The Vero® SE Series is a revolutionary light source system that integrates Bridgelux’s eighth generation COB technology with poke-in connectivity, enabling solder-free installation. Vero SE LED light sources streamline assembly processes, lower manufacturing costs, simplify the luminaire design process, improve light quality, and increase design flexibility. Vero SE is available in four different light emitting surface (LES) configurations that operate reliably over a broad current range. With Vero SE, secondary connector and holder components are not required, allowing for rapid integration of arrays into fixtures, and an efficient field replaceable solution. Vero SE arrays deliver increased lumen density for improved beam control and precision lighting, with 2 and 3 SDCM color control standards for clean and consistent uniform lighting. Vero SE

Features

  • Poke-in electrical connectivity
  • Top side part number markings
  • Efficacy of 173 lm/W typical, 3000K 80 CRI
  • Reliable operation at up to 3x nominal current, 30% increase in maximum lumens per LES size
  • Wide selection of CCT options (2700K-6500K) with minimum 70, 80 and 90 CRI options
  • Uniform high-quality illumination
  • 2 and 3 SDCM binning options (2700K – 4000K)
  • Forward voltage bin codes (backside marking)
  • 10-Year warranty Benefits
  • Low cost, solderless, connector free installation and field upgradability
  • Improved inventory management and quality control
  • Enables high efficiency lighting systems and lower operating costs
  • Supports the trend toward luminaire miniaturization and delivers enhanced optical control
  • Design flexibility for a broad range of lighting applica- tions
  • Clean white light without pixelation
  • Uniform consistent white light
  • Design flexibility for multi-source applications
  • Design with confidence

The part number designation for Bridgelux Vero SE LED arrays is explained as follows: 1 2 3 4 – 5 6 7 8 9 10 11 – 12 – 13 14 – 15 16 Product Family CCT Bin Options 2 = 2 SDCM 3 = 3 SDCM 4 = 4 SDCM CRI C = 70 CRI min. E = 80 CRI min. G = 90 CRI min. H = 97 CRI typ. Array Configuration 27 = 2,700K 30 = 3,000K 35 = 3,500K 40 = 4,000K 50 = 5,000K 57 = 5,700K 65 = 6,500K BXRC – 30 E 100 0 – C – 8 3 – SE Color Targeting Designator 0 = Cold Targeted 1 = Hot Targeted C = Decor Series Showcase Gen. 8 Nominal CCT Flux Indicator 100x = 1000 lm Vero SE 10 is the smallest form factor in the product family of next generation solid state light sources. In addition to delivering the performance and light quality required for many lighting applications, Vero SE incorporates several features to simplify the design integration and manufacturing process, accelerate time to market and reduce system costs. Please visit www. bridgelux.com for more information on the Vero SE family of products. Special Edition Mounting holes Polarity indication marks simplify manufacturing operator instructions 2D Bar code provides full manufacturing traceability Tc Measurement point Radial die configuration improves lumen density and beam control Optic mounting holes Wire release mechanisms (x4) Dual poke-in connectivity Top side part number marking improves inventory management and outgoing quality control Test ports for probing

The following product configurations are available: Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-27E1000-B-8x-SE 2700 80 200 1113 980 34.2 6.8 163 BXRC-27E1000-C-8x-SE 2700 80 300 1501 1321 30.7 9.2 163 BXRC-27E1000-D-8x-SE 2700 80 250 1014 892 24.9 6.2 163 BXRC-27G1000-B-8x-SE 2700 90 200 919 808 34.2 6.8 134 BXRC-27G1000-C-8x-SE 2700 90 300 1239 1090 30.7 9.2 134 BXRC-27G1000-D-8x-SE 2700 90 250 836 736 24.9 6.2 134 BXRC-27G10H0-B-8x-SE 2700 90 200 958 843 34.2 6.8 140 BXRC-27G10H0-C-8x-SE 2700 90 300 1292 1137 30.7 9.2 140 BXRC-27G10H0-D-8x-SE 2700 90 250 872 768 24.9 6.2 140 BXRC-27H1000-B-8x-SE 2700 97 200 814 716 34.2 6.8 119 BXRC-27H1000-C-8x-SE 2700 97 300 1098 966 30.7 9.2 119 BXRC-27H1000-D-8x-SE 2700 97 250 741 652 24.9 6.2 119 BXRC-30C1001-B-8x-SE 3000 70 200 1239 1090 34.2 6.8 181 BXRC-30C1001-C-8x-SE 3000 70 300 1670 1470 30.7 9.2 181 BXRC-30C1001-D-8x-SE 3000 70 250 1128 992 24.9 6.2 181 BXRC-30E1000-B-8x-SE 3000 80 200 1183 1041 34.2 6.8 173 BXRC-30E1000-C-8x-SE 3000 80 300 1595 1404 30.7 9.2 173 BXRC-30E1000-D-8x-SE 3000 80 250 1077 948 24.9 6.2 173 BXRC-30G1000-B-8x-SE 3000 90 200 960 845 34.2 6.8 140 BXRC-30G1000-C-8x-SE 3000 90 300 1295 1139 30.7 9.2 141 BXRC-30G1000-D-8x-SE 3000 90 250 874 769 24.9 6.2 140 BXRC-30G10H0-B-8x-SE 3000 90 200 1005 885 34.2 6.8 147 BXRC-30G10H0-C-8x-SE 3000 90 300 1356 1193 30.7 9.2 147 BXRC-30G10H0-D-8x-SE 3000 90 250 915 806 24.9 6.2 147 BXRC-30H1000-B-8x-SE 3000 97 200 870 765 34.2 6.8 127 BXRC-30H1000-C-8x-SE 3000 97 300 1173 1032 30.7 9.2 127 BXRC-30H1000-D-8x-SE 3000 97 250 792 697 24.9 6.2 127 BXRC-35E1000-B-8x-SE 3500 80 200 1211 1065 34.2 6.8 177 BXRC-35E1000-C-8x-SE 3500 80 300 1633 1437 30.7 9.2 177 BXRC-35E1000-D-8x-SE 3500 80 250 1102 970 24.9 6.2 177 BXRC-35G1000-B-8x-SE 3500 90 200 995 876 34.2 6.8 145 BXRC-35G1000-C-8x-SE 3500 90 300 1342 1181 30.7 9.2 146 BXRC-35G1000-D-8x-SE 3500 90 250 906 797 24.9 6.2 146 BXRC-40C1001-B-8x-SE 4000 70 200 1273 1121 34.2 6.8 186 BXRC-40C1001-C-8x-SE 4000 70 300 1717 1511 30.7 9.2 186 BXRC-40C1001-D-8x-SE 4000 70 250 1159 1020 24.9 6.2 186 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are minimums for all products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance.

Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-40E1000-B-8x-SE 4000 80 200 1218 1072 34.2 6.8 178 BXRC-40E1000-C-8x-SE 4000 80 300 1642 1445 30.7 9.2 178 BXRC-40E1000-D-8x-SE 4000 80 250 1109 976 24.9 6.2 178 BXRC-40G1000-B-8x-SE 4000 90 200 1016 894 34.2 6.8 149 BXRC-40G1000-C-8x-SE 4000 90 300 1370 1205 30.7 9.2 149 BXRC-40G1000-D-8x-SE 4000 90 250 925 814 24.9 6.2 149 BXRC-50C1001-B-8x-SE 5000 70 200 1280 1127 34.2 6.8 187 BXRC-50C1001-C-8x-SE 5000 70 300 1726 1519 30.7 9.2 187 BXRC-50C1001-D-8x-SE 5000 70 250 1166 1026 24.9 6.2 187 BXRC-50E1001-B-8x-SE 5000 80 200 1232 1084 34.2 6.8 180 BXRC-50E1001-C-8x-SE 5000 80 300 1661 1461 30.7 9.2 180 BXRC-50E1001-D-8x-SE 5000 80 250 1121 987 24.9 6.2 180 BXRC-50G1001-B-8x-SE 5000 90 200 1065 937 34.2 6.8 156 BXRC-50G1001-C-8x-SE 5000 90 300 1436 1263 30.7 9.2 156 BXRC-50G1001-D-8x-SE 5000 90 250 969 853 24.9 6.2 156 BXRC-57C1001-B-8x-SE 5700 70 200 1246 1096 34.2 6.8 182 BXRC-57C1001-C-8x-SE 5700 70 300 1679 1478 30.7 9.2 182 BXRC-57C1001-D-8x-SE 5700 70 250 1134 998 24.9 6.2 182 BXRC-57E1001-B-8x-SE 5700 80 200 1183 1041 34.2 6.8 173 BXRC-57E1001-C-8x-SE 5700 80 300 1595 1404 30.7 9.2 173 BXRC-57E1001-D-8x-SE 5700 80 250 1077 948 24.9 6.2 173 BXRC-65C1001-B-8x-SE 6500 70 200 1246 1096 34.2 6.8 182 BXRC-65C1001-C-8x-SE 6500 70 300 1679 1478 30.7 9.2 182 BXRC-65C1001-D-8x-SE 6500 70 250 1134 998 24.9 6.2 182 BXRC-65E1001-B-8x-SE 6500 80 200 1197 1053 34.2 6.8 175 BXRC-65E1001-C-8x-SE 6500 80 300 1614 1420 30.7 9.2 175 BXRC-65E1001-D-8x-SE 6500 80 250 1090 959 24.9 6.2 175 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are minimums for all products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test.

Table 2: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-27E1000-B-8x-SE 2700 80 200 1002 882 33.6 6.7 149 BXRC-27E1000-C-8x-SE 2700 80 300 1351 1189 30.1 9.0 150 BXRC-27E1000-D-8x-SE 2700 80 250 912 803 24.4 6.1 149 BXRC-27G1000-B-8x-SE 2700 90 200 827 727 33.6 6.7 123 BXRC-27G1000-C-8x-SE 2700 90 300 1115 981 30.1 9.0 123 BXRC-27G1000-D-8x-SE 2700 90 250 753 662 24.4 6.1 123 BXRC-27G10H0-B-8x-SE 2700 90 200 862 759 33.6 6.7 129 BXRC-27G10H0-C-8x-SE 2700 90 300 1163 1023 30.1 9.0 129 BXRC-27G10H0-D-8x-SE 2700 90 250 785 691 24.4 6.1 129 BXRC-27H1000-B-8x-SE 2700 97 200 733 645 33.6 6.7 109 BXRC-27H1000-C-8x-SE 2700 97 300 988 869 30.1 9.0 109 BXRC-27H1000-D-8x-SE 2700 97 250 667 587 24.4 6.1 109 BXRC-30C1001-B-8x-SE 3000 70 200 1115 981 33.6 6.7 166 BXRC-30C1001-C-8x-SE 3000 70 300 1503 1323 30.1 9.0 166 BXRC-30C1001-D-8x-SE 3000 70 250 1015 893 24.4 6.1 166 BXRC-30E1000-B-8x-SE 3000 80 200 1065 937 33.6 6.7 159 BXRC-30E1000-C-8x-SE 3000 80 300 1436 1263 30.1 9.0 159 BXRC-30E1000-D-8x-SE 3000 80 250 969 853 24.4 6.1 159 BXRC-30G1000-B-8x-SE 3000 90 200 864 761 33.6 6.7 129 BXRC-30G1000-C-8x-SE 3000 90 300 1165 1025 30.1 9.0 129 BXRC-30G1000-D-8x-SE 3000 90 250 787 692 24.4 6.1 129 BXRC-30G10H0-B-8x-SE 3000 90 200 905 796 33.6 6.7 135 BXRC-30G10H0-C-8x-SE 3000 90 300 1220 1074 30.1 9.0 135 BXRC-30G10H0-D-8x-SE 3000 90 250 824 725 24.4 6.1 135 BXRC-30H1000-B-8x-SE 3000 97 200 783 689 33.6 6.7 117 BXRC-30H1000-C-8x-SE 3000 97 300 1056 929 30.1 9.0 117 BXRC-30H1000-D-8x-SE 3000 97 250 713 627 24.4 6.1 117 BXRC-35E1000-B-8x-SE 3500 80 200 1090 959 33.6 6.7 162 BXRC-35E1000-C-8x-SE 3500 80 300 1469 1293 30.1 9.0 163 BXRC-35E1000-D-8x-SE 3500 80 250 992 873 24.4 6.1 162 BXRC-35G1000-B-8x-SE 3500 90 200 896 788 33.6 6.7 133 BXRC-35G1000-C-8x-SE 3500 90 300 1208 1063 30.1 9.0 134 BXRC-35G1000-D-8x-SE 3500 90 250 815 717 24.4 6.1 134 BXRC-40C1001-B-8x-SE 4000 70 200 1146 1009 33.6 6.7 171 BXRC-40C1001-C-8x-SE 4000 70 300 1545 1360 30.1 9.0 171 BXRC-40C1001-D-8x-SE 4000 70 250 1043 918 24.4 6.1 171 Notes for Table 2: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are minimums for all products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.

Table 2: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-40E1000-B-8x-SE 4000 80 200 1096 964 33.6 6.7 163 BXRC-40E1000-C-8x-SE 4000 80 300 1478 1300 30.1 9.0 164 BXRC-40E1000-D-8x-SE 4000 80 250 998 878 24.4 6.1 163 BXRC-40G1000-B-8x-SE 4000 90 200 914 805 33.6 6.7 136 BXRC-40G1000-C-8x-SE 4000 90 300 1233 1085 30.1 9.0 136 BXRC-40G1000-D-8x-SE 4000 90 250 832 733 24.4 6.1 136 BXRC-50C1001-B-8x-SE 5000 70 200 1152 1014 33.6 6.7 172 BXRC-50C1001-C-8x-SE 5000 70 300 1554 1367 30.1 9.0 172 BXRC-50C1001-D-8x-SE 5000 70 250 1049 923 24.4 6.1 172 BXRC-50E1001-B-8x-SE 5000 80 200 1108 975 33.6 6.7 165 BXRC-50E1001-C-8x-SE 5000 80 300 1495 1315 30.1 9.0 165 BXRC-50E1001-D-8x-SE 5000 80 250 1009 888 24.4 6.1 165 BXRC-50G1001-B-8x-SE 5000 90 200 958 843 33.6 6.7 143 BXRC-50G1001-C-8x-SE 5000 90 300 1292 1137 30.1 9.0 143 BXRC-50G1001-D-8x-SE 5000 90 250 872 768 24.4 6.1 143 BXRC-57C1001-B-8x-SE 5700 70 200 1121 986 33.6 6.7 167 BXRC-57C1001-C-8x-SE 5700 70 300 1512 1330 30.1 9.0 167 BXRC-57C1001-D-8x-SE 5700 70 250 1021 898 24.4 6.1 167 BXRC-57E1001-B-8x-SE 5700 80 200 1065 937 33.6 6.7 159 BXRC-57E1001-C-8x-SE 5700 80 300 1436 1263 30.1 9.0 159 BXRC-57E1001-D-8x-SE 5700 80 250 969 853 24.4 6.1 159 BXRC-65C1001-B-8x-SE 6500 70 200 1121 986 33.6 6.7 167 BXRC-65C1001-C-8x-SE 6500 70 300 1512 1330 30.1 9.0 167 BXRC-65C1001-D-8x-SE 6500 70 250 1021 898 24.4 6.1 167 BXRC-65E1001-B-8x-SE 6500 80 200 1077 948 33.6 6.7 161 BXRC-65E1001-C-8x-SE 6500 80 300 1452 1278 30.1 9.0 161 BXRC-65E1001-D-8x-SE 6500 80 250 981 863 24.4 6.1 161 Notes for Table 2: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are minimums for all products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50,the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.

European Product Registry for Energy Labeling The European Product Registry for Energy Labeling (EPREL) is defined in the EU Regulation 2017/1369 to provide import- ant energy efficiency information to consumers. Together with Energy Labeling Regulation ELR (EU) 2019/2015 which was amended by regulation (EU) 2021/340 for energy labelling of light sources, manufacturers are required to declare an ener- gy class based on key technical specifications from each of their product and register it in an open data base managed by EPREL It is now a legal requirement for a vendor of light sources to upload information about their products into the EPREL database before placing these products on the market in the EU. Table 3 below provides a list of part numbers that are in compliance with ELR and are currently listed in the EPREL data- base. At Bridgelux, we are fully committed to supplying products that are compliant with pertinent laws, rules, and obligation imposed by relevant government bodies including the European Energy Labeling regulation. Customers can use these products with full confidence for any projects that fall under the ELR. Table 3: Part numbers registered in European Product Registry for Energy Labeling PART NUMBER1 CCT (K) CRI Current2 (mA) Vf (V) Useful flux3 (Φuse) at 85C (lm) Pow- er (W) Efficacy (lm/W) Energy efficiency class4 Regis- tration No URL to Product Information Sheet in EPREL Database Notes for Table 3: 1. All device listed here must be disposed as e-waste upon its end of life according to local country guideline in each country. 2. For information on performance values at alternative drive conditions. please refer to the Product Selection Guide, Absolute Maximum Rating Table and Performance Curves in this data sheet. 3. For a definition of useful luminous flux (ΦΦuse), please see the ELR regulations at https:/ /tinyurl.com/4b6zvt4m. 4. EPREL requires an arrow symbol containing the letter of the energy efficiency class to be displayed. on technical promotional material. Refer to this energy efficiency class column for specific energy efficiency class on each part number.

European Product Registry for Energy Labeling Table 3: Part numbers registered in European Product Registry for Energy Labeling (Continued) PART NUMBER1 CCT (K) CRI Current2 (mA) Vf (V) Useful flux (Φuse) at 85C (lm) Pow- er (W) Efficacy (lm/W) Energy efficiency class3 Regis- tration No URL to Product Information Sheet in EPREL Database Notes for Table 3: 1. All device listed here must be disposed as e-waste upon its end of life according to local country guideline in each country. 2. For information on performance values at alternative drive conditions. please refer to the Product Selection Guide, Absolute Maximum Rating Table and Performance Curves in this data sheet. 3. For a definition of useful luminous flux (ΦΦuse), please see the ELR regulations at https:/ /tinyurl.com/4b6zvt4m. 4. EPREL requires an arrow symbol containing the letter of the energy efficiency class to be displayed. on technical promotional material. Refer to this energy efficiency class column for specific energy efficiency class on each part number.

European Product Registry for Energy Labeling Table 3: Part numbers registered in European Product Registry for Energy Labeling (Continued) PART NUMBER1 CCT (K) CRI Current2 (mA) Vf (V) Useful flux (Φuse) at 85C (lm) Pow- er (W) Efficacy (lm/W) Energy efficiency class3 Regis- tration No URL to Product Information Sheet in EPREL Database Notes for Table 3: 1. All device listed here must be disposed as e-waste upon its end of life according to local country guideline in each country. 2. For information on performance values at alternative drive conditions. please refer to the Product Selection Guide, Absolute Maximum Rating Table and Performance Curves in this data sheet. 3. For a definition of useful luminous flux (ΦΦuse), please see the ELR regulations at https:/ /tinyurl.com/4b6zvt4m. 4. EPREL requires an arrow symbol containing the letter of the energy efficiency class to be displayed. on technical promotional material. Refer to this energy efficiency class column for specific energy efficiency class on each part number.

Performance at Commonly Used Drive Currents Vero LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. Vero SE may also be driven at other drive currents dependent on specific application design requirements. The performance at any drive current can be derived from the current vs. voltage characteristics shown in Figures 1, 2 & 3 and the flux vs. current characteristics shown in Figures 4, 5 & 6. The performance at commonly used drive currents is summarized in Table 4. Table 4: Product Performance at Commonly Used Drive Currents Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-27E1000-B-8x-SE 80 100 32.9 3.3 580 522 176 150 33.6 5.0 848 763 168 200 34.2 6.8 1113 1002 163 270 35.0 9.5 1458 1312 154 400 36.5 14.6 2071 1864 142 500 37.5 18.7 2509 2258 134 BXRC-27E1000-C-8x-SE 80 150 29.6 4.4 783 704 176 225 30.2 6.8 1143 1028 168 300 30.7 9.2 1501 1351 163 360 31.2 11.2 1766 1589 157 600 32.8 19.7 2793 2514 142 1000 35.0 35.0 4277 3849 122 BXRC-27E1000-D-8x-SE 80 125 24.0 3.0 528 476 176 185 24.4 4.5 762 686 169 250 24.9 6.2 1014 912 163 350 25.6 9.0 1372 1235 153 500 26.6 13.3 1886 1697 142 1000 29.1 29.1 3316 2984 114 BXRC-27G1000-B-8x-SE 90 100 32.9 3.3 479 431 146 150 33.6 5.0 699 629 139 200 34.2 6.8 919 827 134 270 35.0 9.5 1203 1083 127 400 36.5 14.6 1709 1538 117 500 37.5 18.7 2070 1863 110 BXRC-27G1000-C-8x-SE 90 150 29.6 4.4 646 581 146 225 30.2 6.8 943 849 139 300 30.7 9.2 1239 1115 134 360 31.2 11.2 1457 1311 130 600 32.8 19.7 2304 2074 117 1000 35.0 35.0 3528 3175 101 BXRC-27G1000-D-8x-SE 90 125 24.0 3.0 436 392 146 185 24.4 4.5 629 566 139 250 24.9 6.2 836 753 134 350 25.6 9.0 1132 1019 126 500 26.6 13.3 1556 1400 117 1000 29.1 29.1 2736 2462 94 Notes for Table 4: 1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-27G10H0-B-8x-SE 90 100 32.9 3.3 499 450 152 150 33.6 5.0 729 656 145 200 34.2 6.8 958 862 140 270 35.0 9.5 1255 1130 133 400 36.5 14.6 1783 1604 122 500 37.5 18.7 2159 1943 115 BXRC-27G10H0-C-8x-SE 90 150 29.6 4.4 673 606 152 225 30.2 6.8 984 885 145 300 30.7 9.2 1292 1163 140 360 31.2 11.2 1520 1368 135 600 32.8 19.7 2404 2163 122 1000 35.0 35.0 3681 3313 105 BXRC-27G10H0-D-8x-SE 90 125 24.0 3.0 455 409 152 185 24.4 4.5 656 590 145 250 24.9 6.2 872 785 140 350 25.6 9.0 1181 1063 132 500 26.6 13.3 1623 1461 122 1000 29.1 29.1 2854 2568 98 BXRC-27H1000-B-8x-SE 97 100 32.9 3.3 424 382 129 150 33.6 5.0 620 558 123 200 34.2 6.8 814 733 119 270 35.0 9.5 1066 960 113 400 36.5 14.6 1515 1363 104 500 37.5 18.7 1835 1651 98 BXRC-27H1000-C-8x-SE 97 150 29.8 4.5 575 518 129 225 30.3 6.8 839 755 123 300 30.7 9.2 1098 988 119 360 31.1 11.2 1301 1171 116 600 32.4 19.4 2078 1870 107 1000 34.3 34.3 3250 2925 95 BXRC-27H1000-D-8x-SE 97 125 24.3 3.0 389 350 128 185 24.6 4.5 560 504 123 250 24.9 6.2 741 667 119 350 25.4 8.9 1014 913 114 500 26.1 13.0 1410 1269 108 1000 28.1 28.1 2601 2341 93 BXRC-30C1001-B-8x-SE 70 100 32.9 3.3 646 581 196 150 33.6 5.0 943 849 187 200 34.2 6.8 1239 1115 181 270 35.0 9.5 1622 1460 172 400 36.5 14.6 2305 2074 158 500 37.5 18.7 2791 2512 149 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Table 4: Product Performance at Commonly Used Drive Currents (Continued) Performance at Commonly Used Drive Currents Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-30C1001-C-8x-SE 70 150 29.8 4.5 875 787 196 225 30.3 6.8 1277 1149 187 300 30.7 9.2 1670 1503 181 360 31.1 11.2 1979 1781 177 600 32.4 19.4 3161 2845 163 1000 34.3 34.3 4944 4450 144 BXRC-30C1001-D-8x-SE 70 125 24.3 3.0 592 533 195 185 24.6 4.5 851 766 187 250 24.9 6.2 1128 1015 181 350 25.4 8.9 1543 1389 174 500 26.1 13.0 2144 1930 165 1000 28.1 28.1 3958 3562 141 BXRC-30E1000-B-8x-SE 80 100 32.9 3.3 617 555 187 150 33.6 5.0 900 810 179 200 34.2 6.8 1183 1065 173 270 35.0 9.5 1549 1394 164 400 36.5 14.6 2201 1981 151 500 37.5 18.7 2666 2399 142 BXRC-30E1000-C-8x-SE 80 150 29.8 4.5 836 752 187 225 30.3 6.8 1219 1097 179 300 30.7 9.2 1595 1436 173 360 31.1 11.2 1890 1701 169 600 32.4 19.4 3019 2717 155 1000 34.3 34.3 4722 4250 137 BXRC-30E1000-D-8x-SE 80 125 24.3 3.0 565 509 186 185 24.6 4.5 813 732 179 250 24.9 6.2 1077 969 173 350 25.4 8.9 1474 1326 166 500 26.1 13.0 2048 1843 157 1000 28.1 28.1 3780 3402 135 BXRC-30G1000-B-8x-SE 90 100 32.9 3.3 501 451 152 150 33.6 5.0 731 658 145 200 34.2 6.8 960 864 140 270 35.0 9.5 1258 1132 133 400 36.5 14.6 1787 1608 122 500 37.5 18.7 2164 1948 115 BXRC-30G1000-C-8x-SE 90 150 29.8 4.5 678 610 152 225 30.3 6.8 990 891 145 300 30.7 9.2 1295 1165 140 360 31.1 11.2 1534 1381 137 600 32.4 19.4 2451 2206 126 1000 34.3 34.3 3833 3450 112 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-30G1000-D-8x-SE 90 125 24.3 3.0 459 413 151 185 24.6 4.5 660 594 145 250 24.9 6.2 874 787 140 350 25.4 8.9 1196 1077 135 500 26.1 13.0 1663 1496 128 1000 28.1 28.1 3068 2761 109 BXRC-30G10H0-B-8x-SE 90 100 32.9 3.3 524 472 159 150 33.6 5.0 765 689 152 200 34.2 6.8 1005 905 147 270 35.0 9.5 1317 1185 139 400 36.5 14.6 1871 1684 128 500 37.5 18.7 2266 2039 121 BXRC-30G10H0-C-8x-SE 90 150 29.8 4.5 710 639 159 225 30.3 6.8 1036 933 152 300 30.7 9.2 1356 1220 147 360 31.1 11.2 1606 1446 144 600 32.4 19.4 2566 2310 132 1000 34.3 34.3 4014 3612 117 BXRC-30G10H0-D-8x-SE 90 125 24.3 3.0 480 432 158 185 24.6 4.5 691 622 152 250 24.9 6.2 915 824 147 350 25.4 8.9 1253 1127 141 500 26.1 13.0 1741 1567 134 1000 28.1 28.1 3213 2892 114 BXRC-30H1000-B-8x-SE 97 100 32.9 3.3 453 408 138 150 33.6 5.0 662 596 132 200 34.2 6.8 870 783 127 270 35.0 9.5 1139 1025 120 400 36.5 14.6 1618 1457 111 500 37.5 18.7 1960 1764 105 BXRC-30H1000-C-8x-SE 97 150 29.8 4.5 614 553 137 225 30.3 6.8 897 807 132 300 30.7 9.2 1173 1056 127 360 31.1 11.2 1390 1251 124 600 32.4 19.4 2220 1998 114 1000 34.3 34.3 3472 3125 101 BXRC-30H1000-D-8x-SE 97 125 24.3 3.0 416 374 137 185 24.6 4.5 598 538 131 250 24.9 6.2 792 713 127 350 25.4 8.9 1084 975 122 500 26.1 13.0 1506 1355 116 1000 28.1 28.1 2779 2501 99 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-35E1000-B-8x-SE 80 100 32.9 3.3 631 568 192 150 33.6 5.0 922 829 183 200 34.2 6.8 1211 1090 177 270 35.0 9.5 1586 1427 168 400 36.5 14.6 2253 2027 154 500 37.5 18.7 2728 2456 146 BXRC-35E1000-C-8x-SE 80 150 29.8 4.5 855 770 191 225 30.3 6.8 1248 1123 183 300 30.7 9.2 1633 1469 177 360 31.1 11.2 1934 1741 173 600 32.4 19.4 3090 2781 159 1000 34.3 34.3 4833 4350 141 BXRC-35E1000-D-8x-SE 80 125 24.3 3.0 578 521 191 185 24.6 4.5 832 749 183 250 24.9 6.2 1102 992 177 350 25.4 8.9 1509 1358 170 500 26.1 13.0 2096 1887 161 1000 28.1 28.1 3869 3482 138 BXRC-35G1000-B-8x-SE 90 100 32.9 3.3 519 467 158 150 33.6 5.0 757 682 150 200 34.2 6.8 995 896 146 270 35.0 9.5 1303 1173 138 400 36.5 14.6 1851 1666 127 500 37.5 18.7 2242 2018 120 BXRC-35G1000-C-8x-SE 90 150 29.8 4.5 703 633 157 225 30.3 6.8 1026 923 151 300 30.7 9.2 1342 1208 146 360 31.1 11.2 1590 1431 142 600 32.4 19.4 2540 2286 131 1000 34.3 34.3 3972 3575 116 BXRC-35G1000-D-8x-SE 90 125 24.3 3.0 475 428 157 185 24.6 4.5 684 615 150 250 24.9 6.2 906 815 146 350 25.4 8.9 1240 1116 140 500 26.1 13.0 1723 1551 132 1000 28.1 28.1 3179 2861 113 BXRC-40C1001-B-8x-SE 70 100 32.9 3.3 664 597 202 150 33.6 5.0 969 872 193 200 34.2 6.8 1273 1146 186 270 35.0 9.5 1668 1501 176 400 36.5 14.6 2369 2132 162 500 37.5 18.7 2870 2583 153 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-40C1001-C-8x-SE 70 150 29.8 4.5 899 810 201 225 30.3 6.8 1313 1181 193 300 30.7 9.2 1717 1545 186 360 31.1 11.2 2035 1831 182 600 32.4 19.4 3250 2925 167 1000 34.3 34.3 5083 4575 148 BXRC-40C1001-D-8x-SE 70 125 24.3 3.0 608 547 200 185 24.6 4.5 875 788 192 250 24.9 6.2 1159 1043 186 350 25.4 8.9 1587 1428 179 500 26.1 13.0 2205 1984 169 1000 28.1 28.1 4069 3662 145 BXRC-40E1000-B-8x-SE 80 100 32.9 3.3 635 571 193 150 33.6 5.0 927 834 184 200 34.2 6.8 1218 1096 178 270 35.0 9.5 1595 1435 169 400 36.5 14.6 2266 2039 155 500 37.5 18.7 2744 2470 146 BXRC-40E1000-C-8x-SE 80 150 29.8 4.5 860 774 192 225 30.3 6.8 1255 1130 184 300 30.7 9.2 1642 1478 178 360 31.1 11.2 1946 1751 174 600 32.4 19.4 3108 2797 160 1000 34.3 34.3 4861 4375 142 BXRC-40E1000-D-8x-SE 80 125 24.3 3.0 582 524 192 185 24.6 4.5 837 753 184 250 24.9 6.2 1109 998 178 350 25.4 8.9 1517 1365 171 500 26.1 13.0 2108 1897 162 1000 28.1 28.1 3891 3502 138 BXRC-40G1000-B-8x-SE 90 100 32.9 3.3 530 477 161 150 33.6 5.0 773 696 154 200 34.2 6.8 1016 914 149 270 35.0 9.5 1331 1198 141 400 36.5 14.6 1890 1701 130 500 37.5 18.7 2289 2060 122 BXRC-40G1000-C-8x-SE 90 150 29.8 4.5 718 646 160 225 30.3 6.8 1047 942 154 300 30.7 9.2 1370 1233 149 360 31.1 11.2 1623 1461 145 600 32.4 19.4 2593 2334 133 1000 34.3 34.3 4055 3650 118 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-40G1000-D-8x-SE 90 125 24.3 3.0 485 437 160 185 24.6 4.5 698 628 154 250 24.9 6.2 925 832 149 350 25.4 8.9 1266 1139 142 500 26.1 13.0 1759 1583 135 1000 28.1 28.1 3246 2922 116 BXRC-50C1001-B-8x-SE 70 100 32.9 3.3 667 601 203 150 33.6 5.0 975 877 194 200 34.2 6.8 1280 1152 187 270 35.0 9.5 1677 1509 177 400 36.5 14.6 2382 2144 163 500 37.5 18.7 2885 2597 154 BXRC-50C1001-C-8x-SE 70 150 29.8 4.5 904 814 202 225 30.3 6.8 1320 1188 194 300 30.7 9.2 1726 1554 187 360 31.1 11.2 2046 1841 183 600 32.4 19.4 3268 2941 168 1000 34.3 34.3 5111 4600 149 BXRC-50C1001-D-8x-SE 70 125 24.3 3.0 612 550 202 185 24.6 4.5 880 792 194 250 24.9 6.2 1166 1049 187 350 25.4 8.9 1595 1436 180 500 26.1 13.0 2217 1995 170 1000 28.1 28.1 4091 3682 146 BXRC-50E1001-B-8x-SE 80 100 32.9 3.3 642 578 195 150 33.6 5.0 938 844 186 200 34.2 6.8 1232 1108 180 270 35.0 9.5 1613 1452 171 400 36.5 14.6 2292 2062 157 500 37.5 18.7 2775 2498 148 BXRC-50E1001-C-8x-SE 80 150 29.8 4.5 870 783 194 225 30.3 6.8 1269 1143 186 300 30.7 9.2 1661 1495 180 360 31.1 11.2 1968 1771 176 600 32.4 19.4 3144 2829 162 1000 34.3 34.3 4916 4425 143 BXRC-50E1001-D-8x-SE 80 125 24.3 3.0 588 530 194 185 24.6 4.5 846 762 186 250 24.9 6.2 1121 1009 180 350 25.4 8.9 1535 1381 173 500 26.1 13.0 2132 1919 164 1000 28.1 28.1 3935 3542 140 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-50G1001-B-8x-SE 90 100 32.9 3.3 555 499 169 150 33.6 5.0 810 729 161 200 34.2 6.8 1065 958 156 270 35.0 9.5 1394 1255 147 400 36.5 14.6 1981 1783 136 500 37.5 18.7 2399 2159 128 BXRC-50G1001-C-8x-SE 90 150 29.8 4.5 752 677 168 225 30.3 6.8 1097 988 161 300 30.7 9.2 1436 1292 156 360 31.1 11.2 1701 1531 152 600 32.4 19.4 2717 2446 140 1000 34.3 34.3 4250 3825 124 BXRC-50G1001-D-8x-SE 90 125 24.3 3.0 509 458 168 185 24.6 4.5 732 659 161 250 24.9 6.2 969 872 156 350 25.4 8.9 1326 1194 149 500 26.1 13.0 1843 1659 141 1000 28.1 28.1 3402 3062 121 BXRC-57C1001-B-8x-SE 70 100 32.9 3.3 649 584 197 150 33.6 5.0 948 853 188 200 34.2 6.8 1246 1121 182 270 35.0 9.5 1631 1468 172 400 36.5 14.6 2317 2086 159 500 37.5 18.7 2807 2526 150 BXRC-57C1001-C-8x-SE 70 150 29.8 4.5 880 792 197 225 30.3 6.8 1284 1155 188 300 30.7 9.2 1679 1512 182 360 31.1 11.2 1990 1791 178 600 32.4 19.4 3179 2861 164 1000 34.3 34.3 4972 4475 145 BXRC-57C1001-D-8x-SE 70 125 24.3 3.0 595 536 196 185 24.6 4.5 856 770 188 250 24.9 6.2 1134 1021 182 350 25.4 8.9 1552 1397 175 500 26.1 13.0 2157 1941 165 1000 28.1 28.1 3980 3582 142 BXRC-57E1001-B-8x-SE 80 100 32.9 3.3 617 555 187 150 33.6 5.0 900 810 179 200 34.2 6.8 1183 1065 173 270 35.0 9.5 1549 1394 164 400 36.5 14.6 2201 1981 151 500 37.5 18.7 2666 2399 142 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-57E1001-C-8x-SE 80 150 29.8 4.5 836 752 187 225 30.3 6.8 1219 1097 179 300 30.7 9.2 1595 1436 173 360 31.1 11.2 1890 1701 169 600 32.4 19.4 3019 2717 155 1000 34.3 34.3 4722 4250 137 BXRC-57E1001-D-8x-SE 80 125 24.3 3.0 565 509 186 185 24.6 4.5 813 732 179 250 24.9 6.2 1077 969 173 350 25.4 8.9 1474 1326 166 500 26.1 13.0 2048 1843 157 1000 28.1 28.1 3780 3402 135 BXRC-65C1001-B-8x-SE 70 100 32.9 3.3 649 584 197 150 33.6 5.0 948 853 188 200 34.2 6.8 1246 1121 182 270 35.0 9.5 1631 1468 172 400 36.5 14.6 2317 2086 159 500 37.5 18.7 2807 2526 150 BXRC-65C1001-C-8x-SE 70 150 29.8 4.5 880 792 197 225 30.3 6.8 1284 1155 188 300 30.7 9.2 1679 1512 182 360 31.1 11.2 1990 1791 178 600 32.4 19.4 3179 2861 164 1000 34.3 34.3 4972 4475 145 BXRC-65C1001-D-8x-SE 70 125 24.3 3.0 595 536 196 185 24.6 4.5 856 770 188 250 24.9 6.2 1134 1021 182 350 25.4 8.9 1552 1397 175 500 26.1 13.0 2157 1941 165 1000 28.1 28.1 3980 3582 142 BXRC-65E1001-B-8x-SE 80 100 32.9 3.3 624 561 190 150 33.6 5.0 911 820 181 200 34.2 6.8 1197 1077 175 270 35.0 9.5 1568 1411 166 400 36.5 14.6 2227 2004 153 500 37.5 18.7 2697 2427 144 BXRC-65E1001-C-8x-SE 80 150 29.8 4.5 845 761 189 225 30.3 6.8 1234 1110 181 300 30.7 9.2 1614 1452 175 360 31.1 11.2 1912 1721 171 600 32.4 19.4 3055 2749 157 1000 34.3 34.3 4777 4300 139 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-65E1001-D-8x-SE 80 125 24.3 3.0 572 515 188 185 24.6 4.5 823 740 181 250 24.9 6.2 1090 981 175 350 25.4 8.9 1491 1342 168 500 26.1 13.0 2072 1865 159 1000 28.1 28.1 3824 3442 136 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Electrical Characteristics

Table 5: Electrical Characteristics Part Number Drive Current (mA) Forward Voltage Pulsed, Tc = 25ºC (V) 1, 2, 3, 8 Typical Coefficient of Forward Voltage4 ∆Vf/∆Tc (mV/ºC) Typical Thermal Resistance Junction to Case5,6 Rj-c (ºC/W) Driver Selection Voltages7 (V) Minimum Typical Maximum Vf Min. Hot Tc = 105ºC (V) Vf Max. Cold Tc = -40ºC (V) BXRC-xxx100x-B-8x-SE BXRC-xxx100x-C-8x-SE BXRC-xxx100x-D-8x-SE Notes for Table 5: 1. Parts are tested in pulsed conditions, Tc = 25°C. Pulse width is 10ms. 2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance. 3. Bridgelux maintains a tester tolerance of ± 0.10V on forward voltage measurements. 4. Typical coefficient of forward voltage tolerance is ± 0.1mV for nominal current. 5. Thermal resistance values are based from test data of a 3000K 80 CRI product. 6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal interface material used during testing is not included in the thermal resistance value. 7. Vf min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design and selection over the operating range of the product. 8. This product has been designed and manufactured per IEC 62031:2018. This product has passed dielectric withstand voltage testing at 1140 V. The work- ing voltage designated for the insulation is 70V d.c. The maximum allowable voltage across the array must be determined in the end product application.

Table 6: Eye Safety Risk Group (RG) Classifications Part Number Drive Current (mA) CCT 2700K/3000K 4000K2 5000K3 6500K4 BXRC-xxx100x-B-8x-SE

355 RG1 RG1 RG1 RG1

500 RG1 RG1 RG1 RG2

395 RG1 RG1 RG1 RG1

550 RG1 RG1 RG1 RG2

730 RG1 RG1 RG2 RG2

1000 RG1 RG2 RG2 RG2

490 RG1 RG1 RG1 RG1

680 RG1 RG1 RG1 RG2

900 RG1 RG1 RG2 RG2

Notes for Table 6: 1. Eye safety classification for the use of Bridgelux Vero Series LED arrays is in accordance with specification IEC/TR 62778: Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires. 2. For products classified as RG2 at 4000K, Ethr= 1980 lx. 3. For products classified as RG2 at 5000K Ethr= 1530 lx. 4. For products classified as RG2 at 6500K, Ethr= 1170 lx. 5. Please contact your Bridgelux sales representative for Ethr values at specific drive currents and CCTs not listed.

LED Junction Temperature (Tj) 150°C Storage Temperature -40°C to +105°C Operating Case Temperature1 (Tc) 105°C Soldering Temperature2 300°C or lower for a maximum of 6 seconds BXRC-xxx100x-B-8x-SE BXRC-xxx100x-C-8x-SE BXRC-xxx100x-D-8x-SE Maximum Drive Current3 500 mA 1000 mA 1000 mA Maximum Peak Pulsed Drive Current4 560 mA 1120 mA 1120 mA Maximum Reverse Voltage5 -60V -55V -45V Notes for Table 7: 1. For IEC 62717 requirement, please consult your Bridgelux sales representative. 2. Refer to Bridgelux Application Note AN120: Bridgelux Vero SE Array Design Guide. 3. Arrays may be driven at higher currents however lumen maintenance may be reduced and warranty will not apply. 4. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed current specified. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures. 5. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating provided for reference only. Table 7: Maximum Ratings

Figure 12: Typical Color Spectrum Notes for Figure 12: 1. Color spectra measured at nominal current for Tj = Tc = 25°C. 2. Color spectra shown is 3000K and 80 CRI. 3. Color spectra shown is 4000K and 80 CRI. 4. Color spectra shown is 5000K and 70 CRI. 4. Color spectra shown is 6500K and 70 CRI. 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 110% 400 450 500 550 600 650 700 750 800 Relative Spectral Power Distribution Wavelength (nm) 3000K 4000K 5000K 6500K

Figure 13: Drawing for Vero SE 10 LED Array Notes for Figure 13: 1. Drawings are not to scale. 2. Drawing dimensions are in millimeters. 3. Unless otherwise specified, tolerances are ±0.15mm. 4. Mounting holes (2X) are for M3 screws. 5. Bridgelux recommends two tapped holes for mounting screws with 18.9 ± 0.10mm center-to-center spacing. 6. Screws with flat shoulders (pan, dome, button, round, truss, mushroom) provide optimal torque control. Do NOT use flat, countersink, or raised head screws. 7. The optical center of the LED Array is nominally defined by the mechanical center of the array to a tolerance of ± 0.2mm. 8. Bridgelux maintains a flatness of 0.10mm across the mounting surface of the array

Figure 14: Warm and Neutral White Test Bins in xy Color Space Color Binning Information Bin Code 2700K 3000K 3500K 4000K ANSI Bin (for reference only) (2580K - 2870K) (2870K - 3220K) (3220K - 3710K) (3710K - 4260K) 83 (3 SDCM) (2651K - 2794K) (2968K - 3136K) (3369K - 3586K) (3851K - 4130K) 82 (2 SDCM) (2674K - 2769K) (2995K - 3107K) (3404K - 3548K) (3895K - 4081K) Table 8: Warm and Neutral White xy Bin Coordinates and Associated Typical CCT Bin Code 5000K 5700K 6500K ANSI Bin (for reference only) (4745K - 5311K) (5312K - 6022K) (6022K - 7042K) 84 (4 SDCM) (4801K - 5282K) (5395K- 5970K) (6200K - 6910K) 83 (3 SDCM) (4835K-5215K) (5460K- 5891K) (6279K -6811K) Table 9: Cool White xy Bin Coordinates and Associated Typical CCT (product is hot targeted to Tc = 85°C) Note: Pulsed Test Conditions, Tc = 25°C Figure 15: Graph of Cool White Test Bins in xy Color Space Note: Pulsed Test Conditions, Tc = 25°C 0.3 0.31 0.32 0.33 0.34 0.35 0.36 0.37 0.38 0.39 Y X

4 SDCM

3 SDCM

Note for Tables 8-9: 1. Bridgelux maintains a tolerance of +/- 0.007 on x and y color coordinates in the CIE 1931 color Space.

Figure 16: Drawing for Vero SE 10 Packaging Tray Notes for Figure 16: 1. Dimensions are in millimeters. 2. Drawings are not to scale.

Bridgelux has developed a comprehensive set of application notes and design resources to assist customers in successfully designing with the Vero product family of LED array products. For all available application notes visit www.bridgelux.com. Optical Source Models Optical source models and ray set files are available for all Bridgelux products. For a list of available formats, visit www.bridgelux.com. MINOR PRODUCT CHANGE POLICY The rigorous qualification testing on products offered by Bridgelux provides performance assurance. Slight cos- metic changes that do not affect form, fit, or function may occur as Bridgelux continues product optimization. CAUTION: CHEMICAL EXPOSURE HAZARD Exposure to some chemicals commonly used in luminaire manufacturing and assembly can cause damage to the LED array. Please consult Bridgelux CAUTION: RISK OF BURN Do not touch the Vero LED array during operation. Allow the array to cool for a sufficient period of time before handling. The Vero LED array may reach elevated temperatures such that could burn skin when touched. 3D CAD Models Three dimensional CAD models depicting the product outline of all Bridgelux Vero LED arrays are available in both IGS and STEP formats. Please contact your Bridgelux sales representative for assistance. LM80 LM80 testing has been completed and the LM80 report is now available. Please contact your Bridgelux sales representative for LM-80 report. CAUTION CONTACT WITH LIGHT EMITTING SURFACE (LES) Avoid any contact with the LES. Do not touch the LES of the LED array or apply stress to the LES (yellow phosphor resin area). Contact may cause damage to the LED array. Optics and reflectors must not be mounted in contact with the LES (yellow phosphor resin area). Optical devices may be mounted on the top surface of the plas- tic housing of the Vero LED array. Use the mechanical features of the LED array housing, edges and/or mounting holes to locate and secure optical devices as needed. STANDARD TEST CONDITIONS Unless otherwise stated, array testing is performed at the nominal drive current.

About Bridgelux: Bridging Light and Life™ © 2023 Bridgelux, Inc. All rights reserved. Product specifications are subject to change without notice. Bridgelux, the Bridgelux stylized logo design, Vero, V Series and V Series HD are registered trademarks, and Decor Series is a trademark of Bridgelux, Inc. All other trademarks are the property of their respective owners. Bridgelux Gen 8 Vero SE 10 Array Series Product Data Sheet DS430 Rev. E (07/2023)

46410 Fremont Boulevard

Fremont, CA 94538 U.S.A. Tel (925) 583-8400 www.bridgelux.com At Bridgelux, we help companies, industries and people experience the power and possibility of light. Since 2002, we’ve designed LED solutions that are high performing, energy efficient, cost effective and easy to integrate. Our focus is on light’s impact on human behavior, delivering products that create better environments, experiences and returns—both experiential and financial. And our patented technology drives new platforms for commercial and industrial luminaires. For more information about the company, please visit bridgelux.com twitter.com/Bridgelux facebook.com/Bridgelux youtube.com/user/Bridgelux linkedin.com/company/bridgelux-inc-_2 WeChat ID: BridgeluxInChina