ELECTRICAL CHARACTERISTICS

T =25°C unless otherwise specified C =25°C unless otherwise specified Symbol Parameter Test Conditions Values Unit V Maximum D.C. Reverse Voltage R 200 V V Maximum Repetitive Reverse Voltage RRM 200 V I Average Forward Current F(AV) T C 30 =100°C, Per Diode A T C 60 =100°C, Per Package A I RMS Forward Current F(RMS) T C 53 =100°C, Per Diode A I Non-Repetitive Surge Forward Current FSM T J 300 =45°C, t=10ms, 50Hz, Sine A P Power Dissipation D 156 W T Junction Temperature J -40 to +150 °C T Storage Temperature Range STG -40 to +150 °C Torque Module-to-Sink Recommended(M3) 1.1 N·m R Thermal Resistance θJC Junction-to-Case 0.8 °C /W Weight 6.0 g Symbol Parameter Test Conditions Min. Typ. Max. Unit I Reverse Leakage Current RM V R -- =200V -- 25 µA V R =200V, T J V Forward Voltage F I F -- =30A 0.86 1.1 V I F =30A, T J t Reverse Recovery Time rr I F =1A, V R =30V, di F -- /dt=-200A/μs 22 -- ns t Reverse Recovery Time rr V R =100V, I F =30A di F /dt=-200A/μs, T J =25°C 26 -- ns I Max. Reverse Recovery Current RRM -- 2.3 -- A t Reverse Recovery Time rr V R =100V, I F =30A di F /dt=-200A/μs, T J =125°C 40 -- ns I Max. Reverse Recovery Current RRM -- 4.1 -- A TO-247AD DSEK60-02A Pb Free Plating Product DSEK60-02A

60.0 Ampere,200 Volt Common Cathode Fast Recovery Epitaxial Diode

Cathode(Bottom Side Metal Heatsink) Cathode Anode Base Backside

  • Ultrafast Recovery Time
  • Soft Recovery Characteristics
  • Low Recovery Loss
  • Low Forward Voltage
  • High Surge Current Capability
  • Low Leakage Current APPLICATION GENERAL DESCRIPTION Freewheeling, Snubber, Clamp Inversion Welder PFC Plating Power Supply Ultrasonic Cleaner and Welder Converter & Chopper UPS PRODUCT FEATURE DSEK60-02A using the lastest FRED FAB process(planar passivation chip) with ultrafast and soft recovery characteristics. © 2006 Thinki Semiconductor Co.,Ltd. http://www.thinkisemi.com/ Page 1/3Rev.05 Anode

I F (A) V F (V) Fig1. Forward Voltage Drop vs Forward Current T J =125°C T J =25°C 0 0.2 0.4 0.8 1.0 1.2 di F /dt(A/μs) Fig2. Reverse Recovery Time vs di F /dt 1000 800 600 400 200 0 0 t rr (ns) 100 V R =100V T J =125°C I F =60A I F =15A I F =30A I RRM (A) di F /dt(A/μs) Fig3. Reverse Recovery Current vs di F /dt 0 200 400 600 800 1000 di F /dt(A/μs) Fig4. Reverse Recovery Charge vs di F /dt 1000 800 600 400 200 0 0 Q rr (nc) 100 150 200 250 V R =100V T J =125°C I F =60A I F =15A I F =30A V R =100V T J =125°C I F =60A I F =30A I F =15A K f Duty 0.5 0.2 0.1 0.05 Single Pulse 0.2 0.4 1.2 0.6 Z thJC (K/W) 0.8 I RRM Q rr t rr T J (°C) Fig5. Dynamic Parameters vs Junction Temperature 0 25 50 100 150 1 10 Rectangular Pulse Duration (seconds) Fig6. Transient Thermal Impedance 75 125 0.6 © 2006 Thinki Semiconductor Co.,Ltd. http://www.thinkisemi.com/ Page 2/3Rev.05 DSEK60-02A

Fig7. Diode Reverse Recovery Test Circuit and Waveform I F dI F /dt t rr I RRM Q rr 0.25 I RRM 0.9 I RRM © 2006 Thinki Semiconductor Co.,Ltd. http://www.thinkisemi.com/ Page 3/3Rev.05 DSEK60-02A Dimensions in Millimeters Fig8. Package Outline