The V Series™ LED Array products deliver high quality light in a compact and cost-effective solid-state lighting package. These chip on board (CoB) arrays can be efficiently driven up to three times the nominal drive current, enabling design flexibility not previously possible. These high flux density light sources are designed to support a wide range of high quality, low cost directional luminaires and replacement lamps for both interior and exterior commercial and residential applications. The V8 LED Array is available in a variety of electrical, CCT, and CRI combinations providing substantial design flexibility and energy efficiency advantages. Lighting system designs incorporating these LED arrays deliver increased system level efficacy and a longer service life. Typical applications include replacement lamps and task, accent, spot, track, wide area, security, wall packs and down lights. V Series
Features
- Efficacy of 178 lm/W typical for 3000K, 80 CRI
- Compact high flux density light source
- Uniform, high quality illumination
- Minimum 70, 80, and 90 CRI options
- Streamlined thermal path
- ENERGY STAR® / ANSI compliant color binning structure with 2, 3 and 4 SDCM standard
- More energy efficient than incandescent, halogen and fluorescent lamps
- Low voltage DC operation
- Instant light with unlimited dimming
- V f bin code backside marking Benefits
- Enhanced optical control
- Clean white light without pixilation
- High quality, true color reproduction
- Significantly reduced thermal resistance and increased operating temperatures
- Uniform, consistent white light
- Lower operating costs
- Easy to use with daylight and motion detectors to enable increased energy savings
- Reduced maintenance costs
- Environmentally friendly, no disposal issues
Bridgelux arrays are fully engineered devices that provide consistent thermal and optical performance on an engineered mechanical platform. The V Series arrays are the most compact CoB devices across all of Bridgelux’s LED Array products. Product Nomenclature The part number designation for Bridgelux V Series LED arrays is explained as follows: The arrays incorporate several features to simplify design integration and assembly. Please visit www.bridgelux.com for more information on the V Series family of products. 1 2 3 4 – 5 6 7 8 9 10 11 – 12 – 13 14 Product Family CCT Bin Options 2 = 2 SDCM 3 = 3 SDCM 4 = 4 SDCM Flux Indicator 080x = 800lm Minimum CRI C = 70 CRI min. E = 80 CRI min. G = 90 CRI min. H = 97 CRI typ. Array Configuration Nominal CCT 27 = 2,700K 30 = 3,000K 35 = 3,500K 40 = 4,000K 50 = 5,000K 57 = 5,700K 65 = 6,500K BXRE – 30 G 080 0 – D – 8 2 Note: Part number and lot codes are scribed on back of array Gen. 8 Polarity symbols Solder pads White ring around LES Case Temperature (Tc) Measurement Point Yellow phosphor Light Emitting Surface (LES) Color Targeting Designator 0 = Cold Targeted 1 = Hot Targeted C = Décor Series Showcase Fully engineered substrate for consistent thermal, mechanical and optical properties
The following product configurations are available: Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRE-22E0800-D-8X 2200 80 300 713 625 16.8 5.0 143 BXRE-22E0800-E-8X 2200 80 150 713 625 33.5 5.0 143 BXRE-22G0800-D-8X 2200 90 300 577 506 16.8 5.0 115 BXRE-22G0800-E-8X 2200 90 150 577 506 33.5 5.0 115 BXRE-27E0800-D-8x 2700 80 300 842 741 16.8 5.0 167 BXRE-27E0800-E-8x 2700 80 150 842 741 33.5 5.0 168 BXRE-27G0800-D-8x 2700 90 300 695 612 16.8 5.0 138 BXRE-27G0800-E-8x 2700 90 150 695 612 33.5 5.0 138 BXRE-27G08H0-D-8x 2700 90 300 725 638 16.8 5.0 144 BXRE-27G08H0-E-8x 2700 90 150 725 638 33.5 5.0 144 BXRE-27H0800-D-8x 2700 97 300 616 542 16.8 5.0 122 BXRE-27H0800-E-8x 2700 97 150 616 542 33.5 5.0 123 BXRE-30C0801-D-8x 3000 70 300 937 825 16.8 5.0 186 BXRE-30C0801-E-8x 3000 70 150 937 825 33.5 5.0 186 BXRE-30E0800-D-8x 3000 80 300 895 788 16.8 5.0 178 BXRE-30E0800-E-8x 3000 80 150 895 788 33.5 5.0 178 BXRE-30G0800-D-8x 3000 90 300 727 639 16.8 5.0 144 BXRE-30G0800-E-8x 3000 90 150 727 639 33.5 5.0 145 BXRE-30G08H0-D-8x 3000 90 300 761 669 16.8 5.0 151 BXRE-30G08H0-E-8x 3000 90 150 761 669 33.5 5.0 151 BXRE-30H0800-D-8x 3000 97 300 658 579 16.8 5.0 131 BXRE-30H0800-E-8x 3000 97 150 658 579 33.5 5.0 131 BXRE-35E0800-D-8x 3500 80 300 916 806 16.8 5.0 182 BXRE-35E0800-E-8x 3500 80 150 916 806 33.5 5.0 182 BXRE-35G0800-D-8x 3500 90 300 753 663 16.8 5.0 149 BXRE-35G0800-E-8x 3500 90 150 753 663 33.5 5.0 150 BXRE-40C0801-D-8x 4000 70 300 963 848 16.8 5.0 191 BXRE-40C0801-E-8x 4000 70 150 963 848 33.5 5.0 192 BXRE-40E0800-D-8x 4000 80 300 921 811 16.8 5.0 183 BXRE-40E0800-E-8x 4000 80 150 921 811 33.5 5.0 183 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Décor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, Minimum R9 value is 60 for 90 CRI products on 2700K/3000K/3500K and 4000K, it is 50 on 5000K/5700K and 6500K. But for the CRI90 H0 products (higher efficiency CRI90 version), minimum R9 value is 55 on 2700K/3000K/3500K and 4000K. Minimum R9 value for 97 CRI products is 93 on 2700K and 3000K,and it is 85 on 3500K /4000K/5000K and 5700K. Bridgelux maintains a ± 3 tolerance on R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test.
Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (Continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRE-40G0800-D-8x 4000 90 300 769 676 16.8 5.0 153 BXRE-40G0800-E-8x 4000 90 150 769 676 33.5 5.0 153 BXRE-50C0801-D-8x 5000 70 300 969 852 16.8 5.0 192 BXRE-50C0801-E-8x 5000 70 150 969 852 33.5 5.0 193 BXRE-50E0801-D-8x 5000 80 300 932 820 16.8 5.0 185 BXRE-50E0801-E-8x 5000 80 150 932 820 33.5 5.0 185 BXRE-50G0801-D-8x 5000 90 300 806 709 16.8 5.0 160 BXRE-50G0801-E-8x 5000 90 150 806 709 33.5 5.0 160 BXRE-57C0801-D-8x 5700 70 300 942 829 16.8 5.0 187 BXRE-57C0801-E-8x 5700 70 150 942 829 33.5 5.0 188 BXRE-57E0801-D-8x 5700 80 300 895 788 16.8 5.0 178 BXRE-57E0801-E-8x 5700 80 150 895 788 33.5 5.0 178 BXRE-65C0801-D-8x 6500 70 300 942 829 16.8 5.0 187 BXRE-65C0801-E-8x 6500 70 150 942 829 33.5 5.0 188 BXRE-65E0801-D-8x 6500 80 300 906 797 16.8 5.0 180 BXRE-65E0801-E-8x 6500 80 150 906 797 33.5 5.0 180 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Décor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, Minimum R9 value is 60 for 90 CRI products on 2700K/3000K/3500K and 4000K, it is 50 on 5000K/5700K and 6500K. But for the CRI90 H0 products (higher efficiency CRI90 version), minimum R9 value is 55 on 2700K/3000K/3500K and 4000K. Minimum R9 value for 97 CRI products is 93 on 2700K and 3000K,and it is 85 on 3500K /4000K/5000K and 5700K. Bridgelux maintains a ± 3 tolerance on R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test.
Table 2: Selection Guide, Stabilized DC Performance (Tc = 85°C) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRE-22E0800-D-8X 2200 80 300 639 563 16.5 4.9 131 BXRE-22E0800-E-8X 2200 80 150 639 563 32.9 4.9 131 BXRE-22G0800-D-8X 2200 90 300 517 455 16.5 4.9 106 BXRE-22G0800-E-8X 2200 90 150 517 455 32.9 4.9 106 BXRE-27E0800-D-8x 2700 80 300 758 667 16.5 4.9 154 BXRE-27E0800-E-8x 2700 80 150 758 667 32.9 4.9 154 BXRE-27G0800-D-8x 2700 90 300 625 550 16.5 4.9 127 BXRE-27G0800-E-8x 2700 90 150 625 550 32.9 4.9 127 BXRE-27G08H0-D-8x 2700 90 300 652 574 16.5 4.9 132 BXRE-27G08H0-E-8x 2700 90 150 652 574 32.9 4.9 132 BXRE-27H0800-D-8x 2700 97 300 554 488 16.5 4.9 112 BXRE-27H0800-E-8x 2700 97 150 554 488 32.9 4.9 112 BXRE-30C0801-D-8x 3000 70 300 843 742 16.5 4.9 171 BXRE-30C0801-E-8x 3000 70 150 843 742 32.9 4.9 171 BXRE-30E0800-D-8x 3000 80 300 806 709 16.5 4.9 163 BXRE-30E0800-E-8x 3000 80 150 806 709 32.9 4.9 163 BXRE-30G0800-D-8x 3000 90 300 654 575 16.5 4.9 132 BXRE-30G0800-E-8x 3000 90 150 654 575 32.9 4.9 132 BXRE-30G08H0-D-8x 3000 90 300 685 603 16.5 4.9 139 BXRE-30G08H0-E-8x 3000 90 150 685 603 32.9 4.9 139 BXRE-30H0800-D-8x 3000 97 300 592 521 16.5 4.9 120 BXRE-30H0800-E-8x 3000 97 150 592 521 32.9 4.9 120 BXRE-35E0800-D-8x 3500 80 300 824 726 16.5 4.9 167 BXRE-35E0800-E-8x 3500 80 150 824 726 32.9 4.9 167 BXRE-35G0800-D-8x 3500 90 300 678 596 16.5 4.9 137 BXRE-35G0800-E-8x 3500 90 150 678 596 32.9 4.9 137 BXRE-40C0801-D-8x 4000 70 300 867 763 16.5 4.9 176 BXRE-40C0801-E-8x 4000 70 150 867 763 32.9 4.9 176 BXRE-40E0800-D-8x 4000 80 300 829 730 16.5 4.9 168 BXRE-40E0800-E-8x 4000 80 150 829 730 32.9 4.9 168 Notes for Table 2: 1. Nominal CCT as defined by ANSI C78.377-2011. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Décor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, Minimum R9 value is 60 for 90 CRI products on 2700K/3000K/3500K and 4000K, it is 50 on 5000K/5700K and 6500K. But for the CRI90 H0 products (higher efficiency CRI90 version), minimum R9 value is 55 on 2700K/3000K/3500K and 4000K. Minimum R9 value for 97 CRI products is 93 on 2700K and 3000K,and it is 85 on 3500K /4000K/5000K and 5700K. Bridgelux maintains a ± 3 tolerance on R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
Table 2: Selection Guide, Stabilized DC Performance (Tc = 85°C) (Continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRE-40G0800-D-8x 4000 90 300 692 609 16.5 4.9 140 BXRE-40G0800-E-8x 4000 90 150 692 609 32.9 4.9 140 BXRE-50C0801-D-8x 5000 70 300 872 767 16.5 4.9 177 BXRE-50C0801-E-8x 5000 70 150 872 767 32.9 4.9 177 BXRE-50E0801-D-8x 5000 80 300 839 738 16.5 4.9 170 BXRE-50E0801-E-8x 5000 80 150 839 738 32.9 4.9 170 BXRE-50G0801-D-8x 5000 90 300 725 638 16.5 4.9 147 BXRE-50G0801-E-8x 5000 90 150 725 638 32.9 4.9 147 BXRE-57C0801-D-8x 5700 70 300 848 746 16.5 4.9 172 BXRE-57C0801-E-8x 5700 70 150 848 746 32.9 4.9 172 BXRE-57E0801-D-8x 5700 80 300 806 709 16.5 4.9 163 BXRE-57E0801-E-8x 5700 80 150 806 709 32.9 4.9 163 BXRE-65C0801-D-8x 6500 70 300 848 746 16.5 4.9 172 BXRE-65C0801-E-8x 6500 70 150 848 746 32.9 4.9 172 BXRE-65E0801-D-8x 6500 80 300 815 717 16.5 4.9 165 BXRE-65E0801-E-8x 6500 80 150 815 717 32.9 4.9 165 Notes for Table 2: 1. Nominal CCT as defined by ANSI C78.377-2011. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Décor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, Minimum R9 value is 60 for 90 CRI products on 2700K/3000K/3500K and 4000K, it is 50 on 5000K/5700K and 6500K. But for the CRI90 H0 products (higher efficiency CRI90 version), minimum R9 value is 55 on 2700K/3000K/3500K and 4000K. Minimum R9 value for 97 CRI products is 93 on 2700K and 3000K,and it is 85 on 3500K /4000K/5000K and 5700K. Bridgelux maintains a ± 3 tolerance on R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
European Product Registry for Energy Labeling The European Product Registry for Energy Labeling (EPREL) is defined in the EU Regulation 2017/1369 to provide import- ant energy efficiency information to consumers. Together with Energy Labeling Regulation ELR (EU) 2019/2015 which was amended by regulation (EU) 2021/340 for energy labelling of light sources, manufacturers are required to declare an ener- gy class based on key technical specifications from each of their product and register it in an open data base managed by EPREL It is now a legal requirement for a vendor of light sources to upload information about their products into the EPREL database before placing these products on the market in the EU. Table 3 below provides a list of part numbers that are in compliance with ELR and are currently listed in the EPREL data- base. At Bridgelux, we are fully committed to supplying products that are compliant with pertinent laws, rules, and obligation imposed by relevant government bodies including the European Energy Labeling regulation. Customers can use these products with full confidence for any projects that fall under the ELR. Table 3: Part numbers registered in European Product Registry for Energy Labeling PART NUMBER1 CCT (K) CRI Current2 (mA) Vf (V) Useful flux3 (Φuse) at 85C (lm) Pow- er (W) Efficacy (lm/W) Energy efficiency class4 Regis- tration No URL to Product Information Sheet in EPREL Database Notes for Table 3: 1. All device listed here must be disposed as e-waste upon its end of life according to local country guideline in each country. 2. For information on performance values at alternative drive conditions. please refer to the Product Selection Guide, Absolute Maximum Rating Table and Performance Curves in this data sheet. 3. For a definition of useful luminous flux (ΦΦuse), please see the ELR regulations at https:/ /tinyurl.com/4b6zvt4m. 4. EPREL requires an arrow symbol containing the letter of the energy efficiency class to be displayed. on technical promotional material. Refer to this energy efficiency class column for specific energy efficiency class on each part number.
European Product Registry for Energy Labeling Table 3: Part numbers registered in European Product Registry for Energy Labeling (Continued) PART NUMBER1 CCT (K) CRI Current2 (mA) Vf (V) Useful flux3 (Φuse) at 85C (lm) Pow- er (W) Efficacy (lm/W) Energy efficiency class4 Regis- tration No URL to Product Information Sheet in EPREL Database Notes for Table 3: 1. All device listed here must be disposed as e-waste upon its end of life according to local country guideline in each country. 2. For information on performance values at alternative drive conditions. please refer to the Product Selection Guide, Absolute Maximum Rating Table and Performance Curves in this data sheet. 3. For a definition of useful luminous flux (ΦΦuse), please see the ELR regulations at https:/ /tinyurl.com/4b6zvt4m. 4. EPREL requires an arrow symbol containing the letter of the energy efficiency class to be displayed. on technical promotional material. Refer to this energy efficiency class column for specific energy efficiency class on each part number.
Performance at Commonly Used Drive Currents V Series LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. V Series may also be driven at other drive currents dependent on specific application design requirements. The performance at any drive current can be derived from the current vs. voltage characteristics shown in Figures 1 and 2 and the flux vs. current characteristics shown in Figures 3 and 4. The performance at commonly used drive currents is summarized in Table 4. Table 4: Product Performance at Commonly Used Drive Currents Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRE-22E0800-D-8X 80 150 16.3 2.4 371 333 155 225 16.5 3.7 542 486 146 300 16.8 5.0 713 639 143 518 17.5 9.1 1173 1052 129 718 18.1 13.0 1572 1409 121 1000 18.9 18.9 2088 1872 110 BXRE-22E0800-E-8X 80 75 32.4 2.4 371 333 155 110 33.0 3.6 531 476 147 150 33.5 5.0 713 639 143 175 33.9 5.9 818 734 139 250 34.9 8.7 1136 1018 131 500 37.7 18.8 2088 1872 111 BXRE-22G0800-D-8X 90 150 16.3 2.4 300 269 125 225 16.5 3.7 438 393 118 300 16.8 5.0 577 517 115 518 17.5 9.1 948 850 104 718 18.1 13.0 1270 1139 98 1000 18.9 18.9 1688 1513 89 BXRE-22G0800-E-8X 90 75 32.4 2.4 300 269 125 110 33.0 3.6 429 385 119 150 33.5 5.0 577 517 115 175 33.9 5.9 661 593 112 250 34.9 8.7 918 823 106 500 37.7 18.8 1688 1513 90 BXRE-27E0800-D-8x 80 150 16.3 2.4 438 395 180 225 16.5 3.7 640 576 172 300 16.8 5.0 842 758 167 518 17.5 9.1 1385 1247 153 718 18.1 13.0 1856 1670 143 1000 18.9 18.9 2466 2219 131 BXRE-27E0800-E-8x 80 75 32.4 2.4 438 395 180 110 33.0 3.6 627 564 173 150 33.5 5.0 842 758 167 175 33.9 5.9 966 870 163 250 34.9 8.7 1342 1207 154 500 37.7 18.8 2466 2219 131 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRE-27G0800-D-8x 90 150 16.3 2.4 362 326 148 225 16.5 3.7 528 475 142 300 16.8 5.0 695 625 138 518 17.5 9.1 1143 1029 126 718 18.1 13.0 1531 1378 118 1000 18.9 18.9 2034 1831 108 BXRE-27G0800-E-8x 90 75 32.4 2.4 362 326 149 110 33.0 3.6 517 465 143 150 33.5 5.0 695 625 138 175 33.9 5.9 797 717 134 250 34.9 8.7 1107 996 127 500 37.7 18.8 2034 1831 108 BXRE-27G08H0-D-8x 90 150 16.3 2.4 377 340 155 225 16.5 3.7 551 496 148 300 16.8 5.0 725 652 144 518 17.5 9.1 1192 1073 131 718 18.1 13.0 1597 1437 123 1000 18.9 18.9 2122 1910 112 BXRE-27G08H0-E-8x 90 75 32.4 2.4 377 340 155 110 33.0 3.6 539 485 149 150 33.5 5.0 725 652 144 175 33.9 5.9 832 748 140 250 34.9 8.7 1155 1039 132 500 37.7 18.8 2122 1910 113 BXRE-27H0800-D-8x 97 150 16.3 2.4 321 289 131 225 16.5 3.7 468 421 126 300 16.8 5.0 616 554 122 518 17.5 9.1 1013 912 112 718 18.1 13.0 1357 1221 104 1000 18.9 18.9 1803 1623 95 BXRE-27H0800-E-8x 97 75 32.4 2.4 321 289 132 110 33.0 3.6 458 412 126 150 33.5 5.0 616 554 122 175 33.9 5.9 707 636 119 250 34.9 8.7 981 883 113 500 37.7 18.8 1803 1623 96 BXRE-30C0801-D-8x 70 150 16.3 2.4 488 439 200 225 16.5 3.7 712 641 191 300 16.8 5.0 937 843 186 518 17.5 9.1 1541 1387 170 718 18.1 13.0 2065 1858 159 1000 18.9 18.9 2743 2469 145 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRE-30C0801-E-8x 70 75 32.4 2.4 488 439 200 110 33.0 3.6 697 627 192 150 33.5 5.0 937 843 186 175 33.9 5.9 1075 967 181 250 34.9 8.7 1492 1343 171 500 37.7 18.8 2743 2469 146 BXRE-30E0800-D-8x 80 150 16.3 2.4 466 419 191 225 16.5 3.7 680 612 183 300 16.8 5.0 895 806 178 518 17.5 9.1 1472 1325 162 718 18.1 13.0 1972 1775 151 1000 18.9 18.9 2620 2358 139 BXRE-30E0800-E-8x 80 75 32.4 2.4 466 419 191 110 33.0 3.6 666 599 184 150 33.5 5.0 895 806 178 175 33.9 5.9 1027 924 173 250 34.9 8.7 1425 1283 164 500 37.7 18.8 2620 2358 139 BXRE-30G0800-D-8x 90 150 16.3 2.4 378 340 155 225 16.5 3.7 552 497 148 300 16.8 5.0 727 654 144 518 17.5 9.1 1195 1075 132 718 18.1 13.0 1601 1441 123 1000 18.9 18.9 2127 1914 113 BXRE-30G0800-E-8x 90 75 32.4 2.4 378 340 155 110 33.0 3.6 541 486 149 150 33.5 5.0 727 654 144 175 33.9 5.9 833 750 141 250 34.9 8.7 1157 1041 133 500 37.7 18.8 2127 1914 113 BXRE-30G08H0-D-8x 90 150 16.3 2.4 396 356 162 225 16.5 3.7 578 520 155 300 16.8 5.0 761 685 151 518 17.5 9.1 1251 1126 138 718 18.1 13.0 1676 1508 129 1000 18.9 18.9 2227 2004 118 BXRE-30G08H0-E-8x 90 75 32.4 2.4 396 356 163 110 33.0 3.6 566 509 156 150 33.5 5.0 761 685 151 175 33.9 5.9 873 785 147 250 34.9 8.7 1212 1090 139 500 37.7 18.8 2227 2004 118 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRE-30H0800-D-8x 97 150 16.3 2.4 343 308 140 225 16.5 3.7 500 450 134 300 16.8 5.0 658 592 131 518 17.5 9.1 1082 974 119 718 18.1 13.0 1450 1305 111 1000 18.9 18.9 1927 1734 102 BXRE-30H0800-E-8x 97 75 32.4 2.4 343 308 141 110 33.0 3.6 490 441 135 150 33.5 5.0 658 592 131 175 33.9 5.9 755 679 127 250 34.9 8.7 1048 943 120 500 37.7 18.8 1927 1734 102 BXRE-35E0800-D-8x 80 150 16.3 2.4 477 429 196 225 16.5 3.7 696 626 187 300 16.8 5.0 916 824 182 518 17.5 9.1 1507 1356 166 718 18.1 13.0 2018 1816 155 1000 18.9 18.9 2682 2414 142 BXRE-35E0800-E-8x 80 75 32.4 2.4 477 429 196 110 33.0 3.6 682 613 188 150 33.5 5.0 916 824 182 175 33.9 5.9 1051 946 177 250 34.9 8.7 1459 1313 167 500 37.7 18.8 2682 2414 142 BXRE-35G0800-D-8x 90 150 16.3 2.4 392 353 161 225 16.5 3.7 572 515 154 300 16.8 5.0 753 678 149 518 17.5 9.1 1238 1114 136 718 18.1 13.0 1659 1493 127 1000 18.9 18.9 2204 1984 117 BXRE-35G0800-E-8x 90 75 32.4 2.4 392 353 161 110 33.0 3.6 560 504 154 150 33.5 5.0 753 678 150 175 33.9 5.9 864 777 146 250 34.9 8.7 1199 1079 138 500 37.7 18.8 2204 1984 117 BXRE-40C0801-D-8x 70 150 16.3 2.4 501 451 206 225 16.5 3.7 732 659 197 300 16.8 5.0 963 867 191 518 17.5 9.1 1585 1426 175 718 18.1 13.0 2123 1910 163 1000 18.9 18.9 2820 2538 149 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRE-40C0801-E-8x 70 75 32.4 2.4 501 451 206 110 33.0 3.6 717 645 198 150 33.5 5.0 963 867 192 175 33.9 5.9 1105 995 186 250 34.9 8.7 1534 1381 176 500 37.7 18.8 2820 2538 150 BXRE-40E0800-D-8x 80 150 16.3 2.4 480 432 197 225 16.5 3.7 700 630 188 300 16.8 5.0 921 829 183 518 17.5 9.1 1515 1364 167 718 18.1 13.0 2030 1827 156 1000 18.9 18.9 2697 2427 143 BXRE-40E0800-E-8x 80 75 32.4 2.4 480 432 197 110 33.0 3.6 685 617 189 150 33.5 5.0 921 829 183 175 33.9 5.9 1057 951 178 250 34.9 8.7 1467 1321 168 500 37.7 18.8 2697 2427 143 BXRE-40G0800-D-8x 90 150 16.3 2.4 400 360 164 225 16.5 3.7 584 526 157 300 16.8 5.0 769 692 153 518 17.5 9.1 1264 1138 139 718 18.1 13.0 1693 1524 130 1000 18.9 18.9 2250 2025 119 BXRE-40G0800-E-8x 90 75 32.4 2.4 400 360 164 110 33.0 3.6 572 515 158 150 33.5 5.0 769 692 153 175 33.9 5.9 882 793 149 250 34.9 8.7 1224 1102 140 500 37.7 18.8 2250 2025 119 BXRE-50C0801-D-8x 70 150 16.3 2.4 504 454 207 225 16.5 3.7 736 662 198 300 16.8 5.0 969 872 192 518 17.5 9.1 1593 1434 175 718 18.1 13.0 2134 1921 164 1000 18.9 18.9 2836 2552 150 BXRE-50C0801-E-8x 70 75 32.4 2.4 504 454 207 110 33.0 3.6 721 649 199 150 33.5 5.0 969 872 193 175 33.9 5.9 1111 1000 187 250 34.9 8.7 1543 1388 177 500 37.7 18.8 2836 2552 150 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRE-50E0801-D-8x 80 150 16.3 2.4 485 437 199 225 16.5 3.7 708 637 190 300 16.8 5.0 932 839 185 518 17.5 9.1 1533 1379 169 718 18.1 13.0 2053 1848 158 1000 18.9 18.9 2728 2455 144 BXRE-50E0801-E-8x 80 75 32.4 2.4 485 437 199 110 33.0 3.6 693 624 191 150 33.5 5.0 932 839 185 175 33.9 5.9 1069 962 180 250 34.9 8.7 1484 1336 170 500 37.7 18.8 2728 2455 145 BXRE-50G0801-D-8x 90 150 16.3 2.4 419 377 172 225 16.5 3.7 612 551 165 300 16.8 5.0 806 725 160 518 17.5 9.1 1325 1192 146 718 18.1 13.0 1775 1597 136 1000 18.9 18.9 2358 2122 125 BXRE-50G0801-E-8x 90 75 32.4 2.4 419 377 172 110 33.0 3.6 599 539 165 150 33.5 5.0 806 725 160 175 33.9 5.9 924 832 156 250 34.9 8.7 1283 1155 147 500 37.7 18.8 2358 2122 125 BXRE-57C0801-D-8x 70 150 16.3 2.4 491 441 201 225 16.5 3.7 716 644 192 300 16.8 5.0 942 848 187 518 17.5 9.1 1550 1395 171 718 18.1 13.0 2076 1868 159 1000 18.9 18.9 2759 2483 146 BXRE-57C0801-E-8x 70 75 32.4 2.4 491 441 202 110 33.0 3.6 701 631 193 150 33.5 5.0 942 848 187 175 33.9 5.9 1081 973 182 250 34.9 8.7 1501 1351 172 500 37.7 18.8 2759 2483 146 BXRE-57E0801-D-8x 80 150 16.3 2.4 466 419 191 225 16.5 3.7 680 612 183 300 16.8 5.0 895 806 178 518 17.5 9.1 1472 1325 162 718 18.1 13.0 1972 1775 151 1000 18.9 18.9 2620 2358 139 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRE-57E0801-E-8x 80 75 32.4 2.4 466 419 191 110 33.0 3.6 666 599 184 150 33.5 5.0 895 806 178 175 33.9 5.9 1027 924 173 250 34.9 8.7 1425 1283 164 500 37.7 18.8 2620 2358 139 BXRE-65C0801-D-8x 70 150 16.3 2.4 491 441 201 225 16.5 3.7 716 644 192 300 16.8 5.0 942 848 187 518 17.5 9.1 1550 1395 171 718 18.1 13.0 2076 1868 159 1000 18.9 18.9 2759 2483 146 BXRE-65C0801-E-8x 70 75 32.4 2.4 491 441 202 110 33.0 3.6 701 631 193 150 33.5 5.0 942 848 187 175 33.9 5.9 1081 973 182 250 34.9 8.7 1501 1351 172 500 37.7 18.8 2759 2483 146 BXRE-65E0801-D-8x 80 150 16.3 2.4 471 424 193 225 16.5 3.7 688 619 185 300 16.8 5.0 906 815 180 518 17.5 9.1 1489 1340 164 718 18.1 13.0 1995 1795 153 1000 18.9 18.9 2651 2386 140 BXRE-65E0801-E-8x 80 75 32.4 2.4 471 424 194 110 33.0 3.6 674 606 186 150 33.5 5.0 906 815 180 175 33.9 5.9 1039 935 175 250 34.9 8.7 1442 1298 165 500 37.7 18.8 2651 2386 141 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Electrical Characteristics
Table 5: Electrical Characteristics Part Number Drive Current (mA) Forward Voltage Pulsed, Tc = 25ºC (V) 1, 2, 3, 8 Typical Coefficient of Forward Voltage4 ∆Vf/∆Tc (mV/ºC) Typical Thermal Resistance Junction to Case5,6 Rj-c (ºC/W) Driver Selection Voltages7 (V) Minimum Typical Maximum Vf Min. Hot Tc = 105ºC (V) Vf Max. Cold Tc = -40ºC (V) BXRE-xxx080x-D-8x BXRE-xxx080x-E-8x Notes for Table 5: 1. Parts are tested in pulsed conditions, Tc = 25°C. Pulse width is 10ms. 2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance. 3. Bridgelux maintains a tester tolerance of ± 0.10V on forward voltage measurements. 4. Typical coefficient of forward voltage tolerance is ± 0.1mV for nominal current. 5. Thermal resistance values are based from test data of a 3000K 80 CRI product. 6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal interface material used during testing is not included in the thermal resistance value. 7. Vf min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design and selection over the operating range of the product. 8. This product has been designed and manufactured per IEC 62031:2018. This product has passed dielectric withstand voltage testing at 1140 V. The working voltage designated for the insulation is 70V d.c. The maximum allowable voltage across the array must be determined in the end product application.
Table 6: Eye Safety Risk Group (RG) Classifications Part Number Drive Current (mA) CCT4 2700K/3000K 4000K 5000K2 6500K3 BXRE-xxx080x-D-8x
515 RG1 RG1 RG1 RG1
715 RG1 RG1 RG1 RG2
1000 RG1 RG1 RG2 RG2
260 RG1 RG1 RG1 RG1
360 RG1 RG1 RG1 RG2
500 RG1 RG1 RG2 RG2
Notes for Table 6: 1. Eye safety classification for the use of Bridgelux V Series LED arrays is in accordance with specification IEC/TR 62778: Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires. 2. For products classified as RG2 at 5000K Ethr= 1530 lx. 3. For products classified as RG2 at 6500K, Ethr= 1170 lx. 4. Please contact your Bridgelux sales representative for Ethr values at specific drive currents and CCTs not listed.
LED Junction Temperature (Tj) 150°C Storage Temperature -40°C to +105°C Operating Case Temperature1 (Tc) 105°C Soldering Temperature2 300°C or lower for a maximum of 6 seconds BXRE-xxx080x-D-8x BXRE-xxx080x-E-8x Maximum Drive Current3 1000 mA 500 mA Maximum Peak Pulsed Drive Current4 1120 mA 560 mA Maximum Reverse Voltage5 -30V -60V Notes for Table 7: 1. For IEC 62717 requirement, please consult your Bridgelux sales representative. 2. Refer to Bridgelux Application Note AN101: Handling and Assembly of Bridgelux V Series LED Arrays. 3. Arrays may be driven at higher currents however lumen maintenance may be reduced and warranty will not apply. 4. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed current specified. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures. 5. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating provided for reference only. Table 7: Maximum Ratings
Figure 8: Typical Color Spectrum Notes for Figure 8: 1. Color spectra measured at nominal current for Tj = Tc = 25°C. 2. Color spectra shown is 2700K and 80 CRI. 3. Color spectra shown is 3000K and 80 CRI. 4. Color spectra shown is 4000K and 80 CRI. 5. Color spectra shown is 5000K and 70 CRI. 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 400 450 500 550 600 650 700 750 800 Relative Spectral Power Distribution Wavelength (nm) 27E 30E 40E 50C
Figure 11: V8 LED Array Notes for Figure 11: 1. Drawings are not to scale. 2. Drawing dimensions are in millimeters. 3. Solder pads are labeled “+” and “-“ to denote positive and negative polarity, respectively. 4. Unless otherwise specified, tolerances are ±0.1mm. 5. Refer to Application Notes AN101 for product handling, mounting and heat sink recommendations. 6. The optical center of the LED Array is nominally defined by the mechanical center of the array to a tolerance of ± 0.2mm. 7. Bridgelux maintains a flatness of 0.10mm across the mounting surface of the array.
Figure 12: Graph of Warm and Neutral White Test Bins in xy Color Space Bin Code 2200K 2700K 3000K 3500K 4000K ANSI Bin (for reference only) (2207K-2309K) (2580K - 2870K) (2870K - 3220K) (3220K - 3710K) (3710K - 4260K) 82 (2 SDCM) (2207K-2309K) (2674K - 2769K) (2995K - 3107K) (3404K - 3548K) (3895K - 4081K) 83 (3 SDCM) (2224K-2291K) (2651K - 2794K) (2968K - 3136K) (3369K - 3586K) (3851K - 4130K) Table 8: Warm and Neutral White xy Bin Coordinates and Associated Typical CCT Note: Pulsed Test Conditions, Tc = 25°C Table 9: Cool White xy Bin Coordinates and Associated Typical CCT(product is hot targeted to Tc = 85°C) Figure 13: Graph of Cool White Test Bins in xy Color Space Bin Code 5000K 5700K 6500K ANSI Bin (for reference only) (4745K - 5311K) (5312K - 6022K) (6022K - 7042K) 84 (4 SDCM) (4801K - 5282K) (5395K- 5970K) (6200K - 6910K) 83 (3 SDCM) (4835K - 5215K) (5460K- 5891K) (6279K -6811K) 0.3 0.31 0.32 0.33 0.34 0.35 0.36 0.37 0.38 0.39 Y X
4 SDCM
3 SDCM
Note: Pulsed Test Conditions, Tc = 25°C Note for Tables 8-9: 1. Bridgelux maintains a tolerance of +/- 0.007 on x and y color coordinates in the CIE 1931 color Space.
Figure 14: Drawing for V8 Packaging Tube Notes for Figure 14: 1. Each tube holds 40 V8 COB arrays. 2. One tube is sealed in an anti-static bag. Four bags are placed in a shipping box. Depending on quantities ordered, a bigger shipping box, containing four boxes may be used to ship products. 3. Each bag and box is to be labeled as shown above. the shipping box are 58.7 x 13.3 x 7.9 cm
Figure 15: Gen. 8 Product Labeling Bridgelux COB arrays have laser markings on the back side of the substrate to help with product identification. In addition to the product identification markings, Bridgelux COB arrays also contain markings for internal Bridgelux manufacturing use only. The image below shows which markings are for customer use and which ones are for Bridgelux internal use only. The Bridgelux internal manufacturing markings are subject to change without notice, however these will not impact the form, function or performance of the COB array. Customer Use- 2D Barcode Scannable barcode provides product part number and other Bridgelux internal production information. Customer Use- Product part number Customer Use- Vf Bin Code included to enable greater luminaire design flexibility. Refer to AN92 for bin code definitions. 30E0800C 83 2F Internal Bin Code
Bridgelux has developed a comprehensive set of application notes and design resources to assist customers in successfully designing with the V Series product family of LED array products. For all available application notes visit www.bridgelux.com. Optical Source Models Optical source models and ray set files are available for all Bridgelux products. Please contact your Bridgelux Sales Representative for more information. MINOR PRODUCT CHANGE POLICY The rigorous qualification testing on products offered by Bridgelux provides performance assurance. Slight cosmetic changes that do not affect form, fit, or function may occur as Bridgelux continues product optimization. CAUTION: CHEMICAL EXPOSURE HAZARD Exposure to some chemicals commonly used in luminaire manufacturing and assembly can cause damage to the LED array. Please consult Bridgelux CAUTION: RISK OF BURN Do not touch the V Series LED array during operation. Allow the array to cool for a sufficient period of time before handling. The V Series LED array may reach elevated temperatures such that could burn skin when touched 3D CAD Models Three dimensional CAD models depicting the product outline of all Bridgelux V Series LED arrays are available in both IGS and STEP formats. Please contact your Bridgelux sales representative for assistance. LM80 LM80 testing has been completed and the LM80 report is now available. Please contact your Bridgelux sales rep- resentatives for LM-80 report. CAUTION CONTACT WITH LIGHT EMITTING SURFACE (LES) Avoid any contact with the LES. Do not touch the LES of the LED array or apply stress to the LES (yellow phosphor resin area). Contact may cause damage to the LED array. Optics and reflectors must not be mounted in contact with the LES (yellow phosphor resin area). Use the mechanical features of the LED array housing and/or edges to locate and secure optical devices as needed. STANDARD TEST CONDITIONS Unless otherwise stated, array testing is performed at the nominal drive current.
About Bridgelux: Bridging Light and Life™ © 2021 Bridgelux, Inc. All rights reserved. Product specifications are subject to change without notice. Bridgelux, the Bridgelux stylized logo design and Vero are registered trademarks, V Series and Decor Series are trademarks of Bridgelux, Inc. All other trademarks are the property of their respective owners. Bridgelux Gen 8 V8 Array Series Product Data Sheet DS411 Rev. E (01/2023)
46410 Fremont Boulevard
Fremont, CA 94538 USA Tel (925) 583-8400 www.bridgelux.com At Bridgelux, we help companies, industries and people experience the power and possibility of light. Since 2002, we’ve designed LED solutions that are high performing, energy efficient, cost effective and easy to integrate. Our focus is on light’s impact on human behavior, delivering products that create better environments, experiences and returns—both experiential and financial. And our patented technology drives new platforms for commercial and industrial luminaires. For more information about the company, please visit bridgelux.com twitter.com/Bridgelux facebook.com/Bridgelux youtube.com/user/Bridgelux linkedin.com/company/bridgelux-inc-_2 WeChat ID: BridgeluxInChina