The V Series™ LED Array products deliver high quality light in a compact and cost-effective solid-state lighting package. These chip on board (CoB) arrays can be efficiently driven up to three times the nominal drive current, enabling design flexibility not previously possible. These high flux density light sources are designed to support a wide range of high quality, low cost directional luminaires and replacement lamps for both interior and exterior commercial and residential applications. The V13 LED Array is available in a variety of electrical, CCT, and CRI combinations providing substantial design flexibility and energy efficiency advantages. Lighting system designs incorporating these LED arrays deliver increased system level efficacy and a longer service life. Typical applications include replacement lamps and task, accent, spot, track, wide area, security, wall packs and down lights. V Series

Features

  • Efficacy of 178 lm/W typical, 3000K 80 CRI
  • Reliable operation at up to 3x nominal current, 30% increase in maximum lumens per LES size
  • Wide selection of CCT options (2200K-6500K) with minimum 70, 80 and 90 CRI options
  • Uniform high-quality illumination
  • 2 and 3 SDCM binning options (2700K – 4000K)
  • Forward voltage bin codes and backside marking
  • Instant light with unlimited dimming
  • 5-Year warranty Benefits
  • Enables high efficiency lighting systems and lower operating costs
  • Supports the trend toward luminaire miniaturization and delivers enhanced optical control
  • Design flexibility for a broad range of lighting

applications

  • Clean white light without pixelation
  • Uniform consistent white light
  • Design flexibility for multi-source applications
  • Easy to use with daylight and motion sensors to increase energy savings
  • Design with confidence

The part number designation for Bridgelux V Series LED arrays is explained as follows: 1 2 3 4 5 6 7 8 9 10 11 – 12 – 13 14 Product Family CCT Bin Options 2 = 2 SDCM 3 = 3 SDCM 4 = 4 SDCM CRI C = 70 CRI min. E = 80 CRI min. G = 90 CRI min. H = 97 CRI typ. Array Configuration 27 = 2,700K 30 = 3,000K 35 = 3,500K 40 = 4,000K 50 = 5,000K 57 = 5,700K 65 = 6,500K BXRE – 30 E 200 0 – C – 8 3 Color Targeting Designator 0 = Cold Targeted 1 = Hot Targeted C = Décor Series Showcase Target Gen. 8Nominal CCT Flux Indicator 200x = 2000 lm Fully engineered substrate for consistent thermal, mechanical and optical properties Yellow phosphor Light Emitting Surface (LES) Note: Part number and lot codes are scribed on back of array Polarity symbols Solder Pads White ring around LES Case Temperature (Tc) Measurement Point Designed to comply with global safety standards for creepage and clearance distances Bridgelux arrays are fully engineered devices that provide consistent thermal and optical performance on an engineered mechanical platform. The V Series arrays are the most compact chip-on-board devices across all of Bridgelux’s LED Array products. The arrays incorporate several features to simplify design integration and assembly. Please visit www.bridgelux.com for more information on the V Series family of products.

The following product configurations are available: Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25°C (lm) Minimum Pulsed Flux6,7 Tc = 25°C (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRE-22C2001-B-8x 2200 70 350 1994 1795 33.4 11.7 171 BXRE-22C2001-C-8x 2200 70 500 2849 2564 33.4 16.7 171 BXRE-22E2000-B-8X 2200 80 350 1648 1483 33.4 11.7 141 BXRE-22E2000-C-8X 2200 80 500 2354 2118 33.4 16.7 141 BXRE-22G2000-B-8X 2200 90 350 1338 1204 33.4 11.7 114 BXRE-22G2000-C-8X 2200 90 500 1911 1719 33.4 16.7 114 BXRE-24G2000-B-8x 2400 90 350 1468 1321 33.4 11.7 126 BXRE-24G2000-C-8x 2400 90 500 2098 1888 33.4 16.7 126 BXRE-24H2000-B-8x 2400 97 350 1270 1143 33.4 11.7 109 BXRE-24H2000-C-8x 2400 97 500 1815 1634 33.4 16.7 109 BXRE-27C2001-B-8x 2700 70 350 2200 1980 33.4 11.7 188 BXRE-27C2001-C-8x 2700 70 500 3143 2829 33.4 16.7 188 BXRE-27E2000-B-8x 2700 80 350 1963 1767 33.4 11.7 168 BXRE-27E2000-C-8x 2700 80 500 2805 2524 33.4 16.7 168 BXRE-27G2000-B-8x 2700 90 350 1620 1458 33.4 11.7 139 BXRE-27G2000-C-8x 2700 90 500 2314 2082 33.4 16.7 139 BXRE-27G20H0-B-8x 2700 90 350 1690 1521 33.4 11.7 145 BXRE-27G20H0-C-8x 2700 90 500 2414 2172 33.4 16.7 145 BXRE-27H2000-B-8x 2700 97 350 1436 1292 33.4 11.7 123 BXRE-27H2000-C-8x 2700 97 500 2051 1846 33.4 16.7 123 BXRE-30C2001-B-8x 3000 70 350 2184 1966 33.4 11.7 187 BXRE-30C2001-C-8x 3000 70 500 3120 2808 33.4 16.7 187 BXRE-30E2000-B-8x 3000 80 350 2086 1877 33.4 11.7 178 BXRE-30E2000-C-8x 3000 80 500 2980 2682 33.4 16.7 178 BXRE-30G2000-B-8x 3000 90 350 1693 1524 33.4 11.7 145 BXRE-30G2000-C-8x 3000 90 500 2419 2177 33.4 16.7 145 BXRE-30G20H0-B-8x 3000 90 350 1773 1596 33.4 11.7 152 BXRE-30G20H0-C-8x 3000 90 500 2533 2280 33.4 16.7 152 BXRE-30H2000-B-8x 3000 97 350 1534 1380 33.4 11.7 131 BXRE-30H2000-C-8x 3000 97 500 2191 1972 33.4 16.7 131 BXRE-35E2000-B-8x 3500 80 350 2135 1922 33.4 11.7 183 BXRE-35E2000-C-8x 3500 80 500 3050 2745 33.4 16.7 183 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Décor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, Minimum R9 value is 60 for 90 CRI products on 2700K/3000K/3500K and 4000K, it is 50 on 5000K/5700K and 6500K. But for the CRI90 H0 products (higher efficiency CRI90 version), minimum R9 value is 55 on 2700K/3000K/3500K and 4000K. Minimum R9 value for 97 CRI products is 93 on 2700K and 3000K,and it is 85 on 3500K /4000K/5000K and 5700K. Bridgelux maintains a ± 3 tolerance on R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal drive current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal drive current are guaranteed by 100% test.

The following product configurations are available: Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C)(continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25°C (lm) Minimum Pulsed Flux6,7 Tc = 25°C (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRE-35G2000-B-8x 3500 90 350 1755 1579 33.4 11.7 150 BXRE-35G2000-C-8x 3500 90 500 2507 2256 33.4 16.7 150 BXRE-35H2000-B-8x 3500 97 350 1577 1419 33.4 11.7 135 BXRE-35H2000-C-8x 3500 97 500 2252 2027 33.4 16.7 135 BXRE-40C2001-B-8x 4000 70 350 2246 2021 33.4 11.7 192 BXRE-40C2001-C-8x 4000 70 500 3208 2887 33.4 16.7 192 BXRE-40E2000-B-8x 4000 80 350 2147 1933 33.4 11.7 184 BXRE-40E2000-C-8x 4000 80 500 3068 2761 33.4 16.7 184 BXRE-40G2000-B-8x 4000 90 350 1792 1612 33.4 11.7 153 BXRE-40G2000-C-8x 4000 90 500 2559 2303 33.4 16.7 153 BXRE-40H2000-B-8x 4000 95 350 1610 1449 33.4 11.7 138 BXRE-40H2000-C-8x 4000 95 500 2300 2070 33.4 16.7 138 BXRE-50C2001-B-8x 5000 70 350 2258 2032 33.4 11.7 193 BXRE-50C2001-C-8x 5000 70 500 3225 2903 33.4 16.7 193 BXRE-50E2001-B-8x 5000 80 350 2172 1955 33.4 11.7 186 BXRE-50E2001-C-8x 5000 80 500 3103 2792 33.4 16.7 186 BXRE-50G2001-B-8x 5000 90 350 1877 1690 33.4 11.7 161 BXRE-50G2001-C-8x 5000 90 500 2548 2293 33.4 16.7 161 BXRE-57C2001-B-8x 5700 70 350 2196 1977 33.4 11.7 188 BXRE-57C2001-C-8x 5700 70 500 3138 2824 33.4 16.7 188 BXRE-57E2001-B-8x 5700 80 350 2086 1877 33.4 11.7 178 BXRE-57E2001-C-8x 5700 80 500 2980 2682 33.4 16.7 178 BXRE-65C2001-B-8x 6500 70 350 2196 1977 33.4 11.7 188 BXRE-65C2001-C-8x 6500 70 500 3138 2824 33.4 16.7 188 BXRE-65E2001-B-8x 6500 80 350 2111 1899 33.4 11.7 181 BXRE-65E2001-C-8x 6500 80 500 3015 2714 33.4 16.7 181 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Décor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, Minimum R9 value is 60 for 90 CRI products on 2700K/3000K/3500K and 4000K, it is 50 on 5000K/5700K and 6500K. But for the CRI90 H0 products (higher efficiency CRI90 version), minimum R9 value is 55 on 2700K/3000K/3500K and 4000K. Minimum R9 value for 97 CRI products is 93 on 2700K and 3000K,and it is 85 on 3500K /4000K/5000K and 5700K. Bridgelux maintains a ± 3 tolerance on R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal drive current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal drive current are guaranteed by 100% test.

Table 2: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85°C (lm) Minimum DC Flux6 Tc = 85°C (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRE-22C2001-B-8x 2200 70 350 1795 1615 32.7 11.4 157 BXRE-22C2001-C-8x 2200 70 500 2564 2307 32.7 16.3 157 BXRE-22E2000-B-8X 2200 80 350 1483 1335 32.7 11.4 130 BXRE-22E2000-C-8X 2200 80 500 2118 1907 32.7 16.3 130 BXRE-22G2000-B-8X 2200 90 350 1204 1084 32.7 11.4 106 BXRE-22G2000-C-8X 2200 90 500 1719 1548 32.7 16.3 105 BXRE-24G2000-B-8x 2400 90 350 1321 1189 32.7 11.4 116 BXRE-24G2000-C-8x 2400 90 500 1888 1699 32.7 16.3 116 BXRE-24H2000-B-8x 2400 97 350 1143 1029 32.7 11.4 100 BXRE-24H2000-C-8x 2400 97 500 1634 1470 32.7 16.3 100 BXRE-27C2001-B-8x 2700 70 350 1980 1782 32.7 11.4 173 BXRE-27C2001-C-8x 2700 70 500 2829 2546 32.7 16.3 173 BXRE-27E2000-B-8x 2700 80 350 1767 1590 32.7 11.4 154 BXRE-27E2000-C-8x 2700 80 500 2524 2272 32.7 16.3 154 BXRE-27G2000-B-8x 2700 90 350 1458 1312 32.7 11.4 127 BXRE-27G2000-C-8x 2700 90 500 2082 1874 32.7 16.3 127 BXRE-27G20H0-B-8x 2700 90 350 1521 1369 32.7 11.4 133 BXRE-27G20H0-C-8x 2700 90 500 2172 1955 32.7 16.3 133 BXRE-27H2000-B-8x 2700 97 350 1292 1163 32.7 11.4 113 BXRE-27H2000-C-8x 2700 97 500 1846 1661 32.7 16.3 113 BXRE-30C2001-B-8x 3000 70 350 1966 1769 32.7 11.4 172 BXRE-30C2001-C-8x 3000 70 500 2808 2527 32.7 16.3 172 BXRE-30E2000-B-8x 3000 80 350 1877 1690 32.7 11.4 164 BXRE-30E2000-C-8x 3000 80 500 2682 2414 32.7 16.3 164 BXRE-30G2000-B-8x 3000 90 350 1524 1372 32.7 11.4 133 BXRE-30G2000-C-8x 3000 90 500 2177 1959 32.7 16.3 133 BXRE-30G20H0-B-8x 3000 90 350 1596 1436 32.7 11.4 140 BXRE-30G20H0-C-8x 3000 90 500 2280 2052 32.7 16.3 140 BXRE-30H2000-B-8x 3000 97 350 1380 1242 32.7 11.4 121 BXRE-30H2000-C-8x 3000 97 500 1972 1775 32.7 16.3 121 BXRE-35E2000-B-8x 3500 80 350 1922 1729 32.7 11.4 168 BXRE-35E2000-C-8x 3500 80 500 2745 2471 32.7 16.3 168 Notes for Table 2: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Décor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, Minimum R9 value is 60 for 90 CRI products on 2700K/3000K/3500K and 4000K, it is 50 on 5000K/5700K and 6500K. But for the CRI90 H0 products (higher efficiency CRI90 version), minimum R9 value is 55 on 2700K/3000K/3500K and 4000K. Minimum R9 value for 97 CRI products is 93 on 2700K and 3000K,and it is 85 on 3500K /4000K/5000K and 5700K. Bridgelux maintains a ± 3 tolerance on R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.

Table 2: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85°C (lm) Minimum DC Flux6 Tc = 85°C (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRE-35G2000-B-8x 3500 90 350 1579 1421 32.7 11.4 138 BXRE-35G2000-C-8x 3500 90 500 2256 2030 32.7 16.3 138 BXRE-35H2000-B-8x 3500 97 350 1419 1277 32.7 11.4 124 BXRE-35H2000-C-8x 3500 97 500 2027 1824 32.7 16.3 124 BXRE-40C2001-B-8x 4000 70 350 2021 1819 32.7 11.4 177 BXRE-40C2001-C-8x 4000 70 500 2887 2598 32.7 16.3 177 BXRE-40E2000-B-8x 4000 80 350 1933 1739 32.7 11.4 169 BXRE-40E2000-C-8x 4000 80 500 2761 2485 32.7 16.3 169 BXRE-40G2000-B-8x 4000 90 350 1612 1451 32.7 11.4 141 BXRE-40G2000-C-8x 4000 90 500 2303 2073 32.7 16.3 141 BXRE-40H2000-B-8x 4000 95 350 1449 1304 32.7 11.4 127 BXRE-40H2000-C-8x 4000 95 500 2070 1863 32.7 16.3 127 BXRE-50C2001-B-8x 5000 70 350 2032 1829 32.7 11.4 178 BXRE-50C2001-C-8x 5000 70 500 2903 2613 32.7 16.3 178 BXRE-50E2001-B-8x 5000 80 350 1955 1759 32.7 11.4 171 BXRE-50E2001-C-8x 5000 80 500 2792 2513 32.7 16.3 171 BXRE-50G2001-B-8x 5000 90 350 1690 1521 32.7 11.4 148 BXRE-50G2001-C-8x 5000 90 500 2293 2063 32.7 16.3 148 BXRE-57C2001-B-8x 5700 70 350 1977 1779 32.7 11.4 173 BXRE-57C2001-C-8x 5700 70 500 2824 2542 32.7 16.3 173 BXRE-57E2001-B-8x 5700 80 350 1877 1690 32.7 11.4 164 BXRE-57E2001-C-8x 5700 80 500 2682 2414 32.7 16.3 164 BXRE-65C2001-B-8x 6500 70 350 1977 1779 32.7 11.4 173 BXRE-65C2001-C-8x 6500 70 500 2824 2542 32.7 16.3 173 BXRE-65E2001-B-8x 6500 80 350 1899 1710 32.7 11.4 166 BXRE-65E2001-C-8x 6500 80 500 2714 2442 32.7 16.3 166 Notes for Table 2: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Décor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, Minimum R9 value is 60 for 90 CRI products on

European Product Registry for Energy Labeling The European Product Registry for Energy Labeling (EPREL) is defined in the EU Regulation 2017/1369 to provide import- ant energy efficiency information to consumers. Together with Energy Labeling Regulation ELR (EU) 2019/2015 which was amended by regulation (EU) 2021/340 for energy labelling of light sources, manufacturers are required to declare an ener- gy class based on key technical specifications from each of their product and register it in an open data base managed by EPREL It is now a legal requirement for a vendor of light sources to upload information about their products into the EPREL database before placing these products on the market in the EU. Table 3 below provides a list of part numbers that are in compliance with ELR and are currently listed in the EPREL data- base. At Bridgelux, we are fully committed to supplying products that are compliant with pertinent laws, rules, and obligation imposed by relevant government bodies including the European Energy Labeling regulation. Customers can use these products with full confidence for any projects that fall under the ELR. Table 3: Part numbers registered in European Product Registry for Energy Labeling PART NUMBER1 CCT (K) CRI Current2 (mA) Vf (V) Useful flux3 (Φuse) at 85C (lm) Pow- er (W) Efficacy (lm/W) Energy efficiency class4 Regis- tration No URL to Product Information Sheet in EPREL Database Notes for Table 3: 1. All device listed here must be disposed as e-waste upon its end of life according to local country guideline in each country. 2. For information on performance values at alternative drive conditions. please refer to the Product Selection Guide, Absolute Maximum Rating Table and Performance Curves in this data sheet. 3. For a definition of useful luminous flux (ΦΦuse), please see the ELR regulations at https:/ /tinyurl.com/4b6zvt4m. 4. EPREL requires an arrow symbol containing the letter of the energy efficiency class to be displayed. on technical promotional material. Refer to this energy efficiency class column for specific energy efficiency class on each part number.

European Product Registry for Energy Labeling Table 3: Part numbers registered in European Product Registry for Energy Labeling (Continued) PART NUMBER1 CCT (K) CRI Current2 (mA) Vf (V) Useful flux3 (Φuse) at 85C (lm) Pow- er (W) Efficacy (lm/W) Energy efficiency class4 Regis- tration No URL to Product Information Sheet in EPREL Database BXRE-35H2000-B-83 3500 95 1080 36.1 4132 39 106 F 2366248 https:/ /eprel.ec.europa.eu/qr/2366248 BXRE-35H2000-C-83 3500 95 1420 35.7 5423 51 107 F 2366249 https:/ /eprel.ec.europa.eu/qr/2366249 Notes for Table 3: 1. All device listed here must be disposed as e-waste upon its end of life according to local country guideline in each country. 2. For information on performance values at alternative drive conditions. please refer to the Product Selection Guide, Absolute Maximum Rating Table and Performance Curves in this data sheet. 3. For a definition of useful luminous flux (ΦΦuse), please see the ELR regulations at https:/ /tinyurl.com/4b6zvt4m. 4. EPREL requires an arrow symbol containing the letter of the energy efficiency class to be displayed. on technical promotional material. Refer to this energy efficiency class column for specific energy efficiency class on each part number.

Performance at Commonly Used Drive Currents V Series LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. V Series may also be driven at other drive currents dependent on specific application design requirements. The performance at any drive current can be derived from the current vs. voltage characteristics shown in Figures 1 & 2 and the flux vs. current characteristics shown in Figures 3 & 4. The performance at commonly used drive currents is summarized in Table 4. Table 4: Product Performance at Commonly Used Drive Currents Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25°C (V) Typical Power Tc = 25°C (W) Typical Flux2 Tc = 25°C (lm) Typical DC Flux3 Tc = 85°C (lm) Typical Efficacy Tc = 25°C (lm/W) BXRE-22C2001-B-8x 70 175 32.4 5.7 1034 931 182 260 32.9 8.6 1500 1350 175 350 33.4 11.7 1994 1795 171 450 33.9 15.3 2517 2265 165 700 35.2 24.6 3809 3428 155 1250 37.6 47.0 6463 5816 138 BXRE-22C2001-C-8x 70 250 32.5 8.1 1478 1330 182 375 33.0 12.4 2162 1945 175 500 33.4 16.7 2849 2564 170 630 33.9 21.4 3528 3175 165 1000 35.2 35.2 5441 4897 155 1750 37.5 65.7 9068 8161 138 BXRE-22E2000-B-8X 80 175 32.4 5.7 855 769 150 260 32.9 8.6 1240 1115 144 350 33.4 11.7 1648 1483 141 450 33.9 15.3 2080 1872 136 700 35.2 24.6 3148 2832 128 1250 37.6 47.0 5341 4806 114 BXRE-22E2000-C-8X 80 250 32.5 8.1 1221 1099 151 375 33.0 12.4 1786 1607 144 500 33.4 16.7 2354 2118 141 630 33.9 21.4 2916 2624 136 1000 35.2 35.2 4497 4046 128 1750 37.5 65.7 7494 6743 114 BXRE-22G2000-B-8X 90 175 32.4 5.7 694 624 122 260 32.9 8.6 1006 905 117 350 33.4 11.7 1338 1204 114 450 33.9 15.3 1688 1519 110 700 35.2 24.6 2555 2299 104 1250 37.6 47.0 4336 3901 92 BXRE-22G2000-C-8X 90 250 32.5 8.1 991 892 122 375 33.0 12.4 1450 1305 117 500 33.4 16.7 1911 1719 114 630 33.9 21.4 2367 2129 111 1000 35.2 35.2 3650 3284 104 1750 37.6 65.7 6083 5474 93 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25°C (V) Typical Power Tc = 25°C (W) Typical Flux2 Tc = 25°C (lm) Typical DC Flux3 Tc = 85°C (lm) Typical Efficacy Tc = 25°C (lm/W) BXRE-24G2000-B-8X 90 175 32.4 5.7 761 685 134 260 32.9 8.6 1103 993 129 350 33.4 11.7 1468 1321 126 450 33.9 15.3 1852 1667 121 700 35.2 24.6 2803 2523 114 1250 37.6 47.0 4756 4281 101 BXRE-24G2000-C-8X 90 250 32.5 8.1 1089 980 134 375 33 12.4 1592 1433 129 500 33.4 16.7 2098 1888 126 630 33.9 21.4 2599 2339 122 1000 35.2 35.2 4007 3607 114 1750 37.6 65.8 6679 6011 102 BXRE-24H2000-B-8X 97 175 32.4 5.7 658 593 116 260 32.9 8.6 955 859 112 350 33.4 11.7 1270 1143 109 450 33.9 15.3 1602 1442 105 700 35.2 24.6 2425 2183 98 1250 37.6 47.0 4115 3703 88 BXRE-24H2000-C-8X 97 250 32.5 8.1 942 848 116 375 33 12.4 1377 1240 111 500 33.4 16.7 1815 1634 109 630 33.9 21.4 2248 2024 105 1000 35.2 35.2 3467 3120 98 1750 37.6 65.8 5778 5201 88 BXRE-27C2001-B-8x 70 175 32.4 5.7 1141 1027 201 260 32.9 8.6 1655 1489 193 350 33.4 11.7 2200 1980 188 450 33.9 15.3 2777 2499 182 700 35.2 24.6 4202 3782 171 1250 37.6 47 7131 6418 152 BXRE-27C2001-C-8x 70 250 32.5 8.1 1631 1468 201 375 33 12.4 2385 2147 193 500 33.4 16.7 3143 2829 188 630 33.9 21.4 3892 3503 182 1000 35.2 35.2 6003 5403 170 1750 37.5 65.7 10005 9005 152 BXRE-27E2000-B-8x 80 175 32.4 5.7 1019 917 179 260 32.9 8.6 1476 1329 173 350 33.4 11.7 1963 1767 168 450 33.9 15.3 2478 2230 162 700 35.2 24.6 3750 3375 152 1250 37.6 47 6363 5727 135 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Table 4: Product Performance at Commonly Used Drive Currents (Continued) Performance at Commonly Used Drive Currents Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25°C (V) Typical Power Tc = 25°C (W) Typical Flux2 Tc = 25°C (lm) Typical DC Flux3 Tc = 85°C (lm) Typical Efficacy Tc = 25°C (lm/W) BXRE-27E2000-C-8x 80 250 32.5 8.1 1455 1310 179 375 33 12.4 2128 1916 172 500 33.4 16.7 2805 2524 168 630 33.9 21.4 3473 3126 163 1000 35.2 35.2 5357 4821 152 1750 37.5 65.7 8928 8035 136 BXRE-27G2000-B-8x 90 175 32.4 5.7 840 756 148 260 32.9 8.6 1218 1096 142 350 33.4 11.7 1620 1458 139 450 33.9 15.3 2044 1840 134 700 35.2 24.6 3094 2784 126 1250 37.6 47 5250 4725 112 BXRE-27G2000-C-8x 90 250 32.5 8.1 1200 1080 148 375 33 12.4 1756 1580 142 500 33.4 16.7 2314 2082 138 630 33.9 21.4 2866 2579 134 1000 35.2 35.2 4420 3978 126 1750 37.5 65.7 7366 6629 112 BXRE-27G20H0-B-8x 90 175 32.4 5.7 877 789 154 260 32.9 8.6 1271 1144 149 350 33.4 11.7 1690 1521 145 450 33.9 15.3 2133 1920 140 700 35.2 24.6 3227 2905 131 1250 37.6 47 5476 4929 117 BXRE-27G20H0-C-8x 90 250 32.5 8.1 1252 1127 154 375 33 12.4 1832 1649 148 500 33.4 16.7 2414 2172 144 630 33.9 21.4 2989 2690 140 1000 35.2 35.2 4610 4149 131 1750 37.5 65.7 7684 6916 117 BXRE-27H2000-B-8x 97 175 32.4 5.7 745 670 131 260 32.9 8.6 1080 972 126 350 33.4 11.7 1436 1292 123 450 33.9 15.3 1812 1631 119 700 35.2 24.6 2742 2468 111 1250 37.6 47 4653 4188 99 BXRE-27H2000-C-8x 97 250 32.5 8.1 1064 958 131 375 33 12.4 1556 1401 126 500 33.4 16.7 2051 1846 123 630 33.9 21.4 2540 2286 119 1000 35.2 35.2 3917 3526 111 1750 37.5 65.7 6529 5876 99 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25°C (V) Typical Power Tc = 25°C (W) Typical Flux2 Tc = 25°C (lm) Typical DC Flux3 Tc = 85°C (lm) Typical Efficacy Tc = 25°C (lm/W) BXRE-30C2001-B-8x 70 175 32.4 5.7 1133 1020 200 260 32.9 8.6 1643 1478 192 350 33.4 11.7 2184 1966 187 450 33.9 15.3 2757 2481 181 700 35.2 24.6 4172 3755 169 1250 37.6 47 7079 6371 151 BXRE-30C2001-C-8x 70 250 32.5 8.1 1619 1457 199 375 33 12.4 2368 2131 192 500 33.4 16.7 3120 2808 187 630 33.9 21.4 3864 3478 181 1000 35.2 35.2 5960 5364 169 1750 37.5 65.7 9933 8939 151 BXRE-30E2000-B-8x 80 175 32.4 5.7 1082 974 191 260 32.9 8.6 1569 1412 183 350 33.4 11.7 2086 1877 178 450 33.9 15.3 2633 2370 172 700 35.2 24.6 3984 3586 162 1250 37.6 47 6761 6085 144 BXRE-30E2000-C-8x 80 250 32.5 8.1 1546 1391 190 375 33 12.4 2261 2035 183 500 33.4 16.7 2980 2682 178 630 33.9 21.4 3691 3321 173 1000 35.2 35.2 5692 5123 162 1750 37.5 65.7 9486 8538 144 BXRE-30G2000-B-8x 90 175 32.4 5.7 878 791 155 260 32.9 8.6 1273 1146 149 350 33.4 11.7 1693 1524 145 450 33.9 15.3 2137 1924 140 700 35.2 24.6 3234 2911 131 1250 37.6 47 5488 4939 117 BXRE-30G2000-C-8x 90 250 32.5 8.1 1255 1129 155 375 33 12.4 1836 1652 149 500 33.4 16.7 2419 2177 145 630 33.9 21.4 2996 2696 140 1000 35.2 35.2 4621 4158 131 1750 37.5 65.7 7701 6931 117 BXRE-30G20H0-B-8x 90 175 32.4 5.7 920 828 162 260 32.9 8.6 1333 1200 156 350 33.4 11.7 1773 1596 152 450 33.9 15.3 2238 2014 147 700 35.2 24.6 3387 3048 138 1250 37.6 47 5747 5172 122 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25°C (V) Typical Power Tc = 25°C (W) Typical Flux2 Tc = 25°C (lm) Typical DC Flux3 Tc = 85°C (lm) Typical Efficacy Tc = 25°C (lm/W) BXRE-30G20H0-C-8x 90 250 32.5 8.1 1314 1183 162 375 33 12.4 1922 1730 156 500 33.4 16.7 2533 2280 152 630 33.9 21.4 3137 2823 147 1000 35.2 35.2 4838 4354 137 1750 37.5 65.7 8063 7257 123 BXRE-30H2000-B-8x 97 175 32.4 5.7 796 716 140 260 32.9 8.6 1154 1038 135 350 33.4 11.7 1534 1380 131 450 33.9 15.3 1936 1742 127 700 35.2 24.6 2930 2637 119 1250 37.6 47 4971 4474 106 BXRE-30H2000-C-8x 97 250 32.5 8.1 1137 1023 140 375 33 12.4 1663 1497 135 500 33.4 16.7 2191 1972 131 630 33.9 21.4 2714 2442 127 1000 35.2 35.2 4185 3767 119 1750 37.5 65.7 6975 6278 106 BXRE-35E2000-B-8x 80 175 32.4 5.7 1108 997 195 260 32.9 8.6 1606 1445 188 350 33.4 11.7 2135 1922 183 450 33.9 15.3 2695 2426 177 700 35.2 24.6 4078 3670 166 1250 37.6 47 6920 6228 147 BXRE-35E2000-C-8x 80 250 32.5 8.1 1582 1424 195 375 33 12.4 2315 2083 187 500 33.4 16.7 3050 2745 182 630 33.9 21.4 3777 3400 177 1000 35.2 35.2 5826 5243 165 1750 37.5 65.7 9710 8739 148 BXRE-35G2000-B-8x 90 175 32.4 5.7 910 819 160 260 32.9 8.6 1320 1188 154 350 33.4 11.7 1755 1579 150 450 33.9 15.3 2215 1993 145 700 35.2 24.6 3352 3016 136 1250 37.6 47 5687 5118 121 BXRE-35G2000-C-8x 90 250 32.5 8.1 1300 1170 160 375 33 12.4 1902 1712 154 500 33.4 16.7 2507 2256 150 630 33.9 21.4 3104 2794 145 1000 35.2 35.2 4788 4309 136 1750 37.5 65.7 7980 7182 121 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25°C (V) Typical Power Tc = 25°C (W) Typical Flux2 Tc = 25°C (lm) Typical DC Flux3 Tc = 85°C (lm) Typical Efficacy Tc = 25°C (lm/W) BXRE-40C2001-B-8x 70 175 32.4 5.7 1165 1048 205 260 32.9 8.6 1689 1520 197 350 33.4 11.7 2246 2021 192 450 33.9 15.3 2834 2551 186 700 35.2 24.6 4289 3860 174 1250 37.6 47 7278 6550 155 BXRE-35E2000-C-8x 80 250 32.5 8.1 1582 1424 195 375 33 12.4 2315 2083 187 500 33.4 16.7 3050 2745 182 630 33.9 21.4 3777 3400 177 1000 35.2 35.2 5826 5243 165 1750 37.5 65.7 9710 8739 148 BXRE-35G2000-B-8x 90 175 32.4 5.7 910 819 160 260 32.9 8.6 1320 1188 154 350 33.4 11.7 1755 1579 150 450 33.9 15.3 2215 1993 145 700 35.2 24.6 3352 3016 136 1250 37.6 47 5687 5118 121 BXRE-35G2000-C-8x 90 250 32.5 8.1 1300 1170 160 375 33 12.4 1902 1712 154 500 33.4 16.7 2507 2256 150 630 33.9 21.4 3104 2794 145 1000 35.2 35.2 4788 4309 136 1750 37.5 65.7 7980 7182 121 BXRE-35H2000-B-8x 97 175 32.4 5.7 818 736 144 260 32.9 8.6 1186 1067 139 350 33.4 11.7 1577 1419 135 450 33.9 15.3 1990 1791 130 700 35.2 24.6 3011 2710 122 1250 37.6 47.0 5110 4599 109 BXRE-35H2000-C-8x 97 250 32.5 8.1 1168 1052 144 375 33.0 12.4 1709 1538 138 500 33.4 16.7 2252 2027 135 630 33.9 21.4 2789 2510 131 1000 35.2 35.2 4302 3872 122 1750 37.5 65.7 7170 6453 109 BXRE-40G2000-B-8x 90 175 32.4 5.7 929 836 164 260 32.9 8.6 1347 1213 157 350 33.4 11.7 1792 1612 153 450 33.9 15.3 2261 2035 148 700 35.2 24.6 3422 3080 139 1250 37.6 47 5806 5226 124 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25°C (V) Typical Power Tc = 25°C (W) Typical Flux2 Tc = 25°C (lm) Typical DC Flux3 Tc = 85°C (lm) Typical Efficacy Tc = 25°C (lm/W) BXRE-40G2000-C-8x 90 250 32.5 8.1 1328 1195 164 375 33 12.4 1942 1748 157 500 33.4 16.7 2559 2303 153 630 33.9 21.4 3170 2853 148 1000 35.2 35.2 4888 4400 139 1750 37.5 65.7 8147 7332 124 BXRE-40H2000-B-8x 90 175 32.4 5.7 835 751 147 260 32.9 8.6 1210 1089 141 350 33.4 11.7 1610 1449 138 450 33.9 15.3 2031 1828 133 700 35.2 24.6 3074 2767 125 1250 37.6 47.0 5216 4695 111 BXRE-40H2000-C-8x 90 250 32.5 8.1 1194 1074 147 375 33 12.4 1745 1571 141 500 33.4 16.7 2300 2070 138 630 33.9 21.4 2849 2564 133 1000 35.2 35.2 4393 3954 125 1750 37.5 65.7 7322 6590 111 BXRE-50C2001-B-8x 70 175 32.4 5.7 1171 1054 206 260 32.9 8.6 1698 1528 198 350 33.4 11.7 2258 2032 193 450 33.9 15.3 2850 2565 187 700 35.2 24.6 4312 3881 175 1250 37.6 47 7318 6586 156 BXRE-50C2001-C-8x 70 250 32.5 8.1 1673 1506 206 375 33 12.4 2448 2203 198 500 33.4 16.7 3225 2903 193 630 33.9 21.4 3994 3595 187 1000 35.2 35.2 6161 5545 175 1750 37.5 65.7 10268 9241 156 BXRE-50E2001-B-8x 80 175 32.4 5.7 1127 1014 198 260 32.9 8.6 1633 1470 191 350 33.4 11.7 2172 1955 186 450 33.9 15.3 2741 2467 180 700 35.2 24.6 4148 3734 168 1250 37.6 47 7039 6335 150 BXRE-50E2001-C-8x 80 250 32.5 8.1 1610 1449 198 375 33 12.4 2355 2119 190 500 33.4 16.7 3103 2792 186 630 33.9 21.4 3842 3458 180 1000 35.2 35.2 5926 5334 168 1750 37.5 65.7 9877 8889 150 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25°C (V) Typical Power Tc = 25°C (W) Typical Flux2 Tc = 25°C (lm) Typical DC Flux3 Tc = 85°C (lm) Typical Efficacy Tc = 25°C (lm/W) BXRE-50G2001-B-8x 90 175 32.4 5.7 974 877 172 260 32.9 8.6 1412 1271 165 350 33.4 11.7 1877 1690 161 450 33.9 15.3 2370 2133 155 700 35.2 24.6 3586 3227 146 1250 37.6 47 6085 5476 129 BXRE-50G2001-C-8x 90 250 32.5 8.1 1321 1189 171 375 33 12.4 1933 1740 165 500 33.4 16.7 2548 2293 160 630 33.9 21.4 3155 2840 155 1000 35.2 35.2 4867 4380 145 1750 37.5 65.7 8111 7300 130 BXRE-57C2001-B-8x 70 175 32.4 5.7 1139 1026 201 260 32.9 8.6 1652 1487 193 350 33.4 11.7 2196 1977 188 450 33.9 15.3 2772 2495 182 700 35.2 24.6 4195 3776 170 1250 37.6 47 7119 6407 151 BXRE-57C2001-C-8x 70 250 32.5 8.1 1628 1465 200 375 33 12.4 2381 2143 193 500 33.4 16.7 3138 2824 188 630 33.9 21.4 3886 3497 182 1000 35.2 35.2 5993 5394 170 1750 37.5 65.7 9989 8990 152 BXRE-57E2001-B-8x 80 175 32.4 5.7 1082 974 191 260 32.9 8.6 1569 1412 183 350 33.4 11.7 2086 1877 178 450 33.9 15.3 2633 2370 172 700 35.2 24.6 3984 3586 162 1250 37.6 47 6761 6085 144 BXRE-57E2001-C-8x 80 250 32.5 8.1 1546 1391 190 375 33 12.4 2261 2035 183 500 33.4 16.7 2980 2682 178 630 33.9 21.4 3691 3321 173 1000 35.2 35.2 5692 5123 162 1750 37.5 65.7 9486 8538 144 BXRE-65C2001-B-8x 70 175 32.4 5.7 1139 1026 201 260 32.9 8.6 1652 1487 193 350 33.4 11.7 2196 1977 188 450 33.9 15.3 2772 2495 182 700 35.2 24.6 4195 3776 170 1250 37.6 47 7119 6407 151 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25°C (V) Typical Power Tc = 25°C (W) Typical Flux2 Tc = 25°C (lm) Typical DC Flux3 Tc = 85°C (lm) Typical Efficacy Tc = 25°C (lm/W) BXRE-65C2001-C-8x 70 250 32.5 8.1 1628 1465 200 375 33 12.4 2381 2143 193 500 33.4 16.7 3138 2824 188 630 33.9 21.4 3886 3497 182 1000 35.2 35.2 5993 5394 170 1750 37.5 65.7 9989 8990 152 BXRE-65E2001-B-8x 80 175 32.4 5.7 1095 985 193 260 32.9 8.6 1587 1428 185 350 33.4 11.7 2111 1899 181 450 33.9 15.3 2664 2398 175 700 35.2 24.6 4031 3628 164 1250 37.6 47 6840 6156 146 BXRE-65E2001-C-8x 80 250 32.5 8.1 1564 1408 193 375 33 12.4 2288 2059 185 500 33.4 16.7 3015 2714 180 630 33.9 21.4 3734 3361 175 1000 35.2 35.2 5759 5183 164 1750 37.5 65.7 9598 8638 146 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Electrical Characteristics

Table 5: Electrical Characteristics Part Number Drive Current (mA) Forward Voltage Pulsed, Tc = 25°C (V) 1, 2, 3, 8 Typical Coefficient of Forward Voltage4 ∆Vf/∆Tc (mV/°C) Typical Thermal Resistance Junction to Case5,6 Rj-c (°C/W) Driver Selection Voltages7 (V) Minimum Typical Maximum Vf Min. Hot Tc = 105°C (V) Vf Max. Cold Tc = -40°C (V) BXRE-xxx200x-B-8x BXRE-xxx200x-C-8x Notes for Table 5: 1. Parts are tested in pulsed conditions, Tc = 25°C. Pulse width is 10ms. 2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance. 3. Bridgelux maintains a tester tolerance of ± 0.10V on forward voltage measurements. 4. Typical coefficient of forward voltage tolerance is ± 0.1mV for nominal current. 5. Thermal resistance values are based from test data of a 3000K 80 CRI product. 6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal interface material used during testing is not included in the thermal resistance value. 7. Vf min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design and selec- tion over the operating range of the product. 8. This product has been designed and manufactured per IEC 62031:2018. This product has passed dielectric withstand voltage testing at 1140 V. The working voltage designated for the insulation is 70V d.c. The maximum allowable voltage across the array must be determined in the end product application.

Table 6: Eye Safety Risk Group (RG) Classifications Part Number Drive Current (mA) CCT5 2700K/3000K 4000K2 5000K3 6500K4 BXRE-xxx200x-B-8x

800 RG1 RG1 RG1 RG1

1110 RG1 RG1 RG1 RG2

1250 RG1 RG1 RG2 RG2

1470 RG1 RG1 RG2 RG2

1750 RG1 RG2 RG2 RG2

Notes for Table 6: 1. Eye safety classification for the use of Bridgelux V Series LED arrays is in accordance with specification IEC/TR 62778: Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires. 2. For products classified as RG2 at 4000K, Ethr= 1980 lx. 3. For products classified as RG2 at 5000K Ethr= 1530 lx. 4. For products classified as RG2 at 6500K, Ethr= 1170 lx. 5. Please contact your Bridgelux sales representative for Ethr values at specific drive currents and CCTs not listed.

Table 7: Maximum Ratings Parameter Maximum Rating LED Junction Temperature (Tj) 150°C Storage Temperature -40°C to +105°C Operating Case Temperature1 (Tc) 105°C Soldering Temperature2 350°C or lower for a maximum of 6 seconds BXRE-xxx200x-B-8x BXRE-xxx200x-C-8x Maximum Drive Current3 1250 mA 1750 mA Maximum Peak Pulsed Drive Current4 1400 mA 1960 mA Maximum Reverse Voltage5 -60V -60V Notes for Table 7: 1. For IEC 62717 requirement, please consult your Bridgelux sales representative. 2. Refer to Bridgelux Application Note AN101: Handling and Assembly of Bridgelux V Series LED Arrays 3. Arrays may be driven at higher currents however lumen maintenance may be reduced and warranty will not apply. 4. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed current specified. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures. 5. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating provided for reference only.

Figure 10: Typical Color Spectrum Notes for Figure 10: 1. Color spectra measured at nominal current for Tj = Tc = 25°C. 2. Color spectra shown is 3000K and 80 CRI. 3. Color spectra shown is 4000K and 80 CRI. 4. Color spectra shown is 5000K and 70 CRI. 4. Color spectra shown is 6500K and 70 CRI. 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 110% 400 450 500 550 600 650 700 750 800 Relative Spectral Power Distribution Wavelength (nm) 3000K 4000K 5000K 6500K

Figure 11: Drawing for V13 LED Array Notes for Figure 11: 1. Drawings are not to scale. 2. Drawing dimensions are in millimeters. 3. Unless otherwise specified, tolerances are ±0.1mm. 4. Solder pad labeled “+” denotes positive contact. 5. Refer to Application Notes AN101 for product handling, mounting and heat sink recommendations. 6. The optical center of the LED Array is nominally defined by the mechanical center of the array to a tolerance of ± 0.2mm. 7. Bridgelux maintains a flatness of 0.10mm across the mounting surface of the array.

Figure 12: Warm and Neutral White Test Bins in xy Color Space Figure 13: Cool White Test Bins in xy Color Space Color Binning Information Table 8: Warm and Neutral White xy Bin Coordinates and Associated Typical CCT Bin Code 5000K 5700K 6500K ANSI Bin (for reference only) (4745K - 5311K) (5312K - 6022K) (6022K - 7042K) 84 (4 SDCM) (4801K - 5282K) (5395K- 5970K) (6200K - 6910K) 83 (3 SDCM) (4835K - 5215K) (5460K- 5891K) (6279K -6811K) Table 9: Cool White xy Bin Coordinates and Associated Typical CCT (product is hot targeted to Tc = 85°C) Note: Pulsed Test Conditions, Tc = 25°C 0.3 0.31 0.32 0.33 0.34 0.35 0.36 0.37 0.38 0.39 Y X

4 SDCM

3 SDCM

Note for Tables 8-9: 1. Bridgelux maintains a tolerance of +/- 0.007 on x and y color coordinates in the CIE 1931 color Space. Bin Code 2200K 2400K 2700K 3000K 3500K 4000K ANSI Bin (for reference only) (2207K-2309K) (2300K-2500K) (2580K - 2870K) (2870K - 3220K) (3220K - 3710K) (3710K - 4260K) 83 (3 SDCM) (2207K-2309K) (2336K-2454K) (2651K - 2794K) (2968K - 3136K) (3369K - 3586K) (3851K - 4130K) 82 (2 SDCM) (2224K-2291K) (2355K-2433K) (2674K - 2769K) (2995K - 3107K) (3404K - 3548K) (3895K - 4081K)

Figure 14: Drawing for V13 Packaging Tubes Notes for Figure 14: 1. Each tube holds 25 V13 COB arrays. 2. One tube is sealed in an anti-static bag. Four bags are placed in a shipping box. Depending on quantities ordered, a bigger shipping box, containing four boxes may be used to ship products. 3. Each bag and box is to be labeled as shown above. box are 58.7 x 13.3 x 7.9 cm.

Figure 15: Gen. 8 Product Labeling Bridgelux COB arrays have laser markings on the back side of the substrate to help with product identification. In addition to the product identification markings, Bridgelux COB arrays also contain markings for internal Bridgelux manufacturing use only. The image below shows which markings are for customer use and which ones are for Bridgelux internal use only. The Bridgelux internal manufacturing markings are subject to change without notice, however these will not impact the form, function or performance of the COB array. Customer Use- 2D Barcode Scannable barcode provides product part number and other Bridgelux internal production information. Customer Use- Product part number Customer Use- Vf Bin Code included to enable greater luminaire design flexibility. Refer to AN92 for bin code definitions. 30E2000C 83 2F Internal Bin Code

Bridgelux has developed a comprehensive set of application notes and design resources to assist customers in successfully designing with the V Series product family of LED array products. For all available application notes visit www.bridgelux.com. Optical Source Models Optical source models and ray set files are available for all Bridgelux products. For a list of available formats, visit www.bridgelux.com. MINOR PRODUCT CHANGE POLICY The rigorous qualification testing on products offered by Bridgelux provides performance assurance. Slight cosmetic changes that do not affect form, fit, or function may occur as Bridgelux continues product optimization. CAUTION: CHEMICAL EXPOSURE HAZARD Exposure to some chemicals commonly used in luminaire manufacturing and assembly can cause damage to the LED array. Please consult Bridgelux CAUTION: RISK OF BURN Do not touch the V Series LED array during operation. Allow the array to cool for a sufficient period of time before handling. The V Series LED array may reach elevated temperatures such that could burn skin when touched. 3D CAD Models Three dimensional CAD models depicting the product outline of all Bridgelux V Series LED arrays are available in both IGS and STEP formats. Please contact your Bridgelux sales representative for assistance. LM80 LM80 testing has been completed and the LM80 report is now available. Please contact your Bridgelux sales representative for LM-80 report. STANDARD TEST CONDITIONS Unless otherwise stated, array testing is performed at the nominal drive current. CAUTION CONTACT WITH LIGHT EMITTING SURFACE (LES) Avoid any contact with the LES. Do not touch the LES of the LED array or apply stress to the LES (yellow phosphor resin area). Contact may cause damage to the LED array. Optics and reflectors must not be mounted in contact with the LES (yellow phosphor resin area).

About Bridgelux: Bridging Light and Life™ © 2025 Bridgelux, Inc. All rights reserved. Product specifications are subject to change without notice. Bridgelux, the Bridgelux stylized logo design and Vero are registered trademarks, V Series and Decor Series are trademarks of Bridgelux, Inc. All other trademarks are the property of their respective owners. Bridgelux Gen 8 V13 Array Series Product Data Sheet DS413 Rev. G (05/2025)

46410 Fremont Boulevard

Fremont, CA 94538 U.S.A. Tel (925) 583-8400 www.bridgelux.com At Bridgelux, we help companies, industries and people experience the power and possibility of light. Since 2002, we’ve designed LED solutions that are high performing, energy efficient, cost effective and easy to integrate. Our focus is on light’s impact on human behavior, deliver- ing products that create better environments, experiences and returns—both experiential and financial. And our patented technology drives new platforms for commercial and industrial luminaires. For more information about the company, please visit bridgelux.com twitter.com/Bridgelux facebook.com/Bridgelux youtube.com/user/Bridgelux linkedin.com/company/bridgelux-inc-_2 WeChat ID: BridgeluxInChina