DS7000 TTELEC | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 2
Technical content
© TT electronics plc Issue A 07/2018 Page 1 TT Electronics | Roxspur Measurement & Control
2 Downgate Drive, Sheffield, South Yorkshire, S4 8BT, UK |Ph: +44 (0) 114 -244-2521
www.ttelectronics.com | RoxspurSales@ttelectronics.com General Note TT Electronics reserves the right to make changes in product specification without notice or liability. All information is subject to TT Electronics’ own data and is considered accurate at time of going to print. Description: The SL7000 is a data logger with a very flexible combination of inputs - from single temperature input, up to 4 universal inputs combined with an internal temperature and relative humidity sensor, as well as an optional external temperature and relative humidity sensor. All units also feature a digital input which can be used as an event trigger or as a counter input. Powered by its own user-replaceable batter with life in excess of 6 years, the SL7000 can record up to 120,000 readings at intervals from 1 second to 24 hours. It features unprecedented 16-bit accuracy and resolution for all universal inputs, and is competitively priced regardless of the application. An on-board LCD display (optional) shows selected channel information, and integral LED displays provide immediate scanning and alarm status information. Features: Universal inputs 1, 2, 3, 4, 5, 6, 7, 8 and 9 channels 16-bit resolution LCD display option User replaceable battery Typical 6 year battery life Digital input
© TT electronics plc General Note TT Electronics reserves the right to make changes in product specification without notice or liability. All information is subject to TT Electronics’ own data and is considered accurate at time of going to print. Issue A 07/2018 Page 2 TT Electronics | Roxspur Measurement & Control www.ttelectronics.com | RoxspurSales@ttelectronics.com Universal Inputs Pt100: 2 or 3 wire C or F (BS EN 60751/JIS 1604) Ni100, Ni120: 2 or 3 wire C or F Cu10: 2 or 3 wire C or F Thermocouples: J, K, T, R, S, B, N C or F Thermistor: (various types) C or F 0-20mA: scaled in engineering units ±100mV: DC scaled in engineering units 0-1V DC: scaled in engineering units 0-10V DC: scaled in engineering units Slidewire: scaled in engineering units (100ohm to 10kohm) Resolutions All universal inputs: 16-bit Internal and external temperature: 12-bit Internal and external RH: 8-bit Counter Input Used to start logging or as a counter Maximum count: 65,535 per sample period Maximum frequency: 32,768 Hz Start Options Programmable delay period: 10 min to 1 year Start on external magnet swipe Start on event trigger Channel Indicators 8 green LEDs to indicate logging status, changing to red to indicate alarm condition Comms Indicators 1 yellow LED to indicate comms activity Sample Rate 1 second to 24 hours for all channels Display Optional 3.5 digit LCD with channel indication and low battery warn- ing Communication Interface USB isolated (5-pin mini USB connector) Sample Method: Selectable Point, Averaging, Maximum, Minimum