DTL22A MURATA | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 4
Technical content
Features
Applications
0-10V input/control voltage 0-20A output/load current 2.5-50V output compliance voltage 0-100W output/load power 10MΩ output impedance 500Vdc isolation ±1% accuracy under all conditions 200µsec full-scale step response 2" x 2", shielded metal package Operate in parallel for higher power Power-supply test and characterization Static/dynamic power-supply burn-in Power-resistor substitution Real-time load simulation Capacitor discharge testing
DTL22A Model Voltage-Controlled
20 Amp 100 Watt, Electronic Loads
MDC_DTL22A.B01 Page 2 of 4 Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000www.murata-ps.com Pin Function P51 Pin Function P51 1 +5 Volt Supply 7 Control Voltage In (–) 2 +5 Volt Return 8 –Load
3 Fault 9 –Load
4 No Pin 10 +Load
5 Control Voltage In (+) 11 +Load
6 No Pin
Performance Specifi cations and Ordering Guide PART NUMBER STRUCTURE MECHANICAL SPECIFICATIONS Input Output DTL 22 DATEL Electronic Load Voltage Range: 22 = 2.5 to 50V A A-Series High Reliability TEMPERATURE DERATING I/O Connections Contact DATEL for Heat Sink information. The horizontal axis of the above chart references the temperature of the DTL22A’s aluminum baseplate. The device can continually dissipate up to 100 Watts if the baseplate is maintained at or below +50°C. At +25°C ambient temperature, with no heat sink or supplemental air fl ow, the DTL22A can reliably dissipate a continuous 10 Watts. Case C24 Control Compliance Voltage Impedance Current Resolution Voltage Power Package Model (Volts) (Minimum) (Amps) (mA) ➁ (Volts) ➂ (Watts) (Case, Pinout) DTL22A 0 to +10 10M Ω 0-20 5 2.5-50 0-100 C24, P51 ➀ Typical at TA = +25°C with nominal +5V supply voltage, unless noted. ➁ Listed resolution (5mA) is for a typical application in which the DTL22A is controlled by a voltage generated by a 12-bit D/A converter with a 0-10V output range. One LSB (least signifi cant bit) of the D/A corresponds to 0.0244% (1/4096) of full scale (20 Amps), which equals approximately 5mA. ➂ For proper operation, the unit's output/load voltage must remain within this range. Voltages greater than the listed maximum can damage the device. Voltages less than the minimum provide insuffi cient bias for the output stage and will result in unpredictable or no operation. See Output Compliance Voltage and the Fault Line for details. Output Power/Load (Watts) Baseplate Temperature (°C) 100 01 0 2 03 04 05 06 07 08 09 0 1 0 0
DTL22A Model Voltage-Controlled MDC_DTL22A.B01 Page 3 of 4 Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000www.murata-ps.com Input Control Voltage 0-10 Volts Impedance 10M Ω, minimum Output Transfer Function IOUT (Amps) = 2VIN (Volts) Current: Range 0-20 Amps Resolution ➀ 0.025%FS (5mA) Offset Error ➁ ±5mA, maximum Gain Error ±0.25%, maximum Absolute Accuracy ➂ ±1%, maximum Voltage ➃ 2.5-50 Volts Power ➄ 0-100 Watts Impedance 10M Ω, minimum Isolation Voltage: Analog Input to ±Load 500Vdc, minimum +5V Power to Input or ±Load 500Vdc, minimum Any Pin to Case 500Vdc, minimum Isolation Resistance 100M Ω, minimum Fault Logic Levels: Logic "1" (@ 150µA) +3.5 Volts, minimum Logic "0" (@ 1.6mA) +0.4 Volts, maximum Dynamic Performance Output Slew Rate 0.4A/µsec, minimum Output Settling Time ➅ 200µsec Dynamic Loading: ➅ 10mA to 20A 5kHz 0 to 20A 1kHz Power Requirements Power Supply Range (+VCC, Pin 1) +4.75-5.25 Volts (+5V nominal) Power Supply Current 110mA typ., 150mA max. Environmental Operating Temperature ➆ –25 to +85°C Storage Temperature –40 to +85°C Humidity (Non-condensing) to 95% Altitude Above Sea Level 10,000 feet Physical Dimensions 2" x 2" x 0.5" (51 x 51 x 12.7mm) Shielding 6-sided Case Material Tin-plated steel shell with aluminum baseplate Pin Material Brass, solder coated Mounting Holes Through-hole spacers, #4-40 clearance Weight 1.9 ounces (54 grams) ➀ Listed resolution (5mA) is for a typical application in which the DTL22A is controlled by a voltage generated by a 12-bit D/A converter with a 0-10V output range. One LSB (least signifi cant bit) of the D/A corresponds to 0.0244% (1/4096) of full scale (20 Amps), which equals approximately 5mA. ➁ Offset error is defi ned as the current sunk/sourced by the DTL22A’s output, under any output-voltage conditions, when the applied control voltage is 0 Volts. ➂ Applies over all ranges/combinations of specifi ed output current, load voltage, output power, operating temperature and V CC. ➃ For proper operation, the DTL22A's output voltage must remain within the range listed. Voltages greater than the listed maximum can damage the device. Voltages less than the listed minimum provide insuffi cient bias for the output stage and will result in unpredictable or no operation. See Ouput Compliance Voltage and the Fault Line for details. ➄ The DTL22A can achieve its maximum output/load power only when its baseplate temperature is properly maintained. See Temperature Derating. ➅ Specifi ed for the full-scale step from 10mA to 20 Amps settling to ±1% (±200mA) of fi nal value. A minimal loading of 10mA is recommended to achieve the fastest dynamic response. ➆ Baseplate temperature. See Note 5 and Temperature Derating. Supply Voltage (+VCC, Pin 1) –0.5 to +5.5 Volts Input Voltage (Pin 4) –0.5 to 15 Volts Output Reverse-Polarity Protection No protection Output Overvoltage Protection No protection Output Undervoltage Protection Y es (See Fault Line) Case Temperature +85°C Storage Temperature (Ambient) –40 to +85°C Lead Temperature (Soldering, 10 sec.) +300°C Absolute Maximum Ratings These are stress ratings. Exposure of devices to any of these conditions may adversely affect long-term reliability. Proper operation under conditions other than those listed in the Performance/Functional Specifi cations Table is not implied. TECHNICAL NOTES Overview The DTL22A is an analog programmable (0 to +10V control) current sink. It’s output/load current range is 0 to 20 Amps over a compliance voltage range of 2.5 to 50 Volts and an output/load power range of 0 to 100 Watts. The device’s transfer function is as follows: Iout (Amps) = 2V IN (Volts) Examples: Control VIN = 1 Volt, IOUT = 2 Amps Control V IN = 10 Volts, IOUT = 20 Amps In a typical power-supply test or burn-in application, the "positive" output and "return" pins of the device under test (DUT) are connected to the DTL22A’s +Load (pins 10 and 11) and –Load (pins 8 and 9) outputs. Performance/Functional Specifi cations Typical @ TA = +25°C with nominal +5V supply voltage, unless noted.
notice. © 2009 Murata Power Solutions, Inc. Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfi eld, MA 02048-1151 U.S.A. becoming disabled, the Fault line activates. 50V, and operation above 50V can damage the device. output be allowed to experience a polarity reversal. Figure 2. An "Offset Supply" Enables voltage across the load), then R = VLOAD /I = VLOAD / (2 × VLOAD ) = 0.5 Ohms. Consequently, the load looks like a 0.5 Ohm resistor. resistive divider across the load, then R = VLOAD / (2 × k × VLOAD) = 0.5/k.