence ( mm ) inch Level Terminal Remark 1 11 +UContr (control voltage plus) DC 18...32 V 1 13 / 14 -UContr (control voltage minus) 1 12 not use 2 21 “Err2” fault indication OL/SC signal contact NO 2 22 / 23 joint terminal “Err1”, “Err2” C 2 24 “Err1” group fault indication relay contact NO) 3 31 Load (+) DC 24 V/max.
3 A3 32 Load (-)
load current measurement by voltmeter (shunt 0.1 Ω/± 1 % integral with device, 100 mV = 1 A) term. 33: shunt+ / term. 34: shunt- 4 41 / 42 +U S (operating voltage plus) DC 19.2...36 V 4 43 / 44 -US (operating voltage minus)