The V Series™ LED Array products deliver high quality light in a compact and cost-effective solid-state lighting package. These chip on board (CoB) arrays can be efficiently driven up to three times the nominal drive current, enabling design flexibility not previously possible. These high flux density light sources are designed to support a wide range of high quality, low cost directional luminaires and replacement lamps for both interior and exterior commercial and residential applications. The V15 LED Array is available in a variety of electrical, CCT, and CRI combinations providing substantial design flexibility and energy efficiency advantages. Lighting system designs incorporating these LED arrays deliver increased system level efficacy and a longer service life. Typical applications include replacement lamps and task, accent, spot, track, wide area, security, wall packs and down lights. V Series

Features

  • Efficacy of 178 lm/W typical, 3000K 80 CRI
  • Reliable operation at up to 3x nominal current, 30% increase in maximum lumens per LES size
  • Wide selection of CCT options (2700K-6500K) with minimum 70, 80 and 90 CRI options
  • Uniform high-quality illumination
  • 2 and 3 SDCM binning options (2700K – 4000K)
  • Forward voltage bin codes and backside marking
  • Instant light with unlimited dimming
  • 5-Year warranty Benefits
  • Enables high efficiency lighting systems and lower operating costs
  • Supports the trend toward luminaire miniaturization and delivers enhanced optical control
  • Design flexibility for a broad range of lighting

applications

  • Clean white light without pixelation
  • Uniform consistent white light
  • Design flexibility for multi-source applications
  • Easy to use with daylight and motion sensors to increase energy savings
  • Design with confidence

The part number designation for Bridgelux V Series LED arrays is explained as follows: 1 2 3 4 5 6 7 8 9 10 11 – 12 – 13 14 Product Family CCT Bin Options 2 = 2 SDCM 3 = 3 SDCM 4 = 4 SDCM CRI C = 70 CRI min. E = 80 CRI min. G = 90 CRI min. H = 97 CRI typ. Array Configuration 27 = 2,700K 30 = 3,000K 35 = 3,500K 40 = 4,000K 50 = 5,000K 57 = 5,700K 65 = 6,500K BXRE – 30 E 300 0 – D – 8 3 Color Targeting Designator 0 = Cold Targeted 1 = Hot Targeted C = Décor Series Showcase Target Gen. 8Nominal CCT Flux Indicator 300x = 3000 lm Bridgelux arrays are fully engineered devices that provide consistent thermal and optical performance on an engineered mechanical platform. The V Series arrays are the most compact chip-on-board devices across all of Bridgelux’s LED Array products. The arrays incorporate several features to simplify design integration and assembly. Please visit www.bridgelux.com for more information on the V Series family of products. Fully engineered substrate for consistent thermal, mechanical and optical properties Yellow phosphor Light Emitting Surface (LES) Note: Part number and lot codes are scribed on back of array Polarity symbols Solder Pads White ring around LES Case Temperature (Tc) Measurement Point Designed to comply with global safety standards for creepage and clearance distances

The following product configurations are available: Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRE-27E3000-D-8x 2700 80 500 2827 2545 33.7 16.9 168 BXRE-27G3000-D-8x 2700 90 500 2333 2099 33.7 16.9 138 BXRE-27G30H0-D-8x 2700 90 500 2433 2190 33.7 16.9 144 BXRE-27H3000-D-8x 2700 97 500 2067 1861 33.7 16.9 123 BXRE-30C3001-D-8x 3000 70 500 3145 2831 33.7 16.9 187 BXRE-30E3000-D-8x 3000 80 500 3004 2704 33.7 16.9 178 BXRE-30G3000-D-8x 3000 90 500 2439 2195 33.7 16.9 145 BXRE-30G30H0-D-8x 3000 90 500 2553 2298 33.7 16.9 152 BXRE-30H3000-D-8x 3000 97 500 2209 1988 33.7 16.9 131 BXRE-35E3000-D-8x 3500 80 500 3075 2767 33.7 16.9 182 BXRE-35G3000-D-8x 3500 90 500 2527 2274 33.7 16.9 150 BXRE-40C3001-D-8x 4000 70 500 3234 2910 33.7 16.9 192 BXRE-40E3000-D-8x 4000 80 500 3092 2783 33.7 16.9 184 BXRE-40G3000-D-8x 4000 90 500 2580 2322 33.7 16.9 153 BXRE-50C3001-D-8x 5000 70 500 3251 2926 33.7 16.9 193 BXRE-50E3001-D-8x 5000 80 500 3128 2815 33.7 16.9 186 BXRE-50G3001-D-8x 5000 90 500 2704 2433 33.7 16.9 160 BXRE-57C3001-D-8x 5700 70 500 3163 2847 33.7 16.9 188 BXRE-57E3001-D-8x 5700 80 500 3004 2704 33.7 16.9 178 BXRE-65C3001-D-8x 6500 70 500 3163 2847 33.7 16.9 188 BXRE-65E3001-D-8x 6500 80 500 3039 2735 33.7 16.9 180 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Décor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, Minimum R9 value is 60 for 90 CRI products on 2700K/3000K/3500K and 4000K, it is 50 on 5000K/5700K and 6500K. But for the CRI90 H0 products (higher efficiency CRI90 version), minimum R9 value is 55 on 2700K/3000K/3500K and 4000K. Minimum R9 value for 97 CRI products is 93 on 2700K and 3000K,and it is 85 on 3500K /4000K/5000K and 5700K. Bridgelux maintains a ± 3 tolerance on R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal drive current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test.

Table 2: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRE-27E3000-D-8x 2700 80 500 2545 2290 33.0 16.5 154 BXRE-27G3000-D-8x 2700 90 500 2099 1889 33.0 16.5 127 BXRE-27G30H0-D-8x 2700 90 500 2190 1971 33.0 16.5 133 BXRE-27H3000-D-8x 2700 97 500 1861 1675 33.0 16.5 113 BXRE-30C3001-D-8x 3000 70 500 2831 2548 33.0 16.5 171 BXRE-30E3000-D-8x 3000 80 500 2704 2433 33.0 16.5 164 BXRE-30G3000-D-8x 3000 90 500 2195 1975 33.0 16.5 133 BXRE-30G30H0-D-8x 3000 90 500 2298 2068 33.0 16.5 139 BXRE-30H3000-D-8x 3000 97 500 1988 1789 33.0 16.5 120 BXRE-35E3000-D-8x 3500 80 500 2767 2490 33.0 16.5 168 BXRE-35G3000-D-8x 3500 90 500 2274 2047 33.0 16.5 138 BXRE-40C3001-D-8x 4000 70 500 2910 2619 33.0 16.5 176 BXRE-40E3000-D-8x 4000 80 500 2783 2505 33.0 16.5 169 BXRE-40G3000-D-8x 4000 90 500 2322 2090 33.0 16.5 141 BXRE-50C3001-D-8x 5000 70 500 2926 2634 33.0 16.5 177 BXRE-50E3001-D-8x 5000 80 500 2815 2533 33.0 16.5 170 BXRE-50G3001-D-8x 5000 90 500 2433 2190 33.0 16.5 147 BXRE-57C3001-D-8x 5700 70 500 2847 2562 33.0 16.5 172 BXRE-57E3001-D-8x 5700 80 500 2704 2433 33.0 16.5 164 BXRE-65C3001-D-8x 6500 70 500 2847 2562 33.0 16.5 172 BXRE-65E3001-D-8x 6500 80 500 2735 2462 33.0 16.5 166 Notes for Table 2: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Décor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, Minimum R9 value is 60 for 90 CRI products on 2700K/3000K/3500K and 4000K, it is 50 on 5000K/5700K and 6500K. But for the CRI90 H0 products (higher efficiency CRI90 version), minimum R9 value is 55 on 2700K/3000K/3500K and 4000K. Minimum R9 value for 97 CRI products is 93 on 2700K and 3000K,and it is 85 on 3500K /4000K/5000K and 5700K. Bridgelux maintains a ± 3 tolerance on R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.

European Product Registry for Energy Labeling The European Product Registry for Energy Labeling (EPREL) is defined in the EU Regulation 2017/1369 to provide import- ant energy efficiency information to consumers. Together with Energy Labeling Regulation ELR (EU) 2019/2015 which was amended by regulation (EU) 2021/340 for energy labelling of light sources, manufacturers are required to declare an ener- gy class based on key technical specifications from each of their product and register it in an open data base managed by EPREL It is now a legal requirement for a vendor of light sources to upload information about their products into the EPREL database before placing these products on the market in the EU. Table 3 below provides a list of part numbers that are in compliance with ELR and are currently listed in the EPREL data- base. At Bridgelux, we are fully committed to supplying products that are compliant with pertinent laws, rules, and obligation imposed by relevant government bodies including the European Energy Labeling regulation. Customers can use these products with full confidence for any projects that fall under the ELR. Table 3: Part numbers registered in European Product Registry for Energy Labeling PART NUMBER1 CCT (K) CRI Current2 (mA) Vf (V) Useful flux3 (Φuse) at 85C (lm) Pow- er (W) Efficacy (lm/W) Energy efficiency class4 Regis- tration No URL to Product Information Sheet in EPREL Database Notes for Table 3: 1. All device listed here must be disposed as e-waste upon its end of life according to local country guideline in each country. 2. For information on performance values at alternative drive conditions. please refer to the Product Selection Guide, Absolute Maximum Rating Table and Performance Curves in this data sheet. 3. For a definition of useful luminous flux (ΦΦuse), please see the ELR regulations at https:/ /tinyurl.com/4b6zvt4m. 4. EPREL requires an arrow symbol containing the letter of the energy efficiency class to be displayed. on technical promotional material. Refer to this energy efficiency class column for specific energy efficiency class on each part number.

Performance at Commonly Used Drive Currents V Series LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. V Series may also be driven at other drive currents dependent on specific application design requirements. The performance at any drive current can be derived from the current vs. voltage characteristics shown in Figure 1 and the flux vs. current characteristics shown in Figure 2. The performance at commonly used drive currents is summarized in Table 4. Table 4: Product Performance at Commonly Used Drive Currents Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRE-27E3000-D-8x 80 250 32.6 8.2 1459 1313 179 375 33.2 12.4 2154 1938 173 500 33.7 16.9 2827 2545 168 700 34.6 24.2 3888 3499 161 1000 35.8 35.8 5396 4856 151 1500 37.6 56.4 7710 6939 137 BXRE-27G3000-D-8x 90 250 32.6 8.2 1204 1083 148 375 33.2 12.4 1777 1599 143 500 33.7 16.9 2333 2099 138 700 34.6 24.2 3207 2887 132 1000 35.8 35.8 4451 4006 124 1500 37.6 56.4 6361 5725 113 BXRE-27G30H0-D-8x 90 250 32.6 8.2 1256 1130 154 375 33.2 12.4 1854 1668 149 500 33.7 16.9 2433 2190 144 700 34.6 24.2 3346 3011 138 1000 35.8 35.8 4644 4179 130 1500 37.6 56.4 6636 5972 118 BXRE-27H3000-D-8x 97 250 32.6 8.2 1067 960 131 375 33.2 12.4 1575 1418 127 500 33.7 16.9 2067 1861 123 700 34.6 24.2 2843 2559 117 1000 35.8 35.8 3945 3551 110 1500 37.6 56.4 5638 5074 100 BXRE-30C3001-D-8x 70 250 32.6 8.2 1623 1461 199 375 33.2 12.4 2396 2157 193 500 33.7 16.9 3145 2831 186 700 34.6 24.2 4325 3893 179 1000 35.8 35.8 6003 5402 168 1500 37.6 56.4 8578 7720 152 BXRE-30E3000-D-8x 80 250 32.6 8.2 1550 1395 190 375 33.2 12.4 2288 2060 184 500 33.7 16.9 3004 2704 178 700 34.6 24.2 4131 3718 171 1000 35.8 35.8 5733 5159 160 1500 37.6 56.4 8192 7373 145 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRE-30G3000-D-8x 90 250 32.6 8.2 1259 1133 154 375 33.2 12.4 1858 1672 149 500 33.7 16.9 2439 2195 145 700 34.6 24.2 3353 3018 138 1000 35.8 35.8 4654 4188 130 1500 37.6 56.4 6650 5985 118 BXRE-30G30H0-D-8x 90 250 32.6 8.2 1318 1186 162 375 33.2 12.4 1945 1751 156 500 33.7 16.9 2553 2298 151 700 34.6 24.2 3511 3160 145 1000 35.8 35.8 4873 4386 136 1500 37.6 56.4 6963 6267 123 BXRE-30H3000-D-8x 97 250 32.6 8.2 1140 1026 140 375 33.2 12.4 1683 1514 135 500 33.7 16.9 2209 1988 131 700 34.6 24.2 3037 2734 125 1000 35.8 35.8 4215 3794 118 1500 37.6 56.4 6024 5421 107 BXRE-35E3000-D-8x 80 250 32.6 8.2 1587 1428 195 375 33.2 12.4 2342 2108 188 500 33.7 16.9 3075 2767 182 700 34.6 24.2 4228 3805 175 1000 35.8 35.8 5868 5281 164 1500 37.6 56.4 8385 7547 149 BXRE-35G3000-D-8x 90 250 32.6 8.2 1304 1174 160 375 33.2 12.4 1925 1733 155 500 33.7 16.9 2527 2274 150 700 34.6 24.2 3475 3127 143 1000 35.8 35.8 4822 4340 135 1500 37.6 56.4 6891 6202 122 BXRE-40C3001-D-8x 70 250 32.6 8.2 1669 1502 205 375 33.2 12.4 2463 2217 198 500 33.7 16.9 3234 2910 192 700 34.6 24.2 4447 4002 184 1000 35.8 35.8 6171 5554 172 1500 37.6 56.4 8819 7937 156 BXRE-40E3000-D-8x 80 250 32.6 8.2 1596 1436 196 375 33.2 12.4 2356 2120 189 500 33.7 16.9 3092 2783 183 700 34.6 24.2 4252 3827 176 1000 35.8 35.8 5901 5311 165 1500 37.6 56.4 8433 7590 150 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Table 4: Product Performance at Commonly Used Drive Currents (Continued) Performance at Commonly Used Drive Currents Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRE-40G3000-D-8x 90 250 32.6 8.2 1331 1198 163 375 33.2 12.4 1965 1769 158 500 33.7 16.9 2580 2322 153 700 34.6 24.2 3548 3193 146 1000 35.8 35.8 4923 4431 138 1500 37.6 56.4 7036 6332 125 BXRE-50C3001-D-8x 70 250 32.6 8.2 1678 1510 206 375 33.2 12.4 2477 2229 199 500 33.7 16.9 3251 2926 193 700 34.6 24.2 4471 4024 185 1000 35.8 35.8 6205 5584 173 1500 37.6 56.4 8867 7980 157 BXRE-50E3001-D-8x 80 250 32.6 8.2 1614 1453 198 375 33.2 12.4 2383 2144 191 500 33.7 16.9 3128 2815 185 700 34.6 24.2 4301 3871 178 1000 35.8 35.8 5969 5372 167 1500 37.6 56.4 8530 7677 151 BXRE-50G3001-D-8x 90 250 32.6 8.2 1395 1256 171 375 33.2 12.4 2060 1854 165 500 33.7 16.9 2704 2433 160 700 34.6 24.2 3718 3346 153 1000 35.8 35.8 5159 4644 144 1500 37.6 56.4 7373 6636 131 BXRE-57C3001-D-8x 70 250 32.6 8.2 1632 1469 200 375 33.2 12.4 2410 2169 194 500 33.7 16.9 3163 2847 187 700 34.6 24.2 4349 3915 180 1000 35.8 35.8 6036 5433 169 1500 37.6 56.4 8626 7763 153 BXRE-57E3001-D-8x 80 250 32.6 8.2 1550 1395 190 375 33.2 12.4 2288 2060 184 500 33.7 16.9 3004 2704 178 700 34.6 24.2 4131 3718 171 1000 35.8 35.8 5733 5159 160 1500 37.6 56.4 8192 7373 145 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Table 4: Product Performance at Commonly Used Drive Currents (Continued) Performance at Commonly Used Drive Currents Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRE-65C3001-D-8x 70 250 32.6 8.2 1632 1469 200 375 33.2 12.4 2410 2169 194 500 33.7 16.9 3163 2847 187 700 34.6 24.2 4349 3915 180 1000 35.8 35.8 6036 5433 169 1500 37.6 56.4 8626 7763 153 BXRE-65E3001-D-8x 80 250 32.6 8.2 1569 1412 192 375 33.2 12.4 2315 2084 186 500 33.7 16.9 3039 2735 180 700 34.6 24.2 4179 3761 173 1000 35.8 35.8 5800 5220 162 1500 37.6 56.4 8289 7460 147 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Electrical Characteristics

Table 5: Electrical Characteristics Part Number Drive Current (mA) Forward Voltage Pulsed, Tc = 25ºC (V) 1, 2, 3, 8 Typical Coefficient of Forward Voltage4 ∆Vf/∆Tc (mV/ºC) Typical Thermal Resistance Junction to Case5,6 Rj-c (ºC/W) Driver Selection Voltages7 (V) Minimum Typical Maximum Vf Min. Hot Tc = 105ºC (V) Vf Max. Cold Tc = -40ºC (V) BXRE-xxx300x-D-8x Notes for Table 5: 1. Parts are tested in pulsed conditions, Tc = 25°C. Pulse width is 10ms. 2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance. 3. Bridgelux maintains a tester tolerance of ± 0.10V on forward voltage measurements. 4. Typical coefficient of forward voltage tolerance is ± 0.1mV for nominal current. 5. Thermal resistance values are based from test data of a 3000K 80 CRI product. 6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal interface material used during testing is not included in the thermal resistance value. 7. Vf min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design and selection over the operating range of the product. 8. This product has been designed and manufactured per IEC 62031:2018. This product has passed dielectric withstand voltage testing at 1140 V. The work- ing voltage designated for the insulation is 70V d.c. The maximum allowable voltage across the array must be determined in the end product application.

Table 6: Eye Safety Risk Group (RG) Classifications Part Number Drive Current (mA) CCT4 2700K/3000K 4000K 5000K2 6500K3 BXRE-xxx300x-D-8x

885 RG1 RG1 RG1 RG1

1225 RG1 RG1 RG1 RG2

1500 RG1 RG1 RG2 RG2

Notes for Table 6: 1. Eye safety classification for the use of Bridgelux V Series LED arrays is in accordance with specification IEC/TR 62778: Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires. 2. For products classified as RG2 at 5000K Ethr= 1530 lx. 3. For products classified as RG2 at 6500K, Ethr= 1170 lx. 4. Please contact your Bridgelux sales representative for Ethr values at specific drive currents and CCTs not listed.

LED Junction Temperature (Tj) 150°C Storage Temperature -40°C to +105°C Operating Case Temperature1 (Tc) 105°C Soldering Temperature2 300°C or lower for a maximum of 6 seconds Maximum Drive Current3 1500 mA Maximum Peak Pulsed Drive Current4 1680mA Maximum Reverse Voltage5 -60V Notes for Table 7: 1. For IEC 62717 requirement, please consult your Bridgelux sales representative. 2. Refer to Bridgelux Application Note AN101: Handling and Assembly of Bridgelux V Series LED Arrays 3. Arrays may be driven at higher currents however lumen maintenance may be reduced and warranty will not apply. 4. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed current specified. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures. 5. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating provided for reference only. Table 7: Maximum Ratings

Figure 8: Typical Color Spectrum Notes for Figure 8: 1. Color spectra measured at nominal current for Tj = Tc = 25°C. 2. Color spectra shown is 3000K and 80 CRI. 3. Color spectra shown is 4000K and 80 CRI. 4. Color spectra shown is 5000K and 70 CRI. 4. Color spectra shown is 6500K and 70 CRI. 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 110% 400 450 500 550 600 650 700 750 800 Relative Spectral Power Distribution Wavelength (nm) 3000K 4000K 5000K 6500K

Figure 9: Drawing for V15 LED Array Notes for Figure 9; 1. Drawings are not to scale. 2. Drawing dimensions are in millimeters. 3. Unless otherwise specified, tolerances are ±0.1mm. 4. Solder pad labeled “+” denotes positive contact. 5. Refer to Application Notes AN101 for product handling, mounting and heat sink recommendations. 6. The optical center of the LED Array is nominally defined by the mechanical center of the array to a tolerance of ± 0.2mm. 7. Bridgelux maintains a flatness of 0.10mm across the mounting surface of the array.

Bin Code 2700K 3000K 3500K 4000K ANSI Bin (for reference only) (2580K - 2870K) (2870K - 3220K) (3220K - 3710K) (3710K - 4260K) 83 (3 SDCM) (2651K - 2794K) (2968K - 3136K) (3369K - 3586K) (3851K - 4130K) 82 (2 SDCM) (2674K - 2769K) (2995K - 3107K) (3404K - 3548K) (3895K - 4081K) Table 8: Warm and Neutral White xy Bin Coordinates and Associated Typical CCT Bin Code 5000K 5700K 6500K ANSI Bin (for reference only) (4745K - 5311K) (5312K - 6022K) (6022K - 7042K) 84 (4 SDCM) (4801K - 5282K) (5395K- 5970K) (6200K - 6910K) 83 (3 SDCM) (4835K - 5215K) (5460K- 5891K) (6279K -6811K) Table 9: Cool White xy Bin Coordinates and Associated Typical CCT (product is hot targeted to Tc = 85°C) Figure 10: Warm and Neutral White Test Bins in xy Color Space Note: Pulsed Test Conditions, Tc = 25°C Figure 11: Cool White Test Bins in xy Color Space Note: Pulsed Test Conditions, Tc = 25°C 0.3 0.31 0.32 0.33 0.34 0.35 0.36 0.37 0.38 0.39 Y X

4 SDCM

3 SDCM

Note for Tables 8-9: 1. Bridgelux maintains a tolerance of +/- 0.007 on x and y color coordinates in the CIE 1931 color Space.

Figure 12: Drawing for V15 Packaging Tube Notes for Figure 12: 1. Each tube holds 25 V15 COB arrays. 2. One tube is sealed in an anti-static bag. Four bags are placed in a shipping box. Depending on quantities ordered, a bigger shipping box, containing four boxes may be used to ship products. 3. Each bag and box is to be labeled as shown above. the shipping box are 58.7 x 13.3 x 7.9 cm

Figure 13: Gen. 8 Product Labeling Bridgelux COB arrays have laser markings on the back side of the substrate to help with product identification. In addition to the product identification markings, Bridgelux COB arrays also contain markings for internal Bridgelux manufacturing use only. The image below shows which markings are for customer use and which ones are for Bridgelux internal use only. The Bridgelux internal manufacturing markings are subject to change without notice, however these will not impact the form, function or performance of the COB array. Customer Use- 2D Barcode Scannable barcode provides product part number and other Bridgelux internal production information. Customer Use- Product part number Customer Use- Vf Bin Code included to enable greater luminaire design flexibility. Refer to AN92 for bin code definitions. 30E3000D 81 2F Internal Bin Code

Bridgelux has developed a comprehensive set of application notes and design resources to assist customers in successfully designing with the V Series product family of LED array products. For all available application notes visit www.bridgelux.com. Optical Source Models Optical source models and ray set files are available for all Bridgelux products. For a list of available formats, visit www.bridgelux.com. MINOR PRODUCT CHANGE POLICY The rigorous qualification testing on products offered by Bridgelux provides performance assurance. Slight cosmetic changes that do not affect form, fit, or function may occur as Bridgelux continues product optimization. CAUTION: CHEMICAL EXPOSURE HAZARD Exposure to some chemicals commonly used in luminaire manufacturing and assembly can cause damage to the LED array. Please consult Bridgelux CAUTION: RISK OF BURN Do not touch the V Series LED array during operation. Allow the array to cool for a sufficient period of time before handling. The V Series LED array may reach elevated temperatures such that could burn skin when touched. 3D CAD Models Three dimensional CAD models depicting the product outline of all Bridgelux V Series LED arrays are available in both IGS and STEP formats. Please contact your Bridgelux sales representative for assistance. LM80 LM80 testing has been completed and the LM80 report is now available. Please contact your Bridgelux sales representative for LM-80 report. STANDARD TEST CONDITIONS Unless otherwise stated, array testing is performed at the nominal drive current. CAUTION CONTACT WITH LIGHT EMITTING SURFACE (LES) Avoid any contact with the LES. Do not touch the LES of the LED array or apply stress to the LES (yellow phosphor resin area). Contact may cause damage to the LED array. Optics and reflectors must not be mounted in contact with the LES (yellow phosphor resin area).

About Bridgelux: Bridging Light and Life™ © 2021 Bridgelux, Inc. All rights reserved. Product specifications are subject to change without notice. Bridgelux, the Bridgelux stylized logo design and Vero are registered trademarks, V Series and Decor Series are trademarks of Bridgelux, Inc. All other trademarks are the property of their respective owners. Bridgelux Gen 8 V15 Array Series Product Data Sheet DS414 Rev. D (11/2022)

46410 Fremont Boulevard

Fremont, CA 94538 U.S.A. Tel (925) 583-8400 www.bridgelux.com At Bridgelux, we help companies, industries and people experience the power and possibility of light. Since 2002, we’ve designed LED solutions that are high performing, energy efficient, cost effective and easy to integrate. Our focus is on light’s impact on human behavior, deliver- ing products that create better environments, experiences and returns—both experiential and financial. And our patented technology drives new platforms for commercial and industrial luminaires. For more information about the company, please visit bridgelux.com twitter.com/Bridgelux facebook.com/Bridgelux youtube.com/user/Bridgelux linkedin.com/company/bridgelux-inc-_2 WeChat ID: BridgeluxInChina