DRTX24D06X_17 CRYDOM | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 7

Technical content

DataSheetSolid State Relay Timer SeriesOneDR Timer

  • 6 Amp AC and DC rated output
  • Compact size (11mm wide)
  • Dual SCR or MOSFET output
  • AC/DC control
  • Zero-crossing (resistive loads) or random-fire (inductive loads) AC output
  • Timer status LED indicator
  • UL listed, HP rated
  • 8 Industry standard fuctions (A/At, B, C, D/Di, H/Ht, L/Li, Ac and Bw) PRODUCT SELECTION Control Voltage DC OutputAC Output 12-24 VAC/DC DRTx24D06x DRTx06D06 90-140 VAC/DC DRTx24B06x 180-280 VAC/DC DRTx24A06x AVAILABLE OPTIONS DRT Series Operating Voltage 06: 60 VDC 24: 280 VAC Rated Load Current 06: 6 Amps Control Voltage D: 12-24 VAC/DC A: 180-240 VAC/DC B: 90-140 VAC/DC Timing Function A: A/At, Delay on Make B: Single Shot C: Delay on Break H: H/Ht, Interval L: L/Li, Repeat Cycle U: Multifunction (A/At, H/Ht, D/Di, B, C, Ac & Bw) Switching Type (24 suffix only) Blank: Zero Voltage Turn-On R: Random Turn-On

0624 DA R

Required for valid part number For options only and not required for valid part number OUTPUT SPECIFICATIONS (1) DRTx06DRTx24Description Operating Voltage 24-280 VAC (47-440Hz) 1-48 VDC Transient Overvoltage [Vpk] 600 60 VDC Rated Load Current (2) 6 Arms 6 A Rated Load Current {UL508 Motor Controller} (2) [Arms] 3.6 Arms - Minimum Load Current 150 mArms 2.5 mA Maximum Off-State Leakage Current @ Rated Voltage 0.1 mArms 0.25 mA Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (3) 500 - Maximum Surge Current (AC output 1 cycle. DC output 10ms) 285/300 Apk (50/60Hz) 60 A Maximum I²t for Fusing [A² sec] 410/375 (50/60Hz) - Maximum On-State Voltage Drop @ Rated Current [Vpk] 1.3 0.3 VDC Maximum On-State Resistance (RDS-ON) [Ohms] - 0.034 HP rating UL 508/IEC60947[HP (KW)]: 240 VAC 1/3 (0.24) - IEC 62314 LC-A [FLA] 6 A - IEC 62314 LC-B [Kw] 0.24 - Wire Size min/max (solid/stranded) [AWG/ IEC mm²] (4) 22/12 [0.33/3.31] 22/12 [0.33/3.31] Output Terminal Screw Torque [in lb (Nm)] 7.0 (0.8) 7.0 (0.8) Not all part number combinations are available. Contact Crydom Technical Support for information on the availability of a specific part number. Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice.

DataSheetSolid State Relay Timer Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. INPUT SPECIFICATIONS (1) DRTx24B06DRTx24A06DRTxxxD06Description Control Voltage Range 12-24 VAC/DC 180-280 VAC/DC 90-140 VAC/DC Must Turn-Off Voltage 1 VAC/DC 20 VAC/DC 10 VAC/DC Nominal Input Impedance 2K Ohms(7) 25K ohms 12K ohms LED Status Indicator (Color) Yes (green) Yes (green) Yes (green) Maximum turn-on/off time See note (9) See note (9) See note (9) GENERAL SPECIFICATIONS ParametersDescription Dielectric Strength, Input/Output/Base (50/60Hz) 3750 Vrms (8) Minimum Insulation Resistance (@ 500 VDC) 109 Ohm Maximum Capacitance, Input/Output 10 pF Ambient Operating Temperature Range -30 to 80 °C Ambient Storage Temperature Range -40 to 125 °C Weight (typical) 1.76 oz (50 g) Housing Material UL 94 V0 Self-extinguishing Terminal Finish Sulfamate Nickel Humidity 5 - 85% Non condensing RoHS Exemption #’s 5(a), 7(a), 7(c)-I WIRING DIAGRAM INPUT CONTROL Load Y1+3/A1 4/A2 +1/L1 2/T1 AC Output TIMER Status Indicator (+ / ) (– / ) ( ) ( ) (10) INPUT CONTROL Load Y1+3/A1 4/A2 +1/L1 2/T1 DC Output TIMER Status Indicator (+ / ) (– / ) ( + ) ( – ) Load Load AC/DC CONTROL VOLTAGE (Input) AC/DC SUPPLY (OUTPUT)

DataSheetSolid State Relay Timer Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. TIMER SETTINGS & RANGES Timer Settings Identification Timing Function U Multifunction [A/At, H/Ht, D/Di, B, C, Ac, Bw] L Repeat Cycle A Delay on Make H Interval B Single Shot C Delay on Break 4 3 4 3 9 10 4 3 4 3 INPUT STATUS 10h 10m 100h 1s10s1m Ac C DiBw A HB 10h 10m 100h 1s10s1m 10h 10m 100h 1s10s1m 10h 10m 100h 1s10s1m Range Function Fine Adjustment Fine Adjustment Fine AdjustmentRange Flat side indicates selection Front ViewSide View T on T off 10 s 1 min 10 min 1 h 10 h 100 h 0.1 s to 1 s 1 s to 10 s 0.1 min to 1 min 1 min to 10 min 0.1 h to 1 h 1 h to 10 h 10 h to 100 h Timing Ranges (11) Identification Timing Range GENERAL NOTES (1) All parameters at 25°C unless otherwise specified. (2) See derating curves. (3) Off-State dv/dt test method per EIA/NARM standard RD-443, paragraph 13.11.1 (4) For UL Listing, must use wire rated @ 75°C. (5) For DC output model minimum current spec is 15.7/12.4ma (AC/DC). (6) For DC output model maximum current spec is 27.9/20.3ma (AC/DC). (7) For DC output mode, spec is 1K. (8) For DC output model, spec is 2500V. (9) Activation Time = 65ms / Deactivation Time = 100 ms. (10) Inductive loads must be diode suppressed to prevent damage to output. (11) Timing accuracy ± 10%. Additional functions and time ranges are also available, please contact your local authorized Crydom Distributor, Representative or Crydom Sales office and request information about our custom products. (12) Do not apply a push force greater than 9.8N(2.2lbf) and Stop torque 4Ncm. (13) Do not apply a push/pull force greater than 5N(1.12lbf) and torque 20Nm.

DataSheetSolid State Relay Timer Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. MECHANICAL SPECIFICATIONS Tolerances: ±0.02 in / 0.5 mm All dimensions are in: inches [millimeters] 3.27 [83.0] 3.45 [87.7] 2.59 [65.9] 1.76 [44.8] 3.44 [87.3] INPUT 12-24 VDC General Use 60VDC/6Arms @40°C Ambient Temperature IND. CONT. EQ INPUT STATUS 4/A2 2/T1 DRTL06D06 +1/L1+3/A1 4WB8 SOLID STATE TIMER THERMAL DERATE INFORMATION 0 302010 40 50 60 70 80 Ambient Temperature (ºC) Load Current (Amps) Installed single unit, distance to adjacent components ≥ 11 mm Multiple Units No Spacing 2.02 [51.2] 0.44 [11.0] 2.87 [73.0] (12) (13)

DataSheetSolid State Relay Timer Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. T C L A T C L H T C L Y1B T C L T T T TDi C L T TAc T=t1+t2+t3 L t1 t2 t3 At C T=t1+t2+t3 C L t1 t2 t3 Y1Ht T C L Y1C T C L T T T TA1Y1D C L TTBw C L A1Y1 Ton Toff Ton ToffToff L Ton C L Toff Ton Toff Li LED Status by Function Function Control Voltage Y1 Timing Output State LED Status Notes A/At Delay On Make Off On On Off On On On Off On On On On Off On On On Off On On On On On Off On Off On Off On On Open Open Closed Closed Open Open Closed Open Open Open Open Closed Closed Open Open Closed Closed Open Open Off On Timed Out Off Off On Timed Out Off Off Off On Timed Out Off Off On Timed Out Off Off On Timed Out On Timed Out Off On Off On Off On Timed Out Off Off On Off Off On Off Off Off On On Off Off Off Off On Off Off On Off On Off Off On Off On/Off Off On/Off Off Off Long Flashes On Off Short Flashes Long Flashes Short Flashes Off Short Flashes On Long Flashes Short Flashes Off Short Flashes Long Flashes On Off Short Flashes Long Flashes Short Flashes Long Flashes Short Flashes Off Long Flashes Off Long Flashes/Short Flashes Off Long Flashes/Short Flashes Short Flashes H/Ht Interval D/Di Repeat Cycle L/Li Repeat Cycle B Single Shot C Delay On Break Ac Delay On Make / Delay On Break Bw At function is identical to the A function except when Y1 is connected to A1 timing is paused. When Y1 is removed timing resumes until relay times out. To reset timer remove control power. Ht function is identical to the H function except when Y1 is connected to A1 timing is paused. When Y1 is removed timing resumes until relay times out. To reset timer remove control power. Y1 switch can be momentary or maintained to A1. To reset timer after relay has timed out Y1 has to be opened. Y1 switch to A1 must be momentary for timing to begin. If during timing Y1 is closed again the time delay is reset and will begin again once Y1 is removed. Once timed out timer is reset and ready for the next cycle. Y1 to A1 switch can be momentary or maintained. If maintained until relay has timed out removing it will start timing again. If momentary and timers has timed out reapplying Y1 will start timing again. To start Delay on Make (A) timing connect Y1 to A1 and maintain until LED is on Solid then to start Delay on Break (c) portion remove Y1 until relay times out. Removing Y1 During (A ) portion or Connecting Y1 during (c) portion will reset time for that portion. To select between on time (Di) first or off time (D) first Y1 is connected. Default is On time (Di) first, for Off time (D) first connect Y1. Equal On/Off time. To select between on time (Li) first or off time (L) first Y1 is connected A1. Default is On time (Li) first, for Off time (L) first connect Y1 to A1. Time delay is independent of each other. LED STATUS FUNCTION AGENCY APPROVALS Designed in accordance with the requirements of IEC 62314 IEC 60068-2-6 : Vibration 0.35mm and 0.75mm Amplitutde over 10-55 Hz IEC 60068-2-27 : Shock 15G/11ms IEC 61000-4-2 : Electrostatic Discharge Level 3 IEC 61000-4-4 : Electrically Fast Transients Level 3 IEC 61000-4-5 : Electrical Surges Level 3 E116949 042517 IND. CONT. EQ. 4WB8

DataSheetSolid State Relay Timer Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / 危险 HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH.

  • Disconnect all power before installing or working with this equipment.
  • Verify all connections and replace all covers before turning on power. Failure to follow these instructions will result in death or serious injury. RIESGO DE DESCARGA ELECTRICA O EXPLOSION.
  • Desconectar todos los suministros de energia a este equipo antes de trabajar con este equipo.
  • Verificar todas las conexiones y colocar todas las tapas antes de energizer el equipo. El incumplimiento de estas instrucciones puede provocar la muerte o lesiones serias. RISQUE DE DESCHARGE ELECTRIQUE OU EXPLOSION
  • Eteindre toutes les sources d'énergie de cet appareil avant de travailler dessus de cet appareil
  • Vérifier tous connections, et remettre tous couverts en olace avant de mettre sous De non-suivi de ces instructions provoquera la mort ou des lésions sérieuses sérieuses. GEFAHR EINES ELEKTRISCHE N SCHLAGES ODER EINER EXPLOSION.
  • Stellen Sie jeglichen Strom ab, der dieses Gerät versorgt, bevor Sie an dem Gerät Arbeiten durchführen
  • Vor dem Drehen auf Energie alle Anschlüsse überprüfen und alle Abdeckungen ersetzen. Unterlassung dieser Anweisungen können zum Tode oder zu schweren Verletzungen führen. 存在电击、 爆炸或电弧 闪烁危险
  • 在操作此设 备之前请先 关闭电源。 若不遵守这些说明, 可能会导致严重的 人身伤害甚至死亡。 WARNING / AVERTISSEMENT / WARNUNG /ADVERTENCIA / AVVERTENZA / 警告 RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE
  • The product's side panels may be hot, allow the product to cool before touching.
  • Follow proper mounting instructions including torque values.
  • Do not allow liquids or foreign objects to enter this product. Failure to follow these instructions can result in serious injury, or equipment damage. RISQUE DE DOMMAGE MATERIEL ET DE SURCHAUFFE DU BOITIER
  • Les panneaux latéraux du produit peuvent être chauds. Laisser le produit refroidir avant de le toucher.
  • Respecter les consignes de montage, et notamment les couples de serrage.
  • Ne pas laisser pénétrer de liquide ni de corps étrangers à l'intérieur du produit. Le non-respect de cette directive peut entraîner, des lésions corporelles graves ou des dommages matériels. Die Nichtbeachtung dieser Anweisung kann Körperverletzung oder Materialschäden zur Folge haben. GEFAHR VON MATERIALSCHÄDEN UND GEHÄUSEERHITZUNG
  • Die Seitenwände können heiß sein. Lassen Sie das Produkt abkühlen, bevor Sie es berühren.
  • Beachten Sie die Montageanweisungen,
  • Führen Sie keine Flüssigkeiten oder Fremdkörper in das Produkt ein. Si no se respetan estas precauciones pueden producirse graves lesiones, daños materiales. RIESGO DE DAÑOS MATERIALES Y DE SOBRECALENTAMIENTO DE LA UNIDAD
  • Los paneles laterales del producto pueden estar calientes. Esperar que el producto se enfríe antes de tocarlo.
  • Respetar las instrucciones de montaje, y en particular los pares de apretado.
  • No dejar que penetren líquidos o cuerpos extraños en el producto. 如不能正确执行这些操作说明, 极有可能造成严重人体伤害或者设备的损坏。 材料损坏和高温外壳的危险性
  • 产品的一侧面板可能很热,在其冷却前请 不要触碰。
  • 遵照正确的安装说明,包括扭矩值。
  • 请勿让液体及其他异物进入本产品。 RISCHIO DI SCOSSA ELETTRICA O DELL’ESPLOSIONE.
  • Spenga tutta l'alimentazione che fornisce questa apparecchiatura prima di lavorare a questa apparecchiatura
  • Verificare tutti i collegamenti e sostituire tutte le coperture prima dell’accensione L'omissione di queste istruzioni provocherà la morte o lesioni serie La mancata osservanza di questa precauzione può causare gravi rischi per l'incolumità personale o danni alle apparecchiature. RISCHIO DI DANNI MATERIALI E D'INVOLUCRO CALDO
  • I pannelli laterali dell'apparecchio possono scottare; lasciar quindi raffreddare il prodotto prima di toccarlo.
  • Seguire le istruzioni di montaggio corrette.
  • Non far entrare liquidi o oggetti estranei in questo apparecchio.

DataSheetSolid State Relay Timer Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. ANNEX - ENVIROMENTAL INFORMATION The environmental information disclosed in this annex including the EIP Pollution logo are in compliance with People’s Republic of China Electronic Industry Standard SJ/T11364 – 2006, Marking for Control of Pollution Caused by Electronic Information Products. Part Name Toxic or hazardous Substance and Elements Lead Mercury Cadmium Hexavalent Polybrominated Polybrominated (Pb) (Hg) (Cd) Chromium (Cr (VI)) biphenyls (PBB) diphenyl ethers (PBDE) Semiconductor die Solder 附件 - 环保信息 此附件所标示的包括电子信息产品污染图标的环保信息符合中华人民共和国电子行业标准 SJ/T11364 - 2006, 电子信息产品污染控制标识要求。 有毒有害物质或元素件部 名称 铅 汞 镉 六价铬 多溴联苯 多溴二苯醚 (Pb) (Hg) (Cd) (Cr (VI)) (PBB) (PBDE) 半导体芯片 焊接点