The Vero® Series is a revolutionary advancement in chip on board (COB) light source technology and innovation, simplifying the luminaire design and manufacturing processes. Vero Chip on Board (COB) LED arrays are available in four LES configurations, engineered to enable new degrees of flexibility and reliability over a broad range of electrical currents. Vero arrays deliver increased lumen density to enable improved beam control and precision lighting with 2 and 3 SDCM color control standard for clean and consistent uniform lighting. Vero products include an onboard connector port that enables a solder-free electrical interconnect, and simple mounting features for plug-and-play installation. Vero® Series

Features

  • On board connector port
  • Top side part number markings
  • Efficacy of 178 lm/W typical, 3000K 80 CRI
  • Reliable operation at up to 3x nominal current, 30% increase in maximum lumens per LES size
  • Wide selection of CCT options (2700K-6500K) with minimum 70, 80 and 90 CRI options
  • Uniform high-quality illumination
  • 2 and 3 SDCM binning options (2700K – 4000K)
  • Forward voltage bin codes (backside marking)
  • Thermally isolated solder pads
  • 10-Year warranty Benefits
  • Solder free installation and field upgradability
  • Improved inventory management and quality control
  • Enables high efficiency lighting systems and lower operating costs
  • Supports the trend toward luminaire miniaturization and delivers enhanced optical control
  • Design flexibility for a broad range of lighting

applications

  • Clean white light without pixelation
  • Uniform consistent white light
  • Design flexibility for multi-source applications
  • Enhanced ease of use and installation
  • Design with confidence

The part number designation for Bridgelux Vero LED arrays is explained as follows: 1 2 3 4 5 6 7 8 9 10 11 – 12 – 13 14 Product Family CCT Bin Options 2 = 2 SDCM 3 = 3 SDCM 4 = 4 SDCM CRI C = 70 CRI min. E = 80 CRI min. G = 90 CRI min. Array Configuration 27 = 2,700K 30 = 3,000K 35 = 3,500K 40 = 4,000K 50 = 5,000K 57 = 5,700K 65 = 6,500K BXRC – 30 E 200 0 – C – 8 3 Optional Molex Pico-EZmate™ connector harness (sold separately) Color Targeting Designator 0 = Cold Targeted 1 = Hot Targeted C = Decor Series Showcase Target Gen. 8Nominal CCT Flux Indicator 200x = 2000 lm Vero 13 is the second smallest form factor in the Vero family of the next generation solid state light sources. In addition to delivering the performance and light quality required for many lighting applications, Vero incorporates several features to simplify the design integration and manufacturing process, accelerate time to market and reduce system costs. Please visit www.bridgelux.com for more information on the Vero Series family of products. 2D Bar code provides full manufacturing traceability Polarity indication marks simplify manufacturing operator instructions Optics location/mounting features Mounting holes Zhaga Book 3 compatible mounting locations Solderless connector port enables simplified manufacturing processes, reduced inventory carrying costs and can enable field upgradability Thermally isolated solder pads reduce manufacturing cycle time and complexity Tc Measurement point Correlates to the true case temperature on the back surface of the LED array Radial die configuration improves lumen density and beam control Top side part number marking improves inventory management and outgoing quality control

The following product configurations are available: Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-27E2000-B-8x 2700 80 350 1963 1767 33.4 11.7 168 BXRC-27E2000-C-8x 2700 80 500 2805 2524 33.4 16.7 168 BXRC-27E2000-D-8x 2700 80 400 2068 1861 30.9 12.4 167 BXRC-27G2000-B-8x 2700 90 350 1620 1458 33.4 11.7 139 BXRC-27G2000-C-8x 2700 90 500 2314 2082 33.4 16.7 139 BXRC-27G2000-D-8x 2700 90 400 1706 1535 30.9 12.4 138 BXRC-27G20H0-B-8x 2700 90 350 1690 1521 33.4 11.7 145 BXRC-27G20H0-C-8x 2700 90 500 2414 2172 33.4 16.7 145 BXRC-27G20H0-D-8x 2700 90 400 1780 1602 30.9 12.4 144 BXRC-30C2001-B-8x 3000 70 350 2184 1966 33.4 11.7 187 BXRC-30C2001-C-8x 3000 70 500 3120 2808 33.4 16.7 187 BXRC-30C2001-D-8x 3000 70 400 2300 2070 30.9 12.4 186 BXRC-30E2000-B-8x 3000 80 350 2086 1877 33.4 11.7 178 BXRC-30E2000-C-8x 3000 80 500 2980 2682 33.4 16.7 178 BXRC-30E2000-D-8x 3000 80 400 2197 1977 30.9 12.4 178 BXRC-30G2000-B-8x 3000 90 350 1693 1524 33.4 11.7 145 BXRC-30G2000-C-8x 3000 90 500 2419 2177 33.4 16.7 145 BXRC-30G2000-D-8x 3000 90 400 1783 1605 30.9 12.4 144 BXRC-30G20H0-B-8x 3000 90 350 1773 1596 33.4 11.7 152 BXRC-30G20H0-C-8x 3000 90 500 2533 2280 33.4 16.7 152 BXRC-30G20H0-D-8x 3000 90 400 1867 1681 30.9 12.4 151 BXRC-35E2000-B-8x 3500 80 350 2135 1922 33.4 11.7 183 BXRC-35E2000-C-8x 3500 80 500 3050 2745 33.4 16.7 183 BXRC-35E2000-D-8x 3500 80 400 2249 2024 30.9 12.4 182 BXRC-35G2000-B-8x 3500 90 350 1755 1579 33.4 11.7 150 BXRC-35G2000-C-8x 3500 90 500 2507 2256 33.4 16.7 150 BXRC-35G2000-D-8x 3500 90 400 1848 1663 30.9 12.4 150 BXRC-40C2001-B-8x 4000 70 350 2246 2021 33.4 11.7 192 BXRC-40C2001-C-8x 4000 70 500 3208 2887 33.4 16.7 192 BXRC-40C2001-D-8x 4000 70 400 2365 2129 30.9 12.4 191 BXRC-40E2000-B-8x 4000 80 350 2147 1933 33.4 11.7 184 BXRC-40E2000-C-8x 4000 80 500 3068 2761 33.4 16.7 184 BXRC-40E2000-D-8x 4000 80 400 2262 2035 30.9 12.4 183 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are minimums for all products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test.

Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-40G2000-B-8x 4000 90 350 1792 1612 33.4 11.7 153 BXRC-40G2000-C-8x 4000 90 500 2559 2303 33.4 16.7 153 BXRC-40G2000-D-8x 4000 90 400 1887 1698 30.9 12.4 153 BXRC-50C2001-B-8x 5000 70 350 2258 2032 33.4 11.7 193 BXRC-50C2001-C-8x 5000 70 500 3225 2903 33.4 16.7 193 BXRC-50C2001-D-8x 5000 70 400 2378 2140 30.9 12.4 192 BXRC-50E2001-B-8x 5000 80 350 2172 1955 33.4 11.7 186 BXRC-50E2001-C-8x 5000 80 500 3103 2792 33.4 16.7 186 BXRC-50E2001-D-8x 5000 80 400 2287 2059 30.9 12.4 185 BXRC-50G2001-B-8x 5000 90 350 1877 1690 33.4 11.7 161 BXRC-50G2001-C-8x 5000 90 500 2682 2414 33.4 16.7 161 BXRC-50G2001-D-8x 5000 90 400 1977 1780 30.9 12.4 160 BXRC-57C2001-B-8x 5700 70 350 2196 1977 33.4 11.7 188 BXRC-57C2001-C-8x 5700 70 500 3138 2824 33.4 16.7 188 BXRC-57C2001-D-8x 5700 70 400 2313 2082 30.9 12.4 187 BXRC-57E2001-B-8x 5700 80 350 2086 1877 33.4 11.7 178 BXRC-57E2001-C-8x 5700 80 500 2980 2682 33.4 16.7 178 BXRC-57E2001-D-8x 5700 80 400 2197 1977 30.9 12.4 178 BXRC-65C2001-B-8x 6500 70 350 2196 1977 33.4 11.7 188 BXRC-65C2001-C-8x 6500 70 500 3138 2824 33.4 16.7 188 BXRC-65C2001-D-8x 6500 70 400 2313 2082 30.9 12.4 187 BXRC-65E2001-B-8x 6500 80 350 2111 1899 33.4 11.7 181 BXRC-65E2001-C-8x 6500 80 500 3015 2714 33.4 16.7 181 BXRC-65E2001-D-8x 6500 80 400 2223 2001 30.9 12.4 180 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are minimums for all products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test.

Table 2: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-27E2000-B-8x 2700 80 350 1767 1590 32.7 11.4 154 BXRC-27E2000-C-8x 2700 80 500 2524 2272 32.7 16.3 154 BXRC-27E2000-D-8x 2700 80 400 1861 1675 30.2 12.1 154 BXRC-27G2000-B-8x 2700 90 350 1458 1312 32.7 11.4 127 BXRC-27G2000-C-8x 2700 90 500 2082 1874 32.7 16.3 127 BXRC-27G2000-D-8x 2700 90 400 1535 1382 30.2 12.1 127 BXRC-27G20H0-B-8x 2700 90 350 1521 1369 32.7 11.4 133 BXRC-27G20H0-C-8x 2700 90 500 2172 1955 32.7 16.3 133 BXRC-27G20H0-D-8x 2700 90 400 1602 1441 30.2 12.1 132 BXRC-30C2001-B-8x 3000 70 350 1966 1769 32.7 11.4 172 BXRC-30C2001-C-8x 3000 70 500 2808 2527 32.7 16.3 172 BXRC-30C2001-D-8x 3000 70 400 2070 1863 30.2 12.1 171 BXRC-30E2000-B-8x 3000 80 350 1877 1690 32.7 11.4 164 BXRC-30E2000-C-8x 3000 80 500 2682 2414 32.7 16.3 164 BXRC-30E2000-D-8x 3000 80 400 1977 1780 30.2 12.1 164 BXRC-30G2000-B-8x 3000 90 350 1524 1372 32.7 11.4 133 BXRC-30G2000-C-8x 3000 90 500 2177 1959 32.7 16.3 133 BXRC-30G2000-D-8x 3000 90 400 1605 1445 30.2 12.1 133 BXRC-30G20H0-B-8x 3000 90 350 1596 1436 32.7 11.4 140 BXRC-30G20H0-C-8x 3000 90 500 2280 2052 32.7 16.3 140 BXRC-30G20H0-D-8x 3000 90 400 1681 1513 30.2 12.1 139 BXRC-35E2000-B-8x 3500 80 350 1922 1729 32.7 11.4 168 BXRC-35E2000-C-8x 3500 80 500 2745 2471 32.7 16.3 168 BXRC-35E2000-D-8x 3500 80 400 2024 1821 30.2 12.1 167 BXRC-35G2000-B-8x 3500 90 350 1579 1421 32.7 11.4 138 BXRC-35G2000-C-8x 3500 90 500 2256 2030 32.7 16.3 138 BXRC-35G2000-D-8x 3500 90 400 1663 1497 30.2 12.1 138 BXRC-40C2001-B-8x 4000 70 350 2021 1819 32.7 11.4 177 BXRC-40C2001-C-8x 4000 70 500 2887 2598 32.7 16.3 177 BXRC-40C2001-D-8x 4000 70 400 2129 1916 30.2 12.1 176 BXRC-40E2000-B-8x 4000 80 350 1933 1739 32.7 11.4 169 BXRC-40E2000-C-8x 4000 80 500 2761 2485 32.7 16.3 169 BXRC-40E2000-D-8x 4000 80 400 2035 1832 30.2 12.1 168 BXRC-40G2000-B-8x 4000 90 350 1612 1451 32.7 11.4 141 BXRC-40G2000-C-8x 4000 90 500 2303 2073 32.7 16.3 141 BXRC-40G2000-D-8x 4000 90 400 1698 1528 30.2 12.1 140 Notes for Table 2: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.

Table 2: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-50C2001-B-8x 5000 70 350 2032 1829 32.7 11.4 178 BXRC-50C2001-C-8x 5000 70 500 2903 2613 32.7 16.3 178 BXRC-50C2001-D-8x 5000 70 400 2140 1926 30.2 12.1 177 BXRC-50E2001-B-8x 5000 80 350 1955 1759 32.7 11.4 171 BXRC-50E2001-C-8x 5000 80 500 2792 2513 32.7 16.3 171 BXRC-50E2001-D-8x 5000 80 400 2059 1853 30.2 12.1 170 BXRC-50G2001-B-8x 5000 90 350 1690 1521 32.7 11.4 148 BXRC-50G2001-C-8x 5000 90 500 2414 2172 32.7 16.3 148 BXRC-50G2001-D-8x 5000 90 400 1780 1602 30.2 12.1 147 BXRC-57C2001-B-8x 5700 70 350 1977 1779 32.7 11.4 173 BXRC-57C2001-C-8x 5700 70 500 2824 2542 32.7 16.3 173 BXRC-57C2001-D-8x 5700 70 400 2082 1874 30.2 12.1 172 BXRC-57E2001-B-8x 5700 80 350 1877 1690 32.7 11.4 164 BXRC-57E2001-C-8x 5700 80 500 2682 2414 32.7 16.3 164 BXRC-57E2001-D-8x 5700 80 400 1977 1780 30.2 12.1 164 BXRC-65C2001-B-8x 6500 70 350 1977 1779 32.7 11.4 173 BXRC-65C2001-C-8x 6500 70 500 2824 2542 32.7 16.3 173 BXRC-65C2001-D-8x 6500 70 400 2082 1874 30.2 12.1 172 BXRC-65E2001-B-8x 6500 80 350 1899 1710 32.7 11.4 166 BXRC-65E2001-C-8x 6500 80 500 2714 2442 32.7 16.3 166 BXRC-65E2001-D-8x 6500 80 400 2001 1801 30.2 12.1 165 Notes for Table 2: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.

Performance at Commonly Used Drive Currents Vero LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. Vero may also be driven at other drive currents dependent on specific application design requirements. The performance at any drive current can be derived from the current vs. voltage characteristics shown in Figures 1, 2 & 3 and the flux vs. current characteristics shown in Figures 4, 5 & 6. The performance at commonly used drive currents is summarized in Table 3. Table 3: Product Performance at Commonly Used Drive Currents Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-27E2000-B-8x 80 175 32.4 5.7 1019 917 179 260 32.9 8.6 1476 1329 173 350 33.4 11.7 1963 1767 168 450 33.9 15.3 2478 2230 162 700 35.2 24.6 3750 3375 152 1250 37.6 47.0 6363 5727 135 BXRC-27E2000-C-8x 80 250 32.5 8.1 1455 1310 179 375 33.0 12.4 2128 1916 172 500 33.4 16.7 2805 2524 168 630 33.9 21.4 3473 3126 163 1000 35.2 35.2 5357 4821 152 1750 37.5 65.7 8928 8035 136 BXRC-27E2000-D-8x 80 200 30.0 6.0 1073 965 179 300 30.4 9.1 1569 1412 172 400 30.9 12.3 2068 1861 168 500 31.3 15.6 2542 2287 163 800 32.5 26.0 3950 3555 152 1250 34.1 42.7 5947 5352 139 BXRC-27G2000-B-8x 90 175 32.4 5.7 840 756 148 260 32.9 8.6 1218 1096 142 350 33.4 11.7 1620 1458 139 450 33.9 15.3 2044 1840 134 700 35.2 24.6 3094 2784 126 1250 37.6 47.0 5250 4725 112 BXRC-27G2000-C-8x 90 250 32.5 8.1 1200 1080 148 375 33.0 12.4 1756 1580 142 500 33.4 16.7 2314 2082 138 630 33.9 21.4 2866 2579 134 1000 35.2 35.2 4420 3978 126 1750 37.5 65.7 7366 6629 112 BXRC-27G2000-D-8x 90 200 30.0 6.0 885 797 148 300 30.4 9.1 1295 1165 142 400 30.9 12.3 1706 1535 138 500 31.3 15.6 2097 1887 134 800 32.5 26.0 3258 2933 125 1250 34.1 42.7 4906 4416 115 Notes for Table 3: 1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 3: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-27G20H0-B-8x 90 175 32.4 5.7 877 789 154 260 32.9 8.6 1271 1144 149 350 33.4 11.7 1690 1521 145 450 33.9 15.3 2133 1920 140 700 35.2 24.6 3227 2905 131 1250 37.6 47.0 5476 4929 117 BXRC-27G20H0-C-8x 90 250 32.5 8.1 1252 1127 154 375 33.0 12.4 1832 1649 148 500 33.4 16.7 2414 2172 144 630 33.9 21.4 2989 2690 140 1000 35.2 35.2 4610 4149 131 1750 37.5 65.7 7684 6916 117 BXRC-27G20H0-D-8x 90 200 30.0 6.0 923 831 154 300 30.4 9.1 1350 1215 148 400 30.9 12.3 1780 1602 144 500 31.3 15.6 2187 1969 140 800 32.5 26.0 3399 3059 131 1250 34.1 42.7 5118 4606 120 BXRC-30C2001-B-8x 70 175 32.4 5.7 1133 1020 200 260 32.9 8.6 1643 1478 192 350 33.4 11.7 2184 1966 187 450 33.9 15.3 2757 2481 181 700 35.2 24.6 4172 3755 169 1250 37.6 47.0 7079 6371 151 BXRC-30C2001-C-8x 70 250 32.5 8.1 1619 1457 199 375 33.0 12.4 2368 2131 192 500 33.4 16.7 3120 2808 187 630 33.9 21.4 3864 3478 181 1000 35.2 35.2 5960 5364 169 1750 37.5 65.7 9933 8939 151 BXRC-30C2001-D-8x 70 200 30.0 6.0 1193 1074 199 300 30.4 9.1 1746 1571 191 400 30.9 12.3 2300 2070 186 500 31.3 15.6 2828 2545 181 800 32.5 26.0 4394 3954 169 1250 34.1 42.7 6616 5954 155 BXRC-30E2000-B-8x 80 175 32.4 5.7 1082 974 191 260 32.9 8.6 1569 1412 183 350 33.4 11.7 2086 1877 178 450 33.9 15.3 2633 2370 172 700 35.2 24.6 3984 3586 162 1250 37.6 47.0 6761 6085 144 Notes for Table 3: 1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Table 3: Product Performance at Commonly Used Drive Currents (Continued) Performance at Commonly Used Drive Currents Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-30E2000-C-8x 80 250 32.5 8.1 1546 1391 190 375 33.0 12.4 2261 2035 183 500 33.4 16.7 2980 2682 178 630 33.9 21.4 3691 3321 173 1000 35.2 35.2 5692 5123 162 1750 37.5 65.7 9486 8538 144 BXRC-30E2000-D-8x 80 200 30.0 6.0 1140 1026 190 300 30.4 9.1 1667 1500 183 400 30.9 12.3 2197 1977 178 500 31.3 15.6 2700 2430 173 800 32.5 26.0 4196 3777 161 1250 34.1 42.7 6319 5687 148 BXRC-30G2000-B-8x 90 175 32.4 5.7 878 791 155 260 32.9 8.6 1273 1146 149 350 33.4 11.7 1693 1524 145 450 33.9 15.3 2137 1924 140 700 35.2 24.6 3234 2911 131 1250 37.6 47.0 5488 4939 117 BXRC-30G2000-C-8x 90 250 32.5 8.1 1255 1129 155 375 33.0 12.4 1836 1652 149 500 33.4 16.7 2419 2177 145 630 33.9 21.4 2996 2696 140 1000 35.2 35.2 4621 4158 131 1750 37.5 65.7 7701 6931 117 BXRC-30G2000-D-8x 90 200 30.0 6.0 925 833 154 300 30.4 9.1 1353 1218 148 400 30.9 12.3 1783 1605 145 500 31.3 15.6 2192 1973 140 800 32.5 26.0 3406 3066 131 1250 34.1 42.7 5129 4616 120 BXRC-30G20H0-B-8x 90 175 32.4 5.7 920 828 162 260 32.9 8.6 1333 1200 156 350 33.4 11.7 1773 1596 152 450 33.9 15.3 2238 2014 147 700 35.2 24.6 3387 3048 138 1250 37.6 47.0 5747 5172 122 BXRC-30G20H0-C-8x 90 250 32.5 8.1 1314 1183 162 375 33.0 12.4 1922 1730 156 500 33.4 16.7 2533 2280 152 630 33.9 21.4 3137 2823 147 1000 35.2 35.2 4838 4354 137 1750 37.5 65.7 8063 7257 123 Notes for Table 3: 1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 3: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-30G20H0-D-8x 90 200 30.0 6.0 969 872 162 300 30.4 9.1 1417 1275 155 400 30.9 12.3 1867 1681 151 500 31.3 15.6 2295 2066 147 800 32.5 26.0 3567 3210 137 1250 34.1 42.7 5371 4834 126 BXRC-35E2000-B-8x 80 175 32.4 5.7 1108 997 195 260 32.9 8.6 1606 1445 188 350 33.4 11.7 2135 1922 183 450 33.9 15.3 2695 2426 177 700 35.2 24.6 4078 3670 166 1250 37.6 47.0 6920 6228 147 BXRC-35E2000-C-8x 80 250 32.5 8.1 1582 1424 195 375 33.0 12.4 2315 2083 187 500 33.4 16.7 3050 2745 182 630 33.9 21.4 3777 3400 177 1000 35.2 35.2 5826 5243 165 1750 37.5 65.7 9710 8739 148 BXRC-35E2000-D-8x 80 200 30.0 6.0 1167 1050 195 300 30.4 9.1 1706 1536 187 400 30.9 12.3 2249 2024 182 500 31.3 15.6 2764 2488 177 800 32.5 26.0 4295 3866 165 1250 34.1 42.7 6467 5821 152 BXRC-35G2000-B-8x 90 175 32.4 5.7 910 819 160 260 32.9 8.6 1320 1188 154 350 33.4 11.7 1755 1579 150 450 33.9 15.3 2215 1993 145 700 35.2 24.6 3352 3016 136 1250 37.6 47.0 5687 5118 121 BXRC-35G2000-C-8x 90 250 32.5 8.1 1300 1170 160 375 33.0 12.4 1902 1712 154 500 33.4 16.7 2507 2256 150 630 33.9 21.4 3104 2794 145 1000 35.2 35.2 4788 4309 136 1750 37.5 65.7 7980 7182 121 BXRC-35G2000-D-8x 90 200 30.0 6.0 959 863 160 300 30.4 9.1 1402 1262 154 400 30.9 12.3 1848 1663 150 500 31.3 15.6 2272 2044 145 800 32.5 26.0 3530 3177 136 1250 34.1 42.7 5315 4784 125 Notes for Table 3: 1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 3: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-40C2001-B-8x 70 175 32.4 5.7 1165 1048 205 260 32.9 8.6 1689 1520 197 350 33.4 11.7 2246 2021 192 450 33.9 15.3 2834 2551 186 700 35.2 24.6 4289 3860 174 1250 37.6 47.0 7278 6550 155 BXRC-40C2001-C-8x 70 250 32.5 8.1 1664 1498 205 375 33.0 12.4 2434 2191 197 500 33.4 16.7 3208 2887 192 630 33.9 21.4 3973 3575 186 1000 35.2 35.2 6127 5514 174 1750 37.5 65.7 10212 9191 155 BXRC-40C2001-D-8x 70 200 30.0 6.0 1227 1104 205 300 30.4 9.1 1795 1615 197 400 30.9 12.3 2365 2129 192 500 31.3 15.6 2907 2616 186 800 32.5 26.0 4517 4066 174 1250 34.1 42.7 6802 6122 159 BXRC-40E2000-B-8x 80 175 32.4 5.7 1114 1003 196 260 32.9 8.6 1615 1453 189 350 33.4 11.7 2147 1933 184 450 33.9 15.3 2711 2439 178 700 35.2 24.6 4102 3691 167 1250 37.6 47.0 6960 6264 148 BXRC-40E2000-C-8x 80 250 32.5 8.1 1591 1432 196 375 33.0 12.4 2328 2095 188 500 33.4 16.7 3068 2761 184 630 33.9 21.4 3799 3419 178 1000 35.2 35.2 5859 5273 166 1750 37.5 65.7 9765 8789 149 BXRC-40E2000-D-8x 80 200 30.0 6.0 1173 1056 196 300 30.4 9.1 1716 1545 188 400 30.9 12.3 2262 2035 183 500 31.3 15.6 2780 2502 178 800 32.5 26.0 4320 3888 166 1250 34.1 42.7 6505 5854 152 BXRC-40G2000-B-8x 90 175 32.4 5.7 929 836 164 260 32.9 8.6 1347 1213 157 350 33.4 11.7 1792 1612 153 450 33.9 15.3 2261 2035 148 700 35.2 24.6 3422 3080 139 1250 37.6 47.0 5806 5226 124 Notes for Table 3: 1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 3: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-40G2000-C-8x 90 250 32.5 8.1 1328 1195 164 375 33.0 12.4 1942 1748 157 500 33.4 16.7 2559 2303 153 630 33.9 21.4 3170 2853 148 1000 35.2 35.2 4888 4400 139 1750 37.5 65.7 8147 7332 124 BXRC-40G2000-D-8x 90 200 30.0 6.0 979 881 163 300 30.4 9.1 1432 1289 157 400 30.9 12.3 1887 1698 153 500 31.3 15.6 2319 2087 148 800 32.5 26.0 3604 3244 139 1250 34.1 42.7 5427 4884 127 BXRC-50C2001-B-8x 70 175 32.4 5.7 1171 1054 206 260 32.9 8.6 1698 1528 198 350 33.4 11.7 2258 2032 193 450 33.9 15.3 2850 2565 187 700 35.2 24.6 4312 3881 175 1250 37.6 47.0 7318 6586 156 BXRC-50C2001-C-8x 70 250 32.5 8.1 1673 1506 206 375 33.0 12.4 2448 2203 198 500 33.4 16.7 3225 2903 193 630 33.9 21.4 3994 3595 187 1000 35.2 35.2 6161 5545 175 1750 37.5 65.7 10268 9241 156 BXRC-50C2001-D-8x 70 200 30.0 6.0 1234 1110 206 300 30.4 9.1 1805 1624 198 400 30.9 12.3 2378 2140 193 500 31.3 15.6 2923 2631 187 800 32.5 26.0 4542 4088 175 1250 34.1 42.7 6839 6155 160 BXRC-50E2001-B-8x 80 175 32.4 5.7 1127 1014 198 260 32.9 8.6 1633 1470 191 350 33.4 11.7 2172 1955 186 450 33.9 15.3 2741 2467 180 700 35.2 24.6 4148 3734 168 1250 37.6 47.0 7039 6335 150 BXRC-50E2001-C-8x 80 250 32.5 8.1 1610 1449 198 375 33.0 12.4 2355 2119 190 500 33.4 16.7 3103 2792 186 630 33.9 21.4 3842 3458 180 1000 35.2 35.2 5926 5334 168 1750 37.5 65.7 9877 8889 150 Notes for Table 3: 1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 3: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-50E2001-D-8x 80 200 30.0 6.0 1187 1068 198 300 30.4 9.1 1736 1562 190 400 30.9 12.3 2287 2059 185 500 31.3 15.6 2812 2530 180 800 32.5 26.0 4369 3932 168 1250 34.1 42.7 6579 5921 154 BXRC-50G2001-B-8x 90 175 32.4 5.7 974 877 172 260 32.9 8.6 1412 1271 165 350 33.4 11.7 1877 1690 161 450 33.9 15.3 2370 2133 155 700 35.2 24.6 3586 3227 146 1250 37.6 47.0 6085 5476 129 BXRC-50G2001-C-8x 90 250 32.5 8.1 1391 1252 171 375 33.0 12.4 2035 1832 165 500 33.4 16.7 2682 2414 160 630 33.9 21.4 3321 2989 155 1000 35.2 35.2 5123 4610 145 1750 37.5 65.7 8538 7684 130 BXRC-50G2001-D-8x 90 200 30.0 6.0 1026 923 171 300 30.4 9.1 1500 1350 164 400 30.9 12.3 1977 1780 160 500 31.3 15.6 2430 2187 155 800 32.5 26.0 3777 3399 145 1250 34.1 42.7 5687 5118 133 BXRC-57C2001-B-8x 70 175 32.4 5.7 1139 1026 201 260 32.9 8.6 1652 1487 193 350 33.4 11.7 2196 1977 188 450 33.9 15.3 2772 2495 182 700 35.2 24.6 4195 3776 170 1250 37.6 47.0 7119 6407 151 BXRC-57C2001-C-8x 70 250 32.5 8.1 1628 1465 200 375 33.0 12.4 2381 2143 193 500 33.4 16.7 3138 2824 188 630 33.9 21.4 3886 3497 182 1000 35.2 35.2 5993 5394 170 1750 37.5 65.7 9989 8990 152 BXRC-57C2001-D-8x 70 200 30.0 6.0 1200 1080 200 300 30.4 9.1 1755 1580 192 400 30.9 12.3 2313 2082 187 500 31.3 15.6 2843 2559 182 800 32.5 26.0 4419 3977 170 1250 34.1 42.7 6653 5988 156 Notes for Table 3: 1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 3: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-57E2001-B-8x 80 175 32.4 5.7 1082 974 191 260 32.9 8.6 1569 1412 183 350 33.4 11.7 2086 1877 178 450 33.9 15.3 2633 2370 172 700 35.2 24.6 3984 3586 162 1250 37.6 47.0 6761 6085 144 BXRC-57E2001-C-8x 80 250 32.5 8.1 1546 1391 190 375 33.0 12.4 2261 2035 183 500 33.4 16.7 2980 2682 178 630 33.9 21.4 3691 3321 173 1000 35.2 35.2 5692 5123 162 1750 37.5 65.7 9486 8538 144 BXRC-57E2001-D-8x 80 200 30.0 6.0 1140 1026 190 300 30.4 9.1 1667 1500 183 400 30.9 12.3 2197 1977 178 500 31.3 15.6 2700 2430 173 800 32.5 26.0 4196 3777 161 1250 34.1 42.7 6319 5687 148 BXRC-65C2001-B-8x 70 175 32.4 5.7 1139 1026 201 260 32.9 8.6 1652 1487 193 350 33.4 11.7 2196 1977 188 450 33.9 15.3 2772 2495 182 700 35.2 24.6 4195 3776 170 1250 37.6 47.0 7119 6407 151 BXRC-65C2001-C-8x 70 250 32.5 8.1 1628 1465 200 375 33.0 12.4 2381 2143 193 500 33.4 16.7 3138 2824 188 630 33.9 21.4 3886 3497 182 1000 35.2 35.2 5993 5394 170 1750 37.5 65.7 9989 8990 152 BXRC-65C2001-D-8x 70 200 30.0 6.0 1200 1080 200 300 30.4 9.1 1755 1580 192 400 30.9 12.3 2313 2082 187 500 31.3 15.6 2843 2559 182 800 32.5 26.0 4419 3977 170 1250 34.1 42.7 6653 5988 156 BXRC-65E2001-B-8x 80 175 32.4 5.7 1095 985 193 260 32.9 8.6 1587 1428 185 350 33.4 11.7 2111 1899 181 450 33.9 15.3 2664 2398 175 700 35.2 24.6 4031 3628 164 1250 37.6 47.0 6840 6156 146 Notes for Table 3: 1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 3: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-65E2001-C-8x 80 250 32.5 8.1 1564 1408 193 375 33.0 12.4 2288 2059 185 500 33.4 16.7 3015 2714 180 630 33.9 21.4 3734 3361 175 1000 35.2 35.2 5759 5183 164 1750 37.5 65.7 9598 8638 146 BXRC-65E2001-D-8x 80 200 30.0 6.0 1153 1038 192 300 30.4 9.1 1687 1518 185 400 30.9 12.3 2223 2001 180 500 31.3 15.6 2732 2459 175 800 32.5 26.0 4246 3821 163 1250 34.1 42.7 6393 5754 150 Notes for Table 3: 1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Electrical Characteristics

Table 4: Electrical Characteristics Part Number Drive Current (mA) Forward Voltage Pulsed, Tc = 25ºC (V) 1, 2, 3, 8 Typical Coefficient of Forward Voltage4 ∆Vf/∆Tc (mV/ºC) Typical Thermal Resistance Junction to Case5,6 Rj-c (ºC/W) Driver Selection Voltages7 (V) Minimum Typical Maximum Vf Min. Hot Tc = 105ºC (V) Vf Max. Cold Tc = -40ºC (V) BXRC-xxx200x-B-8x BXRC-xxx200x-C-8x BXRC-xxx200x-D-8x Notes for Table 4: 1. Parts are tested in pulsed conditions, Tc = 25°C. Pulse width is 10ms. 2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance. 3. Bridgelux maintains a tester tolerance of ± 0.10V on forward voltage measurements. 4. Typical coefficient of forward voltage tolerance is ± 0.1mV for nominal current. 5. Thermal resistance values are based from test data of a 3000K 80 CRI product. 6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal interface material used during testing is not included in the thermal resistance value. 7. Vf min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design and selection over the operating range of the product. 8. This product has been designed and manufactured per IEC 62031:2014. This product has passed dielectric withstand voltage testing at 1140 V. The working voltage designated for the insulation is 70V d.c. The maximum allowable voltage across the array must be determined in the end product application.

Table 5: Eye Safety Risk Group (RG) Classifications Part Number Drive Current (mA) CCT 2700K/3000K 4000K2 5000K3 6500K4 BXRC-xxx200x-B-8x

800 RG1 RG1 RG1 RG1

1110 RG1 RG1 RG1 RG2

1250 RG1 RG1 RG2 RG2

1470 RG1 RG1 RG2 RG2

1750 RG1 RG2 RG2 RG2

865 RG1 RG1 RG1 RG1

1195 RG1 RG1 RG1 RG2

Notes for Table 5: 1. Eye safety classification for the use of Bridgelux V Series LED arrays is in accordance with specification IEC/TR 62778: Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires. 2. For products classified as RG2 at 4000K, Ethr= 1980 lx. 3. For products classified as RG2 at 5000K Ethr= 1530 lx. 4. For products classified as RG2 at 6500K, Ethr= 1170 lx. 5. Please contact your Bridgelux sales representative for Ethr values at specific drive currents and CCTs not listed.

Table 6: Maximum Ratings Parameter Maximum Rating LED Junction Temperature (Tj) 150°C Storage Temperature -40°C to +105°C Operating Case Temperature1 (Tc) 105°C Soldering Temperature2 300°C or lower for a maximum of 6 seconds BXRC-xxx200x-B-8x BXRC-xxx200x-C-8x BXRC-xxx200x-D-8x Maximum Drive Current3 1250 mA 1750 mA 1250 mA Maximum Peak Pulsed Drive Current4 1400 mA 1960 mA 1400 mA Maximum Reverse Voltage5 -60V -60V -55V Notes for Table 6: 1. For IEC 62717 requirement, please consult your Bridgelux sales representative. 2. Refer to Bridgelux Application Note AN31: Assembly Considerations for Bridgelux Vero LED Arrays. 3. Arrays may be driven at higher currents however lumen maintenance may be reduced and warranty will not apply. 4. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed current specified. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures. 5. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating provided for reference only.

Figure 12: Typical Color Spectrum Note for Figure 12: 1. Color spectra measured at nominal current for Tj = Tc = 25°C. 2. Color spectra shown is 3000K and 80 CRI. 3. Color spectra shown is 4000K and 80 CRI. 4. Color spectra shown is 5000K and 70 CRI. 4. Color spectra shown is 6500K and 70 CRI. 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 110% 400 450 500 550 600 650 700 750 800 Relative Spectral Power Distribution Wavelength (nm) 3000K 4000K 5000K 6500K

Figure 13: Drawing for Vero 13 LED Array Notes for Figure 13: 1. Drawings are not to scale. 2. Drawing dimensions are in millimeters. 3. Unless otherwise specified, tolerances are ±0.1mm. 4. Mounting holes (2X) are for M2.5 screws. 5. Bridgelux recommends two tapped holes for mounting screws with 31.4 ± 0.10mm center-to-center spacing. 6. Screws with flat shoulders (pan, dome, button, round, truss, mushroom) provide optimal torque control. Do NOT use flat, countersink, or raised head screws. 7. Solder pads and connector port are labeled “+” and “-“ to denote positive and negative, respectively. 8. It is not necessary to provide electrical connections to both the solder pads and the connector port. Either set may be used depending on application specific design requirements. 9. Refer to Application Notes AN30 and AN31 for product handling, mounting and heat sink recommendations. 10. The optical center of the LED Array is nominally defined by the mechanical center of the array to a tolerance of ± 0.2mm. 11. Bridgelux maintains a flatness of 0.10mm across the mounting surface of the array.

Figure 14: Warm and Neutral White T est Bins in xy Color Space Color Binning Information Bin Code 2700K 3000K 3500K 4000K ANSI Bin (for reference only) (2580K - 2870K) (2870K - 3220K) (3220K - 3710K) (3710K - 4260K) 83 (3 SDCM) (2651K - 2794K) (2968K - 3136K) (3369K - 3586K) (3851K - 4130K) 82 (2 SDCM) (2674K - 2769K) (2995K - 3107K) (3404K - 3548K) (3895K - 4081K) Table 7: Warm and Neutral White xy Bin Coordinates and Associated Typical CCT Bin Code 5000K 5700K 6500K ANSI Bin (for reference only) (4745K - 5311K) (5312K - 6022K) (6022K - 7042K) 84 (4 SDCM) (4801K - 5282K) (5829K - 5481K) (6270K - 6765K) 83 (3 SDCM) (4835K - 5215K) (5490K - 5820K) (6250K - 6745K) Table 8: Cool White xy Bin Coordinates and Associated Typical CCT (product is hot targeted to Tc = 85°C) Note: Pulsed Test Conditions, Tc = 25°C Note: Pulsed Test Conditions, Tc = 25°C Figure 15: Cool White T est Bins in xy Color Space 0.34 0.36 0.38 0.4 0.42 0.44 Y X

3 SDCM

2 SDCM

0.3 0.31 0.32 0.33 0.34 0.35 0.36 0.37 0.38 0.39 Y X

4 SDCM

Figure 16: Drawing for Vero 13 Packaging Tray Notes for Figure 16: 1. Dimensions are in millimeters. 2. Drawings are not to scale.

Bridgelux has developed a comprehensive set of application notes and design resources to assist customers in successfully designing with the Vero product family of LED array products. For all available application notes visit www.bridgelux.com. Optical Source Models Optical source models and ray set files are available for all Bridgelux products. For a list of available formats, visit www.bridgelux.com. MINOR PRODUCT CHANGE POLICY The rigorous qualification testing on products offered by Bridgelux provides performance assurance. Slight cosmetic changes that do not affect form, fit, or function may occur as Bridgelux continues product optimization. CAUTION: CHEMICAL EXPOSURE HAZARD Exposure to some chemicals commonly used in luminaire manufacturing and assembly can cause damage to the LED array. Please consult Bridgelux CAUTION: RISK OF BURN Do not touch the Vero LED array during operation. Allow the array to cool for a sufficient period of time before handling. The Vero LED array may reach elevated temperatures such that could burn skin when touched. 3D CAD Models Three dimensional CAD models depicting the product outline of all Bridgelux Vero LED arrays are available in both IGS and STEP formats. Please contact your Bridgelux sales representative for assistance. LM80 LM80 testing has been completed and the LM80 report is now available. Please contact your Bridgelux sales rep- resentative for LM-80 report. CAUTION CONTACT WITH LIGHT EMITTING SURFACE (LES) Avoid any contact with the LES. Do not touch the LES of the LED array or apply stress to the LES (yellow phosphor resin area). Contact may cause damage to the LED array. Optics and reflectors must not be mounted in contact with the LES (yellow phosphor resin area). Optical devices may be mounted on the top surface of the plastic housing of the Vero LED array. Use the mechanical features of the LED array housing, edges and/or mounting holes to locate and secure optical devices as needed. STANDARD TEST CONDITIONS Unless otherwise stated, array testing is performed at the nominal drive current.

About Bridgelux: Bridging Light and Life™ © 2020 Bridgelux, Inc. All rights reserved. Product specifications are subject to change without notice. Bridgelux, the Bridgelux stylized logo design, Vero, V Series and V Series HD are registered trademarks, and Decor Series is a trademark of Bridgelux, Inc. All other trademarks are the property of their respective owners. Bridgelux Gen 8 Vero 13 Array Series Product Data Sheet DS421 Rev. A (07/2020)

46430 Fremont Boulevard

Fremont, CA 94538 U.S.A. Tel (925) 583-8400 www.bridgelux.com At Bridgelux, we help companies, industries and people experience the power and possibility of light. Since 2002, we’ve designed LED solutions that are high performing, energy efficient, cost effective and easy to integrate. Our focus is on light’s impact on human behavior, delivering products that create better environments, experiences and returns—both experiential and financial. And our patented technology drives new platforms for commercial and industrial luminaires. For more information about the company, please visit bridgelux.com twitter.com/Bridgelux facebook.com/Bridgelux youtube.com/user/Bridgelux linkedin.com/company/bridgelux-inc-_2 WeChat ID: BridgeluxInChina