©2020 Advanced Energy Industries, Inc. ARTESYN DS800SL SERIES
800 Watts Bulk Front End
Total Output Power: 800 Watts +5.0 Vdc Standby DATA SHEETAdvanced Energy's Artesyn DS800SL series bulk front end AC-DC power supply accepts a wide range 90–264 Vac input and provides a main 12 V output plus a 5 V standby output. Rated at 800 watts it is an 80 Plus Gold supply with a high half-load efficiency of 92%. Housed in a slimline 1U high, 2.1 inch wide rack-mounting package, the power supply is primarily designed for ‘always-on’ enterprise servers and similar space-constrained applications. This series comes in two airflow versions – dc-connector to ac-connector and vice versa. SPECIAL FEATURES 800 W output power 19.05 W/cu-in 1U X 54.5 mm form factor (slimline) N + 1 redundant Hot-swap Internal OR’ing 5.0 V housekeeping High efficiency 92% @ 200 Vac, 50% load (Climate Savers Gold) Variable speed “smart fans” EMI Class B Available in two airflow directions SAFETY UL/cUL 60950 -1 CSA 60950-1 VDE 60950-1 China CCC CB Scheme Report/Cert
2 advancedenergy.com DS800SL ELECTRICAL SPECIFICATIONS Input Input ra nge (operating) 90 - 264 Vac Input range (nominal) 115 / 230 Vac Frequency 47 - 63 Hz Inrush current ≤ 40 A peak Either hot or cold start Power factor 0.99 typical Meets EN61000-3-2 Harmonics Meets IEC 1000-3-2 requirements Input current 10.0 A RMS max input current At 100 Vac Holdup time 10 ms minimum for main O/P At full rated load Undervoltage lockout 85 ± 3.0 Vac 80 ± 3.0 Vac Turn-on voltage Turn-off voltage Overvoltage lockout N/A Leakage current < 1.0 mA At 264 Vac On/Off power switch N/A Power line transient MOV directly after the fuse Ef/f_iciency Curve 800 W DS Slim 80.0% 82.0% 84.0% 86.0% 88.0% 90.0% 92.0% Output Power [W] Ef/f_iciency
230 Vac, 50 Hz
115 Vac, 60 Hz
Ambient Temperature (degC) DS800SL-3-001 Power Derating 100Vac 110Vac 230Vac
advancedenergy.com 3 DS800SL ELECTRICAL SPECIFICATIONS (CONTINUED) Input Output rating 12 V @ 66.7 A; 800 W
5.0 Vsb @ 4 A; 20 W
Setpoint 12.0 V Total regulation range 12 V ± 1%
5.0 Vsb ± 3%
Line/load/transient when measured at output connector Rated load 800 W maximum No derating over operating temp range for forward air Minimum load 12 V @ 0.5 A 5.0 Vsb @ 0.0 A No load operation shall not damage the power supply Output noise (PARD) 120 mV Max P-P 100 mV Max P-P
12.0 V output
5.0 Vsb output
Measured with a 0.1 uF ceramic and 10 uF tantalum capacitor on any output; 20 Mhz Output voltage overshoot 600 mV; 12 V main 250 mV; 5.0 standby
1 A/uSec slew rate
Transient response +/-5% of regulation range 50% load step @ 1 A/us Step load valid between 10% to 100% of output rating Recovery time to within 1% of set point at onset of transient Max units in parallel Up to 6 Short circuit protection >130% of rated output Output to return Remote sense Compensation up to 100 mV Output isolation Standard per Safety Requirements Forced load sharing To within 10% of all shared outputs Digital sharing control Overload protection (OCP) 120% to 130% 120% to 170%
12 V output
Overvoltage protection (OVP) 110% to 120% 110% to 125% Overtemperature protection 10 - 15 ˚C above safe operating area Both PFC and output converter monitored
4 advancedenergy.com DS800SL OUTPUTS - ALL MODELS TPWOK_Off_ AC Input Main Vout Timing Diagram TAC_On_Delay TVout_Holdup TPWOK_On AC Input ON / OFF Cycle AC_OK PS_ON
5.0 Vsb Vout
Tsb_On TSB_Vout TPWOK_On TPWOK_Off_ TACOK_Delay TPSON_On_Delay TPSON_PWOK TPWOK_Off AC On AC On TPWOK_Holdup Tsb_on_delay
advancedenergy.com 5 DS800SL OUTPUTS - ALL MODELS (CONTINUED) Turn On/Off Timing Item Description Min Max Units Tvout_rise +12 Output rise time 5 300 mSec Tvout_rise 5.0 Vsb output rise time 1 50 mSec Tsb_on_delay Delay from AC being applied to 5.0 Vsb being within regulation. 2000 mSec Tac_on_delay Delay from AC being applied to all output voltages being within regulation. 4000 mSec Tvout_holdup Time all output voltages, including 5.0 Vsb, stay within regulation after loss of AC. 12 mSec Tpwok_holdup Delay from loss of AC to de-assertion of PWOK. 5 mSec Tpson_on_delay Delay from PSON# active to output voltages within regulation limits. 5 200 mSec Tpson_pwok Delay from PSON# de-active to PWOK being de-asserted. 50 mSec Tacok_delay Delay from loss of AC input to de-assertion of ACOK#. 5 12 mSec Tpwok_on Delay from output voltages within regulation limits to PWOK asserted at turn on. 100 1000 mSec Tpwok_off Delay from PWOK de-asserted to 12 Vdc or 5.0 Vsb dropping out of regulation limits. 1 1000 mSec Tpwok_low Duration of PWOK being in the de-asserted state during an off/on cycle using AC or the PSON# signal. 100 mSec Tsb_vout Delay from 5.0 Vsb being in regulation to 12 Vdc being in regulation at AC turn on. 50 1000 mSec PSON # The PSON# signal is required to remotely turn on/off the power supply. PSON# is an active low signal that turns on the +12 Vdc power rail. When this signal is not pulled low by the system, or left open, the +12 Vdc output turns off. The Vsb output remains on. This signal is pulled to a standby voltage by a pull-up resistor internal to the power supply. The power supply fan(s) shall operate at the lowest speed. PWOK# (Power Good) PWOK is a power good signal and will assert HIGH when the outputs are within the regulation limits. PWOK will be pulled LOW by the power supply to indicate when either output falls below regulation limits or when AC power has been removed for a time sufficiently long so that power supply operation is no longer guaranteed. The start of the PWOK# delay time shall be inhibited as long as the +12 Vdc output is in current limit or the 5.0 Vsb output is below the regulation limit. PWOK Signal Characteristics Signal Type Open collector/drain output from power supply. Pullup to 5.0 Vsb external to the power supply. PWOK = High Power Good PWOK = Low Power Not Good MIN MAX To tLogic level low voltage, Ising = 4 mA 0 V 0.8 V Logic level high voltage, Isource = 200 µA 2.0 V 5 .2V Sink current, PWOK = low 4 mA Source current, PWOK = high 2 mA PWOK delay: T pwok_on 100 ms 1000 ms PWOK rise and fall time 100 µsec Power down delay: Tpson_off 1 msec 1000 msec PSON Signal Characteristics Signal Type Accepts an open collector/drain input from the system. Pulled-up to the 5.0 Vsb located in power supply. PSON# = Low ON PSON# = Open OFF MIN MAX Logic level low (power supply ON) 0 V 0.8 V Logic level high (power supply OFF) 2.0 V 5.2 V Source current, Vpson = low 4 mA Power up delay: Tpson_on_delay 5 msec 200 msec
6 advancedenergy.com DS800SL OUTPUTS - ALL MODELS (CONTINUED) ACOK# Signal Characteristics Signal Type Pull up to 5.0 Vsb through a resistor in the host system. Present = High Present Present = Low Not Present MIN MAX Logic level low voltage, Isink = 4 mA 0 V 0.8 V Logic level high voltage, Isink = 50 µA 2.0 V 5.2 V Sink current, PRESENT# = low 4 mA Sink current, PRESENT# = high 50 µsec Status Indicators Condition Status Signals Status Register Shutdown Register LED’s ACOK/L PWOK/H PSON PWOK Fan-Fail AC-Loss 0-Temp 0-Current Fail AC DC Fail Normal Operation 0 1 1 1 0 0 0 0 0 On On Off V1 12 V Overcurrent 0 0 1 0 0 0 0 1 1 On Off On AC Input Fail 1 0 1 0 0 1 0 0 1 Off Off Off Fan Blocked or Running Under Speed. O/P’s ok 0 1 1 1 0 0 0 0 0 On On Off UV on V1 12 V and PS Has Latched Off 0 0 1 0 0 0 0 0 1 On Off On UV on Vsb +5.0 and PS Has Turned Off 0 0 1 0 0 0 0 0 1 On Off On OV on V1 12V or Vsb +5.0 & PS Has Latched Off 0 0 1 0 0 0 0 0 1 On Off On Over Temp and PS Has Turned Off 0 0 1 0 0 0 1 0 1 On Off On Fan Below Shutdown Limit 0 0 1 0 1 0 0 0 1 On Off On No Problems But PS is in Standby Mode 0 0 0 0 0 0 0 0 0 On Off Off PSKILL The +12 Vdc output only from the power supply shall be disabled if the PSKILL input is high and V Standby will continue to be provided, outputs may be enabled if this signal is low. The power supply includes a pull up to disable all outputs if this signal is open. PSKILL whall not be connected during a hot insertion before all of the other pins are connected. AC INPUT PRESENT INDICATOR (ACOK/L) The ACOK signal is used to indicate presence of AC input to the power supply. This signal shall be connected to Vsb through a resistor on the host system side. A logic “Low” level on this signal shall indicate AC input to the power supply is present. A Logic “High” on this signal shall indicate a loss of AC input to the power supply. STATUS INDICATIONS See table below for Summary of Status signals, Ports and Indicators. The condition column assumes 2 or more power supplies present and ON and 5.0 Vsb shared for management interface. On the “Fan Blocked” condition, the assumption is that all outputs are within spec and not over temperature. This would be considered a “warning” condition. On the “Standby” condition, the system differentiates this state by knowing PS_ONL in negated (requesting Standby).
advancedenergy.com 7 DS800SL OUTPUT CONNECTOR AND PIN-OUT TABLE Pin Signal Name Pin 1 +12 V Pin 2 +12 V Pin 3 Ground Pin 4 Ground S1 +12 V Sense S2 +12 V RTN Sense S3 +12 V Current Share S4 SMB_ALERT/L S5 SDA S6 SCL* S7 PSKILL S8 PSON/L S9 PW_OK S10 PS_A1 S11 +5.0 V_STBY S12 +5.0 V_STBY S13 Reserved S14 PRESENT/L S15 PS_A0 S16 Reserved S17 Reserved for factory use S18 EEPROM_WP S19 ACOK/L S20 Not used S21 PS_A2 S22 V_STBY Remote Sense S23 V_STBY S24 V_STBY * Supports I C standard mode (100 kHz) only Ground Ground P2P1 P4P3 +12V +12V S12 S24 S13 Bottom Side Top Side Note: Pin number may not necessarily match vendor’s pin number assignment. Please follow the signal and number assignment as indicated in this datasheet
8 advancedenergy.com DS800SL MECHANICAL DRAWING BURN-IN 100% Burn-in at 45 °C, at 80-90% load. Duration of burn-in determined by Quality Assurance Procedures. MTBF The power supply has an MTBF of >400K hours using Telcordia SR-332 at full load, and 25 °C ambient. With the power supply installed in a system in a 25 °C ambient environment and operating at full load, capacitor life shall be 5 years, minimum for ALL electrolytic capacitors contained within this power supply. QUALITY ASSURANCE Full QAV testing shall be conducted in accordance with Artesyn Embedded Power Standards with reports available upon request. WARRANTY Artesyn Embedded Power shall warrant the power supply to be free of defects in materials and workmanship for a minimum period of two years from the date of shipment, when operated within specifications. The warranty shall be fully transferable to the end owner of the equipment powered by the supply.
ENG-DS800SL -235-01 12.14 For international contact information, visit advancedenergy .com. powersales@aei.com (Sales Support) productsupport.ep@aei.com (Technical Support) +1 888 412 7832 ABOUT ADVANCED ENERGY Advanced Energy (AE) has devoted more than three decades to perfecting power for its global customers. AE designs and manufactures highly engineered, precision power conversion, measurement and control solutions for mission-critical applications and processes. Our products enable customer innovation in complex applications for a wide range of industries including semiconductor equipment, industrial, manufacturing, telecommunications, data center computing, and medical. With deep applications know-how and responsive service and support across the globe, we build collaborative partnerships to meet rapid technological developments, propel growth for our customers, and innovate the future of power. Specifications are subject to change without notice. Not responsible for errors or omissions. ©2020 Advanced Energy Industries, Inc. All rights reserved. Advanced Energy®, AE® and Artesyn™ are U.S. trademarks of Advanced Energy Industries, Inc.