Datasheet sections

29 Array

The Vero® Series is a revolutionary advancement in chip on board (COB) light source technology and innovation, simplifying the luminaire design and manufacturing processes. Vero Chip on Board (COB) LED arrays are available in four LES configurations, engineered to enable new degrees of flexibility and reliability over a broad range of electrical currents. Vero arrays deliver increased lumen density to enable improved beam control and precision lighting with 2 and 3 SDCM color control standard for clean and consistent uniform lighting. Vero products include an onboard connector port that enables a solder-free electrical interconnect, and simple mounting features for plug-and-play installation. Vero® Series

Features

  • On board connector port
  • Top side part number markings
  • Efficacy of 185 lm/W typical, 3000K 80 CRI
  • Reliable operation at up to 3x nominal current, 30% increase in maximum lumens per LES size
  • Wide selection of CCT options (2700K-6500K) with minimum 70, 80 and 90 CRI options
  • Uniform high-quality illumination
  • 2 and 3 SDCM binning options (2700K – 4000K)
  • Forward voltage bin codes (backside marking)
  • Thermally isolated solder pads
  • 10-Year warranty Benefits
  • Solder free installation and field upgradability
  • Improved inventory management and quality control
  • Enables high efficiency lighting systems and lower operating costs
  • Supports the trend toward luminaire miniaturization and delivers enhanced optical control
  • Design flexibility for a broad range of lighting

applications

  • Clean white light without pixelation
  • Uniform consistent white light
  • Design flexibility for multi-source applications
  • Enhanced ease of use and installation
  • Design with confidence

The part number designation for Bridgelux Vero LED arrays is explained as follows: 1 2 3 4 5 6 7 8 9 10 11 – 12 – 13 14 Product Family CCT Bin Options 2 = 2 SDCM 3 = 3 SDCM 4 = 4 SDCM CRI. C = 70 CRI min. E = 80 CRI min. G = 90 CRI min. H = 97 CRI typ. Array Configuration 27 = 2,700K 30 = 3,000K 35 = 3,500K 40 = 4,000K 50 = 5,000K 56 = 5,600K 57 = 5,700K 65 = 6,500K BXRC – 30 E 10K 0 – C – 8 3 Color Targeting Designator 0 = Cold Targeted 1 = Hot Targeted Gen. 8Nominal CCT Flux Indicator 10Kx = 10,000 lm Vero 29 is the largest form factor in the Vero family of next generation solid state light sources. In addition to delivering the performance and light quality required for many lighting applications, Vero incorporates several features to simplify the design integration and manufacturing process, accelerate time to market and reduce system costs. Please visit www.bridgelux.com for more information on the Vero Series family of products. Mounting holes Polarity indication marks simplify manufacturing operator instructions 2D Bar code provides full manufacturing traceability Solderless connector port enables simplified manufacturing processes, reduced inventory carrying costs and can enable field upgradability Thermally isolated solder pads reduce manufacturing cycle time and complexity Tc Measurement point Top side part number marking improves inventory management and outgoing quality control Radial die configuration improves lumen density and beam control Optional Bridgelux Vero wire harness (sold separately)

The following product configurations are available: Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-27E10K0-B-8x 2700 80 1400 12247 11022 50.2 70.3 174 BXRC-27E10K0-C-8x 2700 80 1300 15099 13589 66.7 86.7 174 BXRC-27E10K0-D-8x 2700 80 1700 10771 9694 36.4 61.9 174 BXRC-27G10K0-B-8x 2700 90 1400 10103 9093 50.2 70.3 144 BXRC-27G10K0-C-8x 2700 90 1300 12457 11211 66.7 86.7 144 BXRC-27G10K0-D-8x 2700 90 1700 8886 7997 36.4 61.9 144 BXRC-27G1KH0-B-8x 2700 90 1400 10540 9486 50.2 70.3 150 BXRC-27G1KH0-C-8x 2700 90 1300 12995 11695 66.7 86.7 150 BXRC-27G1KH0-D-8x 2700 90 1700 9270 8343 36.4 61.9 150 BXRC-27H10K0-B-8x 2700 97 1400 8955 8060 50.2 70.3 127 BXRC-27H10K0-C-8x 2700 97 1300 11041 9937 66.7 86.7 127 BXRC-27H10K0-D-8x 2700 97 1700 7876 7089 36.4 61.9 127 BXRC-30C10K1-B-8x 3000 70 1400 13624 12262 50.2 70.3 194 BXRC-30C10K1-C-8x 3000 70 1300 16798 15118 66.7 86.7 194 BXRC-30C10K1-D-8x 3000 70 1700 11983 10784 36.4 61.9 194 BXRC-30E10K0-B-8x 3000 80 1400 13012 11711 50.2 70.3 185 BXRC-30E10K0-C-8x 3000 80 1300 16043 14439 66.7 86.7 185 BXRC-30E10K0-D-8x 3000 80 1700 11444 10300 36.4 61.9 185 BXRC-30G10K0-B-8x 3000 90 1400 10563 9506 50.2 70.3 150 BXRC-30G10K0-C-8x 3000 90 1300 13023 11721 66.7 86.7 150 BXRC-30G10K0-D-8x 3000 90 1700 9290 8361 36.4 61.9 150 BXRC-30G1KH0-B-8x 3000 90 1400 11060 9954 50.2 70.3 157 BXRC-30G1KH0-C-8x 3000 90 1300 13637 12273 66.7 86.7 157 BXRC-30G1KH0-D-8x 3000 90 1700 9727 8755 36.4 61.9 157 BXRC-30H10K0-B-8x 3000 97 1400 9568 8611 50.2 70.3 136 BXRC-30H10K0-C-8x 3000 97 1300 11796 10617 66.7 86.7 136 BXRC-30H10K0-D-8x 3000 97 1700 8415 7573 36.4 61.9 136 BXRC-35E10K0-B-8x 3500 80 1400 13318 11986 50.2 70.3 190 BXRC-35E10K0-C-8x 3500 80 1300 16420 14778 66.7 86.7 189 BXRC-35E10K0-D-8x 3500 80 1700 11713 10542 36.4 61.9 189 BXRC-35G10K0-B-8x 3500 90 1400 10945 9851 50.2 70.3 156 BXRC-35G10K0-C-8x 3500 90 1300 13495 12145 66.7 86.7 156 BXRC-35G10K0-D-8x 3500 90 1700 9626 8664 36.4 61.9 156 BXRC-40C10K1-B-8x 4000 70 1400 14007 12606 50.2 70.3 199 BXRC-40C10K1-C-8x 4000 70 1300 17270 15543 66.7 86.7 199 BXRC-40C10K1-D-8x 4000 70 1700 12319 11087 36.4 61.9 199 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are minimums for all products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50. Minimum R9 value for 97 CRI products is 93 on 2700K and 3000K,and it is 85 on 3500K /4000K/5000K and 5700K. Bridgelux maintains a ± 3 tolerance on R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal drive current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test.

Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-40E10K0-B-8x 4000 80 1400 13395 12055 50.2 70.3 191 BXRC-40E10K0-C-8x 4000 80 1300 16515 14863 66.7 86.7 190 BXRC-40E10K0-D-8x 4000 80 1700 11781 10603 36.4 61.9 190 BXRC-40G10K0-B-8x 4000 90 1400 11175 10058 50.2 70.3 159 BXRC-40G10K0-C-8x 4000 90 1300 13778 12400 66.7 86.7 159 BXRC-40G10K0-D-8x 4000 90 1700 9828 8846 36.4 61.9 159 BXRC-50C10K1-B-8x 5000 70 1400 14084 12675 50.2 70.3 200 BXRC-50C10K1-C-8x 5000 70 1300 17364 15628 66.7 86.7 200 BXRC-50C10K1-D-8x 5000 70 1700 12386 11148 36.4 61.9 200 BXRC-50E10K1-B-8x 5000 80 1400 13548 12193 50.2 70.3 193 BXRC-50E10K1-C-8x 5000 80 1300 16704 15033 66.7 86.7 193 BXRC-50E10K1-D-8x 5000 80 1700 11915 10724 36.4 61.9 193 BXRC-50G10K1-B-8x 5000 90 1400 11711 10540 50.2 70.3 167 BXRC-50G10K1-C-8x 5000 90 1300 14439 12995 66.7 86.7 167 BXRC-50G10K1-D-8x 5000 90 1700 10300 9270 36.4 61.9 166 BXRC-56H10K0-C-8x 5600 97 1300 13118 11806 66.7 86.7 151 BXRC-56H10K0-D-8x 5600 97 1700 9357 8421 36.4 61.9 151 BXRC-57C10K1-B-8x 5700 70 1400 13701 12331 50.2 70.3 195 BXRC-57C10K1-C-8x 5700 70 1300 16892 15203 66.7 86.7 195 BXRC-57C10K1-D-8x 5700 70 1700 12050 10845 36.4 61.9 195 BXRC-57E10K1-B-8x 5700 80 1400 13012 11711 50.2 70.3 185 BXRC-57E10K1-C-8x 5700 80 1300 16043 14439 66.7 86.7 185 BXRC-57E10K1-D-8x 5700 80 1700 11444 10300 36.4 61.9 185 BXRC-65C10K1-B-8x 6500 70 1400 13701 12331 50.2 70.3 195 BXRC-65C10K1-C-8x 6500 70 1300 16892 15203 66.7 86.7 195 BXRC-65C10K1-D-8x 6500 70 1700 12050 10845 36.4 61.9 195 BXRC-65E10K1-B-8x 6500 80 1400 13165 11849 50.2 70.3 187 BXRC-65E10K1-C-8x 6500 80 1300 16232 14609 66.7 86.7 187 BXRC-65E10K1-D-8x 6500 80 1700 11579 10421 36.4 61.9 187 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are minimums for all products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50. Minimum R9 value for 97 CRI products is 93 on 2700K and 3000K,and it is 85 on 3500K /4000K/5000K and 5700K. Bridgelux maintains a ± 3 tolerance on R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal drive current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test.

Table 2: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-27E10K0-B-8x 2700 80 1400 11022 9920 49.2 68.9 160 BXRC-27E10K0-C-8x 2700 80 1300 13589 12230 65.4 85.0 160 BXRC-27E10K0-D-8x 2700 80 1700 9694 8724 35.7 60.7 160 BXRC-27G10K0-B-8x 2700 90 1400 9093 8184 49.2 68.9 132 BXRC-27G10K0-C-8x 2700 90 1300 11211 10090 65.4 85.0 132 BXRC-27G10K0-D-8x 2700 90 1700 7997 7198 35.7 60.7 132 BXRC-27G1KH0-B-8x 2700 90 1400 9486 8537 49.2 68.9 138 BXRC-27G1KH0-C-8x 2700 90 1300 11695 10526 65.4 85.0 138 BXRC-27G1KH0-D-8x 2700 90 1700 8343 7508 35.7 60.7 138 BXRC-27H10K0-B-8x 2700 97 1400 8060 7254 49.2 68.9 117 BXRC-27H10K0-C-8x 2700 97 1300 9937 8944 65.4 85.0 117 BXRC-27H10K0-D-8x 2700 97 1700 7089 6380 35.7 60.7 117 BXRC-30C10K1-B-8x 3000 70 1400 12262 11036 49.2 68.9 178 BXRC-30C10K1-C-8x 3000 70 1300 15118 13606 65.4 85.0 178 BXRC-30C10K1-D-8x 3000 70 1700 10784 9706 35.7 60.7 178 BXRC-30E10K0-B-8x 3000 80 1400 11711 10540 49.2 68.9 170 BXRC-30E10K0-C-8x 3000 80 1300 14439 12995 65.4 85.0 170 BXRC-30E10K0-D-8x 3000 80 1700 10300 9270 35.7 60.7 170 BXRC-30G10K0-B-8x 3000 90 1400 9506 8556 49.2 68.9 138 BXRC-30G10K0-C-8x 3000 90 1300 11721 10549 65.4 85.0 138 BXRC-30G10K0-D-8x 3000 90 1700 8361 7525 35.7 60.7 138 BXRC-30G1KH0-B-8x 3000 90 1400 9954 8959 49.2 68.9 144 BXRC-30G1KH0-C-8x 3000 90 1300 12273 11046 65.4 85.0 144 BXRC-30G1KH0-D-8x 3000 90 1700 8755 7879 35.7 60.7 144 BXRC-30H10K0-B-8x 3000 97 1400 8611 7750 49.2 68.9 125 BXRC-30H10K0-C-8x 3000 97 1300 10617 9555 65.4 85.0 125 BXRC-30H10K0-D-8x 3000 97 1700 7573 6816 35.7 60.7 125 BXRC-35E10K0-B-8x 3500 80 1400 11986 10788 49.2 68.9 174 BXRC-35E10K0-C-8x 3500 80 1300 14778 13301 65.4 85.0 174 BXRC-35E10K0-D-8x 3500 80 1700 10542 9488 35.7 60.7 174 BXRC-35G10K0-B-8x 3500 90 1400 9851 8866 49.2 68.9 143 BXRC-35G10K0-C-8x 3500 90 1300 12145 10931 65.4 85.0 143 BXRC-35G10K0-D-8x 3500 90 1700 8664 7797 35.7 60.7 143 BXRC-40C10K1-B-8x 4000 70 1400 12606 11346 49.2 68.9 183 BXRC-40C10K1-C-8x 4000 70 1300 15543 13989 65.4 85.0 183 BXRC-40C10K1-D-8x 4000 70 1700 11087 9978 35.7 60.7 183 Notes for Table 2: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are minimums for all products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50. Minimum R9 value for 97 CRI products is 93 on 2700K and 3000K,and it is 85 on 3500K /4000K/5000K and 5700K. Bridgelux maintains a ± 3 tolerance on R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.

Table 2: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-40E10K0-B-8x 4000 80 1400 12055 10850 49.2 68.9 175 BXRC-40E10K0-C-8x 4000 80 1300 14863 13377 65.4 85.0 175 BXRC-40E10K0-D-8x 4000 80 1700 10603 9542 35.7 60.7 175 BXRC-40G10K0-B-8x 4000 90 1400 10058 9052 49.2 68.9 146 BXRC-40G10K0-C-8x 4000 90 1300 12400 11160 65.4 85.0 146 BXRC-40G10K0-D-8x 4000 90 1700 8846 7961 35.7 60.7 146 BXRC-50C10K1-B-8x 5000 70 1400 12675 11408 49.2 68.9 184 BXRC-50C10K1-C-8x 5000 70 1300 15628 14065 65.4 85.0 184 BXRC-50C10K1-D-8x 5000 70 1700 11148 10033 35.7 60.7 184 BXRC-50E10K1-B-8x 5000 80 1400 12193 10974 49.2 68.9 177 BXRC-50E10K1-C-8x 5000 80 1300 15033 13530 65.4 85.0 177 BXRC-50E10K1-D-8x 5000 80 1700 10724 9651 35.7 60.7 177 BXRC-50G10K1-B-8x 5000 90 1400 10540 9486 49.2 68.9 153 BXRC-50G10K1-C-8x 5000 90 1300 12995 11695 65.4 85.0 153 BXRC-50G10K1-D-8x 5000 90 1700 9270 8343 35.7 60.7 153 BXRC-56H10K0-C-8x 5600 97 1300 11806 10626 65.4 85.0 139 BXRC-56H10K0-D-8x 5600 97 1700 8422 7579 35.7 60.7 139 BXRC-57C10K1-B-8x 5700 70 1400 12331 11098 49.2 68.9 179 BXRC-57C10K1-C-8x 5700 70 1300 15203 13683 65.4 85.0 179 BXRC-57C10K1-D-8x 5700 70 1700 10845 9760 35.7 60.7 179 BXRC-57E10K1-B-8x 5700 80 1400 11711 10540 49.2 68.9 170 BXRC-57E10K1-C-8x 5700 80 1300 14439 12995 65.4 85.0 170 BXRC-57E10K1-D-8x 5700 80 1700 10300 9270 35.7 60.7 170 BXRC-65C10K1-B-8x 6500 70 1400 12331 11098 49.2 68.9 179 BXRC-65C10K1-C-8x 6500 70 1300 15203 13683 65.4 85.0 179 BXRC-65C10K1-D-8x 6500 70 1700 10845 9760 35.7 60.7 179 BXRC-65E10K1-B-8x 6500 80 1400 11849 10664 49.2 68.9 172 BXRC-65E10K1-C-8x 6500 80 1300 14609 13148 65.4 85.0 172 BXRC-65E10K1-D-8x 6500 80 1700 10421 9379 35.7 60.7 172 Notes for Table 2: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are minimums for all products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50. Minimum R9 value for 97 CRI products is 93 on 2700K and 3000K,and it is 85 on 3500K /4000K/5000K and 5700K. Bridgelux maintains a ± 3 tolerance on R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.

European Product Registry for Energy Labeling The European Product Registry for Energy Labeling (EPREL) is defined in the EU Regulation 2017/1369 to provide import- ant energy efficiency information to consumers. Together with Energy Labeling Regulation ELR (EU) 2019/2015 which was amended by regulation (EU) 2021/340 for energy labelling of light sources, manufacturers are required to declare an ener- gy class based on key technical specifications from each of their product and register it in an open data base managed by EPREL It is now a legal requirement for a vendor of light sources to upload information about their products into the EPREL database before placing these products on the market in the EU. Table 3 below provides a list of part numbers that are in compliance with ELR and are currently listed in the EPREL data- base. At Bridgelux, we are fully committed to supplying products that are compliant with pertinent laws, rules, and obligation imposed by relevant government bodies including the European Energy Labeling regulation. Customers can use these products with full confidence for any projects that fall under the ELR. Table 3: Part numbers registered in European Product Registry for Energy Labeling PART NUMBER1 CCT (K) CRI Current2 (mA) Vf (V) Useful flux3 (Φuse) at 85C (lm) Pow- er (W) Efficacy (lm/W) Energy efficiency class4 Regis- tration No URL to Product Information Sheet in EPREL Database Notes for Table 3: 1. All device listed here must be disposed as e-waste upon its end of life according to local country guideline in each country. 2. For information on performance values at alternative drive conditions. please refer to the Product Selection Guide, Absolute Maximum Rating Table and Performance Curves in this data sheet. 3. For a definition of useful luminous flux (ΦΦuse), please see the ELR regulations at https:/ /tinyurl.com/4b6zvt4m. 4. EPREL requires an arrow symbol containing the letter of the energy efficiency class to be displayed. on technical promotional material. Refer to this energy efficiency class column for specific energy efficiency class on each part number.

European Product Registry for Energy Labeling Table 3: Part numbers registered in European Product Registry for Energy Labeling (Continued) PART NUMBER1 CCT (K) CRI Current2 (mA) Vf (V) Useful flux3 (Φuse) at 85C (lm) Pow- er (W) Efficacy (lm/W) Energy efficiency class4 Regis- tration No URL to Product Information Sheet in EPREL Database Notes for Table 3: 1. All device listed here must be disposed as e-waste upon its end of life according to local country guideline in each country. 2. For information on performance values at alternative drive conditions. please refer to the Product Selection Guide, Absolute Maximum Rating Table and Performance Curves in this data sheet. 3. For a definition of useful luminous flux (ΦΦuse), please see the ELR regulations at https:/ /tinyurl.com/4b6zvt4m. 4. EPREL requires an arrow symbol containing the letter of the energy efficiency class to be displayed. on technical promotional material. Refer to this energy efficiency class column for specific energy efficiency class on each part number.

European Product Registry for Energy Labeling Table 3: Part numbers registered in European Product Registry for Energy Labeling (Continued) PART NUMBER1 CCT (K) CRI Current2 (mA) Vf (V) Useful flux3 (Φuse) at 85C (lm) Pow- er (W) Efficacy (lm/W) Energy efficiency class4 Regis- tration No URL to Product Information Sheet in EPREL Database Notes for Table 3: 1. All device listed here must be disposed as e-waste upon its end of life according to local country guideline in each country. 2. For information on performance values at alternative drive conditions. please refer to the Product Selection Guide, Absolute Maximum Rating Table and Performance Curves in this data sheet. 3. For a definition of useful luminous flux (ΦΦuse), please see the ELR regulations at https:/ /tinyurl.com/4b6zvt4m. 4. EPREL requires an arrow symbol containing the letter of the energy efficiency class to be displayed. on technical promotional material. Refer to this energy efficiency class column for specific energy efficiency class on each part number.

Performance at Commonly Used Drive Currents Vero LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. Vero may also be driven at other drive currents dependent on specific application design requirements. The performance at any drive current can be derived from the current vs. voltage characteristics shown in Figures 1, 2 & 3 and the flux vs. current characteristics shown in Figures 4, 5 & 6. The performance at commonly used drive currents is summarized in Table 4. Table 4: Product Performance at Commonly Used Drive Currents Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-27E10K0-B-8x 80 700 48.5 34.0 6175 5558 182 1050 49.4 51.9 9223 8301 178 1400 50.2 70.3 12247 11022 174 1800 51.2 92.1 15496 13946 168 2800 53.3 149.1 23309 20978 156 4750 56.6 268.8 36738 33064 137 BXRC-27E10K0-C-8x 80 650 64.4 41.9 7614 6852 182 975 65.6 64.0 11372 10235 178 1300 66.7 86.7 15099 13589 174 1710 68.0 116.4 19521 17569 168 2600 70.7 183.9 28739 25865 156 4750 75.8 360.1 48070 43263 134 BXRC-27E10K0-D-8x 80 850 35.1 29.9 5431 4888 182 1275 35.8 45.6 8112 7301 178 1700 36.4 61.9 10771 9694 174 2100 36.9 77.6 13122 11810 169 3400 38.6 131.1 20500 18450 156 5500 40.7 224.1 31080 27972 139 BXRC-27G10K0-B-8x 90 700 48.5 34.0 5095 4585 150 1050 49.4 51.9 7609 6848 147 1400 50.2 70.3 10103 9093 144 1800 51.2 92.1 12784 11506 139 2800 53.3 149.1 19230 17307 129 4750 56.6 268.8 30308 27278 113 BXRC-27G10K0-C-8x 90 650 64.4 41.9 6281 5653 150 975 65.6 64.0 9382 8444 147 1300 66.7 86.7 12457 11211 144 1710 68.0 116.4 16105 14494 138 2600 70.7 183.9 23709 21338 129 4750 75.8 360.1 39658 35692 110 BXRC-27G10K0-D-8x 90 850 35.1 29.9 4481 4033 150 1275 35.8 45.6 6692 6023 147 1700 36.4 61.9 8886 7997 144 2100 36.9 77.6 10826 9743 140 3400 38.6 131.1 16913 15221 129 5500 40.7 224.1 25641 23077 114 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-27G1KH0-B-8x 90 700 48.5 34.0 5315 4783 156 1050 49.4 51.9 7938 7144 153 1400 50.2 70.3 10540 9486 150 1800 51.2 92.1 13336 12002 145 2800 53.3 149.1 20060 18054 135 4750 56.6 268.8 31617 28456 118 BXRC-27G1KH0-C-8x 90 650 64.4 41.9 6553 5897 156 975 65.6 64.0 9787 8808 153 1300 66.7 86.7 12995 11695 150 1710 68.0 116.4 16800 15120 144 2600 70.7 183.9 24733 22260 135 4750 75.8 360.1 41370 37233 115 BXRC-27G1KH0-D-8x 90 850 35.1 29.9 4674 4207 156 1275 35.8 45.6 6981 6283 153 1700 36.4 61.9 9270 8343 150 2100 36.9 77.6 11294 10164 146 3400 38.6 131.1 17643 15879 135 5500 40.7 224.1 26748 24073 119 BXRC-27H10K0-B-8x 97 typ. 700 48.5 34.0 4516 4064 133 1050 49.4 51.9 6745 6070 130 1400 50.2 70.3 8955 8060 127 1800 51.2 92.1 11331 10198 123 2800 53.3 149.1 17045 15340 114 4750 56.6 268.8 26864 24178 100 BXRC-27H10K0-C-8x 97 typ. 650 64.4 41.9 5568 5011 133 975 65.6 64.0 8316 7484 130 1300 66.7 86.7 11041 9937 127 1710 68.0 116.4 14275 12847 123 2600 70.7 183.9 21015 18914 114 4750 75.8 360.1 35151 31636 98 BXRC-27H10K0-D-8x 97 typ. 850 35.1 29.9 3972 3574 133 1275 35.8 45.6 5932 5339 130 1700 36.4 61.9 7876 7089 127 2100 36.9 77.6 9596 8636 124 3400 38.6 131.1 14991 13492 114 5500 40.7 224.1 22727 20454 101 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Table 4: Product Performance at Commonly Used Drive Currents (Continued) Performance at Commonly Used Drive Currents Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-30C10K1-B-8x 70 700 48.5 34.0 6870 6183 202 1050 49.4 51.9 10261 9235 198 1400 50.2 70.3 13624 12262 194 1800 51.2 92.1 17239 15515 187 2800 53.3 149.1 25931 23338 174 4750 56.6 268.8 40871 36783 152 BXRC-30C10K1-C-8x 70 650 64.4 41.9 8470 7623 202 975 65.6 64.0 12651 11386 198 1300 66.7 86.7 16798 15118 194 1710 68.0 116.4 21717 19545 187 2600 70.7 183.9 31972 28775 174 4750 75.8 360.1 53478 48130 149 BXRC-30C10K1-D-8x 70 850 35.1 29.9 6042 5438 202 1275 35.8 45.6 9025 8122 198 1700 36.4 61.9 11983 10784 194 2100 36.9 77.6 14599 13139 188 3400 38.6 131.1 22806 20526 174 5500 40.7 224.1 34576 31119 154 BXRC-30E10K0-B-8x 80 700 48.5 34.0 6561 5905 193 1050 49.4 51.9 9800 8820 189 1400 50.2 70.3 13012 11711 185 1800 51.2 92.1 16464 14818 179 2800 53.3 149.1 24766 22289 166 4750 56.6 268.8 39034 35130 145 BXRC-30E10K0-C-8x 80 650 64.4 41.9 8090 7281 193 975 65.6 64.0 12083 10874 189 1300 66.7 86.7 16043 14439 185 1710 68.0 116.4 20741 18667 178 2600 70.7 183.9 30535 27481 166 4750 75.8 360.1 51074 45967 142 BXRC-30E10K0-D-8x 80 850 35.1 29.9 5771 5194 193 1275 35.8 45.6 8619 7757 189 1700 36.4 61.9 11444 10300 185 2100 36.9 77.6 13943 12548 180 3400 38.6 131.1 21781 19603 166 5500 40.7 224.1 33022 29720 147 BXRC-30G10K0-B-8x 90 700 48.5 34.0 5326 4794 157 1050 49.4 51.9 7955 7160 153 1400 50.2 70.3 10563 9506 150 1800 51.2 92.1 13365 12029 145 2800 53.3 149.1 20104 18094 135 4750 56.6 268.8 31686 28518 118 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-30G10K0-C-8x 90 650 64.4 41.9 6567 5910 157 975 65.6 64.0 9808 8827 153 1300 66.7 86.7 13023 11721 150 1710 68.0 116.4 16837 15153 145 2600 70.7 183.9 24787 22308 135 4750 75.8 360.1 41460 37314 115 BXRC-30G10K0-D-8x 90 850 35.1 29.9 4684 4216 157 1275 35.8 45.6 6997 6297 153 1700 36.4 61.9 9290 8361 150 2100 36.9 77.6 11318 10186 146 3400 38.6 131.1 17681 15913 135 5500 40.7 224.1 26806 24126 120 BXRC-30G1KH0-B-8x 90 700 48.5 34.0 5577 5019 164 1050 49.4 51.9 8330 7497 161 1400 50.2 70.3 11060 9954 157 1800 51.2 92.1 13995 12595 152 2800 53.3 149.1 21051 18946 141 4750 56.6 268.8 33179 29861 123 BXRC-30G1KH0-C-8x 90 650 64.4 41.9 6876 6189 164 975 65.6 64.0 10270 9243 161 1300 66.7 86.7 13637 12273 157 1710 68.0 116.4 17630 15867 152 2600 70.7 183.9 25955 23359 141 4750 75.8 360.1 43413 39072 121 BXRC-30G1KH0-D-8x 90 850 35.1 29.9 4905 4415 164 1275 35.8 45.6 7326 6594 161 1700 36.4 61.9 9727 8755 157 2100 36.9 77.6 11851 10666 153 3400 38.6 131.1 18514 16663 141 5500 40.7 224.1 28069 25262 125 BXRC-30H10K0-B-8x 97 typ. 700 48.5 34.0 4825 4342 142 1050 49.4 51.9 7206 6485 139 1400 50.2 70.3 9568 8611 136 1800 51.2 92.1 12106 10895 131 2800 53.3 149.1 18210 16389 122 4750 56.6 268.8 28701 25831 107 BXRC-30H10K0-C-8x 97 typ. 650 64.4 41.9 5948 5354 142 975 65.6 64.0 8884 7996 139 1300 66.7 86.7 11796 10617 136 1710 68.0 116.4 15251 13726 131 2600 70.7 183.9 22452 20207 122 4750 75.8 360.1 37554 33799 104 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-30H10K0-D-8x 97 typ. 850 35.1 29.9 4243 3819 142 1275 35.8 45.6 6337 5704 139 1700 36.4 61.9 8415 7573 136 2100 36.9 77.6 10252 9227 132 3400 38.6 131.1 16016 14414 122 5500 40.7 224.1 24281 21853 108 BXRC-35E10K0-B-8x 80 700 48.5 34.0 6716 6044 198 1050 49.4 51.9 10030 9027 193 1400 50.2 70.3 13318 11986 189 1800 51.2 92.1 16852 15166 183 2800 53.3 149.1 25349 22814 170 4750 56.6 268.8 39952 35957 149 BXRC-35E10K0-C-8x 80 650 64.4 41.9 8280 7452 198 975 65.6 64.0 12367 11130 193 1300 66.7 86.7 16420 14778 189 1710 68.0 116.4 21229 19106 182 2600 70.7 183.9 31253 28128 170 4750 75.8 360.1 52276 47048 145 BXRC-35E10K0-D-8x 80 850 35.1 29.9 5906 5316 198 1275 35.8 45.6 8822 7940 193 1700 36.4 61.9 11713 10542 189 2100 36.9 77.6 14271 12844 184 3400 38.6 131.1 22294 20065 170 5500 40.7 224.1 33799 30419 151 BXRC-35G10K0-B-8x 90 700 48.5 34.0 5519 4967 162 1050 49.4 51.9 8243 7419 159 1400 50.2 70.3 10945 9851 156 1800 51.2 92.1 13849 12464 150 2800 53.3 149.1 20832 18749 140 4750 56.6 268.8 32834 29551 122 BXRC-35G10K0-C-8x 90 650 64.4 41.9 6805 6124 162 975 65.6 64.0 10164 9147 159 1300 66.7 86.7 13495 12145 156 1710 68.0 116.4 17447 15702 150 2600 70.7 183.9 25685 23117 140 4750 75.8 360.1 42962 38666 119 BXRC-35G10K0-D-8x 90 850 35.1 29.9 4854 4369 162 1275 35.8 45.6 7250 6525 159 1700 36.4 61.9 9626 8664 156 2100 36.9 77.6 11728 10555 151 3400 38.6 131.1 18322 16490 140 5500 40.7 224.1 27778 25000 124 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-40C10K1-B-8x 70 700 48.5 34.0 7063 6357 208 1050 49.4 51.9 10549 9494 203 1400 50.2 70.3 14007 12606 199 1800 51.2 92.1 17723 15951 192 2800 53.3 149.1 26660 23994 179 4750 56.6 268.8 42019 37817 156 BXRC-40C10K1-C-8x 70 650 64.4 41.9 8708 7838 208 975 65.6 64.0 13007 11706 203 1300 66.7 86.7 17270 15543 199 1710 68.0 116.4 22327 20094 192 2600 70.7 183.9 32870 29583 179 4750 75.8 360.1 54980 49482 153 BXRC-40C10K1-D-8x 70 850 35.1 29.9 6212 5591 208 1275 35.8 45.6 9278 8350 203 1700 36.4 61.9 12319 11087 199 2100 36.9 77.6 15009 13508 193 3400 38.6 131.1 23447 21102 179 5500 40.7 224.1 35548 31993 159 BXRC-40E10K0-B-8x 80 700 48.5 34.0 6754 6079 199 1050 49.4 51.9 10088 9079 194 1400 50.2 70.3 13395 12055 190 1800 51.2 92.1 16948 15254 184 2800 53.3 149.1 25494 22945 171 4750 56.6 268.8 40182 36164 150 BXRC-40E10K0-C-8x 80 650 64.4 41.9 8328 7495 199 975 65.6 64.0 12438 11194 194 1300 66.7 86.7 16515 14863 190 1710 68.0 116.4 21351 19216 183 2600 70.7 183.9 31433 28290 171 4750 75.8 360.1 52576 47319 146 BXRC-40E10K0-D-8x 80 850 35.1 29.9 5940 5346 199 1275 35.8 45.6 8872 7985 194 1700 36.4 61.9 11781 10603 190 2100 36.9 77.6 14353 12917 185 3400 38.6 131.1 22422 20180 171 5500 40.7 224.1 33994 30594 152 BXRC-40G10K0-B-8x 90 700 48.5 34.0 5635 5072 166 1050 49.4 51.9 8416 7575 162 1400 50.2 70.3 11175 10058 159 1800 51.2 92.1 14140 12726 154 2800 53.3 149.1 21269 19143 143 4750 56.6 268.8 33523 30171 125 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-40G10K0-C-8x 90 650 64.4 41.9 6948 6253 166 975 65.6 64.0 10377 9339 162 1300 66.7 86.7 13778 12400 159 1710 68.0 116.4 17813 16032 153 2600 70.7 183.9 26224 23602 143 4750 75.8 360.1 43864 39477 122 BXRC-40G10K0-D-8x 90 850 35.1 29.9 4956 4460 166 1275 35.8 45.6 7402 6662 162 1700 36.4 61.9 9828 8846 159 2100 36.9 77.6 11974 10777 154 3400 38.6 131.1 18706 16836 143 5500 40.7 224.1 28360 25524 127 BXRC-50C10K1-B-8x 70 700 48.5 34.0 7102 6392 209 1050 49.4 51.9 10607 9546 204 1400 50.2 70.3 14084 12675 200 1800 51.2 92.1 17820 16038 194 2800 53.3 149.1 26805 24125 180 4750 56.6 268.8 42248 38023 157 BXRC-50C10K1-C-8x 70 650 64.4 41.9 8756 7880 209 975 65.6 64.0 13078 11770 204 1300 66.7 86.7 17364 15628 200 1710 68.0 116.4 22449 20204 193 2600 70.7 183.9 33049 29744 180 4750 75.8 360.1 55280 49752 154 BXRC-50C10K1-D-8x 70 850 35.1 29.9 6246 5621 209 1275 35.8 45.6 9329 8396 204 1700 36.4 61.9 12386 11148 200 2100 36.9 77.6 15091 13582 195 3400 38.6 131.1 23575 21218 180 5500 40.7 224.1 35742 32168 159 BXRC-50E10K1-B-8x 80 700 48.5 34.0 6832 6148 201 1050 49.4 51.9 10203 9183 197 1400 50.2 70.3 13548 12193 193 1800 51.2 92.1 17142 15428 186 2800 53.3 149.1 25786 23207 173 4750 56.6 268.8 40641 36577 151 BXRC-50E10K1-C-8x 80 650 64.4 41.9 8423 7581 201 975 65.6 64.0 12580 11322 197 1300 66.7 86.7 16704 15033 193 1710 68.0 116.4 21595 19435 186 2600 70.7 183.9 31792 28613 173 4750 75.8 360.1 53177 47859 148 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-50E10K1-D-8x 80 850 35.1 29.9 6008 5407 201 1275 35.8 45.6 8974 8076 197 1700 36.4 61.9 11915 10724 193 2100 36.9 77.6 14517 13065 187 3400 38.6 131.1 22678 20410 173 5500 40.7 224.1 34382 30944 153 BXRC-50G10K1-B-8x 90 700 48.5 34.0 5905 5315 174 1050 49.4 51.9 8820 7938 170 1400 50.2 70.3 11711 10540 166 1800 51.2 92.1 14818 13336 161 2800 53.3 149.1 22289 20060 149 4750 56.6 268.8 35130 31617 131 BXRC-50G10K1-C-8x 90 650 64.4 41.9 7281 6553 174 975 65.6 64.0 10874 9787 170 1300 66.7 86.7 14439 12995 166 1710 68.0 116.4 18667 16800 160 2600 70.7 183.9 27481 24733 149 4750 75.8 360.1 45967 41370 128 BXRC-50G10K1-D-8x 90 850 35.1 29.9 5194 4674 174 1275 35.8 45.6 7757 6981 170 1700 36.4 61.9 10300 9270 167 2100 36.9 77.6 12548 11294 162 3400 38.6 131.1 19603 17643 149 5500 40.7 224.1 29720 26748 133 BXRC-56H10K0-C-8x 97 650 64.4 41.9 6615 5953 158 975 65.6 64.0 9880 8892 154 1300 66.7 86.7 13118 11806 151 1710 68.0 116.4 16959 15263 146 2600 70.7 183.9 24968 22471 136 4750 75.8 360.1 41762 37586 116 BXRC-56H10K0-D-8x 97 850 35.1 29.9 4718 4246 158 1275 35.8 45.6 7047 6342 154 1700 36.4 61.9 9357 8421 151 2100 36.9 77.6 11400 10260 147 3400 38.6 131.1 17809 16028 136 5500 40.7 224.1 27000 24300 120 BXRC-57C10K1-B-8x 70 700 48.5 34.0 6909 6218 203 1050 49.4 51.9 10319 9287 199 1400 50.2 70.3 13701 12331 195 1800 51.2 92.1 17336 15602 188 2800 53.3 149.1 26077 23469 175 4750 56.6 268.8 41100 36990 153 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-57C10K1-C-8x 70 650 64.4 41.9 8518 7666 203 975 65.6 64.0 12722 11450 199 1300 66.7 86.7 16892 15203 195 1710 68.0 116.4 21839 19655 188 2600 70.7 183.9 32151 28936 175 4750 75.8 360.1 53778 48400 149 BXRC-57C10K1-D-8x 70 850 35.1 29.9 6076 5469 203 1275 35.8 45.6 9075 8168 199 1700 36.4 61.9 12050 10845 195 2100 36.9 77.6 14681 13213 189 3400 38.6 131.1 22935 20641 175 5500 40.7 224.1 34771 31294 155 BXRC-57E10K1-B-8x 80 700 48.5 34.0 6561 5905 193 1050 49.4 51.9 9800 8820 189 1400 50.2 70.3 13012 11711 185 1800 51.2 92.1 16464 14818 179 2800 53.3 149.1 24766 22289 166 4750 56.6 268.8 39034 35130 145 BXRC-57E10K1-C-8x 80 650 64.4 41.9 8090 7281 193 975 65.6 64.0 12083 10874 189 1300 66.7 86.7 16043 14439 185 1710 68.0 116.4 20741 18667 178 2600 70.7 183.9 30535 27481 166 4750 75.8 360.1 51074 45967 142 BXRC-57E10K1-D-8x 80 850 35.1 29.9 5771 5194 193 1275 35.8 45.6 8619 7757 189 1700 36.4 61.9 11444 10300 185 2100 36.9 77.6 13943 12548 180 3400 38.6 131.1 21781 19603 166 5500 40.7 224.1 33022 29720 147 BXRC-65C10K1-B-8x 70 700 48.5 34.0 6909 6218 203 1050 49.4 51.9 10319 9287 199 1400 50.2 70.3 13701 12331 195 1800 51.2 92.1 17336 15602 188 2800 53.3 149.1 26077 23469 175 4750 56.6 268.8 41100 36990 153 BXRC-65C10K1-C-8x 70 650 64.4 41.9 8518 7666 203 975 65.6 64.0 12722 11450 199 1300 66.7 86.7 16892 15203 195 1710 68.0 116.4 21839 19655 188 2600 70.7 183.9 32151 28936 175 4750 75.8 360.1 53778 48400 149 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-65C10K1-D-8x 70 850 35.1 29.9 6076 5469 203 1275 35.8 45.6 9075 8168 199 1700 36.4 61.9 12050 10845 195 2100 36.9 77.6 14681 13213 189 3400 38.6 131.1 22935 20641 175 5500 40.7 224.1 34771 31294 155 BXRC-65E10K1-B-8x 80 700 48.5 34.0 6639 5975 195 1050 49.4 51.9 9915 8924 191 1400 50.2 70.3 13165 11849 187 1800 51.2 92.1 16658 14992 181 2800 53.3 149.1 25057 22551 168 4750 56.6 268.8 39493 35544 147 BXRC-65E10K1-C-8x 80 650 64.4 41.9 8185 7366 195 975 65.6 64.0 12225 11002 191 1300 66.7 86.7 16232 14609 187 1710 68.0 116.4 20985 18886 180 2600 70.7 183.9 30894 27805 168 4750 75.8 360.1 51675 46507 144 BXRC-65E10K1-D-8x 80 850 35.1 29.9 5839 5255 195 1275 35.8 45.6 8720 7848 191 1700 36.4 61.9 11579 10421 187 2100 36.9 77.6 14107 12696 182 3400 38.6 131.1 22038 19834 168 5500 40.7 224.1 33411 30070 149 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Electrical Characteristics

Table 5: Electrical Characteristics Part Number Drive Current (mA) Forward Voltage Pulsed, Tc = 25ºC (V) 1, 2, 3, 8 Typical Coefficient of Forward Voltage4 ∆Vf/∆Tc (mV/ºC) Typical Thermal Resistance Junction to Case5,6 Rj-c (ºC/W) Driver Selection Voltages7 (V) Minimum Typical Maximum Vf Min. Hot Tc = 105ºC (V) Vf Max. Cold Tc = -40ºC (V) BXRC-xxx10Kx-B-8x BXRC-xxx10Kx-C-8x BXRC-xxx10Kx-D-8x Notes for Table 5: 1. Parts are tested in pulsed conditions, Tc = 25°C. Pulse width is 10ms. 2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance. 3. Bridgelux maintains a tester tolerance of ± 0.10V on forward voltage measurements. 4. Typical coefficient of forward voltage tolerance is ± 0.1mV for nominal current. 5. Thermal resistance values are based from test data of a 3000K 80 CRI product. 6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal interface material used during testing is not included in the thermal resistance value. 7. Vf min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design and selection over the operating range of the product. 8. This product has been designed and manufactured per IEC 62031:2018. This product has passed dielectric withstand voltage testing at 1140 V. The work- ing voltage designated for the insulation is 70V d.c. The maximum allowable voltage across the array must be determined in the end product application.

Table 6: Eye Safety Risk Group (RG) Classifications Part Number Drive Current (mA) CCT5 2700K/3000K 4000K2 5000K3 6500K4 BXRC-xxx10Kx-B-8x

2145 RG1 RG1 RG1 RG1

2970 RG1 RG1 RG1 RG2

3945 RG1 RG1 RG2 RG2

4750 RG1 RG2 RG2 RG2

1615 RG1 RG1 RG1 RG1

2235 RG1 RG1 RG1 RG2

2970 RG1 RG1 RG2 RG2

2960 RG1 RG1 RG1 RG1

4100 RG1 RG1 RG1 RG2

5500 RG1 RG1 RG2 RG2

Notes for Table 6: 1. Eye safety classification for the use of Bridgelux Vero Series LED arrays is in accordance with specification IEC/TR 62778: Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires. 2. For products classified as RG2 at 4000K, Ethr= 1980 lx. 3. For products classified as RG2 at 5000K Ethr= 1530 lx. 4. For products classified as RG2 at 6500K, Ethr= 1170 lx. 5. Please contact your Bridgelux sales representative for Ethr values at specific drive currents and CCTs not listed.

LED Junction Temperature (Tj) 150°C Storage Temperature -40°C to +105°C Operating Case Temperature1 (Tc) 105°C Soldering Temperature2 300°C or lower for a maximum of 6 seconds BXRC-xxx10Kx-B-8x BXRC-xxx10Kx-C-8x BXRC-xxx10Kx-D-8x Maximum Drive Current3 4750 mA 4750 mA 5500 mA Maximum Peak Pulsed Drive Current4,5 5320 mA 5320 mA 6160 mA Maximum Reverse Voltage6 -90V -120V -65V Notes for Table 7: 1. For IEC 62717 requirement, please consult your Bridgelux sales representative. 2. Refer to Bridgelux Application Note AN31: Assembly Considerations for Bridgelux Vero LED Arrays. 3. Arrays may be driven at higher currents however lumen maintenance may be reduced and warranty will not apply. 4. Per IEC 62031, LED Modules for General Lighting - Safety Specifications, the maximum allowable current when using the Molex Pico Connector is 3150mA. 5. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed current specified. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures. 6. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating provided for reference only. Table 7: Maximum Ratings

Figure 13: Typical Color Spectrum Notes for Figure 13: 1. Color spectra measured at nominal current for Tj = Tc = 25°C. 2. Color spectra shown is 3000K and 80 CRI. 3. Color spectra shown is 4000K and 80 CRI. 4. Color spectra shown is 5000K and 70 CRI. 4. Color spectra shown is 6500K and 70 CRI. 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 110% 400 450 500 550 600 650 700 750 800 Relative Spectral Power Distribution Wavelength (nm) 3000K 4000K 5000K 6500K

Figure 14: Drawing for Vero 29 LED Array Notes for Figure 14: 1. Drawings are not to scale. 2. Drawing dimensions are in millimeters. 3. Unless otherwise specified, tolerances are ± 0.10mm. 4. Mounting holes (4X) are for M3 screws. 5. Bridgelux recommends four tapped holes for mounting screws with 43.0 ± 0.10mm center-to-center spacing. 6. Screws with flat shoulders (pan, dome, button, round, truss, mushroom) provide optimal torque control. Do NOT use flat, countersink, or raised head screws. 7. Solder pads and connector port are labeled “+” and “-“ to denote positive and negative, respectively. 8. It is not necessary to provide electrical connections to both the solder pads and the connector port. Either set may be used depending on application specific design requirements. 9. Refer to Application Notes AN30 and AN31 for product handling, mounting and heat sink recommendations. 10. The optical center of the LED Array is nominally defined by the mechanical center of the array to a tolerance of ± 0.2mm. 11. Bridgelux maintains a flatness of 0.10mm across the mounting surface of the array.

Figure 15: Warm and Neutral White Test Bins in xy Color Space Color Binning Information Bin Code 2700K 3000K 3500K 4000K ANSI Bin (for reference only) (2580K - 2870K) (2870K - 3220K) (3220K - 3710K) (3710K - 4260K) 83 (3 SDCM) (2651K - 2794K) (2968K - 3136K) (3369K - 3586K) (3851K - 4130K) 82 (2 SDCM) (2674K - 2769K) (2995K - 3107K) (3404K - 3548K) (3895K - 4081K) Table 8: Warm and Neutral White xy Bin Coordinates and Associated Typical CCT Bin Code 5000K 5700K 6500K ANSI Bin (for reference only) (4745K - 5311K) (5312K - 6022K) (6022K - 7042K) 84 (4 SDCM) (4801K - 5282K) (5395K- 5970K) (6200K - 6910K) 83 (3 SDCM) (4835K - 5215K) (5460K- 5891K) (6279K -6811K) Note for Tables 8-9: 1. Bridgelux maintains a tolerance of +/- 0.007 on x and y color coordinates in the CIE 1931 color Space. Table 9: Cool White xy Bin Coordinates and Associated Typical CCT (product is hot targeted to Tc = 85°C9 Note: Pulsed Test Conditions, Tc = 25°C Note: Pulsed Test Conditions, Tc = 85°C Figure 16: Cool White Test Bins in xy Color Space 0.34 0.36 0.38 0.4 0.42 0.44 Y X

3 SDCM

2 SDCM

0.3 0.31 0.32 0.33 0.34 0.35 0.36 0.37 0.38 0.39 Y X

4 SDCM

Figure 17: Drawing for Vero 29 Packaging Tray Notes for Figure 17: 1. Dimensions are in millimeters. 2. Drawings are not to scale.

Bridgelux has developed a comprehensive set of application notes and design resources to assist customers in successfully designing with the Vero product family of LED array products. For all available application notes visit www.bridgelux.com. Optical Source Models Optical source models and ray set files are available for all Bridgelux products. For a list of available formats, visit www.bridgelux.com. MINOR PRODUCT CHANGE POLICY The rigorous qualification testing on products offered by Bridgelux provides performance assurance. Slight cosmetic changes that do not affect form, fit, or function may occur as Bridgelux continues product optimization. CAUTION: CHEMICAL EXPOSURE HAZARD Exposure to some chemicals commonly used in luminaire manufacturing and assembly can cause damage to the LED array. Please consult Bridgelux CAUTION: RISK OF BURN Do not touch the Vero LED array during operation. Allow the array to cool for a sufficient period of time before handling. The Vero LED array may reach elevated temperatures such that could burn skin when touched. 3D CAD Models Three dimensional CAD models depicting the product outline of all Bridgelux Vero LED arrays are available in both IGS and STEP formats. Please contact your Bridgelux sales representative for assistance. LM80 LM80 testing has been completed and the LM80 report is now available. Please contact your Bridgelux sales rep- resentative for LM-80 report. CAUTION CONTACT WITH LIGHT EMITTING SURFACE (LES) Avoid any contact with the LES. Do not touch the LES of the LED array or apply stress to the LES (yellow phosphor resin area). Contact may cause damage to the LED array. Optics and reflectors must not be mounted in contact with the LES (yellow phosphor resin area). Optical devices may be mounted on the top surface of the plastic housing of the Vero LED array. Use the mechanical features of the LED array housing, edges and/or mounting holes to locate and secure optical devices as needed. STANDARD TEST CONDITIONS Unless otherwise stated, array testing is performed at the nominal drive current.

About Bridgelux: Bridging Light and Life™ © 2023 Bridgelux, Inc. All rights reserved. Product specifications are subject to change without notice. Bridgelux, the Bridgelux stylized logo design, Vero, V Series and V Series HD are registered trademarks, and Decor Series is a trademark of Bridgelux, Inc. All other trademarks are the property of their respective owners. Bridgelux Gen 8 Vero 29 Array Series Product Data Sheet DS423 Rev. E (08/2023)

46410 Fremont Boulevard

Fremont, CA 94538 U.S.A. Tel (925) 583-8400 www.bridgelux.com At Bridgelux, we help companies, industries and people experience the power and possibility of light. Since 2002, we’ve designed LED solutions that are high performing, energy efficient, cost effective and easy to integrate. Our focus is on light’s impact on human behavior, delivering products that create better environments, experiences and returns—both experiential and financial. And our patented technology drives new platforms for commercial and industrial luminaires. For more information about the company, please visit bridgelux.com twitter.com/Bridgelux facebook.com/Bridgelux youtube.com/user/Bridgelux linkedin.com/company/bridgelux-inc-_2 WeChat ID: BridgeluxInChina