www.pairuigroup.com Page: 1 / 4 Date: 01/07/2013 DC-DC Converter DIP-Package DTV-40 SERIES, 40WATT,2:1 INPUT RANGE FEATURES: 3 year warranty Six-side shielded metal case Low ripple and noise Over current and short circuit protection Remote on/off Adjustable output voltage Model Input voltage (Vdc) Output voltage (Vdc) Output current (A) Efficiency Typ. DTV40-1211 12(9~18) 5 8 80% DTV40-1212 12 3.3 85% DTV40-1213 15 2.67 85% DTV40-1214 24 1.66 85% DTV40-2411 24(18~36) 5 8 80% DTV40-2412 12 3.3 85% DTV40-2413 15 2.67 85% DTV40-2414 24 1.66 85% DTV40-4811 48(36~72) 5 8 80% DTV40-4812 12 3.3 85% DTV40-4813 15 2.67 85% DTV40-4814 24 1.66 85% DTV40-11011 110(72~144) 5 8 80% DTV40-11012 12 3.3 85% DTV40-11013 15 2.67 85% DTV40-11014 24 1.66 85% Notes: 1. Other input and output models may available on request; 2. Above models are default to metal case and with heatsink, plus “R” in the suffix. ELECTRICAL Input voltage range 12V 9-18Vdc 24V 18-36Vdc 48V 36-72Vdc 110V 72-144Vdc Remote control (Low level remote) High level or vacant Low level or connect ground Turn on Turn off Output voltage accuracy --- ±1 Output voltage adjustable --- ±10% max. Line regulation Nominal Load, full voltage ±0.2%

www.pairuigroup.com Page: 2 / 4 Date: 01/07/2013 DC-DC Converter DIP-Package DTV-40 SERIES, 40WATT,2:1 INPUT RANGE ELECTRICAL Load regulation 20% ~ 100% rated load ±0.5% Dynamic response (transient/recovery time) 5%-50%-75% load capability ∆Vo1/∆t: ±4.0%/500μs Ripple and noise 20MHz BM, full load Vo ≤ 5.0V, ≤ 50mVp-p Vo≥ 48V, ≤ 180mVp-p Other, ≤ 100mVp-p Isolation voltage (<2mA/min) Input to output 1500Vdc Input to case 500Vdc Switching frequency 300KHz 300KHz max. Turn-on delay time --- ≤ 200ms Operating temperature range Free air -25℃ to +55℃ Storage temperature range --- -45℃ to +105℃ Input under voltage protection When input voltage is lower than the low input voltage Auto-recovery Over current protection --- Auto-recovery Short circuit protection --- Continuous auto-recovery Relative humidity --- 10%-90% max. Weight --- 223g MTBF Bellcore TR-332, 25 ℃ 2x105Hrs Notes: Unless otherwise specified, all the parameters of the test conditions are as follows: ambient temperature 25℃ , the nominal input voltage, pure resistive nominal load. MECHANICAL CONNECTION PIN # SINGLE 1 -Vin

2 REM

3 CASE

7 TRIM

9 GND

Note: * Unit is mm(inch).

www.pairuigroup.com Page: 3 / 4 Date: 01/07/2013 DC-DC Converter DIP-Package DTV-40 SERIES, 40WATT,2:1 INPUT RANGE MECHANICAL LAYOUT TEMPERATURE PROFILE

www.pairuigroup.com Page: 4 / 4 Date: 01/07/2013 DC-DC Converter DIP-Package DTV-40 SERIES, 40WATT,2:1 INPUT RANGE NOTES RECOMMENDEDTEST AND APPLICATIONCIRCUIT 1. TVS&FUSE be helpful with over voltage protection and inrush limiting. Recommended FUSE better be 1.5~2times of the rated current . 2. The input filter capacitor C6 could select the aluminum electrolytic capacitors or tantalum capacitors, and the withstand voltage should be greater than the highest input voltage. Recommended capacitor should be between 22μF~100μF. 3. C1,C2 for the input filter capacitor,0.1~1μF high-frequency ceramics capacitor or chip capacitor are recommended. The withstand voltage of output filter C5, C7 should be greater than the highest output voltage. Recommended capacitor of C7 better within 100μF and C5 connected with thechip to reduce the input voltage peak, recommended 0.1~1μF high-frequency ceramics capacitor or chip capacitor.