6W DC/DC CONVERTER, DIP-Package, High Isolation DS_DU06S/D_07192012 E-mail: DCDC@delta.com.tw http://www.delta.com.tw/dcdc

FEATURES

Š Efficiency up to 80% Š Reinforced Insulation rated for 300VAC Working Voltage Š Isolation Voltage 4,000VACrms Š UL/EN60601-1&EN60950-1 Safety Approval Š Overload Protection Š Fully regulated Output Voltage Š Low Leakage Current Š Operating Temperature Range –40°C to +75 °C Š Complies with EN55022, class A Š 3 Years Product Warranty The.DU06S/D series are miniature, DIP Package, isolated 6W DC/DC converters with 4,000VACrms isolation. It offers short circuit protection and allows a wide operating temperature range of –40°C to +75°C. These isolated DC/DC converters are the lat est offering from a world leader in power systems technology and manufacturing ― Delta Electronics, Inc. With creative design technology and optimization of component placement, these converters possess outstanding electrical and thermal performance, as well as extremely high reliability under highly stressful operating conditions.. Model List Output Current Input Current Efficiency (typ.) Input Voltage (Range) Output Voltage Max. Min. @Max. Load @No Load Reflected Ripple Current Max. capacitive Load @Max. Load Model Number VDC VDC mA mA mA(typ.) mA(typ.) mA (typ.) uF % DU06S1205A 5 1000 200 570 1000 75 DU06S1212A 12 500 100 641 470 78 DU06D1212A ±12 ±250 ±50 641 220* 78 DU06D1215A (9 ~ 18) ±15 ±200 ±40 641 30 60 220* 78 DU06S2405A 5 1000 200 278 1000 77 DU06S2412A 12 500 100 313 470 80 DU06D2412A ±12 ±250 ±50 313 220* 80 DU06D2415A (18 ~ 36) ±15 ±200 ±40 313 20 30 220* 80 DU06S4805A 5 1000 200 139 1000 77 DU06S4812A 12 500 100 156 470 80 DU06D4812A ±12 ±250 ±50 156 220* 80 DU06D4815A (36 ~ 75) ±15 ±200 ±40 156 10 15 220* 80 * For each output Input Characteristics Parameter Model Min. Typ. Max. Unit 12V Input Models -0.7 --- 25 24V Input Models -0.7 --- 50 Input Surge Voltage (1 sec. max.) 48V Input Models -0.7 --- 100 12V Input Models 7 8 9 24V Input Models 13 15 18 Start-Up Voltage 48V Input Models 30 33 36 12V Input Models --- --- 8.5 24V Input Models --- --- 16 Under Voltage Shutdown 48V Input Models --- --- 34 VDC Short Circuit Input Power --- --- 3000 mW Internal Power Dissipation --- --- 2500 mW Conducted EMI All Models Compliance to EN55022,class A and FCC part 15,class A

DS_DU06S/D_07192012 E-mail: DCDC@delta.com.tw http://www.delta.com.tw/dcdc P2 Output Characteristics Parameter Conditions Min. Typ. Max. Unit Output Voltage Accuracy --- ±0.5 ±1.0 % Output Voltage Balance Dual Output, Balanced Loads --- ±0.5 ±2.0 % Line Regulation Vin=Min. to Max. --- ±0.3 ±0.5 % Load Regulation Io=25% to 100% --- ±0.5 ±1.0 % 5V Output Models --- 75 100 mV P-P Ripple & Noise (20MHz) Other Output Models --- 100 150 mV P-P Ripple & Noise (20MHz) Over Line, Load & Temp. --- --- 180 mV P-P Ripple & Noise (20MHz) --- --- 25 mV rms Transient Recovery Time --- 300 500 uS Transient Response Deviation 25% Load Step Change --- ±3 ±6 % Temperature Coefficient --- ±0.02 ±0.05 %/ ℃ Over Load Protection Foldback 120 150 --- % Short Circuit Protection Continuous Isolation, Safety Standards Parameter Conditions Min. Typ. Max. Unit I/O Isolation Voltage (rated) 60 Seconds 4000 --- --- VACrms I/O Isolation Test Voltage Flash tested for 1 Second 6000 --- --- V PK Leakage Current 240VAC, 60Hz --- --- 2 uA I/O Isolation Resistance 500 VDC 10 --- --- G Ω I/O Isolation Capacitance 100KHz, 1V --- 7 13 pF cUL/UL60950-1, CSA C22.2 No. 60950-1-03 UL60601-1,CSA C22.2 No.601-1, Safety Standards IEC/EN 60950-1, IEC/EN 60601-1 IEC60950-1 CB report, cUL/UL 60950-1 certificate Safety Approvals UL60601-1 UL certificate General Characteristics Parameter Conditions Min. Typ. Max. Unit Switching Frequency --- 150 --- KHz MTBF(calculated) MIL-HDBK-217F@25℃, Ground Benign 700,000 --- --- Hours Recommended Input Fuse 12V Input Models 24V Input Models 48V Input Models 1200mA Slow-Blow Type 600mA Slow-Blow Type 300mA Slow-Blow Type Environmental Characteristics Parameter Conditions Min. Max. Unit Operating Temperature Range (with Derating) Ambient -40 +75 ℃ Case Temperature --- +95 ℃ Storage Temperature Range -50 +125 ℃ Humidity (non condensing) --- 95 % rel. H Cooling Free-Air convection Lead Temperature (1.5mm from case for 10Sec.) --- 260 ℃

DS_DU06S/D_07192012 E-mail: DCDC@delta.com.tw http://www.delta.com.tw/dcdc P3 Power Derating Curve Output Power (%) Notes 1 Specifications typical at Ta=+25 ℃, resistive load, nominal input voltage and rated output current unless otherwise noted. 2 Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%. 3 Ripple & Noise measurement bandwidth is 0-20 MHz. 4 These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will not damage these modules; however, they may not meet all specifications listed. 5 All DC/DC converters should be externally fused at the front end for protection. 6 Specifications subject to change without notice. Mechancial Drawing Mechanical Dimensions Pin Connections Pin Single Output Dual Output 1 +Vin +Vin

11 No Pin Common

15 No Pin +Vout

►All dimensions in mm (inches) ►Tolerance: X.X±0.25 (X.XX±0.01) X.XX±0.13 ( X.XXX±0.005) ►Pin diameter ⇔ 0.6 ±0.05 (0.024±0.002) Physical Outline Case Material : Non-Conductive Black Plastic (flammability to UL 94V-0 rated) Weight : 18g Bottom View 131524 20.32 [0.80] 31.8 [1.25] 15.22 [0.60] 20.3 [0.80] 12.0 [0.47] 0.60 [0.024] 5.08 [0.20] 3.8 [0.15] 2.54 [0.10] 0.5 [0.02] 2.0 [0.08] 2.54 [0.10]

DS_DU06S/D_07192012 E-mail: DCDC@delta.com.tw http://www.delta.com.tw/dcdc P4 Part Numbering System D U 06 S 12 05 A Form factor Family series Watt Number of Outputs Input Voltage Output Voltage Option Code D-DIP A~Z 01:1W S - Single 03:3.3V 03:3.3V A - Std. Functions P-SIP 02:2W D- Dual 05: 5V 05: 5V S-SMD 03:3W 12:12V 12:12V 04:4W 24: 24V 15: 15V 06:6W 48:48V 24: 24V WARRANTY Delta offers a three(3) years limited warranty. Complete warranty information is listed on our web site or is available upon request from Delta. Information furnished by Delta is believed to be accurate and reliable. However, no responsibility is assumed by Delta for its use, nor for any infringements of patents or other rights of third parties, which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Delta. Delta reserves the right to revise these specifications at any time, without notice.