DS121 BRIDGELUX | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 37
Technical content
Datasheet sections
Vero® SE Series is a revolutionary light source system that integrates Bridgelux’s seventh generation COB technology with poke-in connectivity enabling solder-free installation. Vero SE LED light sources streamline assembly processes, lower manufacturing cost, simplify luminaire design, improve light quality and increase design flexibility. Vero SE is available in four different light emitting surface (LES) configurations that operate reliably over a broad current range. With Vero SE, secondary connector and holder components are not required, allowing for rapid integration of arrays into fixtures and an efficient field replaceable solution. Vero SE arrays deliver increased lumen density for improved beam control and precision lighting with 2 and 3 SDCM color control standards for clean and consistent uniform lighting. Bridgelux Décor Series is our state of the art color line designed specifically for premium applications, producing unmatched LED light quality with brilliant color-rendering options and offer pleasing and inspiring lighting palettes. Bridgelux Décor Series color points are available on Vero® SE Series, Vero® Series, V Series™ and V Series™ HD. Décor Series Class A is based on human response testing, providing color points with a combined GAI and CRI metric. Décor Series™ Ultra products provide a high CRI of 97 and a minimum R9 value of 93, which emphasizes the reds and color tones to which the human eye is most receptive - perfect for the most luxurious retail shops and world renowned museums. Décor Series Ultra is also a good replacement for halogen lamps. Décor Series™ Showcase is the optimal solution for replacing ceramic metal halide lamps, incorporating the same pure white light with enhanced spectrum coverage and higher efficacy. Vero SE
Features
- Poke-in connectivity
- Efficacy of 167 lm/W typical
- Lumen output performance ranges from 511 to 6,931 lumens
- Broad range of CCT options from 2700K to 6500K
- CRI options; minimum 70, 80, and 90
- Color control: 2 and 3 SDCM for 2700K-4000K CCT
- Reliable operation at up to 2X nominal drive current
- Radial die pattern and improved lumen density
- Top side part number markings
- No exposed solder pads or electrical connections
- V f bin code backside marking Benefits
- Poke-in connectivity enables solderless, connector free installation
- Broad application coverage for interior and exterior lighting
- Flexibility for application driven lighting design requirements
- High quality, true color reproduction
- Uniform consistent white light
- Flexibility in design optimization
- Enhanced ease of use and assembly
- Ability to configure multiple Vero SE arrays in series and parallel reduces customer driver cost
- Improved inventory management and quality control
Vero SE 13 is the second smallest form factor in the product family of the next generation solid state light sources. In addition to delivering the performance and light quality required for many lighting applications, Vero SE incorporates several features to simplify the design integration and manufacturing process, accelerate time to market and reduce system costs. Please visit www. bridgelux.com for more information on the Vero SE family of products. 2D Bar code provides full manufacturing traceability Polarity indication marks simplify manufacturing operator instructions Mounting holes Optic mounting holes Tc Measurement point Radial die configuration improves lumen density and beam control Top side part number marking improves inventory management and outgoing quality control Wire release mechanisms x4 Dual poke-in connectivity Test ports for probing Product Nomenclature The part number designation for Bridgelux Vero SE LED arrays is explained as follows: 1 2 3 4 – 5 6 7 8 9 10 11 – 12 – 13 14 – 15 16 Product Family CCT Bin Options 2 = 2 SDCM 3 = 3 SDCM 4 = 4 SDCM CRI C = 70 CRI min. E = 80 CRI min. G = 90 CRI min. H = 97 CRI typ. A = Class A Array Configuration 27 = 2,700K 30 = 3,000K 35 = 3,500K 40 = 4,000K 50 = 5,000K 57 = 5,700K 65 = 6,500K BXRC – 30 E 200 0 – C – 7 3 – SE Color Targeting Designator 0 = Cold Targeted 1 = Hot Targeted C = Decor Series Showcase Gen. 7 Nominal CCT Flux Indicator 200x = 2000 lm Special Edition Zhaga Book 3 compatible mounting locations
The following product configurations are available: Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-27E2000-B-7x-SE 2700 80 450 2455 2210 34.8 15.7 157 BXRC-27E2000-C-7x-SE 2700 80 630 3438 3094 34.8 21.9 157 BXRC-27E2000-D-7x-SE 2700 80 500 2493 2244 31.8 15.9 157 BXRC-27G20H0-B-7x-SE 2700 90 450 2103 1892 34.8 15.7 134 BXRC-27G20H0-C-7x-SE 2700 90 630 2944 2649 34.8 21.9 134 BXRC-27G20H0-D-7x-SE 2700 90 500 2135 1921 31.8 15.9 134 BXRC-27G2000-B-7x-SE 2700 90 450 2026 1823 34.8 15.7 129 BXRC-27G2000-C-7x-SE 2700 90 630 2836 2552 34.8 21.9 129 BXRC-27G2000-D-7x-SE 2700 90 500 2057 1851 31.8 15.9 129 BXRC-27H2000-B-7x-SE 2700 97 450 1796 1616 34.8 15.7 115 BXRC-27H2000-C-7x-SE 2700 97 630 2514 2262 34.8 21.9 115 BXRC-27H2000-D-7x-SE 2700 97 500 1823 1641 31.8 15.9 115 BXRC-30C2001-B-7x-SE 3000 70 450 2732 2459 34.8 15.7 174 BXRC-30C2001-C-7x-SE 3000 70 630 3824 3442 34.8 21.9 174 BXRC-30C2001-D-7x-SE 3000 70 500 2774 2496 31.8 15.9 174 BXRC-30E2000-B-7x-SE 3000 80 450 2609 2348 34.8 15.7 167 BXRC-30E2000-C-7x-SE 3000 80 630 3653 3287 34.8 21.9 167 BXRC-30E2000-D-7x-SE 3000 80 500 2649 2384 31.8 15.9 167 BXRC-30G20H0-B-7x-SE 3000 90 450 2210 1989 34.8 15.7 141 BXRC-30G20H0-C-7x-SE 3000 90 630 3094 2785 34.8 21.9 141 BXRC-30G20H0-D-7x-SE 3000 90 500 2244 2019 31.8 15.9 141 BXRC-30G2000-B-7x-SE 3000 90 450 2118 1906 34.8 15.7 135 BXRC-30G2000-C-7x-SE 3000 90 630 2965 2669 34.8 21.9 135 BXRC-30G2000-D-7x-SE 3000 90 500 2150 1935 31.8 15.9 135 BXRC-30G200C-B-7x-SE 3000 90 450 2053 1848 34.8 15.8 130 BXRC-30G200C-D-7x-SE 3000 90 500 2072 1865 31.8 15.9 130 BXRC-30H2000-B-7x-SE 3000 97 450 1918 1727 34.8 15.7 123 BXRC-30H2000-C-7x-SE 3000 97 630 2686 2417 34.8 21.9 123 BXRC-30H2000-D-7x-SE 3000 97 500 1948 1753 31.8 15.9 123 BXRC-30A2001-B-7x-SE8,9 3000 93 450 1903 1713 34.8 15.7 122 BXRC-30A2001-C-7x-SE8,9 3000 93 630 2664 2398 34.8 21.9 122 BXRC-30A2001-D-7x-SE8,9 3000 93 500 1932 1739 31.8 15.9 122 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance.
Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-35E2000-B-7x-SE 3500 80 450 2670 2403 34.8 15.7 171 BXRC-35E2000-C-7x-SE 3500 80 630 3738 3365 34.8 21.9 171 BXRC-35E2000-D-7x-SE 3500 80 500 2711 2440 31.8 15.9 171 BXRC-35G2000-B-7x-SE 3500 90 450 2195 1975 34.8 15.7 140 BXRC-35G2000-C-7x-SE 3500 90 630 3072 2765 34.8 21.9 140 BXRC-35G2000-D-7x-SE 3500 90 500 2228 2005 31.8 15.9 140 BXRC-35A2001-B-7x-SE8,9 3500 93 450 2026 1823 34.8 15.7 129 BXRC-35A2001-C-7x-SE8,9 3500 93 630 2836 2552 34.8 21.9 129 BXRC-35A2001-D-7x-SE8,9 3500 93 500 2057 1851 31.8 15.9 129 BXRC-40C2001-B-7x-SE 4000 70 450 2808 2528 34.8 15.7 179 BXRC-40C2001-C-7x-SE 4000 70 630 3932 3539 34.8 21.9 179 BXRC-40C2001-D-7x-SE 4000 70 500 2852 2566 31.8 15.9 179 BXRC-40E2000-B-7x-SE 4000 80 450 2686 2417 34.8 15.7 172 BXRC-40E2000-C-7x-SE 4000 80 630 3760 3384 34.8 21.9 172 BXRC-40E2000-D-7x-SE 4000 80 500 2727 2454 31.8 15.9 172 BXRC-40G2000-B-7x-SE 4000 90 450 2241 2017 34.8 15.7 143 BXRC-40G2000-C-7x-SE 4000 90 630 3137 2823 34.8 21.9 143 BXRC-40G2000-D-7x-SE 4000 90 500 2275 2047 31.8 15.9 143 BXRC-40H2000-B-7x-SE 4000 97 450 2026 1823 34.8 15.7 129 BXRC-40H2000-C-7x-SE 4000 97 630 2836 2552 34.8 21.9 129 BXRC-40H2000-D-7x-SE 4000 97 500 2057 1851 31.8 15.9 129 BXRC-40A2001-B-7x-SE8,9 4000 93 450 2195 1975 34.8 15.7 140 BXRC-40A2001-C-7x-SE8,9 4000 93 630 3072 2765 34.8 21.9 140 BXRC-40A2001-D-7x-SE8,9 4000 93 500 2228 2005 31.8 15.9 140 BXRC-50C2001-B-7x-SE 5000 70 450 2824 2541 34.8 15.7 180 BXRC-50C2001-C-7x-SE 5000 70 630 3953 3558 34.8 21.9 180 BXRC-50C2001-D-7x-SE 5000 70 500 2867 2580 31.8 15.9 180 BXRC-50E2001-B-7x-SE 5000 80 450 2716 2445 34.8 15.7 173 BXRC-50E2001-C-7x-SE 5000 80 630 3803 3423 34.8 21.9 173 BXRC-50E2001-D-7x-SE 5000 80 500 2758 2482 31.8 15.9 173 BXRC-50G2001-B-7x-SE 5000 90 450 2348 2113 34.8 15.7 150 BXRC-50G2001-C-7x-SE 5000 90 630 3287 2959 34.8 21.9 150 BXRC-50G2001-D-7x-SE 5000 90 500 2384 2146 31.8 15.9 150 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance.
Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-57C2001-B-7x-SE 5700 70 450 2747 2472 34.8 15.7 175 BXRC-57C2001-C-7x-SE 5700 70 630 3846 3461 34.8 21.9 175 BXRC-57C2001-D-7x-SE 5700 70 500 2789 2510 31.8 15.9 175 BXRC-57E2001-B-7x-SE 5700 80 450 2609 2348 34.8 15.7 167 BXRC-57E2001-C-7x-SE 5700 80 630 3653 3287 34.8 21.9 167 BXRC-57E2001-D-7x-SE 5700 80 500 2649 2384 31.8 15.9 167 BXRC-65C2001-B-7x-SE 6500 70 450 2747 2472 34.8 15.7 175 BXRC-65C2001-C-7x-SE 6500 70 630 3846 3461 34.8 21.9 175 BXRC-65C2001-D-7x-SE 6500 70 500 2789 2510 31.8 15.9 175 BXRC-65E2001-B-7x-SE 6500 80 450 2640 2376 34.8 15.7 169 BXRC-65E2001-C-7x-SE 6500 80 630 3696 3326 34.8 21.9 169 BXRC-65E2001-D-7x-SE 6500 80 500 2680 2412 31.8 15.9 169 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance.
Table 2: Selection Guide, Stabilized DC Performance (Tc = 70°C) 7,8 Part Number Nominal CCT1 (K) GAI2 CRI3 Nominal Drive Current4 (mA) Typical DC Flux5,6 Tc = 70ºC (lm) Minimum DC Flux6,9 Tc = 70ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-30A2001-B-7x-SE 3000 80 93 450 1770 1557 34.4 15.5 115 BXRC-30A2001-C-7x-SE 3000 80 93 630 2478 2180 34.4 21.6 115 BXRC-30A2001-D-7x-SE 3000 80 93 500 1797 1581 31.2 15.6 115 BXRC-35A2001-B-7x-SE 3500 80 93 450 1884 1658 34.4 15.5 122 BXRC-35A2001-C-7x-SE 3500 80 93 630 2638 2321 34.4 21.6 122 BXRC-35A2001-D-7x-SE 3500 80 93 500 1913 1683 31.2 15.6 123 BXRC-40A2001-B-7x-SE 4000 80 93 450 2041 1796 34.4 15.5 132 BXRC-40A2001-C-7x-SE 4000 80 93 630 2857 2514 34.4 21.6 132 BXRC-40A2001-D-7x-SE 4000 80 93 500 2072 1824 31.2 15.6 133 Notes for Table 2: 1. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 2. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance. 3. CRI Values are specified as typical. 4. Drive current is referred to as nominal drive current. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 8. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at specified temperature. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 9. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected
Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-27E2000-B-7x-SE 2700 80 450 2210 1989 33.9 15.3 145 BXRC-27E2000-C-7x-SE 2700 80 630 3094 2785 33.9 21.4 145 BXRC-27E2000-D-7x-SE 2700 80 500 2244 2019 30.9 15.5 145 BXRC-27G20H0-B-7x-SE 2700 90 450 1892 1703 33.9 15.3 124 BXRC-27G20H0-C-7x-SE 2700 90 630 2649 2384 33.9 21.4 124 BXRC-27G20H0-D-7x-SE 2700 90 500 1921 1729 30.9 15.5 124 BXRC-27G2000-B-7x-SE 2700 90 450 1823 1641 33.9 15.3 119 BXRC-27G2000-C-7x-SE 2700 90 630 2552 2297 33.9 21.4 119 BXRC-27G2000-D-7x-SE 2700 90 500 1851 1666 30.9 15.5 120 BXRC-27H2000-B-7x-SE 2700 97 450 1616 1454 33.9 15.3 106 BXRC-27H2000-C-7x-SE 2700 97 630 2262 2036 33.9 21.4 106 BXRC-27H2000-D-7x-SE 2700 97 500 1641 1477 30.9 15.5 106 BXRC-30C2001-B-7x-SE 3000 70 450 2459 2213 33.9 15.3 161 BXRC-30C2001-C-7x-SE 3000 70 630 3442 3098 33.9 21.4 161 BXRC-30C2001-D-7x-SE 3000 70 500 2496 2247 30.9 15.5 161 BXRC-30E2000-B-7x-SE 3000 80 450 2348 2113 33.9 15.3 154 BXRC-30E2000-C-7x-SE 3000 80 630 3287 2959 33.9 21.4 154 BXRC-30E2000-D-7x-SE 3000 80 500 2384 2146 30.9 15.5 154 BXRC-30G20H0-B-7x-SE 3000 90 450 1989 1790 33.9 15.3 130 BXRC-30G20H0-C-7x-SE 3000 90 630 2785 2506 33.9 21.4 130 BXRC-30G20H0-D-7x-SE 3000 90 500 2019 1817 30.9 15.5 131 BXRC-30G2000-B-7x-SE 3000 90 450 1906 1715 33.9 15.3 125 BXRC-30G2000-C-7x-SE 3000 90 630 2669 2402 33.9 21.4 125 BXRC-30G2000-D-7x-SE 3000 90 500 1935 1742 30.9 15.5 125 BXRC-30G200C-B-7x-SE 3000 90 450 1848 1663 33.9 15.3 121 BXRC-30G200C-D-7x-SE 3000 90 500 1865 1679 30.9 15.5 121 BXRC-30H2000-B-7x-SE 3000 97 450 1727 1554 33.9 15.3 113 BXRC-30H2000-C-7x-SE 3000 97 630 2417 2175 33.9 21.4 113 BXRC-30H2000-D-7x-SE 3000 97 500 1753 1578 30.9 15.5 113 BXRC-30A2001-B-7x-SE7,8 3000 93 450 1713 1541 33.9 15.3 112 BXRC-30A2001-C-7x-SE7,8 3000 93 630 2398 2158 33.9 21.4 112 BXRC-30A2001-D-7x-SE7,8 3000 93 500 1739 1565 30.9 15.5 112 Notes for Table 3: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance.
Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-35E2000-B-7x-SE 3500 80 450 2403 2163 33.9 15.3 158 BXRC-35E2000-C-7x-SE 3500 80 630 3365 3028 33.9 21.4 158 BXRC-35E2000-D-7x-SE 3500 80 500 2440 2196 30.9 15.5 158 BXRC-35G2000-B-7x-SE 3500 90 450 1975 1778 33.9 15.3 129 BXRC-35G2000-C-7x-SE 3500 90 630 2765 2489 33.9 21.4 129 BXRC-35G2000-D-7x-SE 3500 90 500 2005 1805 30.9 15.5 130 BXRC-35A2001-B-7x-SE7,8 3500 93 450 1823 1641 33.9 15.3 119 BXRC-35A2001-C-7x-SE7,8 3500 93 630 2552 2297 33.9 21.4 119 BXRC-35A2001-D-7x-SE7,8 3500 93 500 1851 1666 30.9 15.5 120 BXRC-40C2001-B-7x-SE 4000 70 450 2528 2275 33.9 15.3 166 BXRC-40C2001-C-7x-SE 4000 70 630 3539 3185 33.9 21.4 166 BXRC-40C2001-D-7x-SE 4000 70 500 2566 2310 30.9 15.5 166 BXRC-40E2000-B-7x-SE 4000 80 450 2417 2175 33.9 15.3 158 BXRC-40E2000-C-7x-SE 4000 80 630 3384 3046 33.9 21.4 158 BXRC-40E2000-D-7x-SE 4000 80 500 2454 2209 30.9 15.5 159 BXRC-40G2000-B-7x-SE 4000 90 450 2017 1815 33.9 15.3 132 BXRC-40G2000-C-7x-SE 4000 90 630 2823 2541 33.9 21.4 132 BXRC-40G2000-D-7x-SE 4000 90 500 2047 1843 30.9 15.5 132 BXRC-40H2000-B-7x-SE 4000 97 450 1823 1641 33.9 15.3 119 BXRC-40H2000-C-7x-SE 4000 97 630 2552 2297 33.9 21.4 119 BXRC-40H2000-D-7x-SE 4000 97 500 1851 1666 30.9 15.5 120 BXRC-40A2001-B-7x-SE7,8 4000 93 450 1975 1778 33.9 15.3 129 BXRC-40A2001-C-7x-SE7,8 4000 93 630 2765 2489 33.9 21.4 129 BXRC-40A2001-D-7x-SE7,8 4000 93 500 2005 1805 30.9 15.5 130 BXRC-50C2001-B-7x-SE 5000 70 450 2541 2287 33.9 15.3 167 BXRC-50C2001-C-7x-SE 5000 70 630 3558 3202 33.9 21.4 167 BXRC-50C2001-D-7x-SE 5000 70 500 2580 2322 30.9 15.5 167 BXRC-50E2001-B-7x-SE 5000 80 450 2445 2200 33.9 15.3 160 BXRC-50E2001-C-7x-SE 5000 80 630 3423 3080 33.9 21.4 160 BXRC-50E2001-D-7x-SE 5000 80 500 2482 2234 30.9 15.5 161 BXRC-50G2001-B-7x-SE 5000 90 450 2113 1902 33.9 15.3 139 BXRC-50G2001-C-7x-SE 5000 90 630 2959 2663 33.9 21.4 139 BXRC-50G2001-D-7x-SE 5000 90 500 2146 1931 30.9 15.5 139 Notes for Table 3: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance. x-SE
Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-57C2001-B-7x-SE 5700 70 450 2472 2225 33.9 15.3 162 BXRC-57C2001-C-7x-SE 5700 70 630 3461 3115 33.9 21.4 162 BXRC-57C2001-D-7x-SE 5700 70 500 2510 2259 30.9 15.5 162 BXRC-57E2001-B-7x-SE 5700 80 450 2348 2113 33.9 15.3 154 BXRC-57E2001-C-7x-SE 5700 80 630 3287 2959 33.9 21.4 154 BXRC-57E2001-D-7x-SE 5700 80 500 2384 2146 30.9 15.5 154 BXRC-65C2001-B-7x-SE 6500 70 450 2472 2225 33.9 15.3 162 BXRC-65C2001-C-7x-SE 6500 70 630 3461 3115 33.9 21.4 162 BXRC-65C2001-D-7x-SE 6500 70 500 2510 2259 30.9 15.5 162 BXRC-65E2001-B-7x-SE 6500 80 450 2376 2138 33.9 15.3 156 BXRC-65E2001-C-7x-SE 6500 80 630 3326 2993 33.9 21.4 156 BXRC-65E2001-D-7x-SE 6500 80 500 2412 2171 30.9 15.5 156 Notes for Table 3: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance.
European Product Registry for Energy Labeling The European Product Registry for Energy Labeling (EPREL) is defined in the EU Regulation 2017/1369 to provide import- ant energy efficiency information to consumers. Together with Energy Labeling Regulation ELR (EU) 2019/2015 which was amended by regulation (EU) 2021/340 for energy labelling of light sources, manufacturers are required to declare an ener- gy class based on key technical specifications from each of their product and register it in an open data base managed by EPREL It is now a legal requirement for a vendor of light sources to upload information about their products into the EPREL database before placing these products on the market in the EU. Table 4 below provides a list of part numbers that are in compliance with ELR and are currently listed in the EPREL data- base. At Bridgelux, we are fully committed to supplying products that are compliant with pertinent laws, rules, and obligation imposed by relevant government bodies including the European Energy Labeling regulation. Customers can use these products with full confidence for any projects that fall under the ELR. Table 4: Part numbers registered in European Product Registry for Energy Labeling PART NUMBER1 CCT (K) CRI Current2 (mA) Vf (V) Useful flux3 (Φuse) at 85C (lm) Pow- er (W) Efficacy (lm/W) Energy efficiency class4 Regis- tration No URL to Product Information Sheet in EPREL Database Notes for Table 4: 1. All device listed here must be disposed as e-waste upon its end of life according to local country guideline in each country. 2. For information on performance values at alternative drive conditions. please refer to the Product Selection Guide, Absolute Maximum Rating Table and Performance Curves in this data sheet. 3. For a definition of useful luminous flux (ΦΦuse), please see the ELR regulations at https:/ /tinyurl.com/4b6zvt4m. 4. EPREL requires an arrow symbol containing the letter of the energy efficiency class to be displayed. on technical promotional material. Refer to this energy efficiency class column for specific energy efficiency class on each part number.
European Product Registry for Energy Labeling Table 4: Part numbers registered in European Product Registry for Energy Labeling (Continued) PART NUMBER1 CCT (K) CRI Current2 (mA) Vf (V) Useful flux3 (Φuse) at 85C (lm) Pow- er (W) Efficacy (lm/W) Energy efficiency class4 Regis- tration No URL to Product Information Sheet in EPREL Database Notes for Table 4: 1. All device listed here must be disposed as e-waste upon its end of life according to local country guideline in each country. 2. For information on performance values at alternative drive conditions. please refer to the Product Selection Guide, Absolute Maximum Rating Table and Performance Curves in this data sheet. 3. For a definition of useful luminous flux (ΦΦuse), please see the ELR regulations at https:/ /tinyurl.com/4b6zvt4m. 4. EPREL requires an arrow symbol containing the letter of the energy efficiency class to be displayed. on technical promotional material. Refer to this energy efficiency class column for specific energy efficiency class on each part number.
European Product Registry for Energy Labeling Table 4: Part numbers registered in European Product Registry for Energy Labeling (Continued) PART NUMBER1 CCT (K) CRI Current2 (mA) Vf (V) Useful flux3 (Φuse) at 85C (lm) Pow- er (W) Efficacy (lm/W) Energy efficiency class4 Regis- tration No URL to Product Information Sheet in EPREL Database Notes for Table 4: 1. All device listed here must be disposed as e-waste upon its end of life according to local country guideline in each country. 2. For information on performance values at alternative drive conditions. please refer to the Product Selection Guide, Absolute Maximum Rating Table and Performance Curves in this data sheet. 3. For a definition of useful luminous flux (ΦΦuse), please see the ELR regulations at https:/ /tinyurl.com/4b6zvt4m. 4. EPREL requires an arrow symbol containing the letter of the energy efficiency class to be displayed. on technical promotional material. Refer to this energy efficiency class column for specific energy efficiency class on each part number.
Performance at Commonly Used Drive Currents Vero SE LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. Vero SE may also be driven at other drive currents dependent on specific application design requirements. The performance at any drive current can be derived from the current vs. voltage characteristics shown in Figures 1, 2 & 3 and the flux vs. current characteristics shown in Figures 4, 5 & 6. The performance at commonly used drive currents is summarized in Table 5. Table 5: Product Performance at Commonly Used Drive Currents Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-27E2000-B-7x-SE 80 113 32.1 3.6 651 592 180 225 33.0 7.4 1267 1148 170 450 34.8 15.7 2455 2210 157 675 36.1 24.3 3541 3157 145 900 37.3 33.6 4547 4009 136 BXRC-27E2000-C-7x-SE 80 158 32.1 5.1 911 829 180 315 33.0 10.4 1773 1608 170 630 34.8 21.9 3438 3094 157 945 36.1 34.1 4958 4420 145 1260 37.3 47.0 6366 5612 136 BXRC-27E2000-D-7x-SE 80 125 29.6 3.7 665 605 180 250 30.3 7.6 1293 1172 170 500 31.8 15.9 2493 2244 157 750 33.2 24.9 3622 3228 145 1000 34.4 34.4 4666 4114 136 BXRC-27G20H0-B-7x-SE 90 113 32.1 3.6 557 507 154 225 33.0 7.4 1084 983 146 450 34.8 15.7 2103 1892 134 675 36.1 24.3 3032 2703 125 900 37.3 33.6 3893 3433 116 BXRC-27G20H0-C-7x-SE 90 158 32.1 5.1 780 710 154 315 33.0 10.4 1518 1376 146 630 34.8 21.9 2944 2649 134 945 36.1 34.1 4245 3784 125 1260 37.3 47.0 5451 4806 116 BXRC-27G20H0-D-7x-SE 90 125 29.6 3.7 570 518 154 250 30.3 7.6 1107 1004 146 500 31.8 15.9 2135 1921 134 750 33.2 24.9 3101 2764 125 1000 34.4 34.4 3995 3522 116 BXRC-27G2000-B-7x-SE 90 113 32.1 3.6 537 488 149 225 33.0 7.4 1045 947 141 450 34.8 15.7 2026 1823 129 675 36.1 24.3 2921 2604 120 900 37.3 33.6 3751 3307 112 BXRC-27G2000-C-7x-SE 90 158 32.1 5.1 752 684 149 315 33.0 10.4 1463 1326 141 630 34.8 21.9 2836 2552 129 945 36.1 34.1 4090 3646 120 1260 37.3 47.0 5252 4630 112 Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-27G2000-D-7x-SE 90 125 29.6 3.7 549 499 149 250 30.3 7.6 1067 967 141 500 31.8 15.9 2057 1851 129 750 33.2 24.9 2988 2663 120 1000 34.4 34.4 3849 3394 112 BXRC-27H2000-B-7x-SE 80 113 32.1 3.6 476 433 132 225 33.0 7.4 926 840 125 450 34.8 15.7 1796 1616 115 675 36.1 24.3 2590 2308 106 900 37.3 33.6 3325 2932 99 BXRC-27H2000-C-7x-SE 80 158 32.1 5.1 666 606 132 315 33.0 10.4 1297 1176 125 630 34.8 21.9 2514 2262 115 945 36.1 34.1 3625 3232 106 1260 37.3 47.0 4655 4104 99 BXRC-27H2000-D-7x-SE 80 125 29.6 3.7 486 442 132 250 30.3 7.6 946 857 125 500 31.8 15.9 1823 1641 115 750 33.2 24.9 2648 2361 106 1000 34.4 34.4 3412 3008 99 BXRC-30C2001-B-7x-SE 70 113 32.1 3.6 724 659 200 225 33.0 7.4 1409 1277 190 450 34.8 15.7 2732 2459 174 675 36.1 24.3 3940 3512 162 900 37.3 33.6 5058 4460 151 BXRC-30C2001-C-7x-SE 70 158 32.1 5.1 1014 922 200 315 33.0 10.4 1973 1788 190 630 34.8 21.9 3824 3442 174 945 36.1 34.1 5515 4917 162 1260 37.3 47.0 7082 6244 151 BXRC-30C2001-D-7x-SE 70 125 29.6 3.7 740 673 200 250 30.3 7.6 1439 1304 190 500 31.8 15.9 2774 2496 174 750 33.2 24.9 4029 3592 162 1000 34.4 34.4 5191 4576 151 BXRC-30E2000-B-7x-SE 80 113 32.1 3.6 692 629 191 225 33.0 7.4 1346 1220 181 450 34.8 15.7 2609 2348 167 675 36.1 24.3 3763 3354 155 900 37.3 33.6 4831 4259 144 BXRC-30E2000-C-7x-SE 80 158 32.1 5.1 968 881 191 315 33.0 10.4 1884 1708 181 630 34.8 21.9 3653 3287 167 945 36.1 34.1 5268 4696 155 1260 37.3 47.0 6763 5963 144 Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-30E2000-D-7x-SE 80 125 29.6 3.7 707 643 191 250 30.3 7.6 1374 1246 181 500 31.8 15.9 2649 2384 167 750 33.2 24.9 3848 3430 155 1000 34.4 34.4 4957 4371 144 BXRC-30G20H0-B-7x-SE 90 113 32.1 3.6 586 533 162 225 33.0 7.4 1140 1033 153 450 34.8 15.7 2210 1989 141 675 36.1 24.3 3187 2841 131 900 37.3 33.6 4092 3608 122 BXRC-30G20H0-C-7x-SE 90 158 32.1 5.1 820 746 162 315 33.0 10.4 1596 1447 153 630 34.8 21.9 3094 2785 141 945 36.1 34.1 4462 3978 131 1260 37.3 47.0 5729 5051 122 BXRC-30G20H0-D-7x-SE 90 125 29.6 3.7 599 544 162 250 30.3 7.6 1164 1055 153 500 31.8 15.9 2244 2019 141 750 33.2 24.9 3259 2906 131 1000 34.4 34.4 4199 3702 122 BXRC-30G2000-B-7x-SE 90 113 32.1 3.6 561 511 155 225 33.0 7.4 1092 990 147 450 34.8 15.7 2118 1906 135 675 36.1 24.3 3054 2723 125 900 37.3 33.6 3922 3458 117 BXRC-30G2000-C-7x-SE 90 158 32.1 5.1 786 715 155 315 33.0 10.4 1529 1387 147 630 34.8 21.9 2965 2669 135 945 36.1 34.1 4276 3812 125 1260 37.3 47.0 5490 4841 117 BXRC-30G2000-D-7x-SE 90 125 29.6 3.7 574 522 155 250 30.3 7.6 1115 1011 147 500 31.8 15.9 2150 1935 135 750 33.2 24.9 3124 2785 125 1000 34.4 34.4 4024 3548 117 BXRC-30G200C-B-7x-SE 90 113 32.1 3.6 544 495 151 225 33.0 7.4 1059 960 143 450 34.8 15.7 2053 1848 131 675 36.1 24.3 2961 2639 122 900 37.3 33.6 3801 3352 113 BXRC-30G200C-D-7x-SE 90 125 29.6 3.7 553 503 150 250 30.3 7.6 1075 975 142 500 31.8 15.9 2072 1865 130 750 33.2 24.9 3010 2684 121 1000 34.4 34.4 3878 3419 113 Performance at Commonly Used Drive Currents Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-30H2000-B-7x-SE 80 113 32.1 3.6 509 463 141 225 33.0 7.4 989 897 133 450 34.8 15.7 1918 1727 123 675 36.1 24.3 2767 2466 114 900 37.3 33.6 3552 3132 106 BXRC-30H2000-C-7x-SE 80 158 32.1 5.1 712 648 141 315 33.0 10.4 1385 1256 133 630 34.8 21.9 2686 2417 123 945 36.1 34.1 3873 3453 114 1260 37.3 47.0 4973 4385 106 BXRC-30H2000-D-7x-SE 80 125 29.6 3.7 520 473 141 250 30.3 7.6 1010 916 133 500 31.8 15.9 1948 1753 123 750 33.2 24.9 2829 2522 114 1000 34.4 34.4 3645 3214 106 BXRC-30A2001-B-7x-SE 93 113 32.1 3.6 504 459 140 225 33.0 7.4 982 890 132 450 34.8 15.7 1903 1713 122 675 36.1 24.3 2744 2447 113 900 37.3 33.6 3524 3107 105 BXRC-30A2001-C-7x-SE 93 158 32.1 5.1 706 642 140 315 33.0 10.4 1374 1246 132 630 34.8 21.9 2664 2398 122 945 36.1 34.1 3842 3425 113 1260 37.3 47.0 4933 4350 105 BXRC-30A2001-D-7x-SE 93 125 29.6 3.7 516 469 140 250 30.3 7.6 1002 909 132 500 31.8 15.9 1932 1739 122 750 33.2 24.9 2807 2502 113 1000 34.4 34.4 3616 3188 105 BXRC-35E2000-B-7x-SE 80 113 32.1 3.6 708 644 196 225 33.0 7.4 1377 1249 185 450 34.8 15.7 2670 2403 171 675 36.1 24.3 3851 3433 158 900 37.3 33.6 4945 4360 147 BXRC-35E2000-C-7x-SE 80 158 32.1 5.1 991 901 196 315 33.0 10.4 1928 1748 185 630 34.8 21.9 3738 3365 171 945 36.1 34.1 5391 4806 158 1260 37.3 47.0 6923 6104 147 BXRC-35E2000-D-7x-SE 80 125 29.6 3.7 723 658 196 250 30.3 7.6 1406 1275 185 500 31.8 15.9 2711 2440 171 750 33.2 24.9 3938 3511 158 1000 34.4 34.4 5074 4474 147 Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-35G2000-B-7x-SE 90 113 32.1 3.6 582 529 161 225 33.0 7.4 1132 1026 152 450 34.8 15.7 2195 1975 140 675 36.1 24.3 3165 2821 130 900 37.3 33.6 4064 3583 121 BXRC-35G2000-C-7x-SE 90 158 32.1 5.1 815 741 161 315 33.0 10.4 1585 1437 152 630 34.8 21.9 3072 2765 140 945 36.1 34.1 4431 3950 130 1260 37.3 47.0 5689 5016 121 BXRC-35G2000-D-7x-SE 90 125 29.6 3.7 595 541 161 250 30.3 7.6 1156 1048 152 500 31.8 15.9 2228 2005 140 750 33.2 24.9 3237 2885 130 1000 34.4 34.4 4170 3677 121 BXRC-35A2001-B-7x-SE 93 113 32.1 3.6 537 488 149 225 33.0 7.4 1045 947 141 450 34.8 15.7 2026 1823 129 675 36.1 24.3 2921 2604 120 900 37.3 33.6 3751 3307 112 BXRC-35A2001-C-7x-SE 93 158 32.1 5.1 752 684 149 315 33.0 10.4 1463 1326 141 630 34.8 21.9 2836 2552 129 945 36.1 34.1 4090 3646 120 1260 37.3 47.0 5252 4630 112 BXRC-35A2001-D-7x-SE 93 125 29.6 3.7 549 499 149 250 30.3 7.6 1067 967 141 500 31.8 15.9 2057 1851 129 750 33.2 24.9 2988 2663 120 1000 34.4 34.4 3849 3394 112 BXRC-40C2001-B-7x-SE 70 113 32.1 3.6 745 677 206 225 33.0 7.4 1449 1313 195 450 34.8 15.7 2808 2528 179 675 36.1 24.3 4050 3611 166 900 37.3 33.6 5200 4585 155 BXRC-40C2001-C-7x-SE 70 158 32.1 5.1 1042 948 206 315 33.0 10.4 2028 1839 195 630 34.8 21.9 3932 3539 179 945 36.1 34.1 5670 5055 166 1260 37.3 47.0 7281 6419 155 BXRC-40C2001-D-7x-SE 70 125 29.6 3.7 761 692 206 250 30.3 7.6 1479 1341 195 500 31.8 15.9 2852 2566 179 750 33.2 24.9 4142 3693 166 1000 34.4 34.4 5336 4705 155 Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-40E2000-B-7x-SE 80 113 32.1 3.6 712 648 197 225 33.0 7.4 1385 1256 186 450 34.8 15.7 2686 2417 172 675 36.1 24.3 3873 3453 159 900 37.3 33.6 4973 4385 148 BXRC-40E2000-C-7x-SE 80 158 32.1 5.1 997 907 197 315 33.0 10.4 1939 1758 186 630 34.8 21.9 3760 3384 172 945 36.1 34.1 5422 4834 159 1260 37.3 47.0 6962 6139 148 BXRC-40E2000-D-7x-SE 80 125 29.6 3.7 728 662 197 250 30.3 7.6 1414 1282 186 500 31.8 15.9 2727 2454 172 750 33.2 24.9 3961 3531 159 1000 34.4 34.4 5103 4499 148 BXRC-40G2000-B-7x-SE 90 113 32.1 3.6 594 540 164 225 33.0 7.4 1156 1048 156 450 34.8 15.7 2241 2017 143 675 36.1 24.3 3231 2881 133 900 37.3 33.6 4149 3658 124 BXRC-40G2000-C-7x-SE 90 158 32.1 5.1 832 756 164 315 33.0 10.4 1618 1467 156 630 34.8 21.9 3137 2823 143 945 36.1 34.1 4524 4033 133 1260 37.3 47.0 5809 5121 124 BXRC-40G2000-D-7x-SE 90 125 29.6 3.7 607 552 164 250 30.3 7.6 1180 1070 156 500 31.8 15.9 2275 2047 143 750 33.2 24.9 3305 2946 133 1000 34.4 34.4 4257 3754 124 BXRC-40H2000-B-7x-SE 97 113 32.1 3.6 537 488 149 225 33.0 7.4 1045 947 141 450 34.8 15.7 2026 1823 129 675 36.1 24.3 2921 2604 120 900 37.3 33.6 3751 3307 112 BXRC-40H2000-C-7x-SE 97 158 32.1 5.1 752 684 149 315 33.0 10.4 1463 1326 141 630 34.8 21.9 2836 2552 129 945 36.1 34.1 4090 3646 120 1260 37.3 47.0 5252 4630 112 BXRC-40H2000-D-7x-SE 97 125 29.6 3.7 549 499 149 250 30.3 7.6 1067 967 141 500 31.8 15.9 2057 1851 129 750 33.2 24.9 2988 2663 120 1000 34.4 34.4 3849 3394 112 Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-40A2001-B-7x-SE 93 113 32.1 3.6 582 529 161 225 33.0 7.4 1132 1026 152 450 34.8 15.7 2195 1975 140 675 36.1 24.3 3165 2821 130 900 37.3 33.6 4064 3583 121 BXRC-40A2001-C-7x-SE 93 158 32.1 5.1 815 741 161 315 33.0 10.4 1585 1437 152 630 34.8 21.9 3072 2765 140 945 36.1 34.1 4431 3950 130 1260 37.3 47.0 5689 5016 121 BXRC-40A2001-D-7x-SE 93 125 29.6 3.7 595 541 161 250 30.3 7.6 1156 1048 152 500 31.8 15.9 2228 2005 140 750 33.2 24.9 3237 2885 130 1000 34.4 34.4 4170 3677 121 BXRC-50C2001-B-7x-SE 70 113 32.1 3.6 749 681 207 225 33.0 7.4 1456 1320 196 450 34.8 15.7 2824 2541 180 675 36.1 24.3 4072 3630 167 900 37.3 33.6 5229 4610 156 BXRC-50C2001-C-7x-SE 70 158 32.1 5.1 1048 953 207 315 33.0 10.4 2039 1849 196 630 34.8 21.9 3953 3558 180 945 36.1 34.1 5701 5082 167 1260 37.3 47.0 7320 6454 156 BXRC-50C2001-D-7x-SE 70 125 29.6 3.7 765 696 207 250 30.3 7.6 1487 1348 196 500 31.8 15.9 2867 2580 180 750 33.2 24.9 4165 3713 167 1000 34.4 34.4 5365 4731 156 BXRC-50E2001-B-7x-SE 80 113 32.1 3.6 720 655 199 225 33.0 7.4 1401 1270 189 450 34.8 15.7 2716 2445 173 675 36.1 24.3 3917 3492 161 900 37.3 33.6 5030 4435 150 BXRC-50E2001-C-7x-SE 80 158 32.1 5.1 1008 917 199 315 33.0 10.4 1962 1778 189 630 34.8 21.9 3803 3423 173 945 36.1 34.1 5484 4889 161 1260 37.3 47.0 7042 6209 150 BXRC-50E2001-D-7x-SE 80 125 29.6 3.7 736 669 199 250 30.3 7.6 1431 1297 189 500 31.8 15.9 2758 2482 173 750 33.2 24.9 4006 3571 161 1000 34.4 34.4 5161 4551 150
Performance at Commonly Used Drive Currents Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-50G2001-B-7x-SE 90 113 32.1 3.6 622 566 172 225 33.0 7.4 1211 1098 163 450 34.8 15.7 2348 2113 150 675 36.1 24.3 3386 3019 139 900 37.3 33.6 4348 3834 130 BXRC-50G2001-C-74-SE 90 158 32.1 5.1 871 793 172 315 33.0 10.4 1696 1537 163 630 34.8 21.9 3287 2959 150 945 36.1 34.1 4741 4226 139 1260 37.3 47.0 6087 5367 130 BXRC-50G2001-D-7x-SE 90 125 29.6 3.7 636 579 172 250 30.3 7.6 1237 1121 163 500 31.8 15.9 2384 2146 150 750 33.2 24.9 3463 3087 139 1000 34.4 34.4 4462 3934 130 BXRC-57C2001-B-7x-SE 70 113 32.1 3.6 728 662 201 225 33.0 7.4 1417 1285 191 450 34.8 15.7 2747 2472 175 675 36.1 24.3 3962 3532 163 900 37.3 33.6 5087 4485 152 BXRC-57C2001-C-7x-SE 70 158 32.1 5.1 1020 927 201 315 33.0 10.4 1984 1798 191 630 34.8 21.9 3846 3461 175 945 36.1 34.1 5546 4944 163 1260 37.3 47.0 7122 6279 152 BXRC-57C2001-D-7x-SE 70 125 29.6 3.7 744 677 201 250 30.3 7.6 1447 1312 191 500 31.8 15.9 2789 2510 175 750 33.2 24.9 4052 3612 163 1000 34.4 34.4 5220 4602 152 BXRC-57E2001-B-7x-SE 80 113 32.1 3.6 692 629 191 225 33.0 7.4 1346 1220 181 450 34.8 15.7 2609 2348 167 675 36.1 24.3 3763 3354 155 900 37.3 33.6 4831 4259 144 BXRC-57E2001-C-7x-SE 80 158 32.1 5.1 968 881 191 315 33.0 10.4 1884 1708 181 630 34.8 21.9 3653 3287 167 945 36.1 34.1 5268 4696 155 1260 37.3 47.0 6763 5963 144 BXRC-57E2001-D-7x-SE 80 125 29.6 3.7 707 643 191 250 30.3 7.6 1374 1246 181 500 31.8 15.9 2649 2384 167 750 33.2 24.9 3848 3430 155 1000 34.4 34.4 4957 4371 144
Performance at Commonly Used Drive Currents Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-65C2001-B-7x-SE 70 113 32.1 3.6 728 662 201 225 33.0 7.4 1417 1285 191 450 34.8 15.7 2747 2472 175 675 36.1 24.3 3962 3532 163 900 37.3 33.6 5087 4485 152 BXRC-65C2001-C-7x-SE 70 158 32.1 5.1 1020 927 201 315 33.0 10.4 1984 1798 191 630 34.8 21.9 3846 3461 175 945 36.1 34.1 5546 4944 163 1260 37.3 47.0 7122 6279 152 BXRC-65C2001-D-7x-SE 70 125 29.6 3.7 744 677 201 250 30.3 7.6 1447 1312 191 500 31.8 15.9 2789 2510 175 750 33.2 24.9 4052 3612 163 1000 34.4 34.4 5220 4602 152 BXRC-65E2001-B-7x-SE 80 113 32.1 3.6 700 636 194 225 33.0 7.4 1361 1234 183 450 34.8 15.7 2640 2376 169 675 36.1 24.3 3807 3394 156 900 37.3 33.6 4888 4310 146 BXRC-65E2001-C-7x-SE 80 158 32.1 5.1 980 891 194 315 33.0 10.4 1906 1728 183 630 34.8 21.9 3696 3326 169 945 36.1 34.1 5330 4751 156 1260 37.3 47.0 6843 6033 146 BXRC-65E2001-D-7x-SE 80 125 29.6 3.7 715 650 194 250 30.3 7.6 1390 1260 183 500 31.8 15.9 2680 2412 169 750 33.2 24.9 3893 3471 156 1000 34.4 34.4 5016 4422 146 Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Electrical Characteristics
Notes for Table 6: 1. Parts are tested in pulsed conditions, Tc = 25°C. Pulse width is 10ms. 2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance. 3. Bridgelux maintains a tester tolerance of ± 0.10V on forward voltage measurements. 4. Typical coefficient of forward voltage tolerance is ± 0.1mV for nominal current. 5. Thermal resistance values are based from test data of a 3000K 80 CRI product. 6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal interface material used during testing is not included in the thermal resistance value. 7. V f min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design and selection over the operating range of the product. 8. This product has been designed and manufactured per IEC 62031:2014. This product has passed dielectric withstand voltage testing at 1160 V. The working voltage designated for the insulation is 80V d.c. The maximum allowable voltage across the array must be determined in the end product application. Table 6: Electrical Characteristics Part Number Drive Current (mA) Forward Voltage Pulsed, Tc = 25ºC (V) 1, 2, 3, 8 Typical Coefficient of Forward Voltage4 ∆Vf/∆Tc (mV/ºC) Typical Thermal Resistance Junction to Case5,6 Rj-c (ºC/W) Driver Selection Voltages7 (V) Minimum Typical Maximum Vf Min. Hot Tc = 105ºC (V) Vf Max. Cold Tc = -40ºC (V) BXRC-xxx200x-B-7x-SE BXRC-xxx200x-C-7x-SE BXRC-xxx200x-D-7x-SE
Table 7: Eye Safety Risk Group (RG) Classifications Notes for Table 7: 1. Eye safety classification for the use of Bridgelux Vero SE Series LED arrays is in accordance with specification IEC/TR 62778: Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires. 2. For products classified as RG2 at 4000K, Ethr= 1847.5 lx. 3. For products classified as RG2 at 5000K Ethr= 1315.8 lx. 4. For products classified as RG2 at 6500K, Ethr= 1124.5 lx. 5. Please contact your Bridgelux sales representative for Ethr values at specific drive currents and CCTs not listed. Part Number Drive Current 5 (mA) CCT1,5 2700K/3000K 4000K2 5000K3 6500K4 BXRC-xxx200x-B-7x-SE
450 RG1 RG1 RG1 RG1
675 RG1 RG1 RG1 RG2
900 RG1 RG1 RG2 RG2
630 RG1 RG1 RG1 RG1
945 RG1 RG1 RG2 RG2
1260 RG1 RG2 RG2 RG2
500 RG1 RG1 RG1 RG1
750 RG1 RG1 RG1 RG2
1000 RG1 RG1 RG2 RG2
LED Junction Temperature (Tj) 150°C Storage Temperature -40°C to +105°C Operating Case Temperature1 (Tc) 105°C BXRC-xxx200x-B-7x-SE BXRC-xxx200x-C-7x-SE BXRC-xxx200x-D-7x-SE Maximum Drive Current3 900mA 1260mA 1000mA Maximum Peak Pulsed Drive Current4 1290mA 1800mA 1430mA Maximum Reverse Voltage5 -60V -60V -55V Table 8: Maximum Ratings Notes for Table 8: 1. For IEC 62717 requirement, please consult your Bridgelux sales representative. 2. Refer to Bridgelux Application Note AN120: Assembly Considerations for Bridgelux Vero SE LED Arrays. 3. Arrays may be driven at higher currents however lumen maintenance may be reduced. 4. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed current specified. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures. 5. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating provided for reference only.
Figure 20: Drawing for Vero SE 13 LED Array Notes for Figure 20: 1. Drawings are not to scale. 2. Drawing dimensions are in millimeters. 3. Unless otherwise specified, tolerances are ±0.15mm. 4. Mounting holes (2X) are for M3 screws. 5. Bridgelux recommends two tapped holes for mounting screws with 31.3 ± 0.10mm center-to-center spacing. 6. Screws with flat shoulders (pan, dome, button, round, truss, mushroom) provide optimal torque control. Do NOT use flat, countersink, or raised head screws. 7. The optical center of the LED Array is nominally defined by the mechanical center of the array to a tolerance of ± 0.2mm. 8. Bridgelux maintains a flatness of 0.10mm across the mounting surface of the array.
Figure 21: Warm and Neutral White Test Bins in xy Color Space Color Binning Information Bin Code 2700K 3000K1 3500K1 4000K1 ANSI Bin (for reference only) (2580K - 2870K) (2870K - 3220K) (3220K - 3710K) (3710K - 4260K) 73 (3 SDCM) (2651K - 2794K) (2968K - 3136K) (3369K - 3586K) (3851K - 4130K) 72 (2 SDCM) (2674K - 2769K) (2995K - 3107K) (3404K - 3548K) (3895K - 4081K) Center Point (x,y) (0.4578, 0.4101) (0.4338, 0.403) Table 9: Warm and Neutral White xy Bin Coordinates and Associated Typical CCT Bin Code 5000K 5700K 6500K ANSI Bin (for reference only) (4745K - 5311K) (5312K - 6022K) (6022K - 7042K) 74 (4 SDCM) (4801K - 5282K) (5395K- 5970K) (6200K - 6910K) 73 (3 SDCM) (4835K - 5215K) (5460K- 5891K) (6279K -6811K) Table 10: Cool White xy Bin Coordinates and Associated Typical CCT (product is hot targeted to Tc = 85°C) Note: Pulsed Test Conditions, Tc = 25°C Note: Pulsed Test Conditions, Tc = 25°C Notes for Table 9: 1. Color Binning information excludes Decor Series Class A products. Please contact your Bridgelux Sales Representative for more information. 2. Bridgelux maintains a tolerance of +/- 0.007 on x and y color coordinates in the CIE 1931 color Space. 2. Center Point for Decor Series Showcase. Figure 22: Cool White Test Bins in xy Color Space 0.34 0.36 0.38 0.4 0.42 0.44 Y X
3 SDCM
2 SDCM
0.3 0.31 0.32 0.33 0.34 0.35 0.36 0.37 0.38 0.39 Y X
4 SDCM
Notes for Table 10: 1. Select configurations with a CCT of 5600K are available with center point targets at Tc = 85°C or Tc = 25°C. 2. Bridgelux maintains a tolerance of +/- 0.007 on x and y color coordinates in the CIE 1931 color Space.
Figure 23: Drawing for Vero SE 13 Packaging Tray Notes for Figure 23: 1. Dimensions are in millimeters. 2. Drawings are not to scale.
Bridgelux has developed a comprehensive set of application notes and design resources to assist customers in successfully designing with the Vero product family of LED array products. For all available application notes visit www.bridgelux.com. Optical Source Models Optical source models and ray set files are available for all Bridgelux products. For a list of available formats, visit www.bridgelux.com. MINOR PRODUCT CHANGE POLICY The rigorous qualification testing on products offered by Bridgelux provides performance assurance. Slight cosmetic changes that do not affect form, fit, or function may occur as Bridgelux continues product optimization. CAUTION: CHEMICAL EXPOSURE HAZARD Exposure to some chemicals commonly used in luminaire manufacturing and assembly can cause damage to the LED array. Please consult Bridgelux CAUTION: RISK OF BURN Do not touch the Vero LED array during operation. Allow the array to cool for a sufficient period of time before handling. The Vero LED array may reach elevated temperatures such that could burn skin when touched. 3D CAD Models Three dimensional CAD models depicting the product outline of all Bridgelux Vero LED arrays are available in both IGS and STEP formats. Please contact your Bridgelux sales representative for assistance. LM80 LM80 testing has been completed and the LM80 report is now available. Please contact your Bridgelux sales representative for LM-80 report. CAUTION CONTACT WITH LIGHT EMITTING SURFACE (LES) Avoid any contact with the LES. Do not touch the LES of the LED array or apply stress to the LES (yellow phosphor resin area). Contact may cause damage to the LED array. Optics and reflectors must not be mounted in contact with the LES (yellow phosphor resin area). Optical devices may be mounted on the top surface of the plastic housing of the Vero LED array. Use the mechanical features of the LED array housing, edges and/or mounting holes to locate and secure optical devices as needed. STANDARD TEST CONDITIONS Unless otherwise stated, array testing is performed at the nominal drive current.
About Bridgelux: Bridging Light and Life™ © 2023 Bridgelux, Inc. All rights reserved. Product specifications are subject to change without notice. Bridgelux, the Bridgelux stylized logo design, Vero, V Series and V Series HD are registered trademarks, and Decor Series is a trademark of Bridgelux, Inc. All other trademarks are the property of their respective owners. Bridgelux Vero SE 13 Array Series Product Data Sheet DS121 Rev. Q (07/2023)
46410 Fremont Boulevard
Fremont, CA 94538 U.S.A. Tel (925) 583-8400 www.bridgelux.com At Bridgelux, we help companies, industries and people experience the power and possibility of light. Since 2002, we’ve designed LED solutions that are high performing, energy efficient, cost effective and easy to integrate. Our focus is on light’s impact on human behavior, delivering products that create better environments, experiences and returns—both experiential and financial. And our patented technology drives new platforms for commercial and industrial luminaires. For more information about the company, please visit bridgelux.com twitter.com/Bridgelux facebook.com/Bridgelux youtube.com/user/Bridgelux linkedin.com/company/bridgelux-inc-_2 WeChat ID: BridgeluxInChina