DS3 PENTAIR | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 12
Technical content
OWNER’S MANUAL Self-Priming Centrifugal Pump 3621 0714 ASB “DS3” Series Installation/Operation/Parts For further operating, installation, or maintenance assistance: Call 888-782-7483 © 2014 Pentair Ltd. All Rights Reserved. S536 (07/07/14) 293 WRIGHT STREET, DELAVAN, WI 53115 WWW.STA-RITE.COM PH: 888-782-7483
SAFETY INSTRUCTIONS! This is the safety alert symbol. When you see this symbol on your pump or in this manual, look for one of the following signal words and be alert to the potential for personal injury. warns about hazards that will cause serious personal injury, death or major property damage if ignored. warns about hazards that can cause serious personal injury, death or major property damage if ignored. warns about hazards that will or can cause minor personal injury or property damage if ignored. The label NOTICE indicates special instructions which are important but not related to hazards. Carefully read and follow all safety instructions in this manual and on pump. Keep safety labels in good condition. Replace missing or damaged safety labels. California Proposition 65 Warning This product and related accessories contain chemicals known to the State of California to cause cancer, birth defects or other reproductive harm. GENERAL SAFETY Do not touch an operating motor. Modern motors can operate at high temperatures. To avoid burns when servicing pump, allow it to cool for 20 minutes after shut-down before handling. Pump is designed as a lawn sprinkler only. To avoid heat built-up, over pressure hazard and possible injury, do not use in a pressure tank (domestic water) system. Do not use as a booster pump; pressurized suction may cause pump body to explode. Do not allow pump or piping system to freeze. Freezing can damage pump and pipe, may lead to injury from equipment failure and will void warranty. Pump water only with this pump. Periodically inspect pump and system components. Wear safety glasses at all times when working on pumps. Keep work area clean, uncluttered and properly lighted; store properly all unused tools and equipment. Keep visitors at a safe distance from the work areas. Make workshops childproof; use padlocks and master switches; remove starter keys. WARNING Hazardous pressure! Install pressure relief valve in discharge pipe. Release all pressure on system before working on any component. WARNING Hazardous voltage. Can shock, burn, or cause death. Ground pump before connecting to power supply. Wire motor for correct voltage. See “Electri cal” section of this manual and motor nameplate. Ground motor before connecting to power supply. Meet National Electri cal Code, Canadian Elec tri cal Code, and local codes for all wiring. Follow wiring instructions in this manual when connecting motor to power lines. ELECTRICAL SAFETY
Thank you for purchasing a top quality, factory tested pump. Page Limited Warranty STA-RITE warrants to the original consumer purchaser (“Purchaser” or “You”) of the products listed below, that they will be free from defects in material and workmanship for the Warranty Period shown below. Product Warranty Period Water Systems Products — jet pumps, small centrifugal pumps, submersible pumps and related accessories whichever occurs first: 12 months from date of original installation, or 18 months from date of manufacture Pro-Source™ Composite Tanks 5 years from date of original installation Pro-Source™ Steel Pressure Tanks 5 years from date of original installation Pro-Source™ Epoxy-Lined Tanks 3 years from date of original installation Sump/Sewage/Effluent Products 12 months from date of original installation, or 18 months from date of manufacture Our warranty will not apply to any product that, in our sole judgement, has been subject to negligence, misapplication, improper installation, or improper maintenance. Without limiting the foregoing, operating a three phase motor with single phase power through a phase converter will void the warranty. Note also that three phase motors must be protected by three-leg, ambient compensated, extra-quick trip overload relays of the recommended size or the warranty is void. Your only remedy, and STA-RITE’s only duty, is that STA-RITE repair or replace defective products (at STA-RITE’s choice). You must pay all labor and shipping charges associated with this warranty and must request warranty service through the installing dealer as soon as a problem is discovered. No request for service will be accepted if received after the Warranty Period has expired. This warranty is not transferable. STA-RITE SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER. THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THE FOREGOING WARRANTIES SHALL NOT EXTEND BEYOND THE DURATION EXPRESSLY PROVIDED HEREIN. Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on the duration of an implied warranty, so the above limitations or exclusions may not apply to You. This warranty gives You specific legal rights and You may also have other rights which vary from state to state. This Limited Warranty is effective June 1, 2011 and replaces all undated warranties and warranties dated before June 1, 2011. STA-RITE INDUSTRIES 293 Wright Street • Delavan, WI U.S.A. 53115 Phone: 1-888-782-7483 • Fax: 1-800-426-9446 • Web Site: sta-rite.com
SYMPTOM POSSIBLE CAUSE(S) CORRECTIVE ACTION Motor will not run Disconnect switch is off Be sure switch is on Fuse is blown Replace fuse Starting switch is defective Replace starting switch Wires at motor are loose, Refer to instructions on wiring. Check and tighten all wiring. disconnected, or wired incorrectly Capacitor voltage may be hazardous. To discharge capacitor, hold insulated handle screwdriver BY THE HANDLE and short capacitor terminals together. Do not touch metal screwdriver blade or capacitor terminals. If in doubt, consult a qualified electrician. Motor runs hot and Motor is wired incorrectly Refer to instructions on wiring overload kicks off Voltage is too low Check with power company. Install heavier wiring if wire size is too small (See Electrical, Page 6) Motor runs but no *Pump in new installation did In new installation: water is delivered not pick up prime through: 1. Improper priming 1. Re-prime according to instructions 2. Air leaks 2. Check all connections on suction line 3. Leaking foot valve 3. Replace foot valve *Pump has lost prime through: In installation already in use: 1. Air leaks 1. Check all connections on suction line and shaft seal 2. Water level below suction of pump 2. Lower suction line into water and re-prime. If receding water level in well exceeds suction lift, a deep well pump is needed Impeller is plugged Clean impeller; see Maintenance Check valve or foot valve is stuck Replace check valve or foot valve in closed position Pipes are frozen Thaw pipes. Bury pipes below frost line. Heat pit or pump house. Foot valve and/or strainer are Raise foot valve and/or strainer above well bottom buried in sand or mud Pump does not Water level in well is lower than A deep well jet pump may be needed (over 20 ft. to water) deliver water to full estimated capacity (Also Steel piping (if used) is corroded or Replace with plastic pipe where possible, otherwise with new steel pipe check point 3 limed, causing excess friction immediately above) Offset piping is too small in size Use larger offset piping *(Notice: Check prime before looking for other causes. Unscrew priming plug and see if there is water in priming hole.)
- Not illustrated. * Model DS3HHG3-01 uses Base C4-82. 3621 1199SPC 7A11 MODEL NUMBER DS3HE-01 DS3HF-01 DS3HG-01 DS3HHG-01 Key Part DS3HE3-01 DS3HF3-01 DS3HG3-01 DS3HHG3-01 No. Description Qty. 1 HP 1-1/2 HP 2 HP 2-1/2 HP
1 Motor, 115/230V, 1 Phase 1 J218-596PKG J218-601PKG J218-883APKG J218-628A
1 Motor, 230/460V, 3 Phase 1 AP100EL AP100FL AP100GL AP100G5L
2 Water Slinger 1 17351-0009 17351-0009 17351-0009 17351-0009
3 Seal Plate 1 C3-155 C3-155 C3-117 C3-117
4 Gasket - Seal Plate 1 C20-86 C20-86 C20-87 C20-87
5 Shaft Seal 1 U109-6A U109-6A U109-6A U109-6A
6 Impeller (1 Phase) 1 C105-92PKB C105-92PC C105-214PDA C105-214PA
6 Impeller (3 Phase) 1 C105-92PKBA C105-92PCA C105-214PDA C105-214PA
6A Impeller Screw (1 Phase) 1 — — C30-14SS C30-14SS 6A Impeller Screw (3 Phase) 1 C30-14SS C30-14SS C30-14SS C30-14SS
7 Diffuser 1 C101-276P C101-276P C101-182 C101-182
7A Screw 10-24 x1” Lg Hex Head 2 U30-696SS U30-696SS — — 7A Machine screw 8-32x7/8” Lg. 2 — — U30-53SS U30-53SS
8 Diffuser Ring 1 C21-10 C21-10 C21-2 C21-2
9 Pump Body Assembly 1 C76-67E C76-67E C76-68E C76-68E
10 Plug 1/4” NPT Hex Head 2 U78-941ZPV U78-941ZPV U78-941ZPV U78-941ZPV
11 Base 1 C4-82 C4-82 C4-82 C4-82A*
12 3/8-16x1-1/4” Lower Capscrew 2 U30-75ZP U30-75ZP U30-75ZP U30-75ZP 13 3/8-16x1” Upper Capscrew 2 U30-74ZP U30-74ZP U30-74ZP U30-99SS
14 Motor Pad 1 C35-5 C35-5 C35-5 C35-5
15 Capscrew 3/8-16x3/4” Lg 6 U30-72ZP U30-72ZP — —
15 Capscrew 5/16-18x3/4” Lg. 8 — — U30-60ZP U30-60ZP 16 Pipe Plug 3/4” NPT - Sq. Hd. 1 U78-60ZPS U78-60ZPS U78-60ZPS U78-60ZPS
- Lockwasher 3/8” 2 U43-12ZP U43-12ZP U43-12ZP U43-12ZP