DS3000TE ADVANCEDENERGY | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 11

Technical content

©2020 Advanced Energy Industries, Inc. ARTESYN DS3000TE

3000 Watt Front-End AC-DC Power Supply

Total Output Power:

3000 W continuous

208 Vac to 264 Vac, 3000 W

DATA SHEETAdvanced Energy's Artesyn DS3000TE series bulk front end power AC-DC supply is designed to fully utilize the current capacity of standard C19/C20 AC inlet distribution connectors. It accepts 180–264 Vac input and provides a main 12 V output plus a 12 V standby output. Rated at 3,000 watts when operating from a 208-264 Vac input, the DS3000TE is an 80 Plus Titanium power supply with a very high conversion efficiency of more than 96% at 50% load. Housed in a compact enclosure measuring just 4.15 x 2.78 x 11 inches, the power supply has a power density of 24 watts per cubic inch; six units can fit on a standard 19 inch rack shelf, to provide a total of 18 kilowatts. SPECIAL FEATURES  3000 W output power  High power and narrow form factor  Six (6) units can fit in a 19” inch rack for a total of 16.2 kW  High density design: 24 W/in  Active Power Factor Correction  EN61000-3-2 harmonic compliance  Inrush current control  80plus titanium efficiency  N+1 or N+N redundant  Hot-pluggable  Active current sharing  Full digital control  PMBus compliant  Compatible with Artesyn’s universal PMBus GUI  Two-year warranty COMPLIANCE  Conducted/Radiated EMI EN55022 Class A Limits  RoHS SAFETY  UL/cUL  DEMKO+ CB Report EN60950  BSMI  CE Mark  China CQC

2 advancedenergy.com DS3000TE ELECTRICAL SPECIFICATIONS Input Input voltage range Forward air: 208 to 264 Vac , 3000 W Reverse air: 208 to 264 Vac , 2960 W Frequency 47 Hz to 63 Hz Efficiency 96.0% peak Max input current <16.0 Arms @ 208 Vac Inrush current 55 Apk Conducted EMI Class A Radiated EMI Class A Power factor >0.98 at full load ITHD 10% at 50% load Leakage current 0.75 mA Hold-up time 11 ms

Ordering Information

DS3000TE-3 Standard Airflow DS3000TE-3-402 Reverse Airflow 1 2700 W output rating at 180-207 Vac 2 2664 W output rating at 180-207 Vac

advancedenergy.com 3 DS3000TE ELECTRICAL SPECIFICATIONS (CONTINUED) Output Main DC Output MIN NOM MAX Nominal setting -0.20% 12.1 0.20% Total output regulation range 11.5 V 12.7 V Dynamic load regulation range -5% +5% Output ripple 160 mVp-p Output current 1.0 250 A Current sharing Within 16 A of each other Capacitive loading 1,000 µF 17,000 µF Start-up from AC to output 2500 ms Output rise time 5 ms 60 ms Standby DC Output Nominal setting -2% 12.0 V 2% Total output regulation range 11.5 V 12.7 V Dynamic load regulation range -5% +5% Output ripple 160 mVp-p Output current 0 A 4.5 A Current sharing N/A Capacitive loading 27 µF 620 µF Start-up from AC to output 2000 ms Output rise time 2 ms 60 ms Protections Main Output Overcurrent protection 260A 280A Overvoltage protection 14.0 V 15.0 V Undervoltage protection 9.6 V 10.5 V Overtemperature protection Yes Fan fault protection Yes Standby Output Overcurrent protection 110% 150% Overvoltage protection 13.5 V 15.0 V Undervoltage protection 9.2 V 10.1 V

1 Latch mode

2 Autorecovery if the overcurrent is less than 104% and last only for <500 ms.

3 Standby protection is latch off

4 advancedenergy.com DS3000TE CONTROL AND STATUS SIGNALS Input Signals PSON Active LOW signal which enables/disables the main output. Pulling this signal LOW will turn-on the main output. Recommended pull-up resistor to 12 VSB is 8.2 k with a 3.0 k pull-down to ground. A 100 pF decoupling capacitor is also recommended. MIN MAX VIL Input logic level LOW 0.0 V 0.8 V VIH Input logic level HIGH 2.0 V 3.6 V TRISE/FALL Expect rise and fall times 1 µs PSKIL First break/last mate active LOW signal which enables/disables the main output. This signal will have to be pulled to ground at the system side with a 50 ohm resistor. A 100 pF decoupling capacitor is also recommended. MIN MAX VIL Input logic level LOW 0.0 V 0.8 V VIH Input logic level HIGH 2.0 V 3.6 V A0, A1, A2 Addressing pins of the power supply for I C communications. It is recommended for the system to have pull-ups and decoupling on the address lines for better noise immunity. Refer to the addressing tables below. MIN MAX 1k ohm Internal pull-ups to 3.3 V VIL Input logic level LOW 0.8 V VIH Input logic level HIGH 2.0 V 3.6 V ISOURCE Current that may be sourced by this pin 4 mA Output Signals ACOK Signal used to indicate the presence of AC input to the power supply. A logic level HIGH will indicate that the AC input to the power supply is within the operating range while a logic level LOW will indicate that AC has been lost. This is an open collector/drain output. This pin is pulled high by a 1.0 k ohm resistor connected to 3.3 V inside the power supply. It is recommended that this pin be connected to a 100 pF decoupling capacitor and pulled down by a 100 k ohm resistor. MIN MAX VOL Output logic level LOW 0.4 V VOH Output logic level HIGH 2.4 V 3.6 V ISOURCE Current that may be sourced by this pin 4 mA ISINK Current that may be sunk by this pin at low state 0.5 mA

advancedenergy.com 5 DS3000TE CONTROL AND STATUS SIGNALS (CONTINUED) PWR_GOOD / PWOK Signal used to indicate that main output voltage is within regulation range. The PWR_GOOD signal will be driven HIGH when the output voltage is valid and will be driven LOW when the output falls below the under-voltage threshold. This signal also gives an advance warning when there is an impending power loss due to loss of AC input or system shutdown request. More details in the Timing Section. This is an open collector/drain output. This pin is pulled high by a 1.0 k ohm resistor connected to 3.3 V inside the power supply. It is recommended that this pin be connected to a 100 pF decoupling capacitor and pulled down by a 10 k ohm resistor. MIN MAX V OL Output logic level LOW 0.4 V VOH Output logic level HIGH 2.4 V 3.6 V ISOURCE Current that may be sourced by this pin 4 mA PS_PRESENT Signal used to indicate to the system that a power supply is inserted in the power bay. Recommended pull-up resistor to 12 VSB is 8.2 k with a 3.0 k pull-down to ground. A 100 pF decoupling capacitor is also recommended. PS_INTERRUPT Active low signal used by the power supply to indicate to the system that a change in power supply status has occurred. This event can be triggered by faults such as OVP , OCP , OTP , and fan fault. This signal can be cleared by a CLEAR_FAULT command. Recommended pull-up resistor to 12 VSB is 8.2 k with a 3.0 k pull-down to ground. A 100 pF decoupling capacitor is also recommended. MIN MAX V OL Output logic level LOW 0.4 V VOH Output logic level HIGH 2.4 V 3.6 V ISINK Current that may be sunk by this pin at low state 4 mA BUS Signals ISHARE Bus signal used by the power supply for active current sharing. All power supplies configured in the system for n+n sharing will refer to this bus voltage inorder to load share. Voltage Range The range of this signal for active sharing will be up to 8.0 V, which corresponds to the maximum output current. MIN MAX ISHARE Voltage Voltage at 100% load, stand alone unit 7.75 8.25 Voltage at 50% load, stand-alone unit 3.85 4.15 Voltage at 0% load, stand-alone unit 0 0.3 ISOURCE Current that may be sourced by this pin 10.0 mA SCL, SDA Clock, data and addressing signals defined as per I C requirements. The maximum system side resistor pull-up and decoupling capacitance MIN MAX VL Logic level LOW 0.8 V VH Logic level HIGH 2.0 V 3.6 V Note: All signal noise levels are below 400 mVpk-pk from 0 - 100 MHz.

6 advancedenergy.com DS3000TE CONTROL AND STATUS SIGNALS (CONTINUED) I C Addressing Table FRU ADDRESSING A2 A1 A0 Address HIGH LOW LOW 0 x A9 HIGH LOW HIGH 0 x AB HIGH HIGH LOW 0 x AD HIGH HIGH HIGH 0 x AF* PMBus Addressing Address 0 x B9 0 x BB 0 x BD 0 x BF FRU ADDRESSING A2 A1 A0 Address LOW LOW LOW 0 x A1 LOW LOW HIGH 0 x A3 LOW HIGH LOW 0 x A5 LOW HIGH HIGH 0 x A7* PMBus Addressing Address 0 x B1 0 x B3 0 x B5 0 x B7 * Default address when AO and A1 are open * Subtract 1 for Write Address

advancedenergy.com 7 DS3000TE ELECTRICAL SPECIFICATIONS LED Indicators AC GOOD LED DC GOOD LED FAULT LED Color GREEN GREEN AMBER No AC input to PSU Off Off Off AC present, STBY ON, main output OFF On Off Off Main output ON On On Off Power supply failure (OVP , OTP , FAN FAULT) On Off Blinking Firmware Reporting And Monitoring Accuracy Range Output loading 5 to 20% 20 to 50% 50 to 100% Input voltage ±3% Input current ±0.55 A fixed error ±4% Input power ±20 W at < 100 W input ±5% Output voltage ±2% Output current ±3 A ±4% ±2% Temperature ±5 °C on the operating range EIN ±15% (at 10% minimum load) ±5% Fan speed ±250 RPM PMBus YES Remote ON/OFF YES Timing Specifications Description Min Max Unit Tsb_On Delay from AC being applied to standby output being within regulation 2000 ms Tsb_vout Delay from standby output to main output voltage being within regulation 300 ms TACOK_ON Delay from application of input to ACOK assertion 2020 ms Tac_on_delay Delay from AC being applied to main output being within regulation 2500 ms Tpwok_on Delay from output voltages within regulation limits to PWOK asserted 100 1000 ms Tacok_delay Delay from loss of AC to assertion of ACOK 10 ms Tpwok_hold-up Delay from loss of AC to deassertion of PWOK 10 ms Tvout_hold-up Delay from loss of AC to main output falling out of regulation 11 ms Tsb_Hold-up Delay from loss of AC to standby output being within regulation 150 2000 ms TPWR_GOOD_Off Delay from deassertion of PWOK to output falling out of regulation 1 990 ms TPSON_On_Delay Delay from PSON assertion to output being within regulation 350 ms

8 advancedenergy.com DS3000TE ENVIRONMENTAL SPECIFICATIONS TIMING DIAGRAM Operating temperature 0 to 40 °C Operating altitude up to 13,200 feet Operating relative humidity 5% to 95% non-condensing Non-operating temperature -40 to +90 °C Non-operating relative humidity 5% to 95% non-condensing Non-operating altitude up to 30,000 feet Vibration and shock Standard operating/non-operating random vibration/shock ROHS compliance Yes MTBF 400,000 hours Operating life Minimum of 5 years PSON Vout_main PWOK ACOK Vout_stby AC Input Tsb_On TAC_On_Delay Tsb_Vout TPSON_On_Delay Tsb_Hold-up TPWOK_Hold-up TVout_Hold-up TPWOK_Off TACOK_Delay TPWOK_On TACOK_ON

advancedenergy.com 9 DS3000TE MECHANICAL OUTLINE AIRFLOW DIRECTION FORWARD REVERSE INSUL,NON THERM,POLYCARBONATE, 0.25mm,15mm,11mm,V-0 SEE P/N: 621-003276-0000 INSUL,NON THERM,POLYCARBONATE, 0.25mm,15mm,11mm,V-0 SEE P/N: 621-003276-0000 MODEL LABEL SEE P/N: 531-003173-000X LABEL HOT SURFACE SEE P/N: 530-000237-000X LBL,PPRTD,700-011079-0000 SEE P/N 534-000656-000X 9.1 0.25 61.5 0.25 5.93 0.48 85.95 0.5 260.5 0.5 256 0.5 26 0.65 9 0.4 70.6 0.6 105.5 0.5 3D VIEW

10 advancedenergy.com DS3000TE Output Connector Part Number 75555-104 Mating Connector Part Number 75541-104REVB1 or any other Molex recommended part Pin Signal Name Amps per pin PB1 RETURN 150 PB2 RETURN 150 PB3 12 V 150 PB4 12 V 150 A1 PWR GOOD N/A A2 PSKILL N/A A3 PRESENT N/A B1 RETURN N/A B2 ISHARE N/A B3 RETURN N/A C1 PS_INTERRUPT N/A C2 RETURN N/A C3 ACOK N/A D1 RETURN N/A D2 PSON N/A D3 RESERVED N/A E1 SDA N/A E2 SCL N/A E3 A0 N/A F1 RESERVED N/A F2 A1 N/A F3 A2 N/A G1 RESERVED N/A G2 RESERVED N/A G3 RESERVED N/A H1 12 VSB 2 H2 12 VSB 2 H3 12 VSB 2 CONNECTOR DEFINITIONS

ENG-DS3000TE-235-01 12.23 For international contact information, visit advancedenergy .com. powersales@aei.com (Sales Support) productsupport.ep@aei.com (Technical Support) +1 888 412 7832 ABOUT ADVANCED ENERGY Advanced Energy (AE) has devoted more than three decades to perfecting power for its global customers. AE designs and manufactures highly engineered, precision power conversion, measurement and control solutions for mission-critical applications and processes. Our products enable customer innovation in complex applications for a wide range of industries including semiconductor equipment, industrial, manufacturing, telecommunications, data center computing, and medical. With deep applications know-how and responsive service and support across the globe, we build collaborative partnerships to meet rapid technological developments, propel growth for our customers, and innovate the future of power. Specifications are subject to change without notice. Not responsible for errors or omissions. ©2020 Advanced Energy Industries, Inc. All rights reserved. Advanced Energy®, AE® and Artesyn™ are U.S. trademarks of Advanced Energy Industries, Inc.