DS410 BRIDGELUX | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 38
Technical content
Datasheet sections
The V Series™ LED Array products deliver high quality light in a compact and cost-effective solid-state lighting package. These chip on board (CoB) arrays can be efficiently driven up to three times the nominal drive current, enabling design flexibility not previously possible. These high flux density light sources are designed to support a wide range of high quality, low cost directional luminaires and replacement lamps for both interior and exterior commercial and residential applications. The V6 LED Array is available in a variety of electrical, CCT, and CRI combinations providing substantial design flexibility and energy efficiency advantages. Lighting system designs incorporating these LED arrays deliver increased system level efficacy and a longer service life. Typical applications include replacement lamps and task, accent, spot, track, wide area, security, wall packs and down lights. V Series
Features
- Efficacy of 172 lm/W typical for 3000K, 80 CRI
- Compact high flux density light source
- Uniform, high quality illumination
- Minimum 70, 80, and 90 CRI options
- Streamlined thermal path
- ENERGY STAR® / ANSI compliant color binning structure with 2, 3 and 4 SDCM standard
- More energy efficient than incandescent, halogen and fluorescent lamps
- Low voltage DC operation
- Instant light with unlimited dimming
- V f bin code backside marking Benefits
- Enhanced optical control
- Clean white light without pixilation
- High quality, true color reproduction
- Significantly reduced thermal resistance and increased operating temperatures
- Uniform, consistent white light
- Lower operating costs
- Easy to use with daylight and motion detectors to enable increased energy savings
- Reduced maintenance costs
- Environmentally friendly, no disposal issues
The part number designation for Bridgelux V Series LED arrays is explained as follows: 1 2 3 4 – 5 6 7 8 9 10 11 – 12 – 13 14 Product Family CCT Bin Options 2 = 2 SDCM 3 = 3 SDCM 4 = 4 SDCM Flux Indicator 040x = 400lm Minimum CRI C = 70 CRI min. E = 80 CRI min. G = 90 CRI min. H = 97 CRI typ. Array Configuration Nominal CCT 18 = 1,800K 22 = 2,200K 27 = 2,700K 30 = 3,000K 35 = 3,500K 40 = 4,000K 50 = 5,000K 57 = 5,700K 65 = 6,500K BXRE – 30 G 040 0 – A – 8 3 Note: Part number and lot codes are scribed on back of array Gen. 8 Polarity symbols Solder pads White ring around LES Case Temperature (Tc) Measurement Point Fully engineered substrate for consistent thermal, mechanical and optical properties Yellow phosphor Light Emitting Surface (LES) Color Targeting Designator 0 = Cold Targeted 1 = Hot Targeted C = Décor Series Showcase Bridgelux arrays are fully engineered devices that provide consistent thermal and optical performance on an engineered mechanical platform. The V Series arrays are the most compact chip-on-board devices across all of Bridgelux’s LED Array products. The arrays incorporate several features to simplify design integration and assembly. Please visit www.bridgelux.com for more information on the V Series family of products.
The following product configurations are available: Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRE-17E0400-B-8X 1700 80 320 250 220 8.4 2.7 93 BXRE-18G0400-A-8X 1800 90 160 250 220 16.9 2.7 92 BXRE-18G0400-B-8X 1800 90 320 250 220 8.4 2.7 93 BXRE-18G0400-C-8X 1800 90 80 250 220 33.7 2.7 93 BXRE-22E0400-A-8X 2200 80 160 369 324 16.9 2.7 137 BXRE-22E0400-B-8X 2200 80 320 369 324 8.4 2.7 137 BXRE-22E0400-C-8X 2200 80 80 369 324 33.7 2.7 137 BXRE-22G0400-A-8X 2200 90 160 298 262 16.9 2.7 110 BXRE-22G0400-B-8X 2200 90 320 298 262 8.4 2.7 110 BXRE-22G0400-C-8X 2200 90 80 298 262 33.7 2.7 110 BXRE-24G0400-A-8X 2400 90 160 314 283 16.9 2.7 116 BXRE-24G0400-B-8X 2400 90 320 314 283 8.4 2.7 116 BXRE-24G0400-C-8X 2400 90 80 314 283 33.7 2.7 116 BXRE-27E0400-C-8x 2700 80 80 437 384 33.7 2.7 162 BXRE-27E0400-A-8x 2700 80 160 437 384 16.9 2.7 162 BXRE-27E0400-B-8x 2700 80 320 437 384 8.4 2.7 162 BXRE-27E0400-C-8x 2700 80 80 437 384 33.7 2.7 162 BXRE-27G0400-A-8x 2700 90 160 360 317 16.9 2.7 134 BXRE-27G0400-B-8x 2700 90 320 360 317 8.4 2.7 134 BXRE-27G0400-C-8x 2700 90 80 360 317 33.7 2.7 134 BXRE-27G04H0-A-8x 2700 90 160 374 329 16.9 2.7 139 BXRE-27G04H0-B-8x 2700 90 320 374 329 8.4 2.7 139 BXRE-27G04H0-C-8x 2700 90 80 374 329 33.7 2.7 139 BXRE-27H0400-A-8x 2700 97 160 319 281 16.9 2.7 118 BXRE-27H0400-B-8x 2700 97 320 319 281 8.4 2.7 118 BXRE-27H0400-C-8x 2700 97 80 319 281 33.7 2.7 118 BXRE-30C0401-A-8x 3000 70 160 486 428 16.9 2.7 180 BXRE-30C0401-B-8x 3000 70 320 486 428 8.4 2.7 180 BXRE-30C0401-C-8x 3000 70 80 486 428 33.7 2.7 180 BXRE-30E0400-A-8x 3000 80 160 464 408 16.9 2.7 172 BXRE-30E0400-B-8x 3000 80 320 464 408 8.4 2.7 172 BXRE-30E0400-C-8x 3000 80 80 464 408 33.7 2.7 172 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Décor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, Minimum R9 value is 60 for 90 CRI products on 2700K/3000K/3500K and 4000K, it is 50 on 5000K/5700K and 6500K. But for the CRI90 H0 products (higher efficiency CRI90 version), minimum R9 value is 55 on 2700K/3000K/3500K and 4000K. Minimum R9 value for 97 CRI products is 93 on 2700K and 3000K,and it is 85 on 3500K /4000K/5000K and 5700K. Bridgelux maintains a ± 3 tolerance on R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal drive current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test.
The following product configurations are available: Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRE-30G0400-A-8x 3000 90 160 377 331 16.9 2.7 140 BXRE-30G0400-B-8x 3000 90 320 377 331 8.4 2.7 140 BXRE-30G0400-C-8x 3000 90 80 376 331 33.7 2.7 139 BXRE-30G04H0-A-8x 3000 90 160 394 347 16.9 2.7 146 BXRE-30G04H0-B-8x 3000 90 320 394 347 8.4 2.7 146 BXRE-30G04H0-C-8x 3000 90 80 394 347 33.7 2.7 146 BXRE-30H0400-A-8x 3000 97 160 341 300 16.9 2.7 126 BXRE-30H0400-B-8x 3000 97 320 341 300 8.4 2.7 126 BXRE-30H0400-C-8x 3000 97 80 341 300 33.7 2.7 126 BXRE-35E0400-A-8x 3500 80 160 475 418 16.9 2.7 176 BXRE-35E0400-B-8x 3500 80 320 475 418 8.4 2.7 176 BXRE-35E0400-C-8x 3500 80 80 475 418 33.7 2.7 176 BXRE-35G0400-A-8x 3500 90 160 390 343 16.9 2.7 145 BXRE-35G0400-B-8x 3500 90 320 390 343 8.4 2.7 145 BXRE-35G0400-C-8x 3500 90 80 390 343 33.7 2.7 145 BXRE-40C0401-A-8x 4000 70 160 499 440 16.9 2.7 185 BXRE-40C0401-B-8x 4000 70 320 499 440 8.4 2.7 185 BXRE-40C0401-C-8x 4000 70 80 499 440 33.7 2.7 185 BXRE-40E0400-A-8x 4000 80 160 478 420 16.9 2.7 177 BXRE-40E0400-B-8x 4000 80 320 478 420 8.4 2.7 177 BXRE-40E0400-C-8x 4000 80 80 478 420 33.7 2.7 177 BXRE-40G0400-A-8x 4000 90 160 398 351 16.9 2.7 148 BXRE-40G0400-B-8x 4000 90 320 398 351 8.4 2.7 148 BXRE-40G0400-C-8x 4000 90 80 398 351 33.7 2.7 148 BXRE-40H0400-A-8x 4000 97 160 362 318 16.9 2.7 134 BXRE-40H0400-B-8x 4000 97 320 362 318 8.4 2.7 134 BXRE-40H0400-C-8x 4000 97 80 362 318 33.7 2.7 134 BXRE-50C0401-A-8x 5000 70 160 502 442 16.9 2.7 186 BXRE-50C0401-B-8x 5000 70 320 502 442 8.4 2.7 186 BXRE-50C0401-C-8x 5000 70 80 502 442 33.7 2.7 186 BXRE-50E0401-A-8x 5000 80 160 483 425 16.9 2.7 179 BXRE-50E0401-B-8x 5000 80 320 483 425 8.4 2.7 179 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Décor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, Minimum R9 value is 60 for 90 CRI products on 2700K/3000K/3500K and 4000K, it is 50 on 5000K/5700K and 6500K. But for the CRI90 H0 products (higher efficiency CRI90 version), minimum R9 value is 55 on 2700K/3000K/3500K and 4000K. Minimum R9 value for 97 CRI products is 93 on 2700K and 3000K,and it is 85 on 3500K /4000K/5000K and 5700K. Bridgelux maintains a ± 3 tolerance on R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal drive current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test.
Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (Continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRE-50E0401-C-8x 5000 80 80 483 425 33.7 2.7 179 BXRE-50G0401-A-8x 5000 90 160 418 367 16.9 2.7 155 BXRE-50G0401-B-8x 5000 90 320 418 367 8.4 2.7 155 BXRE-50G0401-C-8x 5000 90 80 418 367 33.7 2.7 155 BXRE-57C0401-A-8x 5700 70 160 489 430 16.9 2.7 181 BXRE-57C0401-B-8x 5700 70 320 489 430 8.4 2.7 181 BXRE-57C0401-C-8x 5700 70 80 489 430 33.7 2.7 181 BXRE-57E0401-A-8x 5700 80 160 464 408 16.9 2.7 172 BXRE-57E0401-B-8x 5700 80 320 464 408 8.4 2.7 172 BXRE-57E0401-C-8x 5700 80 80 464 408 33.7 2.7 172 BXRE-65C0401-A-8x 6500 70 160 489 430 16.9 2.7 181 BXRE-65C0401-B-8x 6500 70 320 489 430 8.4 2.7 181 BXRE-65C0401-C-8x 6500 70 80 489 430 33.7 2.7 181 BXRE-65E0401-A-8x 6500 80 160 469 413 16.9 2.7 174 BXRE-65E0401-B-8x 6500 80 320 469 413 8.4 2.7 174 BXRE-65E0401-C-8x 6500 80 80 469 413 33.7 2.7 174 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Décor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, Minimum R9 value is 60 for 90 CRI products on 2700K/3000K/3500K and 4000K, it is 50 on 5000K/5700K and 6500K. But for the CRI90 H0 products (higher efficiency CRI90 version), minimum R9 value is 55 on 2700K/3000K/3500K and 4000K. Minimum R9 value for 97 CRI products is 93 on 2700K and 3000K,and it is 85 on 3500K /4000K/5000K and 5700K. Bridgelux maintains a ± 3 tolerance on R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal drive current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test.
Table 2: Selection Guide, Stabilized DC Performance (Tc = 85°C) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRE-17E0400-B-8X 1700 80 320 225 198 8.2 2.6 86 BXRE-18G0400-A-8X 1800 90 160 225 198 16.6 2.7 85 BXRE-18G0400-B-8X 1800 90 320 225 198 8.2 2.6 86 BXRE-18G0400-C-8X 1800 90 80 225 198 33 2.6 85 BXRE-22E0400-A-8X 2200 80 160 332 292 16.6 2.7 127 BXRE-22E0400-B-8X 2200 80 320 332 292 8.2 2.6 128 BXRE-22E0400-C-8X 2200 80 80 332 292 33 2.6 128 BXRE-22G0400-A-8X 2200 90 160 269 236 16.6 2.7 102 BXRE-22G0400-B-8X 2200 90 320 269 236 8.2 2.6 103 BXRE-22G0400-C-8X 2200 90 80 269 236 33 2.6 103 BXRE-24G0400-A-8X 2400 90 160 283 255 16.6 2.6 107 BXRE-24G0400-B-8X 2400 90 320 283 255 8.2 2.6 107 BXRE-24G0400-C-8X 2400 90 80 283 255 33 2.6 107 BXRE-27E0400-A-8x 2700 80 160 393 346 16.6 2.7 148 BXRE-27E0400-B-8x 2700 80 320 393 346 8.2 2.6 149 BXRE-27E0400-C-8x 2700 80 80 393 346 33.0 2.6 149 BXRE-27G0400-A-8x 2700 90 160 324 285 16.6 2.7 122 BXRE-27G0400-B-8x 2700 90 320 324 285 8.2 2.6 123 BXRE-27G0400-C-8x 2700 90 80 324 285 33.0 2.6 123 BXRE-27G04H0-A-8x 2700 90 160 337 296 16.6 2.7 127 BXRE-27G04H0-B-8x 2700 90 320 337 296 8.2 2.6 128 BXRE-27G04H0-C-8x 2700 90 80 337 296 33.0 2.6 127 BXRE-27H0400-A-8x 2700 97 160 287 253 16.6 2.7 108 BXRE-27H0400-B-8x 2700 97 320 287 253 8.2 2.6 109 BXRE-27H0400-C-8x 2700 97 80 287 253 33.0 2.6 109 BXRE-30C0401-A-8x 3000 70 160 437 385 16.6 2.7 165 BXRE-30C0401-B-8x 3000 70 320 437 385 8.2 2.6 166 BXRE-30C0401-C-8x 3000 70 80 437 385 33.0 2.6 165 BXRE-30E0400-A-8x 3000 80 160 418 367 16.6 2.7 158 BXRE-30E0400-B-8x 3000 80 320 418 367 8.2 2.6 158 BXRE-30E0400-C-8x 3000 80 80 418 367 33.0 2.6 158 BXRE-30G0400-A-8x 3000 90 160 339 298 16.6 2.7 128 Notes for Table 2: 1. Nominal CCT as defined by ANSI C78.377-2011. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Décor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, Minimum R9 value is 60 for 90 CRI products on 2700K/3000K/3500K and 4000K, it is 50 on 5000K/5700K and 6500K. But for the CRI90 H0 products (higher efficiency CRI90 version), minimum R9 value is 55 on 2700K/3000K/3500K and 4000K. Minimum R9 value for 97 CRI products is 93 on 2700K and 3000K,and it is 85 on 3500K /4000K/5000K and 5700K. Bridgelux maintains a ± 3 tolerance on R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
Table 2: Selection Guide, Stabilized DC Performance (Tc = 85°C) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRE-30G0400-B-8x 3000 90 320 339 298 8.2 2.6 129 BXRE-30G0400-C-8x 3000 90 80 338 298 33.0 2.6 128 BXRE-30G04H0-A-8x 3000 90 160 355 312 16.6 2.7 134 BXRE-30G04H0-B-8x 3000 90 320 355 312 8.2 2.6 135 BXRE-30G04H0-C-8x 3000 90 80 355 312 33.0 2.6 134 BXRE-30H0400-A-8x 3000 97 160 307 270 16.6 2.7 116 BXRE-30H0400-B-8x 3000 97 320 307 270 8.2 2.6 117 BXRE-30H0400-C-8x 3000 97 80 307 270 33.0 2.6 116 BXRE-35E0400-A-8x 3500 80 160 427 376 16.6 2.7 161 BXRE-35E0400-B-8x 3500 80 320 427 376 8.2 2.6 162 BXRE-35E0400-C-8x 3500 80 80 427 376 33.0 2.6 162 BXRE-35G0400-A-8x 3500 90 160 351 309 16.6 2.7 133 BXRE-35G0400-B-8x 3500 90 320 351 309 8.2 2.6 133 BXRE-35G0400-C-8x 3500 90 80 351 309 33.0 2.6 133 BXRE-40C0401-A-8x 4000 70 160 450 396 16.6 2.7 170 BXRE-40C0401-B-8x 4000 70 320 450 396 8.2 2.6 171 BXRE-40C0401-C-8x 4000 70 80 450 396 33.0 2.6 170 BXRE-40E0400-A-8x 4000 80 160 430 378 16.6 2.7 162 BXRE-40E0400-B-8x 4000 80 320 430 378 8.2 2.6 163 BXRE-40E0400-C-8x 4000 80 80 430 378 33.0 2.6 163 BXRE-40H0400-A-8x 4000 97 160 326 286 16.6 2.7 121 BXRE-40H0400-B-8x 4000 97 320 326 286 8.2 2.6 125 BXRE-40H0400-C-8x 4000 97 80 326 286 33.0 2.6 125 BXRE-40G0400-A-8x 4000 90 160 359 316 16.6 2.7 135 BXRE-40G0400-B-8x 4000 90 320 359 316 8.2 2.6 136 BXRE-40G0400-C-8x 4000 90 80 359 316 33.0 2.6 136 BXRE-50C0401-A-8x 5000 70 160 452 398 16.6 2.7 170 BXRE-50C0401-B-8x 5000 70 320 452 398 8.2 2.6 172 BXRE-50C0401-C-8x 5000 70 80 452 398 33.0 2.6 171 BXRE-50E0401-A-8x 5000 80 160 435 383 16.6 2.7 164 BXRE-50E0401-B-8x 5000 80 320 435 383 8.2 2.6 165 BXRE-50E0401-C-8x 5000 80 80 435 383 33.0 2.6 165 BXRE-50G0401-A-8x 5000 90 160 376 331 16.6 2.7 142 Notes for Table 2: 1. Nominal CCT as defined by ANSI C78.377-2011. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Décor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, Minimum R9 value is 60 for 90 CRI products on 2700K/3000K/3500K and 4000K, it is 50 on 5000K/5700K and 6500K. But for the CRI90 H0 products (higher efficiency CRI90 version), minimum R9 value is 55 on 2700K/3000K/3500K and 4000K. Minimum R9 value for 97 CRI products is 93 on 2700K and 3000K,and it is 85 on 3500K /4000K/5000K and 5700K. Bridgelux maintains a ± 3 tolerance on R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
Table 2: Selection Guide, Stabilized DC Performance (Tc = 85°C) (Continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRE-50G0401-B-8x 5000 90 320 376 331 8.2 2.6 143 BXRE-50G0401-C-8x 5000 90 80 376 331 33.0 2.6 142 BXRE-57C0401-A-8x 5700 70 160 440 387 16.6 2.7 166 BXRE-57C0401-B-8x 5700 70 320 440 387 8.2 2.6 167 BXRE-57C0401-C-8x 5700 70 80 440 387 33.0 2.6 166 BXRE-57E0401-A-8x 5700 80 160 418 367 16.6 2.7 158 BXRE-57E0401-B-8x 5700 80 320 418 367 8.2 2.6 158 BXRE-57E0401-C-8x 5700 80 80 418 367 33.0 2.6 158 BXRE-65C0401-A-8x 6500 70 160 440 387 16.6 2.7 166 BXRE-65C0401-B-8x 6500 70 320 440 387 8.2 2.6 167 BXRE-65C0401-C-8x 6500 70 80 440 387 33.0 2.6 166 BXRE-65E0401-A-8x 6500 80 160 423 372 16.6 2.7 159 BXRE-65E0401-B-8x 6500 80 320 423 372 8.2 2.6 160 BXRE-65E0401-C-8x 6500 80 80 423 372 33.0 2.6 160 Notes for Table 2: 1. Nominal CCT as defined by ANSI C78.377-2011. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Décor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, Minimum R9 value is 60 for 90 CRI products on 2700K/3000K/3500K and 4000K, it is 50 on 5000K/5700K and 6500K. But for the CRI90 H0 products (higher efficiency CRI90 version), minimum R9 value is 55 on 2700K/3000K/3500K and 4000K. Minimum R9 value for 97 CRI products is 93 on 2700K and 3000K,and it is 85 on 3500K /4000K/5000K and 5700K. Bridgelux maintains a ± 3 tolerance on R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
European Product Registry for Energy Labeling The European Product Registry for Energy Labeling (EPREL) is defined in the EU Regulation 2017/1369 to provide import- ant energy efficiency information to consumers. Together with Energy Labeling Regulation ELR (EU) 2019/2015 which was amended by regulation (EU) 2021/340 for energy labelling of light sources, manufacturers are required to declare an ener- gy class based on key technical specifications from each of their product and register it in an open data base managed by EPREL It is now a legal requirement for a vendor of light sources to upload information about their products into the EPREL database before placing these products on the market in the EU. Table 3 below provides a list of part numbers that are in compliance with ELR and are currently listed in the EPREL data- base. At Bridgelux, we are fully committed to supplying products that are compliant with pertinent laws, rules, and obligation imposed by relevant government bodies including the European Energy Labeling regulation. Customers can use these products with full confidence for any projects that fall under the ELR. Table 3: Part numbers registered in European Product Registry for Energy Labeling PART NUMBER1 CCT (K) CRI Current2 (mA) Vf (V) Useful flux3 (Φuse) at 85C (lm) Pow- er (W) Efficacy (lm/W) Energy efficiency class4 Regis- tration No URL to Product Information Sheet in EPREL Database Notes for Table 3: 1. All device listed here must be disposed as e-waste upon its end of life according to local country guideline in each country. 2. For information on performance values at alternative drive conditions. please refer to the Product Selection Guide, Absolute Maximum Rating Table and Performance Curves in this data sheet. 3. For a definition of useful luminous flux (ΦΦuse), please see the ELR regulations at https:/ /tinyurl.com/4b6zvt4m. 4. EPREL requires an arrow symbol containing the letter of the energy efficiency class to be displayed. on technical promotional material. Refer to this energy efficiency class column for specific energy efficiency class on each part number.
European Product Registry for Energy Labeling Table 3: Part numbers registered in European Product Registry for Energy Labeling (Continued) PART NUMBER1 CCT (K) CRI Current2 (mA) Vf (V) Useful flux3 (Φuse) at 85C (lm) Pow- er (W) Efficacy (lm/W) Energy efficiency class4 Regis- tration No URL to Product Information Sheet in EPREL Database Notes for Table 3: 1. All device listed here must be disposed as e-waste upon its end of life according to local country guideline in each country. 2. For information on performance values at alternative drive conditions. please refer to the Product Selection Guide, Absolute Maximum Rating Table and Performance Curves in this data sheet. 3. For a definition of useful luminous flux (ΦΦuse), please see the ELR regulations at https:/ /tinyurl.com/4b6zvt4m. 4. EPREL requires an arrow symbol containing the letter of the energy efficiency class to be displayed. on technical promotional material. Refer to this energy efficiency class column for specific energy efficiency class on each part number.
European Product Registry for Energy Labeling Table 3: Part numbers registered in European Product Registry for Energy Labeling (Continued) PART NUMBER1 CCT (K) CRI Current2 (mA) Vf (V) Useful flux3 (Φuse) at 85C (lm) Pow- er (W) Efficacy (lm/W) Energy efficiency class4 Regis- tration No URL to Product Information Sheet in EPREL Database Notes for Table 3: 1. All device listed here must be disposed as e-waste upon its end of life according to local country guideline in each country. 2. For information on performance values at alternative drive conditions. please refer to the Product Selection Guide, Absolute Maximum Rating Table and Performance Curves in this data sheet. 3. For a definition of useful luminous flux (ΦΦuse), please see the ELR regulations at https:/ /tinyurl.com/4b6zvt4m. 4. EPREL requires an arrow symbol containing the letter of the energy efficiency class to be displayed. on technical promotional material. Refer to this energy efficiency class column for specific energy efficiency class on each part number.
Performance at Commonly Used Drive Currents V Series LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. V Series may also be driven at other drive currents dependent on specific application design requirements. The performance at any drive current can be derived from the current vs. voltage characteristics shown in Figures 1, 2 & 3 and the flux vs. current characteristics shown in Figures 4, 5 & 6. The performance at commonly used drive currents is summarized in Table 4. Table 4: Product Performance at Commonly Used Drive Currents Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRE-17E0400-B-8X 80 80 8 0.6 64 58 108 160 8.2 1.3 128 115 98 320 8.4 2.7 250 225 93 480 8.7 4.2 365 329 87 800 9.2 7.3 576 519 79 1000 9.4 9.4 694 625 74 BXRE-18G0400-A-8X 90 40 16.0 0.6 64 58 100 80 16.3 1.3 128 115 98 160 16.9 2.7 250 225 92 240 17.4 4.2 366 329 88 400 18.3 7.3 576 518 79 500 18.8 9.4 695 625 74 BXRE-18G0400-B-8X 90 80 8.0 0.6 64 58 100 160 8.2 1.3 128 115 98 320 8.4 2.7 250 225 93 480 8.7 4.2 366 329 88 800 9.2 7.3 576 518 79 1000 9.4 9.4 695 625 74 BXRE-18G0400-C-8X 90 20 32.0 0.6 64 58 100 40 32.6 1.3 128 115 98 80 33.7 2.7 250 225 93 120 34.8 4.2 366 329 88 200 36.6 7.3 576 518 79 250 37.6 9.4 695 625 74 BXRE-22E0400-A-8X 80 40 16.0 0.6 95 86 159 80 16.3 1.3 189 170 145 160 16.9 2.7 369 332 137 240 17.4 4.2 539 486 128 400 18.3 7.3 850 766 116 500 18.8 9.4 1025 923 109 BXRE-22E0400-B-8X 80 80 8.0 0.6 95 86 159 160 8.2 1.3 189 170 145 320 8.4 2.7 369 332 137 480 8.7 4.2 539 486 128 800 9.2 7.3 850 766 116 1000 9.4 9.4 1025 923 109 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRE-22E0400-C-8X 80 20 32.0 0.6 95 86 159 40 32.6 1.3 189 170 145 80 33.7 2.7 369 332 137 120 34.8 4.2 539 486 128 200 36.6 7.3 850 766 116 250 37.6 9.4 1025 923 109 BXRE-22G0400-A-8X 90 40 16.0 0.6 77 69 128 80 16.3 1.3 153 138 118 160 16.9 2.7 298 269 110 240 17.4 4.2 436 393 104 400 18.3 7.3 687 619 94 500 18.8 9.4 829 746 88 BXRE-22G0400-B-8X 90 80 8.0 0.6 77 69 128 160 8.2 1.3 153 138 118 320 8.4 2.7 298 269 110 480 8.7 4.2 436 393 104 800 9.2 7.3 687 619 94 1000 9.4 9.4 829 746 88 BXRE-22G0400-C-8X 90 20 32.0 0.6 77 69 128 40 32.6 1.3 153 138 118 80 33.7 2.7 298 269 110 120 34.8 4.2 436 393 104 200 36.6 7.3 687 619 94 250 37.6 9.4 829 746 88 BXRE-24G0400-A-8x 90 40 16 0.6 81 73 126 80 16.3 1.3 161 145 123 160 16.9 2.7 314 283 116 240 17.4 4.2 459 413 110 400 18.3 7.3 724 651 99 500 18.8 9.4 872 785 93 BXRE-24G0400-B-8x 90 80 8 0.6 81 73 126 160 8.2 1.3 161 145 123 320 8.4 2.7 314 283 117 480 8.7 4.2 459 413 110 800 9.2 7.4 724 651 98 1000 9.4 9.4 872 785 93 BXRE-24G0400-C-8x 90 20 32 0.6 81 73 126 40 32.6 1.3 160 144 123 80 33.7 2.7 313 282 116 120 34.8 4.2 458 412 110 200 36.6 7.3 722 650 99 250 37.6 9.4 870 783 93 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRE-27E0400-A-8x 80 40 16.0 0.6 112 101 176 80 16.3 1.3 224 201 171 160 16.9 2.7 437 393 162 240 17.4 4.2 639 575 153 400 18.3 7.3 1007 906 138 500 18.8 9.4 1214 1092 129 BXRE-27E0400-B-8x 80 80 8.0 0.6 112 101 176 160 8.2 1.3 224 201 171 320 8.4 2.7 437 393 162 480 8.7 4.2 639 575 153 800 9.2 7.3 1007 906 138 1000 9.4 9.4 1214 1092 129 BXRE-27E0400-C-8x 80 20 32.0 0.6 112 101 176 40 32.6 1.3 224 201 171 80 33.7 2.7 437 393 162 120 34.8 4.2 639 575 153 200 36.6 7.3 1007 906 138 250 37.6 9.4 1214 1092 129 BXRE-27G0400-A-8x 90 40 16.0 0.6 93 84 145 80 16.3 1.3 184 166 141 160 16.9 2.7 360 324 134 240 17.4 4.2 527 474 126 400 18.3 7.3 831 748 113 500 18.8 9.4 1001 901 106 BXRE-27G0400-B-8x 90 80 8.0 0.6 93 84 145 160 8.2 1.3 184 166 141 320 8.4 2.7 360 324 134 480 8.7 4.2 527 474 126 800 9.2 7.3 831 748 113 1000 9.4 9.4 1001 901 106 BXRE-27G0400-C-8x 90 20 32.0 0.6 93 84 145 40 32.6 1.3 184 166 141 80 33.7 2.7 360 324 134 120 34.8 4.2 527 474 126 200 36.6 7.3 831 748 113 250 37.6 9.4 1001 901 106 BXRE-27G04H0-A-8x 90 40 16.0 0.6 96 87 150 80 16.3 1.3 191 172 147 160 16.9 2.7 374 337 139 240 17.4 4.2 547 492 131 400 18.3 7.3 862 776 118 500 18.8 9.4 1039 935 110 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRE-27G04H0-B-8x 90 80 8.0 0.6 96 87 150 160 8.2 1.3 191 172 147 320 8.4 2.7 374 337 139 480 8.7 4.2 547 492 131 800 9.2 7.3 862 776 118 1000 9.4 9.4 1039 935 110 BXRE-27G04H0-C-8x 90 20 32.0 0.6 96 87 150 40 32.6 1.3 191 172 147 80 33.7 2.7 374 337 139 120 34.8 4.2 547 492 131 200 36.6 7.3 862 776 118 250 37.6 9.4 1039 935 110 BXRE-27H0400-A-8x 97 40 16.0 0.6 82 74 128 80 16.3 1.3 163 147 125 160 16.9 2.7 319 287 118 240 17.4 4.2 467 420 112 400 18.3 7.3 736 663 101 500 18.8 9.4 887 799 94 BXRE-27H0400-B-8x 97 80 8.0 0.6 82 74 128 160 8.2 1.3 163 147 125 320 8.4 2.7 319 287 118 480 8.7 4.2 467 420 112 800 9.2 7.3 736 663 101 1000 9.4 9.4 887 799 94 BXRE-27H0400-C-8x 97 20 32.0 0.6 82 74 128 40 32.6 1.3 163 147 125 80 33.7 2.7 319 287 118 120 34.8 4.2 467 420 112 200 36.6 7.3 736 663 101 250 37.6 9.4 887 799 94 BXRE-30C0401-A-8x 70 40 16.0 0.6 125 113 195 80 16.3 1.3 249 224 191 160 16.9 2.7 486 437 180 240 17.4 4.2 711 639 170 400 18.3 7.3 1120 1008 153 500 18.8 9.4 1350 1215 144 BXRE-30C0401-B-8x 70 80 8.0 0.6 125 113 195 160 8.2 1.3 249 224 191 320 8.4 2.7 486 437 180 480 8.7 4.2 711 639 170 800 9.2 7.3 1120 1008 153 1000 9.4 9.4 1350 1215 144 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRE-30C0401-C-8x 70 20 32.0 0.6 125 113 195 40 32.6 1.3 249 224 191 80 33.7 2.7 486 437 180 120 34.8 4.2 711 639 170 200 36.6 7.3 1120 1008 153 250 37.6 9.4 1350 1215 144 BXRE-30E0400-A-8x 80 40 16.0 0.6 120 108 187 80 16.3 1.3 238 214 182 160 16.9 2.7 464 418 172 240 17.4 4.2 679 611 163 400 18.3 7.3 1070 963 146 500 18.8 9.4 1290 1161 137 BXRE-30E0400-B-8x 80 80 8.0 0.6 120 108 187 160 8.2 1.3 238 214 182 320 8.4 2.7 464 418 172 480 8.7 4.2 679 611 163 800 9.2 7.3 1070 963 146 1000 9.4 9.4 1290 1161 137 BXRE-30E0400-C-8x 80 20 32.0 0.6 120 108 187 40 32.6 1.3 238 214 182 80 33.7 2.7 464 418 172 120 34.8 4.2 679 611 163 200 36.6 7.3 1070 963 146 250 37.6 9.4 1290 1161 137 BXRE-30G0400-A-8x 90 40 16.0 0.6 97 87 151 80 16.3 1.3 193 174 148 160 16.9 2.7 377 339 140 240 17.4 4.2 551 496 132 400 18.3 7.3 869 782 119 500 18.8 9.4 1047 942 111 BXRE-30G0400-B-8x 90 80 8.0 0.6 97 87 151 160 8.2 1.3 193 174 148 320 8.4 2.7 377 339 140 480 8.7 4.2 551 496 132 800 9.2 7.3 869 782 119 1000 9.4 9.4 1047 942 111 BXRE-30G0400-C-8x 90 20 32.0 0.6 97 87 151 40 32.6 1.3 192 173 147 80 33.7 2.7 376 338 139 120 34.8 4.2 550 495 132 200 36.6 7.3 867 780 118 250 37.6 9.4 1045 940 111 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRE-30G04H0-A-8x 90 40 16.0 0.6 102 91 159 80 16.3 1.3 202 182 155 160 16.9 2.7 394 355 146 240 17.4 4.2 577 519 138 400 18.3 7.3 910 819 124 500 18.8 9.4 1096 986 117 BXRE-30G04H0-B-8x 90 80 8.0 0.6 102 91 159 160 8.2 1.3 202 182 155 320 8.4 2.7 394 355 146 480 8.7 4.2 577 519 138 800 9.2 7.3 910 819 124 1000 9.4 9.4 1096 986 117 BXRE-30G04H0-C-8x 90 20 32.0 0.6 102 91 159 40 32.6 1.3 202 182 155 80 33.7 2.7 394 355 146 120 34.8 4.2 577 519 138 200 36.6 7.3 910 819 124 250 37.6 9.4 1096 986 117 BXRE-30H0400-A-8x 97 40 16.0 0.6 88 79 137 80 16.3 1.3 175 157 134 160 16.9 2.7 341 307 126 240 17.4 4.2 499 449 120 400 18.3 7.3 787 708 107 500 18.8 9.4 948 853 101 BXRE-30H0400-B-8x 97 80 8.0 0.6 88 79 137 160 8.2 1.3 175 157 134 320 8.4 2.7 341 307 126 480 8.7 4.2 499 449 120 800 9.2 7.3 787 708 107 1000 9.4 9.4 948 853 101 BXRE-30H0400-C-8x 97 20 32.0 0.6 88 79 137 40 32.6 1.3 175 157 134 80 33.7 2.7 341 307 126 120 34.8 4.2 499 449 120 200 36.6 7.3 787 708 107 250 37.6 9.4 948 853 101 BXRE-35E0400-A-8x 80 40 16.0 0.6 122 110 191 80 16.3 1.3 243 219 186 160 16.9 2.7 475 427 176 240 17.4 4.2 695 625 167 400 18.3 7.3 1095 986 150 500 18.8 9.4 1320 1188 140 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRE-35E0400-B-8x 80 80 8.0 0.6 122 110 191 160 8.2 1.3 243 219 186 320 8.4 2.7 475 427 176 480 8.7 4.2 695 625 167 800 9.2 7.3 1095 986 150 1000 9.4 9.4 1320 1188 140 BXRE-35E0400-C-8x 80 20 32.0 0.6 122 110 191 40 32.6 1.3 243 219 186 80 33.7 2.7 475 427 176 120 34.8 4.2 695 625 167 200 36.6 7.3 1095 986 150 250 37.6 9.4 1320 1188 140 BXRE-35G0400-A-8x 90 40 16.0 0.6 101 90 157 80 16.3 1.3 200 180 153 160 16.9 2.7 390 351 145 240 17.4 4.2 571 514 137 400 18.3 7.3 900 810 123 500 18.8 9.4 1085 976 115 BXRE-35G0400-B-8x 90 80 8.0 0.6 101 90 157 160 8.2 1.3 200 180 153 320 8.4 2.7 390 351 145 480 8.7 4.2 571 514 137 800 9.2 7.3 900 810 123 1000 9.4 9.4 1085 976 115 BXRE-35G0400-C-8x 90 20 32.0 0.6 101 90 157 40 32.6 1.3 200 180 153 80 33.7 2.7 390 351 145 120 34.8 4.2 571 514 137 200 36.6 7.3 900 810 123 250 37.6 9.4 1085 976 115 BXRE-40C0401-A-8x 70 40 16.0 0.6 129 116 201 80 16.3 1.3 256 230 196 160 16.9 2.7 499 450 185 240 17.4 4.2 730 657 175 400 18.3 7.3 1152 1037 157 500 18.8 9.4 1388 1249 148 BXRE-40C0401-B-8x 70 80 8.0 0.6 129 116 201 160 8.2 1.3 256 230 196 320 8.4 2.7 499 450 185 480 8.7 4.2 730 657 175 800 9.2 7.3 1152 1037 157 1000 9.4 9.4 1388 1249 148 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRE-40C0401-C-8x 70 20 32.0 0.6 129 116 201 40 32.6 1.3 256 230 196 80 33.7 2.7 499 450 185 120 34.8 4.2 730 657 175 200 36.6 7.3 1152 1037 157 250 37.6 9.4 1388 1249 148 BXRE-40E0400-A-8x 80 40 16.0 0.6 123 111 192 80 16.3 1.3 245 220 187 160 16.9 2.7 478 430 177 240 17.4 4.2 699 629 168 400 18.3 7.3 1102 991 150 500 18.8 9.4 1327 1195 141 BXRE-40E0400-B-8x 80 80 8.0 0.6 123 111 192 160 8.2 1.3 245 220 187 320 8.4 2.7 478 430 177 480 8.7 4.2 699 629 168 800 9.2 7.3 1102 991 150 1000 9.4 9.4 1327 1195 141 BXRE-40E0400-C-8x 80 20 32.0 0.6 123 111 192 40 32.6 1.3 245 220 187 80 33.7 2.7 478 430 177 120 34.8 4.2 699 629 168 200 36.6 7.3 1102 991 150 250 37.6 9.4 1327 1195 141 BXRE-40G0400-A-8x 90 40 16.0 0.6 103 92 160 80 16.3 1.3 204 184 156 160 16.9 2.7 398 359 148 240 17.4 4.2 583 525 140 400 18.3 7.3 919 827 126 500 18.8 9.4 1107 997 118 BXRE-40G0400-B-8x 90 80 8.0 0.6 103 92 160 160 8.2 1.3 204 184 156 320 8.4 2.7 398 359 148 480 8.7 4.2 583 525 140 800 9.2 7.3 919 827 126 1000 9.4 9.4 1107 997 118 BXRE-40G0400-C-8x 90 20 32.0 0.6 103 92 160 40 32.6 1.3 204 184 156 80 33.7 2.7 398 359 148 120 34.8 4.2 583 525 140 200 36.6 7.3 919 827 126 250 37.6 9.4 1107 997 118 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRE-40H0400-A-8x 97 40 16.0 0.6 94 84 156 80 16.3 1.3 186 167 143 160 16.9 2.7 362 326 134 240 17.4 4.2 530 477 126 400 18.3 7.3 835 752 114 500 18.8 9.4 1006 907 107 BXRE-40H0400-B-8x 97 80 8.0 0.6 94 84 156 160 8.2 1.3 186 167 143 320 8.4 2.7 362 326 134 480 8.7 4.2 530 477 126 800 9.2 7.3 835 752 114 1000 9.4 9.4 1006 907 107 BXRE-40H0400-C-8x 97 20 32.0 0.6 94 84 156 40 32.6 1.3 186 167 143 80 33.7 2.7 362 326 134 120 34.8 4.2 530 477 126 200 36.6 7.3 835 752 114 250 37.6 9.4 1006 907 107 BXRE-50C0401-A-8x 70 40 16.0 0.6 129 116 202 80 16.3 1.3 257 231 197 160 16.9 2.7 502 452 186 240 17.4 4.2 734 661 176 400 18.3 7.3 1158 1042 158 500 18.8 9.4 1396 1256 148 BXRE-50C0401-B-8x 70 80 8.0 0.6 129 116 202 160 8.2 1.3 257 231 197 320 8.4 2.7 502 452 186 480 8.7 4.2 734 661 176 800 9.2 7.3 1158 1042 158 1000 9.4 9.4 1396 1256 148 BXRE-50C0401-C-8x 70 20 32.0 0.6 129 116 202 40 32.6 1.3 257 231 197 80 33.7 2.7 502 452 186 120 34.8 4.2 734 661 176 200 36.6 7.3 1158 1042 158 250 37.6 9.4 1396 1256 148 BXRE-50E0401-A-8x 80 40 16.0 0.6 124 112 194 80 16.3 1.3 247 223 190 160 16.9 2.7 483 435 179 240 17.4 4.2 707 636 169 400 18.3 7.3 1114 1003 152 500 18.8 9.4 1343 1208 143 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRE-50E0401-B-8x 80 80 8.0 0.6 124 112 194 160 8.2 1.3 247 223 190 320 8.4 2.7 483 435 179 480 8.7 4.2 707 636 169 800 9.2 7.3 1114 1003 152 1000 9.4 9.4 1343 1208 143 BXRE-50E0401-C-8x 80 20 32.0 0.6 124 112 194 40 32.6 1.3 247 223 190 80 33.7 2.7 483 435 179 120 34.8 4.2 707 636 169 200 36.6 7.3 1114 1003 152 250 37.6 9.4 1343 1208 143 BXRE-50G0401-A-8x 90 40 16.0 0.6 108 97 168 80 16.3 1.3 214 192 164 160 16.9 2.7 418 376 155 240 17.4 4.2 611 550 146 400 18.3 7.3 963 867 132 500 18.8 9.4 1161 1045 123 BXRE-50G0401-B-8x 90 80 8.0 0.6 108 97 168 160 8.2 1.3 214 192 164 320 8.4 2.7 418 376 155 480 8.7 4.2 611 550 146 800 9.2 7.3 963 867 132 1000 9.4 9.4 1161 1045 123 BXRE-50G0401-C-8x 90 20 32.0 0.6 108 97 168 40 32.6 1.3 214 192 164 80 33.7 2.7 418 376 155 120 34.8 4.2 611 550 146 200 36.6 7.3 963 867 132 250 37.6 9.4 1161 1045 123 BXRE-57C0401-A-8x 70 40 16.0 0.6 126 113 196 80 16.3 1.3 250 225 192 160 16.9 2.7 489 440 181 240 17.4 4.2 715 643 171 400 18.3 7.3 1127 1014 154 500 18.8 9.4 1358 1222 144 BXRE-57C0401-B-8x 70 80 8.0 0.6 126 113 196 160 8.2 1.3 250 225 192 320 8.4 2.7 489 440 181 480 8.7 4.2 715 643 171 800 9.2 7.3 1127 1014 154 1000 9.4 9.4 1358 1222 144 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRE-57C0401-C-8x 70 20 32.0 0.6 126 113 196 40 32.6 1.3 250 225 192 80 33.7 2.7 489 440 181 120 34.8 4.2 715 643 171 200 36.6 7.3 1127 1014 154 250 37.6 9.4 1358 1222 144 BXRE-57E0401-A-8x 80 40 16.0 0.6 120 108 187 80 16.3 1.3 238 214 182 160 16.9 2.7 464 418 172 240 17.4 4.2 679 611 163 400 18.3 7.3 1070 963 146 500 18.8 9.4 1290 1161 137 BXRE-57E0401-B-8x 80 80 8.0 0.6 120 108 187 160 8.2 1.3 238 214 182 320 8.4 2.7 464 418 172 480 8.7 4.2 679 611 163 800 9.2 7.3 1070 963 146 1000 9.4 9.4 1290 1161 137 BXRE-57E0401-C-8x 80 20 32.0 0.6 120 108 187 40 32.6 1.3 238 214 182 80 33.7 2.7 464 418 172 120 34.8 4.2 679 611 163 200 36.6 7.3 1070 963 146 250 37.6 9.4 1290 1161 137 BXRE-65C0401-A-8x 70 40 16.0 0.6 126 113 196 80 16.3 1.3 250 225 192 160 16.9 2.7 489 440 181 240 17.4 4.2 715 643 171 400 18.3 7.3 1127 1014 154 500 18.8 9.4 1358 1222 144 BXRE-65C0401-B-8x 70 80 8.0 0.6 126 113 196 160 8.2 1.3 250 225 192 320 8.4 2.7 489 440 181 480 8.7 4.2 715 643 171 800 9.2 7.3 1127 1014 154 1000 9.4 9.4 1358 1222 144 BXRE-65C0401-C-8x 70 20 32.0 0.6 126 113 196 40 32.6 1.3 250 225 192 80 33.7 2.7 489 440 181 120 34.8 4.2 715 643 171 200 36.6 7.3 1127 1014 154 250 37.6 9.4 1358 1222 144 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRE-65E0401-A-8x 80 40 16.0 0.6 121 109 189 80 16.3 1.3 240 216 184 160 16.9 2.7 469 423 174 240 17.4 4.2 687 618 165 400 18.3 7.3 1083 974 148 500 18.8 9.4 1305 1174 139 BXRE-65E0401-B-8x 80 80 8.0 0.6 121 109 189 160 8.2 1.3 240 216 184 320 8.4 2.7 469 423 174 480 8.7 4.2 687 618 165 800 9.2 7.3 1083 974 148 1000 9.4 9.4 1305 1174 139 BXRE-65E0401-C-8x 80 20 32.0 0.6 121 109 189 40 32.6 1.3 240 216 184 80 33.7 2.7 469 423 174 120 34.8 4.2 687 618 165 200 36.6 7.3 1083 974 148 250 37.6 9.4 1305 1174 139 Notes for Table 4: 1. Alternate drive currents in Table 4 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Electrical Characteristics
Table 5: Electrical Characteristics Part Number Drive Current (mA) Forward Voltage Pulsed, Tc = 25ºC (V) 1, 2, 3, 8 Typical Coefficient of Forward Voltage4 ∆Vf/∆Tc (mV/ºC) Typical Thermal Resistance Junction to Case5,6 Rj-c (ºC/W) Driver Selection Voltages7 (V) Minimum Typical Maximum Vf Min. Hot Tc = 105ºC (V) Vf Max. Cold Tc = -40ºC (V) BXRE-xxx040x-A-8x BXRE-xxx040x-B-8x BXRE-xxx040x-C-8x Notes for Table 5: 1. Parts are tested in pulsed conditions, Tc = 25°C. Pulse width is 10ms. 2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance. 3. Bridgelux maintains a tester tolerance of ± 0.10V on forward voltage measurements. 4. Typical coefficient of forward voltage tolerance is ± 0.1mV for nominal current. 5. Thermal resistance values are based from test data of a 3000K 80 CRI product. 6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal interface material used during testing is not included in the thermal resistance value. 7. Vf min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design and selection over the operating range of the product. 8. This product has been designed and manufactured per IEC 62031:2018. This product has passed dielectric withstand voltage testing at 1140 V. The working voltage designated for the insulation is 70V d.c. The maximum allowable voltage across the array must be determined in the end product application.
Table 6: Eye Safety Risk Group (RG) Classifications Part Number Drive Current (mA) CCT4 2700K/3000K 4000K 5000K2 6500K3 BXRE-xxx040x-A-8x
280 RG1 RG1 RG1 RG1
390 RG1 RG1 RG1 RG2
500 RG1 RG1 RG2 RG2
565 RG1 RG1 RG1 RG1
785 RG1 RG1 RG1 RG2
1000 RG1 RG1 RG2 RG2
140 RG1 RG1 RG1 RG1
190 RG1 RG1 RG1 RG2
250 RG1 RG1 RG2 RG2
Notes for Table 6: 1. Eye safety classification for the use of Bridgelux V Series LED arrays is in accordance with specification IEC/TR 62778: Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires. 2. For products classified as RG2 at 5000K Ethr= 1530 lx. 3. For products classified as RG2 at 6500K, Ethr= 1170 lx. 4. Please contact your Bridgelux sales representative for Ethr values at specific drive currents and CCTs not listed.
LED Junction Temperature (Tj) 150°C Storage Temperature -40°C to +105°C Operating Case Temperature1 (Tc) 105°C Soldering Temperature2 300°C or lower for a maximum of 6 seconds BXRE-xxx040x-A-8x BXRE-xxx040x-B-8x BXRE-xxx040x-C-8x Maximum Drive Current3 500 mA 1000 mA 250 mA Maximum Peak Pulsed Drive Current4 560 mA 1120 mA 280 mA Maximum Reverse Voltage5 -30V -15V -60V Notes for Table 7: 1. For IEC 62717 requirement, please consult your Bridgelux sales representative. 2. Refer to Bridgelux Application Note AN101: Handling and Assembly of Bridgelux V Series LED Arrays. 3. Arrays may be driven at higher currents however lumen maintenance may be reduced and warranty will not apply. 4. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed current specified. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures. 5. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating provided for reference only. Table 7: Maximum Ratings
Figure 10: Typical Color Spectrum Notes for Figure 10: 1. Color spectra measured at nominal current for Tj = Tc = 25°C. 2. Color spectra shown is 2700K and 80 CRI. 3. Color spectra shown is 3000K and 80 CRI. 4. Color spectra shown is 4000K and 80 CRI. 5. Color spectra shown is 5000K and 70 CRI. 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 400 450 500 550 600 650 700 750 800 Relative Spectral Power Distribution Wavelength (nm) 27E 30E 40E 50C
Figure 13: V6 LED Array Notes for Figure 13: 1. Drawings are not to scale. 2. Drawing dimensions are in millimeters. 3. Solder pads are labeled “+” and “-“ to denote positive and negative polarity, respectively. 4. Unless otherwise specified, tolerances are ±0.1mm. 5. Refer to Application Notes AN101 for product handling, mounting and heat sink recommendations. 6. The optical center of the LED Array is nominally defined by the mechanical center of the array to a tolerance of ± 0.2mm. 7. Bridgelux maintains a flatness of 0.10mm across the mounting surface of the array.
Figure 14: Graph of Warm and Neutral White Test Bins in xy Color Space Bin Code 1750K 1800K 2200K 2400K 2700K 3000K 3500K 4000K ANSI Bin (for reference only) - - (2207K-2309K) (2300K-2500K) (2580K - 2870K) (2870K - 3220K) (3220K - 3710K) (3710K - 4260K) 82 (2 SDCM) - - (2207K-2309K) (2336K-2454K) (2674K - 2769K) (2995K - 3107K) (3404K - 3548K) (3895K - 4081K) 83 (3 SDCM) - - (2224K-2291K) (2355K-2433K) (2651K - 2794K) (2968K - 3136K) (3369K - 3586K) (3851K - 4130K) Center Point Table 8: Warm and Neutral White xy Bin Coordinates and Associated Typical CCT Note: Pulsed Test Conditions, Tc = 25°C Table 9: Cool White xy Bin Coordinates and Associated Typical CCT(product is hot targeted to Tc = 85°C) Figure 15: Graph of Cool White Test Bins in xy Color Space Bin Code 5000K 5700K 6500K ANSI Bin (for reference only) (4745K - 5311K) (5312K - 6022K) (6022K - 7042K) 84 (4 SDCM) (4801K - 5282K) ((5395K - 5970K() (6200K - 6910K) 83 (3 SDCM) (4835K - 5215K) ((5460K - 5891K() (6279K - 6811K) 0.3 0.31 0.32 0.33 0.34 0.35 0.36 0.37 0.38 0.39 Y X
4 SDCM
3 SDCM
Note: Pulsed Test Conditions, Tc = 25°C Note for Tables 8-9: 1. Bridgelux maintains a tolerance of +/- 0.007 on x and y color coordinates in the CIE 1931 color Space.
Figure 16: Drawing for V6 Packaging Tube Notes for Figure 16: 1. Each tube holds 40 V6 COB arrays. 2. One tube is sealed in an anti-static bag. Four bags are placed in a shipping box. Depending on quantities ordered, a bigger shipping box, containing four boxes may be used to ship products. 3. Each bag and box is to be labeled as shown above. the shipping box are 58.7 x 13.3 x 7.9 cm
Figure 17: Gen. 8 Product Labeling Bridgelux COB arrays have laser markings on the back side of the substrate to help with product identification. In addition to the product identification markings, Bridgelux COB arrays also contain markings for internal Bridgelux manufacturing use only. The image below shows which markings are for customer use and which ones are for Bridgelux internal use only. The Bridgelux internal manufacturing markings are subject to change without notice, however these will not impact the form, function or performance of the COB array. Customer Use- 2D Barcode Scannable barcode provides product part number and other Bridgelux internal production information. Customer Use- Product part number Customer Use- Vf Bin Code included to enable greater luminaire design flexibility. Refer to AN92 for bin code definitions. 30E0400C 83 2F Internal Bin Code
Bridgelux has developed a comprehensive set of application notes and design resources to assist customers in successfully designing with the V Series product family of LED array products. For all available application notes visit www.bridgelux.com. Optical Source Models Optical source models and ray set files are available for all Bridgelux products. Please contact your Bridgelux Sales Representative for more information. MINOR PRODUCT CHANGE POLICY The rigorous qualification testing on products offered by Bridgelux provides performance assurance. Slight cosmetic changes that do not affect form, fit, or function may occur as Bridgelux continues product optimization. CAUTION: CHEMICAL EXPOSURE HAZARD Exposure to some chemicals commonly used in luminaire manufacturing and assembly can cause damage to the LED array. Please consult Bridgelux CAUTION: RISK OF BURN Do not touch the V Series LED array during operation. Allow the array to cool for a sufficient period of time before handling. The V Series LED array may reach elevated temperatures such that could burn skin when touched 3D CAD Models Three dimensional CAD models depicting the product outline of all Bridgelux V Series LED arrays are available in both IGS and STEP formats. Please contact your Bridgelux sales representative for assistance. LM80 LM80 testing has been completed and the LM80 report is now available. Please contact your Bridgelux sales rep- resentatives for LM-80 report. CAUTION CONTACT WITH LIGHT EMITTING SURFACE (LES) Avoid any contact with the LES. Do not touch the LES of the LED array or apply stress to the LES (yellow phosphor resin area). Contact may cause damage to the LED array. Optics and reflectors must not be mounted in contact with the LES (yellow phosphor resin area). Use the mechanical features of the LED array housing and/or edges to locate and secure optical devices as needed. STANDARD TEST CONDITIONS Unless otherwise stated, array testing is performed at the nominal drive current.
About Bridgelux: Bridging Light and Life™ © 2025 Bridgelux, Inc. All rights reserved. Product specifications are subject to change without notice. Bridgelux, the Bridgelux stylized logo design and Vero are registered trademarks, V Series and Decor Series are trademarks of Bridgelux, Inc. All other trademarks are the property of their respective owners. Bridgelux Gen 8 V6 Array Series Product Data Sheet DS410 Rev. E (04/2026)
46410 Fremont Boulevard
Fremont, CA 94538 USA Tel (925) 583-8400 www.bridgelux.com At Bridgelux, we help companies, industries and people experience the power and possibility of light. Since 2002, we’ve designed LED solutions that are high performing, energy efficient, cost effective and easy to integrate. Our focus is on light’s impact on human behavior, delivering products that create better environments, experiences and returns—both experiential and financial. And our patented technology drives new platforms for commercial and industrial luminaires. For more information about the company, please visit bridgelux.com twitter.com/Bridgelux facebook.com/Bridgelux youtube.com/user/Bridgelux linkedin.com/company/bridgelux-inc-_2 WeChat ID: BridgeluxInChina