Vero® SE Series is a revolutionary light source system that integrates Bridgelux’s seventh generation COB technology with poke-in connectivity enabling solder-free installation. Vero SE LED light sources streamline assembly processes, lower manufacturing cost, simplify luminaire design, improve light quality and increase design flexibility. Vero SE is available in four different light emitting surface (LES) configurations that operate reliably over a broad current range. With Vero SE, secondary connector and holder components are not required, allowing for rapid integration of arrays into fixtures and an efficient field replaceable solution. Vero SE arrays deliver increased lumen density for improved beam control and precision lighting with 2 and 3 SDCM color control standards for clean and consistent uniform lighting. Bridgelux Décor Series is our state of the art color line designed specifically for premium applications, producing unmatched LED light quality with brilliant color-rendering options and offer pleasing and inspiring lighting palettes. Bridgelux Décor Series color points are available on Vero® SE Series, Vero® Series, V Series™ and V Series™ HD. Décor Series™ Class A is based on human response testing, providing color points with a combined GAI and CRI metric. Décor Series™ Ultra products provide a high CRI of 97 and a minimum R9 value of 93, which emphasizes the reds and color tones to which the human eye is most receptive - perfect for the most luxurious retail shops and world renowned museums. Décor Series Ultra is also a good replacement for halogen lamps. Décor Series™ Street and Landmark is designed to be a direct replacement for high pressure sodium lamps. Décor Series™ Showcase is the optimal solution for replacing ceramic metal halide lamps, incorporating the same pure white light with enhanced spectrum coverage and higher efficacy. Vero SE
Features
- Poke-in connectivity
- Efficacy of 162 lm/W typical
- Broad range of CCT options from 2700K to 6500K
- CRI options: minimum 65, 70, 80, and 90
- Color control: 2 and 3 SDCM for 2700K-4000K CCT
- Reliable operation at up to 2X nominal drive current
- Radial die pattern and improved lumen density
- Top side part number markings
- No exposed solder pads or electrical connections
- V f bin code backside marking Benefits
- Poke-in connectivity enables solderless, connector free installation
- Broad application coverage for interior and exterior lighting
- Flexibility for application driven lighting design requirements
- High quality, true color reproduction
- Uniform consistent white light
- Flexibility in design optimization
- Enhanced ease of use and assembly
- Ability to configure multiple Vero SE arrays in series and parallel reduces customer driver cost
- Improved inventory management and quality control
The part number designation for Bridgelux Vero SE LED arrays is explained as follows: 1 2 3 4 – 5 6 7 8 9 10 11 – 12 – 13 14 – 15 16 Product Family CCT Bin Options 2 = 2 SDCM 3 = 3 SDCM 4 = 4 SDCM CRI B = 65 CRI min. C = 70 CRI min. E = 80 CRI min. G = 90 CRI min. H = 97 CRI typ. A = Class A Array Configuration 20 = 2,000K 27 = 2,700K 30 = 3,000K 35 = 3,500K 40 = 4,000K 50 = 5,000K 57 = 5,700K 65 = 6,500K BXRC – 30 E 100 0 – C – 7 3 – SE Color Targeting Designator 0 = Cold Targeted 1 = Hot Targeted C = Decor Series Showcase Gen. 7 Nominal CCT Flux Indicator 100x = 1000 lm Vero SE 10 is the smallest form factor in the product family of next generation solid state light sources. In addition to delivering the performance and light quality required for many lighting applications, Vero SE incorporates several features to simplify the design integration and manufacturing process, accelerate time to market and reduce system costs. Please visit www. bridgelux.com for more information on the Vero SE family of products. Special Edition Mounting holes Polarity indication marks simplify manufacturing operator instructions 2D Bar code provides full manufacturing traceability Tc Measurement point Radial die configuration improves lumen density and beam control Optic mounting holes Wire release mechanisms (x4) Dual poke-in connectivity Top side part number marking improves inventory management and outgoing quality control Test ports for probing
The following product configurations are available: Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-20B1001-B-73-SE 2000 65 270 1391 1224 34.8 9.4 148 BXRC-20B1001-D-73-SE 2000 65 350 1347 1185 26.0 9.1 148 BXRC-27E1000-B-7x-SE 2700 80 270 1417 1247 34.8 9.4 151 BXRC-27E1000-C-7x-SE 2700 80 360 1890 1663 34.8 12.5 151 BXRC-27E1000-D-7x-SE 2700 80 350 1373 1208 26.0 9.1 151 BXRC-27G10H0-B-7x-SE 2700 90 270 1214 1068 34.8 9.4 129 BXRC-27G10H0-C-7x-SE 2700 90 360 1618 1424 34.8 12.5 129 BXRC-27G10H0-D-7x-SE 2700 90 350 1175 1034 26.0 9.1 129 BXRC-27G1000-B-7x-SE 2700 90 270 1169 1029 34.8 9.4 124 BXRC-27G1000-C-7x-SE 2700 90 360 1559 1372 34.8 12.5 124 BXRC-27G1000-D-7x-SE 2700 90 350 1133 997 26.0 9.1 124 BXRC-27H1000-B-7x-SE 2700 97 270 1036 912 34.8 9.4 110 BXRC-27H1000-C-7x-SE 2700 97 360 1382 1216 34.8 12.5 110 BXRC-27H1000-D-7x-SE 2700 97 350 1004 883 26.0 9.1 110 BXRC-30C1001-B-74-SE 3000 70 270 1577 1388 34.8 9.4 168 BXRC-30C1001-C-74-SE 3000 70 360 2103 1850 34.8 12.5 168 BXRC-30C1001-D-74-SE 3000 70 350 1527 1344 26.0 9.1 168 BXRC-30E1000-B-7x-SE 3000 80 270 1506 1325 34.8 9.4 160 BXRC-30E1000-C-7x-SE 3000 80 360 2008 1767 34.8 12.5 160 BXRC-30E1000-D-7x-SE 3000 80 350 1459 1284 26.0 9.1 160 BXRC-30G10H0-B-7x-SE 3000 90 270 1276 1123 34.8 9.4 136 BXRC-30G10H0-C-7x-SE 3000 90 360 1701 1497 34.8 12.5 136 BXRC-30G10H0-D-7x-SE 3000 90 350 1235 1087 26.0 9.1 136 BXRC-30G1000-B-7x-SE 3000 90 270 1223 1076 34.8 9.4 130 BXRC-30G1000-C-7x-SE 3000 90 360 1630 1434 34.8 12.5 130 BXRC-30G1000-D-7x-SE 3000 90 350 1184 1042 26.0 9.1 130 BXRC-30G100C-B-73-SE 3000 90 270 1178 1037 34.8 9.4 125 BXRC-30G100C-D-73-SE 3000 90 350 1141 1004 26.0 9.1 125 BXRC-30H1000-B-7x-SE 3000 97 270 1107 974 34.8 9.4 118 BXRC-30H1000-C-7x-SE 3000 97 360 1476 1299 34.8 12.5 118 BXRC-30H1000-D-7x-SE 3000 97 350 1072 944 26.0 9.1 118 BXRC-30A1001-B-73-SE8,9 3000 93 270 1099 967 34.8 9.4 117 BXRC-30A1001-C-73-SE8,9 3000 93 360 1465 1289 34.8 12.5 117 BXRC-30A1001-D-73-SE8,9 3000 93 350 1064 936 26.0 9.1 117 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all oth- er products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance.
Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued) Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance. Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-35E1000-B-7x-SE 3500 80 270 1541 1356 34.8 9.4 164 BXRC-35E1000-C-7x-SE 3500 80 360 2055 1809 34.8 12.5 164 BXRC-35E1000-D-7x-SE 3500 80 350 1493 1314 26.0 9.1 164 BXRC-35G1000-B-7x-SE 3500 90 270 1267 1115 34.8 9.4 135 BXRC-35G1000-C-7x-SE 3500 90 360 1689 1486 34.8 12.5 135 BXRC-35G1000-D-7x-SE 3500 90 350 1227 1080 26.0 9.1 135 BXRC-35A1001-B-73-SE8,9 3500 93 270 1169 1029 34.8 9.4 124 BXRC-35A1001-C-73-SE8,9 3500 93 360 1559 1372 34.8 12.5 124 BXRC-35A1001-D-73-SE8,9 3500 93 350 1133 997 26.0 9.1 124 BXRC-40C1001-B-74-SE 4000 70 270 1621 1427 34.8 9.4 173 BXRC-40C1001-C-74-SE 4000 70 360 2162 1902 34.8 12.5 173 BXRC-40C1001-D-74-SE 4000 70 350 1570 1382 26.0 9.1 173 BXRC-40E1000-B-7x-SE 4000 80 270 1550 1364 34.8 9.4 165 BXRC-40E1000-C-7x-SE 4000 80 360 2067 1819 34.8 12.5 165 BXRC-40E1000-D-7x-SE 4000 80 350 1501 1321 26.0 9.1 165 BXRC-40G1000-B-7x-SE 4000 90 270 1293 1138 34.8 9.4 138 BXRC-40G1000-C-7x-SE 4000 90 360 1725 1518 34.8 12.5 138 BXRC-40G1000-D-7x-SE 4000 90 350 1253 1102 26.0 9.1 138 BXRC-40H1000-B-7x-SE 4000 97 270 1169 1029 34.8 9.4 124 BXRC-40H1000-C-7x-SE 4000 97 360 1559 1372 34.8 12.5 124 BXRC-40H1000-D-7x-SE 4000 97 350 1133 997 26.0 9.1 124 BXRC-40A1001-B-73-SE8,9 4000 93 270 1267 1115 34.8 9.4 135 BXRC-40A1001-C-73-SE8,9 4000 93 360 1689 1486 34.8 12.5 135 BXRC-40A1001-D-73-SE8,9 4000 93 350 1227 1080 26.0 9.1 135 BXRC-50C1001-B-7x-SE 5000 70 270 1630 1434 34.8 9.4 173 BXRC-50C1001-C-7x-SE 5000 70 360 2173 1913 34.8 12.5 173 BXRC-50C1001-D-7x-SE 5000 70 350 1579 1389 26.0 9.1 173 BXRC-50E1001-B-7x-SE 5000 80 270 1568 1380 34.8 9.4 167 BXRC-50E1001-C-7x-SE 5000 80 360 2091 1840 34.8 12.5 167 BXRC-50E1001-D-7x-SE 5000 80 350 1519 1336 26.0 9.1 167 BXRC-50G1001-B-7x-SE 5000 90 270 1355 1193 34.8 9.4 144 BXRC-50G1001-C-7x-SE 5000 90 360 1807 1590 34.8 12.5 144 BXRC-50G1001-D-7x-SE 5000 90 350 1313 1155 26.0 9.1 144
Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued) Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance. Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-57C1001-B-7x-SE 5700 70 270 1586 1395 34.8 9.4 169 BXRC-57C1001-C-7x-SE 5700 70 360 2114 1861 34.8 12.5 169 BXRC-57C1001-D-7x-SE 5700 70 350 1536 1351 26.0 9.1 169 BXRC-57E1001-B-7x-SE 5700 80 270 1506 1325 34.8 9.4 160 BXRC-57E1001-C-7x-SE 5700 80 360 2008 1767 34.8 12.5 160 BXRC-57E1001-D-7x-SE 5700 80 350 1459 1284 26.0 9.1 160 BXRC-65C1001-B-7x-SE 6500 70 270 1586 1395 34.8 9.4 169 BXRC-65C1001-C-7x-SE 6500 70 360 2114 1861 34.8 12.5 169 BXRC-65C1001-D-7x-SE 6500 70 350 1536 1351 26.0 9.1 169 BXRC-65E1001-B-7x-SE 6500 80 270 1524 1341 34.8 9.4 162 BXRC-65E1001-C-7x-SE 6500 80 360 2032 1788 34.8 12.5 162 BXRC-65E1001-D-7x-SE 6500 80 350 1476 1299 26.0 9.1 162
Table 2: Selection Guide, Stabilized DC Performance (Tc = 70°C) 7,8 Notes for Table 2: 1. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 2. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance. 3. CRI Values are specified as typical. 4. Drive current is referred to as nominal drive current. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 8. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at specified temperature. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 9. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. Part Number Nominal CCT1 (K) GAI2 CRI3 Nominal Drive Current4 (mA) Typical DC Flux5,6 Tc = 70ºC (lm) Minimum DC Flux6,9 Tc = 70ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-30A1001-B-73 3000 80 93 270 1022 899 34.3 9.3 110 BXRC-30A1001-C-73 3000 80 93 360 1362 1199 34.3 12.3 110 BXRC-30A1001-D-73 3000 80 93 350 989 871 25.5 8.9 111 BXRC-35A1001-B-73 3500 80 93 270 1088 957 34.3 9.3 117 BXRC-35A1001-C-73 3500 80 93 360 1450 1276 34.3 12.3 117 BXRC-35A1001-D-73 3500 80 93 350 1053 927 25.5 8.9 118 BXRC-40A1001-B-73 4000 80 93 270 1178 1037 34.3 9.3 127 BXRC-40A1001-C-73 4000 80 93 360 1571 1382 34.3 12.3 127 BXRC-40A1001-D-73 4000 80 93 350 1141 1004 25.5 8.9 128
Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 Notes for Table 3: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance. Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-20B1001-B-73-SE 2000 65 270 1252 1102 33.8 9.1 137 BXRC-20B1001-D-73-SE 2000 65 350 1212 1067 25.3 8.9 137 BXRC-27E1000-B-7x-SE 2700 80 270 1276 1123 33.8 9.1 140 BXRC-27E1000-C-7x-SE 2700 80 360 1701 1497 33.8 12.2 140 BXRC-27E1000-D-7x-SE 2700 80 350 1235 1087 25.3 8.9 140 BXRC-27G10H0-B-7x-SE 2700 90 270 1092 961 33.8 9.1 120 BXRC-27G10H0-C-7x-SE 2700 90 360 1456 1282 33.8 12.2 120 BXRC-27G10H0-D-7x-SE 2700 90 350 1058 931 25.3 8.9 120 BXRC-27G1000-B-7x-SE 2700 90 270 1052 926 33.8 9.1 115 BXRC-27G1000-C-7x-SE 2700 90 360 1403 1235 33.8 12.2 115 BXRC-27G1000-D-7x-SE 2700 90 350 1019 897 25.3 8.9 115 BXRC-27H1000-B-7x-SE 2700 97 270 933 821 33.8 9.1 102 BXRC-27H1000-C-7x-SE 2700 97 360 1244 1095 33.8 12.2 102 BXRC-27H1000-D-7x-SE 2700 97 350 903 795 25.3 8.9 102 BXRC-30C1001-B-74-SE 3000 70 270 1419 1249 33.8 9.1 155 BXRC-30C1001-C-74-SE 3000 70 360 1892 1665 33.8 12.2 155 BXRC-30C1001-D-74-SE 3000 70 350 1374 1210 25.3 8.9 155 BXRC-30E1000-B-7x-SE 3000 80 270 1355 1193 33.8 9.1 148 BXRC-30E1000-C-7x-SE 3000 80 360 1807 1590 33.8 12.2 148 BXRC-30E1000-D-7x-SE 3000 80 350 1313 1155 25.3 8.9 148 BXRC-30G10H0-B-7x-SE 3000 90 270 1148 1010 33.8 9.1 126 BXRC-30G10H0-C-7x-SE 3000 90 360 1531 1347 33.8 12.2 126 BXRC-30G10H0-D-7x-SE 3000 90 350 1112 979 25.3 8.9 126 BXRC-30G1000-B-7x-SE 3000 90 270 1100 968 33.8 9.1 120 BXRC-30G1000-C-7x-SE 3000 90 360 1467 1291 33.8 12.2 120 BXRC-30G1000-D-7x-SE 3000 90 350 1066 938 25.3 8.9 120 BXRC-30G100C-B-73-SE 3000 90 270 1060 933 34.0 9.2 115 BXRC-30G100C-D-73-SE 3000 90 350 1027 904 25.3 8.9 116 BXRC-30H1000-B-7x-SE 3000 97 270 997 877 33.8 9.1 109 BXRC-30H1000-C-7x-SE 3000 97 360 1329 1169 33.8 12.2 109 BXRC-30H1000-D-7x-SE 3000 97 350 965 849 25.3 8.9 109 BXRC-30A1001-B-73-SE7,8 3000 93 270 989 870 33.8 9.1 108 BXRC-30A1001-C-73-SE7,8 3000 93 360 1318 1160 33.8 12.2 108 BXRC-30A1001-D-73-SE7,8 3000 93 350 958 843 25.3 8.9 108
Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-35E1000-B-7x-SE 3500 80 270 1387 1221 33.8 9.1 152 BXRC-35E1000-C-7x-SE 3500 80 360 1850 1628 33.8 12.2 152 BXRC-35E1000-D-7x-SE 3500 80 350 1344 1182 25.3 8.9 152 BXRC-35G1000-B-7x-SE 3500 90 270 1140 1003 33.8 9.1 125 BXRC-35G1000-C-7x-SE 3500 90 360 1520 1338 33.8 12.2 125 BXRC-35G1000-D-7x-SE 3500 90 350 1104 972 25.3 8.9 125 BXRC-35A1001-B-73-SE7,8 3500 93 270 1052 926 33.8 9.1 115 BXRC-35A1001-C-73-SE7,8 3500 93 360 1403 1235 33.8 12.2 115 BXRC-35A1001-D-73-SE7,8 3500 93 350 1019 897 25.3 8.9 115 BXRC-40C1001-B-74-SE 4000 70 270 1459 1284 33.8 9.1 160 BXRC-40C1001-C-74-SE 4000 70 360 1945 1712 33.8 12.2 160 BXRC-40C1001-D-74-SE 4000 70 350 1413 1244 25.3 8.9 160 BXRC-40E1000-B-7x-SE 4000 80 270 1395 1228 33.8 9.1 153 BXRC-40E1000-C-7x-SE 4000 80 360 1860 1637 33.8 12.2 153 BXRC-40E1000-D-7x-SE 4000 80 350 1351 1189 25.3 8.9 153 BXRC-40G1000-B-7x-SE 4000 90 270 1164 1024 33.8 9.1 127 BXRC-40G1000-C-7x-SE 4000 90 360 1552 1366 33.8 12.2 127 BXRC-40G1000-D-7x-SE 4000 90 350 1127 992 25.3 8.9 127 BXRC-40H1000-B-7x-SE 4000 97 270 1052 926 33.8 9.1 115 BXRC-40H1000-C-7x-SE 4000 97 360 1403 1235 33.8 12.2 115 BXRC-40H1000-D-7x-SE 4000 97 350 1019 897 25.3 8.9 115 BXRC-40A1001-B-73-SE7,8 4000 93 270 1140 1003 33.8 9.1 125 BXRC-40A1001-C-73-SE7,8 4000 93 360 1520 1338 33.8 12.2 125 BXRC-40A1001-D-73-SE7,8 4000 93 350 1104 972 25.3 8.9 125 BXRC-50C1001-B-7x-SE 5000 70 270 1467 1291 33.8 9.1 161 BXRC-50C1001-C-7x-SE 5000 70 360 1956 1721 33.8 12.2 161 BXRC-50C1001-D-7x-SE 5000 70 350 1421 1250 25.3 8.9 161 BXRC-50E1001-B-7x-SE 5000 80 270 1411 1242 33.8 9.1 154 BXRC-50E1001-C-7x-SE 5000 80 360 1882 1656 33.8 12.2 154 BXRC-50E1001-D-7x-SE 5000 80 350 1367 1203 25.3 8.9 154 BXRC-50G1001-B-7x-SE 5000 90 270 1220 1073 33.8 9.1 134 BXRC-50G1001-C-7x-SE 5000 90 360 1626 1431 33.8 12.2 134 BXRC-50G1001-D-7x-SE 5000 90 350 1181 1040 25.3 8.9 133 Notes for Table 3: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance.
Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-57C1001-B-7x-SE 5700 70 270 1427 1256 33.8 9.1 156 BXRC-57C1001-C-7x-SE 5700 70 360 1903 1675 33.8 12.2 156 BXRC-57C1001-D-7x-SE 5700 70 350 1382 1216 25.3 8.9 156 BXRC-57E1001-B-7x-SE 5700 80 270 1355 1193 33.8 9.1 148 BXRC-57E1001-C-7x-SE 5700 80 360 1807 1590 33.8 12.2 148 BXRC-57E1001-D-7x-SE 5700 80 350 1313 1155 25.3 8.9 148 BXRC-65C1001-B-7x-SE 6500 70 270 1427 1256 33.8 9.1 156 BXRC-65C1001-C-7x-SE 6500 70 360 1903 1675 33.8 12.2 156 BXRC-65C1001-D-7x-SE 6500 70 350 1382 1216 25.3 8.9 156 BXRC-65E1001-B-7x-SE 6500 80 270 1371 1207 33.8 9.1 150 BXRC-65E1001-C-7x-SE 6500 80 360 1828 1609 33.8 12.2 150 BXRC-65E1001-D-7x-SE 6500 80 350 1328 1169 25.3 8.9 150 Notes for Table 3: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance.
European Product Registry for Energy Labeling The European Product Registry for Energy Labeling (EPREL) is defined in the EU Regulation 2017/1369 to provide import- ant energy efficiency information to consumers. Together with Energy Labeling Regulation ELR (EU) 2019/2015 which was amended by regulation (EU) 2021/340 for energy labelling of light sources, manufacturers are required to declare an ener- gy class based on key technical specifications from each of their product and register it in an open data base managed by EPREL It is now a legal requirement for a vendor of light sources to upload information about their products into the EPREL database before placing these products on the market in the EU. Table 4 below provides a list of part numbers that are in compliance with ELR and are currently listed in the EPREL data- base. At Bridgelux, we are fully committed to supplying products that are compliant with pertinent laws, rules, and obligation imposed by relevant government bodies including the European Energy Labeling regulation. Customers can use these products with full confidence for any projects that fall under the ELR. Table 4: Part numbers registered in European Product Registry for Energy Labeling PART NUMBER1 CCT (K) CRI Current2 (mA) Vf (V) Useful flux3 (Φuse) at 85C (lm) Pow- er (W) Efficacy (lm/W) Energy efficiency class4 Regis- tration No URL to Product Information Sheet in EPREL Database Notes for Table 4: 1. All device listed here must be disposed as e-waste upon its end of life according to local country guideline in each country. 2. For information on performance values at alternative drive conditions. please refer to the Product Selection Guide, Absolute Maximum Rating Table and Performance Curves in this data sheet. 3. For a definition of useful luminous flux (ΦΦuse), please see the ELR regulations at https:/ /tinyurl.com/4b6zvt4m. 4. EPREL requires an arrow symbol containing the letter of the energy efficiency class to be displayed. on technical promotional material. Refer to this energy efficiency class column for specific energy efficiency class on each part number.
European Product Registry for Energy Labeling Table 4: Part numbers registered in European Product Registry for Energy Labeling (Continued) PART NUMBER1 CCT (K) CRI Current2 (mA) Vf (V) Useful flux3 (Φuse) at 85C (lm) Pow- er (W) Efficacy (lm/W) Energy efficiency class4 Regis- tration No URL to Product Information Sheet in EPREL Database Notes for Table 4: 1. All device listed here must be disposed as e-waste upon its end of life according to local country guideline in each country. 2. For information on performance values at alternative drive conditions. please refer to the Product Selection Guide, Absolute Maximum Rating Table and Performance Curves in this data sheet. 3. For a definition of useful luminous flux (ΦΦuse), please see the ELR regulations at https:/ /tinyurl.com/4b6zvt4m. 4. EPREL requires an arrow symbol containing the letter of the energy efficiency class to be displayed. on technical promotional material. Refer to this energy efficiency class column for specific energy efficiency class on each part number.
European Product Registry for Energy Labeling Table 4: Part numbers registered in European Product Registry for Energy Labeling (Continued) PART NUMBER1 CCT (K) CRI Current2 (mA) Vf (V) Useful flux3 (Φuse) at 85C (lm) Pow- er (W) Efficacy (lm/W) Energy efficiency class4 Regis- tration No URL to Product Information Sheet in EPREL Database Notes for Table 4: 1. All device listed here must be disposed as e-waste upon its end of life according to local country guideline in each country. 2. For information on performance values at alternative drive conditions. please refer to the Product Selection Guide, Absolute Maximum Rating Table and Performance Curves in this data sheet. 3. For a definition of useful luminous flux (ΦΦuse), please see the ELR regulations at https:/ /tinyurl.com/4b6zvt4m. 4. EPREL requires an arrow symbol containing the letter of the energy efficiency class to be displayed. on technical promotional material. Refer to this energy efficiency class column for specific energy efficiency class on each part number.
Performance at Commonly Used Drive Currents Vero SE LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. Vero SE may also be driven at other drive currents dependent on specific application design requirements. The performance at any drive current can be derived from the current vs. voltage characteristics shown in Figures 1, 2 & 3 and the flux vs. current characteristics shown in Figures 4, 5 & 6. The performance at commonly used drive currents is summarized in Table 5. Table 5: Product Performance at Commonly Used Drive Currents Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-20B1001-B-7x-SE 65 135 33.1 4.5 728 660 163 180 33.6 6.1 958 866 158 270 34.8 9.4 1391 1252 148 405 36.2 14.7 2007 1789 137 540 37.5 20.3 2588 2282 128 BXRC-20B1001-D-73-SE 65 175 24.9 4.4 711 645 163 233 25.4 5.9 936 847 158 350 26.0 9.1 1347 1212 148 525 27.4 14.4 1986 1770 138 700 28.4 19.9 2534 2234 127 BXRC-27E1000-B-7x-SE 80 135 33.1 4.5 742 672 166 180 33.6 6.1 976 883 161 270 34.8 9.4 1417 1276 151 405 36.2 14.7 2045 1823 139 540 37.5 20.3 2637 2325 130 BXRC-27E1000-C-7x-SE 80 180 33.1 6.0 990 897 166 240 33.6 8.1 1301 1177 161 360 34.8 12.5 1890 1701 151 540 36.2 19.5 2725 2429 139 720 37.5 27.0 3512 3097 130 BXRC-27E1000-D-7x-SE 80 175 24.9 4.4 725 657 166 233 25.4 5.9 954 863 161 350 26.0 9.1 1373 1235 151 525 27.4 14.4 2024 1804 141 700 28.4 19.9 2582 2277 130 BXRC-27G10H0-B-7x-SE 90 135 33.1 4.5 635 576 142 180 33.6 6.1 836 756 138 270 34.8 9.4 1214 1355 129 405 36.2 14.7 1751 1561 119 540 37.5 20.3 2258 1991 111 BXRC-27G10H0-C-7x-SE 90 180 33.1 6.0 847 768 142 240 33.6 8.1 1114 1008 138 360 34.8 12.5 1618 1807 129 540 36.2 19.5 2333 2080 119 720 37.5 27.0 3007 2651 111 BXRC-27G10H0-D-7x-SE 90 175 24.9 4.4 620 563 142 233 25.4 5.9 817 739 138 350 26.0 9.1 1175 1313 129 525 27.4 14.4 1733 1545 121 700 28.4 19.9 2211 1950 111 Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-27G1000-B-7x-SE 90 135 33.1 4.5 612 555 137 180 33.6 6.1 805 728 133 270 34.8 9.4 1169 1052 124 405 36.2 14.7 1687 1504 115 540 37.5 20.3 2176 1918 107 BXRC-27G1000-C-7x-SE 90 180 33.1 6.0 817 740 137 240 33.6 8.1 1073 971 133 360 34.8 12.5 1559 1403 124 540 36.2 19.5 2248 2004 115 720 37.5 27.0 2897 2555 107 BXRC-27G1000-D-7x-SE 90 175 24.9 4.4 598 542 137 233 25.4 5.9 787 712 133 350 26.0 9.1 1133 1019 124 525 27.4 14.4 1669 1488 116 700 28.4 19.9 2130 1878 107 BXRC-27H1000-B-7x-SE 97 135 33.1 4.5 542 492 121 180 33.6 6.1 714 646 118 270 34.8 9.4 1036 933 110 405 36.2 14.7 1496 1333 102 540 37.5 20.3 1928 1700 95 BXRC-27H1000-C-7x-SE 97 180 33.1 6.0 724 656 121 240 33.6 8.1 952 861 118 360 34.8 12.5 1382 1244 110 540 36.2 19.5 1992 1776 102 720 37.5 27.0 2568 2264 95 BXRC-27H1000-D-7x-SE 97 175 24.9 4.4 530 480 121 233 25.4 5.9 698 631 118 350 26.0 9.1 1004 903 110 525 27.4 14.4 1480 1319 103 700 28.4 19.9 1888 1665 95 BXRC-30C1001-B-7x-SE 70 135 33.1 4.5 825 748 185 180 33.6 6.1 1086 982 179 270 34.8 9.4 1577 1419 168 405 36.2 14.7 2275 2028 155 540 37.5 20.3 2934 2587 145 BXRC-30C1001-C-7x-SE 70 180 33.1 6.0 1101 998 185 240 33.6 8.1 1448 1309 179 360 34.8 12.5 2103 1892 168 540 36.2 19.5 3031 2702 155 720 37.5 27.0 3907 3445 145 BXRC-30C1001-D-7x-SE 70 175 24.9 4.4 806 731 185 233 25.4 5.9 1061 960 179 350 26.0 9.1 1527 1374 168 525 27.4 14.4 2251 2007 157 700 28.4 19.9 2873 2533 144 Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-30E1000-B-7x-SE 80 135 33.1 4.5 788 714 177 180 33.6 6.1 1037 938 171 270 34.8 9.4 1506 1355 160 405 36.2 14.7 2173 1937 148 540 37.5 20.3 2802 2470 138 BXRC-30E1000-C-7x-SE 80 180 33.1 6.0 1052 953 177 240 33.6 8.1 1383 1250 171 360 34.8 12.5 2008 1807 160 540 36.2 19.5 2895 2581 148 720 37.5 27.0 3732 3290 138 BXRC-30E1000-D-7x-SE 80 175 24.9 4.4 770 698 177 233 25.4 5.9 1014 917 171 350 26.0 9.1 1459 1313 160 525 27.4 14.4 2150 1917 150 700 28.4 19.9 2744 2419 138 BXRC-30G10H0-B-7x-SE 90 135 33.1 4.5 667 605 150 180 33.6 6.1 878 795 145 270 34.8 9.4 1276 1148 136 405 36.2 14.7 1841 1641 125 540 37.5 20.3 2373 2093 117 BXRC-30G10H0-C-7x-SE 90 180 33.1 6.0 891 808 150 240 33.6 8.1 1171 1059 145 360 34.8 12.5 1701 1531 136 540 36.2 19.5 2452 2186 125 720 37.5 27.0 3161 2787 117 BXRC-30G10H0-D-7x-SE 90 175 24.9 4.4 652 591 150 233 25.4 5.9 859 777 145 350 26.0 9.1 1235 1112 136 525 27.4 14.4 1821 1623 127 700 28.4 19.9 2324 2049 117 BXRC-30G1000-B-7x-SE 90 135 33.1 4.5 640 580 143 180 33.6 6.1 842 761 139 270 34.8 9.4 1223 1100 130 405 36.2 14.7 1764 1573 120 540 37.5 20.3 2275 2005 112 BXRC-30G1000-C-7x-SE 90 180 33.1 6.0 854 774 143 240 33.6 8.1 1122 1015 139 360 34.8 12.5 1630 1467 130 540 36.2 19.5 2350 2095 120 720 37.5 27.0 3029 2671 112 BXRC-30G1000-D-7x-SE 90 175 24.9 4.4 625 567 143 233 25.4 5.9 823 744 139 350 26.0 9.1 1184 1066 130 525 27.4 14.4 1745 1556 121 700 28.4 19.9 2227 1964 112 Performance at Commonly Used Drive Currents Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-30G100C-B-7x-SE 90 135 33.1 4.5 616 559 138 180 33.6 6.1 811 734 134 270 34.8 9.4 1178 1060 125 405 36.2 14.7 1700 1516 116 540 37.5 20.3 2192 1933 108 BXRC-30G100C-D-7x-SE 90 175 24.9 4.4 602 546 138 233 25.4 5.9 793 717 134 350 26.0 9.1 1141 1027 125 525 27.4 14.4 1682 1499 117 700 28.4 19.9 2147 1893 108 BXRC-30H1000-B-7x-SE 97 135 33.1 4.5 579 525 130 180 33.6 6.1 763 690 126 270 34.8 9.4 1107 997 118 405 36.2 14.7 1598 1425 109 540 37.5 20.3 2060 1817 102 BXRC-30H1000-C-7x-SE 97 180 33.1 6.0 773 701 130 240 33.6 8.1 1017 919 126 360 34.8 12.5 1476 1329 118 540 36.2 19.5 2129 1898 109 720 37.5 27.0 2744 2419 102 BXRC-30H1000-D-7x-SE 97 175 24.9 4.4 566 513 130 233 25.4 5.9 745 674 126 350 26.0 9.1 1072 965 118 525 27.4 14.4 1581 1409 110 700 28.4 19.9 2017 1779 101 BXRC-30A1001-B-7x-SE 93 135 33.1 4.5 575 521 129 180 33.6 6.1 756 684 125 270 34.8 9.4 1099 989 117 405 36.2 14.7 1585 1413 108 540 37.5 20.3 2044 1802 101 BXRC-30A1001-C-7x-SE 93 180 33.1 6.0 767 695 129 240 33.6 8.1 1008 912 125 360 34.8 12.5 1465 1318 117 540 36.2 19.5 2112 1882 108 720 37.5 27.0 2722 2400 101 BXRC-30A1001-D-7x-SE 93 175 24.9 4.4 562 509 129 233 25.4 5.9 739 669 125 350 26.0 9.1 1064 958 117 525 27.4 14.4 1568 1398 109 700 28.4 19.9 2001 1765 101 BXRC-35E1000-B-7x-SE 80 135 33.1 4.5 806 731 181 180 33.6 6.1 1061 960 175 270 34.8 9.4 1541 1387 164 405 36.2 14.7 2224 1983 152 540 37.5 20.3 2868 2529 141 Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-35E1000-C-7x-SE 80 180 33.1 6.0 1076 976 181 240 33.6 8.1 1415 1280 175 360 34.8 12.5 2055 1850 164 540 36.2 19.5 2963 2642 152 720 37.5 27.0 3819 3367 141 BXRC-35E1000-D-7x-SE 80 175 24.9 4.4 788 714 181 233 25.4 5.9 1037 938 175 350 26.0 9.1 1493 1344 164 525 27.4 14.4 2201 1962 153 700 28.4 19.9 2808 2476 141 BXRC-35G1000-B-7x-SE 90 135 33.1 4.5 663 601 148 180 33.6 6.1 872 789 144 270 34.8 9.4 1267 1140 135 405 36.2 14.7 1828 1630 125 540 37.5 20.3 2357 2078 116 BXRC-35G1000-C-7x-SE 90 180 33.1 6.0 885 802 148 240 33.6 8.1 1163 1052 144 360 34.8 12.5 1689 1520 135 540 36.2 19.5 2435 2171 125 720 37.5 27.0 3139 2768 116 BXRC-35G1000-D-7x-SE 90 175 24.9 4.4 648 587 148 233 25.4 5.9 853 771 144 350 26.0 9.1 1227 1104 135 525 27.4 14.4 1809 1612 126 700 28.4 19.9 2308 2035 116 BXRC-35A1001-B-73-SE 93 135 33.1 4.5 612 555 137 180 33.6 6.1 805 728 133 270 34.8 9.4 1169 1052 124 405 36.2 14.7 1687 1504 115 540 37.5 20.3 2176 1918 107 BXRC-35A1001-C-73-SE 93 180 33.1 6.0 817 740 137 240 33.6 8.1 1073 971 133 360 34.8 12.5 1559 1403 124 540 36.2 19.5 2248 2004 115 720 37.5 27.0 2897 2555 107 BXRC-35A1001-D-73-SE 93 175 24.9 4.4 598 542 137 233 25.4 5.9 787 712 133 350 26.0 9.1 1133 1019 124 525 27.4 14.4 1669 1488 116 700 28.4 19.9 2130 1878 107 BXRC-40C1001-B-7x-SE 70 135 33.1 4.5 848 769 190 180 33.6 6.1 1116 1010 184 270 34.8 9.4 1621 1459 173 405 36.2 14.7 2339 2085 159 540 37.5 20.3 3016 2659 149 Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-40C1001-C-7x-SE 70 180 33.1 6.0 1132 1026 190 240 33.6 8.1 1488 1346 184 360 34.8 12.5 2162 1945 173 540 36.2 19.5 3116 2778 159 720 37.5 27.0 4017 3542 149 BXRC-40C1001-D-7x-SE 70 175 24.9 4.4 829 751 190 233 25.4 5.9 1091 987 184 350 26.0 9.1 1570 1413 173 525 27.4 14.4 2314 2063 161 700 28.4 19.9 2954 2604 148 BXRC-40E1000-B-7x-SE 80 135 33.1 4.5 811 735 182 180 33.6 6.1 1068 966 176 270 34.8 9.4 1550 1395 165 405 36.2 14.7 2237 1994 152 540 37.5 20.3 2884 2543 142 BXRC-40E1000-C-7x-SE 70 180 33.1 6.0 1083 981 182 240 33.6 8.1 1423 1287 176 360 34.8 12.5 2067 1860 165 540 36.2 19.5 2980 2657 152 720 37.5 27.0 3841 3387 142 BXRC-40E1000-D-7x-SE 70 175 24.9 4.4 793 719 182 233 25.4 5.9 1043 944 176 350 26.0 9.1 1501 1351 165 525 27.4 14.4 2213 1973 154 700 28.4 19.9 2824 2490 142 BXRC-40G1000-B-7x-SE 80 135 33.1 4.5 677 613 152 180 33.6 6.1 891 806 147 270 34.8 9.4 1293 1164 138 405 36.2 14.7 1866 1664 127 540 37.5 20.3 2406 2122 119 BXRC-40G1000-C-7x-SE 80 180 33.1 6.0 903 819 152 240 33.6 8.1 1187 1074 147 360 34.8 12.5 1725 1552 138 540 36.2 19.5 2486 2216 127 720 37.5 27.0 3205 2826 119 BXRC-40G1000-D-7x-SE 80 175 24.9 4.4 661 599 152 233 25.4 5.9 871 787 147 350 26.0 9.1 1253 1127 138 525 27.4 14.4 1846 1646 128 700 28.4 19.9 2356 2078 118 BXRC-40H1000-B-7X-SE 97 135 33.1 4.5 612 555 137 180 33.6 6.1 805 728 133 270 34.8 9.4 1169 1052 124 405 36.2 14.7 1687 1504 115 540 37.5 20.3 2176 1918 107 Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-40H1000-C-7x-SE 97 180 33.1 6.0 817 740 137 240 33.6 8.1 1073 971 133 360 34.8 12.5 1559 1403 124 540 36.2 19.5 2248 2004 115 720 37.5 27.0 2897 2555 107 BXRC-40H1000-D-7x-SE 97 175 24.9 4.4 598 542 137 233 25.4 5.9 787 712 133 350 26.0 9.1 1133 1019 124 525 27.4 14.4 1669 1488 116 700 28.4 19.9 2130 1878 107 BXRC-40A1001-B-7x-SE 93 135 33.1 4.5 663 601 148 180 33.6 6.1 872 789 144 270 34.8 9.4 1267 1140 135 405 36.2 14.7 1828 1630 125 540 37.5 20.3 2357 2078 116 BXRC-40A1001-C-7x-SE 93 180 33.1 6.0 885 802 148 240 33.6 8.1 1163 1052 144 360 34.8 12.5 1689 1520 135 540 36.2 19.5 2435 2171 125 720 37.5 27.0 3139 2768 116 BXRC-40A1001-D-7x-SE 93 175 24.9 4.4 648 587 148 233 25.4 5.9 853 771 144 350 26.0 9.1 1227 1104 135 525 27.4 14.4 1809 1612 126 700 28.4 19.9 2308 2035 116 BXRC-50C1001-B-7x-SE 70 135 33.1 4.5 853 773 191 180 33.6 6.1 1122 1015 185 270 34.8 9.4 1630 1467 173 405 36.2 14.7 2352 2097 160 540 37.5 20.3 3033 2674 150 BXRC-50C1001-C-7x-SE 70 180 33.1 6.0 1138 1032 191 240 33.6 8.1 1496 1353 185 360 34.8 12.5 2173 1956 173 540 36.2 19.5 3133 2793 160 720 37.5 27.0 4039 3561 150 BXRC-50C1001-D-7x-SE 70 175 24.9 4.4 833 755 191 233 25.4 5.9 1097 992 185 350 26.0 9.1 1579 1421 173 525 27.4 14.4 2327 2074 162 700 28.4 19.9 2970 2618 149 BXRC-50E1001-B-7x-SE 80 135 33.1 4.5 820 744 184 180 33.6 6.1 1080 977 178 270 34.8 9.4 1568 1411 167 405 36.2 14.7 2263 2017 154 540 37.5 20.3 2917 2572 144 Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-50E1001-C-7x-SE 80 180 33.1 6.0 1095 993 184 240 33.6 8.1 1439 1302 178 360 34.8 12.5 2091 1882 167 540 36.2 19.5 3014 2687 154 720 37.5 27.0 3885 3426 144 BXRC-50E1001-D-7x-SE 80 175 24.9 4.4 802 727 184 233 25.4 5.9 1055 955 178 350 26.0 9.1 1519 1367 167 525 27.4 14.4 2239 1996 156 700 28.4 19.9 2857 2519 144 BXRC-50G1001-B-7x-SE 90 135 33.1 4.5 709 643 159 180 33.6 6.1 933 844 154 270 34.8 9.4 1355 1220 144 405 36.2 14.7 1956 1744 133 540 37.5 20.3 2522 2223 124 BXRC-50G1001-C-7x-SE 90 180 33.1 6.0 946 858 159 240 33.6 8.1 1244 1125 154 360 34.8 12.5 1807 1626 144 540 36.2 19.5 2606 2323 133 720 37.5 27.0 3358 2961 124 BXRC-50G1001-D-7x-SE 90 175 24.9 4.4 693 628 159 233 25.4 5.9 912 825 154 350 26.0 9.1 1313 1181 144 525 27.4 14.4 1935 1725 135 700 28.4 19.9 2469 2177 124 BXRC-57C1001-B-7x-SE 70 135 33.1 4.5 830 752 186 180 33.6 6.1 1092 988 180 270 34.8 9.4 1586 1427 169 405 36.2 14.7 2288 2040 156 540 37.5 20.3 2950 2601 146 BXRC-57C1001-C-7x-SE 70 180 33.1 6.0 1107 1004 186 240 33.6 8.1 1456 1317 180 360 34.8 12.5 2114 1903 169 540 36.2 19.5 3048 2717 156 720 37.5 27.0 3929 3464 146 BXRC-57C1001-D-7x-SE 70 175 24.9 4.4 811 735 186 233 25.4 5.9 1067 965 180 350 26.0 9.1 1536 1382 169 525 27.4 14.4 2264 2018 158 700 28.4 19.9 2889 2547 145 BXRC-57E1001-B-7x-SE 80 135 33.1 4.5 788 714 177 180 33.6 6.1 1037 938 171 270 34.8 9.4 1506 1355 160 405 36.2 14.7 2173 1937 148 540 37.5 20.3 2802 2470 138 Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRC-57E1001-C-7x-SE 80 180 33.1 6.0 1052 953 177 240 33.6 8.1 1383 1250 171 360 34.8 12.5 2008 1807 160 540 36.2 19.5 2895 2581 148 720 37.5 27.0 3732 3290 138 BXRC-57E1001-D-7x-SE 80 175 24.9 4.4 770 698 177 233 25.4 5.9 1014 917 171 350 26.0 9.1 1459 1313 160 525 27.4 14.4 2150 1917 150 700 28.4 19.9 2744 2419 138 BXRC-65C1001-B-7x-SE 70 135 33.1 4.5 830 752 186 180 33.6 6.1 1092 988 180 270 34.8 9.4 1586 1427 169 405 36.2 14.7 2288 2040 156 540 37.5 20.3 2950 2601 146 BXRC-65C1001-C-7x-SE 70 180 33.1 6.0 1107 1004 186 240 33.6 8.1 1456 1317 180 360 34.8 12.5 2114 1903 169 540 36.2 19.5 3048 2717 156 720 37.5 27.0 3929 3464 146 BXRC-65C1001-D-7x-SE 70 175 24.9 4.4 811 735 186 233 25.4 5.9 1067 965 180 350 26.0 9.1 1536 1382 169 525 27.4 14.4 2264 2018 158 700 28.4 19.9 2889 2547 145 BXRC-65E1001-B-7x-SE 80 135 33.1 4.5 797 723 179 180 33.6 6.1 1049 949 173 270 34.8 9.4 1524 1371 162 405 36.2 14.7 2199 1960 150 540 37.5 20.3 2835 2500 140 BXRC-65E1001-C-7x-SE 80 180 33.1 6.0 1064 965 179 240 33.6 8.1 1399 1265 173 360 34.8 12.5 2032 1828 162 540 36.2 19.5 2929 2611 150 720 37.5 27.0 3775 3329 140 BXRC-65E1001-D-7x-SE 80 175 24.9 4.4 779 706 179 233 25.4 5.9 1026 928 173 350 26.0 9.1 1476 1328 162 525 27.4 14.4 2175 1939 151 700 28.4 19.9 2776 2448 140 Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Electrical Characteristics
Notes for Table 6: 1. Parts are tested in pulsed conditions, Tc = 25°C. Pulse width is 10ms. 2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance. 3. Bridgelux maintains a tester tolerance of ± 0.10V on forward voltage measurements. 4. Typical coefficient of forward voltage tolerance is ± 0.1mV for nominal current. 5. Thermal resistance values are based from test data of a 3000K 80 CRI product. 6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal interface material used during testing is not included in the thermal resistance value. 7. V f min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design and selection over the operating range of the product. 8. This product has been designed and manufactured per IEC 62031:2014. This product has passed dielectric withstand voltage testing at 1160 V. The working voltage designated for the insulation is 80V d.c. The maximum allowable voltage across the array must be determined in the end product application. Table 6: Electrical Characteristics Part Number Drive Current (mA) Forward Voltage Pulsed, Tc = 25ºC (V) 1, 2, 3, 8 Typical Coefficient of Forward Voltage4 ∆Vf/∆Tc (mV/ºC) Typical Thermal Resistance Junction to Case5,6 Rj-c (ºC/W) Driver Selection Voltages7 (V) Minimum Typical Maximum Vf Min. Hot Tc = 105ºC (V) Vf Max. Cold Tc = -40ºC (V) BXRC-xxx100x-B-7x-SE BXRC-xxx100x-C-7x-SE BXRC-xxx100x-D-7x-SE
Table 7: Eye Safety Risk Group (RG) Classifications Notes for Table 7: 1. Eye safety classification for the use of Bridgelux Vero SE Series LED arrays is in accordance with specification IEC/TR 62778: Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires. 2. For products classified as RG2 at 4000K, Ethr= 1847.5 lx. 3. For products classified as RG2 at 5000K Ethr= 1315.8 lx. 4. For products classified as RG2 at 6500K, Ethr= 1124.5 lx. 5. Please contact your Bridgelux sales representative for Ethr values at specific drive currents and CCTs not listed. Part Number Drive Current 5 (mA) CCT1,5 2700K/3000K 4000K2 5000K3 6500K4 BXRC-xxx100x-B-7x-SE
270 RG1 RG1 RG1 RG1
405 RG1 RG1 RG1 RG2
540 RG1 RG1 RG2 RG2
360 RG1 RG1 RG1 RG2
720 RG1 RG2 RG2 RG2
350 RG1 RG1 RG1 RG1
525 RG1 RG1 RG1 RG2
700 RG1 RG1 RG2 RG2
LED Junction Temperature (Tj) 150°C Storage Temperature -40°C to +105°C Operating Case Temperature1 (Tc) 105°C BXRC-xxx100x-B-7x-SE BXRC-xxx100x-C-7x-SE BXRC-xxx100x-D-7x-SE Maximum Drive Current3 540mA 720mA 700mA Maximum Peak Pulsed Drive Current4 770mA 1030mA 1000mA Maximum Reverse Voltage5 -60V -60V -45V Table 8: Maximum Ratings Notes for Table 8: 1. For IEC 62717 requirement, please consult your Bridgelux sales representative. 2. Refer to Bridgelux Application Note AN120: Assembly Considerations for Bridgelux Vero SE LED Arrays. 3. Arrays may be driven at higher currents however lumen maintenance may be reduced. 4. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed current specified. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures. 5. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating provided for reference only.
Figure 21: Drawing for Vero SE 10 LED Array Notes for Figure 21: 1. Drawings are not to scale. 2. Dimensions are in mm. 3. Unless otherwise specified, tolerances are ± 0.15mm. 4. Mounting holes (2X) are for M3 screws. 5. Bridgelux recommends two tapped holes for mounting screws with 18.9 ± 0.10mm center-to-center spacing. 6. Screws with flat shoulders (pan, dome, button, round, truss, mushroom) provide optimal torque control. Do NOT use flat, countersink, or raised head screws. 7. The optical center of the LED Array is nominally defined by the mechanical center of the array to a tolerance of ± 0.2mm. 8. Bridgelux maintains a flatness of 0.10mm across the mounting surface of the array.
Figure 22: Warm and Neutral White Test Bins in xy Color Space Color Binning Information Bin Code1 2000K 2700K 3000K1 3500K1 4000K1 ANSI Bin (for reference only) - (2580K - 2870K) (2870K - 3220K) (3220K - 3710K) (3710K - 4260K) 73 (3 SDCM) - (2651K - 2794K) (2968K - 3136K) (3369K - 3586K) (3851K - 4130K) 72 (2 SDCM) - (2674K - 2769K) (2995K - 3107K) (3404K - 3548K) (3895K - 4081K) Table 9: Warm and Neutral White xy Bin Coordinates and Associated Typical CCT Bin Code 5000K 5700K 6500K ANSI Bin (for reference only) (4745K - 5311K) (5312K - 6022K) (6022K - 7042K) 74 (4 SDCM) (4801K - 5282K) (5395K- 5970K) (6200K - 6910K) 73 (3 SDCM) (4835K - 5215K) (5460K- 5891K) (6279K -6811K) Table 10: Cool White xy Bin Coordinates and Associated Typical CCT (product is hot targeted to Tc = 85°C) Note: Pulsed Test Conditions, Tc = 25°C Notes for Table 9: 1. Color Binning information excludes Decor Series Class A products. Please contact your Bridgelux Sales Representative for more information. 2. Center Point for Decor Series Showcase. 3. Bridgelux maintains a tolerance of +/- 0.007 on x and y color coordinates in the CIE 1931 color Space. Figure 23: Cool White Test Bins in xy Color Space Note: Pulsed Test Conditions, Tc = 25°C 0.34 0.36 0.38 0.4 0.42 0.44 Y X
3 SDCM
2 SDCM
0.3 0.31 0.32 0.33 0.34 0.35 0.36 0.37 0.38 0.39 Y X
4 SDCM
Note for Table 10: 1. Bridgelux maintains a tolerance of +/- 0.007 on x and y color coordinates in the CIE 1931 color Space.
Figure 24: Drawing for Vero SE 10 Packaging Tray Notes for Figure 24: 1. Dimensions are in millimeters. 2. Drawings are not to scale.
Bridgelux has developed a comprehensive set of application notes and design resources to assist customers in successfully designing with the Vero product family of LED array products. For all available application notes visit www.bridgelux.com. Optical Source Models Optical source models and ray set files are available for all Bridgelux products. For a list of available formats, visit www.bridgelux.com. MINOR PRODUCT CHANGE POLICY The rigorous qualification testing on products offered by Bridgelux provides performance assurance. Slight cosmetic changes that do not affect form, fit, or function may occur as Bridgelux continues product optimization. CAUTION: CHEMICAL EXPOSURE HAZARD Exposure to some chemicals commonly used in luminaire manufacturing and assembly can cause damage to the LED array. Please consult Bridgelux CAUTION: RISK OF BURN Do not touch the Vero LED array during operation. Allow the array to cool for a sufficient period of time before handling. The Vero LED array may reach elevated temperatures such that could burn skin when touched. 3D CAD Models Three dimensional CAD models depicting the product outline of all Bridgelux Vero LED arrays are available in both IGS and STEP formats. Please contact your Bridgelux sales representative for assistance. LM80 LM80 testing has been completed and the LM80 report is now available. Please contact your Bridgelux sales representative for LM-80 report. CAUTION CONTACT WITH LIGHT EMITTING SURFACE (LES) Avoid any contact with the LES. Do not touch the LES of the LED array or apply stress to the LES (yellow phosphor resin area). Contact may cause damage to the LED array. Optics and reflectors must not be mounted in contact with the LES (yellow phosphor resin area). Optical devices may be mounted on the top surface of the plastic housing of the Vero LED array. Use the mechanical features of the LED array housing, edges and/or mounting holes to locate and secure optical devices as needed. STANDARD TEST CONDITIONS Unless otherwise stated, array testing is performed at the nominal drive current.
About Bridgelux: Bridging Light and Life™ © 2023 Bridgelux, Inc. All rights reserved. Product specifications are subject to change without notice. Bridgelux, the Bridgelux stylized logo design, Vero, V Series, V Series HD and are registered trademarks, and Decor Series is a trademark of Bridgelux, Inc. All other trademarks are the property of their respective owners. Bridgelux Vero SE 10 Array Series Product Data Sheet DS120 Rev. Q (07/2023)
46410 Fremont Boulevard
Fremont, CA 94538 U.S.A. Tel (925) 583-8400 www.bridgelux.com At Bridgelux, we help companies, industries and people experience the power and possibility of light. Since 2002, we’ve designed LED solutions that are high performing, energy efficient, cost effective and easy to integrate. Our focus is on light’s impact on human behavior, delivering products that create better environments, experiences and returns—both experiential and financial. And our patented technology drives new platforms for commercial and industrial luminaires. For more information about the company, please visit bridgelux.com twitter.com/Bridgelux facebook.com/Bridgelux youtube.com/user/Bridgelux linkedin.com/company/bridgelux-inc-_2 WeChat ID: BridgeluxInChina