Vero® SE Series is a revolutionary light source system that integrates Bridgelux’s seventh generation COB technology with poke-in connectivity enabling solder-free installation. Vero SE LED light sources streamline assembly processes, lower manufacturing cost, simplify luminaire design, improve light quality and increase design flexibility. Vero SE is available in four different light emitting surface (LES) configurations that operate reliably over a broad current range. With Vero SE, secondary connector and holder components are not required, allowing for rapid integration of arrays into fixtures and an efficient field replaceable solution. Vero SE arrays deliver increased lumen density for improved beam control and precision lighting with 2 and 3 SDCM color control standards for clean and consistent uniform lighting. Bridgelux Décor Series is our state of the art color line designed specifically for premium applications, producing unmatched LED light quality with brilliant color-rendering options and offer pleasing and inspiring lighting palettes. Bridgelux Décor Series color points are available on Vero® SE Series, Vero® Series, V Series™ and V Series™ HD. Décor Series Class A is based on human response testing, providing color points with a combined GAI and CRI metric. Décor Series™ Ultra products provide a high CRI of 97 and a minimum R9 value of 93, which emphasizes the reds and color tones to which the human eye is most receptive - perfect for the most luxurious retail shops and world renowned museums. Décor Series Ultra is also a good replacement for halogen lamps. Décor Series™ Food products offer color points developed to address the unique requirements of the food, grocery, and restaurant industries. Highlighting the distinctive colors and nuanced patterns found in meats and breads, the Décor Series Food products are a must have for any butcher counter or bakery. Décor Series ™ Entertainment products provide color points developed specifically for the healthcare and entertainment industries. The 5600K cool white color point combined with a CRI of 90 or 97 provides the bright white required by these industries. Décor Series™ Street and Landmark is designed to be a direct replacement for high pressure sodium lamps. Décor Series™ Showcase is the optimal solution for replacing ceramic metal halide lamps, incorporating the same pure white light with enhanced spectrum coverage and higher efficacy. Vero SE

Features

  • Poke-in connectivity
  • Efficacy of 168 lm/W typical
  • Lumen output performance ranges from 1,372 to 13,060 lumens
  • Broad range of CCT options from 1750K to 6500K
  • CRI options: minimum 65, 70, 80, and 90
  • Color control: 2 and 3 SDCM for 2700K-4000K CCT
  • Reliable operation at up to 2X nominal drive current
  • Radial die pattern and improved lumen density
  • Top side part number markings
  • No exposed solder pads or electrical connections
  • V f bin code backside marking Benefits
  • Poke-in connectivity enables solderless, connector free installation
  • Broad application coverage for interior and exterior lighting
  • Flexibility for application driven lighting design requirements
  • High quality, true color reproduction
  • Uniform consistent white light
  • Flexibility in design optimization
  • Enhanced ease of use and assembly
  • Ability to configure multiple Vero SE arrays in series and parallel reduces customer driver cost
  • Improved inventory management and quality control

Vero SE 18 is the second largest form factor in the product family of next generation solid state light sources. In addition to delivering the performance and light quality required for many lighting applications, Product Nomenclature The part number designation for Bridgelux Vero SE LED arrays is explained as follows: 1 2 3 4 – 5 6 7 8 9 10 11 – 12 – 13 14 – 15 16 Product Family CCT Bin Options 2 = 2 SDCM 3 = 3 SDCM 4 = 4 SDCM CRI B = 65 CRI min. C = 70 CRI min. E = 80 CRI min. G = 90 CRI min. H = 97 CRI typ. A = Class A Array Configuration 17 = 1,750K 20 = 2,000K 25 = 2,500K 27 = 2,700K 30 = 3,000K 35 = 3,500K 40 = 4,000K 50 = 5,000K 56 = 5,600K 57 = 5,700K 65 = 6,500K BXRC – 30 E 400 0 – C – 7 3 – SE Color Targeting Designator 0 = Cold Targeted 1 = Hot Targeted C = Decor Series Showcase Target Gen. 7 Nominal CCT Flux Indicator 400x = 4000 lm Special Edition 2D Bar code provides full manufacturing traceability Polarity indication marks simplify manufacturing operator instructions Optic mounting holes Mounting holes Zhaga Book 3 compatible mounting locations Tc Measurement point Radial die configuration improves lumen density and beam control Top side part number marking improves inventory management and outgoing quality control Dual poke-in connectivity Wire release mechanisms x4 Test ports for probing Vero SE incorporates several features to simplify the design integration and manufacturing process, accelerate time to market and reduce system costs. Please visit www. bridgelux.com for more information on the Vero SE family of products.

The following product configurations are available: Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-17E4000-B-7x-SE 1750 80 900 2844 2560 34.8 31.3 91 BXRC-17E4000-C-7x-SE 1750 80 1170 3697 3327 34.8 40.7 91 BXRC-17E4000-D-7x-SE 1750 80 1050 2765 2488 29.0 30.5 91 BXRC-20B4001-C-7x-SE 2000 65 1170 6309 5678 34.8 40.7 155 BXRC-20B4001-D-7x-SE 2000 65 1050 4719 4247 29.0 30.5 155 BXRC-25E4000-B-7x-SE 2500 80 900 4730 4257 34.8 31.3 151 BXRC-25E4000-C-7x-SE 2500 80 1170 6149 5534 34.8 40.7 151 BXRC-25E4000-D-7x-SE 2500 80 1050 4598 4138 29.0 30.5 151 BXRC-27E4000-B-7x-SE 2700 80 900 4946 4451 34.8 31.3 158 BXRC-27E4000-C-7x-SE 2700 80 1170 6430 5787 34.8 40.7 158 BXRC-27E4000-D-7x-SE 2700 80 1050 4809 4328 29.0 30.5 158 BXRC-27G40H0-B-7x-SE 2700 90 900 4235 3812 34.8 31.3 135 BXRC-27G40H0-C-7x-SE 2700 90 1170 5506 4955 34.8 40.7 135 BXRC-27G40H0-D-7x-SE 2700 90 1050 4117 3706 29.0 30.5 135 BXRC-27G4000-B-7x-SE 2700 90 900 4080 3672 34.8 31.3 130 BXRC-27G4000-C-7x-SE 2700 90 1170 5305 4774 34.8 40.7 130 BXRC-27G4000-D-7x-SE 2700 90 1050 3967 3570 29.0 30.5 130 BXRC-27H4000-B-7x-SE 2700 97 900 3617 3255 34.8 31.3 115 BXRC-27H4000-C-7x-SE 2700 97 1170 4702 4232 34.8 40.7 115 BXRC-27H4000-D-7x-SE 2700 97 1050 3516 3165 29.0 30.5 115 BXRC-30C4001-B-7x-SE 3000 70 900 5502 4952 34.8 31.3 176 BXRC-30C4001-C-7x-SE 3000 70 1170 7153 6438 34.8 40.7 176 BXRC-30C4001-D-7x-SE 3000 70 1050 5350 4815 29.0 30.5 176 BXRC-30E4000-B-7x-SE 3000 80 900 5255 4730 34.8 31.3 168 BXRC-30E4000-C-7x-SE 3000 80 1170 6832 6149 34.8 40.7 168 BXRC-30E4000-D-7x-SE 3000 80 1050 5109 4598 29.0 30.5 168 BXRC-30G40H0-B-7x-SE 3000 90 900 4451 4006 34.8 31.3 142 BXRC-30G40H0-C-7x-SE 3000 90 1170 5787 5208 34.8 40.7 142 BXRC-30G40H0-D-7x-SE 3000 90 1050 4328 3895 29.0 30.5 142 BXRC-30G4000-B-7x-SE 3000 90 900 4266 3839 34.8 31.3 136 BXRC-30G4000-C-7x-SE 3000 90 1170 5546 4991 34.8 40.7 136 BXRC-30G4000-D-7x-SE 3000 90 1050 4147 3733 29.0 30.5 136 BXRC-30G400C-B-7x-SE 3000 90 900 4111 3700 34.8 31.3 131 BXRC-30G400C-D-7x-SE 3000 90 1050 3997 3597 29.0 30.5 131 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all oth- er products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance.

Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-30H4000-B-7x-SE 3000 97 900 3864 3478 34.8 31.3 123 BXRC-30H4000-C-7x-SE 3000 97 1170 5023 4521 34.8 40.7 123 BXRC-30H4000-D-7x-SE 3000 97 1050 3757 3381 29.0 30.5 123 BXRC-30A4001-B-7x-SE8,9 3000 93 900 3833 3450 34.8 31.3 122 BXRC-30A4001-C-7x-SE8,9 3000 93 1170 4983 4485 34.8 40.7 122 BXRC-30A4001-D-73-SE8,9 3000 93 1050 3727 3354 29.0 30.5 122 BXRC-35E4000-B-7x-SE 3500 80 900 5379 4841 34.8 31.3 172 BXRC-35E4000-C-7x-SE 3500 80 1170 6992 6293 34.8 40.7 172 BXRC-35E4000-D-7x-SE 3500 80 1050 5229 4706 29.0 30.5 172 BXRC-35G4000-B-7x-SE 3500 90 900 4421 3978 34.8 31.3 141 BXRC-35G4000-C-7x-SE 3500 90 1170 5747 5172 34.8 40.7 141 BXRC-35G4000-D-7x-SE 3500 90 1050 4298 3868 29.0 30.5 141 BXRC-35A4001-B-7x-SE8,9 3500 93 900 4080 3672 34.8 31.3 130 BXRC-35A4001-C-7x-SE8,9 3500 93 1170 5305 4774 34.8 40.7 130 BXRC-35A4001-D-7x-SE8,9 3500 93 1050 3967 3570 29.0 30.5 130 BXRC-40C4001-B-7x-SE 4000 90 900 5657 5091 34.8 31.3 181 BXRC-40C4001-C-7x-SE 4000 90 1170 7354 6619 34.8 40.7 181 BXRC-40C4001-D-7x-SE 4000 90 1050 5500 4950 29.0 30.5 181 BXRC-40E4000-B-7x-SE 4000 80 900 5410 4869 34.8 31.3 173 BXRC-40E4000-C-7x-SE 4000 80 1170 7033 6329 34.8 40.7 173 BXRC-40E4000-D-7x-SE 4000 80 1050 5259 4734 29.0 30.5 173 BXRC-40G4000-B-7x-SE 4000 90 900 4513 4062 34.8 31.3 144 BXRC-40G4000-C-7x-SE 4000 90 1170 5867 5281 34.8 40.7 144 BXRC-40G4000-D-7x-SE 4000 90 1050 4388 3949 29.0 30.5 144 BXRC-40H4000-B-7x-SE 4000 97 900 4080 3672 34.8 31.3 130 BXRC-40H4000-C-7x-SE 4000 97 1170 5305 4774 34.8 40.7 130 BXRC-40H4000-D-7x-SE 4000 97 1050 3967 3570 29.0 30.5 130 BXRC-40A4001-B-7x-SE8,9 4000 93 900 4421 3978 34.8 31.3 141 BXRC-40A4001-C-7x-SE8,9 4000 93 1170 5747 5172 34.8 40.7 141 BXRC-40A4001-D-7x-SE8,9 4000 93 1050 4298 3868 29.0 30.5 141 BXRC-50C4001-B-7x-SE 5000 70 900 5688 5119 34.8 31.3 182 BXRC-50C4001-C-7x-SE 5000 70 1170 7394 6655 34.8 40.7 182 BXRC-50C4001-D-7x-SE 5000 70 1050 5530 4977 29.0 30.5 182 BXRC-50E4001-B-7x-SE 5000 80 900 5472 4924 34.8 31.3 175 BXRC-50E4001-C-7x-SE 5000 80 1170 7113 6402 34.8 40.7 175 BXRC-50E4001-D-7x-SE 5000 80 1050 5320 4788 29.0 30.5 175 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance.

Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-50G4001-B-7x-SE 5000 90 900 4730 4257 34.8 31.3 151 BXRC-50G4001-C-7x-SE 5000 90 1170 6149 5534 34.8 40.7 151 BXRC-50G4001-D-7x-SE 5000 90 1050 4598 4138 29.0 30.5 151 BXRC-56G4000-B-7x-SE 5600 90 900 4761 4285 34.8 31.3 152 BXRC-56G4000-C-7x-SE 5600 90 1170 6189 5570 34.8 40.7 152 BXRC-56G400x-D-7x-SE 5600 90 1050 4628 4166 29.0 30.5 152 BXRC-56H4000-D-7x-SE 5600 97 1050 4178 3760 29.0 30.5 137 BXRC-57C4001-B-7x-SE 5700 70 900 5533 4980 34.8 31.3 177 BXRC-57C4001-C-7x-SE 5700 70 1170 7193 6474 34.8 40.7 177 BXRC-57C4001-D-7x-SE 5700 70 1050 5380 4842 29.0 30.5 177 BXRC-57E4001-B-7x-SE 5700 80 900 5255 4730 34.8 31.3 168 BXRC-57E4001-C-7x-SE 5700 80 1170 6832 6149 34.8 40.7 168 BXRC-57E4001-D-7x-SE 5700 80 1050 5109 4598 29.0 30.5 168 BXRC-65C4001-B-7x-SE 6500 70 900 5533 4980 34.8 31.3 177 BXRC-65C4001-C-7x-SE 6500 70 1170 7193 6474 34.8 40.7 177 BXRC-65C4001-D-7x-SE 6500 70 1050 5380 4842 29.0 30.5 177 BXRC-65E4001-B-7x-SE 6500 80 900 5317 4785 34.8 31.3 170 BXRC-65E4001-C-7x-SE 6500 80 1170 6912 6221 34.8 40.7 170 BXRC-65E4001-D-7x-SE 6500 80 1050 5169 4652 29.0 30.5 170 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance.

Table 2: Selection Guide, Stabilized DC Performance (Tc = 70°C) 7,8 Notes for Table 2: 1. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 2. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance. 3. CRI Values are specified as typical. 4. Drive current is referred to as nominal drive current. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 8. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at specified temperature. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 9. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. Part Number Nominal CCT1 (K) GAI2 CRI3 Nominal Drive Current4 (mA) Typical DC Flux5,6 Tc = 70ºC (lm) Minimum DC Flux6,9 Tc = 70ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-30A4001-B-7x-SE 3000 80 93 900 3565 3208 34.3 30.9 115 BXRC-30A4001-C-7x-SE 3000 80 93 1170 4634 4171 34.3 40.2 115 BXRC-30A4001-D-7x-SE 3000 80 93 1050 3466 3119 28.5 29.9 116 BXRC-35A4001-B-7x-SE 3500 80 93 900 3795 3415 34.3 30.9 123 BXRC-35A4001-C-7x-SE 3500 80 93 1170 4933 4440 34.3 40.2 123 BXRC-35A4001-D-7x-SE 3500 80 93 1050 3689 3321 28.5 29.9 123 BXRC-40A4001-B-7x-SE 4000 80 93 900 4111 3700 34.3 30.9 133 BXRC-40A4001-C-7x-SE 4000 80 93 1170 5344 4810 34.3 40.2 133 BXRC-40A4001-D-7x-SE 4000 80 93 1050 3997 3597 28.5 29.9 134

Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-17E4000-B-7x-SE 1750 80 900 2560 2304 33.9 30.5 84 BXRC-17E4000-C-7x-SE 1750 80 1170 3327 2995 33.9 39.7 84 BXRC-17E4000-D-7x-SE 1750 80 1050 2488 2240 28.3 29.7 84 BXRC-20B4001-C-7x-SE 2000 65 1170 5678 5111 34.1 39.9 142 BXRC-20B4001-D-7x-SE 2000 65 1050 4247 3822 28.3 29.7 143 BXRC-25E4000-B-7x-SE 2500 80 900 4257 3831 33.9 30.5 139 BXRC-25E4000-C-7x-SE 2500 80 1170 5534 4980 33.9 39.7 139 BXRC-25E4000-D-7x-SE 2500 80 1050 4138 3725 28.3 29.7 139 BXRC-27E4000-B-7x-SE 2700 80 900 4451 4006 33.9 30.5 146 BXRC-27E4000-C-7x-SE 2700 80 1170 5787 5208 33.9 39.7 146 BXRC-27E4000-D-7x-SE 2700 80 1050 4328 3895 28.3 29.7 146 BXRC-27G40H0-B-7x-SE 2700 90 900 3812 3430 33.9 30.5 125 BXRC-27G40H0-C-7x-SE 2700 90 1170 4955 4460 33.9 39.7 125 BXRC-27G40H0-D-7x-SE 2700 90 1050 3706 3335 28.3 29.7 125 BXRC-27G4000-B-7x-SE 2700 90 900 3672 3305 33.9 30.5 120 BXRC-27G4000-C-7x-SE 2700 90 1170 4774 4297 33.9 39.7 120 BXRC-27G4000-D-7x-SE 2700 90 1050 3570 3213 28.3 29.7 120 BXRC-27H4000-B-7x-SE 2700 97 900 3255 2930 33.9 30.5 107 BXRC-27H4000-C-7x-SE 2700 97 1170 4232 3808 33.9 39.7 107 BXRC-27H4000-D-7x-SE 2700 97 1050 3165 2848 28.3 29.7 107 BXRC-30C4001-B-7x-SE 3000 70 900 4952 4457 33.9 30.5 162 BXRC-30C4001-C-7x-SE 3000 70 1170 6438 5794 33.9 39.7 162 BXRC-30C4001-D-7x-SE 3000 70 1050 4815 4333 28.3 29.7 162 BXRC-30E4000-B-7x-SE 3000 80 900 4730 4257 33.9 30.5 155 BXRC-30E4000-C-7x-SE 3000 80 1170 6149 5534 33.9 39.7 155 BXRC-30E4000-D-7x-SE 3000 80 1050 4598 4138 28.3 29.7 155 BXRC-30G40H0-B-7x-SE 3000 90 900 4006 3606 33.9 30.5 131 BXRC-30G40H0-C-7x-SE 3000 90 1170 5208 4687 33.9 39.7 131 BXRC-30G40H0-D-7x-SE 3000 90 1050 3895 3506 28.3 29.7 131 BXRC-30G4000-B-7x-SE 3000 90 900 3839 3455 33.9 30.5 126 BXRC-30G4000-C-7x-SE 3000 90 1170 4991 4492 33.9 39.7 126 BXRC-30G4000-D-7x-SE 3000 90 1050 3733 3359 28.3 29.7 126 BXRC-30G400C-B-7x-SE 3000 90 900 3700 3330 33.9 30.5 121 BXRC-30G400C-D-7x-SE 3000 90 1050 3597 3238 28.3 29.7 121 BXRC-30H4000-B-7x-SE 3000 97 900 3478 3130 33.9 30.5 114 Notes for Table 3: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance.

Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-30H4000-C-7x-SE 3000 97 1170 4521 4069 33.9 39.7 114 BXRC-30H4000-D-7x-SE 3000 97 1050 3381 3043 28.3 29.7 114 BXRC-30A4001-B-7x-SE7,8 3000 93 900 3450 3105 33.9 30.5 113 BXRC-30A4001-C-7x-SE7,8 3000 93 1170 4485 4036 33.9 39.7 113 BXRC-30A4001-D-7x-SE7,8 3000 93 1050 3354 3019 28.3 29.7 113 BXRC-35E4000-B-7x-SE 3500 80 900 4841 4357 33.9 30.5 159 BXRC-35E4000-C-7x-SE 3500 80 1170 6293 5664 33.9 39.7 159 BXRC-35E4000-D-7x-SE 3500 80 1050 4706 4236 28.3 29.7 159 BXRC-35G4000-B-7x-SE 3500 90 900 3978 3581 33.9 30.5 130 BXRC-35G4000-C-7x-SE 3500 90 1170 5172 4655 33.9 39.7 130 BXRC-35G4000-D-7x-SE 3500 90 1050 3868 3481 28.3 29.7 130 BXRC-35A4001-B-7x-SE7,8 3500 93 900 3672 3305 33.9 30.5 120 BXRC-35A4001-C-7x-SE7,8 3500 93 1170 4774 4297 33.9 39.7 120 BXRC-35A4001-D-7x-SE7,8 3500 93 1050 3570 3213 28.3 29.7 120 BXRC-40C4001-B-7x-SE 4000 70 900 5091 4582 33.9 30.5 167 BXRC-40C4001-C-7x-SE 4000 70 1170 6619 5957 33.9 39.7 167 BXRC-40C4001-D-7x-SE 4000 70 1050 4950 4455 28.3 29.7 167 BXRC-40E4000-B-7x-SE 4000 80 900 4869 4382 33.9 30.5 160 BXRC-40E4000-C-7x-SE 4000 80 1170 6329 5696 33.9 39.7 160 BXRC-40E4000-D-7x-SE 4000 80 1050 4734 4260 28.3 29.7 159 BXRC-40G4000-B-7x-SE 4000 90 900 4062 3656 33.9 30.5 133 BXRC-40G4000-C-7x-SE 4000 90 1170 5281 4752 33.9 39.7 133 BXRC-40G4000-D-7x-SE 4000 90 1050 3949 3554 28.3 29.7 133 BXRC-40H4000-B-7x-SE 4000 97 900 3672 3305 33.9 30.5 120 BXRC-40H4000-C-7x-SE 4000 97 1170 4774 4297 33.9 39.7 120 BXRC-40H4000-D-7x-SE 4000 97 1050 3570 3213 28.3 29.7 120 BXRC-40A4001-B-7x-SE7,8 4000 93 900 3978 3581 34.1 30.7 130 BXRC-40A4001-C-7x-SE7,8 4000 93 1170 5172 4655 34.1 39.9 130 BXRC-40A4001-D-7x-SE7,8 4000 93 1050 3868 3481 28.3 29.7 130 BXRC-50C4001-B-7x-SE 5000 70 900 5119 4607 34.1 30.7 167 BXRC-50C4001-C-7x-SE 5000 70 1170 6655 5989 34.1 39.9 167 BXRC-50C4001-D-7x-SE 5000 70 1050 4977 4479 28.3 29.7 168 BXRC-50E4001-B-7x-SE 5000 80 900 4924 4432 34.1 30.7 161 BXRC-50E4001-C-7x-SE 5000 80 1170 6402 5762 34.1 39.9 161 BXRC-50E4001-D-7x-SE 5000 80 1050 4788 4309 28.3 29.7 161 Notes for Table 3: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance.

(K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-50G4001-B-7x-SE 5000 90 900 4257 3831 34.1 30.7 139 BXRC-50G4001-C-7x-SE 5000 90 1170 5534 4980 34.1 39.9 139 BXRC-50G4001-D-7x-SE 5000 90 1050 4138 3725 28.3 29.7 139 BXRC-56G4000-B-7x-SE 5600 90 900 4285 3856 34.1 30.7 140 BXRC-56G4000-C-7x-SE 5600 90 1170 5570 5013 34.1 39.9 140 BXRC-56G400x-D-7x-SE 5600 90 1050 4166 3749 28.3 29.7 140 BXRC-56H4000-D-7x-SE 5600 97 1050 3760 3384 28.3 29.7 127 BXRC-57C4001-B-7x-SE 5700 80 900 4980 4482 34.1 30.7 162 BXRC-57C4001-C-7x-SE 5700 80 1170 6474 5827 34.1 39.9 162 BXRC-57C4001-D-7x-SE 5700 80 1050 4842 4358 28.3 29.7 163 BXRC-57E4001-B-7x-SE 5700 80 900 4730 4257 34.1 30.7 154 BXRC-57E4001-C-7x-SE 5700 80 1170 6149 5534 34.1 39.9 154 BXRC-57E4001-D-7x-SE 5700 80 1050 4598 4138 28.3 29.7 155 BXRC-65C4001-B-7x-SE 6500 70 900 4980 4482 34.1 30.7 162 BXRC-65C4001-C-7x-SE 6500 70 1170 6474 5827 34.1 39.9 162 BXRC-65C4001-D-7x-SE 6500 70 1050 4842 4358 28.3 29.7 163 BXRC-65E4001-B-7x-SE 6500 80 900 4785 4307 34.1 30.7 156 BXRC-65E4001-C-7x-SE 6500 80 1170 6221 5599 34.1 39.9 156 BXRC-65E4001-D-7x-SE 6500 80 1050 4652 4187 28.3 29.7 157 Notes for Table 3: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 98. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance. Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 (continued)

European Product Registry for Energy Labeling The European Product Registry for Energy Labeling (EPREL) is defined in the EU Regulation 2017/1369 to provide import- ant energy efficiency information to consumers. Together with Energy Labeling Regulation ELR (EU) 2019/2015 which was amended by regulation (EU) 2021/340 for energy labelling of light sources, manufacturers are required to declare an ener- gy class based on key technical specifications from each of their product and register it in an open data base managed by EPREL It is now a legal requirement for a vendor of light sources to upload information about their products into the EPREL database before placing these products on the market in the EU. Table 4 below provides a list of part numbers that are in compliance with ELR and are currently listed in the EPREL data- base. At Bridgelux, we are fully committed to supplying products that are compliant with pertinent laws, rules, and obligation imposed by relevant government bodies including the European Energy Labeling regulation. Customers can use these products with full confidence for any projects that fall under the ELR. Table 4: Part numbers registered in European Product Registry for Energy Labeling PART NUMBER1 CCT (K) CRI Current2 (mA) Vf (V) Useful flux3 (Φuse) at 85C (lm) Pow- er (W) Efficacy (lm/W) Energy efficiency class4 Regis- tration No URL to Product Information Sheet in EPREL Database Notes for Table 4: 1. All device listed here must be disposed as e-waste upon its end of life according to local country guideline in each country. 2. For information on performance values at alternative drive conditions. please refer to the Product Selection Guide, Absolute Maximum Rating Table and Performance Curves in this data sheet. 3. For a definition of useful luminous flux (ΦΦuse), please see the ELR regulations at https:/ /tinyurl.com/4b6zvt4m. 4. EPREL requires an arrow symbol containing the letter of the energy efficiency class to be displayed. on technical promotional material. Refer to this energy efficiency class column for specific energy efficiency class on each part number.

European Product Registry for Energy Labeling Table 4: Part numbers registered in European Product Registry for Energy Labeling (Continued) PART NUMBER1 CCT (K) CRI Current2 (mA) Vf (V) Useful flux3 (Φuse) at 85C (lm) Pow- er (W) Efficacy (lm/W) Energy efficiency class4 Regis- tration No URL to Product Information Sheet in EPREL Database Notes for Table 4: 1. All device listed here must be disposed as e-waste upon its end of life according to local country guideline in each country. 2. For information on performance values at alternative drive conditions. please refer to the Product Selection Guide, Absolute Maximum Rating Table and Performance Curves in this data sheet. 3. For a definition of useful luminous flux (ΦΦuse), please see the ELR regulations at https:/ /tinyurl.com/4b6zvt4m. 4. EPREL requires an arrow symbol containing the letter of the energy efficiency class to be displayed. on technical promotional material. Refer to this energy efficiency class column for specific energy efficiency class on each part number.

European Product Registry for Energy Labeling Table 4: Part numbers registered in European Product Registry for Energy Labeling (Continued) PART NUMBER1 CCT (K) CRI Current2 (mA) Vf (V) Useful flux3 (Φuse) at 85C (lm) Pow- er (W) Efficacy (lm/W) Energy efficiency class4 Regis- tration No URL to Product Information Sheet in EPREL Database Notes for Table 4: 1. All device listed here must be disposed as e-waste upon its end of life according to local country guideline in each country. 2. For information on performance values at alternative drive conditions. please refer to the Product Selection Guide, Absolute Maximum Rating Table and Performance Curves in this data sheet. 3. For a definition of useful luminous flux (ΦΦuse), please see the ELR regulations at https:/ /tinyurl.com/4b6zvt4m. 4. EPREL requires an arrow symbol containing the letter of the energy efficiency class to be displayed. on technical promotional material. Refer to this energy efficiency class column for specific energy efficiency class on each part number.

Performance at Commonly Used Drive Currents Table 5: Product Performance at Commonly Used Drive Currents Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-17E4000-B-7x-SE 80 450 33.1 14.9 1469 1342 98 600 33.8 20.3 1929 1754 95 900 34.8 31.3 2844 2560 91 1350 36.5 49.2 4103 3615 83 1800 37.8 68.1 5173 4445 76 BXRC-17E4000-C-7x-SE 80 585 33.2 19.4 1910 1745 98 780 33.8 26.4 2508 2280 95 1170 34.8 40.7 3697 3327 91 1755 36.5 64.1 5334 4699 83 2340 37.9 88.8 6725 5778 76 BXRC-17E4000-D-7x-SE 80 525 27.7 14.6 1431 1307 98 700 28.2 19.8 1868 1698 95 1050 29.0 30.5 2765 2488 91 1575 30.4 47.9 4088 3601 85 2100 31.5 66.2 5265 4524 80 BXRC-20B4001-C-7x-SE 65 585 33.2 19.4 3259 2977 168 780 33.8 26.4 4280 3891 162 1170 34.8 40.7 6309 5678 155 1755 36.5 64.1 9103 8019 142 2340 37.9 88.8 11477 9861 129 BXRC-20B4001-D-7x-SE 65 525 27.7 14.6 2442 2231 168 700 28.2 19.8 3188 2898 161 1050 29.0 30.5 4719 4247 155 1575 30.4 47.9 6975 6145 146 2100 31.5 66.2 8985 7720 136 BXRC-25E4000-B-7x-SE 80 450 33.1 14.9 2443 2232 164 600 33.8 20.3 3208 2917 158 900 34.8 31.3 4730 4257 151 1350 36.5 49.2 6824 6011 139 1800 37.8 68.1 8603 7392 126 BXRC-25E4000-C-7x-SE 80 585 33.2 19.4 3176 2901 164 780 33.8 26.4 4171 3792 158 1170 34.8 40.7 6149 5534 151 1755 36.5 64.1 8871 7814 138 2340 37.9 88.8 11184 9610 126 BXRC-25E4000-D-7x-SE 80 525 27.7 14.6 2380 2174 163 700 28.2 19.8 3107 2824 157 1050 29.0 30.5 4598 4138 151 1575 30.4 47.9 6798 5988 142 2100 31.5 66.2 8756 7524 132 Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. Vero LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. Vero SE may also be driven at other drive currents dependent on specific application design requirements. The performance at any drive current can be derived from the current vs. voltage characteristics shown in Figures 1, 2 & 3 and the flux vs. current characteristics shown in Figures 4, 5 & 6. The performance at commonly used drive currents is summarized in Table 5.

Performance at Commonly Used Drive Currents Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-27E4000-B-7x-SE 80 450 33.1 14.9 2555 2334 171 600 33.8 20.3 3355 3050 166 900 34.8 31.3 4946 4451 158 1350 36.5 49.2 7136 6286 145 1800 37.8 68.1 8997 7730 132 BXRC-27E4000-C-7x-SE 80 585 33.2 19.4 3321 3034 171 780 33.8 26.4 4361 3965 165 1170 34.8 40.7 6430 5787 158 1755 36.5 64.1 9276 8172 145 2340 37.9 88.8 11696 10050 132 BXRC-27E4000-D-7x-SE 80 525 27.7 14.6 2488 2274 171 700 28.2 19.8 3249 2954 164 1050 29.0 30.5 4809 4328 158 1575 30.4 47.9 7109 6262 148 2100 31.5 66.2 9157 7868 138 BXRC-27G40H0-B-7x-SE 90 450 33.1 14.9 2187 1998 147 600 33.8 20.3 2873 2612 142 900 34.8 31.3 4235 3812 135 1350 36.5 49.2 6110 5382 124 1800 37.8 68.1 7704 6619 113 BXRC-27G40H0-C-7x-SE 90 585 33.2 19.4 2844 2598 147 780 33.8 26.4 3734 3395 142 1170 34.8 40.7 5506 4955 135 1755 36.5 64.1 7943 6997 124 2340 37.9 88.8 10015 8605 113 BXRC-27G40H0-D-7x-SE 90 525 27.7 14.6 2131 1947 146 700 28.2 19.8 2782 2529 141 1050 29.0 30.5 4117 3706 135 1575 30.4 47.9 6087 5362 127 2100 31.5 66.2 7841 6737 118 BXRC-27G4000-B-7x-SE 90 450 33.1 14.9 2108 1926 141 600 33.8 20.3 2768 2516 137 900 34.8 31.3 4080 3672 130 1350 36.5 49.2 5887 5186 120 1800 37.8 68.1 7423 6378 109 BXRC-27G4000-C-7x-SE 90 585 33.2 19.4 2740 2503 141 780 33.8 26.4 3598 3271 136 1170 34.8 40.7 5305 4774 130 1755 36.5 64.1 7653 6742 119 2340 37.9 88.8 9649 8291 109 BXRC-27G4000-D-7x-SE 90 525 27.7 14.6 2053 1876 141 700 28.2 19.8 2680 2437 136 1050 29.0 30.5 3967 3570 130 1575 30.4 47.9 5865 5166 122 2100 31.5 66.2 7554 6491 114

Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-27H4000-B-7x-SE 80 450 33.1 14.9 1868 1707 125 600 33.8 20.3 2453 2230 121 900 34.8 31.3 3617 3255 115 1350 36.5 49.2 5218 4597 106 1800 37.8 68.1 6579 5653 97 BXRC-27H4000-C-7x-SE 80 585 33.2 19.4 2429 2219 125 780 33.8 26.4 3189 2900 121 1170 34.8 40.7 4702 4232 115 1755 36.5 64.1 6783 5976 106 2340 37.9 88.8 8553 7349 96 BXRC-27H4000-D-7x-SE 80 525 27.7 14.6 1820 1663 125 700 28.2 19.8 2376 2160 120 1050 29.0 30.5 3516 3165 115 1575 30.4 47.9 5198 4579 108 2100 31.5 66.2 6696 5753 101 BXRC-30C4001-B-74-SE 70 450 33.1 14.9 2842 2597 191 600 33.8 20.3 3732 3393 184 900 34.8 31.3 5502 4952 176 1350 36.5 49.2 7939 6993 161 1800 37.8 68.1 10009 8600 147 BXRC-30C4001-C-74-SE 70 585 33.2 19.4 3695 3375 190 780 33.8 26.4 4852 4411 184 1170 34.8 40.7 7153 6438 176 1755 36.5 64.1 10320 9091 161 2340 37.9 88.8 13012 11180 147 BXRC-30C4001-D-74-SE 70 525 27.7 14.6 2768 2529 190 700 28.2 19.8 3614 3286 183 1050 29.0 30.5 5350 4815 176 1575 30.4 47.9 7908 6967 165 2100 31.5 66.2 10187 8753 154 BXRC-30E4000-B-7x-SE 80 450 33.1 14.9 2714 2480 182 600 33.8 20.3 3565 3241 176 900 34.8 31.3 5255 4730 168 1350 36.5 49.2 7582 6679 154 1800 37.8 68.1 9559 8214 140 BXRC-30E4000-C-7x-SE 80 585 33.2 19.4 3529 3224 182 780 33.8 26.4 4634 4213 176 1170 34.8 40.7 6832 6149 168 1755 36.5 64.1 9856 8683 154 2340 37.9 88.8 12427 10678 140 BXRC-30E4000-D-7x-SE 80 525 27.7 14.6 2644 2416 182 700 28.2 19.8 3452 3138 175 1050 29.0 30.5 5109 4598 168 1575 30.4 47.9 7553 6654 158 2100 31.5 66.2 9729 8359 147 Performance at Commonly Used Drive Currents

Performance at Commonly Used Drive Currents Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-30G40H0-B-7x-SE 90 450 33.1 14.9 2299 2101 154 600 33.8 20.3 3019 2745 149 900 34.8 31.3 4451 4006 142 1350 36.5 49.2 6422 5657 130 1800 37.8 68.1 8097 6957 119 BXRC-30G40H0-C-7x-SE 90 585 33.2 19.4 2989 2731 154 780 33.8 26.4 3925 3569 149 1170 34.8 40.7 5787 5208 142 1755 36.5 64.1 8349 7355 130 2340 37.9 88.8 10527 9045 119 BXRC-30G40H0-D-7x-SE 90 525 27.7 14.6 2240 2046 154 700 28.2 19.8 2924 2658 148 1050 29.0 30.5 4328 3895 142 1575 30.4 47.9 6398 5636 133 2100 31.5 66.2 8241 7081 124 BXRC-30G4000-B-7x-SE 90 450 33.1 14.9 2203 2013 148 600 33.8 20.3 2894 2631 143 900 34.8 31.3 4266 3839 136 1350 36.5 49.2 6155 5422 125 1800 37.8 68.1 7760 6667 114 BXRC-30G4000-C-7x-SE 90 585 33.2 19.4 2864 2617 148 780 33.8 26.4 3762 3420 143 1170 34.8 40.7 5546 4991 136 1755 36.5 64.1 8001 7048 125 2340 37.9 88.8 10088 8668 114 BXRC-30G4000-D-7x-SE 90 525 27.7 14.6 2146 1961 147 700 28.2 19.8 2802 2548 142 1050 29.0 30.5 4147 3733 136 1575 30.4 47.9 6131 5401 128 2100 31.5 66.2 7898 6786 119 BXRC-30G400C-B-7x-SE 90 450 33.1 14.9 2124 1940 142 600 33.8 20.3 2789 2535 138 900 34.8 31.3 4111 3700 131 1350 36.5 49.2 5932 5225 121 1800 37.8 68.1 7479 6426 110 BXRC-30G400C-D-7x-SE 90 525 27.7 14.6 2065 1886 142 700 28.2 19.8 2711 2465 137 1050 29.0 30.5 3997 3597 131 1575 30.4 47.9 5767 5080 120 2100 31.5 66.2 7271 6247 110 BXRC-30H4000-B-7x-SE 80 450 33.1 14.9 1996 1823 134 600 33.8 20.3 2621 2383 129 900 34.8 31.3 3864 3478 123 1350 36.5 49.2 5575 4911 113 1800 37.8 68.1 7029 6039 103

Performance at Commonly Used Drive Currents Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-30H4000-C-7x-SE 80 585 33.2 19.4 2595 2370 134 780 33.8 26.4 3407 3098 129 1170 34.8 40.7 5023 4521 123 1755 36.5 64.1 7247 6384 113 2340 37.9 88.8 9138 7851 103 BXRC-30H4000-D-7x-SE 80 525 27.7 14.6 1944 1776 134 700 28.2 19.8 2538 2308 128 1050 29.0 30.5 3757 3381 123 1575 30.4 47.9 5554 4892 116 2100 31.5 66.2 7154 6147 108 BXRC-30A4001-B-7x-SE 93 450 33.1 14.9 1980 1809 133 600 33.8 20.3 2600 2364 128 900 34.8 31.3 3833 3450 122 1350 36.5 49.2 5530 4872 112 1800 37.8 68.1 6973 5991 102 BXRC-30A4001-C-7x-SE 93 585 33.2 19.4 2574 2351 133 780 33.8 26.4 3380 3073 128 1170 34.8 40.7 4983 4485 122 1755 36.5 64.1 7189 6333 112 2340 37.9 88.8 9065 7788 102 BXRC-30A4001-D-7x-SE 93 525 27.7 14.6 1929 1762 132 700 28.2 19.8 2518 2289 127 1050 29.0 30.5 3727 3354 122 1575 30.4 47.9 5509 4853 115 2100 31.5 66.2 7097 6097 107 BXRC-35E4000-B-7x-SE 80 450 33.1 14.9 2778 2538 186 600 33.8 20.3 3649 3317 180 900 34.8 31.3 5379 4841 172 1350 36.5 49.2 7760 6836 158 1800 37.8 68.1 9784 8407 144 BXRC-35E4000-C-7x-SE 80 585 33.2 19.4 3612 3300 186 780 33.8 26.4 4743 4312 180 1170 34.8 40.7 6992 6293 172 1755 36.5 64.1 10088 8887 157 2340 37.9 88.8 12720 10929 143 BXRC-35E4000-D-7x-SE 80 525 27.7 14.6 2706 2472 186 700 28.2 19.8 3533 3212 179 1050 29.0 30.5 5229 4706 172 1575 30.4 47.9 7731 6810 161 2100 31.5 66.2 9958 8556 150 BXRC-35G4000-B-7x-SE 90 450 33.1 14.9 2283 2086 153 600 33.8 20.3 2998 2726 148 900 34.8 31.3 4421 3978 141 1350 36.5 49.2 6378 5618 130 1800 37.8 68.1 8041 6909 118

Performance at Commonly Used Drive Currents Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-35G4000-C-7x-SE 90 585 33.2 19.4 2968 2712 153 780 33.8 26.4 3898 3544 148 1170 34.8 40.7 5747 5172 141 1755 36.5 64.1 8291 7304 129 2340 37.9 88.8 10453 8982 118 BXRC-35G4000-D-7x-SE 90 525 27.7 14.6 2224 2032 153 700 28.2 19.8 2904 2640 147 1050 29.0 30.5 4298 3868 141 1575 30.4 47.9 6353 5597 133 2100 31.5 66.2 8184 7032 124 BXRC-35A4001-B-7x-SE 93 450 33.1 14.9 2108 1926 141 600 33.8 20.3 2768 2516 137 900 34.8 31.3 4080 3672 130 1350 36.5 49.2 5887 5186 120 1800 37.8 68.1 7423 6378 109 BXRC-35A4001-C-7x-SE 93 585 33.2 19.4 2740 2503 141 780 33.8 26.4 3598 3271 136 1170 34.8 40.7 5305 4774 130 1755 36.5 64.1 7653 6742 119 2340 37.9 88.8 9649 8291 109 BXRC-35A4001-D-7x-SE 93 525 27.7 14.6 2053 1876 141 700 28.2 19.8 2680 2437 136 1050 29.0 30.5 3967 3570 130 1575 30.4 47.9 5865 5166 122 2100 31.5 66.2 7554 6491 114 BXRC-40C4001-B-7x-SE 70 450 33.1 14.9 2922 2669 196 600 33.8 20.3 3837 3489 189 900 34.8 31.3 5657 5091 181 1350 36.5 49.2 8161 7190 166 1800 37.8 68.1 10290 8842 151 BXRC-40C4001-C-7x-SE 70 585 33.2 19.4 3798 3470 196 780 33.8 26.4 4988 4535 189 1170 34.8 40.7 7354 6619 181 1755 36.5 64.1 10610 9347 165 2340 37.9 88.8 13377 11494 151 BXRC-40C4001-D-7x-SE 70 525 27.7 14.6 2846 2600 195 700 28.2 19.8 3716 3378 188 1050 29.0 30.5 5500 4950 181 1575 30.4 47.9 8131 7163 170 2100 31.5 66.2 10473 8999 158 BXRC-40E4000-B-7x-SE 80 450 33.1 14.9 2794 2553 187 600 33.8 20.3 3669 3336 181 900 34.8 31.3 5410 4869 173 1350 36.5 49.2 7805 6875 159 1800 37.8 68.1 9841 8455 145

Performance at Commonly Used Drive Currents Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-40E4000-C-7x-SE 80 585 33.2 19.4 3632 3319 187 780 33.8 26.4 4770 4337 181 1170 34.8 40.7 7033 6329 173 1755 36.5 64.1 10146 8938 158 2340 37.9 88.8 12793 10992 144 BXRC-40E4000-D-7x-SE 80 525 27.7 14.6 2722 2487 187 700 28.2 19.8 3553 3231 180 1050 29.0 30.5 5259 4734 173 1575 30.4 47.9 7775 6849 162 2100 31.5 66.2 10015 8605 151 BXRC-40G4000-B-7x-SE 90 450 33.1 14.9 2331 2130 156 600 33.8 20.3 3061 2783 151 900 34.8 31.3 4513 4062 144 1350 36.5 49.2 6511 5736 132 1800 37.8 68.1 8210 7054 121 BXRC-40G4000-C-7x-SE 90 585 33.2 19.4 3030 2769 156 780 33.8 26.4 3980 3618 151 1170 34.8 40.7 5867 5281 144 1755 36.5 64.1 8465 7457 132 2340 37.9 88.8 10673 9170 120 BXRC-40G4000-D-7x-SE 90 525 27.7 14.6 2271 2075 156 700 28.2 19.8 2965 2695 150 1050 29.0 30.5 4388 3949 144 1575 30.4 47.9 6487 5714 135 2100 31.5 66.2 8356 7179 126 BXRC-40H4000-B-7x-SE 97 450 33.1 14.9 2108 1926 141 600 33.8 20.3 2768 2516 137 900 34.8 31.3 4080 3672 130 1350 36.5 49.2 5887 5186 120 1800 37.8 68.1 7423 6378 109 BXRC-40H4000-C-7x-SE 97 585 33.2 19.4 2740 2503 141 780 33.8 26.4 3598 3271 136 1170 34.8 40.7 5305 4774 130 1755 36.5 64.1 7653 6742 119 2340 37.9 88.8 9649 8291 109 BXRC-40H4000-D-7x-SE 97 525 27.7 14.6 2053 1876 141 700 28.2 19.8 2680 2437 136 1050 29.0 30.5 3967 3570 130 1575 30.4 47.9 5865 5166 122 2100 31.5 66.2 7554 6491 114 BXRC-40A4001-B-7x-SE 93 450 33.1 14.9 2283 2086 153 600 33.8 20.3 2998 2726 148 900 34.8 31.3 4421 3978 141 1350 36.5 49.2 6378 5618 130 1800 37.8 68.1 8041 6909 118

Performance at Commonly Used Drive Currents Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-40A4001-C-7x-SE 93 585 33.2 19.4 2968 2712 153 780 33.8 26.4 3898 3544 148 1170 34.8 40.7 5747 5172 141 1755 36.5 64.1 8291 7304 129 2340 37.9 88.8 10453 8982 118 BXRC-40A4001-D-7x-SE 93 525 27.7 14.6 2224 2032 153 700 28.2 19.8 2904 2640 147 1050 29.0 30.5 4298 3868 141 1575 30.4 47.9 6353 5597 133 2100 31.5 66.2 8184 7032 124 BXRC-50C4001-B-7x-SE 70 450 33.1 14.9 2938 2684 197 600 33.8 20.3 3858 3508 191 900 34.8 31.3 5688 5119 182 1350 36.5 49.2 8206 7229 167 1800 37.8 68.1 10347 8890 152 BXRC-50C4001-C-7x-SE 70 585 33.2 19.4 3819 3489 197 780 33.8 26.4 5016 4560 190 1170 34.8 40.7 7394 6655 182 1755 36.5 64.1 10668 9398 166 2340 37.9 88.8 13451 11557 152 BXRC-50C4001-D-7x-SE 70 525 27.7 14.6 2862 2615 197 700 28.2 19.8 3736 3397 189 1050 29.0 30.5 5530 4977 182 1575 30.4 47.9 8175 7202 171 2100 31.5 66.2 10530 9048 159 BXRC-50E4001-B-7x-SE 80 450 33.1 14.9 2826 2582 189 600 33.8 20.3 3711 3374 183 900 34.8 31.3 5472 4924 175 1350 36.5 49.2 7894 6954 160 1800 37.8 68.1 9953 8552 146 BXRC-50E4001-C-7x-SE 80 585 33.2 19.4 3674 3357 189 780 33.8 26.4 4825 4387 183 1170 34.8 40.7 7113 6402 175 1755 36.5 64.1 10262 9040 160 2340 37.9 88.8 12939 11117 146 BXRC-50E4001-D-7x-SE 80 525 27.7 14.6 2753 2515 189 700 28.2 19.8 3594 3268 182 1050 29.0 30.5 5320 4788 175 1575 30.4 47.9 7864 6928 164 2100 31.5 66.2 10130 8704 153 BXRC-50G4001-B-7x-SE 90 450 33.1 14.9 2443 2232 164 600 33.8 20.3 3208 2917 158 900 34.8 31.3 4730 4257 151 1350 36.5 49.2 6824 6011 139 1800 37.8 68.1 8603 7392 126

Performance at Commonly Used Drive Currents Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-50G4001-C-7x-SE 90 585 33.2 19.4 3176 2901 164 780 33.8 26.4 4171 3792 158 1170 34.8 40.7 6149 5534 151 1755 36.5 64.1 8871 7814 138 2340 37.9 88.8 11184 9610 126 BXRC-50G4001-D-7x-SE 90 525 27.7 14.6 2380 2174 163 700 28.2 19.8 3107 2824 157 1050 29.0 30.5 4598 4138 151 1575 30.4 47.9 6798 5988 142 2100 31.5 66.2 8756 7524 132 BXRC-56G4000-B-7x-SE 80 450 33.1 14.9 2459 2246 165 600 33.8 20.3 3229 2936 159 900 34.8 31.3 4761 4285 152 1350 36.5 49.2 6868 6050 140 1800 37.8 68.1 8660 7441 127 BXRC-56G4000-C-7x-SE 80 585 33.2 19.4 3196 2920 165 780 33.8 26.4 4198 3817 159 1170 34.8 40.7 6189 5570 152 1755 36.5 64.1 8929 7865 139 2340 37.9 88.8 11258 9673 127 BXRC-56G400x-D-7x-SE 80 525 27.7 14.6 2395 2188 165 700 28.2 19.8 3127 2843 158 1050 29.0 30.5 4628 4166 152 1575 30.4 47.9 6842 6027 143 2100 31.5 66.2 8813 7573 133 BXRC-56H4000-D-7x-SE 97 525 27.7 14.6 2162 1975 148 700 28.2 19.8 2822 2566 143 1050 29.0 30.5 4178 3760 137 1575 30.4 47.9 6176 5440 129 2100 31.5 66.2 7955 6835 120 BXRC-57C4001-B-7x-SE 70 450 33.1 14.9 2858 2611 192 600 33.8 20.3 3753 3412 185 900 34.8 31.3 5533 4980 177 1350 36.5 49.2 7983 7033 162 1800 37.8 68.1 10065 8648 148 BXRC-57C4001-C-7x-SE 70 585 33.2 19.4 3715 3394 191 780 33.8 26.4 4879 4436 185 1170 34.8 40.7 7193 6474 177 1755 36.5 64.1 10378 9142 162 2340 37.9 88.8 13085 11243 147 BXRC-57C4001-D-7x-SE 70 525 27.7 14.6 2784 2544 191 700 28.2 19.8 3635 3304 184 1050 29.0 30.5 5380 4842 177 1575 30.4 47.9 7953 7006 166 2100 31.5 66.2 10244 8802 155

Performance at Commonly Used Drive Currents Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-57E4001-B-7x-SE 80 450 33.1 14.9 2714 2480 182 600 33.8 20.3 3565 3241 176 900 34.8 31.3 5255 4730 168 1350 36.5 49.2 7582 6679 154 1800 37.8 68.1 9559 8214 140 BXRC-57E4001-C-7x-SE 80 585 33.2 19.4 3529 3224 182 780 33.8 26.4 4634 4213 176 1170 34.8 40.7 6832 6149 168 1755 36.5 64.1 9856 8683 154 2340 37.9 88.8 12427 10678 140 BXRC-57E4001-D-7x-SE 80 525 27.7 14.6 2644 2416 182 700 28.2 19.8 3452 3138 175 1050 29.0 30.5 5109 4598 168 1575 30.4 47.9 7553 6654 158 2100 31.5 66.2 9729 8359 147 BXRC-65C4001-B-7x-SE 70 450 33.1 14.9 2858 2611 192 600 33.8 20.3 3753 3412 185 900 34.8 31.3 5533 4980 177 1350 36.5 49.2 7983 7033 162 1800 37.8 68.1 10065 8648 148 BXRC-65C4001-C-7x-SE 70 585 33.2 19.4 3715 3394 191 780 33.8 26.4 4879 4436 185 1170 34.8 40.7 7193 6474 177 1755 36.5 64.1 10378 9142 162 2340 37.9 88.8 13085 11243 147 BXRC-65C4001-D-7x-SE 70 525 27.7 14.6 2784 2544 191 700 28.2 19.8 3635 3304 184 1050 29.0 30.5 5380 4842 177 1575 30.4 47.9 7953 7006 166 2100 31.5 66.2 10244 8802 155 BXRC-65E4001-B-7x-SE 80 450 33.1 14.9 2746 2509 184 600 33.8 20.3 3607 3279 178 900 34.8 31.3 5317 4785 170 1350 36.5 49.2 7671 6758 156 1800 37.8 68.1 9672 8310 142 BXRC-65E4001-C-7x-SE 80 585 33.2 19.4 3570 3262 184 780 33.8 26.4 4689 4263 178 1170 34.8 40.7 6912 6221 170 1755 36.5 64.1 9972 8785 155 2340 37.9 88.8 12573 10803 142 BXRC-65E4001-D-7x-SE 80 525 27.7 14.6 2675 2444 184 700 28.2 19.8 3492 3175 177 1050 29.0 30.5 5169 4652 170 1575 30.4 47.9 7642 6732 159 2100 31.5 66.2 9844 8458 149 Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Electrical Characteristics

Notes for Table 6: 1. Parts are tested in pulsed conditions, Tc = 25°C. Pulse width is 10ms. 2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance. 3. Bridgelux maintains a tester tolerance of ± 0.10V on forward voltage measurements. 4. Typical coefficient of forward voltage tolerance is ± 0.1mV for nominal current. 5. Thermal resistance values are based from test data of a 3000K 80 CRI product. 6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal interface material used during testing is not included in the thermal resistance value. 7. V f min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design and selection over the operating range of the product. 8. This product has been designed and manufactured per IEC 62031:2018. This product has passed dielectric withstand voltage testing at 1160 V. The working voltage designated for the insulation is 80V d.c. The maximum allowable voltage across the array must be determined in the end product application. Table 6: Electrical Characteristics Part Number Drive Current (mA) Forward Voltage Pulsed, Tc = 25ºC (V) 1, 2, 3, 8 Typical Coefficient of Forward Voltage4 ∆Vf/∆Tc (mV/ºC) Typical Thermal Resistance Junction to Case5,6 Rj-c (ºC/W) Driver Selection Voltages7 (V) Minimum Typical Maximum Vf Min. Hot Tc = 105ºC (V) Vf Max. Cold Tc = -40ºC (V) BXRC-xxx400x-B-7x-SE BXRC-xxx400x-C-7x-SE BXRC-xxx400x-D-7x-SE

Table 7: Eye Safety Risk Group (RG) Classifications Notes for Table 7: 1. Eye safety classification for the use of Bridgelux Vero SE Series LED arrays is in accordance with specification IEC/TR 62778: Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires. 2. For products classified as RG2 at 4000K, Ethr= 1847.5 lx. 3. For products classified as RG2 at 5000K Ethr= 1315.8 lx. 4. For products classified as RG2 at 6500K, Ethr= 1124.5 lx. 5. Please contact your Bridgelux sales representative for Ethr values at specific drive currents and CCTs not listed. Part Number Drive Current 5 (mA) CCT1,5 2700K/3000K 4000K2 5000K3 6500K4 BXRC-xxx400x-B-7x-SE

900 RG1 RG1 RG1 RG1

1350 RG1 RG1 RG1 RG2

1800 RG1 RG1 RG2 RG2

1170 RG1 RG1 RG1 RG1

1755 RG1 RG1 RG2 RG2

2340 RG1 RG1 RG2 RG2

1050 RG1 RG1 RG1 RG1

1575 RG1 RG1 RG1 RG2

2100 RG1 RG1 RG2 RG2

LED Junction Temperature (Tj) 150°C Storage Temperature -40°C to +105°C Operating Case Temperature1 (Tc) 105°C BXRC-xxx400x-B-7x-SE BXRC-xxx400x-C-7x-SE BXRC-xxx400x-D-7x-SE Maximum Drive Current3 1800mA 2340mA 2100mA Maximum Peak Pulsed Drive Current4 2570mA 3340mA 3000mA Maximum Reverse Voltage5 -60V -60V -50V Table 8: Maximum Ratings Notes for Table 8: 1. For IEC 62717 requirement, please consult your Bridgelux sales representative. 2. Refer to Bridgelux Application Note AN120: Assembly Considerations for Bridgelux Vero SE LED Arrays. 3. Arrays may be driven at higher currents however lumen maintenance may be reduced. 4. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed current specified. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures. 5. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating provided for reference only.

Figure 24: Drawing for Vero SE 18 LED Array Notes for Figure 24: 1. Drawings are not to scale. 2. Drawing dimensions are in millimeters. 3. Unless otherwise specified, tolerances are ±0.15 mm. 4. Mounting holes (2X) are for M3 screws. 5. Bridgelux recommends two tapped holes for mounting screws with 31.3 ± 0.10mm center-to-center spacing. 6. Screws with flat shoulders (pan, dome, button, round, truss, mushroom) provide optimal torque control. Do NOT use flat, countersink, or raised head screws. 7. The optical center of the LED Array is nominally defined by the mechanical center of the array to a tolerance of ± 0.2mm. 8. Bridgelux maintains a flatness of 0.10mm across the mounting surface of the array.

Figure 25: Warm and Neutral White Test Bins in xy Color Space Figure 26: Graph of Cool White Test Bins in xy Color Space Color Binning Information Bin Code 1750K 2000K 2500K 2700K 3000K1 3500K1 4000K1 ANSI Bin (for reference only) - - - (2580K - 2870K) (2870K - 3220K) (3220K - 3710K) (3710K - 4260K) 73 (3 SDCM) - - - (2651K - 2794K) (2968K - 3136K) (3369K - 3586K) (3851K - 4130K) 72 (2 SDCM) - - - (2674K - 2769K) (2995K - 3107K) (3404K - 3548K) (3895K - 4081K) Table 9: Warm and Neutral White xy Bin Coordinates and Associated Typical CCT Bin Code 5000K 5600K1 5700K 6500K ANSI Bin (for reference only) (4745K - 5311K) (5310K - 6020K) (5312K - 6022K) (6022K - 7042K) 74 (4 SDCM) (4801K - 5282K) (5475K - 5830K) (5395K- 5970K) (6200K - 6910K) 73 (3 SDCM) (4835K - 5215K) (5490K - 5820K) (5460K- 5891K) (6279K -6811K) Table 10: Cool White xy Bin Coordinates and Associated Typical CCT (product is hot targeted to Tc = 85°C) Note for Table 10: 1. Select configurations with a CCT of 5600K are available with center point targets at Tc = 85°C or Tc = 25°C. 2. Bridgelux maintains a tolerance of +/- 0.007 on x and y color coordinates in the CIE 1931 color Space. Note: Pulsed Test Conditions, Tc = 25°C Note for Table 9: 1. Color Binning information excludes Decor Series Class A products. Please contact your Bridgelux Sales Representative for more information. 2. Center Point for Decor Series Showcase. 3. Bridgelux maintains a tolerance of +/- 0.007 on x and y color coordinates in the CIE 1931 color Space. Note: Pulsed Test Conditions, Tc = 25°C 0.34 0.36 0.38 0.4 0.42 0.44 Y X

3 SDCM 4 SDCM

2 SDCM

0.3 0.31 0.32 0.33 0.34 0.35 0.36 0.37 0.38 0.39 Y X

4 SDCM

3 SDCM

Figure 27: Drawing for Vero SE 18 Packaging Tray Notes for Figure 27: 1. Dimensions are in millimeters. 2. Drawings are not to scale.

Bridgelux has developed a comprehensive set of application notes and design resources to assist customers in successfully designing with the Vero product family of LED array products. For all available application notes visit www.bridgelux.com. Optical Source Models Optical source models and ray set files are available for all Bridgelux products. For a list of available formats, visit www.bridgelux.com. MINOR PRODUCT CHANGE POLICY The rigorous qualification testing on products offered by Bridgelux provides performance assurance. Slight cosmetic changes that do not affect form, fit, or function may occur as Bridgelux continues product optimization. CAUTION: CHEMICAL EXPOSURE HAZARD Exposure to some chemicals commonly used in luminaire manufacturing and assembly can cause damage to the LED array. Please consult Bridgelux CAUTION: RISK OF BURN Do not touch the Vero LED array during operation. Allow the array to cool for a sufficient period of time before handling. The Vero LED array may reach elevated temperatures such that could burn skin when touched. 3D CAD Models Three dimensional CAD models depicting the product outline of all Bridgelux Vero LED arrays are available in both IGS and STEP formats. Please contact your Bridgelux sales representative for assistance. LM80 LM80 testing has been completed and the LM80 report is now available. Please contact your Bridgelux sales representative for LM-80 report. CAUTION CONTACT WITH LIGHT EMITTING SURFACE (LES) Avoid any contact with the LES. Do not touch the LES of the LED array or apply stress to the LES (yellow phosphor resin area). Contact may cause damage to the LED array. Optics and reflectors must not be mounted in contact with the LES (yellow phosphor resin area). Optical devices may be mounted on the top surface of the plastic housing of the Vero LED array. Use the mechanical features of the LED array housing, edges and/or mounting holes to locate and secure optical devices as needed. STANDARD TEST CONDITIONS Unless otherwise stated, array testing is performed at the nominal drive current.

About Bridgelux: Bridging Light and Life™ © 2023 Bridgelux, Inc. All rights reserved. Product specifications are subject to change without notice. Bridgelux, the Bridgelux stylized logo design, Vero, V Series and V Series HD are registered trademarks, and Decor Series is a trademark of Bridgelux, Inc. All other trademarks are the property of their respective owners. Bridgelux Vero SE 18 Array Series Product Data Sheet DS122 Rev. Q (07/2023)

46410 Fremont Boulevard

Fremont, CA 94538 U.S.A. Tel (925) 583-8400 www.bridgelux.com At Bridgelux, we help companies, industries and people experience the power and possibility of light. Since 2002, we’ve designed LED solutions that are high performing, energy efficient, cost effective and easy to integrate. Our focus is on light’s impact on human behavior, delivering products that create better environments, experiences and returns—both experiential and financial. And our patented technology drives new platforms for commercial and industrial luminaires. For more information about the company, please visit bridgelux.com twitter.com/Bridgelux facebook.com/Bridgelux youtube.com/user/Bridgelux linkedin.com/company/bridgelux-inc-_2 WeChat ID: BridgeluxInChina