DS191 LUXEON IR Domed Line Product Datasheet ©2018 Lumileds Holding B.V. All rights reserved. The LUXEON IR Domed Line is a product line of high power infrared emitters tailored to application needs by offering a variety of products at multiple infrared wavelengths and optical radiation patterns. LUXEON IR Domed Line is designed with innovative LUXEON technology to provide industry-leading performance. Through best-in-class thermal conductivity, LUXEON IR Domed Line has excellent performance at actual operating conditions. The LUXEON IR Domed Line uses an industry standard footprint for ease of integration and upgrading existing system designs. LUXEON IR Domed Line High power infrared emitters with engineered primary optics for high efficiency and beam control FEATURES AND BENEFITS PRIMARY APPLICATIONS Available in 850nm and 940nm wavelengths to provide optimized performance for each type of application Surveillance / CCTV Radiant Power: 1350mW (850nm) and 1400mW (940nm) for a greater system performance Machine Vision Three emission patterns: 60°, 90° and 150° to address diverse application needs, high punch, long range and high uniformity 3D Scanning / Time of Flight 3.7mm x 3.7mm package with a 3 pad configuration that is compatible with the industry standard footprint to enable a direct upgrade in existing designs Biometric Identification Ultra-low Rth of 2.5°C/W, the industry’s best thermal conductivity, solves thermal challenges and supports space saving designs User Interface Control Augmented / Virtual Reality

DS191 LUXEON IR Domed Line Product Datasheet 20180109 ©2018 Lumileds Holding B.V. All rights reserved. i Table of Contents

DS191 LUXEON IR Domed Line Product Datasheet 20180109 ©2018 Lumileds Holding B.V. All rights reserved. 2 General Product Information Product Test Conditions LUXEON IR Domed Line emitters are tested and binned with a 20ms monopulse of 1000mA at a junction temperature, Tj, of 25°C. Part Number Nomenclature Part numbers for LUXEON IR Domed Line follow the convention below: L 1 I 0 – 0 A A A B B B X X X X X X Where: A A A – designates nominal peak wavelength B B B – designates full width half maximum of the emitter’s radiation pattern X X X X X X – reserved for further customization Therefore, the following part number is used for a LUXEON IR Domed emitter with a peak wavelength of 850nm and a FWHM beam angle of 60°: L 1 I 0 – 0 8 5 0 0 6 0 0 0 0 0 0 0 Radiometric Power Maintenance Please contact your local Sales Representative or Lumileds Technical Solutions Manager for more information about the long- term performance of this product. Environmental Compliance Lumileds LLC is committed to providing environmentally friendly products to the solid-state lighting market. LUXEON IR Domed Line is compliant to the European Union directives on the restriction of hazardous substances in electronic equipment, namely the RoHS Directive 2011/65/EU and REACH Regulation (EC) 1907/2006. Lumileds LLC will not intentionally add the following restricted materials to its products: lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls (PBB) or polybrominated diphenyl ethers (PBDE).

DS191 LUXEON IR Domed Line Product Datasheet 20180109 ©2018 Lumileds Holding B.V. All rights reserved. 3 Performance Characteristics Product Selection Guide Table 1 . Product performance and optical characteristics of LUXEON IR Domed Line at 1000mA, T j=25°C . PEAK WAVELENGTH [1] (nm) TYPICAL FWHM BEAM ANGLE (°) RADIOMETRIC POWER [2] (mW) TYPICAL RADIANT INTENSITY (mW/sr) TYPICAL SPECTRUM FWHM (nm) PART NUMBER MINIMUM TYPICAL 850 150 1000 1350 335 35 L1I0-0850150000000 850 90 1000 1350 750 35 L1I0-0850090000000 850 60 1000 1350 1150 35 L1I0-0850060000000 940 150 1100 1450 350 50 L1I0-0940150000000 940 90 1100 1450 780 50 L1I0-0940090000000 940 60 1100 1450 1190 50 L1I0-0940060000000 Notes for Table 1: 1. Lumileds maintains a tolerance of ±0.5nm on peak wavelength measurements. 2. Lumileds maintains a tolerance of ±7% on radiometric power measurements. Electrical and Thermal Characteristics Table 2 . Electrical and thermal characteristics for LUXEON IR Domed Line at 1000mA, T j=25°C . PART NUMBER FORWARD VOLTAGE [1] (Vf) TYPICAL TEMPERATURE COEFFICIENT OF FORWARD VOLTAGE [2] (mV/°C) TYPICAL TEMPERATURE COEFFICIENT OF PEAK WAVELENGTH [2] (nm/°C) TYPICAL THERMAL RESISTANCE—JUNCTION TO SOLDER PAD (°C/W)MINIMUM TYPICAL MAXIMUM Notes for Table 2: 1. Lumileds maintains a tolerance of ±1% on forward voltage measurements. 2. Measured between 25°C and 85°C. Absolute Maximum Ratings Table 3 . Absolute maximum ratings for LUXEON IR Domed Line . PARAMETER MAXIMUM PERFORMANCE DC Forward Current [1, 2] 1000mA Peak Pulsed Forward Current [1, 3] 3000mA Emitter Junction Temperature [1] (DC & Pulse) 145°C ESD Sensitivity (ANSI/ESDA/JEDEC JS-001-2012) Class 3B Operating Case Temperature [1] -30°C to 85°C Emitter Storage Temperature -40°C to 125°C SMD Process Classification Temperature 260°C per JEDEC J-STD-020E Allowable Reflow Cycles 3 Reverse Voltage (Vreverse) LUXEON IR LEDs are not designed to be driven in reverse bias Notes for Table 3: 1. Proper current derating must be observed to maintain the junction temperature below the maximum allowable junction temperature. 2. Residual periodic variations due to power conversion from alternating current (AC) to direct current (DC), also called “ripple,” are acceptable if the following conditions are met: – The frequency of the ripple current is 100Hz or higher – The average current for each cycle does not exceed the maximum allowable DC forward current – The maximum amplitude of the ripple does not exceed the maximum peak pulsed forward current 3. For pulse handling capability details see figure 9.

DS191 LUXEON IR Domed Line Product Datasheet 20180109 ©2018 Lumileds Holding B.V. All rights reserved. 8 Permissible Pulse Handling Characteristics Figure 9 . Permissible pulse handling capability for LUXEON IR Domed Line at T j=85°C . 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 1E-5 1E-4 1E-3 1E-2 1E-1 1E+0 1E+1 1E+2 ]A[ tnerruC drawroF Pulse Width [s] D = 0.005 D = 0.01 D = 0.02 D = 0.05 D = 0.10 D = 0.20 D = 0.50 D = 0.75 85°C

dominant wavelength and forward voltage. product availability in a particular bin varies by production run and by product performance. Not all bins are available in all CCTs. Table 4. Radiometric power bin definitions for LUXEON IR Domed Line at 1000mA, T j=25°C .

  1. Lumileds maintains a tolerance of ±7% on radiometric power measurements.

Table 5. Peak wavelength bins for LUXEON IR Domed Line at 1000mA, T j=25°C .

  1. Lumileds maintains a tolerance of ±0.5nm on peak wavelength measurements.

Table 6. Forward voltage bin definitions for LUXEON IR Domed Line at 1000mA, T j=25°C .

  1. Lumileds maintains a tolerance of ±1% on forward voltage measurements.

DS191 LUXEON IR Domed Line Product Datasheet 20180109 ©2018 Lumileds Holding B.V. All rights reserved. 11 Mechanical Dimensions Figure 10 . Mechanical dimensions for LUXEON IR Domed Line . L1I0-0XXX060000000 L1I0-0XXX090000000 L1I0-0XXX150000000 R1.40 2.96 ±0.10* SIDE VIEWR1.50 1.80 ±0.10* R1.50 2.77 ±0.10* TOP VIEW Theoretical Optical Center 3.70 ±0.10* 3.70 ±0.10* BACK VIEW CATHODE ANODE ANODE 2.70 (3x) 0.500.50 0.35 1.00 0.35 2.70 CATHODE INDICATOR Notes for Figure 10: 1. Drawings are not to scale. 2. All dimensions are in millimeters.

Table 7. Reflow profile characteristics for LUXEON IR Domed Line. Table 8 . Moisture sensitivity levels for LUXEON IR Domed Line .

1 Unlimited ≤30°C / 85% RH 168 Hours +5 / -0 85°C / 85% RH

Figure 11. Visualization of the acceptable reflow temperature profile as specified in Table 7.

DS191 LUXEON IR Domed Line Product Datasheet 20180109 ©2018 Lumileds Holding B.V. All rights reserved. LUXEON is a registered trademark of the Lumileds Holding B.V. in the United States and other countries. lumileds.com Neither Lumileds Holding B.V. nor its affiliates shall be liable for any kind of loss of data or any other damages, direct, indirect or consequential, resulting from the use of the provided information and data. Although Lumileds Holding B.V. and/or its affiliates have attempted to provide the most accurate information and data, the materials and services information and data are provided “as is,” and neither Lumileds Holding B.V. nor its affiliates warrants or guarantees the contents and correctness of the provided information and data. Lumileds Holding B.V. and its affiliates reserve the right to make changes without notice. You as user agree to this disclaimer and user agreement with the download or use of the provided materials, information and data. A listing of Lumileds product/patent coverage may be accessed at lumileds.com/patents. About Lumileds Companies developing automotive, mobile, IoT and illumination lighting applications need a partner who can collaborate with them to push the boundaries of light. With over 100 years of inventions and industry firsts, Lumileds is a global lighting solutions company that helps customers around the world deliver differentiated solutions to gain and maintain a competitive edge. As the inventor of Xenon technology, a pioneer in halogen lighting and the leader in high performance LEDs, Lumileds builds innovation, quality and reliability into its technology, products and every customer engagement. Together with its customers, Lumileds is making the world safer, better and more beautiful—with light. To learn more about our lighting solutions, visit lumileds.com.