DS3121 BRIDGELUX | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 14

Technical content

EB Series™ 1” Breakable 1-Row LED Product Data Sheet DS3121 Length: 1206mm CRI: 80, 90 CCTs: 2700K, 3000K, 3500K, 4000K, 5000K, 5700K, 6500K

Bridgelux EB Series 1” Breakable modules are fully engineered devices that provide consistent thermal and optical performance on an engineered mechanical platform. The linear products incorporate several features to simplify design integration and assembly. Please visit www.bridgelux.com for more information on the EB Series family of products. Product Nomenclature The part number designation for Bridgelux EB Series 1” Breakable is explained as follows: Zhaga compatible mounting holes Designed to comply with global safety standards for creepage and clearance distances Label containing part number and lot codes is attached on the front of the module where shown Re-usable connector Multiple case temperature measurement points Nominal CCT 27 = 2700K 30 = 3000K 35 = 3500K 40 = 4000K 50 = 5000K 57 = 5700K 65 = 6500K 1 2 3 4 5 6 7 8 9 1011 12 13141516 17181920 21 22 L1206 4000 D30448 Module Version D = Product Version (1-Row LED, breakable) (with backside tape) Flux Indicator 4000 = 4000 lm 5000 = 5000 lm Module Configuration 04 = 4 in series 48 = 48 in parallel Nominal Dimensions L= Linear 1206 = 1206 mm 40 G Minimum CRI E = 80 G = 90 – – – –BXEB Product Family

Table 1: Selection Guide, Measurement Data (Tc = 25° C) Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. 2. CRI Values are minimums. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal drive current where Tc (case temperature) = 25°C. Values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ± 7% tolerance on typical flux measurements Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current (mA) Forward Voltage (V) Typical Power (W) Typical Pulsed Flux3, 4 (lm) Typical Efficacy (lm/W) BXEB-L1206-27E5000-0448-D3 2700 80 716 32 23.1 4860 210 BXEB-L1206-30E5000-0448-D3 3000 4906 212 BXEB-L1206-35E5000-0448-D3 3500 4906 212 BXEB-L1206-40E5000-0448-D3 4000 5040 218 BXEB-L1206-50E5000-0448-D3 5000 5040 218 BXEB-L1206-57E5000-0448-D3 5700 4999 216 BXEB-L1206-65E5000-0448-D3 6500 4999 216 BXEB-L1206-27G4000-0448-D3 2700 90 716 33 23.6 3820 162 BXEB-L1206-30G4000-0448-D3 3000 4002 169 BXEB-L1206-35G4000-0448-D3 3500 4002 169 BXEB-L1206-40G4000-0448-D3 4000 4184 177 BXEB-L1206-50G4000-0448-D3 5000 4184 177 BXEB-L1206-57G4000-0448-D3 5700 4093 173 BXEB-L1206-65G4000-0448-D3 6500 4093 173

Performance at Commonly Used Drive Currents Table 2: Performance at Commonly Used Drive Currents (Tc = 25° C) Notes for Table 2: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. Part Number CRI Drive Current1 (mA) Typical Vf (V) Typical Power (W) Typical Pulsed Flux2 (lm) Typical Efficacy (lm/W) BXEB-L1206-27E5000-0448-D3 80 146 31.5 4.6 990 215 476 31.9 15.3 3270 213 716 32.1 23.1 4860 210 956 32.4 31.1 6439 207 1500 32.9 49.4 9898 200 BXEB-L1206-30E5000-0448-D3 BXEB-L1206-35E5000-0448-D3 80 146 31.5 4.6 999 217 476 31.9 15.3 3301 215 716 32.1 23.1 4906 212 956 32.4 31.1 6500 209 1500 32.9 49.4 9996 202 BXEB-L1206-40E5000-0448-D3 BXEB-L1206-50E5000-0448-D3 80 146 31.5 4.6 1027 223 476 31.9 15.3 3391 221 716 32.1 23.1 5040 218 956 32.4 31.1 6678 215 1500 32.9 49.4 10290 208 BXEB-L1206-57E5000-0448-D3 BXEB-L1206-65E5000-0448-D3 80 146 31.5 4.6 1017 221 476 31.9 15.3 3363 219 716 32.1 23.1 4999 216 956 32.4 31.1 6623 213 1500 32.9 49.4 10192 206 BXEB-L1206-27G4000-0448-D3 90 146 31.5 4.6 856 186 476 32.4 15.4 2574 167 716 33 23.6 3820 162 956 33.6 32.1 5039 157 1500 34.7 52.1 7702 148 BXEB-L1206-30G4000-0448-D3 BXEB-L1206-35G4000-0448-D3 90 146 31.5 4.6 898 195 476 32.4 15.4 2697 175 716 33 23.6 4002 169 956 33.6 32.1 5279 164 1500 34.7 52.1 8064 155 BXEB-L1206-40G4000-0448-D3 BXEB-L1206-50G4000-0448-D3 90 146 31.5 4.6 921 200 476 32.4 15.4 2820 183 716 33 23.6 4184 177 956 33.6 32.1 5519 172 1500 34.7 52.1 8477 163 BXEB-L1206-57G4000-0448-D3 BXEB-L1206-65G4000-0448-D3 90 146 31.5 4.6 921 200 476 32.4 15.4 2758 179 716 33 23.6 4093 173 956 33.6 32.1 5399 168 1500 34.7 52.1 8271 159 EB series 1” Breakable modules are tested to the specifications shown using the nominal drive currents in Table 1. EB series 1” Breakable modules may also be driven at other drive currents dependent on specific application design re- quirements. The performance at any drive current can be derived from the current vs. voltage characteristics shown in Figure 1, and the flux vs. current characteristics shown in Figure 2. The performance at commonly used drive currents is summarized in Table 2.

Table 3: Maximum Ratings Parameter Maximum Rating Storage Temperature -40°C to +85°C Operating Case Temperature2 (Tc) 85°C Soldering Temperature 350°C or lower for a maximum of 5 seconds Maximum Reverse Voltage Modules are not designed to be driven in reverse bias BXEB-L1206-xxG4000-0448-D3 BXEB-L1206-xxE5000-0448-D3 Maximum Drive Current 2000 mA 2000 mA Notes for Table 3: 1. For IEC 62717 requirement, please consult your Bridgelux sales representative. 2. Lumen maintenance (L70) and lifetime predictions are valid for drive current and case temperature conditions used for LM-80 testing as included in the applicable LM-80 test report for the SMDs used in the modules. Contact your Bridgelux sales representatives for LM-80 report. 3. Max drive current values are provided as a reference only with LED module mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.

Figure 4: Typical Spatial Radiation Pattern Notes for Figure 4: 1. Typical viewing angle is 120⁰. 2. The viewing angle is defined as the off axis angle from the centerline where Iv is ½ of the peak value. 20% 40% 60% 80% 100% 120% -100 -80 -60 -40 -20 0 20 40 60 80 100 Relative Intensity Angle (°)

Figure 7: Drawing Overview for 1206mm Notes for Figure 7:: 1. Solder pads are labeled “+” to denote positive polarity, and “-” to denote negative polarity. 2. Drawing dimensions are in millimeters. 3. Unless otherwise specified, tolerances are ±0.1 mm. 4. Markings on both ends of the board, including the Bridgelux part number, CRI, and CCT as shown in the figure below:

  • CCT options: 2700 K / 3000 K / 3500 K / 4000 K
  • CRI options: 80+ / 90+ Parameter BXEB-L1206-xxG4000-0448-D3 BXEB-L1206-xxE5000-0448-D3 Linear length 1205.79 mm Linear width 20.0 mm Overall thickness 6.1 mm PCB thickness 1.6 mm Input wire cross-section 18-24 AWG Wire strip length 7-9 mm Table 4: Module Dimensions & Connector Wiring
  • Please use antistatic gloves or other ESD protection methods when handling this breakable board to prevent ESD damage or contamination of LEDs. * Customers should use proper tools and avoid using their hands when separating this breakable board. It is not allowed to bend PCB and touch LED. * Cutting pressure should be applied as close as possible to the separation line. Keep your fingers away from the LEDs as much as possible to avoid damage to the LEDs. * It is very important to follow above guidelines when separating the breakable board to ensure that the product warranty is not voided.

Figure 8: 3 SDCM Color Bins in CIE 1931 xy Color Space Table 5: Bin Coordinates and Associated Typical CCT Notes for Table 5: 1. Color binning at solder point temperature Tsp of SMDs at 60°C. 2. Bridgelux maintains a tolerance of ± 0.007 on x and y color coordinates in the CIE 1931 color space 0.30 0.32 0.34 0.36 0.38 0.40 0.42 0.44 CIE y CIE x CCT Color Consistency CIE Center Point (x, y) Corresponding CCT Range 2700K 3 SDCM (0.458, 0.410) 2651K - 2794K 3000K 3 SDCM (0.434, 0.403) 2968K - 3136K 3500K 3 SDCM (0.407, 0.392) 3369K - 3586K 4000K 3 SDCM (0.382, 0.380) 3851K - 4130K 5000K 3 SDCM (0.3445, 0.355) 4835K - 5215K 5700K 3 SDCM (0.329, 0.342) 5490K - 5820K 6500K 3 SDCM (0.312, 0.328) 6250K - 6745K Note for Figure 8: 1. Quadrangular ANSI bins shown for reference only 2. Bridgelux maintains a tolerance of ± 0.007 on x and y color coordinates in the CIE 1931 color space

Bridgelux has developed a comprehensive set of application notes and design resources to assist customers in successfully designing with the EB Series product family. For a list of resources under development, visit www.bridgelux.com. Optical Source Models Optical source models and ray set files are available for all Bridgelux products. For a list of available formats, visit www.bridgelux.com. MINOR PRODUCT CHANGE POLICY The rigorous qualification testing on products offered by Bridgelux provides performance assurance. Slight cosmetic changes that do not affect form, fit, or function may occur as Bridgelux continues product optimization. CAUTION: CHEMICAL EXPOSURE HAZARD Exposure to some chemicals commonly used in luminaire manufacturing and assembly can cause damage to the LED linear. Please consult Bridgelux Application Note for additional information. CAUTION: EYE SAFETY The Bridgelux EB series emits visible light, that, under certain circumstances, could be harmful to the eye. Proper safeguards must be used. CAUTION: RISK OF BURN Do not touch the EB Series linears during operation. Allow the linear to cool for a sufficient period of time be- fore handling. The EB Series linears may reach elevated temperatures such that could burn skin when touched. 3D CAD Models Three dimensional CAD models depicting the product outline of all Bridgelux EB Series LED linears are available in both IGES and STEP formats. Please contact your Bridgelux sales representative for assistance. CAUTION CONTACT WITH LIGHT EMITTING SURFACE (LES) Avoid any contact with the LES. Do not touch the LES of the linear or apply stress to the LES (yellow phosphor resin area). Contact may cause damage to the linear. Optics and reflectors must not be mounted in con- tact with the LES (yellow phosphor resin area). Optical devices may be mounted on the top surface of the EB Series linear. Use the mechanical features of the linear housing, edges and/or mounting holes to locate and secure optical devices as needed. STANDARD TEST CONDITIONS Unless otherwise stated, linear testing is performed at the nominal drive current.

About Bridgelux: Bridging Light and Life™ © 2026 Bridgelux, Inc. All rights reserved. Product specifications are subject to change without notice. Bridgelux and the Bridgelux stylized logo design are registered trade- marks of Bridgelux, Inc. EB Series and Bridging Light and Life are trademarks of Bridgelux, Inc. All other trademarks are the property of their respective owners. Bridgelux EB Series 1” Breakable 1-R欧欧ow LED Data Sheet DS3121 Rev. A (03/2026)

46410 Fremont Blvd

Fremont, CA 94538 USA Tel (925) 583-8400 Fax (925) 583-8401 www.bridgelux.com At Bridgelux, we help companies, industries and people experience the power and possibility of light. Since 2002, we’ve designed LED solutions that are high performing, energy efficient, cost effective and easy to integrate. Our focus is on light’s impact on human behavior, delivering products that create better environments, experiences and returns—both experiential and financial. And our patented technology drives new platforms for commercial and industrial luminaires. For more information about the company, please visit bridgelux.com twitter.com/Bridgelux facebook.com/Bridgelux youtube.com/user/Bridgelux linkedin.com/company/bridgelux-inc-_2 WeChat ID: BridgeluxInChina