DSSIU-4-1U-1 DANISENSE | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 6

Technical content

Features

  • Compact 19” rack mount 1U height
  • Current transducers’ output signals available via 4mm banana plugs (Only current output)
  • Front LEDs indication of normal operation for each transducer and power LED for DSSIU-4-1U
  • Universal autorange (100-240V AC 50/60Hz) AC input voltage or 120–370V DC input voltage.

page 2 - 2022- 11-24 Precision – Innovation www.danisense.com Specifications Parameter Symbol Unit Min Typ. Max Comment Mains input AC input voltage VAC Vrm s 85 264 Autoranging AC nominal current IAC Irm s 1.6A @ 115V 0.7A @ 230V Full scale operation with 4 DS2000 and 3000A primary Frequency f Hz 47 63 Autoranging Transducer output port Supply voltage Ucc ±14.7 ±15.75 x4 channels Ripple mVrm s 15 Environment and Mechanical Ambient operating temperature range Ta ºC 5 40 Storage temperature range ºC -20 85 Relative humidity % 20 80 Mass Kg 4.6 Size (W x H x D) mm 483 x 44 x 271 Channel configuration Each channel does have 3 connectors.

  • Transducer (DSUB9) for connection to the transducer
  • RED + (4mm Banana) is positive output from the measured current
  • BLACK - (4mm Banana) is negative output from the measured current Current output configuration The DSSIU-4-1U will send the measured current to the RED and BLACK 4mm banana jacks. RED being connected to pin 6 on the transducer. BLACK being connected to pin 1 on the transducer.

page 3 - 2022- 11-24 Precision – Innovation www.danisense.com Environmental, safety and mechanical specifications Parameter Unit Min Typ Max Comment Altitude m 2000 Usage Designed for indoor use Polution Degree 2 Ambient operating temper- ature range Storage temperature range °C 0 60 Relative humidity % 20 80 Non-condensing Mass kg 5.0 Connections DSUB9 female for transducer connection 4mm banana (red and black) jacks for output of measured current from transducers 4mm banana (Yellow) jacks for connection of calibration current to transducer DSUB15 female for status information IEC inlet for mains connection Standards IEC61326-1 EMC IEC61010-1:2010 3rd Edition External devices Only connect Danisense transducers to the DSSIU-4-1U Cleaning The unit should only be cleaned with a damp cloth. No detergent or chemicals should be used.

page 4 - 2022- 11-24 Precision – Innovation www.danisense.com Mechanical Dimensions

page 5 - 2022- 11-24 Precision – Innovation www.danisense.com User Guide Intended use: The DSSIU-4-1U is designed to work with Danisense transducers with DSUB9 connection powered by +/-15V. Instruction for use: 1. Do not power up the device before all cables are connected. 2. Only use cable provided by Danisense to ensure correct wiring and dimension of cable. 3. Ensure that it is easy to unplug the mains cord in case of system problems. 4. Place the primary conductor through the apperture of the transducer(s) 5. If the DSSIU-4-1U is intended for desk use, mount the rubber feet which are part of the package. 6. If the DSSIU-4-1U is intended for Rack mounting, use the screw kit for mounting and do not mount the rubber feet.

  • It is mandatory to support the unit when rack mounted, either on the sides or backside. 7. Connect a Danisense DSUB cable between DSSIU-4-1U and each sensor 8. Connect a low impedance amperemeter, measuring resistor or power analyzer on the secondary output (4mm red and black connectors) 9. Ensure that no calibration connectors are attached when measuring primary current. Always avoid to create a calibration short circuit, between + and — calibration connection. 10. There is a risk of electrical shock if an uninsulated busbar with high voltages is touching the metal enclosure of the transducer. Please ensure before powering up the system that no primary busbar can touch the metal enclosure. 11.When all connection are secured - connect mains power with the mains cable deli vered. If other cables are used ensure that the cable has sufficint rating for operation. 12.Apply primary current Safety Instructions: DO NOT TRY TO DISASSEMBLE THE UNIT. If the green transducer diode is not operating when the system is powered up, disconnect power and contac t Dan- isense for further instruction. If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.. Indications: When mains is applied the left light diode on the front under the power symbol will light green. For each sensor channel connected a green light diode will light on the front if the connection is correct and the sensor is operating within normal range.

page 6 - 2022- 11-24 Precision – Innovation www.danisense.com Declaration of Conformity Danisense A/S Malervej 10 DK-2630 Taastrup Denmark Declares that under our sole responsibility that this product is in conformity with the provisions of the following EC Directives, including all amendments, and with national legislation implementing these directives: Directive 2014/30/EU Directive 2014/35/EU And that the following harmonized standards have been applied EN 61010-1 (Third Edition):2010, EN 61010-1:2010/A1:2019 EN 61010-2-030:2021/A11:2021 EN 61326-1:2013 All DANISENSE products are manufactured in accordance with RoHS directive 2011/65/EU. Annex II of the RoHS directive was amended by directive 2015/863 in force since 2015, expanding the list of 6 restricted substances (Lead, Hexavalent Chromium, PBB, PBDE and Cadmium) Danisense follows the provision in EN 63000:2018 Place Date Taastrup, Denmark Henrik Elbæk 2022-07-14