Features
- Compact high flux density light source
- Uniform high quality illumination
- Streamlined thermal path
- Energy Star / ANSI compliant binning structure
- More energy efficient than incandescent, halogen and fluorescent lamps
- Low voltage DC operation
- Instant light with unlimited dimming
- 5-year warranty
- RoHS compliant and Pb free Benefits
- Enhanced optical control
- Clean white light without pixilation
- Significantly reduced thermal resistance and increased operating temperatures
- Uniform consistent white light
- Lower operating costs
- Increased safety
- Easy to use with daylight and motion detectors to enable increased energy savings
- Reduced maintenance costs
- Environmentally friendly, no disposal issue
Bridgelux RS Array Series Product Data Sheet DS16 (3/14/11) Page 2 of 32 Table of Contents Page Product Nomenclature 3 Average Lumen Maintenance Characteristics 3 Environmental Compliance 3 UL Recognition 4 Minor Product Change Policy 4 Cautionary Statements 4 Case Temperature Measurement Point 5 Flux Characteristics 6 Optical Characteristics 7 Electrical Characteristics 8 Absolute Minimum and Maximum Ratings 9 Typical Performance at Alternative Drive Currents 10 Mechanical Dimensions 12 Typical Radiation Pattern 13 Wavelength Characteristics at Rated Test Current, Tj=25°C 14 Typical Relative Luminous Flux vs. Current, Tj=25° C 16 Typical Light Output Characteristics vs. Temperature 17 Typical Chromaticity Characteristics vs. Temperature 18 Typical Forward Current Characteristics at Tj = 25°C 19 Current Derating Curves 20 Product Binning 21 Color Binning Information 22 Mechanical Assembly and Handling 25 Product Packaging and Labeling 27 Packaging Tube Design 30 Design Resources 31
Bridgelux RS Array Series Product Data Sheet DS16 (3/14/11) Page 3 of 32 Product Nomenclature The part number designation for Bridgelux LED Arrays is explained as follows: B X R A – A B C D E – R R R R R Where: B X R A – designates product family A – designates color, C for Cool White, N for Neutral White and W for Warm White B C D – designates LED Array product flux, 300 for a 3000 lumen array, etc E – designates product family R R R R R – used to designate product options, 00000 by default The base product part number (BXRA-ABCDE) is indicated on each individual unit, printed on the bottom of the LED Array. Average Lumen Maintenance Characteristics Bridgelux projects that its family of LED Array products will deliver, on average, greater than 70% lumen maintenance after 50,000 hours of operation at the rated forward test current. This performance assumes constant current operation with case temperature maintained at or below 70°C. For use beyond these typical operating conditions please consult your Bridgelux sales representative for further assistance. These projections are based on a combination of package test data, semiconductor chip reliability data, a fundamental understanding of package related degradation mechanisms, and performance observed from products installed in the field using Bridgelux die technology. Bridgelux conducts lumen maintenance tests per LM80. Observation of design limits is required in order to achieve this projected lumen maintenance. Environmental Compliance Bridgelux is committed to providing environmentally friendly products to the solid-state lighting market. Bridgelux LED Arrays are compliant to the European Union directives on the restriction of hazardous substances in electronic equipment, namely the RoHS directive. Bridgelux will not intentionally add the following restricted materials to LED Array products: lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls (PBB) or polybrominated diphenyl ethers (PBDE).
Bridgelux RS Array Series Product Data Sheet DS16 (3/14/11) Page 4 of 32 UL Recognition Bridgelux has UL Recognition for all the LED Array products listed in this data sheet. Please refer to the UL file E333389 for the latest list of UL Recognized Arrays. Bridgelux uses UL Recognized materials with suitable flammability ratings in the LED Array to streamline the process for customers to secure UL listing of the final luminaire product. Bridgelux recommends that luminaires are designed with a Class 2 Driver to facilitate the UL listing process. Minor Product Change Policy The rigorous qualification testing on products offered by Bridgelux provides performance assurance. Slight cosmetic changes that do not affect form, fit, or function may occur as Bridgelux continues product optimization. Cautionary Statements CAUTION: CONTACT WITH OPTICAL AREA Contact with the resin area should be avoided. Applying stress to the resin area can result in damage to the product. CAUTION: EYE SAFETY Eye safety classification for the use of Bridgelux LED Arrays is in accordance with IEC specification EN62471; Photobiological Safety of Lamps and Lamp Systems. Bridgelux LED Arrays are classified as Risk Group 1 (Low Risk) when operated at or below their rated test current. Please use appropriate precautions. It is important that employees working with LEDs are trained to use them safely. CAUTION: RISK OF BURN Do not touch the LED Array or resin area during operation. Allow the LED Array to cool for a sufficient period of time before handling. The LED Array may reach elevated temperatures such that it can burn skin when touched.
Bridgelux RS Array Series Product Data Sheet DS16 (3/14/11) Page 5 of 32 Case Temperature Measurement Point A case temperature measurement point location is included on the top surface of the Bridgelux LED Arrays. The location of this measurement point is indicated in the mechanical dimensions section of this data sheet. The purpose of this measurement point is to allow the user access to a measurement point closely linked to the true case temperature on the back surface of the LED Array. Once the LED Array is installed, it is challenging to measure the back surface of the array, or true case temperature. Measuring the top surface of the product can lead to inaccurate results due to the poor thermal conductivity of the top layers of the array such as the solder mask and other materials. Bridgelux has provided the case temperature measurement location in a manner which closely ties it to the true case temperature of the LED Array under steady state operation. Deviations between thermal measurements taken at the point indicated and the back of the LED Array differ by less than 1°C, providing a robust method to testing thermal operation once the product is installed.
Bridgelux RS Array Series Product Data Sheet DS16 (3/14/11) Page 6 of 32 Flux Characteristics Table 1: Flux Characteristics Color ANSI CCT (K) Part Number CRI Typical Luminous Flux фv (lm), Tcase=60°C [3] Minimum Luminous Flux фv (lm), Tj=25°C [1] Typical Luminous Flux фv (lm), Tj=25°C Test Current (mA) [2] Warm White 2700K BXRA-W3500- 00S0E 80 3300 3300 3700 2100 2700K BXRA-W3500- 00S0G 90 3000 3000 3300 2100 2700K BXRA-W5700- 00S0E 80 5200 5200 5800 2800 2700K BXRA-W5700- 00S0G 90 4700 4700 5200 2800 3000K BXRA-W3500- 00Q0E 80 3600 3600 4000 2100 3000K BXRA-W3500- 00Q0G 90 3250 3250 3600 2100 3000K BXRA-W5700- 00Q0E 80 5700 5700 6300 2800 3000K BXRA-W5700- 00Q0G 90 5100 5100 5650 2800 Neutral White 4000K BXRA-N4000- 00L0E 80 4000 4000 4400 2100 4000K BXRA-N6300- 00L0E 80 6300 6300 7000 2800 Cool White 5600K BXRA-C5000- 00E0C 70 5000 5000 5600 2100 5600K BXRA-C8000- 00E0C 70 7900 7900 8800 2800 Notes for Table 1: 1. Bridgelux maintains a ± 7% tolerance of flux measurements. 2. Parts are tested in pulsed conditions, Tj = 25 °C. Pulse width is 10 ms at rated test current. 3. Typical performance wh en driven with direct current using Bridgelux test set-up. Please contact a Bridgelux sales representative for additional details
Bridgelux RS Array Series Product Data Sheet DS16 (3/14/11) Page 7 of 32 Optical Characteristics Table 2: Optical Characteristics Color ANSI CCT (K) Part Number Color Temperature (CCT) [1],[2],[3] Minimum Color Rendering Index [4] Typical Viewing Angle (Degrees) 2 θ½ [6] Typical Center Beam Candle Power (cd) [5] Min Typ Max Warm White 2700K BXRA-W3500- 00S0E 2580 K 2725 K 2870 K 80 120 1175 2700K BXRA-W3500- 00S0G 2580 K 2725 K 2870 K 90 120 1050 2700K BXRA-W5700- 00S0E 2580 K 2725 K 2870 K 80 120 1850 2700K BXRA-W5700- 00S0G 2580 K 2725 K 2870 K 90 120 1660 3000K BXRA-W3500- 00Q0E 2870 K 3045 K 3220 K 80 120 1275 3000K BXRA-W3500- 00Q0G 2870 K 3045 K 3220 K 90 120 1150 3000K BXRA-W5700- 00Q0E 2870 K 3045 K 3220 K 80 120 2000 3000K BXRA-W5700- 00Q0G 2870 K 3045 K 3220 K 90 120 1800 Neutral White 4000K BXRA-N4000- 00L0E 3700 K 4000 K 4250 K 80 120 1400 4000K BXRA-N6300- 00L0E 3700 K 4000 K 4250 K 80 120 2200 Cool White 5600K BXRA-C5000- 00E0C 5310 K 5665 K 6020 K 70 120 1780 5600K BXRA-C8000- 00E0C 5310 K 5665 K 6020 K 70 120 2800 Notes for Table 2: 1. Parts are tested in pulsed conditions, Tj = 25 °C. Pulse width is 10 ms at rated test current. 2. Refer to Flux Characteristic Table for test current data. 3. Product is binned for color in x y coordinates. 4. Higher CRI options available upon request. 5. Center beam candle power is a calculated value based on lambertian radiation pattern at nominal test current. 6. Viewing angle is the off axis angle from t he centerline where Iv is ½ of the peak value.
Bridgelux RS Array Series Product Data Sheet DS16 (3/14/11) Page 8 of 32
Electrical Characteristics
Table 3: Electrical Characteristics Color Base Part Number [1] Forward Voltage Vf (V) [2] Test Current (mA) [3] Typical Temperature Coefficient of Forward Voltage (mV/°C) ΔVf/ΔTj Typical Thermal Resistance Junction to Case (°C/W) RѲ j-c Min Typ Max Warm White BXRA-W3500- XXXXX 21.9 24.6 27.1 2100 -8 to -24 0.2 BXRA-W5700- XXXXX 27.8 30.9 34.0 2800 -10 to -30 0.2 Neutral White BXRA-N4000- XXXXX 21.9 24.6 27.1 2100 -8 to -24 0.2 BXRA-N6300- XXXXX 27.8 30.9 34.0 2800 -10 to -30 0.2 Cool White BXRA-C5000- XXXXX 21.9 24.6 27.1 2100 -8 to -24 0.2 BXRA-C8000- XXXXX 27.8 30.9 34.0 2800 -10 to -30 0.2 Notes for Table 3: 1. XXXXX indicates specification applies to all versions with base number. 2. Parts are tested in pulsed conditions, Tj = 25°C. Pulse width is 10 ms at rated test current. 3. Bridgelux maintains a tester tolerance of ± 0.10 V on forward voltage measurements.
Bridgelux RS Array Series Product Data Sheet DS16 (3/14/11) Page 9 of 32 Absolute Minimum and Maximum Ratings Table 4: Minimum and Maximum Current and Reverse Voltage Ratings Part Number Maximum DC Forward Current (mA) Minimum DC Forward Current (mA) [2] Maximum Peak Pulsed Current (mA) [3] Maximum Reverse Voltage (Vr)[1] BXRA-W3500- XXXXX 3000 1200 4000 -40 Volts BXRA-W5700- XXXXX 3750 1500 5000 -50 Volts BXRA-N4000- XXXXX 3000 1200 4000 -40 Volts BXRA-N6300- XXXXX 3750 1500 5000 -50 Volts BXRA-C5000- XXXXX 3000 1200 4000 -40 Volts BXRA-C8000- XXXXX 3750 1500 5000 -50 Volts Notes for Table 4: 1. Light emitting diodes are not designed to be driven in reverse voltage. 2. Driving these high current devices at low currents can result in variations in performance. For low current operation pulse width modulation is recommended. 3. Bridgelux recommends a maximum duty cycle of 10% when operating LED Arrays at the maximum peak pulsed current specified. Table 5: Maximum Ratings Parameter Maximum Rating LED Junction Temperature 150°C Storage Temperature -40°C to +105°C Operating Case Temperature 105°C Soldering Temperature 3.5 seconds, 350°C or lower
Bridgelux RS Array Series Product Data Sheet DS16 (3/14/11) Page 10 of 32 Typical Performance at Alternative Drive Currents The Bridgelux LED Arrays are tested and binned against the specifications shown in Tables 1, 2 and 3. Customers also have options to drive the LED Arrays at alternative drive currents dependent on the specific application. The typical performance at any drive current can be derived from the flux vs. current characteristics shown in Figure 6 and from the current vs. voltage characteristics shown in Figure 10. The typical performance at common drive currents is also summarized in Table 6. Table 6: Typical Product Performance at Alternative Drive Currents Color CCT (K) Part Number Typical Luminous Flux фv (lm), Tcase=60°C Typical Luminous Flux фv (lm), Tj=25°C Typical Forward Voltage Vf (V) Forward Current (mA) [2] Warm White 2700K BXRA- W3500- 00S0E 2325 2575 23.7 1400 2750 3050 24.1 1750 3300 3700 24.6 2100 [1] 2700K BXRA- W3500- 00S0G 2075 2300 23.7 1400 2550 2825 24.1 1750 3000 3300 24.6 2100 [1] 3000K BXRA- W3500- 00Q0E 2525 2800 23.7 1400 3100 3425 24.1 1750 3600 4000 24.6 2100 [1] 3000K BXRA- W3500- 00Q0G 2275 2525 23.7 1400 2775 3075 24.1 1750 3250 3600 24.6 2100 [1] 2700K BXRA- W5700- 00S0E 3450 3825 29.6 1750 4050 4500 30.1 2100 5200 5800 30.9 2800 [1] 2700K BXRA- W5700- 00S0G 3100 3450 29.6 1750 3650 4050 30.1 2100 4700 5200 30.9 2800 [1] 3000K BXRA- W5700- 00Q0E 3725 4150 29.6 1750 4400 4900 30.1 2100 5700 6300 30.9 2800 [1] 3000K BXRA- W5700- 00Q0G 3375 3750 29.6 1750 4000 4400 30.1 2100 5100 5675 30.9 2800 [1] Notes for Table 6, 7 and 8: 1. Product is tested and binned at the specified drive current. 2. Operating these LED Arrays at or below the drive currents listed in Table 6, with a case temperature maintained at or below 70°C, will enable the average lumen maintenance projection outlined earlier in this Product Data Sheet.
Bridgelux RS Array Series Product Data Sheet DS16 (3/14/11) Page 11 of 32 Typical Performance at Alternative Drive Currents (continued) Table 7: Typical Product Performance at Alternative Drive Currents Color CCT (K) Part Number Typical Luminous Flux фv (lm), Tcase=60°C Typical Luminous Flux фv (lm), Tj=25°C Typical Forward Voltage Vf (V) Forward Current (mA) [2] Neutral White 4000K BXRA- N4000- 00L0E 2775 3075 23.7 1400 3375 3750 24.1 1750 4000 4400 24.6 2100 [1] 4000K BXRA- N6300- 00L0E 4150 4625 29.6 1750 4900 5450 30.1 2100 6300 7000 30.9 2800 [1] Table 8: Typical Product Performance at Alternative Drive Currents Color Color Part Number Typical Luminous Flux фv (lm), Tcase=60°C Typical Luminous Flux фv (lm), Tj=25°C Typical Forward Voltage Vf (V) Forward Current (mA) [2] Cool White 5600K BXRA- C5000- 00E0C 3525 3925 23.7 1400 4325 4800 24.1 1750 5100 5600 24.6 2100 [1] 5600K BXRA- C8000- 00E0C 5225 5800 29.6 1750 6175 6850 30.1 2100 7900 8800 30.9 2800 [1] Notes for Table 6, 7 and 8: 3. Product is tested and binned at the specified drive current. 4. Operating these LED Arrays at or below the drive currents listed in Table 6, with a case temperature maintained at or below 70°C, will enable the average lumen maintenance projection outlined earlier in this Product Data Sheet.
Bridgelux RS Array Series Product Data Sheet DS16 (3/14/11) Page 12 of 32 Mechanical Dimensions Notes for Figure 1: 1. Slots are for M2.5, M3 or #4 screws. 2. Solder pads are labeled “+” and “-“ to denote positive and negative, respectively. 3. It is not necessary to provide electrical connectio ns to both sets of solder pads. Either set of solder pads (6.35 x 2.03 mm rectangular pads or 3.50 mm tapered square pads) may be used depending on application specific design requirements. 4. Drawings are not to scale. 5. Drawing dimensions are in millimeters. 6. Bridgelux recommends four tapped holes for mounting screws – refer to figure 15 (Mechanical Assembly and Handling) for recommended spacing of holes. 7. Unless otherwise specified, tolerances are ± 0.10mm. 8. Dimensions with parenthesis ‘( )’ are for reference only. 9. Refer to product Application Notes AN10 and AN 11 for product handling, mounting and heat sink recommendations. 10. The optical center of the LED Array is defined by the mechanical center of the array. Figure 1: Drawing for all RS Array part numbers.
Bridgelux RS Array Series Product Data Sheet DS16 (3/14/11) Page 15 of 32 Wavelength Characteristics at Rated Test Current, Tj=25°C (Continued) Figure 6: Typical Cool White Color Spectrum
Bridgelux RS Array Series Product Data Sheet DS16 (3/14/11) Page 21 of 32 Product Binning Typical manufacturing processes of semiconductor products result in a variation in performance surrounding the typical data sheet values. In order to minimize variation in the end product or application, Bridgelux bins its LED Arrays for color. Bridgelux LED Arrays are labeled using a 3-digit alphanumeric bin code. This bin code is printed on the back of each LED Array in the following format: B C D Where: B C – designates color bin (P3, P4, Q3, etc.) D – designates color rendering index (0, A, B, C, etc) All product packaged within a single tube are of the same color bin combination (or bin code). Using these codes it is possible to determine the best product utilization to deliver the consistency required in a given application.
Bridgelux RS Array Series Product Data Sheet DS16 (3/14/11) Page 22 of 32 Color Binning Information Table 9: Warm White xy Bin Coordinates and Associated Typical CCT Bin Code X Y ANSI CCT (K) Bin Code X Y ANSI CCT (K) 0.4223 0.3990 0.4468 0.4077 2700 0.4299 0.4165 0.4562 0.4260 0.4431 0.4213 0.4688 0.4290 0.4345 0.4033 0.4585 0.4104 0.4147 0.3814 0.4373 0.3893 2700 0.4223 0.3990 0.4468 0.4077 0.4345 0.4033 0.4585 0.4104 0.4260 0.3854 0.4483 0.3919 0.4345 0.4033 0.4585 0.4104 2700 0.4431 0.4213 0.4688 0.4290 0.4562 0.4260 0.4813 0.4319 0.4468 0.4077 0.4703 0.4132 0.4260 0.3854 0.4483 0.3919 2700 0.4345 0.4033 0.4585 0.4104 0.4468 0.4077 0.4703 0.4132 0.4373 0.3893 0.4593 0.3944 0.4413 0.4107 0.4665 0.4175 0.4325 0.4075 0.4557 0.4145 0.4274 0.3958 0.4500 0.4026 0.4350 0.3984 0.4595 0.4050 3000 3000 3000 3000 3SDCM 3000 3SDCM 2700 Figure 16: Graph of Warm White Test Bins in xy Color Space
Bridgelux RS Array Series Product Data Sheet DS16 (3/14/11) Page 23 of 32 Color Binning Information (continued) 0.35 0.36 0.37 0.38 0.39 0.40 0.41 Y Z Table 10: Neutral White xy Bin Coordinates and Associated Typical CCT Bin Code X Y ANSI CCT (K) 0.3703 0.3726 0.3736 0.3874 0.3871 0.3959 0.3828 0.3803 0.3670 0.3578 0.3703 0.3726 0.3828 0.3803 0.3784 0.3647 0.3828 0.3803 0.3871 0.3959 0.4006 0.4044 0.3952 0.3880 0.3784 0.3647 0.3828 0.3803 0.3952 0.3880 0.3898 0.3716 0.3881 0.3879 0.3791 0.3823 0.3769 0.3724 0.3845 0.377 L3 4000 L4 4000 3SDCM 4000 M3 4000 M4 4000 Figure 17: Graph of Neutral White Test Bins in xy Color Space 4000K 3SDCM
Bridgelux RS Array Series Product Data Sheet DS16 (3/14/11) Page 24 of 32 Color Binning Information (continued) 0.31 0.32 0.33 0.34 0.35 0.36 0.37 Y X 5665 K 6020K 5310 K Table 11: Cool White xy Bin Coordinates and Associated Typical CCT Bin Code XY ANSI CCT (K) 0.3222 0.3243 0.3294 0.3306 0.3293 0.3423 0.3215 0.3353 0.3215 0.3353 0.3293 0.3423 0.3292 0.3539 0.3207 0.3462 0.3292 0.3539 0.3293 0.3423 0.3371 0.3493 0.3376 0.3616 0.3294 0.3306 0.3366 0.3369 0.3371 0.3493 0.3293 0.3423 5600 5600 5600 5600 Figure 18: Graph of Cool White Test Bins in xy Color Space
Bridgelux RS Array Series Product Data Sheet DS16 (3/14/11) Page 25 of 32 Mechanical Assembly and Handling Recommended assembly is illustrated below. When handling parts, please avoid contacting and do not apply stress to the resin area (see Figure 1, resin area is indicated in yellow). Product should be firmly secured onto appropriate heat sink by fastening M2.5, M3 or #4 screws on both sides of the product as illustrated in Figure 19. To ensure proper thermal contact it is important to mount the LED Array to the heat sink using 4 mounting screws. Bridgelux recommends the use of hard non- electrically conductive flat washers with lock washers. The recommended center to center spacing for the four tapped holes for mounting the Bridgelux RS Series Array is shown in Figure 20. Refer to Application Note AN11 – Handling and Assembly of Bridgelux LED Arrays, for more details. A thin layer of thermal grease should be applied to the bottom surface of the LED Array, between the bottom of the LED Array and the heat sink. All air gaps and voids between the heat sink and array should be eliminated. Ensure that sufficient thermal grease is used to cover the entire bottom surface of the array, but not so much that the thermal grease creeps up to the top of the array. Figure 19: Recommended Assembly Method Drawing Not to Scale
Bridgelux RS Array Series Product Data Sheet DS16 (3/14/11) Page 26 of 32 Mechanical Assembly and Handling (continued) Notes for Figure 20: 1. Drawing dimensions are in millimeters. Figure 20: Recommended Center to Center Spacing for Tapped Mounting Holes
Bridgelux RS Array Series Product Data Sheet DS16 (3/14/11) Page 27 of 32 Product Packaging and Labeling All Bridgelux LED Array products are 100% tested, binned and labeled. Products are labeled by printing pertinent information on the back side of the LED Array. The following format is used for labeling the Bridgelux LED Arrays: B C D B X R A – x x x x x E F G H J – W W Y Y Where: B C D – designates the bin code (Q30, etc.) x x x x x – designates the base part number (W3000, etc.) E F G H J or E F G H J K– designates the production lot code (12345, etc.). The Lot Code may be a five or six character number. W W Y Y – designates the date code (production week and production year, 0210, etc.) Individual Bridgelux LED Arrays are packaged in tubes for shipment. All product packaged within a single tube are of the same flux and color bin combination (or bin code). Each tube is labeled with the information required for effective inventory management. An example of the tube label is shown in Figure 21. Where: X X X X X – designates the base part number (W3000, etc.) B C D – designates the bin code (Q30, etc.) E F G H J or E F G H J K – designates the production lot code (12345, etc.). The lot code may be a five or six character number. W W Y Y – designates the date code (production week and production year, 0210, etc.) Z Z – designates the quantity (10 products per tube). Figure 21: Tube Label Example
Bridgelux RS Array Series Product Data Sheet DS16 (3/14/11) Page 29 of 32 Product Packaging and Labeling (continued) Where: X X X X X– designates the base part number (W3000, etc.) R R R R R – used to designate product options, 00000 by default. Q Q Q – designates the total quantity of LED Arrays contained in the box. E F G H J – designates product lot code. (The lot code may be a five or six character number.) B C D – designates the bin code (Q30, etc.) W W Y Y – designates the date code (production week and production year, 0210, etc.) Z Z Z – designates the quantity per listed bin code contained in the box. Figure 23: Box Label Example
Bridgelux RS Array Series Product Data Sheet DS16 (3/14/11) Page 30 of 32 Packaging Tube Design Notes for Figures 24: 1. Drawings are not to scale. 2. Drawing dimensions are in millimeters. Figure 24: Tube Design
Bridgelux RS Array Series Product Data Sheet DS16 (3/14/11) Page 31 of 32 Design Resources Bridgelux has developed a comprehensive set of application notes and design resources to assist customers in successfully designing with Bridgelux LED Array products. Included below is a list of available resources which can be downloaded from the Bridgelux web site under the Design Resources section. These documents are updated regularly as new information becomes available, including complimentary infrastructure products such as commercially available secondary optics and electronic driver solutions. Application Notes
- AN10: Effective Thermal Management of Bridgelux LED Arrays
- AN11: Assembly Considerations for Bridgelux LED Arrays
- AN12: Electrical Drive Considerations for Bridgelux LED Arrays
- AN14: Reliability Data Sheet for Bridgelux LED Arrays
- AN15: Reflow Soldering of Bridgelux LED Arrays
- AN16: Optical Considerations for Bridgelux LED Arrays Optical Source Models Optical source models and ray set files are available for all Bridgelux LED Array products, and can be downloaded directly from the Bridgelux web site. The list below contains the formats currently available. If you require a specific format not included in this list, please contact your Bridgelux sales representative for assistance.
- Zemax
- ASAP
- IESNA
- LightTools
- LucidShape
- OPTIS SPEOS
- PHOTOPIA
- TracePro
- Radiant Imaging Source Model 3D CAD Models Three dimensional CAD models depicting the product outline of all Bridgelux LED Arrays are available in both SAT and STEP formats. These CAD files can be downloaded directly from the Bridgelux web site.
Bridgelux RS Array Series Product Data Sheet DS16 (3/14/11) Page 32 of 32 About Bridgelux Bridgelux LED Arrays are developed, manufactured and marketed by Bridgelux, Inc. Bridgelux is a U.S. lighting company and leading developer of technologies and solutions that will transform the $40 billion global lighting industry into a $100 billion market opportunity. Based in Silicon Valley, Bridgelux is a pioneer in solid-state lighting (SSL), expanding the market for solid state lighting by driving down the cost of light through innovation. Bridgelux’s patented light source technology replaces traditional lighting technologies (such as incandescent, halogen and fluorescent lamps) with integrated, solid-state solutions, enabling lamp and luminaire manufacturers to develop high performance and energy-efficient white light products. The plug and play simplicity of the Bridgelux LED Arrays enable our customers to address the rapidly growing interior and exterior solid state lighting markets, including street lights, retail lighting, commercial lighting and consumer applications. With more than 450 patent applications filed or granted worldwide, Bridgelux is the only vertically integrated LED manufacturer that designs its solutions specifically for the lighting industry. For more information about the company, please visit www.bridgelux.com © 2011 Bridgelux, Inc. All rights reserved. Product specifications are subject to change without notice.