10 Array
The Vero® Series is a revolutionary advancement in chip on board (COB) light source technology and innovation, simplifying the luminaire design and manufacturing processes. Vero Chip on Board (COB) LED arrays are available in four LES configurations, engineered to enable new degrees of flexibility and reliability over a broad range of electrical currents. Vero arrays deliver increased lumen density to enable improved beam control and precision lighting with 2 and 3 SDCM color control standard for clean and consistent uniform lighting. Vero products include an onboard connector port that enables a solder-free electrical interconnect, and simple mounting features for plug-and-play installation. Vero® Series
Features
- On board connector port
- Top side part number markings
- Efficacy of 178 lm/W typical, 3000K 80 CRI
- Reliable operation at up to 3x nominal current, 30% increase in maximum lumens per LES size
- Wide selection of CCT options (2700K-6500K) with minimum 70, 80 and 90 CRI options
- Uniform high-quality illumination
- 2 and 3 SDCM binning options (2700K – 4000K)
- Forward voltage bin codes (backside marking)
- Thermally isolated solder pads
- 10-Year warranty Benefits
- Solder free installation and field upgradability
- Improved inventory management and quality control
- Enables high efficiency lighting systems and lower operating costs
- Supports the trend toward luminaire miniaturization and delivers enhanced optical control
- Design flexibility for a broad range of lighting
applications
- Clean white light without pixelation
- Uniform consistent white light
- Design flexibility for multi-source applications
- Enhanced ease of use and installation
- Design with confidence
The part number designation for Bridgelux Vero LED arrays is explained as follows: 1 2 3 4 5 6 7 8 9 10 11 – 12 – 13 14 Product Family CCT Bin Options 2 = 2 SDCM 3 = 3 SDCM 4 = 4 SDCM CRI C = 70 CRI min. E = 80 CRI min. G = 90 CRI min. H = 97 CRI typ. Array Configuration 27 = 2,700K 30 = 3,000K 35 = 3,500K 40 = 4,000K 50 = 5,000K 57 = 5,700K 65 = 6,500K BXRC – 30 E 100 0 – C – 8 3 Color Targeting Designator 0 = Cold Targeted 1 = Hot Targeted C = Decor Series Showcase Target Gen. 8Nominal CCT Flux Indicator 100x = 1000 lm Vero 10 is the smallest form factor in the Vero family of next generation solid state light sources. In addition to delivering the performance and light quality required for many lighting applications, Vero incorporates several features to simplify the design integration and manufacturing process, accelerate time to market and reduce system costs. Please visit www.bridgelux.com for more information on the Vero Series family of products. Mounting holes Polarity indication marks simplify manufacturing operator instructions 2D Bar code provides full manufacturing traceability Solderless connector port enables simplified manufacturing processes, reduced inventory carrying costs and can enable field upgradability Thermally isolated solder pads reduce manufacturing cycle time and complexity Tc Measurement point Radial die configuration improves lumen density and beam control Top side part number marking improves inventory management and outgoing quality control Optional Bridgelux Vero wire harness (sold separately)
The following product configurations are available: Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-27E1000-B-8x 2700 80 200 1145 1008 34.2 6.8 167 BXRC-27E1000-C-8x 2700 80 300 1544 1359 30.7 9.2 168 BXRC-27E1000-D-8x 2700 80 250 1043 918 24.9 6.2 168 BXRC-27G1000-B-8x 2700 90 200 945 832 34.2 6.8 138 BXRC-27G1000-C-8x 2700 90 300 1274 1121 30.7 9.2 138 BXRC-27G1000-D-8x 2700 90 250 860 757 24.9 6.2 138 BXRC-27G10H0-B-8x 2700 90 200 986 867 34.2 6.8 144 BXRC-27G10H0-C-8x 2700 90 300 1329 1170 30.7 9.2 144 BXRC-27G10H0-D-8x 2700 90 250 897 790 24.9 6.2 144 BXRC-27H1000-B-8x 2700 97 200 838 737 34.2 6.8 122 BXRC-27H1000-C-8x 2700 97 300 1129 994 30.7 9.2 123 BXRC-27H1000-D-8x 2700 97 250 763 671 24.9 6.2 123 BXRC-30C1001-B-8x 3000 70 200 1274 1121 34.2 6.8 186 BXRC-30C1001-C-8x 3000 70 300 1718 1512 30.7 9.2 187 BXRC-30C1001-D-8x 3000 70 250 1160 1021 24.9 6.2 186 BXRC-30E1000-B-8x 3000 80 200 1217 1071 34.2 6.8 178 BXRC-30E1000-C-8x 3000 80 300 1641 1444 30.7 9.2 178 BXRC-30E1000-D-8x 3000 80 250 1108 975 24.9 6.2 178 BXRC-30G1000-B-8x 3000 90 200 988 869 34.2 6.8 144 BXRC-30G1000-C-8x 3000 90 300 1332 1172 30.7 9.2 145 BXRC-30G1000-D-8x 3000 90 250 899 792 24.9 6.2 144 BXRC-30G10H0-B-8x 3000 90 200 1034 910 34.2 6.8 151 BXRC-30G10H0-C-8x 3000 90 300 1395 1227 30.7 9.2 151 BXRC-30G10H0-D-8x 3000 90 250 942 829 24.9 6.2 151 BXRC-30H1000-B-8x 3000 97 200 895 787 34.2 6.8 131 BXRC-30H1000-C-8x 3000 97 300 1207 1062 30.7 9.2 131 BXRC-30H1000-D-8x 3000 97 250 815 717 24.9 6.2 131 BXRC-35E1000-B-8x 3500 80 200 1246 1096 34.2 6.8 182 BXRC-35E1000-C-8x 3500 80 300 1680 1478 30.7 9.2 182 BXRC-35E1000-D-8x 3500 80 250 1134 998 24.9 6.2 182 BXRC-35G1000-B-8x 3500 90 200 1024 901 34.2 6.8 150 BXRC-35G1000-C-8x 3500 90 300 1380 1215 30.7 9.2 150 BXRC-35G1000-D-8x 3500 90 250 932 820 24.9 6.2 150 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are minimums for all products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal drive current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test.
Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-40C1001-B-8x 4000 70 200 1310 1153 34.2 6.8 192 BXRC-40C1001-C-8x 4000 70 300 1766 1555 30.7 9.2 192 BXRC-40C1001-D-8x 4000 70 250 1193 1050 24.9 6.2 192 BXRC-40E1000-B-8x 4000 80 200 1253 1102 34.2 6.8 183 BXRC-40E1000-C-8x 4000 80 300 1689 1487 30.7 9.2 183 BXRC-40E1000-D-8x 4000 80 250 1141 1004 24.9 6.2 183 BXRC-40G1000-B-8x 4000 90 200 1045 920 34.2 6.8 153 BXRC-40G1000-C-8x 4000 90 300 1409 1240 30.7 9.2 153 BXRC-40G1000-D-8x 4000 90 250 952 837 24.9 6.2 153 BXRC-50C1001-B-8x 5000 70 200 1317 1159 34.2 6.8 193 BXRC-50C1001-C-8x 5000 70 300 1776 1563 30.7 9.2 193 BXRC-50C1001-D-8x 5000 70 250 1199 1055 24.9 6.2 193 BXRC-50E1001-B-8x 5000 80 200 1267 1115 34.2 6.8 185 BXRC-50E1001-C-8x 5000 80 300 1709 1504 30.7 9.2 186 BXRC-50E1001-D-8x 5000 80 250 1154 1015 24.9 6.2 185 BXRC-50G1001-B-8x 5000 90 200 1095 964 34.2 6.8 160 BXRC-50G1001-C-8x 5000 90 300 1477 1300 30.7 9.2 160 BXRC-50G1001-D-8x 5000 90 250 997 878 24.9 6.2 160 BXRC-57C1001-B-8x 5700 70 200 1281 1128 34.2 6.8 187 BXRC-57C1001-C-8x 5700 70 300 1728 1521 30.7 9.2 188 BXRC-57C1001-D-8x 5700 70 250 1167 1027 24.9 6.2 187 BXRC-57E1001-B-8x 5700 80 200 1217 1071 34.2 6.8 178 BXRC-57E1001-C-8x 5700 80 300 1641 1444 30.7 9.2 178 BXRC-57E1001-D-8x 5700 80 250 1108 975 24.9 6.2 178 BXRC-65C1001-B-8x 6500 70 200 1281 1128 34.2 6.8 187 BXRC-65C1001-C-8x 6500 70 300 1728 1521 30.7 9.2 188 BXRC-65C1001-D-8x 6500 70 250 1167 1027 24.9 6.2 187 BXRC-65E1001-B-8x 6500 80 200 1231 1084 34.2 6.8 180 BXRC-65E1001-C-8x 6500 80 300 1660 1461 30.7 9.2 180 BXRC-65E1001-D-8x 6500 80 250 1121 987 24.9 6.2 180 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are minimums for all products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal drive current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test.
Table 2: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-27E1000-B-8x 2700 80 200 1031 907 33.6 6.7 154 BXRC-27E1000-C-8x 2700 80 300 1390 1223 30.1 9.0 154 BXRC-27E1000-D-8x 2700 80 250 939 826 24.4 6.1 154 BXRC-27G1000-B-8x 2700 90 200 850 748 33.6 6.7 127 BXRC-27G1000-C-8x 2700 90 300 1147 1009 30.1 9.0 127 BXRC-27G1000-D-8x 2700 90 250 774 681 24.4 6.1 127 BXRC-27G10H0-B-8x 2700 90 200 887 781 33.6 6.7 132 BXRC-27G10H0-C-8x 2700 90 300 1196 1053 30.1 9.0 132 BXRC-27G10H0-D-8x 2700 90 250 808 711 24.4 6.1 132 BXRC-27H1000-B-8x 2700 97 200 754 663 33.6 6.7 112 BXRC-27H1000-C-8x 2700 97 300 1016 894 30.1 9.0 112 BXRC-27H1000-D-8x 2700 97 250 686 604 24.4 6.1 112 BXRC-30C1001-B-8x 3000 70 200 1147 1009 33.6 6.7 171 BXRC-30C1001-C-8x 3000 70 300 1546 1361 30.1 9.0 171 BXRC-30C1001-D-8x 3000 70 250 1044 919 24.4 6.1 171 BXRC-30E1000-B-8x 3000 80 200 1095 964 33.6 6.7 163 BXRC-30E1000-C-8x 3000 80 300 1477 1300 30.1 9.0 163 BXRC-30E1000-D-8x 3000 80 250 997 878 24.4 6.1 163 BXRC-30G1000-B-8x 3000 90 200 889 782 33.6 6.7 133 BXRC-30G1000-C-8x 3000 90 300 1199 1055 30.1 9.0 133 BXRC-30G1000-D-8x 3000 90 250 809 712 24.4 6.1 133 BXRC-30G10H0-B-8x 3000 90 200 931 819 33.6 6.7 139 BXRC-30G10H0-C-8x 3000 90 300 1255 1105 30.1 9.0 139 BXRC-30G10H0-D-8x 3000 90 250 848 746 24.4 6.1 139 BXRC-30H1000-B-8x 3000 97 200 805 709 33.6 6.7 120 BXRC-30H1000-C-8x 3000 97 300 1086 956 30.1 9.0 120 BXRC-30H1000-D-8x 3000 97 250 733 645 24.4 6.1 120 BXRC-35E1000-B-8x 3500 80 200 1121 987 33.6 6.7 167 BXRC-35E1000-C-8x 3500 80 300 1512 1330 30.1 9.0 167 BXRC-35E1000-D-8x 3500 80 250 1021 898 24.4 6.1 167 BXRC-35G1000-B-8x 3500 90 200 921 811 33.6 6.7 137 BXRC-35G1000-C-8x 3500 90 300 1242 1093 30.1 9.0 137 BXRC-35G1000-D-8x 3500 90 250 839 738 24.4 6.1 137 Notes for Table 2: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are minimums for all products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
Table 2: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-40C1001-B-8x 4000 70 200 1179 1038 33.6 6.7 176 BXRC-40C1001-C-8x 4000 70 300 1590 1399 30.1 9.0 176 BXRC-40C1001-D-8x 4000 70 250 1073 945 24.4 6.1 176 BXRC-40E1000-B-8x 4000 80 200 1128 992 33.6 6.7 168 BXRC-40E1000-C-8x 4000 80 300 1520 1338 30.1 9.0 168 BXRC-40E1000-D-8x 4000 80 250 1027 903 24.4 6.1 168 BXRC-40G1000-B-8x 4000 90 200 941 828 33.6 6.7 140 BXRC-40G1000-C-8x 4000 90 300 1268 1116 30.1 9.0 140 BXRC-40G1000-D-8x 4000 90 250 856 754 24.4 6.1 140 BXRC-50C1001-B-8x 5000 70 200 1186 1043 33.6 6.7 177 BXRC-50C1001-C-8x 5000 70 300 1599 1407 30.1 9.0 177 BXRC-50C1001-D-8x 5000 70 250 1079 950 24.4 6.1 177 BXRC-50E1001-B-8x 5000 80 200 1140 1004 33.6 6.7 170 BXRC-50E1001-C-8x 5000 80 300 1538 1353 30.1 9.0 170 BXRC-50E1001-D-8x 5000 80 250 1038 914 24.4 6.1 170 BXRC-50G1001-B-8x 5000 90 200 986 867 33.6 6.7 147 BXRC-50G1001-C-8x 5000 90 300 1329 1170 30.1 9.0 147 BXRC-50G1001-D-8x 5000 90 250 897 790 24.4 6.1 147 BXRC-57C1001-B-8x 5700 70 200 1153 1015 33.6 6.7 172 BXRC-57C1001-C-8x 5700 70 300 1555 1368 30.1 9.0 172 BXRC-57C1001-D-8x 5700 70 250 1050 924 24.4 6.1 172 BXRC-57E1001-B-8x 5700 80 200 1095 964 33.6 6.7 163 BXRC-57E1001-C-8x 5700 80 300 1477 1300 30.1 9.0 163 BXRC-57E1001-D-8x 5700 80 250 997 878 24.4 6.1 163 BXRC-65C1001-B-8x 6500 70 200 1153 1015 33.6 6.7 172 BXRC-65C1001-C-8x 6500 70 300 1555 1368 30.1 9.0 172 BXRC-65C1001-D-8x 6500 70 250 1050 924 24.4 6.1 172 BXRC-65E1001-B-8x 6500 80 200 1108 975 33.6 6.7 165 BXRC-65E1001-C-8x 6500 80 300 1494 1315 30.1 9.0 165 BXRC-65E1001-D-8x 6500 80 250 1009 888 24.4 6.1 165 Notes for Table 2: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are minimums for all products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
European Product Registry for Energy Labeling The European Product Registry for Energy Labeling (EPREL) is defined in the EU Regulation 2017/1369 to provide import- ant energy efficiency information to consumers. Together with Energy Labeling Regulation ELR (EU) 2019/2015 which was amended by regulation (EU) 2021/340 for energy labelling of light sources, manufacturers are required to declare an ener- gy class based on key technical specifications from each of their product and register it in an open data base managed by EPREL It is now a legal requirement for a vendor of light sources to upload information about their products into the EPREL database before placing these products on the market in the EU. Table 3 below provides a list of part numbers that are in compliance with ELR and are currently listed in the EPREL data- base. At Bridgelux, we are fully committed to supplying products that are compliant with pertinent laws, rules, and obligation imposed by relevant government bodies including the European Energy Labeling regulation. Customers can use these products with full confidence for any projects that fall under the ELR. Table 3: Part numbers registered in European Product Registry for Energy Labeling PART NUMBER1 CCT (K) CRI Current2 (mA) Vf (V) Useful flux3 (Φuse) at 85C (lm) Pow- er (W) Efficacy (lm/W) Energy efficiency class4 Regis- tration No URL to Product Information Sheet in EPREL Database Notes for Table 3: 1. All device listed here must be disposed as e-waste upon its end of life according to local country guideline in each country. 2. For information on performance values at alternative drive conditions. please refer to the Product Selection Guide, Absolute Maximum Rating Table and Performance Curves in this data sheet. 3. For a definition of useful luminous flux (ΦΦuse), please see the ELR regulations at https:/ /tinyurl.com/4b6zvt4m. 4. EPREL requires an arrow symbol containing the letter of the energy efficiency class to be displayed. on technical promotional material. Refer to this energy efficiency class column for specific energy efficiency class on each part number.
European Product Registry for Energy Labeling Table 3: Part numbers registered in European Product Registry for Energy Labeling (Continued) PART NUMBER1 CCT (K) CRI Current2 (mA) Vf (V) Useful flux3 (Φuse) at 85C (lm) Pow- er (W) Efficacy (lm/W) Energy efficiency class4 Regis- tration No URL to Product Information Sheet in EPREL Database Notes for Table 3: 1. All device listed here must be disposed as e-waste upon its end of life according to local country guideline in each country. 2. For information on performance values at alternative drive conditions. please refer to the Product Selection Guide, Absolute Maximum Rating Table and Performance Curves in this data sheet. 3. For a definition of useful luminous flux (ΦΦuse), please see the ELR regulations at https:/ /tinyurl.com/4b6zvt4m. 4. EPREL requires an arrow symbol containing the letter of the energy efficiency class to be displayed. on technical promotional material. Refer to this energy efficiency class column for specific energy efficiency class on each part number.
European Product Registry for Energy Labeling Table 3: Part numbers registered in European Product Registry for Energy Labeling (Continued) PART NUMBER1 CCT (K) CRI Current2 (mA) Vf (V) Useful flux3 (Φuse) at 85C (lm) Pow- er (W) Efficacy (lm/W) Energy efficiency class4 Regis- tration No URL to Product Information Sheet in EPREL Database Notes for Table 3: 1. All device listed here must be disposed as e-waste upon its end of life according to local country guideline in each country. 2. For information on performance values at alternative drive conditions. please refer to the Product Selection Guide, Absolute Maximum Rating Table and Performance Curves in this data sheet. 3. For a definition of useful luminous flux (ΦΦuse), please see the ELR regulations at https:/ /tinyurl.com/4b6zvt4m. 4. EPREL requires an arrow symbol containing the letter of the energy efficiency class to be displayed. on technical promotional material. Refer to this energy efficiency class column for specific energy efficiency class on each part number.
Performance at Commonly Used Drive Currents Vero LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. Vero may also be driven at other drive currents dependent on specific application design requirements. The performance at any drive current can be derived from the current vs. voltage characteristics shown in Figures 1, 2 & 3 and the flux vs. current characteristics shown in Figures 4, 5 & 6. The performance at commonly used drive currents is summarized in Table 4. Table 4: Product Performance at Commonly Used Drive Currents Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-27E1000-B-8x 80 100 32.9 3.3 597 537 181 150 33.6 5.0 872 785 173 200 34.2 6.8 1145 1031 168 270 35.0 9.5 1500 1350 159 400 36.5 14.6 2131 1918 146 500 37.5 18.7 2581 2323 138 BXRC-27E1000-C-8x 80 150 29.6 4.4 805 725 181 225 30.2 6.8 1176 1058 173 300 30.7 9.2 1544 1390 168 360 31.2 11.2 1817 1635 162 600 32.8 19.7 2874 2586 146 1000 35.0 35.0 4400 3960 126 BXRC-27E1000-D-8x 80 125 24.0 3.0 544 489 181 185 24.4 4.5 784 706 174 250 24.9 6.2 1043 939 168 350 25.6 9.0 1412 1271 158 500 26.6 13.3 1940 1746 146 1000 29.1 29.1 3412 3070 117 BXRC-27G1000-B-8x 90 100 32.9 3.3 493 443 150 150 33.6 5.0 719 647 143 200 34.2 6.8 945 850 138 270 35.0 9.5 1238 1114 131 400 36.5 14.6 1758 1582 120 500 37.5 18.7 2129 1917 114 BXRC-27G1000-C-8x 90 150 29.6 4.4 664 598 150 225 30.2 6.8 970 873 143 300 30.7 9.2 1274 1147 138 360 31.2 11.2 1499 1349 134 600 32.8 19.7 2371 2134 120 1000 35.0 35.0 3630 3267 104 BXRC-27G1000-D-8x 90 125 24.0 3.0 448 404 150 185 24.4 4.5 647 582 143 250 24.9 6.2 860 774 138 350 25.6 9.0 1165 1048 130 500 26.6 13.3 1601 1441 120 1000 29.1 29.1 2815 2533 97 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-27G10H0-B-8x 90 100 32.9 3.3 514 462 156 150 33.6 5.0 750 675 149 200 34.2 6.8 986 887 144 270 35.0 9.5 1291 1162 137 400 36.5 14.6 1834 1651 126 500 37.5 18.7 2221 1999 118 BXRC-27G10H0-C-8x 90 150 29.6 4.4 693 624 156 225 30.2 6.8 1012 911 149 300 30.7 9.2 1329 1196 144 360 31.2 11.2 1564 1407 139 600 32.8 19.7 2473 2226 126 1000 35.0 35.0 3787 3408 108 BXRC-27G10H0-D-8x 90 125 24.0 3.0 468 421 156 185 24.4 4.5 675 607 149 250 24.9 6.2 897 808 144 350 25.6 9.0 1215 1093 136 500 26.6 13.3 1670 1503 126 1000 29.1 29.1 2936 2642 101 BXRC-27H1000-B-8x 97 100 32.9 3.3 437 393 133 150 33.6 5.0 638 574 127 200 34.2 6.8 838 754 122 270 35.0 9.5 1097 987 116 400 36.5 14.6 1558 1403 107 500 37.5 18.7 1887 1699 101 BXRC-27H1000-C-8x 97 150 29.8 4.5 592 532 132 225 30.3 6.8 863 777 127 300 30.7 9.2 1129 1016 122 360 31.1 11.2 1338 1204 120 600 32.4 19.4 2138 1924 110 1000 34.3 34.3 3343 3009 97 BXRC-27H1000-D-8x 97 125 24.3 3.0 400 360 132 185 24.6 4.5 576 518 127 250 24.9 6.2 763 686 123 350 25.4 8.9 1044 939 117 500 26.1 13.0 1450 1305 111 1000 28.1 28.1 2676 2409 95 BXRC-30C1001-B-8x 70 100 32.9 3.3 664 598 202 150 33.6 5.0 970 873 193 200 34.2 6.8 1274 1147 186 270 35.0 9.5 1669 1502 176 400 36.5 14.6 2371 2134 162 500 37.5 18.7 2872 2584 153 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Table 4: Product Performance at Commonly Used Drive Currents (Continued) Performance at Commonly Used Drive Currents Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-30C1001-C-8x 70 150 29.8 4.5 900 810 201 225 30.3 6.8 1313 1182 193 300 30.7 9.2 1718 1546 186 360 31.1 11.2 2036 1832 182 600 32.4 19.4 3252 2927 167 1000 34.3 34.3 5086 4578 148 BXRC-30C1001-D-8x 70 125 24.3 3.0 609 548 201 185 24.6 4.5 876 788 193 250 24.9 6.2 1160 1044 186 350 25.4 8.9 1588 1429 179 500 26.1 13.0 2206 1986 169 1000 28.1 28.1 4072 3664 145 BXRC-30E1000-B-8x 80 100 32.9 3.3 634 571 193 150 33.6 5.0 926 834 184 200 34.2 6.8 1217 1095 178 270 35.0 9.5 1594 1435 169 400 36.5 14.6 2264 2038 155 500 37.5 18.7 2742 2468 146 BXRC-30E1000-C-8x 80 150 29.8 4.5 860 774 192 225 30.3 6.8 1254 1129 184 300 30.7 9.2 1641 1477 178 360 31.1 11.2 1944 1750 174 600 32.4 19.4 3106 2796 160 1000 34.3 34.3 4858 4372 141 BXRC-30E1000-D-8x 80 125 24.3 3.0 581 523 192 185 24.6 4.5 836 753 184 250 24.9 6.2 1108 997 178 350 25.4 8.9 1516 1365 171 500 26.1 13.0 2107 1896 162 1000 28.1 28.1 3889 3500 138 BXRC-30G1000-B-8x 90 100 32.9 3.3 515 463 157 150 33.6 5.0 752 677 149 200 34.2 6.8 988 889 144 270 35.0 9.5 1294 1165 137 400 36.5 14.6 1838 1654 126 500 37.5 18.7 2226 2004 119 BXRC-30G1000-C-8x 90 150 29.8 4.5 698 628 156 225 30.3 6.8 1018 916 149 300 30.7 9.2 1332 1199 144 360 31.1 11.2 1578 1421 141 600 32.4 19.4 2522 2269 130 1000 34.3 34.3 3943 3549 115 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-30G1000-D-8x 90 125 24.3 3.0 472 425 156 185 24.6 4.5 679 611 149 250 24.9 6.2 899 809 144 350 25.4 8.9 1231 1108 139 500 26.1 13.0 1710 1539 131 1000 28.1 28.1 3157 2841 112 BXRC-30G10H0-B-8x 90 100 32.9 3.3 539 485 164 150 33.6 5.0 787 709 156 200 34.2 6.8 1034 931 151 270 35.0 9.5 1355 1219 143 400 36.5 14.6 1925 1732 132 500 37.5 18.7 2331 2098 124 BXRC-30G10H0-C-8x 90 150 29.8 4.5 731 658 163 225 30.3 6.8 1066 960 156 300 30.7 9.2 1395 1255 151 360 31.1 11.2 1653 1487 148 600 32.4 19.4 2640 2376 136 1000 34.3 34.3 4129 3716 120 BXRC-30G10H0-D-8x 90 125 24.3 3.0 494 445 163 185 24.6 4.5 711 640 156 250 24.9 6.2 942 848 151 350 25.4 8.9 1289 1160 145 500 26.1 13.0 1791 1612 137 1000 28.1 28.1 3305 2975 118 BXRC-30H1000-B-8x 97 100 32.9 3.3 466 420 142 150 33.6 5.0 681 613 135 200 34.2 6.8 895 805 131 270 35.0 9.5 1172 1055 124 400 36.5 14.6 1665 1498 114 500 37.5 18.7 2017 1815 108 BXRC-30H1000-C-8x 97 150 29.8 4.5 632 569 141 225 30.3 6.8 922 830 135 300 30.7 9.2 1207 1086 131 360 31.1 11.2 1430 1287 128 600 32.4 19.4 2284 2056 117 1000 34.3 34.3 3572 3215 104 BXRC-30H1000-D-8x 97 125 24.3 3.0 427 385 141 185 24.6 4.5 615 554 135 250 24.9 6.2 815 733 131 350 25.4 8.9 1115 1003 126 500 26.1 13.0 1549 1394 119 1000 28.1 28.1 2859 2573 102 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-35E1000-B-8x 80 100 32.9 3.3 649 584 197 150 33.6 5.0 948 853 188 200 34.2 6.8 1246 1121 182 270 35.0 9.5 1632 1468 172 400 36.5 14.6 2318 2086 159 500 37.5 18.7 2807 2526 150 BXRC-35E1000-C-8x 80 150 29.8 4.5 880 792 197 225 30.3 6.8 1284 1156 188 300 30.7 9.2 1680 1512 182 360 31.1 11.2 1990 1791 178 600 32.4 19.4 3179 2861 164 1000 34.3 34.3 4972 4475 145 BXRC-35E1000-D-8x 80 125 24.3 3.0 595 536 196 185 24.6 4.5 856 770 188 250 24.9 6.2 1134 1021 182 350 25.4 8.9 1552 1397 175 500 26.1 13.0 2157 1941 165 1000 28.1 28.1 3980 3582 142 BXRC-35G1000-B-8x 90 100 32.9 3.3 534 480 162 150 33.6 5.0 779 701 155 200 34.2 6.8 1024 921 150 270 35.0 9.5 1341 1207 142 400 36.5 14.6 1905 1714 131 500 37.5 18.7 2307 2076 123 BXRC-35G1000-C-8x 90 150 29.8 4.5 723 651 162 225 30.3 6.8 1055 950 155 300 30.7 9.2 1380 1242 150 360 31.1 11.2 1636 1472 146 600 32.4 19.4 2613 2352 134 1000 34.3 34.3 4086 3678 119 BXRC-35G1000-D-8x 90 125 24.3 3.0 489 440 161 185 24.6 4.5 704 633 155 250 24.9 6.2 932 839 150 350 25.4 8.9 1275 1148 144 500 26.1 13.0 1772 1595 136 1000 28.1 28.1 3271 2944 116 BXRC-40C1001-B-8x 70 100 32.9 3.3 683 615 208 150 33.6 5.0 997 898 198 200 34.2 6.8 1310 1179 192 270 35.0 9.5 1716 1544 181 400 36.5 14.6 2437 2194 167 500 37.5 18.7 2952 2657 157 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-40C1001-C-8x 70 150 29.8 4.5 925 833 207 225 30.3 6.8 1350 1215 198 300 30.7 9.2 1766 1590 192 360 31.1 11.2 2093 1884 187 600 32.4 19.4 3344 3009 172 1000 34.3 34.3 5229 4706 152 BXRC-40C1001-D-8x 70 125 24.3 3.0 626 563 206 185 24.6 4.5 900 810 198 250 24.9 6.2 1193 1073 192 350 25.4 8.9 1632 1469 184 500 26.1 13.0 2268 2041 174 1000 28.1 28.1 4186 3767 149 BXRC-40E1000-B-8x 80 100 32.9 3.3 653 588 198 150 33.6 5.0 954 858 189 200 34.2 6.8 1253 1128 183 270 35.0 9.5 1641 1477 173 400 36.5 14.6 2331 2098 160 500 37.5 18.7 2823 2541 151 BXRC-40E1000-C-8x 80 150 29.8 4.5 885 796 198 225 30.3 6.8 1291 1162 189 300 30.7 9.2 1689 1520 183 360 31.1 11.2 2002 1801 179 600 32.4 19.4 3198 2878 164 1000 34.3 34.3 5001 4501 146 BXRC-40E1000-D-8x 80 125 24.3 3.0 598 539 197 185 24.6 4.5 861 775 189 250 24.9 6.2 1141 1027 183 350 25.4 8.9 1561 1405 176 500 26.1 13.0 2169 1952 166 1000 28.1 28.1 4003 3603 142 BXRC-40G1000-B-8x 90 100 32.9 3.3 545 490 166 150 33.6 5.0 796 716 158 200 34.2 6.8 1045 941 153 270 35.0 9.5 1369 1232 145 400 36.5 14.6 1945 1750 133 500 37.5 18.7 2355 2120 126 BXRC-40G1000-C-8x 90 150 29.8 4.5 738 664 165 225 30.3 6.8 1077 970 158 300 30.7 9.2 1409 1268 153 360 31.1 11.2 1670 1503 149 600 32.4 19.4 2668 2401 137 1000 34.3 34.3 4172 3755 121 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-40G1000-D-8x 90 125 24.3 3.0 499 449 165 185 24.6 4.5 718 646 158 250 24.9 6.2 952 856 153 350 25.4 8.9 1302 1172 147 500 26.1 13.0 1810 1629 139 1000 28.1 28.1 3340 3006 119 BXRC-50C1001-B-8x 70 100 32.9 3.3 687 618 209 150 33.6 5.0 1003 902 199 200 34.2 6.8 1317 1186 193 270 35.0 9.5 1725 1553 182 400 36.5 14.6 2451 2206 168 500 37.5 18.7 2968 2671 158 BXRC-50C1001-C-8x 70 150 29.8 4.5 930 837 208 225 30.3 6.8 1358 1222 199 300 30.7 9.2 1776 1599 193 360 31.1 11.2 2105 1894 188 600 32.4 19.4 3362 3026 173 1000 34.3 34.3 5258 4732 153 BXRC-50C1001-D-8x 70 125 24.3 3.0 629 566 207 185 24.6 4.5 905 815 199 250 24.9 6.2 1199 1079 193 350 25.4 8.9 1641 1477 185 500 26.1 13.0 2281 2053 175 1000 28.1 28.1 4209 3788 150 BXRC-50E1001-B-8x 80 100 32.9 3.3 661 594 201 150 33.6 5.0 965 868 192 200 34.2 6.8 1267 1140 185 270 35.0 9.5 1660 1494 175 400 36.5 14.6 2358 2122 162 500 37.5 18.7 2855 2570 152 BXRC-50E1001-C-8x 80 150 29.8 4.5 895 806 200 225 30.3 6.8 1306 1175 192 300 30.7 9.2 1709 1538 185 360 31.1 11.2 2025 1822 181 600 32.4 19.4 3234 2911 166 1000 34.3 34.3 5058 4552 147 BXRC-50E1001-D-8x 80 125 24.3 3.0 605 545 199 185 24.6 4.5 871 784 192 250 24.9 6.2 1154 1038 185 350 25.4 8.9 1579 1421 178 500 26.1 13.0 2194 1974 168 1000 28.1 28.1 4049 3644 144 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Table 3: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-50G1001-B-8x 90 100 32.9 3.3 571 514 174 150 33.6 5.0 834 750 166 200 34.2 6.8 1095 986 160 270 35.0 9.5 1435 1291 152 400 36.5 14.6 2038 1834 140 500 37.5 18.7 2468 2221 132 BXRC-50G1001-C-8x 90 150 29.8 4.5 774 696 173 225 30.3 6.8 1129 1016 166 300 30.7 9.2 1477 1329 160 360 31.1 11.2 1750 1575 156 600 32.4 19.4 2796 2516 144 1000 34.3 34.3 4372 3935 127 BXRC-50G1001-D-8x 90 125 24.3 3.0 523 471 172 185 24.6 4.5 753 677 166 250 24.9 6.2 997 897 160 350 25.4 8.9 1365 1228 154 500 26.1 13.0 1896 1707 145 1000 28.1 28.1 3500 3150 125 BXRC-57C1001-B-8x 70 100 32.9 3.3 668 601 203 150 33.6 5.0 975 878 194 200 34.2 6.8 1281 1153 187 270 35.0 9.5 1678 1511 177 400 36.5 14.6 2384 2146 163 500 37.5 18.7 2888 2599 154 BXRC-57C1001-C-8x 70 150 29.8 4.5 905 815 202 225 30.3 6.8 1321 1189 194 300 30.7 9.2 1728 1555 187 360 31.1 11.2 2047 1843 183 600 32.4 19.4 3271 2944 168 1000 34.3 34.3 5115 4604 149 BXRC-57C1001-D-8x 70 125 24.3 3.0 612 551 202 185 24.6 4.5 881 793 194 250 24.9 6.2 1167 1050 187 350 25.4 8.9 1597 1437 180 500 26.1 13.0 2219 1997 170 1000 28.1 28.1 4094 3685 146 BXRC-57E1001-B-8x 80 100 32.9 3.3 634 571 193 150 33.6 5.0 926 834 184 200 34.2 6.8 1217 1095 178 270 35.0 9.5 1594 1435 169 400 36.5 14.6 2264 2038 155 500 37.5 18.7 2742 2468 146 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Performance at Commonly Used Drive Currents Table 3: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-57E1001-C-8x 80 150 29.8 4.5 860 774 192 225 30.3 6.8 1254 1129 184 300 30.7 9.2 1641 1477 178 360 31.1 11.2 1944 1750 174 600 32.4 19.4 3106 2796 160 1000 34.3 34.3 4858 4372 141 BXRC-57E1001-D-8x 80 125 24.3 3.0 581 523 192 185 24.6 4.5 836 753 184 250 24.9 6.2 1108 997 178 350 25.4 8.9 1516 1365 171 500 26.1 13.0 2107 1896 162 1000 28.1 28.1 3889 3500 138 BXRC-65C1001-B-8x 70 100 32.9 3.3 668 601 203 150 33.6 5.0 975 878 194 200 34.2 6.8 1281 1153 187 270 35.0 9.5 1678 1511 177 400 36.5 14.6 2384 2146 163 500 37.5 18.7 2888 2599 154 BXRC-65C1001-C-8x 70 150 29.8 4.5 905 815 202 225 30.3 6.8 1321 1189 194 300 30.7 9.2 1728 1555 187 360 31.1 11.2 2047 1843 183 600 32.4 19.4 3271 2944 168 1000 34.3 34.3 5115 4604 149 BXRC-65C1001-D-8x 70 125 24.3 3.0 612 551 202 185 24.6 4.5 881 793 194 250 24.9 6.2 1167 1050 187 350 25.4 8.9 1597 1437 180 500 26.1 13.0 2219 1997 170 1000 28.1 28.1 4094 3685 146 BXRC-65E1001-B-8x 80 100 32.9 3.3 642 578 195 150 33.6 5.0 937 844 186 200 34.2 6.8 1231 1108 180 270 35.0 9.5 1613 1452 171 400 36.5 14.6 2291 2062 157 500 37.5 18.7 2775 2497 148 BXRC-65E1001-C-8x 80 150 29.8 4.5 870 783 194 225 30.3 6.8 1269 1142 186 300 30.7 9.2 1660 1494 180 360 31.1 11.2 1967 1771 176 600 32.4 19.4 3143 2829 162 1000 34.3 34.3 4915 4424 143 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-65E1001-D-8x 80 125 24.3 3.0 588 529 194 185 24.6 4.5 846 762 186 250 24.9 6.2 1121 1009 180 350 25.4 8.9 1534 1381 173 500 26.1 13.0 2132 1919 164 1000 28.1 28.1 3934 3541 140 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Electrical Characteristics
Table 5: Electrical Characteristics Part Number Drive Current (mA) Forward Voltage Pulsed, Tc = 25ºC (V) 1, 2, 3, 8 Typical Coefficient of Forward Voltage4 ∆Vf/∆Tc (mV/ºC) Typical Thermal Resistance Junction to Case5,6 Rj-c (ºC/W) Driver Selection Voltages7 (V) Minimum Typical Maximum Vf Min. Hot Tc = 105ºC (V) Vf Max. Cold Tc = -40ºC (V) BXRC-xxx100x-B-8x BXRC-xxx100x-C-8x BXRC-xxx100x-D-8x Notes for Table 5: 1. Parts are tested in pulsed conditions, Tc = 25°C. Pulse width is 10ms. 2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance. 3. Bridgelux maintains a tester tolerance of ± 0.10V on forward voltage measurements. 4. Typical coefficient of forward voltage tolerance is ± 0.1mV for nominal current. 5. Thermal resistance values are based from test data of a 3000K 80 CRI product. 6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal interface material used during testing is not included in the thermal resistance value. 7. Vf min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design and selection over the operating range of the product. 8. This product has been designed and manufactured per IEC 62031:2018. This product has passed dielectric withstand voltage testing at 1140 V. The work- ing voltage designated for the insulation is 70V d.c. The maximum allowable voltage across the array must be determined in the end product application.
Table 6: Eye Safety Risk Group (RG) Classifications Part Number Drive Current (mA) CCT5 2700K/3000K 4000K2 5000K3 6500K4 BXRC-xxx100x-B-8x
355 RG1 RG1 RG1 RG1
500 RG1 RG1 RG1 RG2
395 RG1 RG1 RG1 RG1
550 RG1 RG1 RG1 RG2
730 RG1 RG1 RG2 RG2
1000 RG1 RG2 RG2 RG2
490 RG1 RG1 RG1 RG1
680 RG1 RG1 RG1 RG2
900 RG1 RG1 RG2 RG2
Notes for Table 6: 1. Eye safety classification for the use of Bridgelux Vero Series LED arrays is in accordance with specification IEC/TR 62778: Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires. 2. For products classified as RG2 at 4000K, Ethr= 1980 lx. 3. For products classified as RG2 at 5000K Ethr= 1530 lx. 4. For products classified as RG2 at 6500K, Ethr= 1170 lx. 5. Please contact your Bridgelux sales representative for Ethr values at specific drive currents and CCTs not listed.
LED Junction Temperature (Tj) 150°C Storage Temperature -40°C to +105°C Operating Case Temperature1 (Tc) 105°C Soldering Temperature2 300°C or lower for a maximum of 6 seconds BXRC-xxx100x-B-8x BXRC-xxx100x-C-8x BXRC-xxx100x-D-8x Maximum Drive Current3 500 mA 1000 mA 1000 mA Maximum Peak Pulsed Drive Current4 560 mA 1120 mA 1120 mA Maximum Reverse Voltage5 -60V -55V -45V Notes for Table 7: 1. For IEC 62717 requirement, please consult your Bridgelux sales representative. 2. Refer to Bridgelux Application Note AN31: Assembly Considerations for Bridgelux Vero LED Arrays. 3. Arrays may be driven at higher currents however lumen maintenance may be reduced and warranty will not apply. 4. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed current specified. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures. 5. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating provided for reference only. Table 7: Maximum Ratings
Figure 12: Typical Color Spectrum Notes for Figure 12: 1. Color spectra measured at nominal current for Tj = Tc = 25°C. 2. Color spectra shown is 3000K and 80 CRI. 3. Color spectra shown is 4000K and 80 CRI. 4. Color spectra shown is 5000K and 70 CRI. 4. Color spectra shown is 6500K and 70 CRI. 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 110% 400 450 500 550 600 650 700 750 800 Relative Spectral Power Distribution Wavelength (nm) 3000K 4000K 5000K 6500K
Figure 13: Drawing for Vero 10 LED Array Notes for Figure 13: 1. Drawings are not to scale. 2. Dimensions are in mm. 3. Unless otherwise specified, tolerances are ± 0.10mm. 4. Mounting slots (2X) are for M2.5 screws. 5. Bridgelux recommends two tapped holes for mounting screws with 19.0 ± 0.10mm center-to-center spacing. 6. Screws with flat shoulders (pan, dome, button, round, truss, mushroom) provide optimal torque control. Do NOT use flat, countersink, or raised head screws. 7. Solder pads and connector port are labeled “+” and “-“ to denote positive and negative, respectively. 8. It is not necessary to provide electrical connections to both the solder pads and the connector port. Either set may be used depending on application specific design requirements. 9. Refer to Application Notes AN30 and AN31 for product handling, mounting and heat sink recommendations. 10. The optical center of the LED Array is nominally defined by the mechanical center of the array to a tolerance of ± 0.2mm. 11. Bridgelux maintains a flatness of 0.10mm across the mounting surface of the array.
Figure 14: Warm and Neutral White Test Bins in xy Color Space Color Binning Information Bin Code 2700K 3000K 3500K 4000K ANSI Bin (for reference only) (2580K - 2870K) (2870K - 3220K) (3220K - 3710K) (3710K - 4260K) 83 (3 SDCM) (2651K - 2794K) (2968K - 3136K) (3369K - 3586K) (3851K - 4130K) 82 (2 SDCM) (2674K - 2769K) (2995K - 3107K) (3404K - 3548K) (3895K - 4081K) Table 8: Warm and Neutral White xy Bin Coordinates and Associated Typical CCT Bin Code 5000K 5700K 6500K ANSI Bin (for reference only) (4745K - 5311K) (5312K - 6022K) (6022K - 7042K) 84 (4 SDCM) (4801K - 5282K) (5395K- 5970K) (6200K - 6910K) 83 (3 SDCM) (4835K-5215K) (5460K- 5891K) (6279K -6811K) Table 9: Cool White xy Bin Coordinates and Associated Typical CCT (product is hot targeted to Tc = 85°C) Note: Pulsed Test Conditions, Tc = 25°C Figure 15: Graph of Cool White Test Bins in xy Color Space Note: Pulsed Test Conditions, Tc = 25°C 0.3 0.31 0.32 0.33 0.34 0.35 0.36 0.37 0.38 0.39 Y X
4 SDCM
3 SDCM
Note for Tables 8-9: 1. Bridgelux maintains a tolerance of +/- 0.007 on x and y color coordinates in the CIE 1931 color Space.
Figure 16: Drawing for Vero 10 Packaging Tray Notes for Figure 16: 1. Dimensions are in millimeters. 2. Drawings are not to scale.
Bridgelux has developed a comprehensive set of application notes and design resources to assist customers in successfully designing with the Vero product family of LED array products. For all available application notes visit www.bridgelux.com. Optical Source Models Optical source models and ray set files are available for all Bridgelux products. For a list of available formats, visit www.bridgelux.com. MINOR PRODUCT CHANGE POLICY The rigorous qualification testing on products offered by Bridgelux provides performance assurance. Slight cosmetic changes that do not affect form, fit, or function may occur as Bridgelux continues product optimization. CAUTION: CHEMICAL EXPOSURE HAZARD Exposure to some chemicals commonly used in luminaire manufacturing and assembly can cause damage to the LED array. Please consult Bridgelux CAUTION: RISK OF BURN Do not touch the Vero LED array during operation. Allow the array to cool for a sufficient period of time before handling. The Vero LED array may reach elevated temperatures such that could burn skin when touched. 3D CAD Models Three dimensional CAD models depicting the product outline of all Bridgelux Vero LED arrays are available in both IGS and STEP formats. Please contact your Bridgelux sales representative for assistance. LM80 LM80 testing has been completed and the LM80 report is now available. Please contact your Bridgelux sales rep- resentative for LM-80 report. CAUTION CONTACT WITH LIGHT EMITTING SURFACE (LES) Avoid any contact with the LES. Do not touch the LES of the LED array or apply stress to the LES (yellow phosphor resin area). Contact may cause damage to the LED array. Optics and reflectors must not be mounted in contact with the LES (yellow phosphor resin area). Optical devices may be mounted on the top surface of the plastic housing of the Vero LED array. Use the mechanical features of the LED array housing, edges and/or mounting holes to locate and secure optical devices as needed. STANDARD TEST CONDITIONS Unless otherwise stated, array testing is performed at the nominal drive current.
About Bridgelux: Bridging Light and Life™ © 2023 Bridgelux, Inc. All rights reserved. Product specifications are subject to change without notice. Bridgelux, the Bridgelux stylized logo design, Vero, V Series and V Series HD are registered trademarks, and Decor Series is a trademark of Bridgelux, Inc. All other trademarks are the property of their respective owners. Bridgelux Gen 8 Vero 10 Array Series Product Data Sheet DS420 Rev. D (08/2023)
46410 Fremont Boulevard
Fremont, CA 94538 U.S.A. Tel (925) 583-8400 www.bridgelux.com At Bridgelux, we help companies, industries and people experience the power and possibility of light. Since 2002, we’ve designed LED solutions that are high performing, energy efficient, cost effective and easy to integrate. Our focus is on light’s impact on human behavior, delivering products that create better environments, experiences and returns—both experiential and financial. And our patented technology drives new platforms for commercial and industrial luminaires. For more information about the company, please visit bridgelux.com twitter.com/Bridgelux facebook.com/Bridgelux youtube.com/user/Bridgelux linkedin.com/company/bridgelux-inc-_2 WeChat ID: BridgeluxInChina