DS486 BRIDGELUX | Alldatasheet
Document overview
- PDF pages: 16
Technical content
Bridgelux ® Pallas - A Single Channel 60W (0 - 10V) Linear Driver Product Data Sheet DS486
Bridgelux Pallas - A (0 - 10V) Single Channel 60W Driver provides dynamic constant current output for LED modules and arrays. This Driver interoperates with 0 - 10V standard lighting systems and protocols and allows for simple integration of Bridgelux’s and all major brands White Arrays and Linear modules. Please visit www.bridgelux.com for more information. The part number designation for Bridgelux Pallas - A (0 - 10V) Single Channel 60W Driver is explained as follows: Product Nomenclature Part Number Configuration BXDR - MP - 60LW - U114A - 01 - A Linear, US Universal Input 120/270VAC BXDR - MP - 60LW - U114A - 01 - A - 12 Linear, US Universal Input 120/277VAC, +12V AUX BXDR - MP - 60LW - C114A - 01 - A Linear, CAN Universal Input 120/277/347VAC BXDR - MP - 60LW - C114A - 01 - A - 12 Linear, CAN Universal Input 120/277/347VAC, +12V AUX Table 1: Product Selection Guide (examples) BXDR 60LW U114A 01 A - - - - Housing Material M = Metal Maximum Output Power 60 = 60W Form Factor L = Linear Connector Type W = Flying Wires Input Voltage U = US 120/277VAC C = CAN 120/277/347VAC Output Channels 1 = Single Channel Maximum Output Current x 100mA 14 = 1400 mA Control Input A = Analog 0 - 10V Product Version 01 = Standard Product Generation Blank = not added 12 = 12V AUX 12 - *Optional A = Generation A MP - 5,6 Current Setting P = Programmable 19,20 Product Family BXDR = Driver LED Output US Universal input 120/277 VAC CAN Universal input 120/277/347VAC 0 - 10V Control Case temperature measurement point Tc Programming Interface
Electrical Characteristics
Table 2: Input Electrical Characteristics Parameter Unit Specification Nominal voltage V 120 / 277 / 347 VAC Nominal frequency Hz 50 / 60 Hz AC voltage range V 108 – 382 VAC Input current (max) A < 0.70 A (@ 120V) < 0.25 A (@ 277V) < 0.21 A (@ 347V) THD (Full load) % < 10% (@ 120V) < 10% (@ 277V) < 15% (@ 347V) Power factor (Full load) - > 0.95 (@ 120V) > 0.95 (@ 277V) > 0.90 (@ 347V) Efficiency (Full load) % > 89% (@ 120V) > 89% (@ 277V) > 89% (@ 347V) NO load W ≤ 0.5 W Inrush current(Cold start) A pk < 15A @ 120V input 25 ° C cold start at 100% conditions. For more details in the attached graph Start - up Time s < 0.5 s Table 3: Output Electrical Characteristics Parameter Unit Specification Nominal voltage range V 20 – 50V (see Operating Window) Maximum voltage(Open Circuit) Vdc ≤ 60 V Programmable Output Current mA 140 – 1,400 mA Current accuracy % +/ - 5 % Current ripple 100Hz % ≤ 10 % Pst LM - ≤ 1 SVM - ≤ 0.4 Output Power (Max) W 60 W
Mechanical Characteristics Characteristics Specification Dimensions 241.3 mm (L) x 33.1 mm (W) x 28.0 mm (H) Enclosure Materials Steel Metal Weight 420 g Ingress Protection IP20 Table 5: Driver Mechanical Characteristics Figure 11: Mechanical Drawing Notes for Figure 11: 1. Drawing dimensions are in millimeters 2. Unless otherwise specified, all linear tolerances are +/ - 1.0mm
Notes for Table 6: 1. Hot plug - in or secondary switching of LEDs is not permitted and may cause a very high current to the LEDs. 2. Unless otherwise specified, all linear tolerances are +/ - 1.0mm PRI / DIM Cable AWG AWG 18 Cable Length 300 mm SEC / AUX Cable AWG AWG 20 Cable Length 300 mm Table 6: Wiring 0 - 10V Table 7: Auxiliary source 12V (Optional) Parameter Unit Specification Voltage range V 12V Current Range A 0.2A Auxiliary Source (Optional)
The Pallas - A Single Channel 60W Driver provides a programming port, which allows for programming specific driver settings in accordance with customer preferences. The Driver does not need to be powered during the programming of the driver settings. Bridgelux provides a programmer for programming the Pallas - A Single Channel Driver. For more information on the programmer, please see the Pallas - A Programmer data sheet on www.bridgelux.com or contact your local Bridgelux sales representative. User interface, Data communication Software Programmer Pallas - A 60mm x 35mm x 15mm USB JST XH Connector BXPR - MU - 01 - A
Programming Software (Bridgelux Driver Configuration ) Support Features:
- 1mA Current Programmable Step
- Max. Current Setting for LEDs (Level 5 field; Level 1 - 4 reserved for Bridgelux R&D only)
- Minimum Dimming Ratio (1%, 5%, 10%)
- Dim - To - Off: (ON/OFF) * Details please refer to “Bridgelux Driver Configuration Software User Manual ”
Environmental and Regulatory Standards Parameter Specification Ambient Operating Temperature - 20 ° C to + 50 ° C Max. Case Temperature Tc +90 ° C (max) Humidity Rating Maximum 90% Relative Humidity, non condensing Storage Temperature - 20 ° C to + 85 ° C Acoustic Noise < 24 dBA (measured from 1M w/o/dimmer) Expected Lifetime 50,000 hours (Tc < 90 ° C) Working Locations Suitable for dry and damp locations Warranty 5 Years (Tc < 90 ° C) Table 8: Environmental Conditions Table 9: Regulatory Approvals and Compliance Specification Reference Standard Condition Conducted and Radiated EMI FCC Title 47 Part 15B Class B at 120VAC, Class A at 277VAC & 347VAC Voltage Fluctuations & Flicker IEC 61000 - 3 - 3:2013+A1:2019 ESD (Electrostatic Discharge) IEC 61547:2009 Section 5.2 Test des.: IEC 61000 - 4 - 2 6 kV contact discharge, 8 kV air discharge, level 3 Electrical Fast Transient IEC 61547 Section 5.5 Test des.: IEC 61000 - 4 - 4 ± 2kV Direct couple to Line input, 5kHz repetition rate, 15mS duration, 300mS period. 7 coupling paths, 1 minute per path (14 total combinations) Surge Protection IEC 61547 Section 5.7 Test des.: IEC 61000 - 4 - 5 or ANSI/IEEE C62.41 - 2002 ± 2kV Common and Differential Mode, test at 2 Ω , 5 strikes/1minute interval (40 total strikes) ANSI/IEEE C62.41.1 - 2002 2.5kV Ring Wave, test at 30 Ω 7 Strikes/1 minute interval, Common and Differential mode, 56 total strikes Voltage Dips IEC 61547 Section 5.8, 5.9 Test des.: IEC 61000 - 4 - 11 >95% dip, .5 period; 30% dip, 25 periods; 95% reduction, 250 periods Note: Unless otherwise specified, all the above parameters are measured at ambient temperature of 25 ℃ and rated voltage.
Regulatory Standards (continued) Table 10: Safety Agency Approvals Specification Reference Standard Condition UL / cUL UL8750, CAN/CSA - C22.2 No. 250.13 UL Listed, Class 2, Class P Table 11: Protection Specification Reference Standard Condition Over Voltage Protection (OVP) YES Automatic recovery Over Temperature Protection (OTP) YES Gradually reduce output power when Tc exceed 90 ° C. Automatic recovery Output Short - Circuit Protection (SCP) YES Automatic recovery
Voltage I peak (A) Twidth (Time @50% of I peak ) 120VAC 11.1 A 354 μ s 277VAC 25.5 A 316 μ s 347VAC 33.5 A 274 μ s Table 12: Estimated Maximum Number of Drivers per Miniature Circuit Breaker (MCB) Input Voltage B10 C10 D10 B13 C13 D13 B16 C16 D16 B20 C20 D20 120VAC 10 12 14 14 16 18 17 20 23 21 25 29 277VAC 9 15 31 12 20 40 15 25 50 18 31 62 347VAC 8 13 26 10 17 34 12 21 42 16 26 53
Outer dimensions 330 X 305 X 210 mm Weight 11 kg Table 13: Packaging Box Configuration Figure 12: Packaging Box Design Notes for Figure 12: 1. Each box contains 4 layers with 6 drivers in each layer. Each layer is separated by horizontal dividers. There are 5 horizontal dividers per box.
Please contact your Bridgelux sales representative for assistance on obtaining application support when designing with the Bridgelux Pallas - A Single Channel Driver. For a list of available resources, visit www.bridgelux.com. Precautions CAUTION: PRODUCT HANDLING Handle the Pallas - A Single Channel Driver with care to prevent any damage from mechanical shock It is recommended to handle this driver in a static - free environment Do not open or disassemble the product To maintain product warranty, the installer is responsible for ensuring that the driver's operating conditions do not exceed the maximum conditions stated within this data sheet CAUTION: PRODUCT INSTALLATION Incorrect installation of the Pallas - A Single Channel Driver can cause irreparable damage to the driver, connected LEDs. Pay attention when connecting the LED load and observe the correct polarity of the output terminals as specified in this data sheet and on the driver label. CAUTION: ELECTRIC SHOCK Be aware of the possibility of an electric shock hazard which can result in serious injury or death. Disconnect power before servicing or installing this device. Disclaimers MINOR PRODUCT CHANGE POLICY The rigorous qualification testing on products offered by Bridgelux provides performance assurance. Slight cosmetic changes that do not affect form, fit, or function may occur as Bridgelux continues product optimization.
About Bridgelux: Bridging Light and Life TM At Bridgelux, we help companies, industries and people experience the power and possibility of light. Since 2002, we’ve designed LED solutions that are high performing, energy efficient, cost effective and easy to integrate. Our focus is on light’s impact on human behavior, delivering products that create better environments, experiences and returns — both experiential and financial. And our patented technology drives new platforms for commercial and industrial luminaires. For more information about the company, please visit bridgelux.com twitter.com/Bridgelux facebook.com/Bridgelux youtube.com/user/Bridgelux linkedin.com/company/bridgelux WeChat ID: BridgeluxInChina
46410 Fremont Blvd
Fremont, CA 94538 USA Tel (925) 583 - 8400 www.bridgelux.com © 2022 Bridgelux, Inc. All rights reserved 2022. Product specifications are subject to change without notice. Bridgelux, the Bri dgelux stylized logo design and Pallas - A are registered trademarks of Bridgelux, Inc. Bridging Light and Life is a trademark of Bridgelux, Inc. All other trademarks are t he property of their respective owners. Bridgelux Pallas - A (0 - 10V) Single Channel 60W Driver Data Sheet DS486 Rev. A (08/2022)