DS1200 EMERSON-NETWORKPOWER | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 4

Technical content

Rev. 1.16.09_153 DS1200 1 of 4 Embedded Power for Business-Critical Continuity DS1200

1200 Watts

  • Active power factor correction
  • EN61000-3-2 harmonic compliance
  • Active AC inrush control
  • 1U X 2U form factor
  • 21.71 W / in3
  • +12 Vdc Output
  • +3.3 Vdc stand-by (5 V standby - consult factory)
  • No minimum load required
  • Hot plug operation
  • N + 1 redundant
  • Internal OR’ing fets
  • Active current sharing (10 - 100% load)
  • Built-in cooling fan (40 mm x 28 mm)
  • I2C communication interface bus
  • PMBus compliant
  • EERPOM for FRU data
  • Red/green bi-color LED status
  • Internal fan speed control
  • Fan Fail Tach Output Signal
  • INTEL, SSI Std. logic timing
  • INTEL, SSI Std. FRU data format
  • Full digital control
  • One year warranty Distributed Power Bulk Front-End Total Output Power: 1200 Watts +3.3 Vdc Stand-by Output Wide Range Input Voltage: 90 - 264 Vac Electrical Specifications Safety Input Input range: 180 - 264 (1200 W) 90 - 264 (1000 W) Frequency: 47-63 Hz, single phase AC Inrush current: 40 Apk maximum inrush current Efficiency: > 91% typical at high line 50% load Conducted EMI: FCC Subpart J EN55022 Class B Radiated EMI: FCC Subpart J EN55022 Class B Power factor: 0.99 typical Leakage current: 1.40 mA @ 240 VAC Hold up time: 12 ms minimum Output Main DC voltage: +12 V @ 100 A (high line) +12 V @ 81.6 A (low line) Stand-By: +3.3 Vsb @ 6 A (5 V @ 4 A available) Adjustment range: ±5% on +12V only using I2C Regulation: +12 Vdc; +5% / -5% Over current: +12 Vdc; latches off if overcurrent lasts over 1 second, otherwise it is auto recovery (See Table 1 next page) +3.3 Vsb, 9 A max (hiccup mode) Over voltage: +12 Vdc; 13.2 - 14.4 Vdc +3.3 Vsb; 3.76 - 4.30 Vdc Under voltage: +12 Vdc; 9 - 10.8 V (latch off) Turn-on delay: 2 second max, 5 - 50 mS, monotonic rise Main output rise time: 5 - 50 mS, monotonic rise UL/cUL 60950 (UL Recognized) NEMKO+ CB Report EN60950 EN60950 CE Mark China CCC

Rev. 1.16.09_153 DS1200 2 of 4 Embedded Power for Business-Critical Continuity

Ordering Information

Model Number Nominal Output Voltage Set Point Set Point Tolerance Total Regulation Minimum Current Maximum Current Output Ripple P/P Over Current Stand-by DS1200-3 12.0 Vdc ±0.2% ±5% 0 A 100 A 120 mV 118 A - 147.6 A* 3.3 V @ 6 A DS1200-3-002 12.0 Vdc ±0.2% ±5% 0 A 100 A 120 mV 118 A - 147.6 A* 5.0 V @ 4 A *Over current latches off if overcurrent lasts over 1 seconds, otherwise it is auto recovery. Logic Control PS_SEATED (A4): TTL logic LOW if power supply is seated into system connector. This is a short pin. A logic HIGH if the PSU is removed PWR GOOD (C3): Active TTL high when output is within regulation limits. AC OK (B1): A low logic level if the input voltage is within allowable limits. A TTL logic HIGH level, and a 5mS early warning signal before 12.0 V DC output loss of regulation. PS_INHIBIT/PS_KILL (B4): This signal is connected to a short pin on the PSU When left open power supply operation will be inhibited. When the power supply is inserted into the system, this pin will be pull low by the system and turn the power supply on only after all other power supply pins have seated. PS ON (A1): The output will be enabled when this signal is pulled low, below 0.8 V outputs disabled when pin is driven high or left open. Operating temperature: -10° to 50 °C ; 50% power derating at 70 °C Storage temperature: -40 °C to +85 °C Altitude, operating: 10,000 ft Electromagnetic susceptibility / Input transients: -EN61000-3-2, -3-3 -EN55024:1998 RoHS & lead-free compliant: No tantalum caps. Humidity: 20 to 90% RH, non-condensing Shock and vibration specificatons: Complies with Astec Std. Specifications, Q3205 MTBF (Demonstrated): 500K Hrs at full load, 40 °C Environmental Specifications

Rev. 1.16.09_153 DS1200 3 of 4 Embedded Power for Business-Critical Continuity AIRFLOW DIRECTION Condition LED Status Stand-by - ON; Main output - OFF; AC PRESENT Blinking green Stand-by - ON; Main output - ON; Solid green Main output OCP, UVP, OVP Blinking Amber FAN_FAULT; OTP; Stand-by OCP/UVP Amber Mechanical Drawing

Rev. 1.16.09_153 DS1200 4 of 4 Embedded Power for Business-Critical Continuity DC Output Connector Pinout Assignment D1 D2 D3 D4 D5 D6 PB1 PB2 PB3 PB4 PB5 PB6C1 C2 C3 C4 C5 C6 B1 B2 B3 B4 B5 B6 A1 A2 A3 A4 A5 A6 Male connector as viewed from the rear of the supply: Americas

5810 Van Allen Way

Carlsbad, CA 92008 USA Telephone: +1 760 930 4600 Facsimile: +1 760 930 0698 Europe (UK) Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 Asia (HK) 14/F, Lu Plaza

2 Wing Yip Street

Kwun Tong, Kowloon Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888 For global contact, visit: www.PowerConversion.com techsupport.embeddedpower @emerson.com While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2008 Emerson Electric Co. EmersonNetworkPower.com Embedded Computing Embedded Power Monitoring Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection Emerson Network Power. The global leader in enabling business-critical continuity. AC Power Connectivity DC Power Pin Assignments Pin Signal Name PB 1 Main output return PB 2 Main output return PB 3 Main output return PB 4 + Main output PB 5 + Main output PB 6 + Main output A1 PS_ON A2 Main output remote sense return A3 Spare A4 PS_SEATED (Power Supply Seated) A5 STAND-BY A6 STAND-BY RETURN B1 AC_OK (AC Input Present) B2 Main output remote sense B3 Main output current share B4 PS_INHIBIT / PS_Kill B5 STAND-BY B6 STAND-BY RETURN C1 SDA (I2C Data Signal) C2 SDA (I2C Clock Signal) C3 POWER GOOD C4 Spare C5 STAND-BY C6 STAND-BY RETURN D1 A0 (I2C Address BIT 0 Signal) D2 A1 (I2C Address BIT 1 Signal) D3 S_INT (Alarm) D4 STAND-BY RMT SENSE D5 STAND-BY D6 STAND-BY RETURN P1 - Power Supply Side 1. FCI Power Blade 51721 series 51721-10002406AA 2. Molex Power Connector SD-87667 series 87667-7002 Mating Connector (System Side) 1. FCI Power Blade 51741-10002406CC Straight Pins 2. FCI Power Blade 51761-10002406AALF Right Angle