FEATURES
Temperature Measurements Require No External Components Measures Temperatures from -55°C to +120°C. Fahrenheit Equivalent is -67°F to +248°F Thermometer Accuracy is ±2.0°C Thermometer Resolution is Configurable from 8 to 12 bits (1.0°C to 0.0625°C Resolution) Data is Read From/Written to Via a Motorola Serial Peripheral Interface (SPI) or Standard 3-Wire Serial Interface Wide Analog Power Supply Range (2.65V - 5.5V) Separate Digital Supply Allows for 1.8V Logic Available in an 8-Pin SO (150mil), 8-Pin μMAX, and Flip-Chip Package PIN ASSIGNMENT PIN DESCRIPTION SERMODE - Serial Interface Mode CE - Chip Enable SCLK - Serial Clock GND - Ground V DDA - Analog Supply Voltage SDO - Serial Data Out SDI - Serial Data In V DDD - Digital Supply Voltage
DESCRIPTION
The DS1722 Digital Thermometer and Thermostat wi th SPI/3-Wire Interface provides temperature readings which indicate the temperature of the device. No additional components are required; the device is truly a temperature-to-digital converter. Temperature readings are communicated from the DS1722 over a Motorola SPI interface or a sta ndard 3-wire serial interface. The choice of interface standard is selectable by the user. For applications that require grea ter temperature resolution, the user can adjust the readout resolution from 8 to 12 bits. This is particularly useful in applications where thermal runaway conditions must be detected quickly. For application flexibility, the DS1722 features a wi de analog supply rail of 2.65V - 5.5V. A separate digital supply allows a range of 1.8V to 5.5V. The DS1722 is available in an 8-pin SO (150mil), 8-pin μMAX, and flip-chip package. equipment, or any thermally-sensitive system. DS1722 Digital Thermometer with SPI/3-Wire Interface www.maxim-ic.com VDDD CE SCLK GND VDDA DS1722S 8-Pin SO (150mil) SERMODE SDI SDO 1 8 2 7 3 6 4 5 DS1722U 8-PIN µMAX VDDA SERMODE SDI SDO VDDD CE SCLK GND
ORDERING INFORMATION Table 1 PART MARKING DESCRIPTION DS1722S DS1722 DS1722 in 150mil 8-Pin SO DS1722S/T&R DS1722 DS1722 in 150mil 8-Pin SO, 2500 Piece Tape-and- Reel DS1722S+ DS1722 (See note) DS1722 in Lead-Free 150mil 8-Pin SO DS1722S+T&R DS1722 (See note) DS1722 in Lead-Free 150mil 8-Pin SO, 2500 Piece Tape-and-Reel DS1722U 1722 DS1722 in 8-Pin µMAX DS1722U/T&R 1722 DS1722 in 8-Pin µMAX, 3000 Piece Tape-and- Reel DS1722U+ 1722 (See note) DS1722 in Lead-Free 8-Pin µMAX DS1722U+T&R 1722 (See note) DS1722 in Lead-Free 8-Pin µMAX, 3000 Piece Tape-and-Reel Note: A “+” will also be marked on the package next to the pin 1 indicator. DETAILED PIN DESCRIPTION Table 2 SOIC SYMBOL DESCRIPTION PIN 1 VDDD Digital Supply Voltage 1.8V-5.5V. Defines the top rails for the digital inputs and outputs. PIN 2 CE Chip Enable Must be asserted high for co mmunication to ta ke place for either the SPI or 3-wire interface. PIN 3 SCLK Serial Clock Input Used to synchronize data movement on the serial interface for either the SPI or 3-wire interface. PIN 4 GND Ground pin. PIN 5 SDO Serial Data Output When SPI communication is selected, the SDO pin is the serial data output for the SPI bus. When 3-wire communication is selected, this pin must be tied to the SDI pin (the SDI and SDO pins function as a single I/O pin when tied together.) PIN 6 SDI Serial Data Input When SPI communication is se lected, the SDI pin is the serial data input for th e SPI bus. When 3-wire communication is selected, this pin must be tied to the SDO pin (the SDI and SDO pins function as a single I/O pin when tied together.) PIN 7 SERMODE Serial Interface Mode Input This pin selects which interface standard will be used: SPI when connected to V CC ; standard 3-wire when connected to GND. PIN 8 VDDA Analog Supply Voltage 2.65V – 5.5V input power pin.
A block diagram of the DS1722 is shown in Figure 1. The DS1722 consists of four major components: 1. Precision temperature sensor 2. Analog-to-digital converter 3. SPI/3-wire interface electronics 4. Data registers The factory-calibrated temperature sensor requires no external com ponents. The DS1722 is in a power- conserving shutdown state upon power- up. After power-up, the user may al ter the configuration register to place the device in a continuous temperature conversion mode or in a one-shot conversion mode. In the continuous conversion mode, th e DS1722 continuously converts the temp erature and stores the result in the temperature register. As conversions are performed in th e background, reading the temperature register does not affect the conversion in progress. In the one-shot temperature conversion mode, the DS1722 will perform one temperature conversion, store th e result in the temperature register, and then return to the shutdown state. Th is conversion mode is ideal for po wer sensitive applications. More information on the configuration register is contained in the “OPERATION-Programming” section. The temperature conversion results will have a default resolution of 9 bits. In applications where small incremental temperature changes are critical, the user can change the conversion resolution from 9 bits to 8, 10, 11, or 12. This is accomplished by programming the configuration register. Each additional bit of resolution approximately doubles the conversion time. The DS1722 can communicate using either a Motorola Se rial Peripheral Interfac e (SPI) or standard 3- wire interface. The user can select either communication standard through the SERMODE pin, tying it to V DDD for SPI and to ground for 3-wire. The device contains both an analog suppl y voltage and a digi tal supply voltage (V DDA and V DDD, respectively). The analog supply powers the device fo r operation while the dig ital supply provides the top rails for the digital inputs and outputs. The DS1722 was designed to be 1.8V Logic-Ready.
DS1722 FUNCTIONAL BLOCK DIAGRAM Figure 1 OPERATION-Measuring Temperature The core of DS1722 functionality is its direct-to- digital temperature sens or. The DS1722 measures temperature through the use of an on-chip temperat ure measurement technique with an operating range from -55° to +120°C. The device powers up in a power-conserving shutdown mode. After power-up, the DS1722 may be placed in a contin uous conversion mode or in a one-shot conversion mode. In the continuous conversion mode, the de vice continuously comput es the temperature a nd stores the most recent result in the temperature register at a ddresses 01h (LSB) and 02h (MSB). In the one-shot conversion mode, the DS1722 performs one temperatur e conversion and then re turns to the shutdown mode, storing temperature in the te mperature register. Details on how to change the setting after power- up are contained in the “OPERATION-Programming” section. The resolution of the temperature conve rsion is configurable (8, 9, 10, 11, or 12 bits), with 9-bit readings Following each conversion, thermal da ta is stored in the thermomete r register in two’s complement format; the information can be retrieved over the SPI or 3-wire interface with the address set to the temperature register, 01h (LSB) and then 02h (MSB). Table 3 describes the exact relationship of output data to measured temperature. The table assumes th e DS1722 is configured for 12-bit resolution; if the device is configured in a lower resolution mode, t hose bits will contain 0s. The data is transmitted serially over the digital interface, MSb first for SPI communication and LSb first for 3-wire communication. The MSb of the temper ature register contains the “si gn” (S) bit, denoting whether the temperature is positive or negative. For Fahrenheit usage, a lookup tabl e or conversion routine must be used.
Temperature/Data Relationships Table 3 Address Location S 2 6 25 24 23 22 21 20 02h M S b ( u n i t = °C) LSb 2-1 2-2 2-3 2-4 0 0 0 0 01h TEMPERATURE DIGITAL OUTPUT (BINARY) DIGITAL OUTPUT (HEX) +120°C 0111 1000 0000 0000 7800h +25.0625°C 0001 1001 0001 0000 1910h +10.125°C 0000 1010 0010 0000 0A20h +0.5°C 0000 0000 1000 0000 0080h 0°C 0000 0000 0000 0000 0000h -0.5°C 1111 1111 1000 0000 FF80h -10.125°C 1111 0101 1110 0000 F5E0h -25.0625°C 1110 0110 1111 0000 E6F0h -55°C 1100 1001 0000 0000 C900h OPERATION-Programming The area of interest in programming the DS1722 is the Configurat ion register. All programming is done via the SPI or 3-wire communication interface by select ing the appropriate address of the desired register location. Table 4 illustrates the ad dresses for the two registers (config uration and temperature) of the DS1722. Register Address Structure Table 4 Read Address Write Address Active Register 00h 80h Configuration 01h No access Temperature LSB 02h No access Temperature MSB CONFIGURATION REGISTER PROGRAMMING The configuration register is ac cessed in the DS1722 with the 00h addr ess for reads and the 80h address for writes. Data is read from or written to the configuration register MSb first for SPI communication and LSb first for 3-wire communication. The format of the re gister is illustrated in Figure 2. The effect each bit has on DS1722 functionality is described below along with the power-up state of the bit. The entire register is volatile, and thus it will power-up in the default state.
CONFIGURATION/STATUS REGISTER Figure 2 1 1 1 1SHOT R2 R1 R0 SD MSb LSb 1SHOT = One-shot temperature conversio n bit. If the SD bit is "1", (continuous temperature conversions are not taking place), a "1" written to the 1SHOT bit will cause the DS1722 to perform one temperature conversion and store the results in the temperature register at addresses 01h (LSB) and 02h (MSB). The bit will clear itsel f to "0" upon completion of the temp erature conversion. The user has read/write access to the 1SHOT bit, although writes to this bit will be ignored if the SD bit is a "0", (continuous conversion mode). The power-up default of the one-shot bit is "0". R0, R1, R2 = Thermometer resolution bits. Table 5 belo w defines the resolution of the digital thermometer, based on the settings of these 3 bits. There is a direct tradeoff between resolution and conversion time, as depicted in the AC Electrical Characteristics. The user has read/wri te access to the R2, R1 and R0 bits and the power-up default state is R2="0", R1="0", and R0="1" (9-bit conversions). THERMOMETER RESOLUTION CONFIGURATION Table 5 R2 R1 R0 Thermometer Resolution Max Conversion Time 0 0 0 8-bit 0.075s 0 0 1 9-bit 0.15s 0 1 0 10-bit 0.3s 0 1 1 11-bit 0.6s 1 x x 12-bit 1.2s x=Don’t care. SD = Shutdown bit. If SD is "0", the DS1722 will continuously perf orm temperature conversions and store the last completed result in the temperature regi ster. If SD is changed to a "1", the conversion in progress will be completed and stored and then the device will revert to a low-power shutdown mode. The communication port remains active. The user ha s read/write access to the SD bit and the power-up default is "1" (shutdown mode). SERIAL INTERFACE The DS1722 offers the flexibility to choose between two serial interface modes. The DS1722 can communicate with the SPI interface or with a standard 3-wire interf ace. The interface method used is determined by the SERMODE pin. When this pin is connected to V DDD SPI communication is selected. When this pin is connected to ground, standard 3-wire communication is selected. SERIAL PERIPHERAL INTERFACE (SPI) The serial peripheral interface (SPI) is a synchronous bus for address and data transfer. The SPI mode of serial communication is selected by tying the SERMODE pin to V DDD. Four pins are used for the SPI. The four pins are the SDO (Serial Data Out), SDI (Ser ial Data In), CE (Chip Enable), and SCLK (Serial Clock). The DS1722 is the slave device in an SPI application, with the microcontroller being the master. The SDI and SDO pins are the serial data input and output pins for the DS 1722, respectively. The CE input is used to initiate and terminate a data tran sfer. The SCLK pin is used to synchronize data movement between the master (microcontroller) and the slave (DS1722) devices. The shift clock (SCLK), which is ge nerated by the microcon troller, is active only when CE is high and during address and data transfer to any device on the SPI bus. The inactive clock polarity is programmable in some microcontrollers. The DS1722 offers an important feature in that the level of the
inactive clock is determined by sampling SCLK when CE becomes active. Therefore, either SCLK polarity can be accommodated. Input da ta (SDI) is latched on the intern al strobe edge and output data (SDO) is shifted out on the shift edge (See Table 6 and Figure 3). There is one clock for each bit transferred. Address and data bits are transferred in groups of eight, MSB first. FUNCTION TABLE Table 6 MODE CE SCLK SDI SDO Disable Reset L Input Disabl ed Input Disabled High Z Write H CPOL=1* CPOL=0 Data Bit Latch High Z Read H CPOL=1 CPOL=0 X Next data bit shift** *CPOL is the “Clock Polarity” bit that is set in the control register of the microcontroller. ** SDO remains at High Z until eight bits of data are ready to be shifted out during a read. NOTE: CPHA bit polarity must be set to “1”. SERIAL CLOCK AS A FUNCTION OF MICROCONTROLLER CLOCK POLARITY (CPOL) Figure 3 CPOL=1 CPOL=0 NOTE: CPOL is a bit that is set in the microcontroller’s Control Register. ADDRESS AND DATA BYTES Address and data bytes are shifted MSB first into the serial data input (SDI) a nd out of the serial data output (SDO). Any transfer require s the address of the byte to specify a write or a read, followed by one or more bytes of data. Data is transferred out of the SDO for a read operation and into the SDI for a write operation. CE SCLK CE SCLK INTERNAL STROBESHIFT INTERNAL STROBESHIFT
SPI SINGLE BYTE WRITE Figure 4 The address byte is always the first byte entered after CE is driven high. The most significant bit (A7) of this byte determines if a read or write will take place. If A7 is "0", one or more read cycles will occur. If A7 is "1", one or more write cycles will occur. Data transfers can occur 1 byte at a time in multiple-b yte burst mode. After CE is driven high an address is written to the DS1722. Af ter the address, one or more data bytes can be written or read. For a single- byte transfer, 1 byte is read or writ ten and then CE is driven low (s ee Figures 4 and 5). For a multiple- byte transfer, however, multiple byte s can be read or written to th e DS1722 after the address has been written (see Figure 6). A single-byte burst read/wri te will sequentially point through the memory map and will loop from 02h/82h to 00h/80h. SPI MULTIPLE BYTE BURST TRANSFER Figure 6 SPI SINGLE-BYTE READ Figure 5
The 3-wire communication mode operate s similar to the SPI mode. Howe ver, in 3-wire mode, there is one bi-directional I/O instead of separate data in and data out signals. The 3-wire consists of the I/O (SDI and SDO pins tied together), CE, and SCLK pins. In 3-wire mode, each byte is shifted in LSB first unlike SPI mode where each byte is shif ted in MSB first. As is the ca se with the SPI mode, an address byte is written to the device followed by a single data byte or multiple data bytes. Figure 7 illustrates a read and write cycle. Figure 8 illustrates a multiple byt e burst transfer. In 3-wire mode, data is input on the rising edge of SCLK and output on the falling edge of SCLK. 3-WIRE SINGLE BYTE TRANSFER Figure 7 3-WIRE MULTIPLE BYTE BURST TRANSFER Figure 8
ABSOLUTE MAXIMUM RATINGS* Voltage on V DD , Relative to Ground -0.3V to +6.0V Voltage on any other pin, Relative to Ground -0.3V to +6.0V Operating Temperature -55 °C to +125°C Storage Temperature -55 °C to +125°C Soldering Temperature 260°C for 10 seconds * This is a stress rating only and functional operation of the device at these or any other conditions above those indicated in the operation s ections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods of time may affect reliability. The Dallas Semiconductor DS1722 is built to the highest quality standards and manufactured for long term reliability. All Dallas Semiconductor devices are made using the same quality materials and manufacturing methods. However, the DS1722 is not exposed to environmental stresses, such as burn-in, that some industrial applications require. For specific reliability in formation on this product, please contact the factory in Dallas at (972) 371-4448. RECOMMENDED DC OPERATING CONDITIONS (-55°C to +120°C, 2.65V ≤ VDDA ≤5.5V) PARAMETER SYMBOL CONDITION MIN TYP MAX UNITS NOTES Analog Supply Voltage V DDA 2.65 5.5 V 1 Digital Supply Voltage V DDD 1.8 5.5 V 1 DC ELECTRICAL CHARACTERISTICS (-55 °C to +120°C, 2.65V ≤ VDDA ≤ 5.5V) PARAMETER SYMBOL CONDITION MIN TYP MAX UNITS NOTES Input Logic High V IH 0.7 x VDDD V 1 Input Logic Low V IL 0.2 x VDDD V 1 Logic 0 Output V OL 0.2 x VDDD V 2 Logic 1 Output V OH 0.7 x VDDD V 3 Input Resistance R I CE to GND SDI, SDO, SCLK to VDDD MΩ MΩ Active Current I CC .5 mA 4 Shutdown Current I CC 2.65V ≤ VDDA ≤ 3.3V 3.3V≤VDDA≤5.5V 0.5 1.0 µA µA
ELECTRICAL CHARACTERISTICS: DIGITAL THERMOMETER (-55°C to +120°C, 2.65V ≤ VDDA ≤ 5.5V) PARAMETER SYMBOL CONDITION MIN TYP MAX UNITS NOTES -40°C to +85°C ±2.0 Thermometer Error T ERR Resolution 8 12 bits 8-bit conversions 67.5 75 9-bit conversions 125 150 10-bit conversions 250 300 11-bit conversions 500 600 Conversion Time t CONVT 12-bit conversions 1000 1200 ms AC ELECTRICAL CHARACTERISTICS: 3-WIRE INTERFACE PARAMETER SYMBOL CONDITION MIN TYP MAX UNITS NOTES Data to SCLK Setup t DC 35 ns 5, 6 SCLK to Data Hold t CDH 35 ns 5, 6 SCLK to Data Valid t CDD 80 ns 5, 6, 7 SCLK Low Time t CL 100 ns 6 SCLK High Time t CH 100 ns 6 SCLK Frequency t CLK DC 5.0 MHz 6 SCLK Rise and Fall t R, tF 200 ns CE to SCLK Setup t CC 400 ns 6 SCLK to CE Hold t CCH 100 ns 6 CE Inactive Time t CWH 400 ns 6 CE to Output High Z t CDZ 40 ns 5, 6 SCLK to Output High Z t CCZ 40 ns 5, 6 TIMING DIAGRAM: 3-WIRE READ DATA TRANSFER Figure 9
TIMING DIAGRAM: 3-WIRE WRITE DATA TRANSFER Figure 10 *I/O is SDI and SDO tied together. AC ELECTRICAL CHARACTERISTICS: SPI Interface PARAMETER SYMBOL CONDITION MIN TYP MAX UNITS NOTES Data to SCLK Setup t DC 35 ns 5, 6 SCLK to Data Hold t CDH 35 ns 5, 6 SCLK to Data Valid t CDD 80 ns 5, 6, 7 SCLK Low Time t CL 100 ns 6 SCLK High Time t CH 100 ns 6 SCLK Frequency t CLK DC 5.0 MHz 6 SCLK Rise and Fall t R, tF 200 ns CE to SCLK Setup t CC 400 ns 6 SCLK to CE Hold t CCH 100 ns 6 CE Inactive Time t CWH 400 ns 6 CE to Output High Z t CDZ 40 ns 5, 6 TIMING DIAGRAM: SPI READ DATA TRANSFER Figure 11
TIMING DIAGRAM: SPI WRITE DATA TRANSFER Figure 12 *SCLK can be either polarity, timing shown for CPOL = 1. NOTES: 1. All voltages are referenced to ground. 2. Logic 0 voltages are specified at a sink current of 3 mA. 3. Logic 1 voltages are specified at a source current of 1 mA. 4. I CC specified with SCLK=V DDD and CE=GND. Typical I CC1 is 0.25 µA and I CC is 0.3 mA at 25°C and VDDD = 2.65V. 5. Measured at V IH =0.7 VDDD or VIL=0.2 VDDD and 10 ms maximum rise and fall time. 6. Measured with 50 pF load 7. Measured at V OH =0.7 V DDD or V OL =0.2 VDDD. Measured from the 50% point of SCLK to the V OH minimum of SDO.
TYPICAL DS1722 THERMOMETER ERROR
REVISION HISTORY
Pages changed at Rev 052307: 1, 2, 11, 13, 14. Pages changed at Rev 103007: 15. -1.75 -1.5 -1.25 -0.75 -0.5 -0.25 0.25 0.5 0.75 1.25 1.5 1.75 - 2 0 - 1 5 - 1 0- 5 0 5 1 01 52 02 53 03 54 04 55 05 56 06 57 07 58 08 5 Ref Temp(C) Error(C) Mean +3σ -3σ