The V Series™ LED Array products deliver high quality light in a compact and cost-effective solid-state lighting package. These chip on board (CoB) arrays can be efficiently driven at twice the nominal drive current, enabling design flexibility not previously possible. This high flux density light source is designed to support a wide range of high quality, low cost directional luminaires and replacement lamps for commercial and residential applications. The V10 LED array is available in a variety of electrical, CCT and CRI combinations providing substantial design flexibility and energy efficiencies. Lighting system designs incorporating these LED arrays deliver increased system level efficacy and longer service life. Typical applications include, replacement lamps, and task, accent, spot, track, wide area, security, wall pack and down lights. Bridgelux Décor Series is our state of the art color line designed specifically for premium applications, producing unmatched LED light quality with brilliant color-rendering options and offer pleasing and inspiring lighting palettes. Bridgelux Décor Series color points are available on Vero® SE Series, Vero® Series, V Series™ and H Series™. Décor Series Class A is based on human response testing, providing color points with a combined GAI and CRI metric. Décor Series™ Ultra products provide a high CRI of 97 and a minimum R9 value of 93, which emphasizes the reds and color tones to which the human eye is most receptive - perfect for the most luxurious retail shops and world renowned museums. Décor Series Ultra is designed as a replacement for halogen. Décor Series™ Street and Landmark is designed to be a direct replacement for high pressure sodium lamps. Décor Series™ Showcase is the optimal solution for replacing ceramic metal halide lamps, incorporating the same pure white light with enhanced spectrum coverage and higher efficacy. V Series

Features

  • Efficacy of 167 lm/W typical
  • Compact high flux density light source
  • Uniform high quality illumination
  • Minimum 65, 70, 80 and 90 and 95 CRI options
  • Streamlined thermal path
  • ENERGY STAR® / ANSI compliant color binning structure with 2, 3 and 4 SDCM options
  • More energy efficient than incandescent, halogen and fluorescent lamps
  • Low voltage DC operation
  • Instant light with unlimited dimming
  • V f bin code backside marking Benefits
  • Enhanced optical control
  • Clean white light without pixilation
  • High quality true color reproduction
  • Significantly reduced thermal resistance and increased operating temperatures
  • Uniform consistent white light
  • Lower operating costs
  • Easy to use with daylight and motion detectors to enable increased energy savings
  • Reduced maintenance costs
  • Environmentally friendly, no disposal issue

The part number designation for Bridgelux V Series LED arrays is explained as follows: 1 2 3 4 5 6 7 8 9 10 11 – 12 – 13 14 Product Family CCT Bin Options 2 = 2 SDCM 3 = 3 SDCM 4 = 4 SDCM CRI B = 63 CRI typ. C = 70 CRI min. E = 80 CRI min. G = 90 CRI min. H = 97 CRI typ. A = Class A Array Configuration 20 = 2,000K 27 = 2,700K 30 = 3,000K 35 = 3,500K 40 = 4,000K 50 = 5,000K 57 = 5,700K 65 = 6,500K BXRE – 30 E 100 0 – C – 7 3 Color Targeting Designator 0 = Cold Targeted 1 = Hot Targeted C = Décor Series Showcase Target Gen. 7Nominal CCT Flux Indicator 100x = 1000 lm Bridgelux arrays are fully engineered devices that provide consistent thermal and optical performance on an engineered mechanical platform. The V Series arrays are the most compact chip-on-board devices across all of Bridgelux’s LED Array products. The arrays incorporate several features to simplify design integration and assembly. Please visit www.bridgelux.com for more information on the V Series family of products. Fully engineered substrate for consistent thermal, mechanical and optical properties Yellow phosphor Light Emitting Surface (LES) Note: Part number and lot codes are scribed on back of array Polarity symbols Solder Pads White ring around LES Case Temperature (Tc) Measurement Point Designed to comply with global safety standards for creepage and clearance distances

The following product configurations are available: Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRE-20B1001-B-7x 2000 65 270 1439 1266 34.8 9.5 152 BXRE-27E1000-B-7x 2700 80 270 1458 1283 34.8 9.4 155 BXRE-27E1000-C-7x 2700 80 360 1944 1711 34.8 12.5 155 BXRE-27G10H0-B-7x 2700 90 270 1249 1099 34.8 9.4 133 BXRE-27G10H0-C-7x 2700 90 360 1665 1465 34.8 12.5 133 BXRE-27G1000-B-7x 2700 90 270 1203 1059 34.8 9.4 128 BXRE-27G1000-C-7x 2700 90 360 1604 1412 34.8 12.5 128 BXRE-27H1000-B-7x 2700 97 270 1066 938 34.8 9.4 113 BXRE-27H1000-C-7x 2700 97 360 1422 1251 34.8 12.5 113 BXRE-30C1001-B-7x 3000 70 270 1622 1428 34.8 9.4 173 BXRE-30C1001-C-7x 3000 70 360 2163 1904 34.8 12.5 173 BXRE-30E1000-B-7x 3000 80 270 1549 1363 34.8 9.4 165 BXRE-30E1000-C-7x 3000 80 360 2066 1818 34.8 12.5 165 BXRE-30G10H0-B-7x 3000 90 270 1312 1155 34.8 9.4 140 BXRE-30G10H0-C-7x 3000 90 360 1750 1540 34.8 12.5 140 BXRE-30G1000-B-7x 3000 90 270 1258 1107 34.8 9.4 134 BXRE-30G1000-C-7x 3000 90 360 1677 1476 34.8 12.5 134 BXRE-30G100C-B-7x 3000 90 270 1212 1067 34.8 9.4 129 BXRE-30G100C-C-7x 3000 90 360 1616 1422 34.8 12.5 129 BXRE-30A1001-B-7x8,9 3000 93 270 1130 995 34.8 9.4 120 BXRE-30A1001-C-7x8,9 3000 93 360 1507 1326 34.8 12.5 120 BXRE-30H1000-B-7x 3000 97 270 1139 1003 34.8 9.4 121 BXRE-30H1000-C-7x 3000 97 360 1519 1337 34.8 12.5 121 BXRE-35E1000-B-7x 3500 80 270 1586 1396 34.8 9.4 169 BXRE-35E1000-C-7x 3500 80 360 2114 1861 34.8 12.5 169 BXRE-35G1000-B-7x 3500 90 270 1303 1147 34.8 9.4 139 BXRE-35G1000-C-7x 3500 90 360 1738 1529 34.8 12.5 139 BXRE-35A1001-B-7x8,9 3500 93 270 1203 1059 34.8 9.4 128 BXRE-35A1001-C-7x8,9 3500 93 360 1604 1412 34.8 12.5 128 BXRE-35H1000-B-7x 3500 97 270 1175 1034 34.8 9.4 125 BXRE-35H1000-C-7x 3000 97 360 1566 1378 34.8 12.5 125 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are typical for Decor Series Ultra, Décor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, Minimum R9 value is 60 for 90 CRI products on 2700K/3000K/3500K and 4000K, it is 50 on 5000K/5700K and 6500K. But for the CRI90 H0 products (higher efficiency CRI90 version), minimum R9 value is 55 on 2700K/3000K/3500K and 4000K. Minimum R9 value for 97 CRI products is 93 on 2700K and 3000K,and it is 85 on 3500K /4000K/5000K and 5700K. Bridgelux maintains a ± 3 tolerance on R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance.

Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C)(Continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRE-40C1001-B-7x 4000 70 270 1668 1468 34.8 9.4 178 BXRE-40C1001-C-7x 4000 70 360 2224 1957 34.8 12.5 178 BXRE-40E1000-B-7x 4000 80 270 1595 1404 34.8 9.4 170 BXRE-40E1000-C-7x 4000 80 360 2127 1871 34.8 12.5 170 BXRE-40G1000-B-7x 4000 90 270 1331 1171 34.8 9.4 142 BXRE-40G1000-C-7x 4000 90 360 1774 1561 34.8 12.5 142 BXRE-40H1000-B-7x 3500 97 270 1203 1059 34.8 9.4 128 BXRE-40H1000-C-7x 3000 97 360 1604 1412 34.8 12.5 128 BXRE-50C1001-B-7x 5000 70 270 1677 1476 34.8 9.4 178 BXRE-50C1001-C-7x 5000 70 360 2236 1968 34.8 12.5 178 BXRE-50E1001-B-7x 5000 80 270 1613 1420 34.8 9.4 172 BXRE-50E1001-C-7x 5000 80 360 2151 1893 34.8 12.5 172 BXRE-50G1001-B-7x 5000 90 270 1394 1227 34.8 9.4 148 BXRE-50G1001-C-7x 5000 90 360 1859 1636 34.8 12.5 148 BXRE-57C1001-B-7x 5700 70 270 1631 1436 34.8 9.4 174 BXRE-57C1001-C-7x 5700 70 360 2175 1914 34.8 12.5 174 BXRE-57E1001-B-7x 5700 80 270 1549 1363 34.8 9.4 165 BXRE-57E1001-C-7x 5700 80 360 2066 1818 34.8 12.5 165 BXRE-65C1001-B-7x 6500 70 270 1631 1436 34.8 9.4 174 BXRE-65C1001-C-7x 6500 70 360 2175 1914 34.8 12.5 174 BXRE-65E1001-B-7x 6500 80 270 1568 1380 34.8 9.4 167 BXRE-65E1001-C-7x 6500 80 360 2090 1839 34.8 12.5 167 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are typical for Decor Series Ultra, Décor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, Minimum R9 value is 60 for 90 CRI products on 2700K/3000K/3500K and 4000K, it is 50 on 5000K/5700K and 6500K. But for the CRI90 H0 products (higher efficiency CRI90 version), minimum R9 value is 55 on 2700K/3000K/3500K and 4000K. Minimum R9 value for 97 CRI products is 93 on 2700K and 3000K,and it is 85 on 3500K /4000K/5000K and 5700K. Bridgelux maintains a ± 3 tolerance on R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance.

Table 2: Selection Guide, Stabilized DC Performance (Tc = 70°C) 7,8 Part Number Nominal CCT1 (K) GAI2 CRI3 Nominal Drive Current4 (mA) Typical DC Flux5,6 Tc = 70ºC (lm) Minimum DC Flux6,9 Tc = 70ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRE-30A1001-B-7x 3000 80 93 270 1051 925 34.3 9.3 113 BXRE-30A1001-C-7x 3000 80 93 360 1401 1233 34.3 12.3 113 BXRE-35A1001-B-7x 3500 80 93 270 1119 985 34.3 9.3 121 BXRE-35A1001-C-7x 3500 80 93 360 1492 1313 34.3 12.3 121 Notes for Table 2: 1. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 2. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance. 3. All CRI values are measured at Tj = Tc = 25°C. CRI Values are specified as typical. 4. Drive current is referred to as nominal drive current. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 8. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at specified temperature. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 9. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. Product Selection Guide

Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRE-20B1001-B-7x 2000 65 270 1295 1140 33.8 9.1 142 BXRE-27E1000-B-7x 2700 80 270 1312 1155 33.8 9.1 144 BXRE-27E1000-C-7x 2700 80 360 1750 1540 33.8 12.2 144 BXRE-27G10H0-B-7x 2700 90 270 1124 989 33.8 9.1 123 BXRE-27G10H0-C-7x 2700 90 360 1498 1319 33.8 12.2 123 BXRE-27G1000-B-7x 2700 90 270 1083 953 33.8 9.1 119 BXRE-27G1000-C-7x 2700 90 360 1444 1270 33.8 12.2 119 BXRE-27H1000-B-7x 2700 97 270 960 845 33.8 9.1 105 BXRE-27H1000-C-7x 2700 90 360 1280 1126 33.8 12.2 105 BXRE-30C1001-B-7x 3000 70 270 1460 1285 33.8 9.1 160 BXRE-30C1001-C-7x 3000 70 360 1947 1713 33.8 12.2 160 BXRE-30E1000-B-7x 3000 80 270 1394 1227 33.8 9.1 153 BXRE-30E1000-C-7x 3000 80 360 1859 1636 33.8 12.2 153 BXRE-30G10H0-B-7x 3000 90 270 1181 1039 33.8 9.1 129 BXRE-30G10H0-C-7x 3000 90 360 1575 1386 33.8 12.2 129 BXRE-30G1000-B-7x 3000 90 270 1132 996 33.8 9.1 124 BXRE-30G1000-C-7x 3000 90 360 1509 1328 33.8 12.2 124 BXRE-30G100C-B-7x 3000 90 270 1091 960 33.8 9.1 120 BXRE-30G100C-C-7x 3000 90 360 1455 1280 33.8 12.2 120 BXRE-30A1001-B-7x7,8 3000 93 270 1017 895 33.8 9.1 111 BXRE-30A1001-C-7x7,8 3000 93 360 1356 1193 33.8 12.2 111 BXRE-30H1000-B-7x 3000 97 270 1025 902 33.8 9.1 112 BXRE-30H1000-C-7x 3000 97 360 1367 1203 33.8 12.2 112 BXRE-35E1000-B-7x 3500 80 270 1427 1256 33.8 9.1 156 BXRE-35E1000-C-7x 3500 80 360 1903 1675 33.8 12.2 156 BXRE-35G1000-B-7x 3500 90 270 1173 1032 33.8 9.1 128 BXRE-35G1000-C-7x 3500 90 360 1564 1376 33.8 12.2 128 BXRE-35A1001-B-7x7,8 3500 93 270 1083 953 33.8 9.1 119 BXRE-35A1001-C-7x7,8 3500 93 360 1444 1270 33.8 12.2 119 BXRE-35H1000-B-7x 3000 97 270 1057 930 33.8 9.1 116 BXRE-35H1000-C-7x 3000 97 360 1409 1240 33.8 12.2 116 Notes for Table 3: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Décor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, Minimum R9 value is 60 for 90 CRI products on 2700K/3000K/3500K and 4000K, it is 50 on 5000K/5700K and 6500K. But for the CRI90 H0 products (higher efficiency CRI90 version), minimum R9 value is 55 on 2700K/3000K/3500K and 4000K. Minimum R9 value for 97 CRI products is 93 on 2700K and 3000K,and it is 85 on 3500K /4000K/5000K and 5700K. Bridgelux maintains a ± 3 tolerance on R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance.

Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5(Continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRE-40C1001-B-7x 4000 70 270 1501 1321 33.8 9.1 164 BXRE-40C1001-C-7x 4000 70 360 2001 1761 33.8 12.2 164 BXRE-40E1000-B-7x 4000 80 270 1435 1263 33.8 9.1 157 BXRE-40E1000-C-7x 4000 80 360 1914 1684 33.8 12.2 157 BXRE-40G1000-B-7x 4000 90 270 1198 1054 33.8 9.1 131 BXRE-40G1000-C-7x 4000 90 360 1597 1405 33.8 12.2 131 BXRE-40H1000-B-7x 3000 97 270 1083 953 33.8 9.1 119 BXRE-40H1000-C-7x 3000 97 360 1444 1270 33.8 12.2 119 BXRE-50C1001-B-7x 5000 70 270 1509 1328 33.8 9.1 165 BXRE-50C1001-C-7x 5000 70 360 2012 1771 33.8 12.2 165 BXRE-50E1001-B-7x 5000 80 270 1452 1278 33.8 9.1 159 BXRE-50E1001-C-7x 5000 80 360 1936 1704 33.8 12.2 159 BXRE-50G1001-B-7x 5000 90 270 1255 1104 33.8 9.1 137 BXRE-50G1001-C-7x 5000 90 360 1673 1473 33.8 12.2 137 BXRE-57C1001-B-7x 5700 70 270 1468 1292 33.8 9.1 161 BXRE-57C1001-C-7x 5700 70 360 1958 1723 33.8 12.2 161 BXRE-57E1001-B-7x 5700 80 270 1394 1227 33.8 9.1 153 BXRE-57E1001-C-7x 5700 80 360 1859 1636 33.8 12.2 153 BXRE-65C1001-B-7x 6500 70 270 1468 1292 33.8 9.1 161 BXRE-65C1001-C-7x 6500 70 360 1958 1723 33.8 12.2 161 BXRE-65E1001-B-7x 6500 80 270 1411 1242 33.8 9.1 154 BXRE-65E1001-C-7x 6500 80 360 1881 1655 33.8 12.2 154 Notes for Table 3: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Décor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, Minimum R9 value is 60 for 90 CRI products on 2700K/3000K/3500K and 4000K, it is 50 on 5000K/5700K and 6500K. But for the CRI90 H0 products (higher efficiency CRI90 version), minimum R9 value is 55 on 2700K/3000K/3500K and 4000K. Minimum R9 value for 97 CRI products is 93 on 2700K and 3000K,and it is 85 on 3500K /4000K/5000K and 5700K. Bridgelux maintains a ± 3 tolerance on R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance.

European Product Registry for Energy Labeling The European Product Registry for Energy Labeling (EPREL) is defined in the EU Regulation 2017/1369 to provide import- ant energy efficiency information to consumers. Together with Energy Labeling Regulation ELR (EU) 2019/2015 which was amended by regulation (EU) 2021/340 for energy labelling of light sources, manufacturers are required to declare an ener- gy class based on key technical specifications from each of their product and register it in an open data base managed by EPREL It is now a legal requirement for a vendor of light sources to upload information about their products into the EPREL database before placing these products on the market in the EU. Table 4 below provides a list of part numbers that are in compliance with ELR and are currently listed in the EPREL data- base. At Bridgelux, we are fully committed to supplying products that are compliant with pertinent laws, rules, and obligation imposed by relevant government bodies including the European Energy Labeling regulation. Customers can use these products with full confidence for any projects that fall under the ELR. Table 4: Part numbers registered in European Product Registry for Energy Labeling PART NUMBER1 CCT (K) CRI Current2 (mA) Vf (V) Useful flux3 (Φuse) at 85C (lm) Pow- er (W) Efficacy (lm/W) Energy efficiency class4 Regis- tration No URL to Product Information Sheet in EPREL Database Notes for Table 4: 1. All device listed here must be disposed as e-waste upon its end of life according to local country guideline in each country. 2. For information on performance values at alternative drive conditions. please refer to the Product Selection Guide, Absolute Maximum Rating Table and Performance Curves in this data sheet. 3. For a definition of useful luminous flux (ΦΦuse), please see the ELR regulations at https:/ /tinyurl.com/4b6zvt4m. 4. EPREL requires an arrow symbol containing the letter of the energy efficiency class to be displayed. on technical promotional material. Refer to this energy efficiency class column for specific energy efficiency class on each part number.

European Product Registry for Energy Labeling Table 4: Part numbers registered in European Product Registry for Energy Labeling (Continued) PART NUMBER1 CCT (K) CRI Current2 (mA) Vf (V) Useful flux3 (Φuse) at 85C (lm) Pow- er (W) Efficacy (lm/W) Energy efficiency class4 Regis- tration No URL to Product Information Sheet in EPREL Database Notes for Table 4: 1. All device listed here must be disposed as e-waste upon its end of life according to local country guideline in each country. 2. For information on performance values at alternative drive conditions. please refer to the Product Selection Guide, Absolute Maximum Rating Table and Performance Curves in this data sheet. 3. For a definition of useful luminous flux (ΦΦuse), please see the ELR regulations at https:/ /tinyurl.com/4b6zvt4m. 4. EPREL requires an arrow symbol containing the letter of the energy efficiency class to be displayed. on technical promotional material. Refer to this energy efficiency class column for specific energy efficiency class on each part number.

Performance at Commonly Used Drive Currents V Series LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. V Series LED Arrays may also be driven at other drive currents dependent on specific application design requirements. The performance at any drive current can be derived from the current vs. voltage characteristics shown in Figures 1 & 2 and the flux vs. current characteristics shown in Figures 3 & 4. The performance at commonly used drive currents is summarized in Table 5. Table 5: Product Performance at Commonly Used Drive Currents Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRE-20B1001-B-7x 65 135 33.2 4.5 767 689 171 180 34.0 6.1 1006 902 164 270 34.8 9.4 1439 1295 153 405 35.6 14.4 2111 1878 146 540 36.1 19.5 2705 2394 139 BXRE-27E1000-B-7x 80 135 33.2 4.5 777 698 173 180 34.0 6.1 1019 914 166 270 34.8 9.4 1458 1312 155 405 35.6 14.4 2139 1903 148 540 36.1 19.5 2741 2426 140 BXRE-27E1000-C-7x 80 180 33.2 6.0 1034 922 173 240 34.0 8.2 1354 1203 166 360 34.8 12.5 1944 1750 155 540 35.6 19.2 2831 2460 147 720 36.1 26.0 3617 3096 139 BXRE-27G10H0-B-7x 90 135 33.2 4.5 665 598 148 180 34.0 6.1 872 783 143 270 34.8 9.4 1249 1124 133 405 35.6 14.4 1832 1630 127 540 36.1 19.5 2347 2077 120 BXRE-27G10H0-C-7x 90 180 33.2 6.0 885 790 148 240 34.0 8.2 1160 1030 142 360 34.8 12.5 1665 1498 133 540 35.6 19.2 2424 2106 126 720 36.1 26.0 3097 2651 119 BXRE-27G1000-B-7x 90 135 33.2 4.5 641 576 143 180 34.0 6.1 841 754 137 270 34.8 9.4 1203 1083 128 405 35.6 14.4 1765 1570 122 540 36.1 19.5 2261 2001 116 BXRE-27G1000-C-7x 90 180 33.2 6.0 853 761 143 240 34.0 8.2 1117 993 137 360 34.8 12.5 1604 1444 128 540 35.6 19.2 2336 2029 121 720 36.1 26.0 2984 2554 115 BXRE-27H1000-B-7x 97 135 33.2 4.5 568 511 127 180 34.0 6.1 745 668 122 270 34.8 9.4 1066 960 113 405 35.6 14.4 1564 1392 108 540 36.1 19.5 2004 1774 103 Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRE-27H1000-C-7x 97 180 33.2 6.0 756 675 126 240 34.0 8.2 990 880 121 360 34.8 12.5 1422 1509 113 540 35.6 19.2 2070 1799 108 720 36.1 26.0 2645 2264 102 BXRE-30C1001-B-7x 70 135 33.2 4.5 864 777 193 180 34.0 6.1 1134 1017 185 270 34.8 9.4 1622 1460 173 405 35.6 14.4 2380 2117 165 540 36.1 19.5 3049 2699 156 BXRE-30C1001-C-7x 70 180 33.2 6.0 1150 1026 192 240 34.0 8.2 1507 1338 185 360 34.8 12.5 2163 1947 173 540 35.6 19.2 3150 2736 164 720 36.1 26.0 4023 3444 155 BXRE-30E1000-B-7x 80 135 33.2 4.5 826 742 184 180 34.0 6.1 1083 971 177 270 34.8 9.4 1549 1394 165 405 35.6 14.4 2273 2022 157 540 36.1 19.5 2912 2577 149 BXRE-30E1000-C-7x 80 180 33.2 6.0 1098 980 184 240 34.0 8.2 1439 1278 176 360 34.8 12.5 2066 1859 165 540 35.6 19.2 3008 2613 156 720 36.1 26.0 3843 3289 148 BXRE-30G10H0-B-7x 90 135 33.2 4.5 699 628 156 180 34.0 6.1 917 823 150 270 34.8 9.4 1312 1181 140 405 35.6 14.4 1925 1713 133 540 36.1 19.5 2467 2183 126 BXRE-30G10H0-C-7x 90 180 33.2 6.0 930 830 156 240 34.0 8.2 1219 1083 149 360 34.8 12.5 1750 1575 140 540 35.6 19.2 2548 2214 132 720 36.1 26.0 3255 2786 125 BXRE-30G1000-B-7x 90 135 33.2 4.5 670 602 149 180 34.0 6.1 879 788 144 270 34.8 9.4 1258 1132 134 405 35.6 14.4 1845 1641 128 540 36.1 19.5 2364 2092 121 BXRE-30G1000-C-7x 90 180 33.2 6.0 892 796 149 240 34.0 8.2 1168 1038 143 360 34.8 12.5 1677 1509 134 540 35.6 19.2 2442 2121 127 720 36.1 26.0 3119 2670 120 Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRE-30G100C-B-7x 90 135 33.2 4.5 646 580 144 180 34.0 6.1 847 760 138 270 34.8 9.4 1212 1091 129 405 35.6 14.4 1778 1582 123 540 36.1 19.5 2278 2016 117 BXRE-30G100C-C-7x 90 180 33.2 6.0 859 767 144 240 34.0 8.2 1126 1000 138 360 34.8 12.5 1616 1455 129 540 35.6 19.2 2353 2045 122 720 36.1 26.0 3006 2573 116 BXRE-30A1001-B-7x 93 135 33.2 4.5 602 541 134 180 34.0 6.1 790 708 129 270 34.8 9.4 1130 1017 120 405 35.6 14.4 1658 1475 115 540 36.1 19.5 2124 1880 109 BXRE-30A1001-C-7x 93 180 33.2 6.0 801 715 134 240 34.0 8.2 1050 932 129 360 34.8 12.5 1507 1356 120 540 35.6 19.2 2194 1906 114 720 36.1 26.0 2803 2399 108 BXRE-30H1000-B-7x 97 135 33.2 4.5 607 546 135 180 34.0 6.1 796 714 130 270 34.8 9.4 1139 1025 121 405 35.6 14.4 1671 1487 116 540 36.1 19.5 2141 1895 110 BXRE-30H1000-C-7x 97 180 33.2 6.0 808 721 135 240 34.0 8.2 1058 940 130 360 34.8 12.5 1519 1409 121 540 35.6 19.2 2212 1922 115 720 36.1 26.0 2825 2419 109 BXRE-35E1000-B-7x 80 135 33.2 4.5 845 759 188 180 34.0 6.1 1108 994 181 270 34.8 9.4 1586 1427 169 405 35.6 14.4 2327 2070 161 540 36.1 19.5 2981 2638 153 BXRE-35E1000-C-7x 80 180 33.2 6.0 1124 1003 188 240 34.0 8.2 1473 1308 180 360 34.8 12.5 2114 1903 169 540 35.6 19.2 3079 2675 160 720 36.1 26.0 3933 3367 151 BXRE-35G1000-B-7x 90 135 33.2 4.5 695 624 155 180 34.0 6.1 911 817 149 270 34.8 9.4 1303 1173 139 405 35.6 14.4 1912 1701 132 540 36.1 19.5 2450 2168 126 Performance at Commonly Used Drive Currents Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRE-35G1000-C-7x 90 180 33.2 6.0 924 824 155 240 34.0 8.2 1210 1075 148 360 34.8 12.5 1738 1564 139 540 35.6 19.2 2530 2198 131 720 36.1 26.0 3232 2767 124 BXRE-35A1001-B-7x 93 135 33.2 4.5 641 576 143 180 34.0 6.1 841 754 137 270 34.8 9.4 1203 1083 128 405 35.6 14.4 1765 1570 122 540 36.1 19.5 2261 2001 116 BXRE-35A1001-C-7x 93 180 33.2 6.0 853 761 143 240 34.0 8.2 1117 993 137 360 34.8 12.5 1604 1444 128 540 35.6 19.2 2336 2029 121 720 36.1 26.0 2984 2554 115 BXRE-35H1000-B-7x 97 135 33.2 4.5 626 562 140 180 34.0 6.1 821 736 134 270 34.8 9.4 1175 1057 125 405 35.6 14.4 1723 1533 119 540 36.1 19.5 2207 1954 113 BXRE-35H1000-C-7x 97 180 33.2 6.0 833 743 139 240 34.0 8.2 1091 969 134 360 34.8 12.5 1566 1409 125 540 35.6 19.2 2280 1981 118 720 36.1 26.0 2913 2493 112 BXRE-40C1001-B-7x 70 135 33.2 4.5 889 799 198 180 34.0 6.1 1165 1045 190 270 34.8 9.4 1668 1501 178 405 35.6 14.4 2447 2177 170 540 36.1 19.5 3135 2775 161 BXRE-40C1001-C-7x 70 180 33.2 6.0 1182 1055 198 240 34.0 8.2 1549 1376 190 360 34.8 12.5 2224 2001 178 540 35.6 19.2 3238 2813 168 720 36.1 26.0 4136 3541 159 BXRE-40E1000-B-7x 80 135 33.2 4.5 850 764 190 180 34.0 6.1 1114 1000 182 270 34.8 9.4 1595 1435 170 405 35.6 14.4 2340 2082 162 540 36.1 19.5 2998 2653 154 BXRE-40E1000-C-7x 80 180 33.2 6.0 1131 1009 189 240 34.0 8.2 1481 1316 181 360 34.8 12.5 2127 1914 170 540 35.6 19.2 3097 2690 161 720 36.1 26.0 3956 3386 152 Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRE-40G1000-B-7x 90 135 33.2 4.5 709 637 158 180 34.0 6.1 930 834 152 270 34.8 9.4 1331 1198 142 405 35.6 14.4 1952 1737 135 540 36.1 19.5 2501 2214 128 BXRE-40G1000-C-7x 90 180 33.2 6.0 943 842 158 240 34.0 8.2 1236 1098 151 360 34.8 12.5 1774 1597 142 540 35.6 19.2 2584 2244 134 720 36.1 26.0 3300 2825 127 BXRE-40H1000-B-7x 97 135 33.2 4.5 641 576 143 180 34.0 6.1 841 754 137 270 34.8 9.4 1203 1083 128 405 35.6 14.4 1765 1570 122 540 36.1 19.5 2261 2001 116 BXRE-40H1000-C-7x 97 180 33.2 6.0 853 761 143 240 34.0 8.2 1117 993 137 360 34.8 12.5 1604 1444 128 540 35.6 19.2 2336 2029 121 720 36.1 26.0 2984 2554 115 BXRE-50C1001-B-7x 70 135 33.2 4.5 894 803 199 180 34.0 6.1 1172 1051 191 270 34.8 9.4 1677 1509 178 405 35.6 14.4 2460 2189 170 540 36.1 19.5 3152 2790 161 BXRE-50C1001-C-7x 70 180 33.2 6.0 1189 1061 199 240 34.0 8.2 1557 1384 191 360 34.8 12.5 2236 2012 178 540 35.6 19.2 3256 2828 169 720 36.1 26.0 4159 3560 160 BXRE-50E1001-B-7x 80 135 33.2 4.5 860 773 192 180 34.0 6.1 1127 1011 184 270 34.8 9.4 1613 1452 172 405 35.6 14.4 2367 2105 164 540 36.1 19.5 3032 2684 155 BXRE-50E1001-C-7x 80 180 33.2 6.0 1144 1020 191 240 34.0 8.2 1498 1331 184 360 34.8 12.5 2151 1936 172 540 35.6 19.2 3132 2721 163 720 36.1 26.0 4001 3425 154 BXRE-50G1001-B-7x 90 135 33.2 4.5 743 668 166 180 34.0 6.1 974 874 159 270 34.8 9.4 1394 1255 148 405 35.6 14.4 2046 1820 142 540 36.1 19.5 2621 2320 134 Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Performance at Commonly Used Drive Currents Table 5: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) BXRE-50G1001-C-7x 90 180 33.2 6.0 989 882 165 240 34.0 8.2 1295 1150 159 360 34.8 12.5 1859 1673 148 540 35.6 19.2 2707 2352 141 720 36.1 26.0 3458 2960 133 BXRE-57C1001-B-7x 70 135 33.2 4.5 869 781 194 180 34.0 6.1 1140 1022 186 270 34.8 9.4 1631 1468 174 405 35.6 14.4 2393 2129 166 540 36.1 19.5 3066 2714 157 BXRE-57C1001-C-7x 70 180 33.2 6.0 1156 1032 193 240 34.0 8.2 1515 1346 186 360 34.8 12.5 2175 1958 174 540 35.6 19.2 3167 2752 165 720 36.1 26.0 4046 3463 155 BXRE-57E1001-B-7x 80 135 33.2 4.5 826 742 184 180 34.0 6.1 1083 971 177 270 34.8 9.4 1549 1394 165 405 35.6 14.4 2273 2022 157 540 36.1 19.5 2912 2577 149 BXRE-57E1001-C-7x 80 180 33.2 6.0 1098 980 184 240 34.0 8.2 1439 1278 176 360 34.8 12.5 2066 1859 165 540 35.6 19.2 3008 2613 156 720 36.1 26.0 3843 3289 148 BXRE-65C1001-B-7x 70 135 33.2 4.5 869 781 194 180 34.0 6.1 1140 1022 186 270 34.8 9.4 1631 1468 174 405 35.6 14.4 2393 2129 166 540 36.1 19.5 3066 2714 157 BXRE-65C1001-C-7x 70 180 33.2 6.0 1156 1032 193 240 34.0 8.2 1515 1346 186 360 34.8 12.5 2175 1958 174 540 35.6 19.2 3167 2752 165 720 36.1 26.0 4046 3463 155 BXRE-65E1001-B-7x 80 135 33.2 4.5 835 751 186 180 34.0 6.1 1095 982 179 270 34.8 9.4 1568 1411 167 405 35.6 14.4 2300 2046 159 540 36.1 19.5 2946 2608 151 BXRE-65E1001-C-7x 80 180 33.2 6.0 1111 992 186 240 34.0 8.2 1456 1293 178 360 34.8 12.5 2090 1881 167 540 35.6 19.2 3044 2644 158 720 36.1 26.0 3888 3328 149 Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Electrical Characteristics

Notes for Table 6: 1. Parts are tested in pulsed conditions, Tc = 25°C. Pulse width is 10ms. 2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance. 3. Bridgelux maintains a tester tolerance of ± 0.10V on forward voltage measurements. 4. Typical coefficient of forward voltage tolerance is ± 0.1mV for nominal current. 5. Thermal resistance values are based from test data of a 3000K 80 CRI product. 6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal interface material used during testing is not included in the thermal resistance value. 7. Vf min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design and selection over the operating range of the product. 8. This product has been designed and manufactured per IEC 62031:2018. This product has passed dielectric withstand voltage testing at 1160 V. The working voltage designated for the insulation is 80V d.c. The maximum allowable voltage across the array must be determined in the end product application. Table 6: Electrical Characteristics Part Number Drive Current (mA) Forward Voltage Pulsed, Tc = 25ºC (V) 1, 2, 3, 8 Typical Coefficient of Forward Voltage4 ∆Vf/∆Tc (mV/ºC) Typical Thermal Resistance Junction to Case5,6 Rj-c (ºC/W) Driver Selection Voltages7 (V) Minimum Typical Maximum Vf Min. Hot Tc = 105ºC (V) Vf Max. Cold Tc = -40ºC (V) BXRE-xxx100x-B-7x BXRE-xxx100x-C-7x

Table 7: Eye Safety Risk Group (RG) Classifications Notes for Table 7: 1. Eye safety classification for the use of Bridgelux V Series LED arrays is in accordance with specification IEC/TR 62778: Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires. 2. For products classified as RG2 at 4000K, Ethr= 1847.5 lx. 3. For products classified as RG2 at 5000K Ethr= 1315.8 lx. 4. For products classified as RG2 at 6500K, Ethr= 1124.5 lx. 5. Please contact your Bridgelux sales representative for Ethr values at specific drive currents and CCTs not listed. Part Number Drive Current 5 (mA) CCT1,5 2700K/3000K 4000K2 5000K3 6500K4 BXRE-xxx100x-B-7x

270 RG1 RG1 RG1 RG1

405 RG1 RG1 RG1 RG2

540 RG1 RG1 RG2 RG2

360 RG1 RG1 RG1 RG2

720 RG1 RG2 RG2 RG2

LED Junction Temperature (Tj) 150°C Storage Temperature -40°C to +105°C Operating Case Temperature1 (Tc) 105°C Soldering Temperature2 300°C or lower for a maximum of 6 seconds BXRE-xxx100x-B-7x BXRE-xxx100x-C-7x Maximum Drive Current3 540mA 720mA Maximum Peak Pulsed Drive Current4 770mA 1030mA Maximum Reverse Voltage5 -60V -60V Table 8: Maximum Ratings Notes for Table 8: 1. For IEC 62717 requirement, please consult your Bridgelux sales representative. 2. Refer to Bridgelux Application Note AN101: Handling and Assembly of Bridgelux V Series LED Arrays. 3. Arrays may be driven at higher currents however lumen maintenance may be reduced. 4. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed current specified. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures. 5. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating provided for reference only.

Figure 18: Drawing for V10 LED Array Notes for Figure 18: 1. Drawings are not to scale. 2. Drawing dimensions are in millimeters. 3. Unless otherwise specified, tolerances are ±0.1mm. 4. Solder pad labeled “+” denotes positive contact. 5. Refer to Application Notes AN101 for product handling, mounting and heat sink recommendations. 6. The optical center of the LED Array is nominally defined by the mechanical center of the array to a tolerance of ± 0.2mm. 7. Bridgelux maintains a flatness of 0.10mm across the mounting surface of the array.

Bin Code 2000K 2700K 3000K1 3500K1 4000K1 ANSI Bin (for reference only) - (2580K - 2870K) (2870K - 3220K) (3220K - 3710K) (3710K - 4260K) 73 (3 SDCM) - (2651K - 2794K) (2968K - 3136K) (3369K - 3586K) (3851K - 4130K) 72 (2 SDCM) - (2674K - 2769K) (2995K - 3107K) (3404K - 3548K) (3895K - 4081K) Table 9: Warm and Neutral White xy Bin Coordinates and Associated Typical CCT Bin Code 5000K 5700K 6500K ANSI Bin (for reference only) (4745K - 5311K) (5312K - 6022K) (6022K - 7042K) 74 (4 SDCM) (4801K - 5282K) ((5395K - 5970K() (6200K - 6910K) 73 (3 SDCM) (4835K - 5215K) ((5460K - 5891K() (6279K - 6811K) Table 10: Cool White xy Bin Coordinates and Associated Typical CCT (product is hot targeted to Tc = 85°C) Notes for Table 9: 1. Color Binning information excludes Décor Series Class A products. Please contact your Bridgelux Sales Representative for more information. 2. Center Point for Decor Series Showcase. 3. Bridgelux maintains a tolerance of +/- 0.007 on x and y color coordinates in the CIE 1931 color Space. Figure 19: Warm and Neutral White Test Bins in xy Color Space Note: Pulsed Test Conditions, Tc = 25°C Figure 20: Cool White Test Bins in xy Color Space Note: Pulsed Test Conditions, Tc = 25°C 0.34 0.36 0.38 0.4 0.42 0.44 Y X

3 SDCM

2 SDCM

0.3 0.31 0.32 0.33 0.34 0.35 0.36 0.37 0.38 0.39 Y X

4 SDCM

Note for Table 10: 1. Bridgelux maintains a tolerance of +/- 0.007 on x and y color coordinates in the CIE 1931 color Space.

Figure 21: V10 Packaging Tube Notes for Figure 21: 1. Each tube holds 30 V10 COB arrays. 2. One tube is sealed in an anti-static bag. Four bags are placed in a shipping box. Depending on quantities ordered, a bigger shipping box, containing four boxes may be used to ship products. 3. Each bag and box is to be labeled as shown above. box are 58.7 x 13.3 x 7.9 cm

Figure 22: Gen. 7 Product Labeling Bridgelux COB arrays have laser markings on the back side of the substrate to help with product identification. In addition to the product identification markings, Bridgelux COB arrays also contain markings for internal Bridgelux manufacturing use only. The image below shows which markings are for customer use and which ones are for Bridgelux internal use only. The Bridgelux internal manufacturing markings are subject to change without notice, however these will not impact the form, function or performance of the COB array. Customer Use- 2D Barcode Scannable barcode provides product part number and other Bridgelux internal production information. Customer Use- Product part number 30E1000C 73 2F Customer Use- Vf Bin Code included to enable greater luminaire design flexibility. Refer to AN92 for bin code definitions. Internal Bin Code

Bridgelux has developed a comprehensive set of application notes and design resources to assist customers in successfully designing with the V Series product family of LED array products. For all available application notes visit www.bridgelux.com. Optical Source Models Optical source models and ray set files are available for all Bridgelux products. For a list of available formats, visit www.bridgelux.com. MINOR PRODUCT CHANGE POLICY The rigorous qualification testing on products offered by Bridgelux provides performance assurance. Slight cosmetic changes that do not affect form, fit, or function may occur as Bridgelux continues product optimization. CAUTION: CHEMICAL EXPOSURE HAZARD Exposure to some chemicals commonly used in luminaire manufacturing and assembly can cause damage to the LED array. Please consult Bridgelux CAUTION: RISK OF BURN Do not touch the V Series LED array during operation. Allow the array to cool for a sufficient period of time before handling. The V Series LED array may reach elevated temperatures such that could burn skin when touched. 3D CAD Models Three dimensional CAD models depicting the product outline of all Bridgelux V Series LED arrays are available in both IGS and STEP formats. Please contact your Bridgelux sales representative for assistance. LM80 LM80 testing has been completed and the LM80 report is now available. Please contact your Bridgelux sales representative for LM-80 report. STANDARD TEST CONDITIONS Unless otherwise stated, array testing is performed at the nominal drive current. CAUTION CONTACT WITH LIGHT EMITTING SURFACE (LES) Avoid any contact with the LES. Do not touch the LES of the LED array or apply stress to the LES (yellow phosphor resin area). Contact may cause damage to the LED array. Optics and reflectors must not be mounted in contact with the LES (yellow phosphor resin area).

About Bridgelux: Bridging Light and Life™ © 2021 Bridgelux, Inc. All rights reserved. Product specifications are subject to change without notice. Bridgelux, the Bridgelux stylized logo design, Vero, V Series and V Series HD are registered trademarks, and Decor Series is a trademark of Bridgelux, Inc. All other trademarks are the property of their respective owners. Bridgelux Gen 7 V10 Array Series Product Data Sheet DS100 Rev. T (11/2022)

46410 Fremont Boulevard

Fremont, CA 94538 U.S.A. Tel (925) 583-8400 www.bridgelux.com At Bridgelux, we help companies, industries and people experience the power and possibility of light. Since 2002, we’ve designed LED solutions that are high performing, energy efficient, cost effective and easy to integrate. Our focus is on light’s impact on human behavior, delivering products that create better environments, experiences and returns—both experiential and financial. And our patented technology drives new platforms for commercial and industrial luminaires. For more information about the company, please visit bridgelux.com twitter.com/Bridgelux facebook.com/Bridgelux youtube.com/user/Bridgelux linkedin.com/company/bridgelux-inc-_2 WeChat ID: BridgeluxInChina