DS323 BRIDGELUX | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 23

Technical content

Datasheet sections

BXRE-27S|30S|35S|40S|50S|57S|65S Bridgelux V8 Thrive™ Array Product Data Sheet DS323

Bridgelux Thrive™ combines unique chip, phosphor and packaging technology to closely match the spectra of natural light over the visible wavelength range. Thrive can be used in constant color point luminaires to bring full spectrum natural light indoors or in tunable white luminaires to incorporate circadian elements that may impact human well-being. The high fidelity spectral output of Thrive creates stunning environments with excellent color rendering and outstanding TM30 metrics. Thrive is available in both SMD components and LED arrays to enable a broad range of lighting applications including retail, hospitality, office, education, architectural, museums, healthcare and residential lighting.

Features

  • Engineered spectrum to closely match natural light
  • CRI >95, R1-R15 >90, high Rf and Rg values
  • High efficacy full spectrum solution
  • No violet chip augmentation
  • Hot color targeted
  • Form factor consistent with existing Bridgelux COB arrays
  • Broad product platform availability (SMDs and COBs) Benefits
  • Full consistent spectrum with fewer spectral spikes
  • Natural and vivid color rendering
  • Greater energy savings, lower utility costs
  • Economical, high efficiency solution
  • Uniform and consistent white light at application conditions
  • Ease of design and rapid go-to-market
  • Enables greater design flexibility and platform color consistency V8 Thrive

The part number designation for Bridgelux COB arrays is explained as follows: Bridgelux arrays are fully engineered devices that provide consistent thermal and optical performance on an engineered mechanical platform. The V Series arrays are the most compact chip-on-board devices across all of Bridgelux’s LED Array products. The arrays incorporate several features to simplify design integration and assembly. Please visit www.bridgelux.com for more information on the V Series family of products. BXRE – 30 S 0801 – D – 7 3 1 2 3 4 – 5 6 7 8 9 10 11 – 12 – 13 14 Product Family CCT Bin Options 2 = 2 SDCM 3 = 3 SDCM 4 = 4 SDCM Flux Indicator 0801 = 800 lm Minimum CRI S = Thrive Array Configuration Nominal CCT 27 = 2,700K 30 = 3,000K 35 = 3,500K 40 = 4,000K 50 = 5,000K 57 = 5,700K 65 = 6,500K Gen 7 Note: Part number and lot codes are scribed on back of array Polarity symbols Solder pads White ring around LES Case Temperature (Tc) Measurement Point Fully engineered substrate for consistent thermal, mechanical and optical properties Yellow phosphor Light Emitting Surface (LES)

The following product configurations are available: Table 1: Selection Guide, Pulsed Measurement Data (Tc= 25°C) Part Number1,6 Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Vf (V) Typical Pulsed Flux4,5,6,7 Tc = 25ºC (lm) Minimum Pulsed Flux6,7,8 Tc = 25ºC (lm) Typical Power (W) Typical Efficacy (lm/W) Typical Photosynthetic Photon Flux (PPF) Typical Photon Efficiency (µmol/J) BXRE-27S0801-D-7X 2700 98 350 17.3 630 554 6.1 104 11.51 1.91 BXRE-27S0801-E-7X 2700 98 175 34.7 630 554 6.1 104 11.51 1.91 BXRE-30S0801-D-7X 3000 98 350 17.3 677 596 6.1 111 11.77 1.96 BXRE-30S0801-E-7X 3000 98 175 34.7 677 596 6.1 111 11.77 1.96 BXRE-35S0801-D-7X 3500 98 350 17.3 728 641 6.1 120 11.90 1.98 BXRE-35S0801-E-7X 3500 98 175 34.7 728 641 6.1 120 11.90 1.98 BXRE-40S0801-D-7X 4000 98 350 17.3 740 652 6.1 122 12.33 2.05 BXRE-40S0801-E-7X 4000 98 175 34.7 740 652 6.1 122 12.33 2.05 BXRE-50S0801-D-7X 5000 98 350 17.3 777 683 6.1 128 12.35 2.05 BXRE-50S0801-E-7X 5000 98 175 34.7 777 683 6.1 128 12.35 2.05 BXRE-57S0801-D-7X 5700 98 350 17.3 789 694 6.1 130 13.20 2.19 BXRE-57S0801-E-7X 5700 98 175 34.7 789 694 6.1 130 13.20 2.19 BXRE-65S0801-D-7X 6500 98 350 17.3 771 678 6.1 127 12.60 2.09 BXRE-65S0801-E-7X 6500 98 175 34.7 771 678 6.1 127 12.60 2.09 Table 2: Selection Guide, Stabilized DC Test Performance (Tc= 85°C)4,5,6 Part Number1,6 Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Vf (V) Typical DC Flux4,5,6,7 Tc = 85ºC (lm) Minimum DC Flux6,7,8,9 Tc = 85ºC (lm) Typical Power (W) Typical Efficacy (lm/W) Typical Photosynthetic Photon Flux (PPF) Typical Photon Efficiency (µmol/J) BXRE-27S0801-D-7X 2700 98 350 16.7 567 499 5.8 97 10.79 1.83 BXRE-27S0801-E-7X 2700 98 175 33.4 567 499 5.8 97 10.79 1.83 BXRE-30S0801-D-7X 3000 98 350 16.7 609 536 5.8 104 10.97 1.86 BXRE-30S0801-E-7X 3000 98 175 33.4 609 536 5.8 104 10.97 1.86 BXRE-35S0801-D-7X 3500 98 350 16.7 656 577 5.8 112 11.62 1.97 BXRE-35S0801-E-7X 3500 98 175 33.4 656 577 5.8 112 11.62 1.97 BXRE-40S0801-D-7X 4000 98 350 16.7 666 586 5.8 114 11.79 2.00 BXRE-40S0801-E-7X 4000 98 175 33.4 666 586 5.8 114 11.79 2.00 BXRE-50S0801-D-7X 5000 98 350 16.7 699 615 5.8 120 11.85 2.01 BXRE-50S0801-E-7X 5000 98 175 33.4 699 615 5.8 120 11.85 2.01 BXRE-57S0801-D-7X 5700 98 350 16.7 710 625 5.8 121 12.30 2.09 BXRE-57S0801-E-7X 5700 98 175 33.4 710 625 5.8 121 12.30 2.09 BXRE-65S0801-D-7X 6500 98 350 16.7 694 610 5.8 119 12.11 2.05 BXRE-65S0801-E-7X 6500 98 175 33.4 694 610 5.8 119 12.11 2.05 Notes for Table 1 & 2: 1. Product CCT is hot targeted at Tj= 85°C. Nominal CCT as defined by ANSI C78.377-2011. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Bridgelux maintains a ±7% tolerance on flux measurements. 8. Minimum flux values at the nominal test current are guaranteed by 100% test. 9. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.

European Product Registry for Energy Labeling The European Product Registry for Energy Labeling (EPREL) is defined in the EU Regulation 2017/1369 to provide import- ant energy efficiency information to consumers. Together with Energy Labeling Regulation ELR (EU) 2019/2015 which was amended by regulation (EU) 2021/340 for energy labelling of light sources, manufacturers are required to declare an ener- gy class based on key technical specifications from each of their product and register it in an open data base managed by EPREL It is now a legal requirement for a vendor of light sources to upload information about their products into the EPREL database before placing these products on the market in the EU. Table 3 below provides a list of part numbers that are in compliance with ELR and are currently listed in the EPREL data- base. At Bridgelux, we are fully committed to supplying products that are compliant with pertinent laws, rules, and obligation imposed by relevant government bodies including the European Energy Labeling regulation. Customers can use these products with full confidence for any projects that fall under the ELR. Table 3: Part numbers registered in European Product Registry for Energy Labeling PART NUMBER1 CCT (K) CRI Current2 (mA) Vf (V) Useful flux3 (Φuse) at 85C (lm) Pow- er (W) Efficacy (lm/W) Energy efficiency class4 Regis- tration No URL to Product Information Sheet in EPREL Database Notes for Table 3: 1. All device listed here must be disposed as e-waste upon its end of life according to local country guideline in each country. 2. For information on performance values at alternative drive conditions. please refer to the Product Selection Guide, Absolute Maximum Rating Table and Performance Curves in this data sheet. 3. For a definition of useful luminous flux (ΦΦuse), please see the ELR regulations at https:/ /tinyurl.com/4b6zvt4m. 4. EPREL requires an arrow symbol containing the letter of the energy efficiency class to be displayed. on technical promotional material. Refer to this energy efficiency class column for specific energy efficiency class on each part number.

Performance at Commonly Used Drive Currents V Series Thrive LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. V Series Thrive LED Arrays may also be driven at other drive currents dependent on specific application design requirements. The performance at any drive current can be derived from the current vs. voltage characteristics shown in Figures 11 & 12 and the flux vs. current characteristics shown in Figures 13 & 14. The performance at commonly used drive currents is summarized in Table 4. Table 4: Product Performance at Commonly Used Drive Currents Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRE-27S0801-D-7x 98 175 16.6 2.9 325 293 112 250 16.9 4.2 458 412 108 350 17.3 6.1 630 567 104 500 17.8 8.9 875 787 98 700 18.4 12.9 1179 1061 91 BXRE-27S0801-E-7x 98 88 33.0 2.9 326 294 112 125 33.9 4.2 459 413 108 175 34.7 6.1 630 567 104 250 35.5 8.9 874 787 98 350 36.8 12.9 1179 1061 92 BXRE-30S0801-D-7x 98 175 16.6 2.9 349 314 120 250 16.9 4.2 492 443 116 350 17.3 6.1 677 609 112 500 17.8 8.9 940 846 105 700 18.4 12.9 1266 1140 98 BXRE-30S0801-E-7x 98 88 33.0 2.9 351 316 121 125 33.9 4.2 493 444 116 175 34.7 6.1 677 609 111 250 35.5 8.9 939 845 106 350 36.8 12.9 1267 1141 98 BXRE-35S0801-D-7x 98 175 16.6 2.9 376 338 129 250 16.9 4.2 529 476 125 350 17.3 6.1 728 656 120 500 17.8 8.9 1011 910 113 700 18.4 12.9 1362 1226 105 BXRE-35S0801-E-7x 98 88 33.0 2.9 377 339 130 125 33.9 4.2 531 477 125 175 34.7 6.1 728 656 120 250 35.5 8.9 1010 909 114 350 36.8 12.9 1363 1227 106 BXRE-40S0801-D-7x 98 175 16.6 2.9 382 344 131 250 16.9 4.2 538 484 127 350 17.3 6.1 740 666 122 500 17.8 8.9 1027 925 115 700 18.4 12.9 1384 1246 107 BXRE-40S0801-E-7x 98 88 33.0 2.9 383 345 132 125 33.9 4.2 539 485 127 175 34.7 6.1 740 666 122 250 35.5 8.9 1027 924 116 350 36.8 12.9 1385 1247 108 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRE-50S0801-D-7x 98 175 16.6 2.9 401 361 138 250 16.9 4.2 565 508 134 350 17.3 6.1 777 699 128 500 17.8 8.9 1079 971 121 700 18.4 12.9 1454 1308 113 BXRE-50S0801-E-7x 98 88 33.0 2.9 402 362 139 125 33.9 4.2 566 510 134 175 34.7 6.1 777 699 128 250 35.5 8.9 1078 970 121 350 36.8 12.9 1455 1309 113 BXRE-57S0801-D-7x 98 175 16.6 2.9 407 366 140 250 16.9 4.2 574 516 136 350 17.3 6.1 789 710 130 500 17.8 8.9 1095 986 123 700 18.4 12.9 1476 1328 114 BXRE-57S0801-E-7x 98 88 33.0 2.9 409 368 141 125 33.9 4.2 575 517 136 175 34.7 6.1 789 710 130 250 35.5 8.9 1095 985 123 350 36.8 12.9 1477 1329 115 BXRE-65S0801-D-7x 98 175 16.6 2.9 398 358 137 250 16.9 4.2 560 504 132 350 17.3 6.1 771 694 127 500 17.8 8.9 1070 963 120 700 18.4 12.9 1442 1298 112 BXRE-65S0801-E-7x 98 88 33.0 2.9 399 359 137 125 33.9 4.2 562 506 133 175 34.7 6.1 771 694 127 250 35.5 8.9 1070 963 121 350 36.8 12.9 1443 1299 112 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Electrical Characteristics

Table 7: Electrical Characteristics Notes for Table 7: 1. Parts are tested in pulsed conditions, Tc = 25°C. Pulse width is 10ms. 2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance. 3. Bridgelux maintains a tester tolerance of ± 0.10V on forward voltage measurements. 4. Typical coefficient of forward voltage tolerance is ± 0.1mV for nominal current. 5. Thermal resistance values are based from test data of a 3000K 80 CRI product. 6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal interface material used during testing is not included in the thermal resistance value. 7. Vf min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design and selection over the operating range of the product. 8. This product has been designed and manufactured per IEC 62031:2018. This product has passed dielectric withstand voltage testing at 1160 V. The working voltage designated for the insulation is 80V d.c. The maximum allowable voltage across the array must be determined in the end product application. Part Number Drive Current (mA) Forward Voltage Pulsed, Tc = 25ºC (V) 1, 2, 3, 8 Typical Coefficient of Forward Voltage4 ∆Vf/∆Tc (mV/ºC) Typical Thermal Resistance Junction to Case5,6 Rj-c (ºC/W) Driver Selection Voltages7 (V) Minimum Typical Maximum Vf Min. Hot Tc = 105ºC (V) Vf Max. Cold Tc = -40ºC (V) BXRE-xxx080x-D-7x BXRE-xxx080x-E-7x

Table 8: Maximum Ratings Parameter Maximum Rating LED Junction Temperature (Tj) 150°C Storage Temperature -40°C to +105°C Operating Case Temperature1 (Tc) 105°C Soldering Temperature2 300°C or lower for a maximum of 6 seconds BXRE-xxx080x-D-7x BXRE-xxx080x-E-7x Maximum Drive Current3 700mA 350mA Maximum Peak Pulsed Drive Current4 1000mA 500mA Maximum Reverse Voltage5 -30V -60V Notes for Table 8: 1. For IEC 62717 requirement, please consult your Bridgelux sales representative. 2. Refer to Bridgelux Application Note AN101: Handling and Assembly of Bridgelux V Series LED Arrays. 3. Arrays may be driven at higher currents however lumen maintenance may be reduced. 4. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed current specified. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures. 5. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating provided for reference only.

Table 9: Eye Safety Risk Group (RG) Classifications Part Number Drive Current 4 (mA) CCT1,4 2700K/3000K 4000K 5000K2 6500K3 BXRE-xxx080x-D-7x

350 RG1 RG1 RG1 RG1

500 RG1 RG1 RG2 RG2

700 RG1 RG1 RG2 RG2

175 RG1 RG1 RG1 RG2

250 RG1 RG1 RG2 RG2

350 RG1 RG1 RG2 RG2

Notes for Table 9: 1. Eye safety classification for the use of Bridgelux V Series LED arrays is in accordance with specification IEC/TR 62778: Application of IEC 62471 for the assess- ment of blue light hazard to light sources and luminaires. 2. For products classified as RG2 at 5000K Ethr= 1315.8 lx. 3. For products classified as RG2 at 6500K, Ethr= 1124.5 lx. 4. Please contact your Bridgelux sales representative for Ethr values at specific drive currents and CCTs not listed. Eye Safety

Table 10: 2-, 3- and 4-step MacAdam Ellipse Color Bin Definitions CCT Center Point Degree 2-step 3-step 4-step x y λ(°) a b a b a b Notes for Table 10: 1. Color binning at Tc=85°C 2. Bridgelux maintains a tolerance of ± 0.007 on x and y color coordinates in the CIE 1931 color space. Figure 10: C.I.E. 1931 Chromaticity Diagram (Color targeted at Tc=85°C) 0.34 0.36 0.38 0.4 0.42 0.44 Y X

3 SDCM

2 SDCM

0.3 0.31 0.32 0.33 0.34 0.35 0.36 0.37 0.38 0.39 Y X

4 SDCM

Figure 20: V8 LED Array Notes for Figure 20: 1. Drawings are not to scale. 2. Drawing dimensions are in millimeters. 3. Solder pads are labeled “+” and “-“ to denote positive and negative polarity, respectively. 4. Unless otherwise specified, tolerances are ±0.1mm. 5. Refer to Application Notes AN101 for product handling, mounting and heat sink recommendations. 6. The optical center of the LED Array is nominally defined by the mechanical center of the array to a tolerance of ± 0.2mm. 7. Bridgelux maintains a flatness of 0.10mm across the mounting surface of the array.

Figure 21: V8 Packaging Notes for Figure 21: 1. Each tube holds 40 V8 COB arrays. 2. One tube is sealed in an anti-static bag. Four bags are placed in a shipping box. Depending on quantities ordered, a bigger shipping box, containing four boxes may be used to ship products. 3. Each bag and box is to be labeled as shown above. the shipping box are 58.7 x 13.3 x 7.9 cm

Figure 22: Gen. 7 Product Labeling Bridgelux COB arrays have laser markings on the back side of the substrate to help with product identification. In addition to the product identification markings, Bridgelux COB arrays also contain markings for internal Bridgelux manufacturing use only. The image below shows which markings are for customer use and which ones are for Bridgelux internal use only. The Bridgelux internal manufacturing markings are subject to change without notice, however these will not impact the form, function or performance of the COB array. Customer Use- 2D Barcode Scannable barcode provides product part number and other Bridgelux internal production information. Customer Use- Product part number 30S0801D 73 2F Customer Use- Vf Bin Code included to enable greater luminaire design flexibility. Refer to AN92 for bin code definitions.

Bridgelux has developed a comprehensive set of application notes and design resources to assist customers in successfully designing with the V Series product family of LED array products. For all available application notes visit www.bridgelux.com. Optical Source Models Optical source models and ray set files are available for all Bridgelux products. For a list of available formats, visit www.bridgelux.com. MINOR PRODUCT CHANGE POLICY The rigorous qualification testing on products offered by Bridgelux provides performance assurance. Slight cos- metic changes that do not affect form, fit, or function may occur as Bridgelux continues product optimization. CAUTION: CHEMICAL EXPOSURE HAZARD Exposure to some chemicals commonly used in luminaire manufacturing and assembly can cause damage to the LED array. Please consult Bridgelux CAUTION: RISK OF BURN Do not touch the V Series LED array during operation. Allow the array to cool for a sufficient period of time before handling. The V Series LED array may reach elevated temperatures such that could burn skin when touched. 3D CAD Models Three dimensional CAD models depicting the product outline of all Bridgelux V Series LED arrays are available in both IGS and STEP formats. Please contact your Bridgelux sales representative for assistance. LM80 LM80 testing has been completed and the LM80 report is now available. Please contact your Bridgelux sales representative for LM-80 report. STANDARD TEST CONDITIONS Unless otherwise stated, array testing is performed at the nominal drive current. CAUTION CONTACT WITH LIGHT EMITTING SURFACE (LES) Avoid any contact with the LES. Do not touch the LES of the LED array or apply stress to the LES (yellow phosphor resin area). Contact may cause damage to the LED array. Optics and reflectors must not be mounted in contact with the LES (yellow phosphor resin area).

About Bridgelux: Bridging Light and Life™ © 2021 Bridgelux, Inc. Product specifications are subject to change without notice. Bridgelux and the Bridgelux stylized logo design are registered trademarks of Bridgelux, Inc. All other trademarks are the property of their respective owners. Bridgelux V8 Thrive Array Product Data Sheet DS323 Rev. B (08/2021)

46410 Fremont Boulevard

Fremont, CA 94538 USA Tel (925) 583-8400 www.bridgelux.com At Bridgelux, we help companies, industries and people experience the power and possibility of light. Since 2002, we’ve designed LED solutions that are high performing, energy efficient, cost effective and easy to integrate. Our focus is on light’s impact on human behavior, delivering products that create better environments, experiences and returns—both experiential and financial. And our patented technology drives new platforms for commercial and industrial luminaires. For more information about the company, please visit bridgelux.com twitter.com/Bridgelux facebook.com/Bridgelux linkedin.com/company/bridgelux-inc-_2 youtube.com/user/Bridgelux WeChat ID: BridgeluxInChina