Datasheet sections

The V Series™ LED Array products deliver high quality light in a compact and cost-effective solid-state lighting package. These chip on board (CoB) arrays can be efficiently driven up to three times the nominal drive current, enabling design flexibility not previously possible. These high flux density light sources are designed to support a wide range of high quality, low cost directional luminaires and replacement lamps for both interior and exterior commercial and residential applications. The V10 LED Array is available in a variety of electrical, CCT, and CRI combinations providing substantial design flexibility and energy efficiency advantages. Lighting system designs incorporating these LED arrays deliver increased system level efficacy and a longer service life. Typical applications include replacement lamps and task, accent, spot, track, wide area, security, wall packs and down lights. V Series

Features

  • Efficacy of 178 lm/W typical, 3000K 80 CRI
  • Reliable operation at up to 3x nominal current, 30% increase in maximum lumens per LES size
  • Wide selection of CCT options (2700K-6500K) with minimum 70, 80 and 90 CRI options
  • Uniform high-quality illumination
  • 2 and 3 SDCM binning options (2700K – 4000K)
  • Forward voltage bin codes and backside marking
  • Instant light with unlimited dimming
  • 5-Year warranty Benefits
  • Enables high efficiency lighting systems and lower operating costs
  • Supports the trend toward luminaire miniaturization and delivers enhanced optical control
  • Design flexibility for a broad range of lighting

applications

  • Clean white light without pixelation
  • Uniform consistent white light
  • Design flexibility for multi-source applications
  • Easy to use with daylight and motion sensors to increase energy savings
  • Design with confidence

The part number designation for Bridgelux V Series LED arrays is explained as follows: 1 2 3 4 5 6 7 8 9 10 11 – 12 – 13 14 Product Family CCT Bin Options 2 = 2 SDCM 3 = 3 SDCM 4 = 4 SDCM CRI C = 70 CRI min. E = 80 CRI min. G = 90 CRI min. H = 97 CRI typ. Array Configuration 22 = 2,200K 27 = 2,700K 30 = 3,000K 35 = 3,500K 40 = 4,000K 50 = 5,000K 57 = 5,700K 65 = 6,500K BXRE – 30 E 100 0 – C – 8 3 Color Targeting Designator 0 = Cold Targeted 1 = Hot Targeted C = Décor Series Showcase Target Gen. 8Nominal CCT Flux Indicator 100x = 1000 lm Bridgelux arrays are fully engineered devices that provide consistent thermal and optical performance on an engineered mechanical platform. The V Series arrays are the most compact chip-on-board devices across all of Bridgelux’s LED Array products. The arrays incorporate several features to simplify design integration and assembly. Please visit www.bridgelux.com for more information on the V Series family of products. Fully engineered substrate for consistent thermal, mechanical and optical properties Yellow phosphor Light Emitting Surface (LES) Note: Part number and lot codes are scribed on back of array Polarity symbols Solder Pads White ring around LES Case Temperature (Tc) Measurement Point Designed to comply with global safety standards for creepage and clearance distances

The following product configurations are available: Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25°C (lm) Minimum Pulsed Flux6,7 Tc = 25°C (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRE-22E1000-A-8X 2200 80 300 1110 996 33.5 10.1 110 BXRE-22E1000-B-8X 2200 80 200 781 701 34.2 6.8 114 BXRE-22E1000-C-8X 2200 80 300 1053 945 30.7 9.2 114 BXRE-22G1000-A-8X 2200 90 300 901 808 33.5 10.1 90 BXRE-22G1000-B-8X 2200 90 200 634 569 34.2 6.8 93 BXRE-22G1000-C-8X 2200 90 300 853 765 30.7 9.2 93 BXRE-24G1000-A-8x 2400 90 300 1211 1066 33.5 10.1 120 BXRE-24G1000-B-8x 2400 90 200 852 750 34.2 6.8 125 BXRE-24G1000-C-8x 2400 90 300 1149 1011 30.7 9.2 125 BXRE-24H1000-A-8x 2400 97 300 1054 928 33.5 10.1 105 BXRE-24H1000-B-8x 2400 97 200 741 652 34.2 6.8 108 BXRE-24H1000-C-8x 2400 97 300 1000 880 30.7 9.2 109 BXRE-27E1000-A-8x 2700 80 300 1628 1460 33.5 10.1 162 BXRE-27E1000-B-8x 2700 80 200 1145 1027 34.2 6.8 167 BXRE-27E1000-C-8x 2700 80 300 1544 1385 30.7 9.2 168 BXRE-27G1000-A-8x 2700 90 300 1343 1205 33.5 10.1 134 BXRE-27G1000-B-8x 2700 90 200 945 848 34.2 6.8 138 BXRE-27G1000-C-8x 2700 90 300 1274 1143 30.7 9.2 138 BXRE-27G10H0-A-8x 2700 90 300 1401 1257 33.5 10.1 139 BXRE-27G10H0-B-8x 2700 90 200 986 884 34.2 6.8 144 BXRE-27G10H0-C-8x 2700 90 300 1329 1192 30.7 9.2 144 BXRE-27H1000-A-8x 2700 97 300 1191 1068 33.5 10.1 118 BXRE-27H1000-B-8x 2700 97 200 838 752 34.2 6.8 122 BXRE-27H1000-C-8x 2700 97 300 1129 1013 30.7 9.2 123 BXRE-30C1001-A-8x 3000 70 300 1811 1624 33.5 10.1 180 BXRE-30C1001-B-8x 3000 70 200 1274 1143 34.2 6.8 186 BXRE-30C1001-C-8x 3000 70 300 1718 1541 30.7 9.2 187 BXRE-30E1000-A-8x 3000 80 300 1730 1552 33.5 10.1 172 BXRE-30E1000-B-8x 3000 80 200 1217 1092 34.2 6.8 178 BXRE-30E1000-C-8x 3000 80 300 1641 1472 30.7 9.2 178 BXRE-30G1000-A-8x 3000 90 300 1404 1259 33.5 10.1 140 BXRE-30G1000-B-8x 3000 90 200 988 886 34.2 6.8 144 BXRE-30G1000-C-8x 3000 90 300 1329 1192 30.7 9.2 144 BXRE-30G10H0-A-8x 3000 90 300 1471 1319 33.5 10.1 146 BXRE-30G10H0-B-8x 3000 90 200 1034 927 34.2 6.8 151 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Décor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, Minimum R9 value is 60 for 90 CRI products on 2700K/3000K/3500K and 4000K, it is 50 on 5000K/5700K and 6500K. But for the CRI90 H0 products (higher efficiency CRI90 version), minimum R9 value is 55 on 2700K/3000K/3500K and 4000K. Minimum R9 value for 97 CRI products is 93 on 2700K and 3000K,and it is 85 on 3500K /4000K/5000K and 5700K. Bridgelux maintains a ± 3 tolerance on R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal drive current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal drive current are guaranteed by 100% test.

Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (Continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25°C (lm) Minimum Pulsed Flux6,7 Tc = 25°C (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRE-30G10H0-C-8x 3000 90 300 1395 1251 30.7 9.2 151 BXRE-30H1000-A-8x 3000 97 300 1272 1141 33.5 10.1 127 BXRE-30H1000-B-8x 3000 97 200 895 803 34.2 6.8 131 BXRE-30H1000-C-8x 3000 97 300 1207 1083 30.7 9.2 131 BXRE-35E1000-A-8x 3500 80 300 1771 1589 33.5 10.1 176 BXRE-35E1000-B-8x 3500 80 200 1246 1118 34.2 6.8 182 BXRE-35E1000-C-8x 3500 80 300 1680 1507 30.7 9.2 182 BXRE-35G1000-A-8x 3500 90 300 1455 1305 33.5 10.1 145 BXRE-35G1000-B-8x 3500 90 200 1024 919 34.2 6.8 150 BXRE-35G1000-C-8x 3500 90 300 1380 1238 30.7 9.2 150 BXRE-35G10H0-A-8x 3500 90 300 1525 1372 33.5 10.1 152 BXRE-35G10H0-B-8x 3500 90 200 1073 966 34.2 6.8 157 BXRE-35G10H0-C-8x 3500 90 300 1446 1302 30.7 9.2 157 BXRE-35H1000-A-8x 3500 97 300 1307 1150 33.5 10.1 130 BXRE-35H1000-B-8x 3500 97 200 920 810 34.2 6.8 135 BXRE-35H1000-C-8x 3500 97 300 1240 1091 30.7 9.2 135 BXRE-40C1001-A-8x 4000 70 300 1862 1670 33.5 10.1 185 BXRE-40C1001-B-8x 4000 70 200 1310 1175 34.2 6.8 192 BXRE-40C1001-C-8x 4000 70 300 1766 1584 30.7 9.2 192 BXRE-40E1000-A-8x 4000 80 300 1781 1598 33.5 10.1 177 BXRE-40E1000-B-8x 4000 80 200 1253 1124 34.2 6.8 183 BXRE-40E1000-C-8x 4000 80 300 1689 1515 30.7 9.2 183 BXRE-40G1000-A-8x 4000 90 300 1486 1333 33.5 10.1 148 BXRE-40G1000-B-8x 4000 90 200 1045 937 34.2 6.8 153 BXRE-40G1000-C-8x 4000 90 300 1409 1264 30.7 9.2 153 BXRE-40G10H0-A-8x 4000 90 300 1540 1386 33.5 10.1 153 BXRE-40G10H0-B-8x 4000 90 200 1083 975 34.2 6.8 158 BXRE-40G10H0-C-8x 4000 90 300 1460 1314 30.7 9.2 159 BXRE-40H1000-A-8x 4000 97 300 1343 1182 33.5 10 134 BXRE-40H1000-B-8x 4000 97 200 945 848 34.2 6.8 138 BXRE-40H1000-C-8x 4000 97 300 1274 1143 30.7 9.2 138 BXRE-50C1001-A-8x 5000 70 300 1872 1679 33.5 10.1 186 BXRE-50C1001-B-8x 5000 70 200 1317 1181 34.2 6.8 193 BXRE-50C1001-C-8x 5000 70 300 1776 1593 30.7 9.2 193 BXRE-50E1001-A-8x 5000 80 300 1801 1615 33.5 10.1 179 BXRE-50E1001-B-8x 5000 80 200 1267 1136 34.2 6.8 185 BXRE-50E1001-C-8x 5000 80 300 1709 1533 30.7 9.2 186 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Décor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, Minimum R9 value is 60 for 90 CRI products on 2700K/3000K/3500K and 4000K, it is 50 on 5000K/5700K and 6500K. But for the CRI90 H0 products (higher efficiency CRI90 version), minimum R9 value is 55 on 2700K/3000K/3500K and 4000K. Minimum R9 value for 97 CRI products is 93 on 2700K and 3000K,and it is 85 on 3500K /4000K/5000K and 5700K. Bridgelux maintains a ± 3 tolerance on R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal drive current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal drive current are guaranteed by 100% test.

Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (Continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25°C (lm) Minimum Pulsed Flux6,7 Tc = 25°C (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRE-50G1001-A-8x 5000 90 300 1557 1397 33.5 10.1 155 BXRE-50G1001-B-8x 5000 90 200 1095 982 34.2 6.8 160 BXRE-50G1001-C-8x 5000 90 300 1477 1325 30.7 9.2 160 BXRE-57C1001-A-8x 5700 70 300 1822 1634 33.5 10.1 181 BXRE-57C1001-B-8x 5700 70 200 1281 1149 34.2 6.8 187 BXRE-57C1001-C-8x 5700 70 300 1728 1550 30.7 9.2 188 BXRE-57E1001-A-8x 5700 80 300 1730 1552 33.5 10.1 172 BXRE-57E1001-B-8x 5700 80 200 1217 1092 34.2 6.8 178 BXRE-57E1001-C-8x 5700 80 300 1641 1472 30.7 9.2 178 BXRE-65C1001-A-8x 6500 70 300 1822 1634 33.5 10.1 181 BXRE-65C1001-B-8x 6500 70 200 1281 1149 34.2 6.8 187 BXRE-65C1001-C-8x 6500 70 300 1728 1550 30.7 9.2 188 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Décor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, Minimum R9 value is 60 for 90 CRI products on 2700K/3000K/3500K and 4000K, it is 50 on 5000K/5700K and 6500K. But for the CRI90 H0 products (higher efficiency CRI90 version), minimum R9 value is 55 on 2700K/3000K/3500K and 4000K. Minimum R9 value for 97 CRI products is 93 on 2700K and 3000K,and it is 85 on 3500K /4000K/5000K and 5700K. Bridgelux maintains a ± 3 tolerance on R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal drive current are guaranteed by 100% test.

Table 2: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85°C (lm) Minimum DC Flux6 Tc = 85°C (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRE-22E1000-A-8X 2200 80 300 999 897 32.9 9.9 101 BXRE-22E1000-B-8X 2200 80 200 703 631 33.6 6.7 105 BXRE-22E1000-C-8X 2200 80 300 948 851 30.1 9.0 105 BXRE-22G1000-A-8X 2200 90 300 811 728 32.9 9.9 82 BXRE-22G1000-B-8X 2200 90 200 571 512 33.6 6.7 85 BXRE-22G1000-C-8X 2200 90 300 767 689 30.1 9.0 85 BXRE-24G1000-A-8x 2400 90 300 1090 959 32.9 9.9 110 BXRE-24G1000-B-8x 2400 90 200 767 675 33.6 6.7 114 BXRE-24G1000-C-8x 2400 90 300 1034 910 30.1 9.0 114 BXRE-24H1000-A-8x 2400 97 300 949 835 32.9 9.9 96 BXRE-24H1000-B-8x 2400 97 200 667 587 33.6 6.7 99 BXRE-24H1000-C-8x 2400 97 300 900 792 30.1 9.0 100 BXRE-27E1000-A-8x 2700 80 300 1465 1316 32.9 9.9 148 BXRE-27E1000-B-8x 2700 80 200 1031 925 33.6 6.7 154 BXRE-27E1000-C-8x 2700 80 300 1390 1248 30.1 9.0 154 BXRE-27G1000-A-8x 2700 90 300 1209 1085 32.9 9.9 122 BXRE-27G1000-B-8x 2700 90 200 850 764 33.6 6.7 127 BXRE-27G1000-C-8x 2700 90 300 1147 1030 30.1 9.0 127 BXRE-27G10H0-A-8x 2700 90 300 1261 1132 32.9 9.9 128 BXRE-27G10H0-B-8x 2700 90 200 887 797 33.6 6.7 132 BXRE-27G10H0-C-8x 2700 90 300 1196 1074 30.1 9.0 132 BXRE-27H1000-A-8x 2700 97 300 1072 963 32.9 9.9 109 BXRE-27H1000-B-8x 2700 97 200 754 677 33.6 6.7 112 BXRE-27H1000-C-8x 2700 97 300 1016 912 30.1 9.0 112 BXRE-30C1001-A-8x 3000 70 300 1630 1464 32.9 9.9 165 BXRE-30C1001-B-8x 3000 70 200 1147 1030 33.6 6.7 171 BXRE-30C1001-C-8x 3000 70 300 1546 1388 30.1 9.0 171 BXRE-30E1000-A-8x 3000 80 300 1557 1398 32.9 9.9 158 BXRE-30E1000-B-8x 3000 80 200 1095 984 33.6 6.7 163 BXRE-30E1000-C-8x 3000 80 300 1477 1326 30.1 9.0 163 BXRE-30G1000-A-8x 3000 90 300 1264 1135 32.9 9.9 128 BXRE-30G1000-B-8x 3000 90 200 889 799 33.6 6.7 133 BXRE-30G1000-C-8x 3000 90 300 1196 1074 30.1 9.0 132 BXRE-30G10H0-A-8x 3000 90 300 1323 1189 32.9 9.9 134 BXRE-30G10H0-B-8x 3000 90 200 931 836 33.6 6.7 139 Notes for Table 2 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Décor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, Minimum R9 value is 60 for 90 CRI products on 2700K/3000K/3500K and 4000K, it is 50 on 5000K/5700K and 6500K. But for the CRI90 H0 products (higher efficiency CRI90 version), minimum R9 value is 55 on 2700K/3000K/3500K and 4000K. Minimum R9 value for 97 CRI products is 93 on 2700K and 3000K,and it is 85 on 3500K /4000K/5000K and 5700K. Bridgelux maintains a ± 3 tolerance on R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.

Table 2: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85°C (lm) Minimum DC Flux6 Tc = 85°C (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRE-30G10H0-C-8x 3000 90 300 1255 1127 30.1 9.0 139 BXRE-30H1000-A-8x 3000 97 300 1145 1028 32.9 9.9 116 BXRE-30H1000-B-8x 3000 97 200 805 723 33.6 6.7 120 BXRE-30H1000-C-8x 3000 97 300 1086 975 30.1 9.0 120 BXRE-35E1000-A-8x 3500 80 300 1594 1431 32.9 9.9 161 BXRE-35E1000-B-8x 3500 80 200 1121 1007 33.6 6.7 167 BXRE-35E1000-C-8x 3500 80 300 1512 1358 30.1 9.0 167 BXRE-35G1000-A-8x 3500 90 300 1310 1176 32.9 9.9 133 BXRE-35G1000-B-8x 3500 90 200 921 828 33.6 6.7 137 BXRE-35G1000-C-8x 3500 90 300 1242 1115 30.1 9.0 137 BXRE-35G10H0-A-8x 3500 90 300 1372 1235 32.9 9.9 139 BXRE-35G10H0-B-8x 3500 90 200 966 869 33.6 6.7 144 BXRE-35G10H0-C-8x 3500 90 300 1302 1171 30.1 9.0 144 BXRE-35H1000-A-8x 3500 97 300 1177 1036 32.9 9.9 119 BXRE-35H1000-B-8x 3500 97 200 828 728 33.6 6.7 123 BXRE-35H1000-C-8x 3500 97 300 1116 982 30.1 9.0 124 BXRE-40C1001-A-8x 4000 70 300 1676 1505 32.9 9.9 170 BXRE-40C1001-B-8x 4000 70 200 1179 1059 33.6 6.7 176 BXRE-40C1001-C-8x 4000 70 300 1590 1427 30.1 9.0 176 BXRE-40E1000-A-8x 4000 80 300 1603 1439 32.9 9.9 162 BXRE-40E1000-B-8x 4000 80 200 1128 1013 33.6 6.7 168 BXRE-40E1000-C-8x 4000 80 300 1520 1365 30.1 9.0 168 BXRE-40G1000-A-8x 4000 90 300 1337 1201 32.9 9.9 135 BXRE-40G1000-B-8x 4000 90 200 941 845 33.6 6.7 140 BXRE-40G1000-C-8x 4000 90 300 1268 1139 30.1 9.0 140 BXRE-40G10H0-A-8x 4000 90 300 1386 1247 32.9 9.9 140 BXRE-40G10H0-B-8x 4000 90 200 975 877 33.6 6.7 145 BXRE-40G10H0-C-8x 4000 90 300 1314 1183 30.1 9.0 146 BXRE-40H1000-A-8x 4000 97 300 1209 1064 32.9 10 122 BXRE-40H1000-B-8x 4000 97 200 851 764 33.6 6.7 127 BXRE-40H1000-C-8x 4000 97 300 1147 1030 30.1 9.0 127 BXRE-50C1001-A-8x 5000 70 300 1685 1513 32.9 9.9 171 BXRE-50C1001-B-8x 5000 70 200 1186 1064 33.6 6.7 177 BXRE-50C1001-C-8x 5000 70 300 1599 1435 30.1 9.0 177 Notes for Table 2: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Décor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, Minimum R9 value is 60 for 90 CRI products on 2700K/3000K/3500K and 4000K, it is 50 on 5000K/5700K and 6500K. But for the CRI90 H0 products (higher efficiency CRI90 version), minimum R9 value is 55 on 2700K/3000K/3500K and 4000K. Minimum R9 value for 97 CRI products is 93 on 2700K and 3000K,and it is 85 on 3500K /4000K/5000K and 5700K. Bridgelux maintains a ± 3 tolerance on R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.

Table 2: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85°C (lm) Minimum DC Flux6 Tc = 85°C (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRE-50E1001-A-8x 5000 80 300 1621 1456 32.9 9.9 164 BXRE-50E1001-B-8x 5000 80 200 1140 1024 33.6 6.7 170 BXRE-50E1001-C-8x 5000 80 300 1538 1381 30.1 9.0 170 BXRE-50G1001-A-8x 5000 90 300 1401 1258 32.9 9.9 142 BXRE-50G1001-B-8x 5000 90 200 986 885 33.6 6.7 147 BXRE-50G1001-C-8x 5000 90 300 1329 1194 30.1 9.0 147 BXRE-57C1001-A-8x 5700 70 300 1639 1473 32.9 9.9 166 BXRE-57C1001-B-8x 5700 70 200 1153 1035 33.6 6.7 172 BXRE-57C1001-C-8x 5700 70 300 1555 1397 30.1 9.0 172 BXRE-57E1001-A-8x 5700 80 300 1557 1398 32.9 9.9 158 BXRE-57E1001-B-8x 5700 80 200 1095 984 33.6 6.7 163 BXRE-57E1001-C-8x 5700 80 300 1477 1326 30.1 9.0 163 BXRE-65C1001-A-8x 6500 70 300 1639 1473 32.9 9.9 166 BXRE-65C1001-B-8x 6500 70 200 1153 1035 33.6 6.7 172 BXRE-65C1001-C-8x 6500 70 300 1555 1397 30.1 9.0 172 BXRE-65E1001-A-8x 6500 80 300 1575 1414 32.9 9.9 160 BXRE-65E1001-B-8x 6500 80 200 1108 995 33.6 6.7 165 BXRE-65E1001-C-8x 6500 80 300 1494 1315 30.1 9.0 165 Notes for Table 2: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Décor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, Minimum R9 value is 60 for 90 CRI products on 2700K/3000K/3500K and 4000K, it is 50 on 5000K/5700K and 6500K. But for the CRI90 H0 products (higher efficiency CRI90 version), minimum R9 value is 55 on 2700K/3000K/3500K and 4000K. Minimum R9 value for 97 CRI products is 93 on 2700K and 3000K,and it is 85 on 3500K /4000K/5000K and 5700K. Bridgelux maintains a ± 3 tolerance on R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.

European Product Registry for Energy Labeling The European Product Registry for Energy Labeling (EPREL) is defined in the EU Regulation 2017/1369 to provide import- ant energy efficiency information to consumers. Together with Energy Labeling Regulation ELR (EU) 2019/2015 which was amended by regulation (EU) 2021/340 for energy labelling of light sources, manufacturers are required to declare an ener- gy class based on key technical specifications from each of their product and register it in an open data base managed by EPREL It is now a legal requirement for a vendor of light sources to upload information about their products into the EPREL database before placing these products on the market in the EU. Table 3 below provides a list of part numbers that are in compliance with ELR and are currently listed in the EPREL data- base. At Bridgelux, we are fully committed to supplying products that are compliant with pertinent laws, rules, and obligation imposed by relevant government bodies including the European Energy Labeling regulation. Customers can use these products with full confidence for any projects that fall under the ELR. Table 3: Part numbers registered in European Product Registry for Energy Labeling PART NUMBER1 CCT (K) CRI Current2 (mA) Vf (V) Useful flux3 (Φuse) at 85C (lm) Pow- er (W) Efficacy (lm/W) Energy efficiency class4 Regis- tration No URL to Product Information Sheet in EPREL Database Notes for Table 3: 1. All device listed here must be disposed as e-waste upon its end of life according to local country guideline in each country. 2. For information on performance values at alternative drive conditions. please refer to the Product Selection Guide, Absolute Maximum Rating Table and Performance Curves in this data sheet. 3. For a definition of useful luminous flux (ΦΦuse), please see the ELR regulations at https:/ /tinyurl.com/4b6zvt4m. 4. EPREL requires an arrow symbol containing the letter of the energy efficiency class to be displayed. on technical promotional material. Refer to this energy efficiency class column for specific energy efficiency class on each part number.

European Product Registry for Energy Labeling Table 3: Part numbers registered in European Product Registry for Energy Labeling (Continued) PART NUMBER1 CCT (K) CRI Current2 (mA) Vf (V) Useful flux3 (Φuse) at 85C (lm) Pow- er (W) Efficacy (lm/W) Energy efficiency class4 Regis- tration No URL to Product Information Sheet in EPREL Database BXRE-35H1000-A-83 3500 95 740 35.2 2706 26 104 F 2366245 https:/ /eprel.ec.europa.eu/qr/2366245 BXRE-35H1000-B-83 3500 95 500 36.8 1865 18 101 F 2366246 https:/ /eprel.ec.europa.eu/qr/2366246 BXRE-35H1000-C-83 3500 95 780 33.2 2685 26 104 F 2366247 https:/ /eprel.ec.europa.eu/qr/2366247 Notes for Table 3: 1. All device listed here must be disposed as e-waste upon its end of life according to local country guideline in each country. 2. For information on performance values at alternative drive conditions. please refer to the Product Selection Guide, Absolute Maximum Rating Table and Performance Curves in this data sheet. 3. For a definition of useful luminous flux (ΦΦuse), please see the ELR regulations at https:/ /tinyurl.com/4b6zvt4m. 4. EPREL requires an arrow symbol containing the letter of the energy efficiency class to be displayed. on technical promotional material. Refer to this energy efficiency class column for specific energy efficiency class on each part number.

European Product Registry for Energy Labeling Table 3: Part numbers registered in European Product Registry for Energy Labeling (Continued) PART NUMBER1 CCT (K) CRI Current2 (mA) Vf (V) Useful flux3 (Φuse) at 85C (lm) Pow- er (W) Efficacy (lm/W) Energy efficiency class4 Regis- tration No URL to Product Information Sheet in EPREL Database Notes for Table 3: 1. All device listed here must be disposed as e-waste upon its end of life according to local country guideline in each country. 2. For information on performance values at alternative drive conditions. please refer to the Product Selection Guide, Absolute Maximum Rating Table and Performance Curves in this data sheet. 3. For a definition of useful luminous flux (ΦΦuse), please see the ELR regulations at https:/ /tinyurl.com/4b6zvt4m. 4. EPREL requires an arrow symbol containing the letter of the energy efficiency class to be displayed. on technical promotional material. Refer to this energy efficiency class column for specific energy efficiency class on each part number.

Performance at Commonly Used Drive Currents V Series LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. V Series LED Arrays may also be driven at other drive currents dependent on specific application design requirements. The performance at any drive current can be derived from the current vs. voltage characteristics shown in Figures 1, 2 & 3 and the flux vs. current characteristics shown in Figures 4, 5 & 6. The performance at commonly used drive currents is summarized in Table 4. Table 4: Product Performance at Commonly Used Drive Currents Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25°C (V) Typical Power Tc = 25°C (W) Typical Flux2 Tc = 25°C (lm) Typical DC Flux3 Tc = 85°C (lm) Typical Efficacy Tc = 25°C (lm/W) BXRE-22E1000-A-8X 80 150 32.5 4.9 581 523 119 225 33.0 7.4 848 763 115 300 33.5 10.1 1110 999 110 360 33.9 12.2 1315 1184 108 600 35.3 21.2 2101 1891 99 960 37.2 35.7 3175 2857 89 BXRE-22E1000-B-8X 80 100 32.9 3.3 407 366 123 150 33.6 5.0 594 535 119 200 34.2 6.8 781 703 115 270 35.0 9.5 1023 920 108 400 36.5 14.6 1453 1307 99 500 37.5 18.7 1759 1583 94 BXRE-22E1000-C-8X 80 150 29.8 4.5 552 497 123 225 30.3 6.8 805 724 118 300 30.7 9.2 1053 948 114 360 31.1 11.2 1247 1123 111 600 32.4 19.4 1993 1794 103 1000 34.3 34.3 3117 2805 91 BXRE-22G1000-A-8X 90 150 32.5 4.9 472 425 96 225 33.0 7.4 688 620 93 300 33.5 10.1 901 811 89 360 33.9 12.2 1068 961 88 600 35.3 21.2 1705 1535 80 960 37.2 35.7 2577 2319 72 BXRE-22G1000-B-8X 90 100 32.9 3.3 330 297 100 150 33.6 5.0 482 434 96 200 34.2 6.8 634 571 93 270 35.0 9.5 830 747 87 400 36.5 14.6 1179 1061 81 500 37.5 18.7 1428 1285 76 BXRE-22G1000-C-8X 90 150 29.8 4.5 447 402 99 225 30.3 6.8 652 587 96 300 30.7 9.2 853 767 93 360 31.1 11.2 1011 909 90 600 32.4 19.4 1614 1453 83 1000 34.3 34.3 2525 2272 74 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25°C (V) Typical Power Tc = 25°C (W) Typical Flux2 Tc = 25°C (lm) Typical DC Flux3 Tc = 85°C (lm) Typical Efficacy Tc = 25°C (lm/W) BXRE-24G1000-A-8x 90 150 32.5 4.9 634 571 130 225 33.0 7.4 926 833 125 300 33.5 10.1 1211 1090 120 360 33.9 12.2 1435 1291 118 600 35.3 21.2 2292 2063 108 960 37.2 35.7 3463 3117 97 BXRE-24G1000-B-8x 90 100 32.9 3.3 444 400 135 150 33.6 5.0 648 584 129 200 34.2 6.8 852 767 125 270 35.0 9.5 1116 1004 118 400 36.5 14.6 1585 1427 109 500 37.5 18.7 1920 1728 102 BXRE-24G1000-C-8x 90 150 29.8 4.5 602 542 134 225 30.3 6.8 878 790 129 300 30.7 9.2 1149 1034 125 360 31.1 11.2 1361 1225 122 600 32.4 19.4 2174 1957 112 1000 34.3 34.3 3400 3060 99 BXRE-24H1000-A-8x 97 150 32.5 4.9 552 497 113 225 33 7.4 806 725 109 300 33.5 10.1 1054 949 105 360 33.9 12.2 1249 1124 102 600 35.3 21.2 1995 1796 94 960 37.2 35.7 3015 2714 84 BXRE-24H1000-B-8x 97 100 32.9 3.3 386 348 117 150 33.6 5.0 564 508 112 200 34.2 6.8 741 667 108 270 35 9.5 971 874 103 400 36.5 14.6 1379 1241 94 500 37.5 18.8 1670 1503 89 BXRE-24H1000-C-8x 97 150 29.8 4.5 524 472 117 225 30.3 6.8 765 688 112 300 30.7 9.2 1000 900 109 360 31.1 11.2 1185 1067 106 600 32.4 19.4 1894 1704 97 1000 34.3 34.3 2961 2665 86 BXRE-27E1000-A-8x 80 150 32.5 4.9 853 768 175 225 33 7.4 1245 1120 168 300 33.5 10.1 1628 1465 162 360 33.9 12.2 1929 1736 158 600 35.3 21.2 3082 2774 145 960 37.2 35.7 4657 4191 130 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Table 4: Product Performance at Commonly Used Drive Currents (Continued) Performance at Commonly Used Drive Currents Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25°C (V) Typical Power Tc = 25°C (W) Typical Flux2 Tc = 25°C (lm) Typical DC Flux3 Tc = 85°C (lm) Typical Efficacy Tc = 25°C (lm/W) BXRE-27E1000-B-8x 80 100 32.9 3.3 597 537 181 150 33.6 5 872 785 173 200 34.2 6.8 1145 1031 168 270 35 9.5 1500 1350 159 400 36.5 14.6 2131 1918 146 500 37.5 18.7 2581 2323 138 BXRE-27E1000-C-8x 80 150 29.8 4.5 809 728 181 225 30.3 6.8 1181 1063 173 300 30.7 9.2 1544 1390 168 360 31.1 11.2 1830 1647 164 600 32.4 19.4 2924 2631 150 1000 34.3 34.3 4572 4115 133 BXRE-27G1000-A-8x 90 150 32.5 4.9 704 633 144 225 33 7.4 1027 924 138 300 33.5 10.1 1343 1209 134 360 33.9 12.2 1592 1433 130 600 35.3 21.2 2543 2288 120 960 37.2 35.7 3842 3458 107 BXRE-27G1000-B-8x 90 100 32.9 3.3 493 443 150 150 33.6 5 719 647 143 200 34.2 6.8 945 850 138 270 35 9.5 1238 1114 131 400 36.5 14.6 1758 1582 120 500 37.5 18.7 2129 1917 114 BXRE-27G1000-C-8x 90 150 29.8 4.5 668 601 149 225 30.3 6.8 974 877 143 300 30.7 9.2 1274 1147 138 360 31.1 11.2 1510 1359 135 600 32.4 19.4 2412 2171 124 1000 34.3 34.3 3772 3395 110 BXRE-27G10H0-A-8x 90 150 32.5 4.9 734 661 151 225 33 7.4 1071 964 144 300 33.5 10.1 1401 1261 139 360 33.9 12.2 1660 1494 136 600 35.3 21.2 2653 2387 125 960 37.2 35.7 4008 3607 112 BXRE-27G10H0-B-8x 90 100 32.9 3.3 514 462 156 150 33.6 5 750 675 149 200 34.2 6.8 986 887 144 270 35 9.5 1291 1162 137 400 36.5 14.6 1834 1651 126 500 37.5 18.7 2221 1999 118 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25°C (V) Typical Power Tc = 25°C (W) Typical Flux2 Tc = 25°C (lm) Typical DC Flux3 Tc = 85°C (lm) Typical Efficacy Tc = 25°C (lm/W) BXRE-27G10H0-C-8x 90 150 29.8 4.5 696 627 156 225 30.3 6.8 1016 914 149 300 30.7 9.2 1329 1196 144 360 31.1 11.2 1575 1417 141 600 32.4 19.4 2516 2264 129 1000 34.3 34.3 3935 3541 115 BXRE-27H1000-A-8x 97 150 32.5 4.9 624 561 128 225 33 7.4 910 819 123 300 33.5 10.1 1191 1072 118 360 33.9 12.2 1411 1270 116 600 35.3 21.2 2254 2028 106 960 37.2 35.7 3405 3065 95 BXRE-27H1000-B-8x 97 100 32.9 3.3 437 393 133 150 33.6 5 638 574 127 200 34.2 6.8 838 754 122 270 35 9.5 1097 987 116 400 36.5 14.6 1558 1403 107 500 37.5 18.7 1887 1699 101 BXRE-27H1000-C-8x 97 150 29.8 4.5 592 532 132 225 30.3 6.8 863 777 127 300 30.7 9.2 1129 1016 122 360 31.1 11.2 1338 1204 120 600 32.4 19.4 2138 1924 110 1000 34.3 34.3 3343 3009 97 BXRE-30C1001-A-8x 70 150 32.5 4.9 949 854 195 225 33 7.4 1385 1246 186 300 33.5 10.1 1811 1630 180 360 33.9 12.2 2146 1932 176 600 35.3 21.2 3429 3086 162 960 37.2 35.7 5180 4662 145 BXRE-30C1001-B-8x 70 100 32.9 3.3 664 598 202 150 33.6 5 970 873 193 200 34.2 6.8 1274 1147 186 270 35 9.5 1669 1502 176 400 36.5 14.6 2371 2134 162 500 37.5 18.7 2872 2584 153 BXRE-30C1001-C-8x 70 150 29.8 4.5 900 810 201 225 30.3 6.8 1313 1182 193 300 30.7 9.2 1718 1546 186 360 31.1 11.2 2036 1832 182 600 32.4 19.4 3252 2927 167 1000 34.3 34.3 5086 4578 148 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25°C (V) Typical Power Tc = 25°C (W) Typical Flux2 Tc = 25°C (lm) Typical DC Flux3 Tc = 85°C (lm) Typical Efficacy Tc = 25°C (lm/W) BXRE-30E1000-A-8x 80 150 32.5 4.9 906 816 186 225 33 7.4 1322 1190 178 300 33.5 10.1 1730 1557 172 360 33.9 12.2 2050 1845 168 600 35.3 21.2 3275 2947 155 960 37.2 35.7 4948 4453 138 BXRE-30E1000-B-8x 80 100 32.9 3.3 634 571 193 150 33.6 5 926 834 184 200 34.2 6.8 1217 1095 178 270 35 9.5 1594 1435 169 400 36.5 14.6 2264 2038 155 500 37.5 18.7 2742 2468 146 BXRE-30E1000-C-8x 80 150 29.8 4.5 860 774 192 225 30.3 6.8 1254 1129 184 300 30.7 9.2 1641 1477 178 360 31.1 11.2 1944 1750 174 600 32.4 19.4 3106 2796 160 1000 34.3 34.3 4858 4372 141 BXRE-30G1000-A-8x 90 150 32.5 4.9 736 662 151 225 33 7.4 1073 966 145 300 33.5 10.1 1404 1264 140 360 33.9 12.2 1664 1498 136 600 35.3 21.2 2658 2392 125 960 37.2 35.7 4016 3615 112 BXRE-30G1000-B-8x 90 100 32.9 3.3 515 463 157 150 33.6 5 752 677 149 200 34.2 6.8 988 889 144 270 35 9.5 1294 1165 137 400 36.5 14.6 1838 1654 126 500 37.5 18.7 2226 2004 119 BXRE-30G1000-C-8x 90 150 29.8 4.5 696 627 156 225 30.3 6.8 1016 914 149 300 30.7 9.2 1329 1196 144 360 31.1 11.2 1575 1417 141 600 32.4 19.4 2516 2264 129 1000 34.3 34.3 3935 3541 115 BXRE-30G10H0-A-8x 90 150 32.5 4.9 770 693 158 225 33 7.4 1124 1012 151 300 33.5 10.1 1471 1323 146 360 33.9 12.2 1742 1568 143 600 35.3 21.2 2784 2505 131 960 37.2 35.7 4205 3785 118 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25°C (V) Typical Power Tc = 25°C (W) Typical Flux2 Tc = 25°C (lm) Typical DC Flux3 Tc = 85°C (lm) Typical Efficacy Tc = 25°C (lm/W) BXRE-30G10H0-B-8x 90 100 32.9 3.3 539 485 164 150 33.6 5 787 709 156 200 34.2 6.8 1034 931 151 270 35 9.5 1355 1219 143 400 36.5 14.6 1925 1732 132 500 37.5 18.7 2331 2098 124 BXRE-30G10H0-C-8x 90 150 29.8 4.5 731 658 163 225 30.3 6.8 1066 960 156 300 30.7 9.2 1395 1255 151 360 31.1 11.2 1653 1487 148 600 32.4 19.4 2640 2376 136 1000 34.3 34.3 4129 3716 120 BXRE-30H1000-A-8x 97 150 32.5 4.9 666 600 137 225 33 7.4 972 875 131 300 33.5 10.1 1272 1145 127 360 33.9 12.2 1507 1357 124 600 35.3 21.2 2408 2167 114 960 37.2 35.7 3638 3274 102 BXRE-30H1000-B-8x 97 100 32.9 3.3 466 420 142 150 33.6 5 681 613 135 200 34.2 6.8 895 805 131 270 35 9.5 1172 1055 124 400 36.5 14.6 1665 1498 114 500 37.5 18.7 2017 1815 108 BXRE-30H1000-C-8x 97 150 29.8 4.5 632 569 141 225 30.3 6.8 922 830 135 300 30.7 9.2 1207 1086 131 360 31.1 11.2 1430 1287 128 600 32.4 19.4 2284 2056 117 1000 34.3 34.3 3572 3215 104 BXRE-35E1000-A-8x 80 150 32.5 4.9 928 835 190 225 33 7.4 1354 1218 182 300 33.5 10.1 1771 1594 176 360 33.9 12.2 2098 1888 172 600 35.3 21.2 3352 3017 158 960 37.2 35.7 5064 4558 142 BXRE-35E1000-B-8x 80 100 32.9 3.3 649 584 197 150 33.6 5 948 853 188 200 34.2 6.8 1246 1121 182 270 35 9.5 1632 1468 172 400 36.5 14.6 2318 2086 159 500 37.5 18.7 2807 2526 150 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25°C (V) Typical Power Tc = 25°C (W) Typical Flux2 Tc = 25°C (lm) Typical DC Flux3 Tc = 85°C (lm) Typical Efficacy Tc = 25°C (lm/W) BXRE-35E1000-C-8x 80 150 29.8 4.5 880 792 197 225 30.3 6.8 1284 1156 188 300 30.7 9.2 1680 1512 182 360 31.1 11.2 1990 1791 178 600 32.4 19.4 3179 2861 164 1000 34.3 34.3 4972 4475 145 BXRE-35G1000-A-8x 90 150 32.5 4.9 762 686 156 225 33 7.4 1112 1001 150 300 33.5 10.1 1455 1310 145 360 33.9 12.2 1724 1552 141 600 35.3 21.2 2755 2479 130 960 37.2 35.7 4162 3746 116 BXRE-35G1000-B-8x 90 100 32.9 3.3 534 480 162 150 33.6 5 779 701 155 200 34.2 6.8 1024 921 150 270 35 9.5 1341 1207 142 400 36.5 14.6 1905 1714 131 500 37.5 18.7 2307 2076 123 BXRE-35G1000-C-8x 90 150 29.8 4.5 723 651 162 225 30.3 6.8 1055 950 155 300 30.7 9.2 1380 1242 150 360 31.1 11.2 1636 1472 146 600 32.4 19.4 2613 2352 134 1000 34.3 34.3 4086 3678 119 BXRE-35G10H0-A-8x 90 150 32.5 4.9 799 719 164 225 33 7.4 1166 1050 157 300 33.5 10.1 1525 1372 152 360 33.9 12.2 1807 1626 148 600 35.3 21.2 2887 2598 136 960 37.2 35.7 4362 3926 122 BXRE-35G10H0-B-8x 90 100 32.9 3.3 559 504 170 150 33.6 5.0 817 735 162 200 34.2 6.8 1073 966 157 270 35 9.5 1406 1265 149 400 36.5 14.6 1997 1797 137 500 37.5 18.8 2419 2177 129 BXRE-35G10H0-C-8x 90 150 29.8 4.5 758 682 169 225 30.3 6.8 1106 995 162 300 30.7 9.2 1446 1302 157 360 31.1 11.2 1714 1542 153 600 32.4 19.4 2738 2465 141 1000 34.3 34.3 4282 3854 125 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25°C (V) Typical Power Tc = 25°C (W) Typical Flux2 Tc = 25°C (lm) Typical DC Flux3 Tc = 85°C (lm) Typical Efficacy Tc = 25°C (lm/W) BXRE-35H1000-A-8x 97 150 32.5 4.9 685 616 140 225 33 7.4 999 899 135 300 33.5 10.1 1307 1177 130 360 33.9 12.2 1549 1394 127 600 35.3 21.2 2475 2227 117 960 37.2 35.7 3740 3366 105 BXRE-35H1000-B-8x 97 100 32.9 3.3 480 431 145 150 33.6 5 700 630 140 200 34.2 6.8 920 828 135 270 35 9.5 1205 1084 127 400 36.5 14.6 1712 1540 117 500 37.5 18.7 2073 1865 111 BXRE-35H1000-C-8x 97 150 29.8 4.5 650 585 144 225 30.3 6.8 948 854 139 300 30.7 9.2 1240 1116 135 360 31.1 11.2 1470 1323 131 600 32.4 19.4 2348 2113 121 1000 34.3 34.3 3671 3305 107 BXRE-40C1001-A-8x 70 150 32.5 4.9 976 878 200 225 33 7.4 1424 1281 192 300 33.5 10.1 1862 1676 185 360 33.9 12.2 2207 1986 181 600 35.3 21.2 3525 3173 166 960 37.2 35.7 5326 4793 149 BXRE-40C1001-B-8x 70 100 32.9 3.3 683 615 208 150 33.6 5 997 898 198 200 34.2 6.8 1310 1179 192 270 35 9.5 1716 1544 181 400 36.5 14.6 2437 2194 167 500 37.5 18.7 2952 2657 157 BXRE-40C1001-C-8x 70 150 29.8 4.5 925 833 207 225 30.3 6.8 1350 1215 198 300 30.7 9.2 1766 1590 192 360 31.1 11.2 2093 1884 187 600 32.4 19.4 3344 3009 172 1000 34.3 34.3 5229 4706 152 BXRE-40E1000-A-8x 80 150 32.5 4.9 933 840 191 225 33 7.4 1361 1225 183 300 33.5 10.1 1781 1603 177 360 33.9 12.2 2110 1899 173 600 35.3 21.2 3371 3034 159 960 37.2 35.7 5093 4584 142 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25°C (V) Typical Power Tc = 25°C (W) Typical Flux2 Tc = 25°C (lm) Typical DC Flux3 Tc = 85°C (lm) Typical Efficacy Tc = 25°C (lm/W) BXRE-40E1000-B-8x 80 100 32.9 3.3 653 588 198 150 33.6 5 954 858 189 200 34.2 6.8 1253 1128 183 270 35 9.5 1641 1477 173 400 36.5 14.6 2331 2098 160 500 37.5 18.7 2823 2541 151 BXRE-40E1000-C-8x 80 150 29.8 4.5 885 796 198 225 30.3 6.8 1291 1162 189 300 30.7 9.2 1689 1520 183 360 31.1 11.2 2002 1801 179 600 32.4 19.4 3198 2878 164 1000 34.3 34.3 5001 4501 146 BXRE-40G1000-A-8x 90 150 32.5 4.9 778 701 160 225 33 7.4 1136 1022 153 300 33.5 10.1 1486 1337 148 360 33.9 12.2 1761 1584 144 600 35.3 21.2 2812 2531 133 960 37.2 35.7 4249 3824 119 BXRE-40G1000-B-8x 90 100 32.9 3.3 545 490 166 150 33.6 5 796 716 158 200 34.2 6.8 1045 941 153 270 35 9.5 1369 1232 145 400 36.5 14.6 1945 1750 133 500 37.5 18.7 2355 2120 126 BXRE-40G1000-C-8x 90 150 29.8 4.5 738 664 165 225 30.3 6.8 1077 970 158 300 30.7 9.2 1409 1268 153 360 31.1 11.2 1670 1503 149 600 32.4 19.4 2668 2401 137 1000 34.3 34.3 4172 3755 121 BXRE-40G10H0-A-8x 90 150 32.5 4.9 807 726 166 225 33 7.4 1178 1060 159 300 33.5 10.1 1540 1386 153 360 33.9 12.2 1825 1642 150 600 35.3 21.2 2915 2624 138 960 37.2 35.7 4405 3965 123 BXRE-40G10H0-B-8x 90 100 32.9 3.3 565 508 172 150 33.6 5.0 825 742 164 200 34.2 6.8 1083 975 158 270 35 9.5 1419 1277 150 400 36.5 14.6 2016 1814 138 500 37.5 18.8 2441 2197 130 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25°C (V) Typical Power Tc = 25°C (W) Typical Flux2 Tc = 25°C (lm) Typical DC Flux3 Tc = 85°C (lm) Typical Efficacy Tc = 25°C (lm/W) BXRE-40G10H0-C-8x 90 150 29.8 4.5 765 688 171 225 30.3 6.8 1117 1005 164 300 30.7 9.2 1460 1314 159 360 31.1 11.2 1730 1557 155 600 32.4 19.4 2765 2488 142 1000 34.3 34.3 4323 3891 126 BXRE-40H1000-A-8x 97 150 32.5 4.9 704 633 144 225 33 7.4 1027 924 138 300 33.5 10.1 1343 1209 134 360 33.9 12.2 1591 1432 130 600 35.3 21.2 2542 2288 120 960 37.2 35.7 3842 3458 108 BXRE-40H1000-B-8x 97 100 32.9 3.3 492 443 149 150 33.6 5 719 647 144 200 34.2 6.8 945 851 139 270 35 9.5 1238 1114 130 400 36.5 14.6 1758 1582 120 500 37.5 18.7 2129 1916 114 BXRE-40H1000-C-8x 97 150 29.8 4.5 668 601 148 225 30.3 6.8 974 876 143 300 30.7 9.2 1274 1147 138 360 31.1 11.2 1509 1358 135 600 32.4 19.4 2411 2170 124 1000 34.3 34.3 3772 3394 110 BXRE-50C1001-A-8x 70 150 32.5 4.9 981 883 201 225 33 7.4 1431 1288 193 300 33.5 10.1 1872 1685 186 360 33.9 12.2 2219 1997 182 600 35.3 21.2 3544 3190 167 960 37.2 35.7 5355 4820 150 BXRE-50C1001-B-8x 70 100 32.9 3.3 687 618 209 150 33.6 5 1003 902 199 200 34.2 6.8 1317 1186 193 270 35 9.5 1725 1553 182 400 36.5 14.6 2451 2206 168 500 37.5 18.7 2968 2671 158 BXRE-50C1001-C-8x 70 150 29.8 4.5 930 837 208 225 30.3 6.8 1358 1222 199 300 30.7 9.2 1776 1599 193 360 31.1 11.2 2105 1894 188 600 32.4 19.4 3362 3026 173 1000 34.3 34.3 5258 4732 153 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25°C (V) Typical Power Tc = 25°C (W) Typical Flux2 Tc = 25°C (lm) Typical DC Flux3 Tc = 85°C (lm) Typical Efficacy Tc = 25°C (lm/W) BXRE-50E1001-A-8x 80 150 32.5 4.9 944 849 193 225 33 7.4 1377 1239 185 300 33.5 10.1 1801 1621 179 360 33.9 12.2 2134 1921 175 600 35.3 21.2 3410 3069 161 960 37.2 35.7 5151 4636 144 BXRE-50E1001-B-8x 80 100 32.9 3.3 661 594 201 150 33.6 5 965 868 192 200 34.2 6.8 1267 1140 185 270 35 9.5 1660 1494 175 400 36.5 14.6 2358 2122 162 500 37.5 18.7 2855 2570 152 BXRE-50E1001-C-8x 80 150 29.8 4.5 895 806 200 225 30.3 6.8 1306 1175 192 300 30.7 9.2 1709 1538 185 360 31.1 11.2 2025 1822 181 600 32.4 19.4 3234 2911 166 1000 34.3 34.3 5058 4552 147 BXRE-50G1001-A-8x 90 150 32.5 4.9 816 734 167 225 33 7.4 1190 1071 160 300 33.5 10.1 1557 1401 155 360 33.9 12.2 1845 1660 151 600 35.3 21.2 2947 2653 139 960 37.2 35.7 4453 4008 125 BXRE-50G1001-B-8x 90 100 32.9 3.3 571 514 174 150 33.6 5 834 750 166 200 34.2 6.8 1095 986 160 270 35 9.5 1435 1291 152 400 36.5 14.6 2038 1834 140 500 37.5 18.7 2468 2221 132 BXRE-50G1001-C-8x 90 150 29.8 4.5 774 696 173 225 30.3 6.8 1129 1016 166 300 30.7 9.2 1477 1329 160 360 31.1 11.2 1750 1575 156 600 32.4 19.4 2796 2516 144 1000 34.3 34.3 4372 3935 127 BXRE-57C1001-A-8x 70 150 32.5 4.9 954 859 196 225 33 7.4 1392 1253 187 300 33.5 10.1 1822 1639 181 360 33.9 12.2 2158 1943 177 600 35.3 21.2 3448 3103 163 960 37.2 35.7 5210 4689 146 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25°C (V) Typical Power Tc = 25°C (W) Typical Flux2 Tc = 25°C (lm) Typical DC Flux3 Tc = 85°C (lm) Typical Efficacy Tc = 25°C (lm/W) BXRE-57C1001-B-8x 70 100 32.9 3.3 668 601 203 150 33.6 5 975 878 194 200 34.2 6.8 1281 1153 187 270 35 9.5 1678 1511 177 400 36.5 14.6 2384 2146 163 500 37.5 18.7 2888 2599 154 BXRE-57C1001-C-8x 70 150 29.8 4.5 905 815 202 225 30.3 6.8 1321 1189 194 300 30.7 9.2 1728 1555 187 360 31.1 11.2 2047 1843 183 600 32.4 19.4 3271 2944 168 1000 34.3 34.3 5115 4604 149 BXRE-57E1001-A-8x 80 150 32.5 4.9 906 816 186 225 33 7.4 1322 1190 178 300 33.5 10.1 1730 1557 172 360 33.9 12.2 2050 1845 168 600 35.3 21.2 3275 2947 155 960 37.2 35.7 4948 4453 138 BXRE-57E1001-B-8x 80 100 32.9 3.3 634 571 193 150 33.6 5 926 834 184 200 34.2 6.8 1217 1095 178 270 35 9.5 1594 1435 169 400 36.5 14.6 2264 2038 155 500 37.5 18.7 2742 2468 146 BXRE-57E1001-C-8x 80 150 29.8 4.5 860 774 192 225 30.3 6.8 1254 1129 184 300 30.7 9.2 1641 1477 178 360 31.1 11.2 1944 1750 174 600 32.4 19.4 3106 2796 160 1000 34.3 34.3 4858 4372 141 BXRE-65C1001-A-8x 70 150 32.5 4.9 954 859 196 225 33 7.4 1392 1253 187 300 33.5 10.1 1822 1639 181 360 33.9 12.2 2158 1943 177 600 35.3 21.2 3448 3103 163 960 37.2 35.7 5210 4689 146 BXRE-65C1001-B-8x 70 100 32.9 3.3 668 601 203 150 33.6 5 975 878 194 200 34.2 6.8 1281 1153 187 270 35 9.5 1678 1511 177 400 36.5 14.6 2384 2146 163 500 37.5 18.7 2888 2599 154 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25°C (V) Typical Power Tc = 25°C (W) Typical Flux2 Tc = 25°C (lm) Typical DC Flux3 Tc = 85°C (lm) Typical Efficacy Tc = 25°C (lm/W) BXRE-65C1001-C-8x 70 150 29.8 4.5 905 815 202 225 30.3 6.8 1321 1189 194 300 30.7 9.2 1728 1555 187 360 31.1 11.2 2047 1843 183 600 32.4 19.4 3271 2944 168 1000 34.3 34.3 5115 4604 149 BXRE-65E1001-A-8x 80 150 32.5 4.9 917 825 188 225 33 7.4 1338 1204 180 300 33.5 10.1 1750 1575 174 360 33.9 12.2 2074 1867 170 600 35.3 21.2 3313 2982 156 960 37.2 35.7 5006 4505 140 BXRE-65E1001-B-8x 80 100 32.9 3.3 642 578 195 150 33.6 5 937 844 186 200 34.2 6.8 1231 1108 180 270 35 9.5 1613 1452 171 400 36.5 14.6 2291 2062 157 500 37.5 18.7 2775 2497 148 BXRE-65E1001-C-8x 80 150 29.8 4.5 870 783 194 225 30.3 6.8 1269 1142 186 300 30.7 9.2 1660 1494 180 360 31.1 11.2 1967 1771 176 600 32.4 19.4 3143 2829 162 1000 34.3 34.3 4915 4424 143 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Electrical Characteristics

Table 5: Electrical Characteristics Part Number Drive Current (mA) Forward Voltage Pulsed, Tc = 25°C (V) 1, 2, 3, 8 Typical Coefficient of Forward Voltage4 ∆Vf/∆Tc (mV/°C) Typical Thermal Resistance Junction to Case5,6 Rj-c (°C/W) Driver Selection Voltages7 (V) Minimum Typical Maximum Vf Min. Hot Tc = 105°C (V) Vf Max. Cold Tc = -40°C (V) BXRE-xxx100x-A-8x BXRE-xxx100x-B-8x BXRE-xxx100x-C-8x Notes for Table 5: 1. Parts are tested in pulsed conditions, Tc = 25°C. Pulse width is 10ms. 2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance. 3. Bridgelux maintains a tester tolerance of ± 0.10V on forward voltage measurements. 4. Typical coefficient of forward voltage tolerance is ± 0.1mV for nominal current. 5. Thermal resistance values are based from test data of a 3000K 80 CRI product. 6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal interface material used during testing is not included in the thermal resistance value. 7. Vf min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design and selection over the operating range of the product. 8. This product has been designed and manufactured per IEC 62031:2018 This product has passed dielectric withstand voltage testing at 1140 V. The working voltage designated for the insulation is 70V d.c. The maximum allowable voltage across the array must be determined in the end product application.

Table 6: Eye Safety Risk Group (RG) Classifications Part Number Drive Current (mA) CCT5 2700K/3000K 4000K2 5000K3 6500K4 BXRE-xxx100x-A-8x

355 RG1 RG1 RG1 RG1

495 RG1 RG1 RG1 RG2

655 RG1 RG1 RG2 RG2

960 RG1 RG2 RG2 RG2

500 RG1 RG1 RG1 RG2

395 RG1 RG1 RG1 RG1

550 RG1 RG1 RG1 RG2

730 RG1 RG1 RG2 RG2

1000 RG1 RG2 RG2 RG2

Notes for Table 6: 1. Eye safety classification for the use of Bridgelux V Series LED arrays is in accordance with specification IEC/TR 62778: Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires. 2. For products classified as RG2 at 4000K, Ethr= 1980 lx. 3. For products classified as RG2 at 5000K Ethr= 1530 lx. 4. For products classified as RG2 at 6500K, Ethr= 1170 lx. 5. Please contact your Bridgelux sales representative for Ethr values at specific drive currents and CCTs not listed.

LED Junction Temperature (Tj) 150°C Storage Temperature -40°C to +105°C Operating Case Temperature1 (Tc) 105°C Soldering Temperature2 350°C or lower for a maximum of 6 seconds BXRE-xxx100x-A-8x BXRE-xxx100x-B-8x BXRE-xxx100x-C-8x Maximum Drive Current3 960mA 500mA 1000mA Maximum Peak Pulsed Drive Current4 1120mA 560mA 1120mA Maximum Reverse Voltage5 -60V -60V -55V Table 7: Maximum Ratings Notes for Table 7: 1. For IEC 62717 requirement, please consult your Bridgelux sales representative. 2. Refer to Bridgelux Application Note AN101: Handling and Assembly of Bridgelux V Series LED Arrays. 3. Arrays may be driven at higher currents however lumen maintenance may be reduced. and warranty will not apply. 4. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed current specified. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures. 5. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating provided for reference only.

Figure 12: Typical Color Spectrum Notes for Figure 12: 1. Color spectra measured at nominal current for Tj = Tc = 25°C. 2. Color spectra shown is 3000K and 80 CRI. 3. Color spectra shown is 4000K and 80 CRI. 4. Color spectra shown is 5000K and 70 CRI. 4. Color spectra shown is 6500K and 70 CRI. 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 110% 400 450 500 550 600 650 700 750 800 Relative Spectral Power Distribution Wavelength (nm) 3000K 4000K 5000K 6500K

Figure 13 Drawing for V10 LED Array Notes for Figure 13: 1. Drawings are not to scale. 2. Drawing dimensions are in millimeters. 3. Unless otherwise specified, tolerances are ±0.1mm. 4. Solder pad labeled “+” denotes positive contact. 5. Refer to Application Notes AN101 for product handling, mounting and heat sink recommendations. 6. The optical center of the LED Array is nominally defined by the mechanical center of the array to a tolerance of ± 0.2mm. 7. Bridgelux maintains a flatness of 0.10mm across the mounting surface of the array.

Bin Code 2200K 2400K 2700K 3000K 3500K 4000K ANSI Bin (for reference only) (2207K-2309K) (2300K-2500K) (2580K - 2870K) (2870K - 3220K) (3220K - 3710K) (3710K - 4260K) 83 (3 SDCM) (2207K-2309K) (2336K-2454K) (2651K - 2794K) (2968K - 3136K) (3369K - 3586K) (3851K - 4130K) 82 (2 SDCM) (2224K-2291K) (2355K-2433K) (2674K - 2769K) (2995K - 3107K) (3404K - 3548K) (3895K - 4081K) Table 8: Warm and Neutral White xy Bin Coordinates and Associated Typical CCT Bin Code 5000K 5700K 6500K ANSI Bin (for reference only) (4745K - 5311K) (5312K - 6022K) (6022K - 7042K) 84 (4 SDCM) (4801K - 5282K) (5395K- 5970K) (6200K - 6910K) 83 (3 SDCM) (4835K - 5215K) (5460K- 5891K) (6279K -6811K) Table 9: Cool White xy Bin Coordinates and Associated Typical CCT (product is hot targeted to Tc = 85°C) Figure 14: Warm and Neutral White Test Bins in xy Color Space Note: Pulsed Test Conditions, Tc = 25°C Figure 15: Cool White Test Bins in xy Color Space Note: Pulsed Test Conditions, Tc = 25°C 0.3 0.31 0.32 0.33 0.34 0.35 0.36 0.37 0.38 0.39 Y X

4 SDCM

3 SDCM

Note for Tables 8-9: 1. Bridgelux maintains a tolerance of +/- 0.007 on x and y color coordinates in the CIE 1931 color Space.

Figure 16: V10 Packaging Tube Notes for Figure 16: 1. Each tube holds 35 V10 COB arrays. 2. One tube is sealed in an anti-static bag. Four bags are placed in a shipping box. Depending on quantities ordered, a bigger shipping box, containing four boxes may be used to ship products. 3. Each bag and box is to be labeled as shown above. box are 58.7 x 13.3 x 7.9 cm

Figure 17: Gen. 8 Product Labeling Bridgelux COB arrays have laser markings on the back side of the substrate to help with product identification. In addition to the product identification markings, Bridgelux COB arrays also contain markings for internal Bridgelux manufacturing use only. The image below shows which markings are for customer use and which ones are for Bridgelux internal use only. The Bridgelux internal manufacturing markings are subject to change without notice, however these will not impact the form, function or performance of the COB array. Customer Use- 2D Barcode Scannable barcode provides product part number and other Bridgelux internal production information. Customer Use- Product part number 30E1000C 83 2F Customer Use- Vf Bin Code included to enable greater luminaire design flexibility. Refer to AN92 for bin code definitions. Internal Bin Code

Bridgelux has developed a comprehensive set of application notes and design resources to assist customers in successfully designing with the V Series product family of LED array products. For all available application notes visit www.bridgelux.com. Optical Source Models Optical source models and ray set files are available for all Bridgelux products. For a list of available formats, visit www.bridgelux.com. MINOR PRODUCT CHANGE POLICY The rigorous qualification testing on products offered by Bridgelux provides performance assurance. Slight cosmetic changes that do not affect form, fit, or function may occur as Bridgelux continues product optimization. CAUTION: CHEMICAL EXPOSURE HAZARD Exposure to some chemicals commonly used in luminaire manufacturing and assembly can cause damage to the LED array. Please consult Bridgelux CAUTION: RISK OF BURN Do not touch the V Series LED array during operation. Allow the array to cool for a sufficient period of time before handling. The V Series LED array may reach elevated temperatures such that could burn skin when touched. 3D CAD Models Three dimensional CAD models depicting the product outline of all Bridgelux V Series LED arrays are available in both IGS and STEP formats. Please contact your Bridgelux sales representative for assistance. LM80 LM80 testing has been completed and the LM80 report is now available. Please contact your Bridgelux sales representative for LM-80 report. STANDARD TEST CONDITIONS Unless otherwise stated, array testing is performed at the nominal drive current. CAUTION CONTACT WITH LIGHT EMITTING SURFACE (LES) Avoid any contact with the LES. Do not touch the LES of the LED array or apply stress to the LES (yellow phosphor resin area). Contact may cause damage to the LED array. Optics and reflectors must not be mounted in contact with the LES (yellow phosphor resin area).

About Bridgelux: Bridging Light and Life™ © 2025 Bridgelux, Inc. All rights reserved. Product specifications are subject to change without notice. Bridgelux, the Bridgelux stylized logo design, Vero, V Series and V Series HD are registered trademarks, and Decor Series is a trademark of Bridgelux, Inc. All other trademarks are the property of their respective owners. Bridgelux Gen 8 V10 Array Series Product Data Sheet DS412 Rev. G (05/2025)

46410 Fremont Boulevard

Fremont, CA 94538 U.S.A. Tel (925) 583-8400 www.bridgelux.com At Bridgelux, we help companies, industries and people experience the power and possibility of light. Since 2002, we’ve designed LED solutions that are high performing, energy efficient, cost effective and easy to integrate. Our focus is on light’s impact on human behavior, delivering products that create better environments, experiences and returns—both experiential and financial. And our patented technology drives new platforms for commercial and industrial luminaires. For more information about the company, please visit bridgelux.com twitter.com/Bridgelux facebook.com/Bridgelux youtube.com/user/Bridgelux linkedin.com/company/bridgelux-inc-_2 WeChat ID: BridgeluxInChina