DS92 BRIDGELUX | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 39
Technical content
Datasheet sections
18 Array
Vero® Series is a revolutionary advancement in chip on board (COB) light source technology and innovation. Vero LED light sources simplify luminaire design and manufacturing processes Vero Chip on Board (COB) LED arrays are available in four LES configurations, engineered to enable new degrees of flexibility and reliability over a broad range of electrical currents. Vero arrays deliver increased lumen density to enable improved beam control and precision lighting with 2 and 3 SDCM color control standard for clean and consistent uniform lighting. Vero products include an onboard connector port that enables a solder-free electrical interconnect, and simple mounting features for plug-and-play installation. Bridgelux Décor Series™ is our state-of-the-art color line designed specifically for premium applications, producing unmatched LED light quality with brilliant color-rendering options and pleasing lighting palettes. Bridgelux Décor Series color points are available on Vero® SE Series, Vero® Series, V Series™ and V Series™ HD. Décor Series™ Class A is based on human response testing, providing color points with a combined GAI and CRI metric. Décor Series™ Ultra products provide a high CRI of 97 and typical R9 value of 98, which emphasizes the reds and color tones to which the human eye is most receptive - perfect for the most luxurious retail shops and world renowned museums. Décor Series Ultra is designed as a replacement for halogen lamps. Décor Series™ Food products offer color points developed to address the unique requirements of the food, grocery, and restaurant industries. Highlighting the distinctive colors and nuanced patterns found in meats and breads, the Décor Series Food products are a must have for any butcher counter or bakery. Décor Series ™ Entertainment products provide color points developed specifically for the healthcare and entertainment industries. The 5600K cool white color point combined with a CRI of 90 or 97 provides the bright white required by these industries. Décor Series™ Street and Landmark is designed to be a direct replacement for high pressure sodium lamps. Décor Series™ Showcase is the optimal solution for replacing ceramic metal halide lamps, incorporating the same pure white light with enhanced spectrum coverage and higher efficacy. Vero® Series
Features
- Efficacy of 170 lm/W typical for 3000K 80 CRI
- Lumen output performance ranges from 1,455 to 13,600 lumens
- Broad range of CCT options from 1750K to 6500K
- CRI options include minimum 65, 70, 80, 90, 95 and Class A
- Reliable operation at up to 2X nominal drive current
- Radial die pattern and improved lumen density
- Thermally isolated solder pads
- Onboard connector port
- Top side part number markings
- V f bin code backside marking Benefits
- Broad application coverage for interior and exterior lighting
- Flexibility for application driven lighting design requirements
- High quality true color reproduction
- Uniform consistent white light
- Flexibility in design optimization
- Enhanced ease of use and assembly
- Solderless connectivity enables plug & play installation and field upgradability
- Improved inventory management and quality control
Vero 18 is the second largest form factor in the Vero family of next generation solid state light sources. In addition to delivering the performance and light quality required for many lighting applications, Vero incorporates Product Nomenclature The part number designation for Bridgelux Vero LED arrays is explained as follows: several features to simplify the design integration and manufacturing process, accelerate time to market and reduce system costs. Please visit www.bridgelux.com for more information on the Vero Series family of products. 1 2 3 4 5 6 7 8 9 10 11 – 12 – 13 14 Product Family CCT Bin Options 2 = 2 SDCM 3 = 3 SDCM 4 = 4 SDCM CRI B = 65 CRI min. C = 70 CRI min. E = 80 CRI min. G = 90 CRI min. H = 97 CRI typ. A = Class A Array Configuration 17 = 1,750K 20 = 2,000K 25 = 2,500K 27 = 2,700K 30 = 3,000K 35 = 3,500K 40 = 4,000K 50 = 5,000K 56 = 5,600K 57 = 5,700K 65 = 6,500K BXRC – 30 E 400 0 – C – 7 3 2D Bar code provides full manufacturing traceability Polarity indication marks simplify manufacturing operator instructions Optics location/mounting features Mounting holes Zhaga Book 3 compatible mounting locations Solderless connector port enables simplified manufacturing processes, reduced inventory carrying costs and can enable field upgradability Thermally isolated solder pads reduce manufacturing cycle time and complexity Tc Measurement point Radial die configuration improves lumen density and beam control Top side part number marking improves inventory management and outgoing quality control Color Targeting Designator 0 = Cold Targeted 1 = Hot Targeted C = Decor Series Showcase Target Gen. 7Nominal CCT Flux Indicator 400x = 4000 lm Optional Bridgelux Vero wire harness (sold separately)
The following product configurations are available: Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-17E4000-B-7x 1750 80 900 2881 2593 34.8 31.3 92 BXRC-17E4000-C-7x 1750 80 1170 3624 3261 34.8 40.7 89 BXRC-17E4000-D-7x 1750 80 1050 2710 2439 29.0 30.5 89 BXRC-20B4001-C-7x 2000 65 1170 6392 5753 34.8 40.7 157 BXRC-20B4001-D-7x 2000 65 1050 4781 4303 29.0 30.5 157 BXRC-25E4000-B-7x 2500 80 900 4792 4313 34.8 31.3 153 BXRC-25E4000-C-7x 2500 80 1170 6230 5607 34.8 40.7 153 BXRC-25E4000-D-7x 2500 80 1050 4659 4193 29.0 30.5 153 BXRC-27E4000-B-7x 2700 80 900 5011 4510 34.8 31.3 160 BXRC-27E4000-C-7x 2700 80 1170 6515 5863 34.8 40.7 160 BXRC-27E4000-D-7x 2700 80 1050 4872 4385 29.0 30.5 160 BXRC-27G40H0-B-7x 2700 90 900 4291 3862 34.8 31.3 137 BXRC-27G40H0-C-7x 2700 90 1170 5578 5020 34.8 40.7 137 BXRC-27G40H0-D-7x 2700 90 1050 4172 3754 29.0 30.5 137 BXRC-27G4000-B-7x 2700 90 900 4134 3721 34.8 31.3 132 BXRC-27G4000-C-7x 2700 90 1170 5375 4837 34.8 40.7 132 BXRC-27G4000-D-7x 2700 90 1050 4019 3617 29.0 30.5 132 BXRC-27H4000-B-7x 2700 97 900 3664 3298 34.8 31.3 117 BXRC-27H4000-C-7x 2700 97 1170 4764 4287 34.8 40.7 117 BXRC-27H4000-D-7x 2700 97 1050 3563 3206 29.0 30.5 117 BXRC-30C4001-B-7x 3000 70 900 5575 5017 34.8 31.3 178 BXRC-30C4001-C-7x 3000 70 1170 7247 6523 34.8 40.7 178 BXRC-30C4001-D-7x 3000 70 1050 5420 4878 29.0 30.5 178 BXRC-30E4000-B-7x 3000 80 900 5324 4792 34.8 31.3 170 BXRC-30E4000-C-7x 3000 80 1170 6922 6230 34.8 40.7 170 BXRC-30E4000-D-7x 3000 80 1050 5177 4659 29.0 30.5 170 BXRC-30G40H0-B-7x 3000 90 900 4322 3890 34.8 31.3 138 BXRC-30G40H0-C-7x 3000 90 1170 5619 5057 34.8 40.7 138 BXRC-30G40H0-D-7x 3000 90 1050 4202 3782 29.0 30.5 138 BXRC-30G4000-B-7x 3000 90 900 4510 4059 34.8 31.3 144 BXRC-30G4000-C-7x 3000 90 1170 5863 5277 34.8 40.7 144 BXRC-30G4000-D-7x 3000 90 1050 4385 3946 29.0 30.5 144 BXRC-30G400C-B-7x 3000 90 900 4166 3749 34.8 31.3 133 BXRC-30G400C-D-7x 3000 90 1050 4050 3645 29.0 30.5 133 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Brid- gelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance.
Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-30H4000-B-7x 3000 97 900 3915 3524 34.8 31.3 125 BXRC-30H4000-C-7x 3000 97 1170 5090 4581 34.8 40.7 125 BXRC-30H4000-D-7x 3000 97 1050 3806 3426 29.0 30.5 125 BXRC-30A4001-B-7x8,9 3000 93 900 3884 3495 34.8 31.3 124 BXRC-30A4001-C-7x8,9 3000 93 1170 5049 4544 34.8 40.7 124 BXRC-30A4001-D-7x8,9 3000 93 1050 3776 3398 29.0 30.5 124 BXRC-35E4000-B-7x 3500 80 900 5450 4905 34.8 31.3 174 BXRC-35E4000-C-7x 3500 80 1170 7085 6376 34.8 40.7 174 BXRC-35E4000-D-7x 3500 80 1050 5298 4768 29.0 30.5 174 BXRC-35G4000-B-7x 3500 90 900 4479 4031 34.8 31.3 143 BXRC-35G4000-C-7x 3500 90 1170 5822 5240 34.8 40.7 143 BXRC-35G4000-D-7x 3500 90 1050 4354 3919 29.0 30.5 143 BXRC-35A4001-B-7x8,9 3500 93 900 4134 3721 34.8 31.3 132 BXRC-35A4001-C-7x8,9 3500 93 1170 5375 4837 34.8 40.7 132 BXRC-35A4001-D-7x8,9 3500 93 1050 4019 3617 29.0 30.5 132 BXRC-40C4001-B-7x 4000 70 900 5732 5158 34.8 31.3 183 BXRC-40C4001-C-7x 4000 70 1170 7451 6706 34.8 40.7 183 BXRC-40C4001-D-7x 4000 70 1050 5572 5015 29.0 30.5 183 BXRC-40E4000-B-7x 4000 80 900 5481 4933 34.8 31.3 175 BXRC-40E4000-C-7x 4000 80 1170 7125 6413 34.8 40.7 175 BXRC-40E4000-D-7x 4000 80 1050 5329 4796 29.0 30.5 175 BXRC-40G4000-B-7x 4000 90 900 4573 4115 34.8 31.3 146 BXRC-40G4000-C-7x 4000 90 1170 5945 5350 34.8 40.7 146 BXRC-40G4000-D-7x 4000 90 1050 4446 4001 29.0 30.5 146 BXRC-40H4000-B-73 4000 97 900 4134 3721 34.8 31.3 132 BXRC-40H4000-C-73 4000 97 1170 5375 4837 34.8 40.7 132 BXRC-40H4000-D-73 4000 97 1050 4019 3617 29.0 30.5 132 BXRC-40A4001-B-7x8,9 4000 93 900 4479 4031 34.8 31.3 143 BXRC-40A4001-C-7x8,9 4000 93 1170 5822 5240 34.8 40.7 143 BXRC-40A4001-D-7x8,9 4000 93 1050 4354 3919 29.0 30.5 143 BXRC-50C4001-B-7x 5000 70 900 5763 5187 34.8 31.3 184 BXRC-50C4001-C-7x 5000 70 1170 7492 6743 34.8 40.7 184 BXRC-50C4001-D-7x 5000 70 1050 5603 5043 29.0 30.5 184 BXRC-50E4001-B-7x 5000 80 900 5544 4989 34.8 31.3 177 BXRC-50E4001-C-7x 5000 80 1170 7207 6486 34.8 40.7 177 BXRC-50E4001-D-7x 5000 80 1050 5390 4851 29.0 30.5 177 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ±3 tolerance for all CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance.
Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-50G4001-B-7x 5000 90 900 4792 4313 34.8 31.3 153 BXRC-50G4001-C-7x 5000 90 1170 5919 5327 34.8 40.7 153 BXRC-50G4001-D-7x 5000 90 1050 4659 4193 29.0 30.5 153 BXRC-56G4000-B-7x 5600 90 900 4823 4341 34.8 31.3 154 BXRC-56G4000-C-7x 5600 90 1170 6270 5643 34.8 40.7 154 BXRC-56G400x-D-7x 5600 90 1050 4689 4220 29.0 30.5 154 BXRC-56H4000-D-7x 5600 97 1050 4233 3809 29.0 30.5 139 BXRC-57C4001-B-7x 5700 70 900 5606 5046 34.8 31.3 179 BXRC-57C4001-C-7x 5700 70 1170 7288 6559 34.8 40.7 179 BXRC-57C4001-D-7x 5700 70 1050 5451 4905 29.0 30.5 179 BXRC-57E4001-B-7x 5700 80 900 5324 4792 34.8 31.3 170 BXRC-57E4001-C-7x 5700 80 1170 6922 6230 34.8 40.7 170 BXRC-57E4001-D-7x 5700 80 1050 5177 4659 29.0 30.5 170 BXRC-65C4001-B-7x 6500 70 900 5606 5046 34.8 31.3 179 BXRC-65C4001-C-7x 6500 70 1170 7288 6559 34.8 40.7 179 BXRC-65C4001-D-7x 6500 70 1050 5451 4905 29.0 30.5 179 BXRC-65E4001-B-7x 6500 80 900 5387 4848 34.8 31.3 172 BXRC-65E4001-C-7x 6500 80 1170 7003 6303 34.8 40.7 172 BXRC-65E4001-D-7x 6500 80 1050 5237 4714 29.0 30.5 172 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ±3 tolerance for all CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance.
Table 2: Selection Guide, Stabilized DC Performance (Tc = 70°C) 7,8 Part Number Nominal CCT1 (K) GAI2 CRI3 Nominal Drive Current4 (mA) Typical DC Flux5,6 Tc = 70ºC (lm) Minimum DC Flux6,9 Tc = 70ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-30A4001-B-7x 3000 80 93 900 3612 3251 34.3 30.9 116 BXRC-30A4001-C-7x 3000 80 93 1170 4695 4226 34.3 40.2 116 BXRC-30A4001-D-7x 3000 80 93 1050 3511 3160 28.5 29.9 116 BXRC-35A4001-B-7x 3500 80 93 900 3845 3460 34.3 30.9 123 BXRC-35A4001-C-7x 3500 80 93 1170 4998 4498 34.3 40.2 123 BXRC-35A4001-D-7x 3500 80 93 1050 3738 3364 28.5 29.9 123 BXRC-40A4001-B-7x 4000 80 93 900 4165 3749 34.3 30.9 133 BXRC-40A4001-C-7x 4000 80 93 1170 5415 4873 34.3 40.2 133 BXRC-40A4001-D-7x 4000 80 93 1050 4050 3645 28.5 29.9 133 Notes for Table 2: 1. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 2. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance. 3. CRI Values are specified as typical. 4. Drive current is referred to as nominal drive current. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 8. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at specified temperature. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 9. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-17E4000-B-7x 1750 80 900 2593 2334 33.9 30.5 85 BXRC-17E4000-C-7x 1750 80 1170 3261 2935 33.9 39.7 82 BXRC-17E4000-D-7x 1750 80 1050 2439 2195 28.1 29.5 83 BXRC-20B4001-C-7x 2000 65 1170 5753 5178 33.9 39.7 145 BXRC-20B4001-D-7x 2000 65 1050 4303 3872 28.1 29.5 146 BXRC-25E4000-B-7x 2500 80 900 4313 3881 33.9 30.5 141 BXRC-25E4000-C-7x 2500 80 1170 5607 5046 33.9 39.7 141 BXRC-25E4000-D-7x 2500 80 1050 4193 3774 28.1 29.5 142 BXRC-27E4000-B-7x 2700 80 900 4510 4059 33.9 30.5 148 BXRC-27E4000-C-7x 2700 80 1170 5863 5277 33.9 39.7 148 BXRC-27E4000-D-7x 2700 80 1050 4385 3946 28.1 29.5 149 BXRC-27G40H0-B-7x 2700 90 900 3862 3476 33.9 30.5 127 BXRC-27G40H0-C-7x 2700 90 1170 5020 4518 33.9 39.7 127 BXRC-27G40H0-D-7x 2700 90 1050 3754 3379 28.1 29.5 127 BXRC-27G4000-B-7x 2700 90 900 3721 3349 33.9 30.5 122 BXRC-27G4000-C-7x 2700 90 1170 4837 4353 33.9 39.7 122 BXRC-27G4000-D-7x 2700 90 1050 3617 3256 28.1 29.5 123 BXRC-27H4000-B-7x 2700 97 900 3298 2968 33.9 30.5 108 BXRC-27H4000-C-7x 2700 97 1170 4287 3859 33.9 39.7 108 BXRC-27H4000-D-7x 2700 97 1050 3206 2886 28.1 29.5 109 BXRC-30C4001-B-7x 3000 70 900 5017 4516 33.9 30.5 164 BXRC-30C4001-C-7x 3000 70 1170 6523 5870 33.9 39.7 164 BXRC-30C4001-D-7x 3000 70 1050 4878 4390 28.1 29.5 165 BXRC-30E4000-B-7x 3000 80 900 4792 4313 33.9 30.5 157 BXRC-30E4000-C-7x 3000 80 1170 6230 5607 33.9 39.7 157 BXRC-30E4000-D-7x 3000 80 1050 4659 4193 28.1 29.5 158 BXRC-30G40H0-B-7x 3000 90 900 3890 3501 33.9 30.5 127 BXRC-30G40H0-C-7x 3000 90 1170 5057 4551 33.9 39.7 127 BXRC-30G40H0-D-7x 3000 90 1050 3782 3404 28.1 29.5 128 BXRC-30G4000-B-7x 3000 90 900 4059 3653 33.9 30.5 133 BXRC-30G4000-C-7x 3000 90 1170 5277 4749 33.9 39.7 133 BXRC-30G4000-D-7x 3000 90 1050 3946 3552 28.1 29.5 134 BXRC-30G400C-B-7x 3000 90 900 3749 3374 33.9 30.5 123 BXRC-30G400C-D-7x 3000 90 1050 3645 3280 28.1 29.5 124 BXRC-30H4000-B-7x 3000 97 900 3524 3171 33.9 30.5 115 Notes for Table 3: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ±3 tolerance for all CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance.
Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-30H4000-C-7x 3000 97 1170 4581 4122 33.9 39.7 115 BXRC-30H4000-D-7x 3000 97 1050 3426 3083 28.1 29.5 116 BXRC-30A4001-B-7x8,9 3000 93 900 3495 3146 33.9 30.5 115 BXRC-30A4001-C-7x8,9 3000 93 1170 4544 4090 33.9 39.7 115 BXRC-30A4001-D-7x8,9 3000 93 1050 3398 3058 28.1 29.5 115 BXRC-35E4000-B-7x 3500 80 900 4905 4414 33.9 30.5 161 BXRC-35E4000-C-7x 3500 80 1170 6376 5739 33.9 39.7 161 BXRC-35E4000-D-7x 3500 80 1050 4768 4292 28.1 29.5 162 BXRC-35G4000-B-7x 3500 90 900 4031 3628 33.9 30.5 132 BXRC-35G4000-C-7x 3500 90 1170 5240 4716 33.9 39.7 132 BXRC-35G4000-D-7x 3500 90 1050 3919 3527 28.1 29.5 133 BXRC-35A4001-B-7x8,9 3500 93 900 3721 3349 33.9 30.5 122 BXRC-35A4001-C-7x8,9 3500 93 1170 4837 4353 33.9 39.7 122 BXRC-35A4001-D-7x8,9 3500 93 1050 3617 3256 28.1 29.5 123 BXRC-40C4001-B-7x 4000 70 900 5158 4643 33.9 30.5 169 BXRC-40C4001-C-7x 4000 70 1170 6706 6035 33.9 39.7 169 BXRC-40C4001-D-7x 4000 70 1050 5015 4514 28.1 29.5 170 BXRC-40E4000-B-7x 4000 80 900 4933 4440 33.9 30.5 162 BXRC-40E4000-C-7x 4000 80 1170 6413 5771 33.9 39.7 162 BXRC-40E4000-D-7x 4000 80 1050 4796 4316 28.1 29.5 163 BXRC-40G4000-B-7x 4000 90 900 4115 3704 33.9 30.5 135 BXRC-40G4000-C-7x 4000 90 1170 5350 4815 33.9 39.7 135 BXRC-40G4000-D-7x 4000 90 1050 4001 3601 28.1 29.5 136 BXRC-40H4000-B-7x 4000 97 900 3721 3349 33.9 30.5 122 BXRC-40H4000-C-7x 4000 97 1170 4837 4353 33.9 39.7 122 BXRC-40H4000-D-7x 4000 97 1050 3617 3256 28.1 29.5 123 BXRC-40A4001-B-7x7,8 4000 93 900 4031 3628 33.9 30.5 132 BXRC-40A4001-C-7x7,8 4000 93 1170 5240 4716 33.9 39.7 132 BXRC-40A4001-D-7x7,8 4000 93 1050 3919 3527 28.1 29.5 133 BXRC-50C4001-B-7x 5000 70 900 5187 4668 33.9 30.5 170 BXRC-50C4001-C-7x 5000 70 1170 6743 6068 33.9 39.7 170 BXRC-50C4001-D-7x 5000 70 1050 5043 4538 28.1 29.5 171 BXRC-50E4001-B-7x 5000 80 900 4989 4490 33.9 30.5 164 BXRC-50E4001-C-7x 5000 80 1170 6486 5837 33.9 39.7 164 BXRC-50E4001-D-7x 5000 80 1050 4851 4366 28.1 29.5 164 Notes for Table 3: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ±3 tolerance for all CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance.
Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-50G4001-B-7x 5000 90 900 4313 3881 33.9 30.5 141 BXRC-50G4001-C-7x 5000 90 1170 5327 4794 33.9 39.7 141 BXRC-50G4001-D-7x 5000 90 1050 4193 3774 28.1 29.5 142 BXRC-56G4000-B-7x 5600 90 900 4341 3907 33.9 30.5 142 BXRC-56G4000-C-7x 5600 90 1170 5643 5079 33.9 39.7 142 BXRC-56G400x-D-7x 5600 90 1050 4220 3798 28.1 29.5 143 BXRC-56H4000-D-7x 5600 97 1050 3809 3428 28.1 29.5 129 BXRC-57C4001-B-7x 5700 70 900 5046 4541 33.9 30.5 165 BXRC-57C4001-C-7x 5700 70 1170 6559 5903 33.9 39.7 165 BXRC-57C4001-D-7x 5700 70 1050 4905 4415 28.1 29.5 166 BXRC-57E4001-B-7x 5700 80 900 4792 4313 33.9 30.5 157 BXRC-57E4001-C-7x 5700 80 1170 6230 5607 33.9 39.7 157 BXRC-57E4001-D-7x 5700 80 1050 4659 4193 28.1 29.5 158 BXRC-65C4001-B-7x 6500 70 900 5046 4541 33.9 30.5 165 BXRC-65C4001-C-7x 6500 70 1170 6559 5903 33.9 39.7 165 BXRC-65C4001-D-7x 6500 70 1050 4905 4415 28.1 29.5 166 BXRC-65E4001-B-7x 6500 80 900 4848 4364 33.9 30.5 159 BXRC-65E4001-C-7x 6500 80 1170 6303 5673 33.9 39.7 159 BXRC-65E4001-D-7x 6500 80 1050 4714 4242 28.1 29.5 160 Notes for Table 3: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ±3 tolerance for all CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance.
European Product Registry for Energy Labeling The European Product Registry for Energy Labeling (EPREL) is defined in the EU Regulation 2017/1369 to provide import- ant energy efficiency information to consumers. Together with Energy Labeling Regulation ELR (EU) 2019/2015 which was amended by regulation (EU) 2021/340 for energy labelling of light sources, manufacturers are required to declare an ener- gy class based on key technical specifications from each of their product and register it in an open data base managed by EPREL It is now a legal requirement for a vendor of light sources to upload information about their products into the EPREL database before placing these products on the market in the EU. Table 4 below provides a list of part numbers that are in compliance with ELR and are currently listed in the EPREL data- base. At Bridgelux, we are fully committed to supplying products that are compliant with pertinent laws, rules, and obligation imposed by relevant government bodies including the European Energy Labeling regulation. Customers can use these products with full confidence for any projects that fall under the ELR. Table 4: Part numbers registered in European Product Registry for Energy Labeling PART NUMBER1 CCT (K) CRI Current2 (mA) Vf (V) Useful flux3 (Φuse) at 85C (lm) Pow- er (W) Efficacy (lm/W) Energy efficiency class4 Regis- tration No URL to Product Information Sheet in EPREL Database Notes for Table 4: 1. All device listed here must be disposed as e-waste upon its end of life according to local country guideline in each country. 2. For information on performance values at alternative drive conditions. please refer to the Product Selection Guide, Absolute Maximum Rating Table and Performance Curves in this data sheet. 3. For a definition of useful luminous flux (ΦΦuse), please see the ELR regulations at https:/ /tinyurl.com/4b6zvt4m. 4. EPREL requires an arrow symbol containing the letter of the energy efficiency class to be displayed. on technical promotional material. Refer to this energy efficiency class column for specific energy efficiency class on each part number.
European Product Registry for Energy Labeling Table 4: Part numbers registered in European Product Registry for Energy Labeling (Continued) PART NUMBER1 CCT (K) CRI Current2 (mA) Vf (V) Useful flux3 (Φuse) at 85C (lm) Pow- er (W) Efficacy (lm/W) Energy efficiency class4 Regis- tration No URL to Product Information Sheet in EPREL Database Notes for Table 4: 1. All device listed here must be disposed as e-waste upon its end of life according to local country guideline in each country. 2. For information on performance values at alternative drive conditions. please refer to the Product Selection Guide, Absolute Maximum Rating Table and Performance Curves in this data sheet. 3. For a definition of useful luminous flux (ΦΦuse), please see the ELR regulations at https:/ /tinyurl.com/4b6zvt4m. 4. EPREL requires an arrow symbol containing the letter of the energy efficiency class to be displayed. on technical promotional material. Refer to this energy efficiency class column for specific energy efficiency class on each part number.
European Product Registry for Energy Labeling Table 4: Part numbers registered in European Product Registry for Energy Labeling (Continued) PART NUMBER1 CCT (K) CRI Current2 (mA) Vf (V) Useful flux3 (Φuse) at 85C (lm) Pow- er (W) Efficacy (lm/W) Energy efficiency class4 Regis- tration No URL to Product Information Sheet in EPREL Database Notes for Table 4: 1. All device listed here must be disposed as e-waste upon its end of life according to local country guideline in each country. 2. For information on performance values at alternative drive conditions. please refer to the Product Selection Guide, Absolute Maximum Rating Table and Performance Curves in this data sheet. 3. For a definition of useful luminous flux (ΦΦuse), please see the ELR regulations at https:/ /tinyurl.com/4b6zvt4m. 4. EPREL requires an arrow symbol containing the letter of the energy efficiency class to be displayed. on technical promotional material. Refer to this energy efficiency class column for specific energy efficiency class on each part number.
Performance at Commonly Used Drive Currents Vero LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. Vero may also be driven at other drive currents dependent on specific application design requirements. The performance at any drive current can be derived from the current vs. voltage characteristics shown in Figures 1, 2 & 3 and the flux vs. current characteristics shown in Figures 4, 5 & 6. The performance at commonly used drive currents is summarized in Table 5. Table 5: Product Performance at Commonly Used Drive Currents Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-17E4000-B-7x 80 450 33.2 14.9 1547 1390 104 600 34.0 20.4 2029 1820 99 900 34.8 31.3 2881 2593 92 1350 35.6 48.1 4286 3776 89 1800 36.1 65.1 5515 4794 85 BXRC-17E4000-C-7x 80 585 33.2 19.4 1946 1748 100 780 34.0 26.5 2552 2289 96 1170 34.8 40.7 3624 3261 89 1755 35.6 62.5 5390 4749 86 2340 36.1 84.6 6935 6029 82 BXRC-17E4000-D-7x 80 525 27.7 14.6 1455 1307 100 700 28.2 19.8 1909 1712 97 1050 29.0 30.5 2710 2439 89 1575 30.4 47.9 4031 3551 84 2100 31.5 66.2 5187 4509 78 BXRC-20B4001-C-7x 65 585 33.2 19.4 3432 3084 177 780 34.0 26.5 4502 4038 170 1170 34.8 40.7 6392 5753 157 1755 35.6 62.5 9507 8377 152 2340 36.1 84.6 12234 10635 145 BXRC-20B4001-D-7x 65 525 27.7 14.6 2567 2306 176 700 28.2 19.8 3367 3020 170 1050 29.0 30.5 4781 4303 157 1575 30.4 47.9 7110 6265 148 2100 31.5 66.2 9150 7954 138 BXRC-25E4000-B-7x 80 450 33.2 14.9 2573 2312 172 600 34.0 20.4 3375 3027 165 900 34.8 31.3 4792 4313 153 1350 35.6 48.1 7127 6280 148 1800 36.1 65.1 9171 7972 141 BXRC-25E4000-C-7x 80 585 33.2 19.4 3345 3005 172 780 34.0 26.5 4387 3935 165 1170 34.8 40.7 6230 i102 153 1755 35.6 62.5 9265 8164 148 2340 36.1 84.6 11923 10364 141 BXRC-25E4000-D-7x 80 525 27.7 14.6 2501 2248 172 700 28.2 19.8 3281 2943 166 1050 29.0 30.5 4659 4193 153 1575 30.4 47.9 6929 6105 145 2100 31.5 66.2 8917 7751 135 Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-27E4000-B-7x 80 450 33.2 14.9 2691 2418 180 600 34.0 20.4 3529 3166 173 900 34.8 31.3 5011 4510 160 1350 35.6 48.1 7453 6567 155 1800 36.1 65.1 9591 8337 147 BXRC-27E4000-C-7x 80 585 33.2 19.4 3404 3221 175 780 34.0 26.5 4460 4133 168 1170 34.8 40.7 6515 5863 160 1755 35.6 62.5 9372 8249 150 2340 36.1 84.6 12021 10361 142 BXRC-27E4000-D-7x 80 525 27.7 14.6 2595 2409 178 700 28.2 19.8 3375 3093 171 1050 29.0 30.5 4872 4385 160 1575 30.4 47.9 6959 6154 145 2100 31.5 66.2 8859 7704 134 BXRC-27G40H0-B-7x 90 450 33.2 14.9 2304 2070 154 600 34.0 20.4 3022 2711 148 900 34.8 31.3 4291 3862 137 1350 35.6 48.1 6382 5623 133 1800 36.1 65.1 8212 7139 126 BXRC-27G40H0-C-7x 90 585 33.2 19.4 2914 2758 150 780 34.0 26.5 3819 3539 144 1170 34.8 40.7 5578 5020 137 1755 35.6 62.5 8025 7063 128 2340 36.1 84.6 10293 8872 122 BXRC-27G40H0-D-7x 90 525 27.7 14.6 2222 2063 153 700 28.2 19.8 2890 2648 146 1050 29.0 30.5 4172 3754 137 1575 30.4 47.9 5959 5269 124 2100 31.5 66.2 7585 6596 115 BXRC-27G4000-B-7x 90 450 33.2 14.9 2220 1995 149 600 34.0 20.4 2912 2612 143 900 34.8 31.3 4134 3721 132 1350 35.6 48.1 6149 5418 128 1800 36.1 65.1 7913 6878 122 BXRC-27G4000-C-7x 90 585 33.2 19.4 2808 2658 145 780 34.0 26.5 3680 3410 139 1170 34.8 40.7 5375 4837 132 1755 35.6 62.5 7732 6805 124 2340 36.1 84.6 9918 8548 117 BXRC-27G4000-D-7x 90 525 27.7 14.6 2141 1987 147 700 28.2 19.8 2784 2552 141 1050 29.0 30.5 4019 3617 132 1575 30.4 47.9 5741 5077 120 2100 31.5 66.2 7308 6355 110 Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-27H4000-B-7x 97 450 33.2 14.9 1967 1812 132 600 34.0 20.4 2581 2326 126 900 34.8 31.3 3664 3298 117 1350 35.6 48.1 5450 4628 113 1800 36.1 65.1 7013 5794 108 BXRC-27H4000-C-7x 97 585 33.2 19.4 2489 2355 128 780 34.0 26.5 3262 3024 123 1170 34.8 40.7 4764 4287 117 1755 35.6 62.5 6853 6017 110 2340 36.1 84.6 8791 7532 104 BXRC-27H4000-D-7x 97 525 27.7 14.6 1898 1762 130 700 28.2 19.8 2468 2262 125 1050 29.0 30.5 3563 3206 117 1575 30.4 47.9 5089 4500 106 2100 31.5 66.2 6478 5633 98 BXRC-30C4001-B-7x 70 450 33.2 14.9 2993 2757 200 600 34.0 20.4 3926 3539 192 900 34.8 31.3 5575 5017 178 1350 35.6 48.1 8292 7041 172 1800 36.1 65.1 10670 8815 164 BXRC-30C4001-C-7x 70 585 33.2 19.4 3787 3584 195 780 34.0 26.5 4962 4601 187 1170 34.8 40.7 7247 6523 178 1755 35.6 62.5 10426 9154 167 2340 36.1 84.6 13374 11460 158 BXRC-30C4001-D-7x 70 525 27.7 14.6 2887 2680 198 700 28.2 19.8 3755 3441 190 1050 29.0 30.5 5420 4878 178 1575 30.4 47.9 7742 6846 162 2100 31.5 66.2 9855 8570 149 BXRC-30E4000-B-7x 80 450 33.2 14.9 2859 2569 191 600 34.0 20.4 3750 3363 184 900 34.8 31.3 5324 4792 170 1350 35.6 48.1 7919 6977 165 1800 36.1 65.1 10190 8858 157 BXRC-30E4000-C-7x 80 585 33.2 19.4 3617 3423 186 780 34.0 26.5 4739 4392 179 1170 34.8 40.7 6922 6230 170 1755 35.6 62.5 9958 8764 159 2340 36.1 84.6 12773 11009 151 BXRC-30E4000-D-7x 80 525 27.7 14.6 2758 2560 189 700 28.2 19.8 3586 3286 181 1050 29.0 30.5 5177 4659 170 1575 30.4 47.9 7394 6538 154 2100 31.5 66.2 9412 8185 142 Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. Performance at Commonly Used Drive Currents
Performance at Commonly Used Drive Currents Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-30G40H0-B-7x 90 450 33.2 14.9 2321 2085 155 600 34.0 20.4 3044 2730 149 900 34.8 31.3 4322 3890 138 1350 35.6 48.1 6428 5664 134 1800 36.1 65.1 8272 7191 127 BXRC-30G40H0-C-7x 90 585 33.2 19.4 2936 2778 151 780 34.0 26.5 3847 3565 145 1170 34.8 40.7 5619 5057 138 1755 35.6 62.5 8083 7115 129 2340 36.1 84.6 10368 8937 123 BXRC-30G40H0-D-7x 90 525 27.7 14.6 2238 2078 154 700 28.2 19.8 2911 2667 147 1050 29.0 30.5 4202 3782 138 1575 30.4 47.9 6002 5307 125 2100 31.5 66.2 7641 6644 115 BXRC-30G4000-B-7x 90 450 33.2 14.9 2421 2176 162 600 34.0 20.4 3176 2849 156 900 34.8 31.3 4510 4059 144 1350 35.6 48.1 6708 5910 139 1800 36.1 65.1 8632 7503 133 BXRC-30G4000-C-7x 90 585 33.2 19.4 3063 2899 158 780 34.0 26.5 4014 3720 151 1170 34.8 40.7 5863 5277 144 1755 35.6 62.5 8435 7424 135 2340 36.1 84.6 10819 9325 128 BXRC-30G4000-D-7x 90 525 27.7 14.6 2336 2168 160 700 28.2 19.8 3037 2783 154 1050 29.0 30.5 4385 3946 144 1575 30.4 47.9 6263 5538 131 2100 31.5 66.2 7973 6933 120 BXRC-30G400C-B-7x 90 450 33.2 14.9 2236 2010 150 600 34.0 20.4 2934 2631 144 900 34.8 31.3 4166 3749 133 1350 35.6 48.1 6195 5459 129 1800 36.1 65.1 7972 6930 123 BXRC-30G400C-D-7x 90 525 27.7 14.6 2157 2002 148 700 28.2 19.8 2805 2571 142 1050 29.0 30.5 4050 3645 133 1575 30.4 47.9 5785 5115 121 2100 31.5 66.2 7364 6404 111 BXRC-30H4000-B-7x 97 450 33.2 14.9 2102 1936 141 600 34.0 20.4 2757 2485 135 900 34.8 31.3 3915 3524 125 1350 35.6 48.1 5823 4945 121 1800 36.1 65.1 7493 6190 115 Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-30H4000-C-7x 97 585 33.2 19.4 2659 2517 137 780 34.0 26.5 3485 3231 131 1170 34.8 40.7 5090 4581 125 1755 35.6 62.5 7322 6428 117 2340 36.1 84.6 9392 8048 111 BXRC-30H4000-D-7x 97 525 27.7 14.6 2028 1882 139 700 28.2 19.8 2637 2416 133 1050 29.0 30.5 3806 3426 125 1575 30.4 47.9 5437 4807 113 2100 31.5 66.2 6921 6018 105 BXRC-30A4001-B-7x 93 450 33.3 15.0 2085 1874 139 600 33.9 20.4 2735 2453 134 900 35.0 31.2 3884 3495 124 1350 36.7 49.5 5776 5089 117 1800 38.0 68.4 7433 6461 109 BXRC-30A4001-C-7x 93 585 33.4 19.5 2638 2496 135 780 34.0 26.5 3457 3203 130 1170 35.0 40.6 5049 4544 124 1755 36.8 64.5 7263 6393 113 2340 38.1 89.3 9317 8030 104 BXRC-30A4001-D-7x 93 525 27.7 14.6 2011 1867 138 700 28.2 19.8 2615 2397 132 1050 29.0 30.4 3776 3398 124 1575 30.4 47.9 5393 4769 113 2100 31.5 66.2 6866 5970 104 BXRC-35E4000-B-7x 80 450 33.2 14.9 2926 2629 196 600 34.0 20.4 3838 3443 188 900 34.8 31.3 5450 4905 174 1350 35.6 48.1 8105 7142 168 1800 36.1 65.1 10430 9067 160 BXRC-35E4000-C-7x 80 585 33.2 19.4 3702 3503 191 780 34.0 26.5 4851 4495 183 1170 34.8 40.7 7085 6376 174 1755 35.6 62.5 10192 8970 163 2340 36.1 84.6 13073 11268 155 BXRC-35E4000-D-7x 80 525 27.7 14.6 2822 2620 194 700 28.2 19.8 3670 3363 186 1050 29.0 30.5 5298 4768 174 1575 30.4 47.9 7568 6692 158 2100 31.5 66.2 9634 8378 145 BXRC-35G4000-B-7x 90 450 33.2 14.9 2405 2161 161 600 34.0 20.4 3154 2829 155 900 34.8 31.3 4479 4031 143 1350 35.6 48.1 6661 5869 138 1800 36.1 65.1 8572 7451 132 Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-35G4000-C-7x 90 585 33.2 19.4 3042 2879 157 780 34.0 26.5 3986 3694 150 1170 34.8 40.7 5822 5240 143 1755 35.6 62.5 8376 7372 134 2340 36.1 84.6 10744 9260 127 BXRC-35G4000-D-7x 90 525 27.7 14.6 2320 2153 159 700 28.2 19.8 3016 2764 153 1050 29.0 30.5 4354 3919 143 1575 30.4 47.9 6220 5500 130 2100 31.5 66.2 7918 6885 120 BXRC-35A4001-B-7x 80 450 33.2 14.9 2220 1995 149 600 34.0 20.4 2912 2612 143 900 34.8 31.3 4134 3721 132 1350 35.6 48.1 6149 5418 128 1800 36.1 65.1 7913 6878 122 BXRC-35A4001-C-7x 80 585 33.2 19.4 2808 2658 145 780 34.0 26.5 3680 3410 139 1170 34.8 40.7 5375 4837 132 1755 35.6 62.5 7732 6805 124 2340 36.1 84.6 9918 8548 117 BXRC-35A4001-D-7x 80 525 27.7 14.6 2141 1987 147 700 28.2 19.8 2784 2552 141 1050 29.0 30.5 4019 3617 132 1575 30.4 47.9 5741 5077 120 2100 31.5 66.2 7308 6355 110 BXRC-40C4001-B-7x 80 450 33.2 14.9 3077 2765 206 600 34.0 20.4 4037 3621 198 900 34.8 31.3 5732 5158 183 1350 35.6 48.1 8525 7511 177 1800 36.1 65.1 10970 9536 169 BXRC-40C4001-C-7x 80 585 33.2 19.4 3893 3684 200 780 34.0 26.5 5102 4728 192 1170 34.8 40.7 7451 6706 183 1755 35.6 62.5 10719 9434 171 2340 36.1 84.6 13750 11851 163 BXRC-40C4001-D-7x 80 525 27.7 14.6 2968 2755 204 700 28.2 19.8 3860 3537 195 1050 29.0 30.5 5572 5015 183 1575 30.4 47.9 7959 7038 166 2100 31.5 66.2 10132 8811 153 BXRC-40E4000-B-7x 80 450 33.2 14.9 2943 2644 197 600 34.0 20.4 3860 3462 189 900 34.8 31.3 5481 4933 175 1350 35.6 48.1 8152 7183 169 1800 36.1 65.1 10490 9119 161 Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-40E4000-C-7x 80 585 33.2 19.4 3723 3523 192 780 34.0 26.5 4879 4521 184 1170 34.8 40.7 7125 6413 175 1755 35.6 62.5 10250 9022 164 2340 36.1 84.6 13148 11333 155 BXRC-40E4000-D-7x 80 525 27.7 14.6 2839 2635 195 700 28.2 19.8 3691 3383 187 1050 29.0 30.5 5329 4796 175 1575 30.4 47.9 7611 6730 159 2100 31.5 66.2 9689 8426 146 BXRC-40G4000-B-7x 90 450 33.2 14.9 2455 2206 164 600 34.0 20.4 3221 2889 158 900 34.8 31.3 4573 4115 146 1350 35.6 48.1 6801 5992 141 1800 36.1 65.1 8752 7608 135 BXRC-40G4000-C-7x 90 585 33.2 19.4 3106 2939 160 780 34.0 26.5 4070 3772 153 1170 34.8 40.7 5945 5350 146 1755 35.6 62.5 8552 7527 137 2340 36.1 84.6 10970 9455 130 BXRC-40G4000-D-7x 90 525 27.7 14.6 2368 2198 163 700 28.2 19.8 3080 2822 156 1050 29.0 30.5 4446 4001 146 1575 30.4 47.9 6350 5615 132 2100 31.5 66.2 8084 7030 122 BXRC-40H4000-B-7x 97 450 33.2 14.9 2220 1995 149 600 34.0 20.4 2912 2612 143 900 34.8 31.3 4134 3721 132 1350 35.6 48.1 6149 5418 128 1800 36.1 65.1 7913 6878 122 BXRC-40H4000-C-7x 97 585 33.2 19.4 2808 2658 145 780 34.0 26.5 3680 3410 139 1170 34.8 40.7 5375 4837 132 1755 35.6 62.5 7732 6805 124 2340 36.1 84.6 9918 8548 117 BXRC-40H4000-D-7x 97 525 27.7 14.6 2141 1987 147 700 28.2 19.8 2784 2552 141 1050 29.0 30.5 4019 3617 132 1575 30.4 47.9 5741 5077 120 2100 31.5 66.2 7308 6355 110 BXRC-40A4001-B-7x 80 450 33.2 14.9 2405 2161 161 600 34.0 20.4 3154 2829 155 900 34.8 31.3 4479 4031 143 1350 35.6 48.1 6661 5869 138 1800 36.1 65.1 8572 7451 132 Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-40A4001-C-7x 80 585 33.2 19.4 3042 2879 157 780 34.0 26.5 3986 3694 150 1170 34.8 40.7 5822 5240 143 1755 35.6 62.5 8376 7372 134 2340 36.1 84.6 10744 9260 127 BXRC-40A4001-D-7x 80 525 27.7 14.6 2320 2153 159 700 28.2 19.8 3016 2764 153 1050 29.0 30.5 4354 3919 143 1575 30.4 47.9 6220 5500 130 2100 31.5 66.2 7918 6885 120 BXRC-50C4001-B-7x 70 450 33.2 14.9 3094 2780 207 600 34.0 20.4 4059 3640 199 900 34.8 31.3 5763 5187 184 1350 35.6 48.1 8571 7552 178 1800 36.1 65.1 11030 9588 170 BXRC-50C4001-C-7x 70 585 33.2 19.4 3914 3704 201 780 34.0 26.5 5129 4753 193 1170 34.8 40.7 7492 6743 184 1755 35.6 62.5 10778 9486 172 2340 36.1 84.6 13825 11915 163 BXRC-50C4001-D-7x 70 525 27.7 14.6 2985 2770 205 700 28.2 19.8 3881 3557 196 1050 29.0 30.5 5603 5043 184 1575 30.4 47.9 8003 7077 167 2100 31.5 66.2 10188 8859 154 BXRC-50E4001-B-7x 80 450 33.2 14.9 2976 2675 199 600 34.0 20.4 3904 3502 191 900 34.8 31.3 5544 4989 177 1350 35.6 48.1 8245 7265 171 1800 36.1 65.1 10610 9223 163 BXRC-50E4001-C-7x 80 585 33.2 19.4 3765 3563 194 780 34.0 26.5 4934 4573 186 1170 34.8 40.7 7207 6486 177 1755 35.6 62.5 10368 9125 166 2340 36.1 84.6 13299 11462 157 BXRC-50E4001-D-7x 80 525 27.7 14.6 2871 2665 197 700 28.2 19.8 3733 3421 189 1050 29.0 30.5 5390 4851 177 1575 30.4 47.9 7698 6807 161 2100 31.5 66.2 9800 8522 148 BXRC-50G4001-B-7x 90 450 33.2 14.9 2573 2312 172 600 34.0 20.4 3375 3027 165 900 34.8 31.3 4792 4313 153 1350 35.6 48.1 7127 6280 148 1800 36.1 65.1 9171 7972 141 Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-50G4001-C-7x 90 585 33.2 19.4 3092 2926 168 780 34.0 26.5 4052 3755 161 1170 34.8 40.7 5919 5327 153 1755 35.6 62.5 8514 7494 143 2340 36.1 84.6 10921 9413 136 BXRC-50G4001-D-7x 90 525 27.7 14.6 2482 2304 170 700 28.2 19.8 3227 2957 163 1050 29.0 30.5 4659 4193 153 1575 30.4 47.9 6654 5884 139 2100 31.5 66.2 8471 7367 128 BXRC-56G4000-B-7x 90 450 33.2 14.9 2569 2385 172 600 34.0 20.4 3341 3062 164 900 34.8 31.3 4823 4341 154 1350 35.6 48.1 6889 6092 143 1800 36.1 65.1 8770 7627 135 BXRC-56G4000-C-7x 90 585 33.2 19.4 3340 3100 172 780 34.0 26.5 4343 3980 164 1170 34.8 40.7 6270 5643 154 1755 35.6 62.5 8956 7920 143 2340 36.1 84.6 11401 9915 135 BXRC-56G400x-D-7x 90 525 27.7 14.6 2498 2319 172 700 28.2 19.8 3248 2977 164 1050 29.0 30.5 4689 4220 154 1575 30.4 47.9 6698 5923 140 2100 31.5 66.2 8527 7415 129 BXRC-56H4000-D-7x 97 525 27.7 14.6 2255 2093 155 700 28.2 19.8 2932 2687 148 1050 29.0 30.5 4233 3809 139 1575 30.4 47.9 6046 5346 126 2100 31.5 66.2 7696 6693 116 BXRC-57C4001-B-7x 70 450 33.2 14.9 3010 2705 201 600 34.0 20.4 3949 3541 194 900 34.8 31.3 5606 5046 179 1350 35.6 48.1 8338 7347 173 1800 36.1 65.1 10730 9327 165 BXRC-57C4001-C-7x 70 585 33.2 19.4 3808 3604 196 780 34.0 26.5 4990 4624 188 1170 34.8 40.7 7288 6559 179 1755 35.6 62.5 10485 9228 168 2340 36.1 84.6 13449 11592 159 BXRC-57C4001-D-7x 70 525 27.7 14.6 2904 2695 199 700 28.2 19.8 3776 3460 191 1050 29.0 30.5 5451 4905 179 1575 30.4 47.9 7785 6884 162 2100 31.5 66.2 9911 8618 150 Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. Table 5: Product Performance at Commonly Used Drive Currents (Continued)
Performance at Commonly Used Drive Currents Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-57E4001-B-7x 80 450 33.2 14.9 2859 2569 191 600 34.0 20.4 3750 3363 184 900 34.8 31.3 5324 4792 170 1350 35.6 48.1 7919 6977 165 1800 36.1 65.1 10190 8858 157 BXRC-57E4001-C-7x 80 585 33.2 19.4 3617 3423 186 780 34.0 26.5 4739 4392 179 1170 34.8 40.7 6922 6230 170 1755 35.6 62.5 9958 8764 159 2340 36.1 84.6 12773 11009 151 BXRC-57E4001-D-7x 80 525 27.7 14.6 2758 2560 189 700 28.2 19.8 3586 3286 181 1050 29.0 30.5 5177 4659 170 1575 30.4 47.9 7394 6538 154 2100 31.5 66.2 9412 8185 142 BXRC-65C4001-B-7x 70 450 33.2 14.9 3010 2705 201 600 34.0 20.4 3949 3541 194 900 34.8 31.3 5606 5046 179 1350 35.6 48.1 8338 7347 173 1800 36.1 65.1 10730 9327 165 BXRC-65C4001-C-7x 70 585 33.2 19.4 3808 3604 196 780 34.0 26.5 4990 4624 188 1170 34.8 40.7 7288 6559 179 1755 35.6 62.5 10485 9228 168 2340 36.1 84.6 13449 11592 159 BXRC-65C4001-D-7x 70 525 27.7 14.6 2904 2695 199 700 28.2 19.8 3776 3460 191 1050 29.0 30.5 5451 4905 179 1575 30.4 47.9 7785 6884 162 2100 31.5 66.2 9911 8618 150 BXRC-65E4001-B-7x 80 450 33.2 14.9 2892 2599 194 600 34.0 20.4 3794 3403 186 900 34.8 31.3 5387 4848 172 1350 35.6 48.1 8012 7059 167 1800 36.1 65.1 10310 8962 158 BXRC-65E4001-C-7x 80 585 33.2 19.4 3659 3463 188 780 34.0 26.5 4795 4443 181 1170 34.8 40.7 7003 6303 172 1755 35.6 62.5 10075 8867 161 2340 36.1 84.6 12923 11138 153 BXRC-65E4001-D-7x 80 525 27.7 14.6 2790 2590 192 700 28.2 19.8 3628 3325 184 1050 29.0 30.5 5237 4714 172 1575 30.4 47.9 7481 6615 156 2100 31.5 66.2 9523 8281 144 Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Electrical Characteristics
Table 6: Electrical Characteristics Part Number Drive Current (mA) Forward Voltage Pulsed, Tc = 25ºC (V) 1, 2, 3, 8 Typical Coefficient of Forward Voltage4 ∆Vf/∆Tc (mV/ºC) Typical Thermal Resistance Junction to Case5,6 Rj-c (ºC/W) Driver Selection Voltages7 (V) Minimum Typical Maximum Vf Min. Hot Tc = 105ºC (V) Vf Max. Cold Tc = -40ºC (V) BXRC-xxx400x-B-7x BXRC-xxx400x-C-7x BXRC-xxx400x-D-7x Notes for Table 6: 1. Parts are tested in pulsed conditions, Tc = 25°C. Pulse width is 10ms. 2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance. 3. Bridgelux maintains a tester tolerance of ± 0.10V on forward voltage measurements. 4. Typical coefficient of forward voltage tolerance is ± 0.1mV for nominal current. 5. Thermal resistance values are based from test data of a 3000K 80 CRI product. 6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal interface material used during testing is not included in the thermal resistance value. 7. Vf min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design and selection over the operating range of the product. 8. This product has been designed and manufactured per IEC 62031:2018. This product has passed dielectric withstand voltage testing at 1160 V. The working voltage designated for the insulation is 80V d.c. The maximum allowable voltage across the array must be determined in the end product application.
Table 7: Eye Safety Risk Group (RG) Classifications Part Number Drive Current 5 (mA) CCT1,5 2700K/3000K 4000K2 5000K3 6500K4 BXRC-xxx400x-B-7x
900 RG1 RG1 RG1 RG1
1350 RG1 RG1 RG1 RG2
1800 RG1 RG1 RG2 RG2
1170 RG1 RG1 RG1 RG1
1755 RG1 RG1 RG2 RG2
2340 RG1 RG1 RG2 RG2
1050 RG1 RG1 RG1 RG1
1575 RG1 RG1 RG1 RG2
2100 RG1 RG1 RG2 RG2
Notes for Table 7: 1. Eye safety classification for the use of Bridgelux Vero Series LED arrays is in accordance with specification IEC/TR 62778: Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires. 2. For products classified as RG2 at 4000K, Ethr= 1847.5 lx. 3. For products classified as RG2 at 5000K Ethr= 1315.8 lx. 4. For products classified as RG2 at 6500K, Ethr= 1124.5 lx. 5. Please contact your Bridgelux sales representative for Ethr values at specific drive currents and CCTs not listed.
LED Junction Temperature (Tj) 150°C Storage Temperature -40°C to +105°C Operating Case Temperature1 (Tc) 105°C Soldering Temperature2 300°C or lower for a maximum of 6 seconds BXRC-xxx400x-B-7x BXRC-xxx400x-C-7x BXRC-xxx400x-D-7x Maximum Drive Current3 1800mA 2340mA 2100mA Maximum Peak Pulsed Drive Current4 2570mA 3340mA 3000mA Maximum Reverse Voltage5 -60V -60V -50V Notes for Table 8: 1. For IEC 62717 requirement, please consult your Bridgelux sales representative. 2. Refer to Bridgelux Application Note AN31: Assembly Considerations for Bridgelux Vero LED Arrays. 3. Arrays may be driven at higher currents however lumen maintenance may be reduced. 4. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed current specified. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures. 5. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating provided for reference only. Table 8: Maximum Ratings
Figure 24: Drawing for Vero 18 LED Array Notes for Figure 24: 1. Drawings are not to scale. 2. Drawing dimensions are in millimeters. 3. Unless otherwise specified, tolerances are ±0.1mm. 4. Mounting holes (2X) are for M2.5 screws. 5. Bridgelux recommends two tapped holes for mounting screws with 31.4 ± 0.10mm center-to-center spacing. 6. Screws with flat shoulders (pan, dome, button, round, truss, mushroom) provide optimal torque control. Do NOT use flat, countersink, or raised head screws. 7. Solder pads and connector port are labeled “+” and “-“ to denote positive and negative, respectively. 8. It is not necessary to provide electrical connections to both the solder pads and the connector port. Either set may be used depending on application specific design requirements. 9. Refer to Application Notes AN30 and AN31 for product handling, mounting and heat sink recommendations. 10. The optical center of the LED Array is nominally defined by the mechanical center of the array to a tolerance of ± 0.2mm. 11. Bridgelux maintains a flatness of 0.10mm across the mounting surface of the array.
Figure 25: Warm and Neutral White Test Bins in xy Color Space Figure 26: Cool White Test Bins in xy Color Space Color Binning Information Bin Code 1750K 2000K 2500K 2700K 3000K1 3500K1 4000K1 ANSI Bin (for reference only) - - - (2580K - 2870K) (2870K - 3220K) (3220K - 3710K) (3710K - 4260K) 73 (3 SDCM) - - - (2651K - 2794K) (2968K - 3136K) (3369K - 3586K) (3851K - 4130K) 72 (2 SDCM) - - - (2674K - 2769K) (2995K - 3107K) (3404K - 3548K) (3895K - 4081K) Table 9: Warm and Neutral White xy Bin Coordinates and Associated Typical CCT Bin Code 5000K 5600K 5700K 6500K ANSI Bin (for reference only) (4745K - 5311K) (5310K - 6020K) (5312K - 6022K) (6022K - 7042K) 74 (4 SDCM) (4801K - 5282K) (5475K - 5830K) (5395K- 5970K) (6200K - 6910K) 73 (3 SDCM) (4835K - 5215K) (5490K - 5820K) (5460K- 5891K) (6279K -6811K) Table 10: Cool White xy Bin Coordinates and Associated Typical CCT (product is hot targeted to Tc = 85°C) Note: Pulsed Test Conditions, Tc = 25°C Note: Pulsed Test Conditions, Tc = 25°C Note: Pulsed Test Conditions, Tc = 25°C Notes for Table 10: 1. Select configurations with a CCT of 5600K are available with center point targets at Tc = 85°C or Tc = 25°C. 2. Bridgelux maintains a tolerance of +/- 0.007 on x and y color coordinates in the CIE 1931 color Space. Notes for Table 9: 1. Color Binning information excludes Decor Series Class A products. Please contact your Bridgelux Sales Representative for more information. 2. Center Point for Decor Series Showcase. 3. Bridgelux maintains a tolerance of +/- 0.007 on x and y color coordinates in the CIE 1931 color Space. 0.34 0.36 0.38 0.4 0.42 0.44 Y X
3 SDCM
4 SDCM
0.3 0.31 0.32 0.33 0.34 0.35 0.36 0.37 0.38 0.39 Y X
Figure 27: Drawing for Vero 18 Packaging Tray Notes for Figure 27: 1. Dimensions are in millimeters. 2. Drawings are not to scale.
Bridgelux has developed a comprehensive set of application notes and design resources to assist customers in successfully designing with the Vero product family of LED array products. For all available application notes visit www.bridgelux.com. Optical Source Models Optical source models and ray set files are available for all Bridgelux products. For a list of available formats, visit www.bridgelux.com. MINOR PRODUCT CHANGE POLICY The rigorous qualification testing on products offered by Bridgelux provides performance assurance. Slight cosmetic changes that do not affect form, fit, or function may occur as Bridgelux continues product optimization. CAUTION: CHEMICAL EXPOSURE HAZARD Exposure to some chemicals commonly used in luminaire manufacturing and assembly can cause damage to the LED array. Please consult Bridgelux CAUTION: RISK OF BURN Do not touch the Vero LED array during operation. Allow the array to cool for a sufficient period of time before handling. The Vero LED array may reach elevated temperatures such that could burn skin when touched. 3D CAD Models Three dimensional CAD models depicting the product outline of all Bridgelux Vero LED arrays are available in both IGS and STEP formats. Please contact your Bridgelux sales representative for assistance. LM80 LM80 testing has been completed and the LM80 report is now available. Please contact your Bridgelux sales rep- resentative for LM-80 report. CAUTION CONTACT WITH LIGHT EMITTING SURFACE (LES) Avoid any contact with the LES. Do not touch the LES of the LED array or apply stress to the LES (yellow phosphor resin area). Contact may cause damage to the LED array. Optics and reflectors must not be mounted in contact with the LES (yellow phosphor resin area). Optical devices may be mounted on the top surface of the plastic housing of the Vero LED array. Use the mechanical features of the LED array housing, edges and/or mounting holes to locate and secure optical devices as needed. STANDARD TEST CONDITIONS Unless otherwise stated, array testing is performed at the nominal drive current.
About Bridgelux: Bridging Light and Life™ © 2023 Bridgelux, Inc. All rights reserved. Product specifications are subject to change without notice. Bridgelux, the Bridgelux stylized logo design, Vero, V Series and V Series HD are registered trademarks, and Decor Series is a trademark of Bridgelux, Inc. All other trademarks are the property of their respective owners. Bridgelux Gen 7 Vero 18 Array Series Product Data Sheet DS92 Rev. S (08/2023)
46410 Fremont Boulevard
Fremont, CA 94538 U.S.A. Tel (925) 583-8400 www.bridgelux.com At Bridgelux, we help companies, industries and people experience the power and possibility of light. Since 2002, we’ve designed LED solutions that are high performing, energy efficient, cost effective and easy to integrate. Our focus is on light’s impact on human behavior, deliver- ing products that create better environments, experiences and returns—both experiential and financial. And our patented technology drives new platforms for commercial and industrial luminaires. For more information about the company, please visit bridgelux.com twitter.com/Bridgelux facebook.com/Bridgelux youtube.com/user/Bridgelux linkedin.com/company/bridgelux-inc-_2 WeChat ID: BridgeluxInChina