DS432 BRIDGELUX | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 34
Technical content
Datasheet sections
The Vero® SE Series is a revolutionary light source system that integrates Bridgelux’s eighth generation COB technology with poke-in connectivity, enabling solder-free installation. Vero SE LED light sources streamline assembly processes, lower manufacturing costs, simplify the luminaire design process, improve light quality, and increase design flexibility. Vero SE is available in four different light emitting surface (LES) configurations that operate reliably over a broad current range. With Vero SE, secondary connector and holder components are not required, allowing for rapid integration of arrays into fixtures, and an efficient field replaceable solution. Vero SE arrays deliver increased lumen density for improved beam control and precision lighting, with 2 and 3 SDCM color control standards for clean and consistent uniform lighting. Vero SE
Features
- Poke-in electrical connectivity
- Top side part number markings
- Efficacy of 177 lm/W typical, 3000K 80 CRI
- Reliable operation at up to 3x nominal current, 30% increase in maximum lumens per LES size
- Wide selection of CCT options (2700K-6500K) with minimum 70, 80 and 90 CRI options
- Uniform high-quality illumination
- 2 and 3 SDCM binning options (2700K – 4000K)
- Forward voltage bin codes (backside marking)
- 10-Year warranty Benefits
- Low cost, solderless, connector free installation and field upgradability
- Improved inventory management and quality control
- Enables high efficiency lighting systems and lower operating costs
- Supports the trend toward luminaire miniaturization and delivers enhanced optical control
- Design flexibility for a broad range of lighting applica- tions
- Clean white light without pixelation
- Uniform consistent white light
- Design flexibility for multi-source applications
- Design with confidence
Vero SE 18 is the second largest form factor in the product family of next generation solid state light sources. In addition to delivering the performance and light quality required for many lighting applications, Vero SE incorporates several features to simplify the design integration and manufacturing process, accelerate time to market and reduce system costs. Please visit www. bridgelux.com for more information on the Vero SE family of products. Product Nomenclature The part number designation for Bridgelux Vero SE LED arrays is explained as follows: 1 2 3 4 – 5 6 7 8 9 10 11 – 12 – 13 14 – 15 16 Product Family CCT Bin Options 2 = 2 SDCM 3 = 3 SDCM 4 = 4 SDCM CRI C = 70 CRI min. E = 80 CRI min. G = 90 CRI min. H = 97 CRI typ. Array Configuration 27 = 2,700K 30 = 3,000K 35 = 3,500K 40 = 4,000K 50 = 5,000K 57 = 5,700K 65 = 6,500K BXRC – 30 E 400 0 – C – 8 3 – SE Color Targeting Designator 0 = Cold Targeted 1 = Hot Targeted C = Decor Series Showcase Target Gen. 8 Nominal CCT Flux Indicator 400x = 4000 lm Special Edition 2D Bar code provides full manufacturing traceability Polarity indication marks simplify manufacturing operator instructions Optic mounting holes Mounting holes Zhaga Book 3 compatible mounting locations Tc Measurement point Radial die configuration improves lumen density and beam control Top side part number marking improves inventory management and outgoing quality control Dual poke-in connectivity Wire release mechanisms x4 Test ports for probing
The following product configurations are available: Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-27E4000-B-8x-SE 2700 80 700 3976 3578 33.9 23.7 168 BXRC-27E4000-C-8x-SE 2700 80 1050 5945 5351 33.9 35.6 167 BXRC-27E4000-D-8x-SE 2700 80 850 4002 3602 28.2 24.0 167 BXRC-27G4000-B-8x-SE 2700 90 700 3280 2952 33.9 23.7 138 BXRC-27G4000-C-8x-SE 2700 90 1050 4905 4414 33.9 35.6 138 BXRC-27G4000-D-8x-SE 2700 90 850 3302 2971 28.2 24.0 138 BXRC-27G40H0-B-8x-SE 2700 90 700 3422 3080 33.9 23.7 144 BXRC-27G40H0-C-8x-SE 2700 90 1050 5117 4605 33.9 35.6 144 BXRC-27G40H0-D-8x-SE 2700 90 850 3444 3100 28.2 24.0 144 BXRC-27H4000-B-8x-SE 2700 97 700 2907 2617 33.9 23.7 123 BXRC-27H4000-C-8x-SE 2700 97 1050 4347 3913 33.9 35.6 122 BXRC-27H4000-D-8x-SE 2700 97 850 2926 2634 28.2 24.0 122 BXRC-30C4001-B-8x-SE 3000 70 700 4423 3981 33.9 23.7 186 BXRC-30C4001-C-8x-SE 3000 70 1050 6614 5953 33.9 35.6 186 BXRC-30C4001-D-8x-SE 3000 70 850 4452 4007 28.2 24.0 186 BXRC-30E4000-B-8x-SE 3000 80 700 4224 3802 33.9 23.7 178 BXRC-30E4000-C-8x-SE 3000 80 1050 6317 5685 33.9 35.6 177 BXRC-30E4000-D-8x-SE 3000 80 850 4252 3827 28.2 24.0 177 BXRC-30G4000-B-8x-SE 3000 90 700 3429 3086 33.9 23.7 145 BXRC-30G4000-C-8x-SE 3000 90 1050 5128 4615 33.9 35.6 144 BXRC-30G4000-D-8x-SE 3000 90 850 3452 3106 28.2 24.0 144 BXRC-30G40H0-B-8x-SE 3000 90 700 3591 3232 33.9 23.7 151 BXRC-30G40H0-C-8x-SE 3000 90 1050 5369 4832 33.9 35.6 151 BXRC-30G40H0-D-8x-SE 3000 90 850 3614 3253 28.2 24.0 151 BXRC-30H4000-B-8x-SE 3000 97 700 3106 2796 33.9 23.7 131 BXRC-30H4000-C-8x-SE 3000 97 1050 4645 4180 33.9 35.6 130 BXRC-30H4000-D-8x-SE 3000 97 850 3126 2814 28.2 24.0 130 BXRC-35E4000-B-8x-SE 3500 80 700 4324 3891 33.9 23.7 182 BXRC-35E4000-C-8x-SE 3500 80 1050 6465 5819 33.9 35.6 182 BXRC-35E4000-D-8x-SE 3500 80 850 4352 3917 28.2 24.0 182 BXRC-35G4000-B-8x-SE 3500 90 700 3553 3198 33.9 23.7 150 BXRC-35G4000-C-8x-SE 3500 90 1050 5314 4782 33.9 35.6 149 BXRC-35G4000-D-8x-SE 3500 90 850 3577 3219 28.2 24.0 149 BXRC-40C4001-B-8x-SE 4000 70 700 4547 4093 33.9 23.7 192 BXRC-40C4001-C-8x-SE 4000 70 1050 6800 6120 33.9 35.6 191 BXRC-40C4001-D-8x-SE 4000 70 850 4577 4119 28.2 24.0 191 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are minimums for all products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50. the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test.
Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-40E4000-B-8x-SE 4000 80 700 4349 3914 33.9 23.7 183 BXRC-40E4000-C-8x-SE 4000 80 1050 6503 5852 33.9 35.6 183 BXRC-40E4000-D-8x-SE 4000 80 850 4377 3939 28.2 24.0 183 BXRC-40G4000-B-8x-SE 4000 90 700 3628 3265 33.9 23.7 153 BXRC-40G4000-C-8x-SE 4000 90 1050 5425 4883 33.9 35.6 152 BXRC-40G4000-D-8x-SE 4000 90 850 3652 3287 28.2 24.0 152 BXRC-40H4000-B-8x-SE 4000 97 700 3241 2917 33.9 23.7 137 BXRC-50C4001-B-8x-SE 5000 70 700 4572 4115 33.9 23.7 193 BXRC-50C4001-C-8x-SE 5000 70 1050 6837 6153 33.9 35.6 192 BXRC-50C4001-D-8x-SE 5000 70 850 4602 4142 28.2 24.0 192 BXRC-50E4001-B-8x-SE 5000 80 700 4398 3958 33.9 23.7 185 BXRC-50E4001-C-8x-SE 5000 80 1050 6577 5919 33.9 35.6 185 BXRC-50E4001-D-8x-SE 5000 80 850 4427 3984 28.2 24.0 185 BXRC-50G4001-B-8x-SE 5000 90 700 3802 3422 33.9 23.7 160 BXRC-50G4001-C-8x-SE 5000 90 1050 5685 5117 33.9 35.6 160 BXRC-50G4001-D-8x-SE 5000 90 850 3827 3444 28.2 24.0 160 BXRC-57C4001-B-8x-SE 5700 70 700 4448 4003 33.9 23.7 187 BXRC-57C4001-C-8x-SE 5700 70 1050 6651 5986 33.9 35.6 187 BXRC-57C4001-D-8x-SE 5700 70 850 4477 4029 28.2 24.0 187 BXRC-57E4001-B-8x-SE 5700 80 700 4224 3802 33.9 23.7 178 BXRC-57E4001-C-8x-SE 5700 80 1050 6317 5685 33.9 35.6 177 BXRC-57E4001-D-8x-SE 5700 80 850 4252 3827 28.2 24.0 177 BXRC-65C4001-B-8x-SE 6500 70 700 4448 4003 33.9 23.7 187 BXRC-65C4001-C-8x-SE 6500 70 1050 6651 5986 33.9 35.6 187 BXRC-65C4001-D-8x-SE 6500 70 850 4477 4029 28.2 24.0 187 BXRC-65E4001-B-8x-SE 6500 80 700 4274 3847 33.9 23.7 180 BXRC-65E4001-C-8x-SE 6500 80 1050 6391 5752 33.9 35.6 180 BXRC-65E4001-D-8x-SE 6500 80 850 4302 3872 28.2 24.0 179 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are minimums for all products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50. the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ±3 tolerance for all CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test.
Table 2: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-27E4000-B-8x-SE 2700 80 700 3578 3220 33.1 23.2 154 BXRC-27E4000-C-8x-SE 2700 80 1050 5351 4816 33.1 34.8 154 BXRC-27E4000-D-8x-SE 2700 80 850 3602 3242 27.7 23.5 153 BXRC-27G4000-B-8x-SE 2700 90 700 2952 2657 33.1 23.2 127 BXRC-27G4000-C-8x-SE 2700 90 1050 4414 3973 33.1 34.8 127 BXRC-27G4000-D-8x-SE 2700 90 850 2971 2674 27.7 23.5 126 BXRC-27G40H0-B-8x-SE 2700 90 700 3080 2772 33.1 23.2 133 BXRC-27G40H0-C-8x-SE 2700 90 1050 4605 4144 33.1 34.8 132 BXRC-27G40H0-D-8x-SE 2700 90 850 3100 2790 27.7 23.5 132 BXRC-27H4000-B-8x-SE 2700 97 700 2617 2355 33.1 23.2 113 BXRC-27H4000-C-8x-SE 2700 97 1050 3913 3521 33.1 34.8 113 BXRC-27H4000-D-8x-SE 2700 97 850 2634 2370 27.7 23.5 112 BXRC-30C4001-B-8x-SE 3000 70 700 3981 3583 33.1 23.2 172 BXRC-30C4001-C-8x-SE 3000 70 1050 5953 5357 33.1 34.8 171 BXRC-30C4001-D-8x-SE 3000 70 850 4007 3606 27.7 23.5 170 BXRC-30E4000-B-8x-SE 3000 80 700 3802 3422 33.1 23.2 164 BXRC-30E4000-C-8x-SE 3000 80 1050 5685 5117 33.1 34.8 163 BXRC-30E4000-D-8x-SE 3000 80 850 3827 3444 27.7 23.5 163 BXRC-30G4000-B-8x-SE 3000 90 700 3086 2778 33.1 23.2 133 BXRC-30G4000-C-8x-SE 3000 90 1050 4615 4153 33.1 34.8 133 BXRC-30G4000-D-8x-SE 3000 90 850 3106 2796 27.7 23.5 132 BXRC-30G40H0-B-8x-SE 3000 90 700 3232 2908 33.1 23.2 139 BXRC-30G40H0-C-8x-SE 3000 90 1050 4832 4349 33.1 34.8 139 BXRC-30G40H0-D-8x-SE 3000 90 850 3253 2927 27.7 23.5 138 BXRC-30H4000-B-8x-SE 3000 97 700 2796 2516 33.1 23.2 121 BXRC-30H4000-C-8x-SE 3000 97 1050 4180 3762 33.1 34.8 120 BXRC-30H4000-D-8x-SE 3000 97 850 2814 2532 27.7 23.5 120 BXRC-35E4000-B-8x-SE 3500 80 700 3891 3502 33.1 23.2 168 BXRC-35E4000-C-8x-SE 3500 80 1050 5819 5237 33.1 34.8 167 BXRC-35E4000-D-8x-SE 3500 80 850 3917 3525 27.7 23.5 167 BXRC-35G4000-B-8x-SE 3500 90 700 3198 2878 33.1 23.2 138 BXRC-35G4000-C-8x-SE 3500 90 1050 4782 4304 33.1 34.8 138 BXRC-35G4000-D-8x-SE 3500 90 850 3219 2897 27.7 23.5 137 BXRC-40C4001-B-8x-SE 4000 70 700 4093 3683 33.1 23.2 177 BXRC-40C4001-C-8x-SE 4000 70 1050 6120 5508 33.1 34.8 176 BXRC-40C4001-D-8x-SE 4000 70 850 4119 3707 27.7 23.5 175 Notes for Table 2: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are minimums for all products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50. the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ±3 tolerance for all CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
Table 2: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-40E4000-B-8x-SE 4000 80 700 3914 3522 33.1 23.2 169 BXRC-40E4000-C-8x-SE 4000 80 1050 5852 5267 33.1 34.8 168 BXRC-40E4000-D-8x-SE 4000 80 850 3939 3545 27.7 23.5 168 BXRC-40G4000-B-8x-SE 4000 90 700 3265 2939 33.1 23.2 141 BXRC-40G4000-C-8x-SE 4000 90 1050 4883 4394 33.1 34.8 140 BXRC-40G4000-D-8x-SE 4000 90 850 3287 2958 27.7 23.5 140 BXRC-40H4000-B-8x-SE 4000 97 700 2917 2625 33.1 23.2 126 BXRC-50C4001-B-8x-SE 5000 70 700 4115 3704 33.1 23.2 177 BXRC-50C4001-C-8x-SE 5000 70 1050 6153 5538 33.1 34.8 177 BXRC-50C4001-D-8x-SE 5000 70 850 4142 3728 27.7 23.5 176 BXRC-50E4001-B-8x-SE 5000 80 700 3958 3563 33.1 23.2 171 BXRC-50E4001-C-8x-SE 5000 80 1050 5919 5327 33.1 34.8 170 BXRC-50E4001-D-8x-SE 5000 80 850 3984 3586 27.7 23.5 169 BXRC-50G4001-B-8x-SE 5000 90 700 3422 3080 33.1 23.2 148 BXRC-50G4001-C-8x-SE 5000 90 1050 5117 4605 33.1 34.8 147 BXRC-50G4001-D-8x-SE 5000 90 850 3444 3100 27.7 23.5 146 BXRC-57C4001-B-8x-SE 5700 70 700 4003 3603 33.1 23.2 173 BXRC-57C4001-C-8x-SE 5700 70 1050 5986 5387 33.1 34.8 172 BXRC-57C4001-D-8x-SE 5700 70 850 4029 3626 27.7 23.5 171 BXRC-57E4001-B-8x-SE 5700 80 700 3802 3422 33.1 23.2 164 BXRC-57E4001-C-8x-SE 5700 80 1050 5685 5117 33.1 34.8 163 BXRC-57E4001-D-8x-SE 5700 80 850 3827 3444 27.7 23.5 163 BXRC-65C4001-B-8x-SE 6500 70 700 4003 3603 33.1 23.2 173 BXRC-65C4001-C-8x-SE 6500 70 1050 5986 5387 33.1 34.8 172 BXRC-65C4001-D-8x-SE 6500 70 850 4029 3626 27.7 23.5 171 BXRC-65E4001-B-8x-SE 6500 80 700 3847 3462 33.1 23.2 166 BXRC-65E4001-C-8x-SE 6500 80 1050 5752 5177 33.1 34.8 165 BXRC-65E4001-D-8x-SE 6500 80 850 3872 3485 27.7 23.5 165 Notes for Table 2: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are minimums for all products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50. the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ±3 tolerance for all CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
European Product Registry for Energy Labeling The European Product Registry for Energy Labeling (EPREL) is defined in the EU Regulation 2017/1369 to provide import- ant energy efficiency information to consumers. Together with Energy Labeling Regulation ELR (EU) 2019/2015 which was amended by regulation (EU) 2021/340 for energy labelling of light sources, manufacturers are required to declare an ener- gy class based on key technical specifications from each of their product and register it in an open data base managed by EPREL It is now a legal requirement for a vendor of light sources to upload information about their products into the EPREL database before placing these products on the market in the EU. Table 3 below provides a list of part numbers that are in compliance with ELR and are currently listed in the EPREL data- base. At Bridgelux, we are fully committed to supplying products that are compliant with pertinent laws, rules, and obligation imposed by relevant government bodies including the European Energy Labeling regulation. Customers can use these products with full confidence for any projects that fall under the ELR. Table 3: Part numbers registered in European Product Registry for Energy Labeling PART NUMBER1 CCT (K) CRI Current2 (mA) Vf (V) Useful flux3 (Φuse) at 85C (lm) Pow- er (W) Efficacy (lm/W) Energy efficiency class4 Regis- tration No URL to Product Information Sheet in EPREL Database Notes for Table 3: 1. All device listed here must be disposed as e-waste upon its end of life according to local country guideline in each country. 2. For information on performance values at alternative drive conditions. please refer to the Product Selection Guide, Absolute Maximum Rating Table and Performance Curves in this data sheet. 3. For a definition of useful luminous flux (ΦΦuse), please see the ELR regulations at https:/ /tinyurl.com/4b6zvt4m. 4. EPREL requires an arrow symbol containing the letter of the energy efficiency class to be displayed. on technical promotional material. Refer to this energy efficiency class column for specific energy efficiency class on each part number.
European Product Registry for Energy Labeling Table 3: Part numbers registered in European Product Registry for Energy Labeling (Continued) PART NUMBER1 CCT (K) CRI Current2 (mA) Vf (V) Useful flux3 (Φuse) at 85C (lm) Pow- er (W) Efficacy (lm/W) Energy efficiency class4 Regis- tration No URL to Product Information Sheet in EPREL Database Notes for Table 3: 1. All device listed here must be disposed as e-waste upon its end of life according to local country guideline in each country. 2. For information on performance values at alternative drive conditions. please refer to the Product Selection Guide, Absolute Maximum Rating Table and Performance Curves in this data sheet. 3. For a definition of useful luminous flux (ΦΦuse), please see the ELR regulations at https:/ /tinyurl.com/4b6zvt4m. 4. EPREL requires an arrow symbol containing the letter of the energy efficiency class to be displayed. on technical promotional material. Refer to this energy efficiency class column for specific energy efficiency class on each part number.
European Product Registry for Energy Labeling Table 3: Part numbers registered in European Product Registry for Energy Labeling (Continued) PART NUMBER1 CCT (K) CRI Current2 (mA) Vf (V) Useful flux3 (Φuse) at 85C (lm) Pow- er (W) Efficacy (lm/W) Energy efficiency class4 Regis- tration No URL to Product Information Sheet in EPREL Database Notes for Table 3: 1. All device listed here must be disposed as e-waste upon its end of life according to local country guideline in each country. 2. For information on performance values at alternative drive conditions. please refer to the Product Selection Guide, Absolute Maximum Rating Table and Performance Curves in this data sheet. 3. For a definition of useful luminous flux (ΦΦuse), please see the ELR regulations at https:/ /tinyurl.com/4b6zvt4m. 4. EPREL requires an arrow symbol containing the letter of the energy efficiency class to be displayed. on technical promotional material. Refer to this energy efficiency class column for specific energy efficiency class on each part number.
Performance at Commonly Used Drive Currents Vero LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. Vero SE may also be driven at other drive currents dependent on specific application design requirements. The performance at any drive current can be derived from the current vs. voltage characteristics shown in Figures 1, 2 & 3 and the flux vs. current characteristics shown in Figures 4, 5 & 6. The performance at commonly used drive currents is summarized in Table 4. Table 4: Product Performance at Commonly Used Drive Currents Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-27E4000-B-8x-SE 80 350 32.7 11.4 2087 1878 182 525 33.3 17.5 3025 2723 173 700 33.9 23.7 3976 3578 168 900 34.5 31.0 4988 4489 161 1400 36.0 50.4 7501 6751 149 2000 37.5 75.1 10363 9327 138 BXRC-27E4000-C-8x-SE 80 525 32.7 17.2 3121 2809 182 785 33.3 26.1 4511 4060 173 1050 33.9 35.6 5945 5351 167 1170 34.1 39.9 6530 5877 164 2100 36.0 75.5 11217 10095 148 3000 37.5 112.6 15496 13947 138 BXRC-27E4000-D-8x-SE 80 425 27.2 11.6 2101 1891 182 650 27.7 18.0 3100 2790 172 850 28.2 23.9 4002 3602 167 1050 28.6 30.0 4837 4354 161 1700 29.9 50.9 7551 6795 148 2500 31.3 78.3 10704 9634 137 BXRC-27G4000-B-8x-SE 90 350 32.7 11.4 1722 1550 151 525 33.3 17.5 2496 2246 143 700 33.9 23.7 3280 2952 138 900 34.5 31.0 4115 3703 133 1400 36.0 50.4 6189 5570 123 2000 37.5 75.1 8550 7695 114 BXRC-27G4000-C-8x-SE 90 525 32.7 17.2 2575 2317 150 785 33.3 26.1 3721 3349 142 1050 33.9 35.6 4905 4414 138 1170 34.1 39.9 5387 4849 135 2100 36.0 75.5 9254 8329 122 3000 37.5 112.6 12784 11506 114 BXRC-27G4000-D-8x-SE 90 425 27.2 11.6 1733 1560 150 650 27.7 18.0 2558 2302 142 850 28.2 23.9 3302 2971 138 1050 28.6 30.0 3991 3592 133 1700 29.9 50.9 6229 5606 122 2500 31.3 78.3 8831 7948 113 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-27G40H0-B-8x-SE 90 350 32.7 11.4 1796 1617 157 525 33.3 17.5 2604 2343 149 700 33.9 23.7 3422 3080 144 900 34.5 31.0 4293 3863 138 1400 36.0 50.4 6456 5810 128 2000 37.5 75.1 8919 8027 119 BXRC-27G40H0-C-8x-SE 90 525 32.7 17.2 2686 2417 157 785 33.3 26.1 3882 3494 149 1050 33.9 35.6 5117 4605 144 1170 34.1 39.9 5620 5058 141 2100 36.0 75.5 9654 8688 128 3000 37.5 112.6 13336 12003 118 BXRC-27G40H0-D-8x-SE 90 425 27.2 11.6 1808 1627 157 650 27.7 18.0 2668 2401 148 850 28.2 23.9 3444 3100 144 1050 28.6 30.0 4163 3747 139 1700 29.9 50.9 6498 5848 128 2500 31.3 78.3 9212 8291 118 BXRC-27H4000-B-8x-SE 97 typ. 350 32.7 11.4 1526 1374 133 525 33.3 17.5 2212 1991 127 700 33.9 23.7 2907 2617 123 900 34.5 31.0 3647 3283 117 1400 36.0 50.4 5485 4937 109 2000 37.5 75.1 7578 6820 101 BXRC-27H4000-C-8x-SE 97 typ. 525 32.7 17.2 2282 2054 133 785 33.3 26.1 3299 2969 126 1050 33.9 35.6 4347 3913 122 1170 34.1 39.9 4775 4298 120 2100 36.0 75.5 8203 7382 109 3000 37.5 112.6 11332 10198 101 BXRC-27H4000-D-8x-SE 97 typ. 425 27.2 11.6 1536 1383 133 650 27.7 18.0 2267 2040 126 850 28.2 23.9 2926 2634 122 1050 28.6 30.0 3537 3184 118 1700 29.9 50.9 5521 4969 109 2500 31.3 78.3 7827 7045 100 BXRC-30C4001-B-8x-SE 70 350 32.7 11.4 2322 2090 203 525 33.3 17.5 3366 3029 193 700 33.9 23.7 4423 3981 187 900 34.5 31.0 5549 4994 179 1400 36.0 50.4 8345 7511 166 2000 37.5 75.1 11529 10376 154 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Table 4: Product Performance at Commonly Used Drive Currents (Continued) Performance at Commonly Used Drive Currents Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-30C4001-C-8x-SE 70 525 32.7 17.2 3472 3125 202 785 33.3 26.1 5018 4516 192 1050 33.9 35.6 6614 5953 186 1170 34.1 39.9 7265 6538 182 2100 36.0 75.5 12479 11231 165 3000 37.5 112.6 17240 15516 153 BXRC-30C4001-D-8x-SE 70 425 27.2 11.6 2337 2103 202 650 27.7 18.0 3449 3104 192 850 28.2 23.9 4452 4007 186 1050 28.6 30.0 5382 4843 179 1700 29.9 50.9 8400 7560 165 2500 31.3 78.3 11908 10718 152 BXRC-30E4000-B-8x-SE 80 350 32.7 11.4 2218 1996 194 525 33.3 17.5 3215 2893 184 700 33.9 23.7 4224 3802 178 900 34.5 31.0 5299 4770 171 1400 36.0 50.4 7970 7173 158 2000 37.5 75.1 11011 9910 147 BXRC-30E4000-C-8x-SE 80 525 32.7 17.2 3316 2984 193 785 33.3 26.1 4793 4313 183 1050 33.9 35.6 6317 5685 178 1170 34.1 39.9 6938 6244 174 2100 36.0 75.5 11918 10726 158 3000 37.5 112.6 16465 14818 146 BXRC-30E4000-D-8x-SE 80 425 27.2 11.6 2232 2009 193 650 27.7 18.0 3294 2965 183 850 28.2 23.9 4252 3827 178 1050 28.6 30.0 5140 4626 171 1700 29.9 50.9 8022 7220 158 2500 31.3 78.3 11373 10236 145 BXRC-30G4000-B-8x-SE 90 350 32.7 11.4 1800 1620 157 525 33.3 17.5 2609 2349 149 700 33.9 23.7 3429 3086 145 900 34.5 31.0 4302 3872 139 1400 36.0 50.4 6470 5823 128 2000 37.5 75.1 8938 8044 119 BXRC-30G4000-C-8x-SE 90 525 32.7 17.2 2692 2423 157 785 33.3 26.1 3891 3502 149 1050 33.9 35.6 5128 4615 144 1170 34.1 39.9 5632 5069 141 2100 36.0 75.5 9675 8707 128 3000 37.5 112.6 13366 12029 119 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-30G4000-D-8x-SE 90 425 27.2 11.6 1812 1631 157 650 27.7 18.0 2674 2407 148 850 28.2 23.9 3452 3106 144 1050 28.6 30.0 4172 3755 139 1700 29.9 50.9 6512 5861 128 2500 31.3 78.3 9232 8309 118 BXRC-30G40H0-B-8x-SE 90 350 32.7 11.4 1885 1696 165 525 33.3 17.5 2732 2459 156 700 33.9 23.7 3591 3232 152 900 34.5 31.0 4505 4054 145 1400 36.0 50.4 6775 6097 135 2000 37.5 75.1 9359 8423 125 BXRC-30G40H0-C-8x-SE 90 525 32.7 17.2 2819 2537 164 785 33.3 26.1 4074 3666 156 1050 33.9 35.6 5369 4832 151 1170 34.1 39.9 5897 5308 148 2100 36.0 75.5 10131 9117 134 3000 37.5 112.6 13995 12596 124 BXRC-30G40H0-D-8x-SE 90 425 27.2 11.6 1897 1708 164 650 27.7 18.0 2800 2520 155 850 28.2 23.9 3614 3253 151 1050 28.6 30.0 4369 3932 145 1700 29.9 50.9 6819 6137 134 2500 31.3 78.3 9667 8700 123 BXRC-30H4000-B-8x-SE 97 typ. 350 32.7 11.4 1631 1468 143 525 33.3 17.5 2364 2127 135 700 33.9 23.7 3106 2796 131 900 34.5 31.0 3897 3507 126 1400 36.0 50.4 5861 5274 116 2000 37.5 75.1 8096 7287 108 BXRC-30H4000-C-8x-SE 97 typ. 525 32.7 17.2 2438 2194 142 785 33.3 26.1 3524 3172 135 1050 33.9 35.6 4645 4180 131 1170 34.1 39.9 5102 4591 128 2100 36.0 75.5 8763 7887 116 3000 37.5 112.6 12106 10896 108 BXRC-30H4000-D-8x-SE 97 typ. 425 27.2 11.6 1641 1477 142 650 27.7 18.0 2422 2180 134 850 28.2 23.9 3126 2814 131 1050 28.6 30.0 3779 3401 126 1700 29.9 50.9 5899 5309 116 2500 31.3 78.3 8363 7526 107 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-35E4000-B-8x-SE 80 350 32.7 11.4 2270 2043 198 525 33.3 17.5 3290 2961 188 700 33.9 23.7 4324 3891 182 900 34.5 31.0 5424 4882 175 1400 36.0 50.4 8158 7342 162 2000 37.5 75.1 11270 10143 150 BXRC-35E4000-C-8x-SE 80 525 32.7 17.2 3394 3055 198 785 33.3 26.1 4905 4415 188 1050 33.9 35.6 6465 5819 182 1170 34.1 39.9 7101 6391 178 2100 36.0 75.5 12199 10979 161 3000 37.5 112.6 16852 15167 150 BXRC-35E4000-D-8x-SE 80 425 27.2 11.6 2285 2056 198 650 27.7 18.0 3372 3034 187 850 28.2 23.9 4352 3917 182 1050 28.6 30.0 5261 4735 175 1700 29.9 50.9 8211 7390 161 2500 31.3 78.3 11641 10477 149 BXRC-35G4000-B-8x-SE 90 350 32.7 11.4 1865 1679 163 525 33.3 17.5 2704 2434 155 700 33.9 23.7 3553 3198 150 900 34.5 31.0 4458 4012 144 1400 36.0 50.4 6704 6034 133 2000 37.5 75.1 9262 8336 123 BXRC-35G4000-C-8x-SE 90 525 32.7 17.2 2789 2510 163 785 33.3 26.1 4032 3628 154 1050 33.9 35.6 5314 4782 149 1170 34.1 39.9 5836 5253 146 2100 36.0 75.5 10025 9023 133 3000 37.5 112.6 13850 12465 123 BXRC-35G4000-D-8x-SE 90 425 27.2 11.6 1878 1690 163 650 27.7 18.0 2771 2494 154 850 28.2 23.9 3577 3219 149 1050 28.6 30.0 4323 3891 144 1700 29.9 50.9 6748 6073 133 2500 31.3 78.3 9567 8610 122 BXRC-40C4001-B-8x-SE 70 350 32.7 11.4 2387 2148 209 525 33.3 17.5 3460 3114 198 700 33.9 23.7 4547 4093 192 900 34.5 31.0 5705 5134 184 1400 36.0 50.4 8580 7722 170 2000 37.5 75.1 11853 10668 158 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-40C4001-C-8x-SE 70 525 32.7 17.2 3570 3213 208 785 33.3 26.1 5159 4643 198 1050 33.9 35.6 6800 6120 191 1170 34.1 39.9 7469 6722 187 2100 36.0 75.5 12830 11547 170 3000 37.5 112.6 17724 15951 157 BXRC-40C4001-D-8x-SE 70 425 27.2 11.6 2403 2163 208 650 27.7 18.0 3546 3191 197 850 28.2 23.9 4577 4119 191 1050 28.6 30.0 5533 4979 184 1700 29.9 50.9 8636 7772 170 2500 31.3 78.3 12243 11019 156 BXRC-40E4000-B-8x-SE 80 350 32.7 11.4 2283 2055 200 525 33.3 17.5 3309 2978 189 700 33.9 23.7 4349 3914 183 900 34.5 31.0 5455 4910 176 1400 36.0 50.4 8205 7384 163 2000 37.5 75.1 11335 10201 151 BXRC-40E4000-C-8x-SE 80 525 32.7 17.2 3414 3072 199 785 33.3 26.1 4934 4440 189 1050 33.9 35.6 6503 5852 183 1170 34.1 39.9 7142 6428 179 2100 36.0 75.5 12269 11042 162 3000 37.5 112.6 16949 15254 151 BXRC-40E4000-D-8x-SE 80 425 27.2 11.6 2298 2068 199 650 27.7 18.0 3391 3052 188 850 28.2 23.9 4377 3939 183 1050 28.6 30.0 5291 4762 176 1700 29.9 50.9 8258 7433 162 2500 31.3 78.3 11708 10537 149 BXRC-40G4000-B-8x-SE 90 350 32.7 11.4 1905 1714 166 525 33.3 17.5 2761 2485 158 700 33.9 23.7 3628 3265 153 900 34.5 31.0 4551 4096 147 1400 36.0 50.4 6845 6161 136 2000 37.5 75.1 9456 8511 126 BXRC-40G4000-C-8x-SE 90 525 32.7 17.2 2848 2563 166 785 33.3 26.1 4116 3704 158 1050 33.9 35.6 5425 4883 153 1170 34.1 39.9 5959 5363 149 2100 36.0 75.5 10236 9212 135 3000 37.5 112.6 14140 12726 126 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-40G4000-D-8x-SE 90 425 27.2 11.6 1917 1725 166 650 27.7 18.0 2829 2546 157 850 28.2 23.9 3652 3287 153 1050 28.6 30.0 4414 3973 147 1700 29.9 50.9 6890 6201 135 2500 31.3 78.3 9768 8791 125 BXRE-40H4000-B-8x-SE 97 typ. 350 32.7 11.4 1701 1531 149 525 33.3 17.5 2467 2220 141 700 33.9 23.7 3241 2917 137 900 34.5 31 4066 3659 131 1400 36 50.4 6115 5504 121 2000 37.5 75.1 8448 7603 112 BXRC-50C4001-B-8x-SE 70 350 32.7 11.4 2400 2160 210 525 33.3 17.5 3479 3131 199 700 33.9 23.7 4572 4115 193 900 34.5 31.0 5736 5162 185 1400 36.0 50.4 8627 7764 171 2000 37.5 75.1 11918 10726 159 BXRC-50C4001-C-8x-SE 70 525 32.7 17.2 3589 3230 209 785 33.3 26.1 5187 4669 199 1050 33.9 35.6 6837 6153 192 1170 34.1 39.9 7510 6759 188 2100 36.0 75.5 12900 11610 171 3000 37.5 112.6 17821 16039 158 BXRC-50C4001-D-8x-SE 70 425 27.2 11.6 2416 2174 209 650 27.7 18.0 3565 3209 198 850 28.2 23.9 4602 4142 192 1050 28.6 30.0 5563 5007 185 1700 29.9 50.9 8683 7815 171 2500 31.3 78.3 12310 11079 157 BXRC-50E4001-B-8x-SE 80 350 32.7 11.4 2309 2078 202 525 33.3 17.5 3347 3012 192 700 33.9 23.7 4398 3958 186 900 34.5 31.0 5518 4966 178 1400 36.0 50.4 8299 7469 165 2000 37.5 75.1 11464 10318 153 BXRC-50E4001-C-8x-SE 80 525 32.7 17.2 3453 3107 201 785 33.3 26.1 4990 4491 191 1050 33.9 35.6 6577 5919 185 1170 34.1 39.9 7224 6502 181 2100 36.0 75.5 12409 11168 164 3000 37.5 112.6 17143 15428 152 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-50E4001-D-8x-SE 80 425 27.2 11.6 2324 2092 201 650 27.7 18.0 3430 3087 190 850 28.2 23.9 4427 3984 185 1050 28.6 30.0 5351 4816 178 1700 29.9 50.9 8353 7518 164 2500 31.3 78.3 11841 10657 151 BXRC-50G4001-B-8x-SE 90 350 32.7 11.4 1996 1796 174 525 33.3 17.5 2893 2604 166 700 33.9 23.7 3802 3422 160 900 34.5 31.0 4770 4293 154 1400 36.0 50.4 7173 6456 142 2000 37.5 75.1 9910 8919 132 BXRC-50G4001-C-8x-SE 90 525 32.7 17.2 2984 2686 174 785 33.3 26.1 4313 3882 165 1050 33.9 35.6 5685 5117 160 1170 34.1 39.9 6244 5620 156 2100 36.0 75.5 10726 9654 142 3000 37.5 112.6 14818 13336 132 BXRC-50G4001-D-8x-SE 90 425 27.2 11.6 2009 1808 174 650 27.7 18.0 2965 2668 165 850 28.2 23.9 3827 3444 160 1050 28.6 30.0 4626 4163 154 1700 29.9 50.9 7220 6498 142 2500 31.3 78.3 10236 9212 131 BXRC-57C4001-B-8x-SE 70 350 32.7 11.4 2335 2102 204 525 33.3 17.5 3385 3046 194 700 33.9 23.7 4448 4003 188 900 34.5 31.0 5580 5022 180 1400 36.0 50.4 8392 7553 167 2000 37.5 75.1 11594 10434 154 BXRC-57C4001-C-8x-SE 70 525 32.7 17.2 3492 3142 203 785 33.3 26.1 5046 4542 193 1050 33.9 35.6 6651 5986 187 1170 34.1 39.9 7306 6575 183 2100 36.0 75.5 12549 11294 166 3000 37.5 112.6 17336 15603 154 BXRC-57C4001-D-8x-SE 70 425 27.2 11.6 2350 2115 203 650 27.7 18.0 3469 3122 193 850 28.2 23.9 4477 4029 187 1050 28.6 30.0 5412 4871 180 1700 29.9 50.9 8447 7602 166 2500 31.3 78.3 11975 10778 153 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-57E4001-B-8x-SE 80 350 32.7 11.4 2218 1996 194 525 33.3 17.5 3215 2893 184 700 33.9 23.7 4224 3802 178 900 34.5 31.0 5299 4770 171 1400 36.0 50.4 7970 7173 158 2000 37.5 75.1 11011 9910 147 BXRC-57E4001-C-8x-SE 80 525 32.7 17.2 3316 2984 193 785 33.3 26.1 4793 4313 183 1050 33.9 35.6 6317 5685 178 1170 34.1 39.9 6938 6244 174 2100 36.0 75.5 11918 10726 158 3000 37.5 112.6 16465 14818 146 BXRC-57E4001-D-8x-SE 80 425 27.2 11.6 2232 2009 193 650 27.7 18.0 3294 2965 183 850 28.2 23.9 4252 3827 178 1050 28.6 30.0 5140 4626 171 1700 29.9 50.9 8022 7220 158 2500 31.3 78.3 11373 10236 145 BXRC-65C4001-B-8x-SE 70 350 32.7 11.4 2335 2102 204 525 33.3 17.5 3385 3046 194 700 33.9 23.7 4448 4003 188 900 34.5 31.0 5580 5022 180 1400 36.0 50.4 8392 7553 167 2000 37.5 75.1 11594 10434 154 BXRC-65C4001-C-8x-SE 70 525 32.7 17.2 3492 3142 203 785 33.3 26.1 5046 4542 193 1050 33.9 35.6 6651 5986 187 1170 34.1 39.9 7306 6575 183 2100 36.0 75.5 12549 11294 166 3000 37.5 112.6 17336 15603 154 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-65C4001-D-8x-SE 70 425 27.2 11.6 2350 2115 203 650 27.7 18.0 3469 3122 193 850 28.2 23.9 4477 4029 187 1050 28.6 30.0 5412 4871 180 1700 29.9 50.9 8447 7602 166 2500 31.3 78.3 11975 10778 153 BXRC-65E4001-B-8x-SE 80 350 32.7 11.4 2244 2019 196 525 33.3 17.5 3252 2927 186 700 33.9 23.7 4274 3847 180 900 34.5 31.0 5362 4826 173 1400 36.0 50.4 8064 7258 160 2000 37.5 75.1 11140 10026 148 BXRC-65E4001-C-8x-SE 80 525 32.7 17.2 3355 3020 196 785 33.3 26.1 4849 4364 186 1050 33.9 35.6 6391 5752 180 1170 34.1 39.9 7020 6318 176 2100 36.0 75.5 12058 10853 160 3000 37.5 112.6 16658 14993 148 BXRC-65E4001-D-8x-SE 80 425 27.2 11.6 2258 2033 195 650 27.7 18.0 3333 3000 185 850 28.2 23.9 4302 3872 180 1050 28.6 30.0 5200 4680 173 1700 29.9 50.9 8117 7305 160 2500 31.3 78.3 11507 10356 147 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Electrical Characteristics
Table 5: Electrical Characteristics Part Number Drive Current (mA) Forward Voltage Pulsed, Tc = 25ºC (V) 1, 2, 3, 8 Typical Coefficient of Forward Voltage4 ∆Vf/∆Tc (mV/ºC) Typical Thermal Resistance Junction to Case5,6 Rj-c (ºC/W) Driver Selection Voltages7 (V) Minimum Typical Maximum Vf Min. Hot Tc = 105ºC (V) Vf Max. Cold Tc = -40ºC (V) BXRC-xxx400x-B-8x-SE BXRC-xxx400x-C-8x-SE BXRC-xxx400x-D-8x-SE Notes for Table 5: 1. Parts are tested in pulsed conditions, Tc = 25°C. Pulse width is 10ms. 2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance. 3. Bridgelux maintains a tester tolerance of ± 0.10V on forward voltage measurements. 4. Typical coefficient of forward voltage tolerance is ± 0.1mV for nominal current. 5. Thermal resistance values are based from test data of a 3000K 80 CRI product. 6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal interface material used during testing is not included in the thermal resistance value. 7. Vf min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design and selection over the operating range of the product. 8. This product has been designed and manufactured per IEC 62031:2018. This product has passed dielectric withstand voltage testing at 1140 V. The working voltage designated for the insulation is 70V d.c. The maximum allowable voltage across the array must be determined in the end product application.
Table 6: Eye Safety Risk Group (RG) Classifications Part Number Drive Current (mA) CCT 2700K/3000K 4000K2 5000K3 6500K4 BXRC-xxx400x-B-8x-SE
1440 RG1 RG1 RG1 RG1
2000 RG1 RG1 RG1 RG2
1995 RG1 RG1 RG1 RG2
2650 RG1 RG1 RG2 RG2
3000 RG1 RG2 RG2 RG2
1730 RG1 RG1 RG1 RG1
2400 RG1 RG1 RG1 RG2
2500 RG1 RG1 RG2 RG2
Notes for Table 6: 1. Eye safety classification for the use of Bridgelux Vero Series LED arrays is in accordance with specification IEC/TR 62778: Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires. 2. For products classified as RG2 at 4000K, Ethr= 1980 lx. 3. For products classified as RG2 at 5000K Ethr= 1530 lx. 4. For products classified as RG2 at 6500K, Ethr= 1170 lx. 5. Please contact your Bridgelux sales representative for Ethr values at specific drive currents and CCTs not listed.
LED Junction Temperature (Tj) 150°C Storage Temperature -40°C to +105°C Operating Case Temperature1 (Tc) 105°C Soldering Temperature2 300°C or lower for a maximum of 6 seconds BXRC-xxx400x-B-8x-SE BXRC-xxx400x-C-8x-SE BXRC-xxx400x-D-8x-SE Maximum Drive Current3 2000 mA 3000 mA 2500 mA Maximum Peak Pulsed Drive Current4 2240 mA 3360 mA 2800 mA Maximum Reverse Voltage5 -60V -60V -50V Notes for Table 7: 1. For IEC 62717 requirement, please consult your Bridgelux sales representative. 2. Refer to Bridgelux Application Note AN120: Bridgelux Vero SE Array Design Guide. 3. Arrays may be driven at higher currents however lumen maintenance may be reduced and warranty will not apply. 4. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed current specified. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures. 5. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating provided for reference only. Table 7: Maximum Ratings
Figure 13: Typical Color Spectrum Notes for Figure 13: 1. Color spectra measured at nominal current for Tj = Tc = 25°C. 2. Color spectra shown is 3000K and 80 CRI. 3. Color spectra shown is 4000K and 80 CRI. 4. Color spectra shown is 5000K and 70 CRI. 4. Color spectra shown is 6500K and 70 CRI. 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 110% 400 450 500 550 600 650 700 750 800 Relative Spectral Power Distribution Wavelength (nm) 3000K 4000K 5000K 6500K
Figure 14: Drawing for Vero SE 18 LED Array Notes for Figure 14: 1. Drawings are not to scale. 2. Drawing dimensions are in millimeters. 3. Unless otherwise specified, tolerances are ±0.15 mm. 4. Mounting holes (2X) are for M3 screws. 5. Bridgelux recommends two tapped holes for mounting screws with 31.3 ± 0.10mm center-to-center spacing. 6. Screws with flat shoulders (pan, dome, button, round, truss, mushroom) provide optimal torque control. Do NOT use flat, countersink, or raised head screws. 7. The optical center of the LED Array is nominally defined by the mechanical center of the array to a tolerance of ± 0.2mm. 8. Bridgelux maintains a flatness of 0.10mm across the mounting surface of the array
Figure 15: Warm and Neutral White Test Bins in xy Color Space Figure 16: Cool White Test Bins in xy Color Space Color Binning Information Bin Code 2700K 3000K 3500K 4000K ANSI Bin (for reference only) (2580K - 2870K) (2870K - 3220K) (3220K - 3710K) (3710K - 4260K) 83 (3 SDCM) (2651K - 2794K) (2968K - 3136K) (3369K - 3586K) (3851K - 4130K) 82 (2 SDCM) (2674K - 2769K) (2995K - 3107K) (3404K - 3548K) (3895K - 4081K) Table 8: Warm and Neutral White xy Bin Coordinates and Associated Typical CCT Bin Code 5000K 5700K 6500K ANSI Bin (for reference only) (4745K - 5311K) (5312K - 6022K) (6022K - 7042K) 84 (4 SDCM) (4801K - 5282K) (5395K- 5970K) (6200K - 6910K) 83 (3 SDCM) (4835K-5215K) (5460K- 5891K) (6279K -6811K) Table 9: Cool White xy Bin Coordinates and Associated Typical CCT (product is hot targeted to Tc = 85°C) Note: Pulsed Test Conditions, Tc = 25°C Note: Pulsed Test Conditions, Tc = 25°C 0.3 0.31 0.32 0.33 0.34 0.35 0.36 0.37 0.38 0.39 Y X
4 SDCM
3 SDCM
0.34 0.36 0.38 0.4 0.42 0.44 Y X
2 SDCM
Note for Tables 8-9: 1. Bridgelux maintains a tolerance of +/- 0.007 on x and y color coordinates in the CIE 1931 color Space.
Figure 17: Drawing for Vero SE 18 Packaging Tray Notes for Figure 17: 1. Dimensions are in millimeters. 2. Drawings are not to scale.
Bridgelux has developed a comprehensive set of application notes and design resources to assist customers in successfully designing with the Vero product family of LED array products. For all available application notes visit www.bridgelux.com. Optical Source Models Optical source models and ray set files are available for all Bridgelux products. For a list of available formats, visit www.bridgelux.com. MINOR PRODUCT CHANGE POLICY The rigorous qualification testing on products offered by Bridgelux provides performance assurance. Slight cos- metic changes that do not affect form, fit, or function may occur as Bridgelux continues product optimization. CAUTION: CHEMICAL EXPOSURE HAZARD Exposure to some chemicals commonly used in luminaire manufacturing and assembly can cause damage to the LED array. Please consult Bridgelux CAUTION: RISK OF BURN Do not touch the Vero LED array during operation. Allow the array to cool for a sufficient period of time before handling. The Vero LED array may reach elevated temperatures such that could burn skin when touched. 3D CAD Models Three dimensional CAD models depicting the product outline of all Bridgelux Vero LED arrays are available in both IGS and STEP formats. Please contact your Bridgelux sales representative for assistance. LM80 LM80 testing has been completed and the LM80 report is now available. Please contact your Bridgelux sales representative for LM-80 report. CAUTION CONTACT WITH LIGHT EMITTING SURFACE (LES) Avoid any contact with the LES. Do not touch the LES of the LED array or apply stress to the LES (yellow phosphor resin area). Contact may cause damage to the LED array. Optics and reflectors must not be mounted in contact with the LES (yellow phosphor resin area). Optical devices may be mounted on the top surface of the plas- tic housing of the Vero LED array. Use the mechanical features of the LED array housing, edges and/or mounting holes to locate and secure optical devices as needed. STANDARD TEST CONDITIONS Unless otherwise stated, array testing is performed at the nominal drive current.
About Bridgelux: Bridging Light and Life™ © 2023 Bridgelux, Inc. All rights reserved. Product specifications are subject to change without notice. Bridgelux, the Bridgelux stylized logo design, Vero, V Series and V Series HD are registered trademarks, and Decor Series is a trademark of Bridgelux, Inc. All other trademarks are the property of their respective owners. Bridgelux Gen 8 Vero SE 18 Array Series Product Data Sheet DS432 Rev. E (07/2023)
46410 Fremont Boulevard
Fremont, CA 94538 U.S.A. Tel (925) 583-8400 www.bridgelux.com At Bridgelux, we help companies, industries and people experience the power and possibility of light. Since 2002, we’ve designed LED solutions that are high performing, energy efficient, cost effective and easy to integrate. Our focus is on light’s impact on human behavior, deliver- ing products that create better environments, experiences and returns—both experiential and financial. And our patented technology drives new platforms for commercial and industrial luminaires. For more information about the company, please visit bridgelux.com twitter.com/Bridgelux facebook.com/Bridgelux youtube.com/user/Bridgelux linkedin.com/company/bridgelux-inc-_2 WeChat ID: BridgeluxInChina