DS93 BRIDGELUX | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 39

Technical content

Datasheet sections

29 Array

Vero® Series is a revolutionary advancement in chip on board (COB) light source technology and innovation. Vero LED light sources simplify luminaire design and manufacturing processes Vero Chip on Board (COB) LED arrays are available in four LES configurations, engineered to enable new degrees of flexibility and reliability over a broad range of electrical currents. Vero arrays deliver increased lumen density to enable improved beam control and precision lighting with 2 and 3 SDCM color control standard for clean and consistent uniform lighting. Vero products include an onboard connector port that enables a solder-free electrical interconnect, and simple mounting features for plug-and-play installation. Bridgelux Décor Series™ is our state-of-the-art color line designed specifically for premium applications, producing unmatched LED light quality with brilliant color-rendering options and pleasing lighting palettes. Bridgelux Décor Series color points are available on Vero® SE Series, Vero® Series, V Series™ and V Series™ HD. Décor Series™ Class A is based on human response testing, providing color points with a combined GAI and CRI metric. Décor Series™ Ultra products provide a high CRI of 97 and typical R9 value of 98, which emphasizes the reds and color tones to which the human eye is most receptive - perfect for the most luxurious retail shops and world renowned museums. Décor Series Ultra is designed as a replacement for halogen lamps Décor Series™ Food products offer color points developed to address the unique requirements of the food, grocery, and restaurant industries. Highlighting the distinctive colors and nuanced patterns found in meats and breads, the Décor Series Food products are a must have for any butcher counter or bakery. Décor Series ™ Entertainment products provide color points developed specifically for the healthcare and entertainment industries. The 5600K cool white color point combined with a CRI of 90 or 97 provides the bright white required by these industries. Décor Series™ Street and Landmark is designed to be a direct replacement for high pressure sodium lamps. Vero® Series

Features

  • Efficacy of 170 lm/W typical
  • Lumen output performance ranges from 3,850 to 38,400 lumens
  • Broad range of CCT options from 1750K to 6500K
  • CRI options include minimum 65, 70, 80, and 90, 2 and 3 SDCM color control for 2700K-4000K CCT
  • Reliable operation at up to 2X nominal drive current
  • Radial die pattern and improved lumen density
  • Thermally isolated solder pads
  • Onboard connector port
  • Top side part number markings
  • V f bin code backside marking Benefits
  • Broad application coverage for interior and exterior lighting
  • Flexibility for application driven lighting design requirements
  • High quality true color reproduction
  • Uniform consistent white light
  • Flexibility in design optimization
  • Enhanced ease of use and assembly
  • Solderless connectivity enables plug & play installation and field upgradability
  • Improved inventory management and quality control

The part number designation for Bridgelux Vero LED arrays is explained as follows: 1 2 3 4 5 6 7 8 9 10 11 – 12 – 13 14 Product Family CCT Bin Options 2 = 2 SDCM 3 = 3 SDCM 4 = 4 SDCM CRI B = 65 CRI min. C = 70 CRI min. E = 80 CRI min. G = 90 CRI min. H = 97 CRI typ. A = Class A Array Configuration 17 = 1,750K 20 = 2,000K 25 = 2,500K 27 = 2,700K 30 = 3,000K 35 = 3,500K 40 = 4,000K 50 = 5,000K 56 = 5,600K 57 = 5,700K 65 = 6,500K BXRC – 30 E 10K 0 – C – 7 3 Color Targeting Designator 0 = Cold Targeted 1 = Hot Targeted Gen. 7Nominal CCT Flux Indicator 10Kx = 10,000 lm Vero 29 is the largest form factor in the Vero family of next generation solid state light sources. In addition to delivering the performance and light quality required for many lighting applications, Vero incorporates several features to simplify the design integration and manufacturing process, accelerate time to market and reduce system costs. Please visit www.bridgelux.com for more information on the Vero Series family of products. Mounting holes Polarity indication marks simplify manufacturing operator instructions 2D Bar code provides full manufacturing traceability Solderless connector port enables simplified manufacturing processes, reduced inventory carrying costs and can enable field upgradability Thermally isolated solder pads reduce manufacturing cycle time and complexity Tc Measurement point Top side part number marking improves inventory management and outgoing quality control Radial die configuration improves lumen density and beam control Optional Bridgelux Vero wire harness (sold separately)

The following product configurations are available: Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-17E10K0-B-7x 1750 80 1800 8611 7750 52.0 93.6 92 BXRC-17E10K0-C-7x 1750 80 1710 10918 9826 69.4 118.7 92 BXRC-17E10K0-D-7x 1750 80 2100 7264 6538 37.6 79.0 92 BXRC-20B10K1-C-7x 2000 65 1710 18632 16769 69.4 118.7 157 BXRC-20B10K1-D-7x 2000 65 2100 12397 11157 37.6 79.0 157 BXRC-25E10K0-B-7x 2500 80 1800 14321 12889 52.0 93.6 153 BXRC-25E10K0-C-7x 2500 80 1710 18157 16341 69.4 118.7 153 BXRC-25E10K0-D-7x 2500 80 2100 12081 10873 37.6 79.0 153 BXRC-27E10K0-B-7x 2700 80 1800 14976 13478 52.0 93.6 160 BXRC-27E10K0-C-7x 2700 80 1710 18988 17089 69.4 118.7 160 BXRC-27E10K0-D-7x 2700 80 2100 12634 11370 37.6 79.0 160 BXRC-27G1KH0-B-7x 2700 90 1800 12823 11541 52.0 93.6 137 BXRC-27G1KH0-C-7x 2700 90 1710 16258 14633 69.4 118.7 137 BXRC-27G1KH0-D-7x 2700 90 2100 10818 9736 37.6 79.0 137 BXRC-27G10K0-B-7x 2700 90 1800 12355 11120 52.0 93.6 132 BXRC-27G10K0-C-7x 2700 90 1710 15665 14098 69.4 118.7 132 BXRC-27G10K0-D-7x 2700 90 2100 10423 9380 37.6 79.0 132 BXRC-27H10K0-D-7x 2700 97 2100 9243 8319 37.6 79.0 117 BXRC-30C10K1-B-7x 3000 70 1800 16661 14995 52.0 93.6 178 BXRC-30C10K1-C-7x 3000 70 1710 21124 19012 69.4 118.7 178 BXRC-30C10K1-D-7x 3000 70 2100 14055 12649 37.6 79.0 178 BXRC-30E10K0-B-7x10 3000 80 1800 15912 14321 52.0 93.6 170 BXRC-30E10K0-C-7x10 3000 80 1710 20175 18157 69.4 118.7 170 BXRC-30E10K0-D-7x10 3000 80 2100 13423 12081 37.6 79.0 170 BXRC-30G1KH0-B-7x 3000 90 1800 13478 12131 52.0 93.6 144 BXRC-30G1KH0-C-7x 3000 90 1710 17089 15380 69.4 118.7 144 BXRC-30G1KH0-D-7x 3000 90 2100 11370 10233 37.6 79.0 144 BXRC-30G10K0-B-7x 3000 90 1800 12917 11625 52.0 93.6 138 BXRC-30G10K0-C-7x 3000 90 1710 16377 14739 69.4 118.7 138 BXRC-30G10K0-D-7x 3000 90 2100 10896 9807 37.6 79.0 138 BXRC-30H10K0-D-7x 3000 97 2100 9870 8883 37.6 79.0 125 BXRC-30A10K1-B-7x8,9 3000 93 1800 11606 10446 52.0 93.6 124 BXRC-30A10K1-C-7x8,9 3000 93 1710 14716 13244 69.4 118.7 124 BXRC-30A10K1-D-7x8,9 3000 93 2100 9791 8812 37.6 79.0 124 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are typical for Décor Series Class A, Decor Series Street and Landmark and Décor Series Ultra products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ±3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance. 10. SKUs can meet DLC premium (Outdoor Mid Output) requirements under certain system level conditions.

Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-35E10K0-B-7x10 3500 80 1800 16286 14658 52.0 93.6 174 BXRC-35E10K0-C-7x10 3500 80 1710 20649 18584 69.4 118.7 174 BXRC-35E10K0-D-7x10 3500 80 2100 13739 12365 37.6 79.0 174 BXRC-35G10K0-B-7x 3500 90 1800 13385 12046 52.0 93.6 143 BXRC-35G10K0-C-7x 3500 90 1710 16970 15273 69.4 118.7 143 BXRC-35G10K0-D-7x 3500 90 2100 11291 10162 37.6 79.0 143 BXRC-35A10K1-B-7x8,9 3500 93 1800 12355 11120 52.0 93.6 132 BXRC-35A10K1-C-7x8,9 3500 93 1710 15665 14098 69.4 118.7 132 BXRC-35A10K1-D-7x8,9 3500 93 2100 10423 9380 37.6 79.0 132 BXRC-40C10K1-B-7x 4000 70 1800 17129 15416 52.0 93.6 183 BXRC-40C10K1-C-7x 4000 70 1710 21717 19546 69.4 118.7 183 BXRC-40C10K1-D-7x 4000 70 2100 14450 13005 37.6 79.0 183 BXRC-40E10K0-B-7x10 4000 80 1800 16380 14742 52.0 93.6 175 BXRC-40E10K0-C-7x10 4000 80 1710 20768 18691 69.4 118.7 175 BXRC-40E10K0-D-7x10 4000 80 2100 13818 12436 37.6 79.0 175 BXRC-40G10K0-B-7x 4000 90 1800 13666 12299 52.0 93.6 146 BXRC-40G10K0-C-7x 4000 90 1710 17326 15594 69.4 118.7 146 BXRC-40G10K0-D-7x 4000 90 2100 11528 10375 37.6 79.0 146 BXRC-40H10K0-D-7x 4000 97 2100 10423 9380 37.6 79.0 132 BXRC-40A10K1-B-738,9 4000 93 1800 13385 12046 52.0 93.6 143 BXRC-40A10K1-C-738,9 4000 93 1710 16970 15273 69.4 118.7 143 BXRC-40A10K1-D-738,9 4000 93 2100 11291 10162 37.6 79.0 143 BXRC-50C10K1-B-7x10 5000 70 1800 17222 15500 52.0 93.6 184 BXRC-50C10K1-C-7x10 5000 70 1710 21836 19652 69.4 118.7 184 BXRC-50C10K1-D-7x10 5000 70 2100 14529 13076 37.6 79.0 184 BXRC-50E10K1-B-7x 5000 80 1800 16567 14910 52.0 93.6 177 BXRC-50E10K1-C-7x 5000 80 1710 21005 18905 69.4 118.7 177 BXRC-50E10K1-D-7x 5000 80 2100 13976 12578 37.6 79.0 177 BXRC-50G10K1-B-7x 5000 90 1800 14321 12889 52.0 93.6 153 BXRC-50G10K1-C-7x 5000 90 1710 18157 16341 69.4 118.7 153 BXRC-50G10K1-D-7x 5000 90 2100 12081 10873 37.6 79.0 153 BXRC-56G10K0-B-7x 5600 90 1800 14414 12973 52.0 93.6 154 BXRC-56G10K0-C-7x 5600 90 1710 18276 16448 69.4 118.7 154 BXRC-56G10K0-D-7x 5600 90 2100 12160 10944 37.6 79.0 154 BXRC-56H10K1-D-7x 5600 97 2100 10975 9878 37.6 79.0 139 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are typical for Décor Series Class A, Decor Series Street and Landmark and Décor Series Ultra products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ±3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance. 10. SKUs can meet DLC premium (Outdoor Mid Output) requirements under certain system level conditions.

Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-57C10K1-B-7x10 5700 70 1800 16754 15079 52.0 93.6 179 BXRC-57C10K1-C-7x10 5700 70 1710 21243 19118 69.4 118.7 179 BXRC-57C10K1-D-7x10 5700 70 2100 14134 12720 37.6 79.0 179 BXRC-57E10K1-B-7x10 5700 80 1800 15912 14321 52.0 93.6 170 BXRC-57E10K1-C-7x10 5700 80 1710 20175 18157 69.4 118.7 170 BXRC-57E10K1-D-7x10 5700 80 2100 13423 12081 37.6 79.0 170 BXRC-65C10K1-B-7x10 6500 70 1800 16754 15079 52.0 93.6 179 BXRC-65C10K1-C-7x10 6500 70 1710 21243 19118 69.4 118.7 179 BXRC-65C10K1-D-7x10 6500 70 2100 14134 12720 37.6 79.0 179 BXRC-65E10K1-B-7x10 6500 80 1800 16099 14489 52.0 93.6 172 BXRC-65E10K1-C-7x10 6500 80 1710 20412 18371 69.4 118.7 172 BXRC-65E10K1-D-7x10 6500 80 2100 13581 12223 37.6 79.0 172 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are typical for Décor Series Class A, Decor Series Street and Landmark and Décor Series Ultra products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ±3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance. 10. SKUs can meet DLC premium (Outdoor Mid Output) requirements under certain system level conditions.

Table 2: Selection Guide, Stabilized DC Performance (Tc = 70°C) 7,8 Part Number Nominal CCT1 (K) GAI2 CRI3 Nominal Drive Current4 (mA) Typical DC Flux5,6 Tc = 70ºC (lm) Minimum DC Flux6,9 Tc = 70ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-30A10K1-B-7x 3000 80 93 1800 10794 9715 50.9 91.6 118 BXRC-30A10K1-C-7x 3000 80 93 1710 13685 12317 67.9 116.1 118 BXRC-30A10K1-D-7x 3000 80 93 2100 9106 8195 36.8 77.3 118 BXRC-35A10K1-B-7x 3500 80 93 1800 11490 10341 50.9 91.6 125 BXRC-35A10K1-C-7x 3500 80 93 1710 14568 13112 67.9 116.1 126 BXRC-35A10K1-D-7x 3500 80 93 2100 9693 8724 36.8 77.3 125 BXRC-40A10K1-B-7x 4000 80 93 1800 12448 11203 50.9 91.6 136 BXRC-40A10K1-C-7x 4000 80 93 1710 15782 14204 67.9 116.1 136 BXRC-40A10K1-D-7x 4000 80 93 2100 10501 9451 36.8 77.3 136 Notes for Table 2: 1. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 2. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance. 3. CRI Values are specified as typical. 4. Drive current is referred to as nominal drive current. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 8. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at specified temperature. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 9. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.

Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-17E10K0-B-7x 1750 80 1800 7750 6975 50.7 91.2 85 BXRC-17E10K0-C-7x 1750 80 1710 9826 8844 68.1 116.4 84 BXRC-17E10K0-D-7x 1750 80 2100 6538 5884 36.6 76.8 85 BXRC-20B10K0-C-73 2000 65 1710 16769 15092 68.1 116.4 144 BXRC-20B10K0-D-7x 2000 65 2100 11157 10041 36.6 76.8 145 BXRC-25E10K0-B-7x 2500 80 1800 12889 11600 50.7 91.2 141 BXRC-25E10K0-C-7x 2500 80 1710 16341 14707 68.1 116.4 140 BXRC-25E10K0-D-7x 2500 80 2100 10873 9786 36.6 76.8 142 BXRC-27E10K0-B-7x 2700 80 1800 13478 12131 50.7 91.2 148 BXRC-27E10K0-C-7x 2700 80 1710 17089 15380 68.1 116.4 147 BXRC-27E10K0-D-7x 2700 80 2100 11370 10233 36.6 76.8 148 BXRC-27G1KH0-B-7x 2700 90 1800 11541 10387 51.0 91.7 126 BXRC-27G1KH0-C-7x 2700 90 1710 14633 13169 68.4 116.9 125 BXRC-27G1KH0-D-7x 2700 90 2100 9736 8762 36.6 76.8 127 BXRC-27G10K0-B-7x 2700 90 1800 11120 10008 51.0 91.7 121 BXRC-27G10K0-C-7x 2700 90 1710 14098 12689 68.4 116.9 121 BXRC-27G10K0-D-7x 2700 90 2100 9380 8442 36.6 76.8 122 BXRC-27H10K0-D-7x 2700 97 2100 8319 7487 36.6 76.8 108 BXRC-30C10K1-B-7x 3000 70 1800 14995 13495 51.0 91.7 163 BXRC-30C10K1-C-7x 3000 70 1710 19012 17110 68.4 116.9 163 BXRC-30C10K1-D-7x 3000 70 2100 12649 11384 36.6 76.8 165 BXRC-30E10K0-B-7x 3000 80 1800 14321 12889 51.0 91.7 156 BXRC-30E10K0-C-7x 3000 80 1710 18157 16341 68.4 116.9 155 BXRC-30E10K0-D-7x 3000 80 2100 12081 10873 36.6 76.8 157 BXRC-30G1KH0-B-7x 3000 90 1800 12131 10918 51.0 91.7 132 BXRC-30G1KH0-C-7x 3000 90 1710 15380 13842 68.4 116.9 132 BXRC-30G1KH0-D-7x 3000 90 2100 10233 9210 36.6 76.8 133 BXRC-30G10K0-B-7x 3000 90 1800 11625 10463 50.7 91.2 127 BXRC-30G10K0-C-7x 3000 90 1710 14739 13265 68.1 116.4 127 BXRC-30G10K0-D-7x 3000 90 2100 9807 8826 36.6 76.8 128 BXRC-30H10K0-D-7X 3000 97 2100 8883 7995 36.6 76.9 116 BXRC-30A10K1-B-7x7,8 3000 93 1800 10446 9401 50.7 91.2 115 BXRC-30A10K1-C-7x7,8 3000 93 1710 13244 11920 68.1 116.4 114 BXRC-30A10K1-D-7x7,8 3000 93 2100 8812 7931 36.6 76.8 115 Notes for Table 3: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Décor Series Class A, Decor Series Street and Landmark and Décor Series Ultra products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ±3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance. x

Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-35E10K0-B-7X 3500 80 1800 14658 13192 50.7 91.2 161 BXRC-35E10K0-C-7X 3500 80 1710 18584 16726 68.1 116.4 160 BXRC-35E10K0-D-7X 3500 80 2100 12365 11129 36.6 76.8 161 BXRC-35G10K0-B-7X 3500 90 1800 12046 10842 50.7 91.2 132 BXRC-35G10K0-C-7X 3500 90 1710 15273 13746 68.1 116.4 131 BXRC-35G10K0-D-7X 3500 90 2100 10162 9146 36.6 76.8 132 BXRC-35A10K1-B-7x7,8 3500 93 1800 11120 10008 50.7 91.2 122 BXRC-35A10K1-C-7x7,8 3500 93 1710 14098 12689 68.1 116.4 121 BXRC-35A10K1-D-7x7,8 3500 93 2100 9380 8442 36.6 76.8 122 BXRC-40C10K1-B-7x 4000 70 1800 15416 13874 51.0 91.7 168 BXRC-40C10K1-C-7x 4000 70 1710 19546 17591 68.4 116.9 167 BXRC-40C10K1-D-7x 4000 70 2100 13005 11704 36.6 76.8 169 BXRC-40E10K0-B-7x 4000 80 1800 14742 13268 50.7 91.2 162 BXRC-40E10K0-C-7x 4000 80 1710 18691 16822 68.1 116.4 161 BXRC-40E10K0-D-7x 4000 80 2100 12436 11193 36.6 76.8 162 BXRC-40G10K0-B-7x 4000 90 1800 12299 11069 50.7 91.2 135 BXRC-40G10K0-C-7x 4000 90 1710 15594 14034 68.1 116.4 134 BXRC-40G10K0-D-7x 4000 90 2100 10375 9338 36.6 76.8 135 BXRC-40H10K0-D-7x 4000 97 2100 9380 8442 36.6 76.9 122 BXRC-40A10K1-B-7x7,8 4000 93 1800 12046 10842 50.7 91.2 132 BXRC-40A10K1-C-7x7,8 4000 93 1710 15273 13746 68.1 116.4 131 BXRC-40A10K1-D-7x7,8 4000 93 2100 10162 9146 36.6 76.8 132 BXRC-50C10K1-B-7x 5000 70 1800 15500 13950 50.7 91.2 170 BXRC-50C10K1-C-7x 5000 70 1710 19652 17687 68.1 116.4 169 BXRC-50C10K1-D-7x 5000 70 2100 13076 11768 36.6 76.8 170 BXRC-50E10K1-B-7x 5000 80 1800 14910 13419 50.7 91.2 163 BXRC-50E10K1-C-7x 5000 80 1710 18905 17014 68.1 116.4 162 BXRC-50E10K1-D-7x 5000 80 2100 12578 11320 36.6 76.8 164 BXRC-50G10K1-B-7x 5000 90 1800 12889 11600 50.7 91.2 141 BXRC-50G10K1-C-7x 5000 90 1710 16341 14707 68.1 116.4 140 BXRC-50G10K1-D-7x 5000 90 2100 10873 9786 36.6 76.8 142 BXRC-56G10K0-B-7x 5600 90 1800 12973 11676 50.7 91.2 142 BXRC-56G10K0-C-7x 5600 90 1710 16448 14803 68.1 116.4 141 BXRC-56G10K0-D-7x 5600 90 2100 10944 9849 36.6 76.8 143 BXRC-56H10K1-D-7x 5600 97 2100 9878 8890 36.6 76.9 129 Notes for Table 3: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Class A, Decor Series Street and Landmark and Décor Series Ultra products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ±3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance.

Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5(continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-57C10K1-B-7x 5700 70 1800 15079 13571 50.7 91.2 165 BXRC-57C10K1-C-7x 5700 70 1710 19118 17207 68.1 116.4 164 BXRC-57C10K1-D-7x 5700 70 2100 12720 11448 36.6 76.8 166 BXRC-57E10K1-B-7x 5700 80 1800 14321 12889 50.7 91.2 157 BXRC-57E10K1-C-7x 5700 80 1710 18157 16341 68.1 116.4 156 BXRC-57E10K1-D-7x 5700 80 2100 12081 10873 36.6 76.8 157 BXRC-65C10K1-B-7x 6500 70 1800 15079 13571 50.7 91.2 165 BXRC-65C10K1-C-7x 6500 70 1710 19118 17207 68.1 116.4 164 BXRC-65C10K1-D-7x 6500 70 2100 12720 11448 36.6 76.8 166 BXRC-65E10K1-B-7x 6500 80 1800 14489 13040 50.7 91.2 159 BXRC-65E10K1-C-7x 6500 80 1710 18371 16534 68.1 116.4 158 BXRC-65E10K1-D-7x 6500 80 2100 12223 11001 36.6 76.8 159 Notes for Table 3: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Décor Series Class A, Decor Series Street and Landmark and Décor Series Ultra products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ±3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance.

European Product Registry for Energy Labeling The European Product Registry for Energy Labeling (EPREL) is defined in the EU Regulation 2017/1369 to provide import- ant energy efficiency information to consumers. Together with Energy Labeling Regulation ELR (EU) 2019/2015 which was amended by regulation (EU) 2021/340 for energy labelling of light sources, manufacturers are required to declare an ener- gy class based on key technical specifications from each of their product and register it in an open data base managed by EPREL It is now a legal requirement for a vendor of light sources to upload information about their products into the EPREL database before placing these products on the market in the EU. Table 4 below provides a list of part numbers that are in compliance with ELR and are currently listed in the EPREL data- base. At Bridgelux, we are fully committed to supplying products that are compliant with pertinent laws, rules, and obligation imposed by relevant government bodies including the European Energy Labeling regulation. Customers can use these products with full confidence for any projects that fall under the ELR. Table 4: Part numbers registered in European Product Registry for Energy Labeling PART NUMBER1 CCT (K) CRI Current2 (mA) Vf (V) Useful flux3 (Φuse) at 85C (lm) Pow- er (W) Efficacy (lm/W) Energy efficiency class4 Regis- tration No URL to Product Information Sheet in EPREL Database Notes for Table 4: 1. All device listed here must be disposed as e-waste upon its end of life according to local country guideline in each country. 2. For information on performance values at alternative drive conditions. please refer to the Product Selection Guide, Absolute Maximum Rating Table and Performance Curves in this data sheet. 3. For a definition of useful luminous flux (ΦΦuse), please see the ELR regulations at https:/ /tinyurl.com/4b6zvt4m. 4. EPREL requires an arrow symbol containing the letter of the energy efficiency class to be displayed. on technical promotional material. Refer to this energy efficiency class column for specific energy efficiency class on each part number.

European Product Registry for Energy Labeling Table 4: Part numbers registered in European Product Registry for Energy Labeling (Continued) PART NUMBER1 CCT (K) CRI Current2 (mA) Vf (V) Useful flux3 (Φuse) at 85C (lm) Pow- er (W) Efficacy (lm/W) Energy efficiency class4 Regis- tration No URL to Product Information Sheet in EPREL Database Notes for Table 4: 1. All device listed here must be disposed as e-waste upon its end of life according to local country guideline in each country. 2. For information on performance values at alternative drive conditions. please refer to the Product Selection Guide, Absolute Maximum Rating Table and Performance Curves in this data sheet. 3. For a definition of useful luminous flux (ΦΦuse), please see the ELR regulations at https:/ /tinyurl.com/4b6zvt4m. 4. EPREL requires an arrow symbol containing the letter of the energy efficiency class to be displayed. on technical promotional material. Refer to this energy efficiency class column for specific energy efficiency class on each part number.

European Product Registry for Energy Labeling Table 4: Part numbers registered in European Product Registry for Energy Labeling (Continued) PART NUMBER1 CCT (K) CRI Current2 (mA) Vf (V) Useful flux3 (Φuse) at 85C (lm) Pow- er (W) Efficacy (lm/W) Energy efficiency class4 Regis- tration No URL to Product Information Sheet in EPREL Database Notes for Table 4: 1. All device listed here must be disposed as e-waste upon its end of life according to local country guideline in each country. 2. For information on performance values at alternative drive conditions. please refer to the Product Selection Guide, Absolute Maximum Rating Table and Performance Curves in this data sheet. 3. For a definition of useful luminous flux (ΦΦuse), please see the ELR regulations at https:/ /tinyurl.com/4b6zvt4m. 4. EPREL requires an arrow symbol containing the letter of the energy efficiency class to be displayed. on technical promotional material. Refer to this energy efficiency class column for specific energy efficiency class on each part number.

Performance at Commonly Used Drive Currents Vero LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. Vero may also be driven at other drive currents dependent on specific application design requirements. The performance at any drive current can be derived from the current vs. voltage characteristics shown in Figures 1, 2 & 3 and the flux vs. current characteristics shown in Figures 4, 5 & 6. The performance at commonly used drive currents is summarized in Table 5. Table 5: Product Performance at Commonly Used Drive Currents Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-17E10K0-B-7x 80 900 49.6 44.7 4470 4081 100 1200 50.5 60.6 5886 5350 97 1800 52.0 93.6 8611 7750 92 2700 54.1 146.1 12413 11070 85 3600 55.8 201.0 15887 13998 79 BXRC-17E10K0-C-7x 80 855 66.2 56.6 6202 5902 110 1140 67.3 76.7 7883 7272 103 1710 69.4 118.7 10918 9826 92 2565 72.1 185.0 15489 13321 84 3420 74.4 254.6 19413 16313 76 BXRC-17E10K0-D-7x 80 1050 35.4 37.2 3996 3893 107 1400 36.2 50.7 5142 4786 101 2100 37.6 78.9 7264 6538 92 3150 39.5 124.4 10342 8714 83 4200 41.2 173.0 13034 10644 75 BXRC-20B10K0-C-7x 65 855 66.2 56.6 10584 10072 187 1140 67.3 76.7 13452 12409 175 1710 69.4 118.7 18632 16769 157 2565 72.1 185.0 26432 22733 143 3420 74.4 254.6 33129 27838 130 BXRC-20B10K0-D-7x 65 1050 35.4 37.2 6819 6644 183 1400 36.2 50.7 8776 8167 173 2100 37.6 78.9 12397 11157 157 3150 39.5 124.4 17649 14870 142 4200 41.2 173.0 22243 18164 129 BXRC-25E10K0-B-7x 80 900 49.6 44.7 7434 6786 166 1200 50.5 60.6 9789 8898 162 1800 52.0 93.6 14321 12889 153 2700 54.1 146.1 20643 18410 141 3600 55.8 201.0 26421 23279 131 BXRC-25E10K0-C-7x 80 855 66.2 56.6 10315 9815 182 1140 67.3 76.7 13110 12093 171 1710 69.4 118.7 18157 16341 153 2565 72.1 185.0 25758 22154 139 3420 74.4 254.6 32285 27129 127 BXRC-25E10K0-D-7x 80 1050 35.4 37.2 6645 6475 179 1400 36.2 50.7 8552 7959 169 2100 37.6 78.9 12081 10873 153 3150 39.5 124.4 17199 14492 138 4200 41.2 173.0 21677 17701 125 Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-27E10K0-B-7x 80 900 49.6 44.7 7774 7097 174 1200 50.5 60.6 10237 9305 169 1800 52.0 93.6 14976 13478 160 2700 54.1 146.1 21588 19252 148 3600 55.8 201.0 27630 24344 137 BXRC-27E10K0-C-7x 80 855 66.2 56.6 10786 10264 191 1140 67.3 76.7 13709 12646 179 1710 69.4 118.7 18988 17089 160 2565 72.1 185.0 26937 23168 146 3420 74.4 254.6 33762 28370 133 BXRC-27E10K0-D-7x 80 1050 35.4 37.2 6949 6771 187 1400 36.2 50.6 8943 8323 177 2100 37.6 79.0 12634 11370 160 3150 39.5 124.4 17986 15155 145 4200 41.2 172.9 22668 18511 131 BXRC-27G1KH0-B-7x 90 900 49.6 44.7 6657 6076 149 1200 50.5 60.6 8765 7968 145 1800 52.0 93.6 12823 11541 137 2700 54.1 146.1 18484 16485 127 3600 55.8 201.0 23658 20844 118 BXRC-27G1KH0-C-7x 90 855 66.2 56.6 9236 8789 163 1140 67.3 76.7 11739 10828 153 1710 69.4 118.7 16258 14633 137 2565 72.1 185.0 23064 19837 125 3420 74.4 254.6 28909 24292 114 BXRC-27G1KH0-D-7x 90 1050 35.4 37.2 5950 5798 160 1400 36.2 50.6 7658 7127 151 2100 37.6 79.0 10818 9736 137 3150 39.5 124.4 15400 12976 124 4200 41.2 172.9 19410 15850 112 BXRC-27G10K0-B-7x 90 900 49.6 44.7 6414 5855 144 1200 50.5 60.6 8445 7677 139 1800 52.0 93.6 12355 11120 132 2700 54.1 146.1 17810 15883 122 3600 55.8 201.0 22795 20084 113 BXRC-27G10K0-C-7x 90 855 66.2 56.6 8899 8468 157 1140 67.3 76.7 11310 10433 147 1710 69.4 118.7 15665 14098 132 2565 72.1 185.0 22223 19113 120 3420 74.4 254.6 27854 23405 109 BXRC-27G10K0-D-7x 90 1050 35.4 37.2 5733 5586 154 1400 36.2 50.6 7378 6866 146 2100 37.6 79.0 10423 9380 132 3150 39.5 124.4 14838 12503 119 4200 41.2 172.9 18701 15271 108 Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-27H10K0-D-7x 97 1050 35.4 37.2 5084 4954 137 1400 36.2 50.6 6543 6089 129 2100 37.6 79.0 9243 8319 117 3150 39.5 124.4 13159 11087 106 4200 41.2 172.9 16585 13543 96 BXRC-30C10K1-B-7x 70 900 49.6 44.7 9464 9006 212 1200 50.5 60.6 12029 11096 199 1800 52.0 93.6 16661 14995 178 2700 54.1 146.1 23635 20328 162 3600 55.8 201.0 29625 24893 147 BXRC-30C10K1-C-7x 70 855 66.2 56.6 11619 11321 205 1140 67.3 76.7 14954 13916 195 1710 69.4 118.7 21124 19012 178 2565 72.1 185.0 30073 25339 163 3420 74.4 254.6 37903 30951 149 BXRC-30C10K1-D-7x 70 1050 35.4 37.2 7731 7533 208 1400 36.2 50.6 9949 9259 196 2100 37.6 79.0 14055 12649 178 3150 39.5 124.4 20009 16860 161 4200 41.2 172.9 25219 20593 146 BXRC-30E10K0-B-7x 80 900 49.6 44.7 8260 7540 185 1200 50.5 60.6 10876 9887 180 1800 52.0 93.6 15912 14321 170 2700 54.1 146.1 22937 20455 157 3600 55.8 201.0 29357 25865 146 BXRC-30E10K0-C-7x 80 855 66.2 56.6 11461 10906 203 1140 67.3 76.7 14566 13437 190 1710 69.4 118.7 20175 18157 170 2565 72.1 185.0 28620 24615 155 3420 74.4 254.6 35873 30143 141 BXRC-30E10K0-D-7x 80 1050 35.4 37.2 7383 7194 198 1400 36.2 50.6 9502 8843 188 2100 37.6 79.0 13423 12081 170 3150 39.5 124.4 19110 16102 154 4200 41.2 172.9 24085 19668 139 BXRC-30G1KH0-B-7X 90 900 49.6 44.7 6997 6387 157 1200 50.5 60.6 9213 8375 152 1800 52.0 93.6 13478 12131 144 2700 54.1 146.1 19429 17327 133 3600 55.8 201.0 24867 21909 124 BXRC-30G1KH0-C-7x 90 855 66.2 56.6 9708 9238 172 1140 67.3 76.7 12339 11382 161 1710 69.4 118.7 17089 15380 144 2565 72.1 185.0 24243 20851 131 3420 74.4 254.6 30386 25533 119 Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. Performance at Commonly Used Drive Currents

Performance at Commonly Used Drive Currents Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-30G1KH0-D-7x 90 1050 35.4 37.2 6254 6094 168 1400 36.2 50.6 8049 7491 159 2100 37.6 79.0 11370 10233 144 3150 39.5 124.4 16187 13639 130 4200 41.2 172.9 20402 16660 118 BXRC-30G10K0-B-7x 90 900 49.6 44.7 6705 6121 150 1200 50.5 60.6 8829 8026 146 1800 52.0 93.6 12917 11625 138 2700 54.1 146.1 18619 16605 127 3600 55.8 201.0 23831 20997 119 BXRC-30G10K0-C-7x 90 855 66.2 56.6 9303 8853 164 1140 67.3 76.7 11824 10907 154 1710 69.4 118.7 16377 14739 138 2565 72.1 185.0 23233 19982 126 3420 74.4 254.6 29120 24469 114 BXRC-30G10K0-D-7x 90 1050 35.4 37.2 5994 5840 161 1400 36.2 50.6 7714 7179 152 2100 37.6 79.0 10896 9807 138 3150 39.5 124.4 15513 13071 125 4200 41.2 172.9 19552 15966 113 BXRC-30H10K0-D-7x 97 1050 35.4 37.2 5429 5290 146 1400 36.2 50.6 6987 6502 138 2100 37.6 79.0 9870 8883 125 3150 39.5 124.4 14051 11840 113 4200 41.2 172.9 17710 14462 102 BXRC-30A10K1-B-7x 93 900 49.6 44.7 6025 5500 135 1200 50.5 60.6 7933 7212 131 1800 52.0 93.6 11606 10446 124 2700 54.1 146.1 16730 14920 115 3600 55.8 201.0 21413 18867 107 BXRC-30A10K1-C-7x 93 855 66.2 56.6 8359 7955 148 1140 67.3 76.7 10625 9801 139 1710 69.4 118.7 14716 13244 124 2565 72.1 185.0 20876 17955 113 3420 74.4 254.6 26166 21987 103 BXRC-30A10K1-D-7x 93 1050 35.4 37.2 5386 5248 145 1400 36.2 50.6 6931 6450 137 2100 37.6 79.0 9791 8812 124 3150 39.5 124.4 13939 11745 112 4200 41.2 172.9 17568 14346 102 BXRC-35E10K0-B-7x 80 900 49.6 44.7 8455 7718 189 1200 50.5 60.6 11132 10119 184 1800 52.0 93.6 16286 14658 174 2700 54.1 146.1 23477 20937 161 3600 55.8 201.0 30047 26474 149 Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-35E10K0-C-7x 80 855 66.2 56.6 11730 11162 207 1140 67.3 76.7 14909 13753 194 1710 69.4 118.7 20649 18584 174 2565 72.1 185.0 29294 25195 158 3420 74.4 254.6 36717 30852 144 BXRC-35E10K0-D-7x 80 1050 35.4 37.2 7557 7363 203 1400 36.2 50.6 9726 9051 192 2100 37.6 79.0 13739 12365 174 3150 39.5 124.4 19560 16481 157 4200 41.2 172.9 24652 20130 143 BXRC-35G10K0-B-7x 90 900 49.6 44.7 6948 6343 156 1200 50.5 60.6 9149 8317 151 1800 52.0 93.6 13385 12046 143 2700 54.1 146.1 19294 17207 132 3600 55.8 201.0 24694 21757 123 BXRC-35G10K0-C-7x 90 855 66.2 56.6 9640 9174 170 1140 67.3 76.7 12253 11302 160 1710 69.4 118.7 16970 15273 143 2565 72.1 185.0 24075 20706 130 3420 74.4 254.6 30175 25356 119 BXRC-35G10K0-D-7x 90 1050 35.4 37.2 6211 6052 167 1400 36.2 50.6 7993 7439 158 2100 37.6 79.0 11291 10162 143 3150 39.5 124.4 16075 13544 129 4200 41.2 172.9 20260 16544 117 BXRC-35A10K1-B-7x 93 900 49.6 44.7 6414 5855 144 1200 50.5 60.6 8445 7677 139 1800 52.0 93.6 12355 11120 132 2700 54.1 146.1 17810 15883 122 3600 55.8 201.0 22795 20084 113 BXRC-35A10K1-C-7x 93 855 66.2 56.6 8899 8468 157 1140 67.3 76.7 11310 10433 147 1710 69.4 118.7 15665 14098 132 2565 72.1 185.0 22223 19113 120 3420 74.4 254.6 27854 23405 109 BXRC-35A10K1-D-7x 93 1050 35.4 37.2 5733 5586 154 1400 36.2 50.6 7378 6866 146 2100 37.6 79.0 10423 9380 132 3150 39.5 124.4 14838 12503 119 4200 41.2 172.9 18701 15271 108 BXRC-40C10K1-B-7x 70 900 49.6 44.7 8892 8117 199 1200 50.5 60.6 11708 10643 193 1800 52.0 93.6 17129 15416 183 2700 54.1 146.1 24691 22020 169 3600 55.8 201.0 31602 27843 157 Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-40C10K1-C-7x 70 855 66.2 56.6 12337 11740 218 1140 67.3 76.7 15680 14464 204 1710 69.4 118.7 21717 19546 183 2565 72.1 185.0 30809 26498 167 3420 74.4 254.6 38616 32448 152 BXRC-40C10K1-D-7x 70 1050 35.4 37.2 7948 7744 214 1400 36.2 50.6 10229 9519 202 2100 37.6 79.0 14450 13005 183 3150 39.5 124.4 20571 17333 165 4200 41.2 172.9 25927 21172 150 BXRC-40E10K0-B-7x 80 900 49.6 44.7 8503 7762 190 1200 50.5 60.6 11196 10178 185 1800 52.0 93.6 16380 14742 175 2700 54.1 146.1 23611 21057 162 3600 55.8 201.0 30220 26626 150 BXRC-40E10K0-C-7x 80 855 66.2 56.6 11798 11227 209 1140 67.3 76.7 14995 13832 195 1710 69.4 118.7 20768 18691 175 2565 72.1 185.0 29462 25339 159 3420 74.4 254.6 36928 31030 145 BXRC-40E10K0-D-7x 80 1050 35.4 37.2 7601 7406 204 1400 36.2 50.6 9782 9103 193 2100 37.6 79.0 13818 12436 175 3150 39.5 124.4 19672 16575 158 4200 41.2 172.9 24794 20246 143 BXRC-40G10K0-B-7x 90 900 49.6 44.7 7094 6476 159 1200 50.5 60.6 9341 8491 154 1800 52.0 93.6 13666 12299 146 2700 54.1 146.1 19699 17568 135 3600 55.8 201.0 25212 22214 125 BXRC-40G10K0-C-7x 90 855 66.2 56.6 9843 9366 174 1140 67.3 76.7 12510 11540 163 1710 69.4 118.7 17326 15594 146 2565 72.1 185.0 24580 21140 133 3420 74.4 254.6 30808 25888 121 BXRC-40G10K0-D-7x 90 1050 35.4 37.2 6341 6179 170 1400 36.2 50.6 8161 7595 161 2100 37.6 79.0 11528 10375 146 3150 39.5 124.4 16412 13829 132 4200 41.2 172.9 20685 16891 120 BXRC-40H10K0-D-7x 97 1050 35.4 37.2 5733 5586 154 1400 36.2 50.6 7378 6866 146 2100 37.6 79.0 10423 9380 132 3150 39.5 124.4 14838 12503 119 4200 41.2 172.9 18701 15271 108 Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-40A10K1-B-7x 93 900 49.6 44.7 6948 6343 156 1200 50.5 60.6 9149 8317 151 1800 52.0 93.6 13385 12046 143 2700 54.1 146.1 19294 17207 132 3600 55.8 201.0 24694 21757 123 BXRC-40A10K1-C-7x 93 855 66.2 56.6 9640 9174 170 1140 67.3 76.7 12253 11302 160 1710 69.4 118.7 16970 15273 143 2565 72.1 185.0 24075 20706 130 3420 74.4 254.6 30175 25356 119 BXRC-40A10K1-D-7x 93 1050 35.4 37.2 6211 6052 167 1400 36.2 50.6 7993 7439 158 2100 37.6 79.0 11291 10162 143 3150 39.5 124.4 16075 13544 129 4200 41.2 172.9 20260 16544 117 BXRC-50C10K1-B-7x 70 900 49.6 44.7 8941 8161 200 1200 50.5 60.6 11772 10701 194 1800 52.0 93.6 17222 15500 184 2700 54.1 146.1 24826 22140 170 3600 55.8 201.0 31774 27995 158 BXRC-50C10K1-C-7x 70 855 66.2 56.6 12404 11804 219 1140 67.3 76.7 15766 14543 206 1710 69.4 118.7 21836 19652 184 2565 72.1 185.0 30977 26643 167 3420 74.4 254.6 38827 32625 153 BXRC-50C10K1-D-7x 70 1050 35.4 37.2 7991 7787 215 1400 36.2 50.6 10285 9571 203 2100 37.6 79.0 14529 13076 184 3150 39.5 124.4 20684 17428 166 4200 41.2 172.9 26069 21287 151 BXRC-50E10K1-B-7x 80 900 49.6 44.7 8600 7851 193 1200 50.5 60.6 11324 10294 187 1800 52.0 93.6 16567 14910 177 2700 54.1 146.1 23881 21298 164 3600 55.8 201.0 30565 26930 152 BXRC-50E10K1-C-7x 80 855 66.2 56.6 11932 11355 211 1140 67.3 76.7 15166 13990 198 1710 69.4 118.7 21005 18905 177 2565 72.1 185.0 29799 25629 161 3420 74.4 254.6 37350 31384 147 BXRC-50E10K1-D-7x 80 1050 35.4 37.2 7687 7490 207 1400 36.2 50.6 9894 9207 195 2100 37.6 79.0 13976 12578 177 3150 39.5 124.4 19897 16765 160 4200 41.2 172.9 25077 20478 145 Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-50G10K1-B-7x 90 900 49.6 44.7 7434 6786 166 1200 50.5 60.6 9789 8898 162 1800 52.0 93.6 14321 12889 153 2700 54.1 146.1 20643 18410 141 3600 55.8 201.0 26421 23279 131 BXRC-50G10K1-C-7x 90 855 66.2 56.6 10315 9815 182 1140 67.3 76.7 13110 12093 171 1710 69.4 118.7 18157 16341 153 2565 72.1 185.0 25758 22154 139 3420 74.4 254.6 32285 27129 127 BXRC-50G10K1-D-7x 90 1050 35.4 37.2 6645 6475 179 1400 36.2 50.6 8552 7959 169 2100 37.6 79.0 12081 10873 153 3150 39.5 124.4 17199 14492 138 4200 41.2 172.9 21677 17701 125 BXRC-56G10K0-B-7x 80 900 49.6 44.7 7483 6831 168 1200 50.5 60.6 9853 8956 163 1800 52.0 93.6 14414 12973 154 2700 54.1 146.1 20778 18530 142 3600 55.8 201.0 26594 23431 132 BXRC-56G10K0-C-7x 80 855 66.2 56.6 10382 9879 183 1140 67.3 76.7 13195 12172 172 1710 69.4 118.7 18276 16448 154 2565 72.1 185.0 25926 22299 140 3420 74.4 254.6 32496 27306 128 BXRC-56G10K0-D-7x 80 1050 35.4 37.2 6689 6517 180 1400 36.2 50.6 8608 8011 170 2100 37.6 79.0 12160 10944 154 3150 39.5 124.4 17311 14586 139 4200 41.2 172.9 21818 17817 126 BXRC-56H10K1-D-7x 97 1050 35.4 37.2 6037 5882 162 1400 36.2 50.6 7770 7231 153 2100 37.6 79.0 10975 9878 139 3150 39.5 124.4 15625 13166 126 4200 41.2 172.9 19693 16081 114 BXRC-57C10K1-B-7x 70 900 49.6 44.7 8698 7939 195 1200 50.5 60.6 11452 10410 189 1800 52.0 93.6 16754 15079 179 2700 54.1 146.1 24151 21538 165 3600 55.8 201.0 30911 27235 154 BXRC-57C10K1-C-7x 70 855 66.2 56.6 12067 11483 213 1140 67.3 76.7 15337 14148 200 1710 69.4 118.7 21243 19118 179 2565 72.1 185.0 30135 25919 163 3420 74.4 254.6 37772 31739 148 Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-57C10K1-D-7x 70 1050 35.4 37.2 7774 7575 209 1400 36.2 50.6 10005 9311 198 2100 37.6 79.0 14134 12720 179 3150 39.5 124.4 20122 16954 162 4200 41.2 172.9 25360 20709 147 BXRC-57E10K1-B-7x 80 900 49.6 44.7 8260 7540 185 1200 50.5 60.6 10876 9887 180 1800 52.0 93.6 15912 14321 170 2700 54.1 146.1 22937 20455 157 3600 55.8 201.0 29357 25865 146 BXRC-57E10K1-C-7x 80 855 66.2 56.6 11461 10906 203 1140 67.3 76.7 14566 13437 190 1710 69.4 118.7 20175 18157 170 2565 72.1 185.0 28620 24615 155 3420 74.4 254.6 35873 30143 141 BXRC-57E10K1-D-7x 80 1050 35.4 37.2 7383 7194 198 1400 36.2 50.6 9502 8843 188 2100 37.6 79.0 13423 12081 170 3150 39.5 124.4 19110 16102 154 4200 41.2 172.9 24085 19668 139 BXRC-65C10K1-B-7x 70 900 49.6 44.7 8698 7939 195 1200 50.5 60.6 11452 10410 189 1800 52.0 93.6 16754 15079 179 2700 54.1 146.1 24151 21538 165 3600 55.8 201.0 30911 27235 154 BXRC-65C10K1-C-7x 70 855 66.2 56.6 12067 11483 213 1140 67.3 76.7 15337 14148 200 1710 69.4 118.7 21243 19118 179 2565 72.1 185.0 30135 25919 163 3420 74.4 254.6 37772 31739 148 BXRC-65C10K1-D-7x 70 1050 35.4 37.2 7774 7575 209 1400 36.2 50.6 10005 9311 198 2100 37.6 79.0 14134 12720 179 3150 39.5 124.4 20122 16954 162 4200 41.2 172.9 25360 20709 147 BXRC-65E10K1-B-7x 80 900 49.6 44.7 8357 7629 187 1200 50.5 60.6 11004 10003 182 1800 52.0 93.6 16099 14489 172 2700 54.1 146.1 23207 20696 159 3600 55.8 201.0 29702 26170 148 BXRC-65E10K1-C-7x 80 855 66.2 56.6 11595 11034 205 1140 67.3 76.7 14738 13595 192 1710 69.4 118.7 20412 18371 172 2565 72.1 185.0 28957 24905 157 3420 74.4 254.6 36295 30498 143 Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-65E10K1-D-7x 80 1050 35.4 37.2 7470 7279 201 1400 36.2 50.6 9614 8947 190 2100 37.6 79.0 13581 12223 172 3150 39.5 124.4 19335 16291 155 4200 41.2 172.9 24369 19899 141 Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Electrical Characteristics

Table 6: Electrical Characteristics Part Number Drive Current (mA) Forward Voltage Pulsed, Tc = 25ºC (V) 1, 2, 3, 8 Typical Coefficient of Forward Voltage4 ∆Vf/∆Tc (mV/ºC) Typical Thermal Resistance Junction to Case5,6 Rj-c (ºC/W) Driver Selection Voltages7 (V) Minimum Typical Maximum Vf Min. Hot Tc = 105ºC (V) Vf Max. Cold Tc = -40ºC (V) BXRC-xxx10Kx-B-7x BXRC-xxx10Kx-C-7x BXRC-xxx10Kx-D-7x Notes for Table 6: 1. Parts are tested in pulsed conditions, Tc = 25°C. Pulse width is 10ms. 2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance. 3. Bridgelux maintains a tester tolerance of ± 0.10V on forward voltage measurements. 4. Typical coefficient of forward voltage tolerance is ± 0.1mV for nominal current. 5. Thermal resistance values are based from test data of a 3000K 80 CRI product. 6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal interface material used during testing is not included in the thermal resistance value. 7. Vf min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design and selection over the operating range of the product. 8. This product has been designed and manufactured per IEC 62031:2018. This product has passed dielectric withstand voltage testing at 1160 V. The work- ing voltage designated for the insulation is 80V d.c. The maximum allowable voltage across the array must be determined in the end product application.

Table 7: Eye Safety Risk Group (RG) Classifications Part Number Drive Current 5 (mA) CCT1,5 2700K/3000K 4000K2 5000K3 6500K4 BXRC-xxx10Kx-B-7x

1800 RG1 RG1 RG1 RG1

2700 RG1 RG1 RG2 RG2

3600 RG1 RG1 RG2 RG2

1710 RG1 RG1 RG1 RG2

2565 RG1 RG1 RG2 RG2

3420 RG1 RG2 RG2 RG2

2100 RG1 RG1 RG1 RG1

3150 RG1 RG1 RG1 RG2

4200 RG1 RG1 RG2 RG2

Notes for Table 7: 1. Eye safety classification for the use of Bridgelux Vero Series LED arrays is in accordance with specification IEC/TR 62778: Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires. 2. For products classified as RG2 at 4000K, Ethr= 1847.5 lx. 3. For products classified as RG2 at 5000K Ethr= 1315.8 lx. 4. For products classified as RG2 at 6500K, Ethr= 1124.5 lx. 5. Please contact your Bridgelux sales representative for Ethr values at specific drive currents and CCTs not listed

LED Junction Temperature (Tj) 150°C Storage Temperature -40°C to +105°C Operating Case Temperature1 (Tc) 105°C Soldering Temperature2 300°C or lower for a maximum of 6 seconds BXRC-xxx10Kx-B-7x BXRC-xxx10Kx-C-7x BXRC-xxx10Kx-D-7x Maximum Drive Current3 3600mA 3420mA 4200mA Maximum Peak Pulsed Drive Current4,5 5140mA 4890mA 6000mA Maximum Reverse Voltage6 -90V -120V -65V Notes for Table 8: 1. For IEC 62717 requirement, please consult your Bridgelux sales representative. 2. Refer to Bridgelux Application Note AN31: Assembly Considerations for Bridgelux Vero LED Arrays. 3. Arrays may be driven at higher currents however lumen maintenance may be reduced. 4. Per IEC 62031, LED Modules for General Lighting - Safety Specifications, the maximum allowable current when using the Molex Pico Connector is 3150mA. 5. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed current specified. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures. 6. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating provided for reference only. Table 8: Maximum Ratings

Notes for Figure 17: 1. The maximum allowable drive current for the Vero 29D product is dependent on the operating case temperature. Please refer to the Product Feature Map (page 2) for the location of the Tc Point 2. LM-80 Max Drive Current must not be exceeded in order to meet LM-80 lifetime projections. 3. Lumen maintenance (L70) and lifetime predictions are valid for drive current and case temperature conditions used for LM-80 testing as included in the applicable LM-80 test report for these products. Contact your Bridgelux sales representative for LM-80 report. 3200 3400 3600 3800 4000 4200 4400 0 10 20 30 40 50 60 70 80 90 100 110 Drive Current (mA) Case Temperature (⁰C) Max Drive Current LM-80 Max Drive Current 3960 Figure 17: Vero 29D Drive Current Derating Curve

Figure 22: Drawing for Vero 29 LED Array Notes for Figure 22: 1. Drawings are not to scale. 2. Drawing dimensions are in millimeters. 3. Unless otherwise specified, tolerances are ± 0.10mm. 4. Mounting holes (4X) are for M3 screws. 5. Bridgelux recommends four tapped holes for mounting screws with 43.0 ± 0.10mm center-to-center spacing. 6. Screws with flat shoulders (pan, dome, button, round, truss, mushroom) provide optimal torque control. Do NOT use flat, countersink, or raised head screws. 7. Solder pads and connector port are labeled “+” and “-“ to denote positive and negative, respectively. 8. It is not necessary to provide electrical connections to both the solder pads and the connector port. Either set may be used depending on application specific design requirements. 9. Refer to Application Notes AN30 and AN31 for product handling, mounting and heat sink recommendations. 10. The optical center of the LED Array is nominally defined by the mechanical center of the array to a tolerance of ± 0.2mm. 11. Bridgelux maintains a flatness of 0.10mm across the mounting surface of the array.

Figure 23: Graph of Warm and Neutral White Test Bins in xy Color Space Figure 24: Graph of Cool White Test Bins in xy Color Space Color Binning Information Bin Code 1750K 2000K 2500K 2700K 3000K1 3500K1 4000K1 ANSI Bin (for reference only) - - - (2580K - 2870K) (2870K - 3220K) (3220K - 3710K) (3710K - 4260K) 73 (3 SDCM) - - - (2651K - 2794K) (2968K - 3136K) (3369K - 3586K) (3851K - 4130K) 72 (2 SDCM) - - - (2674K - 2769K) (2995K - 3107K) (3404K - 3548K) (3895K - 4081K) Table 9: Warm and Neutral White xy Bin Coordinates and Associated Typical CCT Bin Code 5000K 5600K1 5700K 6500K ANSI Bin (for reference only) (4745K - 5311K) (5310K - 6020K) (5312K - 6022K) (6022K - 7042K) 74 (4 SDCM) (4801K - 5282K) (5475K - 5830K) (5395K- 5970K) (6200K - 6910K) 73 (3 SDCM) (4835K - 5215K) (5490K - 5820K) (5460K- 5891K) (6279K -6811K) Table 10: Cool White xy Bin Coordinates and Associated Typical CCT (product is hot targeted to Tc = 85°C) Note: Pulsed Test Conditions, Tc = 25°C Note: Pulsed Test Conditions, Tc = 25°C Note: Pulsed Test Conditions, Tc = 25°C Notes for Table 10: 1. Select configurations with a CCT of 5600K are available with center point targets at Tc = 85°C or Tc = 25°C. 2. Bridgelux maintains a tolerance of +/- 0.007 on x and y color coordinates in the CIE 1931 color Space. Notes for Table 9: 1. Color Binning information excludes Decor Series Class A products. Please contact your Bridgelux Sales Representative for more information. 2. Bridgelux maintains a tolerance of +/- 0.007 on x and y color coordinates in the CIE 1931 color Space. 0.34 0.36 0.38 0.4 0.42 0.44 Y X

3 SDCM

4 SDCM

0.3 0.31 0.32 0.33 0.34 0.35 0.36 0.37 0.38 0.39 Y X

Figure 25: Drawing for Vero 29 Packaging Tray Notes for Figure 25: 1. Dimensions are in millimeters. 2. Drawings are not to scale.

Bridgelux has developed a comprehensive set of application notes and design resources to assist customers in successfully designing with the Vero product family of LED array products. For all available application notes visit www.bridgelux.com. Optical Source Models Optical source models and ray set files are available for all Bridgelux products. For a list of available formats, visit www.bridgelux.com. MINOR PRODUCT CHANGE POLICY The rigorous qualification testing on products offered by Bridgelux provides performance assurance. Slight cosmetic changes that do not affect form, fit, or function may occur as Bridgelux continues product optimization. CAUTION: CHEMICAL EXPOSURE HAZARD Exposure to some chemicals commonly used in luminaire manufacturing and assembly can cause damage to the LED array. Please consult Bridgelux CAUTION: RISK OF BURN Do not touch the Vero LED array during operation. Allow the array to cool for a sufficient period of time before handling. The Vero LED array may reach elevated temperatures such that could burn skin when touched. 3D CAD Models Three dimensional CAD models depicting the product outline of all Bridgelux Vero LED arrays are available in both IGS and STEP formats. Please contact your Bridgelux sales representative for assistance. LM80 LM80 testing has been completed and the LM80 report is now available. Please contact your Bridgelux sales rep- resentative for LM-80 report. CAUTION CONTACT WITH LIGHT EMITTING SURFACE (LES) Avoid any contact with the LES. Do not touch the LES of the LED array or apply stress to the LES (yellow phosphor resin area). Contact may cause damage to the LED array. Optics and reflectors must not be mounted in contact with the LES (yellow phosphor resin area). Optical devices may be mounted on the top surface of the plastic housing of the Vero LED array. Use the mechanical features of the LED array housing, edges and/or mounting holes to locate and secure optical devices as needed. STANDARD TEST CONDITIONS Unless otherwise stated, array testing is performed at the nominal drive current.

About Bridgelux: Bridging Light and Life™ © 2023 Bridgelux, Inc. All rights reserved. Product specifications are subject to change without notice. Bridgelux, the Bridgelux stylized logo design, Vero, V Series and V Series HD are registered trademarks, and Decor Series is a trademark of Bridgelux, Inc. All other trademarks are the property of their respective owners.. Bridgelux Gen 7 Vero 29 Array Series Product Data Sheet DS93 Rev. T (08/2023)

46410 Fremont Boulevard

Fremont, CA 94538 U.S.A. Tel (925) 583-8400 www.bridgelux.com At Bridgelux, we help companies, industries and people experience the power and possibility of light. Since 2002, we’ve designed LED solutions that are high performing, energy efficient, cost effective and easy to integrate. Our focus is on light’s impact on human behavior, delivering products that create better environments, experiences and returns—both experiential and financial. And our patented technology drives new platforms for commercial and industrial luminaires. For more information about the company, please visit bridgelux.com twitter.com/Bridgelux facebook.com/Bridgelux youtube.com/user/Bridgelux linkedin.com/company/bridgelux-inc-_2 WeChat ID: BridgeluxInChina