Features
- Highest Flux per LED in the world
- Very long operating life (up to100k hours)
- Available in White, Green, Cyan, Blue, Red and Amber
- More Energy Efficient than Incandescent and most Halogen lamps
- Low voltage DC operated
- Cool beam, safe to the touch
- Instant light (less than 100 ns)
- Fully dimmable
- No UV
- Superior ESD protection Typical Applications
- Decorative flood
- Traffic lights
- Railway crossings and wayside
- Beacons Luxeon Flood is available in white, green, cyan, blue, red, and amber.
Luxeon Flood 2 Document #: DS24 (10/05) Mechanical Dimensions Circuit Diagram Notes: 1. Connector on board AMP type, code 2-179123-4 ; Mating connector – AMP receptacle housing assembly, code 173977-4. 2. Flood 12-Up has a resister component, 2.2k Ohm. 3. Drawing not to scale. 4. All dimensions are in millimeters. Flood 12-Up Flood 18-Up 25-0032 Resistor 25-0042 Flood 12-Up Flood 18-Up Resistor NTC Notes: 1. Connector on board AMP type, code 2-179123-4 ; Mating connector – AMP receptacle housing assembly, code 173977-4. 2. Flood 18-Up has an NTC component, 10k Ohm. 3. Drawing not to scale. 4. All dimensions are in millimeters.
Luxeon Flood 3 Document #: DS24 (10/05) Flux Characteristics at 350mA, Junction Temperature, T J = 25 oC Configuration Radiation Pattern Color Part Number Minimum Luminous Flux (lm) ΦV [1,2] Typical Luminous Flux (lm) ΦV [2] Test Current (mA) White LXHL-MWCE 165 300 700 Batwing Green LXHL- MMCA 165 360 700 (low dome) Cyan LXHL- MECA 165 360 700 Flood 12-up Blue[3] LXHL- MBCA 45 120 700 Red LXHL- MDCA 165 320 700 Amber LXHL- MLCA 125 300 700 Lambertian Red LXHL- MDCB 365 525 700 (high dome) Amber LXHL- MLCB 280 500 700 White LXHL- MWJE 250 450 1050 Batwing Green LXHL- MMJA 250 540 1050 (low dome) Cyan LXHL- MEJA 250 540 1050 Flood 18-up Blue [3] LXHL- MBJA 65 180 1050 Red LXHL- MDJA 250 480 1050 Amber LXHL- MLJA 190 450 1050 Lambertian Red LXHL- MDJB 550 790 1050 (high dome) Amber LXHL- MLJB 420 750 1050 Optical Characteristics at 350mA, Junction Temperature, T J = 25 oC Radiation Dominant Wavelength[1] λD or Color Temperature[2] CCT Spectral Half- width[3] (nm) temperature coefficient of dominant wavelength (nm/oC) Viewing Angle per LED[4,7] (Degrees) Pattern Color Min. Typ. Max. ∆λ1/2 ∆λD/ ∆ΤJ 2θ 1/2 White 4500 K 5500 K 10,000 K --- --- 110 Green 520 nm 530 nm 550 nm 35 0.04 110 Batwing Cyan 490 nm 505 nm 520 nm 30 0.04 110 (low dome) Blue 460 nm 470 nm 490 nm 25 0.04 110 Red 620.5 nm 625 nm 645 nm 20 0.05 110 Amber 584.5 nm 590 nm 597 nm 14 0.09 110 Lambertian Red 620.5 nm 627 nm 645 nm 20 0.05 140 (high dome) Amber 584.5 nm 590 nm 597 nm 14 0.09 140 Notes: 1. Minimum luminous flux performance guaranteed within published operating conditions. 2. Luxeon types with even higher luminous flux levels will become available in the future. Please consult your Lumileds Authorized Distributor or Lumileds sales representative for more information. 3. Minimum flux value for 470 nm devices. Due to the CIE eye response curve in the short blue wavelength range, the minimum luminous flux will vary over the Lumileds blue color range. Luminous flux will range from minimums of 35 lm for 12-Up and 50 lm for 18-Up Floods at 460nm to typicals of 190 lm for 12-Up and 280 lm for 18-Up Floods at 480nm due to this effect. Although the luminous power efficiency is lower in the short blue wavelength range, radiometric power efficiency increases as wavelength decreases. For more information, consult the Luxeon Design Guide, available upon request. Notes: 1. Dominant wavelength is derived from the CIE 1931 Chromaticity diagram and represents the perceived color. 2. CRI (Color Rendering Index) for White product types is 70. 3. Spectral width at ½ of the peak intensity. 4. θ½ is the off axis angle from lamp centerline where the luminous intensity is ½ of the peak value. 5. Luxeon Floods are not designed for direct view applications. Lumileds reserves the right to mix LEDs of different color and flux values to achieve the typical values listed above, possibly resulting in visible variation across the array. 6. All red and amber products built with Aluminum Indium Gallium Phosphide (AlInGaP). 7. All white, green, cyan, and blue products built with Indium Gallium Nitride (InGaN). 8. All power light sources represented here are IEC825 Class 2 for eye safety.
Luxeon Flood 4 Document #: DS24 (10/05) Electrical Characteristics at Junction Temperature, T J = 25 oC Flood 12-Up Radiation Forward Voltage (V) VF Dynamic resistance[1] Temp coefficient of Forward voltage[2] (mV/oC) Thermal resistance, junction to board[3] test current Pattern Color Min. Typ. Max. (Ω) RD ∆VF/ ∆TJ (oC/W) RθJ-B (mA) IF White 16 21 24 3 -12 1.7 700 Green 16 21 24 3 -12 1.7 700 Batwing Cyan 16 21 24 3 -12 1.7 700 (low dome) Blue 16 21 24 3 -12 1.7 700 Red 14 17 20 7.2 -12 1.7 700 Amber 14 17 20 7.2 -12 1.7 700 Lambertian Red 14 18 21 7.2 -12 1.9 700 (high dome) Amber 14 18 21 7.2 -12 1.9 700 Flood 18-Up Radiation Forward Voltage (V) VF Dynamic resistance[1] Temp coefficient of forward voltage[2] (mV/oC) Thermal resistance, junction to board[3] test current Pattern Color Min. Typ. Max. (Ω) RD ∆VF/ ∆TJ (oC/W) RθJ-B (mA) IF White 16 21 24 2 -12 1.1 1050 Green 16 21 24 2 -12 1.1 1050 Batwing Cyan 16 21 24 2 -12 1.1 1050 (low dome) Blue 16 21 24 2 -12 1.1 1050 Red 14 17 20 4.8 -12 1.1 1050 Amber 14 17 20 4.8 -12 1.1 1050 Lambertian Red 14 18 21 4.8 -12 1.3 1050 (high dome) Amber 14 18 21 4.8 -12 1.3 1050 Absolute Maximum Ratings Flood 12-Up Flood 18-Up Parameter White/Green/ Cyan/Blue Red/Amber White/Green/ Cyan/Blue Red/Amber DC Forward Current (mA) [1] 700 770 1050 1155 Peak Pulsed Forward Current (mA) 1000 1100 1500 1650 Average Forward Current (mA) 700 700 1050 1050 ESD Sensitivity [2] ± 16,000V HBM ± 16,000V HBM LED Junction Temperature ( oC) 135 120 135 120 Aluminum-Core PCB Temperature (oC) 105 105 105 105 Storage & Operating Temperature(oC) -40 to +105 -40 to +105 -40 to +105 -40 to +105 Notes: 1. Dynamic resistance is the inverse of the slope in linear forward voltage model for LEDs. See Figures 3a and 3b. 2. Measured between 25 oC ≤ TT J ≤ 110oC at I F = 700mA for Flood 12-Up and I F = 1050mA for Flood 18-Up. 3. To determine the junction temperature, multiply by total array power. Due to the high packing density of the Floods, the board temperature rise is significant and must always have additional heat sinking at nominal operating conditions. Notes: 1. Proper current derating must be observed to maintain junction temperature below the maximum. For more information, consult Luxeon Design Guide, available upon request. 2. LEDs are not designed to be driven in reverse bias. Please consult Lumileds’ information.
Luxeon Flood 8 Document #: DS24 (10/05) About Luxeon Luxeon is the new world of solid state lighting (LED) technology. Luxeon Power Light Source Solutions offer huge advantages over conventional lighting and huge advantages over other LED solutions. Luxeon enables partners to create and market products that, until now, were impossible to create. This means the opportunity to create products with a clear competitive advantage in the market. Products that are smaller, lighter, sleeker, cooler, and brighter. Products that are more fun to use, more efficient, and more environmentally conscious than ever before possible! Company Information Luxeon is developed, manufactured and marketed by Lumileds Lighting, LLC. Lumileds is a world-class supplier of Light Emitting Diodes (LEDs) producing billions of LEDs annually. Lumileds is a fully integrated supplier, producing core LED material in all three base colors (Red, Green, Blue) and White. Lumileds has R&D development centers in San Jose, California and Best, The Netherlands. Production capabilities in San Jose, California and Malaysia. Lumileds is pioneering the high-flux LED technology and bridging the gap between solid state LED technology and the lighting world. Lumileds is absolutely dedicated to bringing the best and brightest LED technology to enable new applications and markets in the Lighting world. Product specifications are subject to change without notice. Lumileds may make process or materials changes affecting the performance or other characteristics of Luxeon. These products supplied after such change will continue to meet published specifications, but may not be identical to products supplied as samples or under prior orders. Lumileds www.luxeon.com www.lumileds.com For technical assistance or the location of your nearest Lumileds sales office, call: Worldwide: +1 408-435-6111 US Toll free: 1-888-589-3662 Asia: 800-5864-5337 Europe: 00 800 443 88 873 Fax: +1 408-435-6855 Email us at info@lumileds.com Lumileds Lighting, U.S., LLC
370 West Trimble Road
San Jose, CA 95131