©2022 Advanced Energy Industries, Inc. ARTESYN DS1200

1200 Watts

+3.3 VDC Standby Output Wide Range Input Voltage 90 to 264 VAC AT A GLANCEAdvanced Energy's Artesyn DS1200 series is Artesyn Embedded Power' highest power, highest density bulk front end AC-DC power supply in the industry standard 1U x 2U form factor. It accepts a wide range 90 to 264 VAC input and provides a main 12 V output plus a 3.3 V or optional 5.5 V standby output. Rated at 1,100 watts, it has a high half-load efficiency of 91%. Housed in an industry standard 1U x 2U rack-mounting package, the power supply is designed for servers and similar space-constrained applications. This series comes in two airflow versions – dc-connector to ac-connector and vice versa. SPECIAL FEATURES  Active power factor correction  EN61000-3-2 harmonic compliance  Active AC inrush control  1U X 2U form factor  21.71 W/in  +12 VDC Output  +3.3 VDC or +5.0 VDC stand-by  No minimum load required  Hot plug operation  N + 1 redundant  Internal OR’ing fets  Active current sharing (10 to 100% load)  Built-in cooling fan (40 mm x 28 mm)  I C communication interface bus  PMBus compliant  EEPROM for FRU data  Red/green bi-color LED status  Internal fan speed control  Fan fail tach output signal  Full digital control  Two years warranty SAFETY  UL/cUL 62368 (UL Recognized)  NEMKO+ CB Report EN62368  EN62368  CE Mark  China CCC  UKCA Mark

2 advancedenergy.com DS1200 ELECTRICAL SPECIFICATIONS LOGIC CONTROL Input Input range 180 to 264 VAC (1200 W) 90 to 264 VAC (1000 W) Frequency 47 to 63 Hz, single phase AC Inrush current 40 Apk maximum inrush current Efficiency > 91% typical at high line 50% load Conducted EMI FCC Subpart J EN55032 Class B Radiated EMI FCC Subpart J EN55032 Class B Power factor 0.99 typical Leakage current 1.40 mA @ 240 VAC Hold up time 12 ms minimum Output Main DC voltage +12 V @ 100 A (high line) +12 V @ 81.6 A (low line) Standby +3.3V VSB @ 6 A (5 V VSB @ 4 A available) Adjustment range ±5% on +12 V only using I2C Regulation +12 V; +5%/-5% Over current +12 V; latches off if overcurrent lasts over 1 second, otherwise it is auto recovery (See Table 1 next page) +3.3 V V SB, 9 A max (hiccup mode) Over voltage +12 V; 13.2 - 14.4 V +3.3 V VSB; 3.76 to 4.30 V Under voltage +12 V; 9 to 10.8 V (latch off) Turn-on delay 2 seconds max, 5 to 50 mS, monotonic rise Main output rise time 5 to 50 mS, monotonic rise PS_SEATED (A4) TTL logic LOW if power supply is seated into system connector. This is a short pin. A logic HIGH if the PSU is removed. PWR GOOD (C3) Active TTL high when output is within regulation limits. AC OK (B1) A low logic level if the input voltage is within allowable limits. A TTL logic HIGH level, and a 5mS early warning signal before 12.0 VDC output loss of regulation. PS_INHIBIT/PS_KILL (B4) When left open power supply operation will be inhibited. When the power supply is inserted into the system, this pin will be pull low by the system and turn the power supply on only after all other power supply pins have seated. PS ON (A1) The output will be enabled when this signal is pulled low, below 0.8 V outputs disabled when pin is driven high or left open.

advancedenergy.com 3 DS1200 ENVIRONMENTAL SPECIFICATIONS

ORDERING INFORMATION

Model Number Nominal Output Voltage Set Point Set Point Tolerance Total Regulation Minimum Current Maximum Current Output Ripple P/P Over Current Stand-by Air Flow DS1200-3 12.0 VDC ±0.2% ±5% 0 A 100 A 120 mV 118 A - 147.6 A* 3.3 V @ 6 A STD DS1200-3-002 12.0 VDC ±0.2% ±5% 0 A 100 A 120 mV 118 A - 147.6 A* 5.0 V @ 4 A STD DS1200-3-003 12.0 VDC ±0.2% ±5% 0 A 100 A 120 mV 118 A - 147.6 A* 3.3 V @ 6 A REV DS1200-3-004 12.0 VDC ±0.2% ±5% 0 A 100 A 120 mV 118 A - 147.6 A* 5.0 V @ 4 A REV *Over current latches off if overcurrent lasts over 1 seconds, otherwise it is auto recovery. Derating may apply. Operating temperature -10°C to 50°C Storage temperature -40°C to +85°C Altitude (operating) 10,000 ft Electromagnetic susceptibility/Input transients EN61000-3-2, -3-3 EN55024:1998 RoHS & lead-free compliant No tantalum caps. Humidity 20 to 90% RH, non-condensing Shock and vibration specificatons Complies with standard operating/non-operating random shock and vibration MTBF (Demonstrated) 500K Hrs at full load, 25°C

4 advancedenergy.com DS1200 MECHANICAL DRAWING Condition LED Status Standby - ON; Main output - OFF; AC PRESENT Blinking green Standby - ON; Main output - ON; Solid green Main output OCP , UVP , OVP Blinking Amber FAN_FAULT; OTP; Standby OCP/UVP Amber

advancedenergy.com 5 DS1200 DC OUTPUT CONNECTOR PINOUT ASSIGNMENT P1 - POWER SUPPLY SIDE MATING CONNECTOR (SYSTEM SIDE) Male Connector As Viewed From The Rear Of The Supply D1 D2 D3 D4 D5 D6 PB1 PB2 PB3 PB4 PB5 PB6 C1 C2 C3 C4 C5 C6 B1 B2 B3 B4 B5 B6 A1 A2 A3 A4 A5 A6

1 FCI Power Blade 51721 Series

2 Molex Power Connector

1 FCI Power Blade

2 FCI Power Blade

6 advancedenergy.com DS1200 PIN ASSIGNMENTS Pin Signal Name PB 1 Main output return PB 2 Main output return PB 3 Main output return PB 4 + Main output PB 5 + Main output PB 6 + Main output A1 PS_ON A2 Main output remote sense return A3 Spare A4 PS_SEATED (Power Supply Seated) A5 Standby A6 Standby Return B1 AC_OK (AC Input Present) B2 Main output remote sense B3 Main output current share B4 PS_INHIBIT/PS_Kill B5 Standby B6 Standby Return C1 SDA (I C Data Signal) C2 SCL (I C Clock Signal)* C3 POWER GOOD C4 Spare C5 Standby C6 Standby Return D1 A0 (I C Address BIT 0 Signal) D2 A1 (I C Address BIT 1 Signal) D3 S_INT (Alarm) D4 STANDBY RMT SENSE D5 Standby D6 Standby Return *Supports I C standard mode (100 kHz) only

ENG-DS1200-235-02 4.16 For international contact information, visit advancedenergy .com. powersales@aei.com (Sales Support) productsupport.ep@aei.com (Technical Support) +1 888 412 7832 ABOUT ADVANCED ENERGY Advanced Energy (AE) has devoted more than three decades to perfecting power for its global customers. AE designs and manufactures highly engineered, precision power conversion, measurement and control solutions for mission-critical applications and processes. Our products enable customer innovation in complex applications for a wide range of industries including semiconductor equipment, industrial, manufacturing, telecommunications, data center computing, and medical. With deep applications know-how and responsive service and support across the globe, we build collaborative partnerships to meet rapid technological developments, propel growth for our customers, and innovate the future of power. Specifications are subject to change without notice. Not responsible for errors or omissions. ©2022 Advanced Energy Industries, Inc. All rights reserved. Advanced Energy®, AE® and Artesyn™ are U.S. trademarks of Advanced Energy Industries, Inc.